Loading...
HomeMy WebLinkAboutNC0070289_Compliance Evaluation Inspection_20181031 (2)ROY- COOPER NORTH CAROLINA Catiarnar EizvbT mental Quafrty ECHAEL S_ RE _^X 3aorafw:r LLNDA CT,-LPEPPER IntsriFn Diracmr Certified Mail # 7016 1370 0000 2591 1094 Return Receipt Requested October 30, 2018 Wayne Huntley Stones Throw Homeowners Association PO Box 690725 Charlotte, NC 28227 SUBJECT: NOTICE OF VIOLATION & INTENT TO ASSESS CIVIL PENALTY Tracking Number: NOV-2018-PC-0403 Permit No. NCO070289 Ridgewood Farms Subdivision Cabarrus County Dear Mr. Huntley: The North Carolina Division of Water Resources conducted an inspection of the Ridgewood Farms Subdivision on October 22, 2018. This inspection was conducted to verify that the facility is operating in compliance with the conditions and limitations specified in NPDES WW Permit No. NC0070289. A summary of the findings and comments noted during the inspection are provided in the enclosed copy of the inspection report. The Compliance Evaluation inspection was conducted by Division of Water Resources staff from the Mooresville Regional Office. The following violation(s) were noted during the inspection: Inspection Area Description of Violation Permit As of the inspection date, no application for permit renewal has been received. The current permit expires November 30, 2018. Please be advised that in accordance with North Carolina Administrative Code (NCAC) T15A: 02H .0211, PERMIT RENEWALS, Request for permit renewals are to be submitted to the Director at least 180 days prior to expiration... D-EQ§ NFn� G1Wf North Carolina Department of Environmental Quality I Division of Water Resources 610 East Center Avenue, Suite 301, Mooresville, NC 28115 704-663-1699 Inspection Area Description of Violation Aeration Basins Diffusers in aeration tank appeared to be broken or missing. MLSS did not have a smooth roll and was devoid of fine bubbles. Oxygen transfer appeared to be ineffective and wasting energy. Diffusers should be repaired or replaced. Sludge Handling Disposal Hole rusted in bulkhead between aeration basin and waste sludge tank. Aerobic Digester Top of bulkhead between digester and aeration basin has rusted out and bulkhead may collapse if digester is pumped all the way down. The rusted -out hole in bulkhead makes it ineffective to waste and dewater sludge at this facility. In addition, the issues below must also be addressed: Compliance Issue(s): Please be advised that in accordance with NCAC T15A: 02H .0211, Permit Renewals, permit renewal should be submitted at least 180 days prior to expiration. Permit renewal application and required fees should be completed and sent to the Division. If you should have any questions regarding this process you may contact Mr. Derek Denard in Raleigh at 919-707-3618. Please also note that in accordance with your NPDES Permit, Number NCO070289, Part II, Section C. Operation and Maintenance of Pollution Controls, 2., The Permittee shall at all times properly operate and maintain all facilities and systems of treatment and control (and related appurtenances) which are installed or used by the Permittee to achieve compliance with Conditions of the permit. Therefore, it is necessary to perform repairs to diffusers and sludge waste tank for treatment facility to operate at optimal efficiency. A Notice of Violation/Intent to Issue Civil Penalty is being issued for the noted violation of North Carolina General Statute (G.S.) 143-215.1 and the facility's NPDES WW Permit. Pursuant to G.S. 143-215.6A, a civil penalty of not more than twenty-five thousand dollars ($25,000.00) may be assessed against any person who violates or fails to act in accordance with the terms, conditions, or requirements of any permit issued pursuant to G.S. 143-215.1. If you wish to provide additional information regarding the noted violation, request technical assistance, or discuss overall compliance please respond in writing within ten (10) business day after receipt of this Notice. A review of your response will be considered along with any additional information provided. You will then be notified of any civil penalties that may be assessed regarding the violations. If no response is received in this Office within the 10-day period, a civil penalty assessment may be prepared. Remedial actions should have already been taken to correct this problem and prevent further occurrences in the future. The Division of Water Resources may pursue enforcement action for this and any additional violations of State law. If the violations are of a continuing nature, not related to operation and/or maintenance problems, and you anticipate remedial construction activities, then you may wish to consider applying for a Special Order by Consent. Reminder: Pursuant to Permit Condition 6 in Section E, the Permittee is required to verbally notify the Regional Office as soon as possible, not to exceed 24 hours, from first knowledge of any non-compliance at the facility including limit violations, bypasses of, or failure of a treatment unit. A written report may be required within 5 days if directed by Division staff. Prior notice should be given for anticipated or potential problems due to planned maintenance activities, taking units off-line, etc. D_EQ§ Ikys�. n NFn�w.e�W G1Wf� North Carolina Department of Environmental Quality I Division of Water Resources 610 East Center Avenue, Suite 301, Mooresville, NC 28115 704-663-1699 If you should have any questions, please do not hesitate to contact Roberto Scheller with the Water Quality Regional Operations Section in the Mooresville Regional Office at 704-663-1699. Sincerely, DocuSigned by: A14CC681AF27425... W. Corey Basinger, Regional Supervisor Water Quality Regional Operations Section Mooresville Regional Office Division of Water Resources, NCDEQ ATTACHMENTS Cc: WQS Mooresville Regional Office - Enforcement File NPDES Compliance/Enforcement Unit - Enforcement File D-EQ NFn�w�e�W G1Wf� North Carolina Department of Environmental Quality I Division of Water Resources 610 East Center Avenue, Suite 301, Mooresville, NC 28115 704-663-1699 United States Environmental Protection Agency Form Approved. EPA Washington, D.C. 20460 OMB No. 2040-0057 Water Compliance Inspection Report Approval expires 8-31-98 Section A: National Data System Coding (i.e., PCS) Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type 1 IN I 2 15 I 3 I NCO070289 111 12 I 18/01/22 I17 18 I S I 19 I G I 201 I 211111 1 1 I I I I II I I I I I I I I I I I I 1 I I I I I I I I I I II I I I I I f6 Inspection Work Days Facility Self -Monitoring Evaluation Rating B1 QA ---------------------- Reserved ------------------- 671 70 I2 71 I tyI 72 I r I 73 I I 174 751 I I I I I I I80 uI I I i Section B: Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include Entry Time/Date Permit Effective Date POTW name and NPDES oermit Number) 10:OOAM 18/01/22 14/02/01 Ridgewood Farms Subdivision Olde Creek Trl Exit Time/Date Permit Expiration Date Concord NC 28025 11:03AM 18/01/22 18/11/30 Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) Other Facility Data Kellie H Hedrick/ORC/980-202-2377/ Name, Address of Responsible Official/Title/Phone and Fax Number Contacted Wayne Huntley,PO Box 690725 Charlotte INC 28227//704-455-5463/ No Section C: Areas Evaluated During Inspection (Check only those areas evaluated) Permit Flow Measurement Operations & Maintenance Records/Reports Self -Monitoring Program Sludge Handling Disposal Facility Site Review Effluent/Receiving Waters Laboratory Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s) and Signature(s) of Inspector(s) Agency/Office/Phone and Fax Numbers Date DocuSigned by: - - SQL MRO WQ//252-946-6481/ 10/30/2018 Roberto Scheller Cj91C2A007838943E— Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date W. Corey Basinger Division of Water Quality//704-2' EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete. DocuSigned by: e� 10/30/2018 AlaccsalAi=vazs... Page# NPDES yr/mo/day Inspection Type NCO070289 I11 121 18/01/22 117 18 JCJ Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) As of date of this inspection the Division has not received a renewal permit application. Diffusers in aeration basin require repair or replacement. Sludge waste tank requires repair of replacement. Although at the time of inspection the ORC was doing an exceedingly good job of operating the subject wastewater treatment plant (WWTP). The above noted plant deficiencies will hamper plant performance and the ability of operator to effectively and efficiently operate WWTP at peak performance. Page# Permit: NCO070289 Owner - Facility: Ridgewood Farms Subdivision Inspection Date: 01/22/2018 Inspection Type: Compliance Evaluation Permit Yes No NA NE (If the present permit expires in 6 months or less). Has the permittee submitted a new ❑ 0 ❑ ❑ application? Is the facility as described in the permit? 0 ❑ ❑ ❑ # Are there any special conditions for the permit? ❑ 0 ❑ ❑ Is access to the plant site restricted to the general public? 0 ❑ ❑ ❑ Is the inspector granted access to all areas for inspection? 0 ❑ ❑ ❑ Comment: As of the inspection date, no application for permit renewal has been received. The current permit expires November 30, 2018. Please be advised that in accordance with North Carolina Administrative Code T15A: 02H .0211, PERMIT RENEWALS, Request for permit renewals are to be submitted to the Director at least 180 days proir to expiration... Laboratory Yes No NA NE Are field parameters performed by certified personnel or laboratory? 0 ❑ ❑ ❑ Are all other parameters(excluding field parameters) performed by a certified lab? 0 ❑ ❑ ❑ # Is the facility using a contract lab? M ❑ ❑ ❑ # Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees 0 ❑ ❑ ❑ Celsius)? Incubator (Fecal Coliform) set to 44.5 degrees Celsius+/- 0.2 degrees? ❑ ❑ ❑ Incubator (BOD) set to 20.0 degrees Celsius +/- 1.0 degrees? ❑ ❑ ❑ Comment: K&W Laboratories (Certification #559) is used as contract lab. Field Darameters are conducted under field Certification #5695. Operations & Maintenance Yes No NA NE Is the plant generally clean with acceptable housekeeping? ❑ ❑ ❑ Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable ❑ ❑ ❑ Solids, pH, DO, Sludge Judge, and other that are applicable? Comment: At time of insepction 30 minute settleability test was on going and apx 40 minutes had elapased. MLSS had settled to a defined sludge blanket with clear supernatant above. Bar Screens Yes No NA NE Type of bar screen a.Manual b.Mechanical ❑ Are the bars adequately screening debris? 0 ❑ ❑ ❑ Is the screen free of excessive debris? 0 ❑ ❑ ❑ Is disposal of screening in compliance? 0 ❑ ❑ ❑ Page# 3 Permit: NCO070289 Inspection Date: 01/22/2018 Bar Screens Owner - Facility: Ridgewood Farms Subdivision Inspection Type: Compliance Evaluation Yes No NA NE Is the unit in good condition? 0 ❑ ❑ ❑ Comment: Old bar screen has been replaced. New bar screen appeared to be operating properly. Aeration Basins Yes No NA NE Mode of operation Ext. Air Type of aeration system Diffused Is the basin free of dead spots? ❑ 0 ❑ ❑ Are surface aerators and mixers operational? ❑ ❑ 0 ❑ Are the diffusers operational? 0 ❑ ❑ ❑ Is the foam the proper color for the treatment process? E ❑ ❑ ❑ Does the foam cover less than 25% of the basin's surface? 0 ❑ ❑ ❑ Is the DO level acceptable? ❑ ❑ ❑ Is the DO level acceptable?(1.0 to 3.0 mg/1) ❑ ❑ ❑ Comment: Diffusers in areation tank appeared to be broken or missing. MLSS did not have a smoth roll and was devoid of fine bubbles. Oxygen transfer appeared to ineffective and wasting energy. Diffusers should be repaired or replaced. Secondary Clarifier Is the clarifier free of black and odorous wastewater? Is the site free of excessive buildup of solids in center well of circular clarifier? Are weirs level? Is the site free of weir blockage? Is the site free of evidence of short-circuiting? Is scum removal adequate? Is the site free of excessive floating sludge? Is the drive unit operational? Is the return rate acceptable (low turbulence)? Is the overflow clear of excessive solids/pin floc? Is the sludge blanket level acceptable? (Approximately'/4 of the sidewall depth) Comment: Effluent from secondary clarifier was clear with few visible suspended solids. Disinfection -Tablet Are tablet chlorinators operational? Are the tablets the proper size and type? Yes No NA NE ■ ❑ ❑ ❑ ■ ❑ ❑ ❑ ■ ❑ ❑ ❑ ■ ❑ ❑ ❑ ■ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ Yes No NA NE ■ ❑ ❑ ❑ ❑ ❑ ❑ Page# 4 Permit: NCO070289 Owner - Facility: Ridgewood Farms Subdivision Inspection Date: 01/22/2018 Inspection Type: Compliance Evaluation Disinfection -Tablet Yes No NA NE Number of tubes in use? 4 Is the level of chlorine residual acceptable? 0 ❑ ❑ ❑ Is the contact chamber free of growth, or sludge buildup? 0 ❑ ❑ ❑ Is there chlorine residual prior to de -chlorination? 0 ❑ ❑ ❑ Comment: De -chlorination Yes No NA NE Type of system ? Tablet Is the feed ratio proportional to chlorine amount (1 to 1)? M ❑ ❑ ❑ Is storage appropriate for cylinders? ❑ ❑ 0 ❑ # Is de -chlorination substance stored away from chlorine containers? ❑ ❑ ❑ Comment: Are the tablets the proper size and type? 0 ❑ ❑ ❑ Are tablet de -chlorinators operational? 0 ❑ ❑ ❑ Number of tubes in use? 4 Comment: Flow Measurement - Effluent Yes No NA NE # Is flow meter used for reporting? 0 ❑ ❑ ❑ Is flow meter calibrated annually? 0 ❑ ❑ ❑ Is the flow meter operational? 0 ❑ ❑ ❑ (If units are separated) Does the chart recorder match the flow meter? 0 ❑ ❑ ❑ Comment: Flow meter was calibrated by Delta Systems Environmental. Next calibration due November 2018. Effluent Sampling Is composite sampling flow proportional? Is sample collected below all treatment units? Is proper volume collected? Is the tubing clean? # Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees Celsius)? Is the facility sampling performed as required by the permit (frequency, sampling type representative)? Yes No NA NE ■ ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ ■ ❑ ❑ ❑ ■ ❑ ❑ ❑ Page# 5 Permit: NCO070289 Owner - Facility: Ridgewood Farms Subdivision Inspection Date: 01/22/2018 Inspection Type: Compliance Evaluation Effluent Sampling Yes No NA NE Comment: At time of inspection effluent sampler storage was noted at 3 degrees Celsius. Effluent Pipe Yes No NA NE Is right of way to the outfall properly maintained? 0 ❑ ❑ ❑ Are the receiving water free of foam other than trace amounts and other debris? 0 ❑ ❑ ❑ If effluent (diffuser pipes are required) are they operating properly? ❑ ❑ 0 ❑ Comment: At time of inspection the discharge point effluent was clear with no visible solids. Foam being generated at point of discharge disipated 20 feet downstream. Aerobic Digester Yes No NA NE Is the capacity adequate? ❑ 0 ❑ ❑ Is the mixing adequate? ❑ 0 ❑ ❑ Is the site free of excessive foaming in the tank? ❑ ❑ 0 ❑ # Is the odor acceptable? ❑ ❑ 0 ❑ # Is tankage available for properly waste sludge? ❑ 0 ❑ ❑ Comment: Top of bulkhead between digester and aeration basin has rusted out and bulkhead may collapse if digester is pumped all the way down. The rusted out hole in bulkhead makes it ineffective to waste and dewater sludge at this facility. Page# 6