Loading...
HomeMy WebLinkAboutWQ0040398_Application (FTSE)_20180814State of North Carolina Department of Environmental Quality DWR Division of Water Resources I5A NCAC 02T .0300 — FAST TRACK SEWER SYSTEM EXTENSION APPLICATION Division of Water Resources FTA 04-16 & SUPPORTING DOCUMENTATION rr r� Application Number: U Q L103 i S oo be completed by DWR) J fI All items must be completed or the application will be returned 1. APPLICANT INFORMATION: -� I. Applicant's name: Johnston County Public Utilities (company, municipality, HOA, utility, etc.) 2. Applicant type: ❑ Individual ❑ Corporation ❑ General Partnership ❑ Privately -Owned Public Utility ❑ Federal ® State/County ❑ Municipal ❑ Other 3. Signature authority's name: Chandra C. Farmer. PE per 15A NCAC 02T .0106(b) Title: Public Utility Director Y. 4. Applicant's mailing address: P.O. Box 2263 O City: Smithfield State: NC Zip: 27577- 5. Applicant's contact information: Phone number: (919) 989-5075 Email Address: chandra.farmer@iohnstonnc.com II. PROJECT INFORMATION: 1. Project name: McGee's Crossroads Sewer Upgrade Phase_2B 2. Application/Project status: ® Proposed (New Permit) ❑ Existing Permit/Project If a modification, provide the existing permit number: WQ00 _ and issued date: If new construction but part of a master plan, provide the existing permit number: WQ00_ 3. County where project is located: Johnston 4. Approximate Coordinates (Decimal Degrees): Latitude: 35.54783 Longitude:-78.54074 5. Parcel ID (if applicable): (or Parcel ID to closest downstream sewer) III. CONSULTANT INFORMATION: I. Professional Engineer: Jamie Guerrero, PE License Number: 034417 Firm: Morris and Ritchie Associates of NC PC Mailing address: 5605 Chapel Hill Road, Suite 112 City. Raleigh State: NC Zip: 27607- Phone number: (984) 200-2103 Email Address: jauerrero(@mragta.com IV. WASTEWATER TREATMENT FACILITY (WWTF) INFORMATION: 1. Facility Name: Central Johnston County WWTF Permit Number: NCO030716 Owner Name: Johnston County Public Utilities A- V. RECEIVING DOWNSTREAM SEWER INFORMATION (if different than WWTF): 1. Permit Number(s): WQ0020340 Downstream (Receiving) Sewer Size: N:A inch Landfill Equalization Facility stem W1dC Collection System rrnk Numbers ifapplicable): WQCS00060 Owner Name(s): Johnston County Public Utilities FORM: FTA 04-I6 Pagel of 5 VI. GENERAL REQUIREMENTS I. If the Applicant is a Privately -Owned Public Utility, has a Certificate of Public Convenience and Necessity been attached? [:]Yes []No N'A See t O-11ai r 2. If the Applicant is a Developer of lots to be sold, has a Dcvcluper's Operational Agreement 1FORM: DE V) been attached? ❑ Ycs ❑No ON. -:A 3. If the Applicant is a Ilome Prupert-Clwiiers' Associati❑n_hz3s.,in Qperatiornul A�=mcmcnr (FORM: 140AI been attached? ❑ Yes ❑No XiA 4. Origin of wastewater: (check all that apply): ❑ Residential Owned ❑ Retail (stores, centers, malls) ❑ Car Wash ❑ Residential Leased ❑ Retail with food preparation/service ❑ Hotel and/or Motels ❑ School!' preschool / day care ❑ Medical!" dental i veterinary facilities ❑ Swimming Pool Clubhouse ❑ Food and drink facilities ❑ Church ❑ Swimming Pool/Filter Backwash ❑ Businesses 1 offices / factories ❑ Nursing Home ❑ Other (Explain in Attachment) 5. Nature of wastewater: % DomesticlCommcrcial % Commercial % Industrial (See, 15A NCAC 021 _0103f20) �Is there a Pretreatment Program in effect? ❑ Yes ❑ No 6. Hasa flow reduction been approved under 1.5A NCAC 02T .01 1 �JL? [:]Yes []No t If yes, Provide a copy of flow reduction aporeval letter 7. Summarize wastewater generated by project: Establishment Type (see k1L.011 Daily Design Flow'" No. of Units Flow gall GPD gall GAD gall GPD gall GPD gall GPD gall GPD 7olal GPD a See 15A NCAC 02T .01 14(b), (d), (c)(.1) and (c1121 for caveats to wastewater design flow rates (i.e., minimum flow per dwelling; proposed unknown non-residential development uses; public access facilities located near high public use areas; and residential property located south or cast of the Atlantic Intracoastal Waterway to be used as vacation rentals as defined in Q.S. 42A4). b Per 15A NCAC 02T .0114(c), design flow rates for establishments not identified [in table .15A NCAC 02'r.01141 shall be determined using available flow data, water using fixtures, occupancy or operation patterns, and other measured data. 8. Wastewater generated by project: 0 GPD (per )5A N Z C 02T .0l 14) D Do not include future flows or previously permitted allocations If permitted flow is zero, indicate why: ® Pump Station o ravity Sewer here flow will be permitted in subsequent permits that connect to this line ❑ Flow has already been allocated in Permit Number: ® Rehabilitation or replacement of existing sewer with no new flow expected ❑ Other (Explain): FORM: FTA 04-16 Page 2 of 5 VI1. GRAVITY SEWER DESIGN CRITERIA (If Applicable) - 02T .0305 & MDC(Gravity Sewers 1. Summarize gravity sewer to be permitted: Size (inches) Length (feet) Material 27 2,624 SDR-35 27 5,615 SDR-26 dF i- Section II & III of the MDC for Permitting of Gravity Sewers contains information related to design criteria D Section III contains information related to minimum slopes for gravity sewer(s) Oversizing lines to meet minimum slope requirement is not allowed and a violation of the MDC VIII. PUMP STATION DESIGN CRITERIA (If Applicable) — 02T .0305 & MDC(Pump Stations/Force Mains): COMPLETE FOR EACH PUMP STATION INCLUDED IN THIS PROJECT 1. Pump station number or name: 2. Approximate Coordinates (Decimal Degrees): Latitude: _ . Longitude: -� 3. Design flow of the pump station: millions gallons per day (firm capacity) 4. Operational point(s) of the pump(s): gallons per minute at — feet total dynamic head (TDH) 5. Summarize the force main to be permitted (for this Pump Station): Size (inches) Length (feet) Material 6. Power reliability in accordance with 15A NCAC 02T .0305 h I : ❑ Standby power source or pump with automatic activation and telemetry - 15A NCAC 02T .0305(h)(1)(B), Required for all pump stations with an average daily flow greater than or equal to 15,000 gallons per day Must be permanent to facility Or if the pump station has an average daily flow less than 15,000 gallons per day: ❑ Portable power source with manual activation, quick -connection receptacle and telemetry - 15A NCAC 02T .0305(h)(1)(C) or ❑ Portable pumping unit with plugged emergency pump connection and telemetry - I5A NCAC 02T .0305(h)(1)(C): z It shall be demonstrated to the Division that the portable source is owned or contracted by the applicant (draft agreement) and is compatible with the station. i- If the portable power source or pump is dedicated to multiple pump stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump, including travel timeframes, shall be provided in the case of a multiple station power outage. FORM: FTA 04-16 Page 3 of 5 IX. SETBACKS & SEPARATIONS - (02B .0200 & 15A NCAC 02T .0305(f)): I. Does the project comply with all separations found in 15A NCAC 0'2T .0305(o & (9-) ® Yes ❑ No 15A NCAC 02T.0305(f) contains minimum separations that shall he nrnvided far sewer svoemv Setback Parameter* Separation Required Storm sewers and other utilities not listed below (vertical) 24 inches Water mains (vertical -water over sewer including in benched trenches) 18 inches Water mains (horizontal) 10 feet Reclaimed water lines (vertical - reclaimed over sewer) 18 inches Reclaimed water lines (horizontal - reclaimed over sewer) 2 feet **Any private or public water supply source, including any wells, WS-I waters of Class I or Class II impounded reservoirs used as a source of drinking water 100 feet **Waters classified WS (except WS-I or WS-V), B, SA, ORW, HQW, or SB from normal high water (or tide elevation) and wetlands (sec item IX.2) 50 feet **Any other stream, lake, impoundment, or ground water Iowering and surface drainage ditches 10 feet Any building foundation 5 feet Any basement 10 feet Top slope of embankment or cuts of 2 feet or more vertical height 10 feet Drainage s stems and interce for drains 5 feet Any swimming pools 10 feet Final earth grade (vertical) 36 inches D I5A NCAC 02T.0305(e) contains alternatives where separations in 02T.0305(f1 cannot be achieved. > **Stream classifications can be identified using the Division's NC Surfacc Water Classifications webRai,c If noncompliance with 02T.0305 origh see Section X of this application 2. Does the project comply with separation requirements for wetlands? (50 feet of separation) csA No ❑ N"A Seethe Division's draft separation requirements for situations where separation cannot be mec 4 4p a FA4) �p r No variance is required if the alternative design criteria specified is utilized in design and construction As built documents should reference the location of areas effected 3. Does the project comply with setbacks found in the river basin rules per 15A NCAC 02B .0200? ®Yes ❑ No ❑ N A z This would include Trout Buffered Streams per 15A NCAC 213.0202 4. Does the project require coverage. -authorization under a 404 Nationwide or ® Yes ❑ No individual permits or 401 Water Quality Certifications? D Information can be obtained from the 401 & Buffer Pcrmiuint* Rran clt 5. Does project comply with 15A NCAC 02T.0105(c)(6) (additional permitslcertifications)? ® Yes ❑ No Per 15A NCAC 02T.0 I 05-WL61, directly related environmental permits or certification applications are being prepared, have been applied for, or have been obtained. Issuance of this permit is contingent on issuance of dependent permits (erosion and sedimentation control plans, stormwater management plans, etc.). 6. Does this project include any sewer collection lines that are deemed "high -priority?" Per 15A NC -AG 02T,0402, "high -priority sewer" means "any aerial sewer, sewer contacting surface waters, siphon, or sewer positioned parallel to streambanks that is subject to erosion that undermines or deteriorates the sewer. [:]Yes ® No ❑ N.-'A If yes, include an attachment with details for each line, including type (aerial line, size, material, and location). High priority lines shall be inspected by the permittee or its representative at least once every six -months and inspections documented per 15A NCAC 02T.0403(a)(5) or the permitee's individual System -Wide Collection permit. FORM: FTA 04-16 Page 4 of 5 ;Jkr4s '-oO X. CERTIFICATIONS: I. Does the submitted system comply with 15A NCAC 02T, the Minimum Design _Criteria.for thc.Permittinr, of Pump Stations arW fte Mains flatest version), and the Gravity Sewer Minimum Design C'ritcria. lgicst version as applicable? ® Yes ❑ No If No, complete and submit the Variance/Alternative Design Request application (VADC 10-14) and supporting documents for review. Approval of the re nest is required prior to submittal of the Fast Track Application and supporting documents. 2. Professional Engineer's Certification: -attest that this application for Engineer's name from Application Item 111.1.) has been reviewed by me and is accurate, complete and consistent with the information supplied in the plans, specifications, engineering calculations, and all other supporting documentation to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers (latest version), and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains (latest version). Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. NOTE - In accordance with General Statutes 143-215.6A and 143-215.613, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed S 10,000, as well as civil penalties up to S25,000 per violation. North Carolina Professional Engineer's seal, signature, and date: 3. Applicant's Certification per I SA NCAC 02T .0106(b): I, A* (Signature Authority's name & title from Application Item I.3.) i ............ I .... . . ..... _- ------ _.... ,,��IIIIIIIk�II r A C • SEAL p = 034417 ! d TABU r • attest that this application for has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. I understand that any discharge of wastewater from this non - discharge system to surface waters or the land will result in an immediate enforcement action that may include civil penalties, injunctive relief, and/or criminal prosecution. 1 will make no claim against the Division of Water Resources should a condition of this permit be violated. I also understand that if all required parts of this application package are not completed and that if all required supporting information and attachments are not included, this application package will be returned to me as incomplete. NOTE In accordance with General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed SI0,000 as well as civil penalties up to S25,000 per violation. Signature: C . Date: FORM: FTA 04-16 Page 5 of 5 MORRIS & RITCHIE ASSOCIATES OF NC, PC AN AFFILIATE OF MORRIS & RITCHIE ASSOCIATES, INC. WHICH PROVIDES ENGINEERING, ARCHITECTURE, PLANNING, SURVEYING & LANDSCAPE ARCHITECTURE THROUGHOUT THE MID -ATLANTIC REGION August 2, 2018 Raleigh Regional Office Water Quality Section 1628 Mail Service Center Raleigh, NC 27699-1628 Re: Fast Track Sewer Extension Application McGee's Crossroads Sewer Upgrade Phase 2B (CS370560-16) Johnston County, North Carolina Dear Sir or Madam: NC Dept "Environmental QI,LjijIv AUG 14 2018 Raleigh Regional Office Please find enclosed the Fast Track Sewer System Application, Flow Tacking/Acceptance for Sewer Extension Applications, and Location Map for the above referenced project. The proposed project consists of the construction of 8,239 LF of 27" gravity sewer line that will connect to the proposed Middle Creek Regional Pump Station (permitted as a separate project). Johnston County has experienced dramatic increase in residential and commercial growth especially in areas within the County's sewer service area. Current flow within the existing force main serving the McGee's Crossroads sewer area is close to exceeding the maximum allowable pressure. This project is required to provide additional capacity, relieve the flow on an existing force main, and construct a regional pump station (as a separate project) to meet current and future sewer demands. The above reference phase proposes a gravity sewer main parallel to Middle Creek to the proposed regional pump station. Construction of this sewer main will replace two pump stations and ultimately a third pump station at full build -out Since this a new sewer main, there will be no existing flow that will require bypass during the construction of the project. The future projected in the gravity sewer line is estimated as follows: Future ADF w/o equalization: 1,175 GPM Peak Hour: 2,937.5 GPM Future ADF w/ equalization: 1,304 GPM Peak Hour: 3,260 GPM Please let me know if you need additional information. AThyou ameGuerrero Associate Enclosures: Fast Track Sewer System Application Flow Tracking/Acceptance for Sewer Extension Applications Aerial Location Map Application Fee of $480.00 payable to NCDEQ 5605 Chapel Hill Road, Suite 112, Raleigh, NC 27607 (984) 200-2103 www.mragta.com Abingdon, MD 4 Bakimore, MD ♦ Laurel, MD i Towson, MD ♦ Georgetown, DE ♦ New Castle, DE t Steding, VA ♦ Raleigh, NC (410) 515-9000 (410) 935-5050 (410) 792-9792 (410) 821-7 690 (302) 855-5734 (302) 326-2200 (703) 674.0161 (984) 200-2103 State of North Carolina Department of Environment and Natural Resources DWR Division of Water Resources Division of Water Resources Flow Tracking/Acceptance for Sewer Extension Applications (FTSE 08-13) Project Applicant Name: Johnston County Project Name for which flow is being requested: McGee's Sewer Upgrade Phase 2 More than one FTSE may be required for a single project if the owner of the WWTP is not responsible for all pump stations along the route of the proposed wastewaterflow. I. Complete this section only if you are the owner of the wastewater treatment plant. a. WWTP Facility Name: Central Johnston County WWTP b. WWTP Facility Permit #: NC0030716 All flows are in MGD c. WWTP facility's permitted flow 9.5 MGD C- d. Estimated obligated flow not yet tributary to the WWTP 1.8728 e. WWTP facility's actual avg. flow 5.4020 N f Total flow for this specific request _0.0 0 �,- g. Total actual and obligated flows to the facility 7.3011 h. Percent of permitted flow used 76.9% Q II. Complete this section for each pump station you are responsible for along the route of fis proposed wastewater flow. Z List pump stations located between the project connection point and the WWTP: (A) (B) (C) (D)=(B+C) (E)=(A-D) Design Obligated, Pump Average Daily Approx. Not Yet Total Current Station Firm Flow** Current Avg. Tributary Flow Plus (Name or Capacity,* (Firm ' p0, Daily Flow, Daily Flow, Obligated Available Number) MGD MGD MGD MGD Flow Capacity*** New Middle Creek 1.44 0.576 0 0 0 0.576 Landfill EQ 1.9296 1.67184 0.67180 0.39265 1.06445 0.6074 * The Firm Capacity of any pump station is defined as the maximum pumped flow that can be achieved with the largest pump taken out of service. ** Design Average Daily Flow is the firm capacity of the pump station divided by a peaking factor (po not less than 2.5. *** A Planning Assessment Addendum shall be attached for each pump station located between the project connection point and the WWTP where the Available Capacity is ¢ 0. NS e Page l of 6 FTSE 08-13 I1I. Certification Statement: I Chandra C. Coats, P.E. certify to the best of my knowledge that the addition of the volume of wastewater to be permitted in this project has been evaluated along the route to the receiving wastewater treatment facility and that the flow from this project is not anticipated to cause any -capacity -related sanitary -sewer -overflows or -overburden any -downstream -pump station en route to the receiving treatment plant under normal circumstances, given the implementation of the planned improvements identified in the planning assessment where applicable. This analysis has been performed in accordance with local established policies and procedures using the best available data. This certification applies to those items listed above in Sections I and II plus all attached planning assessment addendums for which I am the responsible party. Signature of this form indicates acceptance of this wastewater flow. Signing Official Signature Page 2 of 6 I+TSE 08-13