Loading...
HomeMy WebLinkAboutNCG550215_Compliance Evaluation Inspection_20181008 ROY COOPER NORTH CAROLINA Governor Environmental Quality MICHAEL S.REGAN Secretary LINDA CULPEPPER RECE\ IDE RI\D" Interim Director ©C 1 l q �nqp October 8, 2018 1,1 U I(! water R 9 Section Reymundo Ramos permitting 6709 Whitney Road Graham,NC 27253 SUBJECT: Compliance Evaluation Inspection Report . Certificate of Coverage NCG550215 under NPDES General Permit NCG550000 Facility Located at 6709 Whitney Road,Alamance County Dear Mr. Ramos: On September 19, 2018, Paul DiMatteo of this office met with you to perform a Compliance Evaluation Inspection on the subject wastewater treatment facility. The Division is required to inspect these types of systems at least every 5 years. An inspection summary follows. Site Review The system consists of a septic tank, subsurface sand filter,and outfall with final disposal to Marys Creek, class WS-V, NSW waters in the Cape Fear River Basin. No sewage malfunction was observed at or around the septic tank. There was no discharge at the outfall. According to our records, there is no chlorination unit on this system due to its age. Documentation & Monitoring Review A review of documentation was not conducted at the time of inspection. We would like to remind you to conduct and document the following: - Effluent monitoring must be performed as required in the permit. - All system components must be maintained at all times and in good working order. - Inspect the septic tank and secondary tanks at least yearly to determine if solids must be removed. - Pump the septic tank every 5 years, or when the solids level is found to be more than 1/3 of the liquid depth in any compartment, whichever is greater. All tanks should be emptied of their contents whenever any of the tanks meet this requirement. - Contents removed from septic tanks shall be disposed of at a location and in a manner compliant with all local and state regulations. - Inspect the outfall location at least twice per year to ensure that no visible solids or other obvious evidence of system malfunctioning is observed. , ,-1:1111EQ„) NORTH CAROLINA ��` DRmRmem m Emrtmmnnnr 0�Y North Carolina Department of Environmental Quality I Division of Water Resources Winston-Salem Regional Office 1450 Hanes Mill Road,Suite 300 I Winston-Salem,North Carolina 27103 336.776.9800 NCG550215, 6709 Whitney Road September 19, 2018 - Inspect the tablet chlorinator (if applicable) at least weekly to ensure there is an adequate supply of tablets for continuous&proper operation.Tablets used for chlorination must be labeled for wastewater use. - Any monitoring data obtained shall be retained onsite for a minimum of 5 years. - Additional requirements as stated in NCG550000. Finally, our database indicates that you have overdue invoices for your permit annual fee. A copy of this invoice with payment instructions is enclosed. Please be aware that violations of your NPDES Certificate of Coverage, or the NC statutes and regulations under which it is promulgated, are subject to fines of up to $25,000 per day, per violation, as set forth in NC General Statute 143-215.6A, Enforcement Procedures, Civil Penalties. If you should have any questions,please do not hesitate to contact Paul DiMatteo at 336-776-9691 or our office at 336-776-9800. Sincerely, Sherri V. Knight, P.E. Regional Supervisor Water Quality Regional Operations Division of Water Resources Attachments: (1)EPA Water Compliance Inspection Report, (2) Invoice 2016PR007987 cc: WSRO NPDES Unit Page 2 of 2 it United States Environmental Protection Agency Form Approved. EPA Washington,D.0 20460 OMB No 2040-0057 Water Compliance Inspection Report Approval expires 8-31-98 Section A.National Data System Coding(i.e,PCS) Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type 1 1 2 15 I 3 I NCG550215 111 12 I 18/09/19 117 18I(.I 19 G 201 I 21111111111111111111111111111111111111111111P6 Inspection Work Days Facility Self-Monitoring Evaluation Rating B1 QA — --Reserved- 671 1 70 I 1 71 1 I 72 I—I N I 731 I 174 751 I I 1 1 1 1 180 Section B-Facility Data 1 Name and Location of Facility Inspected(For Industrial Users discharging to POTW,also include Entry Time/Date Permit Effective Date POTW name and NPDES'permit Number) 02 30PM 18/09/19 13/08/01 6709 Whitney Road Exit Time/Date Permit Expiration Date 6709 Whitey Rd 03 15PM 18/09/19 18/07/31 Graham NC 27253 Name(s)of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) Other Facility Data /// Name,Address of Responsible Official/Title/Phone and Fax Number Contacted Reymundo Ramos,6709 Whitney Rd Graham NC 2725311321-331-9096/ No Section C Areas Evaluated During Inspection(Check only those areas evaluated) Permit • Facility Site Review El Effluent/Receiving Waters Section D Summary of Finding/Comments(Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s)and Signature(s)of Inspector(s) Agency/Office/Phone and Fax Numbers Date Paul DiMatteo WSRO WQ//336-776-9691/ ?,0_,Q 11)40;3 Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date EPA Form 3560-3(Rev 9-94)Previous editions are obsolete Page# 1 Permit: NCG550215 Owner-Facility: 6709 Whitney Road Inspection Date: 09/19/2018 Inspection Type: Compliance Evaluation Permit Yes No NA NE (If the present permit expires in 6 months or less). Has the permittee submitted a new ❑ ❑ M ❑ application? Is the facility as described in the permit? • 01=11=1 #Are there any special conditions for the permit? ❑ • ❑ ❑ Is access to the plant site restricted to the general public? MOOD Is the inspector granted access to all areas for•inspection? MOOD Comment: Effluent Pipe • Yes No NA NE Is right of way to the outfall properly maintained? ❑ ❑ • ❑ Are the receiving water free of foam other than trace amounts and other debris'? ODOM If effluent (diffuser pipes are required) are they operating properly'? ❑ ❑ ❑ • Comment: The outfall was located at 35.919333 N, 79.310611 W. There was no discharge at the time of inspection. Page# 3