HomeMy WebLinkAboutNCG550402_Compliance Evaluation Inspection_20181008 far r\ ROY COOPER NORTH CAROLINA Governor Environmental Quality MICHAEL S.REGAN Secretary LINDA CULPEPPER Interim Director October 8, 2018 Ms. Darlene Deyton 158 Deep Gap Estates Rd. Deep Gap, NC 28618 RECEO�ED/DEi2018��®W� SUBJECT: Compliance Evaluation Inspection Certificate of Coverage: NCG550402 \NeterOCT Resources 17 158 Deep Gap Estates Rd, Deep Gap Permitting Section Ashe County Dear Ms. Deyton, On October 3, 2018 Kelli Park, of this office, conducted a compliance evaluation inspection of the wastewater treatment system located at the above address. The State requires the Division of Water Resources to inspect these types of systems every five years. Miss Park was unable to locate the effluent discharge pipe, however there was no odor and there were no noticeable impacts to the stream. It is a permit requirement to have the area around the effluent pipe cleared and maintained. Effluent being discharged in the stream should also be checked periodically to ensure that no solids are being discharged and that there are no impacts to the stream. Via a phone conversation with Miss Park you reported that you are not sure where the effluent pipe is. Please investigate this matter and determine where the outflow is, as it is critical to check the effluent and a permit requirement to maintain the area to and around the outfall. Chlorine is not required in your system since it was installed in 1986. The permit also requires that the septic tank contents be pumped out every 3-5 years to prevent solids from clogging the sand filter system. Via a phone conversation with Miss Park the system was pumped last in 2012. The system is overdue to be pumped. Please get the system pumped again immediately, let Miss Park know that it was pumped, and keep records of septic tank pumping on hand as a historical record and proof that you had the tank pumped. Since you have been unable to locate the effluent pipe, discharge samples have not been analyzed. Water samples from the effluent are required to be analyzed at least once a NORTH CAROuN OepmCnenl of Environmental Cuallryy North Carolina Department of Environmental Quality I Division of Water Resources Winston-Salem Regional Office 1450 Hanes Mill Road,Suite 300 I Winston-Salem,North Carolina 27103 336.776.9800 , United States Environmental Protection Agency Form Approved. EPA Washington,D C 20460 OMB No 2040-0057 Water Compliance Inspection Report Approval expires 8-31-98 Section A.National Data System Coding(i.e,PCS) Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type 1 E 2 IL I 3 NCG550402 111 12(1 18/10/03 117 18 (11, 191 c I 2011 21111111 1111111111111111111111111 11111111111 p6 Inspection Work Days Facility Self-Monitoring Evaluation Rating B1 QA -Reserved- 67I I 70 I I 71 1 I 72 I N IL—I 731 1 1' 751 I I I 1 1 1 180 Section B Facility Data J Name and Location of Facility Inspected(For Industrial Users discharging to POTW,also include Entry Time/Date Permit Effective Date POTW name and NPDES permit Number) 02 20PM 18/10/03 13/08/01 158 Deep Gap Estates Road Exit Time/Date Permit Expiration Date 158 Deep Gap Estates Rd 02 45PM 18/10/03 18/07/31 Deep Gap NC 28618 Name(s)of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) Other Facility Data /1/ Name,Address of Responsible Official/Title/Phone and Fax Number Contacted Darlene Deyton,PO Box 152 Deep Gap NC 28618/1336-877-3178/ No Section C Areas Evaluated During Inspection(Check only those areas evaluated) Permit • Facility Site Review • Effluent/Receiving Waters Section D Summary of Finding/Comments(Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s)and Signature(s)of Inspector(s) Agency/Office/Phone and Fax Numbers Date Kelli A Park WSRO WQ//336-776-9689/ 4/vik./6071._ Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date EPA Form 3560-3(Rev 9-94)Previous editions are obsolete Page# 1 v t Permit: NCG550402 Owner-Facility: 158 Deep Gap Estates Road Inspection Date: 10/03/2018 Inspection Type: Compliance Evaluation Permit Yes No NA NE (If the present permit expires in 6 months or less). Has the permittee submitted a new 0 ❑ • ❑ application? Is the facility as described in the permit? MI ❑ ❑ El #Are there any special conditions for the permit? ❑ • ❑ El Is access to the plant site restricted to the general public'? 0 U ❑ 0 Is the inspector granted access to all areas for inspection? In ❑ ❑ ❑ Comment. SFR Effluent Pipei Yes No NA NE Is right of way to the outfall properly maintained? ❑ • El 0 Are the receiving water free of foam other than trace amounts and other debris'? U ❑ El ❑ If effluent (diffuser pipes are required) are they operating properly'? ❑ ❑ U 0 Comment' The effluent pipe was not located and Mrs. Dayton is unaware of where the pipe is.Via the inspection letter I have asked her to find the pipe and maintain the right of way. Page# 3