Loading...
HomeMy WebLinkAboutNC0029980_Compliance Evaluation Inspection_20180730 I' , Tr • y ROY COOPER NORTH CAROLINA Governor Environmental Quality MICHAEL S.REGAN Secretary LINDA CULPEPPER �9 �e `l p' ��! Interim Director ��4J�0 V E®'®�Itl ®�v July 30, 2018 AUG 0 �' 201 Andrew C. Lucas V1Pater Respect on MillerCoors LLC �erm►tting 863 E. Meadow Road Eden, NC 27288-3636 Subject: Compliance Evaluation Inspection Report NPDES Permit#NC0029980 MillerCoors LLC WWTP, Rockingham County Dear Mr. Lucas: On July 10, 2018, Paul DiMatteo and Rebecca Chandler of the Division of Water Resources(Division), Winston- Salem Regional Office, conducted a Compliance Evaluation Inspection of the above referenced wastewater treatment system.You were present for the inspection. During the inspection you gave a tour of the facility and explained future plans.The inspection is summarized below and a report is attached for your records. Site Review 1. Permit The current permit became effective on June 1, 2012 and expired on April 30, 2017.A renewal application was submitted in October of 2016. Permitted components influent screw lift pumps, manual bar screen,grit chamber, aeration basins,secondary clarifiers, and polishing lagoons. 2. Facility Site Review The facility was as described in the permit.The facility ceased operation in September 2016 and no wastewater has flowed to the plant since March 2017.The plant was reportedly drained and cleaned before ceasing discharge.Some mechanical equipment appeared to have surface rust and you noted that the rubber diffuser membranes in the aeration basins had been exposed to the sun since 2017 and would likely need to be replaced to function properly. It was also noted that several of the aeration basins have not retained water introduced during rain events and are likely leaking.There did not appear to be any evidence of wastewater entering the facility since it ceased operation. Please be advised that this office has recommended to the permit writers that WSRO approval be required before restarting the facility, in order to verify that maintenance issues have been corrected. NORTH �� Q� ROPMeta 01EARRNmeM11(Nat\jel...° North Carolina Department of Environmental Quality I Division of Water Resources Winston-Salem Regional Office 1450 Hanes Mill Road,Suite 300 I Winston-Salem,North Carolina 27103 336.776.9800 I If you should have any questions, please do not hesitate to contact Paul DiMatteo at(336) 776-9691 or our office at(336)776-9800. Sincerely, / —jam _/q,4 ' Sherri V. Knight, P.E., Regional Supervisor Water Quality Regional Operations Section ' Winston-Salem Regional Office Division of Water Resources, NCDEQ Enclosures—Inspection Report and Summary CC: WQS Winston-Salem Regional Office ' NPDES Compliance/Enforcement Unit Central Files 1 c°1 D E illri)=.:4 m�fimimenmiaoume /od North Carolina Department of Environmental Quality I Division of Water Resources Winston-Salem Regional Office 1450 Hanes Mill Road,Suite 300 I Winston-Salem,North Carolina 27103 336.776.9800 i • United States Environmental Protection Agency EPA Form Approved Washington,D C 20460 OMB No.2040-0057 Water Compliance Inspection Report Approval expires 8-31-98 Section A National Data System Coding(i.e.,PCS) Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type 1 N I 2 [ I 3 I NC0029980 111 12 I 18/07/10 ' 117 18 1,.1 19 I s I 201 1 2111111111111111111111111111IIItI IIIIII111II 166 Inspection Work Days Facility Self-Monitoring Evaluation Rating B1 QA Reserved— k 671 I 70I I 71 1 I 72 LI] 731 1 174 751 1 1 1 1 1 1 180 Section B Facility Data Name and Location of Facility Inspected(For Industrial Users discharging to POTW,also include Entry Time/Date Permit Effective Date POTW name and NPDES permit Number) 10 15AM 18/07/10 12/06/01 MillerCoors LLC 863 E Meadow Rd a Exit Time/Date Permit Expiration Date Eden NC 272883636 12-00PM 18/07/10 17/04/30 Name(s)of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) Other Facility Data /// Andrew C Lucas/ORC/336-613-1665/ Name,Address of Responsible Official/Title/Phone and Fax Number Contacted Andrew C Lucas,863 E Meadow Rd Eden NC 272883636/Site Representative/336-613-1665/ No Section C Areas Evaluated During Inspection(Check only those areas evaluated) • Permit • Operations&Maintenance • Facility Site Review Section D Summary of Finding/Comments(Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s)and Signature(s)of Inspector(s) Agency/Office/Phone and Fax Numbers Date Paul DiMatteo WSRO WQ//336-776-9691/ Rebe a D Chandler WSRO WQ//336-776-9692/ 71640,d' pa_e Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date .><V 7/ // $ EPA Form 3560-3(Rev 9-94)Previous editions are obsolete Page# 1 NPDES yr/mo/day Inspection Type (Cont.) 1 3IL NC0029980 Il 1 121 18/07/10 11 7 18 Li Section D•Summary of Finding/Comments(Attach additional sheets of narrative and checklists as necessary) The plant ceased operation in September 2016 and no wastewater has flowed to the plant since around March 2017. The plant was reportedly drained and cleaned before ceasing discharge. Some mechanical equipment appeared to have surface rust and Mr. Lucas noted that the rubber diffuser membranes in the aeration basins had been exposed to the sun since 2017 and would likely need replacing to function properly. Mr. Lucas also noted that the SCADA system that was in use was proprietary and the operational hardware had been removed from the facility. Page# 2 Permit: NC0029980 Owner-Facility: MillerCoors LLC Inspection Date: 07/10/2018 Inspection Type: Compliance Evaluation Operations & Maintenance Yes No NA NE Is the plant generally clean with acceptable housekeeping? • 0 0 0 Does the facility analyze process control parameters,for ex: MLSS, MCRT,Settleable 0 0 • 0 Solids, pH, DO, Sludge Judge,and other that are applicable? Comment: Permit Yes No NA NE (If the present permit expires in 6 months or less). Has the permittee submitted a new ❑ 0 • 0 application? Is'the facility as described in the permit? • ❑ 0 0 #Are there any special conditions for the permit? - 0 • 0 0 Is access to the plant site restricted to the general public? • ❑ 0 ❑ Is the inspector granted access to all areas for inspection? • 0 0 0 Comment: A renewal application was submitted in 2016 and is currently under review. Mr. Lucas explained that they wished do keep the permit active for a potential sale. Pump Station - Influent Yes No NA NE Is the pump wet well free of bypass lines or structures? • 0 ❑ 0 Is the wet well free of excessive grease? 0 0 II 0 Are all pumps present? • 0 0 ❑ Are all pumps operable? 0 0 0 U Are float controls operable? ❑ 0 0 • Is SCADA telemetry available and operational? 0 0 0 II Is audible and visual alarm available and operational? ❑ ❑ 0 U Comment: Page# 3