Loading...
HomeMy WebLinkAboutNC0086959_Compliance Evaluation Inspection_20181029 .6.04,,..".0 ' .11.4 , ;•.; �4' T 40, er. :"ms's ••'N. __ ^-t'"'' - — - ____ ri,3•i.'ten',. - q + August 29, 2018 Joseph H Threewitts Northwestern / Belfast-Patetown Sanitary District PO Box 1583 Goldsboro, NC 27533-1583 SUBJECT: Compliance Inspection Report Memorial Church Road WTP #2 - NPDES WW Permit No. NC0086959 Wayne County Dear Mr. Threewitts: The North Carolina Division of Water Resources conducted an-inspection of the Memorial Church Road , WTP #2 on 8/28/2018. This inspection was conducted to verify that the facility is operating in compliance with the conditions and limitations specified in NPDES WW Permit No. NC0086959. The findings and comments noted during this inspection are provided in the enclosed copy of the inspection report entitled "Compliance Inspection Report". Thank you Mr. Threewitts for your time and tour of the facility. There were no significant issues or findings noted during the inspection and therefore, a response to this inspection report is not required. If you should have any questions, please do not hesitate to contact Stewart White with the Water Quality Regional Operations Section in the Washington Regional Office at 252-946-6481 or via email at stewart.white@ncdenr.gov. — -- Sincerely, ` -- rj Stewart White, Environmental Specialist I Water Quality Regional Operations Section Washington Regional Office North Carolina Department of Environmental Quality I Division of Water Resources 943 Washington Square Mall,Washington,NC 27889 252-946-6481 Division of Water Resources, NCDEQ ATTACHMENTS Cc: WQS Washington Regional Office NPDES Compliance/Enforcement Unit • - r4yE F-�_ - "_-��±a"" .14 North Carolina Department of Environmental Quality I Division of Water Resources 943 Washington Square Mall,Washington,NC 27889 252-946-6481 United States Environmental Protection Agency Form Approved EPA Washington,D C 20460 OMB No 2040-0057 Water Compliance Inspection Report Approval expires 8-31-98 Section A National Data System Coding(i e,PCS) Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type 1 LI 2 EI 3 NC0086959 111 12 1 18/08/28 117 18i 19 Li i 201 21111111 1111111111111111111111111 11111111111 166 Inspection Work Days Facility Self-Monitonng Evaluation Rating B1 QA Reserved 671 1 70l�1, I 71 L- 1 I 72 1 �, 1 1 731 I V 75I -1 1 1 1 1 1 180 Section B•Facility Data J Name and Location of Facility Inspected(For Industrial Users discharging to POTW,also include Entry Time/Date Permit Effective Date POTW name and NPDES permit Number) 09 55AM 18/08/28 14/03/01 Memonal Church Road WTP#2 NCSR 1342 NC Hwy 581 Exit Time/Date Permit Expiration Date 11 15AM 18/08/28 18/05/31 Goldsboro NC 27533 Name(s)of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) Other Facility Data /// Joseph H Threewitts/ORC/919-731-2310/ Name,Address of Responsible Official/Title/Phone and Fax Number Contacted Joseph H Threewits,P0 Box 1583 Goldsboro NC 275331583//919-731-2310/9197315994 No Section C:Areas Evaluated During Inspection(Check only those areas evaluated) Permit • Operations&Maintenance • Records/Reports IN Facility Site Review Section D:Summary of Finding/Comments(Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s)and Signature(s)of Inspector(s) Agency/Office/Phone and Fax Numbers Date _Stewart_White___ _VNARO_WQ//252.948 3940 _ Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date EPA Form 3560-3(Rev 9-94)Previous editions are obsolete Page# 1 e NPDES yr/mo/day Inspection Type (Cont.) 1 31 N00086959 111 121 18/08/28 1 17 18 I c I Section D.Summary of Finding/Comments(Attach additional sheets of narrative and checklists as necessary) Permit#NC0086959 Memorial Church Road WTP has radioactive waste Radium 226&228 Analytical Results were viewed by Stewart White during inspection.Also Radiation Safety Officer William Deforest visited site to inspect waste before shipping out of Goldsboro by train-12/5/2017 to Idaho. ORC Joseph Threewitts stated in e-mail they shipped 218,000 lbs.The cost between $150,000- $200,000 to dispose waste.The Facility was clean and well maintained. Radioactive Signs were posted at facility and fence was in very good condition. Lab was Decertified 2007. 2017 annual discharge 90,500 gallons. June 2018 Discharged 38,000 gallons Page# 2 Permit NC0086959' _ Owner-Facility: Memonal Church Road WTP#2 Inspection Date: 08/28/2018 Inspection Type: Compliance Evaluation Permit Yes No NA NE (If the present permit expires in 6 months or less) Has the permittee submitted a new • El 0 0 application'? Is the facility as described in the permit'? • 0 0 0 #Are there any special conditions for the permit? 0 0 I El Is access to the plant site restricted to the general public? • 0 0 0 Is the inspector granted access to all areas for inspection? • 0 0 0 Comment: Permit Expiration 5/31/2023 Record Keeping Yes No NA NE Are records kept and maintained as required by the permit'? • 0 0 ❑ Is all required information readily available, complete and current'? • El 0 0 Are all records maintained for 3 years(lab reg required 5 years)? • 0 0 0 Are analytical results consistent with data reported on DMRs? U ❑ El El Is the chain-of-custody complete'? • 0 El ❑ Dates,times and location of sampling 0 Name of individual performing the sampling 0 Results of analysis and calibration 0 Dates of analysis 0 Name of person performing analyses 0 Transported COCs 0 Are DMRs complete:do they include all permit parameters'? U El 0 El Has the facility submitted its annual compliance report to users and DWQ? ❑ El El U (If the facility is=or>5 MGD permitted flow)Do they operate 24/7 with a certified operator • El ❑ El on each shift'? Is the ORC visitation log available and current'? • El ❑• El Is the ORC certified at grade equal to or higher than the facility classification'? • ❑ ❑ El Is the backup operator certified at one grade less or greater than the facility classification'? • ❑ El ❑ Is a copy of the current NPDES permit available on site'? • ❑ El ❑ Facility has copy of previous year's Annual Report on file for review'? 0 El ❑ • Comment Wayne County Water District has five operators. (Approximately 26 Employees total)The ORC Joseph Threewitts records were availible well organized.Reviewed 2017 and January -July 2018 Facility discharged August 2017 and June 2018. June 21,2018 Manganse 134 ug/I and Iron 2065 ug/I Page# 3 Permit NC0086959 Owner-Facility: Memorial Church Road WTP#2 Inspection Date: 08/28/2018 Inspection Type: Compliance Evaluation Operations &Maintenance Yes No NA NE Is the plant generally clean with acceptable housekeeping? • ❑ 0 0 Does the facility analyze process control parameters,for ex MLSS, MCRT,Settleable , 0 0 N 0 Solids,pH, DO,Sludge Judge,and other that are applicable'? Comment: 8/8/17 pH 6.9 TSS 3.3 mg/I 8/9/17 pH 6 82 TSS 6.5 mg/I Page# 4