Loading...
HomeMy WebLinkAboutWQ0037792_More Information Requested_20150821AVkXWA NCDENR North Carolina Department of Environment and Natural Resources Pat McCrory Governor Erik Lensch 108 Standing Rock Road Chapel Hill, North Carolina 27516 Dear Mr. Lensch: Division of Water received .May 13, 2015. completed. Please addre, September 25, 2015. Donald R. van der Vaart Secretary August 21, 2015 Subject: Application No. WQ0037792 Additional Information Request Lot #5 Pickard Meadows Road SFR Single Family Residence Wastewater Irrigation System Orange County Resources' Central and Regional staff has reviewed the application package However, additional information is required before the review may be s the items on the attached pages no later than the close of business on Please be aware that you are responsible for meeting all requirements set forth in North Carolina rules and regulations. Any oversights that occurred in the review of the subject application package are still the Applicant's responsibility. In addition, any omissions made in responding to the outstanding items A through H or failure to provide the additional information on or before the above requested date may result in your application being returned as incomplete. Please reference the subject application number when providing the requested information. All revised and/or additional documentation shall be signed, sealed and dated (where needed), with three copies submitted to my attention at the address below. If you have any questions regarding this request, please do not hesitate to contact me at (919) 807-6425 or alice.wessner@ncdenr.gov. Thank you for your cooperation. Sincerely, Alice M. Wessner, Environmental Engineer Division of Water Resources cc: Raleigh Regional Office, Water Quality Regional Operations Section (Electronic Copy) Kevin D. Davidson, P.E., Agri -Waste Technology, Inc. (Electronic Copy) Permit Application File WQ0037792 1636 Mail Service Center, Raleigh, North Carolina 27699-1636 Phone: 91M07-64641Internet: htto:llnortalmdenr.or Iwq e��u An Equal Opportunity 1 Affirmative Action Employer — Made in part with recycled paper Mr. Lensch August 21, 2015 Page 2 of 3 A. Application: Item V11.4. There are inconsistencies between the application, engineering plans and the SFR Loading Rate worksheet. a. The application indicates there is a 0.53 acre field. b. The SFR Loading Rate worksheet indicates a 0.33 acre field. c. The engineering plans show a wetted area roughly 17,000 square feet or 0.39 acres. Please revise so that the information is consistent throughout the application and recalculate where necessary. B. Plat Map: 1. During the site inspection, potential wetland features were identified that were not indicated on the plans. These features must be delineated and surveyed as well as the surface water features buffered with a setback distance of 100 feet. Please provide an updated site map with wetland features (adjacent to the eastern border) delineated. Please revise the drip field layout accordingly. 2. Potential wetland features were identified during the site inspection that was not indicated on the plans. These features must be delineated and surveyed in addition to the surface water features being buffered with a setback distance of 100 feet. PIease provide an updated site neap with wetland features (adjacent to the eastern border) delineated. Please revise the drip field layout accordingly C. Plans: 1. The design drawings indicate a stream with a sinuosity and meander belt width lower that what was observed during the site inspection. The existing stream channel appears to be within the setback to surface waters of 100 feet. Please survey the top of the stream bank and revise the drip field layout as necessary by providing an updated site map showing the tributary adjacent to the southern border as it exists in the field. 2. Please add the design wetted area in square feet to the drip field layout sheet WW-4 as well as line average spacing distances. Also, include this information on the drip field detail sheet WW- 8. D. Enzineerin�Calculations: 1. Please provide biological treatment process calculations to support the effluent design quality or submit effluent data from existing AX25 systems in North Carolina that can demonstrate the proposed system can meet the minimum level of treatment for systems treating 600 gallons per day or greater. E. Operation & Maintenance Plan: 1. Please amend the drip field maintenance section in the O&M Plan to provide recommendations for turf maintenance which includes occasional cutting with the method of cutting, regular time Mr. Lensch August 21, 2015 Page 3 of 3 application, and any other recommendations to facilitate the inspection of the drip line for integrity and leaks and to support the fescue as a cover crop. Please note that a final O&M Plan may be submitted with the Engineering Certification, however, a preliminary O&M Plan shall be submitted with the application package. 1;: Threatened or Endangered Aquatic Species Documentation: 1. No Threatened or Endangered Aquatic Species documentation was submitted with this application package. This documentation is required for all application packages per 15A NCAC 02T .0105(c)(10). Please submit documentation from the Department's Natural Heritage Program demonstrating the presence or absence of threatened or endangered aquatic species within the boundary of the wastewater treatment, storage and irrigation facilities. If the facility directly impacts such species, this documentation shall provide information on the need for permit conditions in the new permit. The map submitted is incomplete.