September 27, 2018 RECEIVEo/DENR/owR
Dennis K Thomas OCT 0 2 2018
City of Burlington Water Resources
PO Box 1358 Permitting Section
Green Level, NC 27217
SUBJECT: Compliance Evaluation Inspection Report
J.D. Mackintosh WTP
Certificate of Coverage NCG590013 under NPDES General Permit NCG590000
Alamance County
Dear Mr. Thomas:
On September 6, 2018, Paul DiMatteo of this office met with you, operator in responsible charge
(ORC), to perform a Compliance Evaluation Inspection on the subject wastewater treatment facility. This
type of inspection consists of two basic parts: an in-office file review and an on-site inspection of the
treatment facility. The attached inspection form notes the areas that were evaluated for this inspection. The
findings and observations are outlined as follows. -
I. Permit
The general permit became effective on August 1, 2014 and will expire on July 31, 2019. A copy of
the current permit was available during the inspection. The facility was as described in the permit.
II. Self-Monitoring Program
A review of discharge monitoring reports (DMRs) from December 2016 through July 2018 revealed
no actioned violations. Sampling is being conducted at the location and frequency specified by the permit.
One composite whole effluent toxicity sample is required annually. Mr. Thomas said the sample is collected
by hand, by filling a 250-milliliter (ml) sample jug every hour during a time that the effluent pumps are run
continuously and combining the aliquots./The flow for the day should be reviewed and aliquot volumes
adjusted to ensure the sample is proportional to the flow, with no aliquot being less than 100 ml. Mr. Thomas
said he may set up a continuous drip line to take the sample. In this case, care should be taken to ensure
the sample is properly preserved during collection (e.g. by refrigeration).
The facility measures residual chlorine, pH and temperature at the on-site laboratory under the City
of Burlington's WWTP lab certification,#188. Other analyses are performed by Burlington's main laboratory.
Field parameter calibration records and procedures appeared acceptable, save for the digital thermometer
used to measure effluent temperature, which should be checked against an NIST-traceable thermometer
Qif)NORTH CAROLJNA
UpCNmm of 9nhwmenW 0�
North Carolina Department of Environmental Quality I Division of Water Resources
Winston-Salem Regional Office 1450 Hanes Mill Road,Suite 300 I Winston-Salem,North Carolina 27103
336.776.9800
V; J.D. Mackintosh WTP, 9/6/2018
yearly. Note, however, that the General Permit does not require effluent temperature measurement, but
such measurements must be reported if conducted.
Ill. Records/Reports
Copies of DMRs, operator visitation logs, daily operation sheets, maintenance reports, lab reports
and chain-of-custody forms were available for review during the inspection. DMRs and lab data are
maintained according to the permit. DMRs include all permit parameters. A comparison of submitted data
with available field lab bench sheets revealed no errors or concerns. Non-field bench sheets are maintained
at Burlington's main laboratory and were not evaluated during the inspection.
IV. Flow Measurement
Effluent flow is measured using a Venturi meter set in the effluent pump force main and recorded
using SCADA. The meter is calibrated quarterly by Instrument Services, Inc. The last calibration was
conducted in June, 2018.
V. Operations and Maintenance
The plant is operated as required. All operators are properly designated and hold adequate
certifications. The facility appeared to be well operated and managed.
VI. Facility Site Review
The plant has two settling lagoons that are used interchangeably to manage filter backwash. Lagoon
#1 was down for sludge clearing, which is handled by EMA Resources. No problems were noted during the
inspection.
VII. Effluent/Receivinq Waters
Treated effluent is discharged to Big Alamance Creek just below the Lake Mackintosh dam, class
WS-V; NSW waters in the Cape Fear River Basin. Effluent appeared clear with no visible impact to the
receiving stream.
The compliance evaluation inspection is satisfactory. If you have any questions regarding the
inspection or this report, please contact Paul DiMatteo at (336) 776-9691 or me at (336) 776-9800.
Sincerely,
!/ 8
J +..Zi,t, V. ,mow t,5&)
Sherri V. Knight, P.E.
Regional Supervisor
Water Quality Regional Operations
Division of Water Resources
Attachments: BIMS EPA Water Compliance Inspection Report
cc: WSRO
NPDES Unit
Central Files
Page 2 of 2
I•
United States Environmental Protection Agency
Form Approved
EPA Washington,D C 20460 OMB No 2040-0057
Water Compliance Inspection Report Approval expires 8-31-98
Section A:National Data System Coding(i.e.,PCS)
Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type
1 IN I 2 IL I 3 I NCG590013 111 12 I 18/09/06 117 18 11_1°I 19 I S I 201
21111111 1111111111111111111111111 11111111111 p6
Inspection Work Days Facility Self-Monitoring Evaluation Rating B1 QA Reserved —
671 1 7° 1 I 71 Ii 72 1 I 731 I FYI 1 1 1 1 1 1 180
Section B:Facility Data l
Name and Location of Facility Inspected(For Industrial Users discharging to POTW,also include Entry Time/Date Permit Effective Date
POTW name and NPDES permit Number) 09 30AM 18/09/06 16/12/01
J D Mackintosh,Jr WTP
Exit Time/Date Permit Expiration Date
3400 Harris Rd
Burlington NC 27215 10 30AM 18/09/06 19/07/31
Name(s)of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) Other Facility Data
///
Dennis K Thomas/ORC/336-222-5132/
Name,Address of Responsible Official/Title/Phone and Fax Number
Contacted
Dennis K Thomas,Po 1358 Green Level NC 27217//336-584-1394/
No
Section C.Areas Evaluated During Inspection(Check only those areas evaluated)
Permit • Flow Measurement II Operations&Maintenance • Records/Reports
II Self-Monitoring Program El Facility Site Review • Effluent/Receiving Waters • Laboratory
Section D Summary of Finding/Comments(Attach additional sheets of narrative and checklists as necessary)
(See attachment summary)
Name(s)and Signature(s)of Inspector(s) Agency/Office/Phone and Fax Numbers Date
Paul DiMatteo WSRO WQ//336-776-9691/
Drado
Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date
4i
; 1 .w V . l -a� '��2 f
EPA Form 3560-3(Rev 9-94)Previous editions are obsolete
Page# 1
V
NPDES yr/mo/day Inspection Type 1
31 NCG590013 I11 121 18/09/06 117 18 LI
Section D•Summary of Finding/Comments(Attach additional sheets of narrative and checklists as necessary)
Page# 2
I'
Owner-Facili
Permit: NCG590013 tY• J D.Mackintosh,Jr VVTP
Inspection Date: 09/06/2018 Inspection Type: Compliance Evaluation
Operations & Maintenance Yes No NA NE
Is the plant generally clean with acceptable housekeeping? • 1=100
Does the facility analyze process control parameters,for ex: MLSS, MCRT,Settleable 01=I • 1=1
Solids, pH, DO, Sludge Judge, and other that are applicable?
Comment
Permit Yes No NA NE
(If the present permit expires in 6 months or less). Has the permittee submitted a new 00 • O
application?
Is the facility as described in the permit? M01=10
#Are there any special conditions for the permit? ❑ • ❑ ❑
Is access to the plant site restricted to the general public'? II ❑ ❑ ❑
Is the inspector granted access to all areas for inspection? • 000
Comment.
Record Keeping Yes No NA NE
Are records kept and maintained as required by the permit'? • 000
Is all required information readily available, complete and current'? U ❑ ❑ ❑
Are all records maintained for 3 years (lab reg. required 5 years)? • 01=10
Are analytical results consistent with data reported on DMRs? • ❑ ❑ ❑
Is the chain-of-custody complete'? 001:1 •
Dates,times and location of sampling ❑
Name of individual performing the sampling ❑
Results of analysis and calibration ❑
Dates of analysis ❑
Name of person performing analyses ❑
Transported COCs ❑
Are DMRs complete do they include all permit parameters? • 000
Has the facility submitted its annual compliance report to users and DWQ? ❑ ❑ • ❑
(If the facility is=or>5 MGD permitted flow) Do they operate 24/7 with a certified operator 01=1 • 1=1
on each shift'?
Is the ORC visitation log available and current'? • ❑ ❑ ❑
Is the ORC certified at grade equal to or higher than the facility classification'? • ❑ ❑ ❑
Is the backup operator certified at one grade less or greater than the facility classification? • ❑ ❑ ❑
Is a copy of the current NPDES permit available on site? • ❑ ❑ ❑
Page# 3
_•e
Permit: NCG590013 Owner-Facility: J D Mackintosh,Jr.WTP
Inspection Date: 09/06/2018 Inspection Type: Compliance Evaluation
Record Keeping Yes No NA NE
Facility has copy of previous year's Annual Report on file for review? ❑ ❑ • 0
Comment Field parameters are measured by the WTP Others are sent to the Burlington laboratory for
analysis. Burlington's lab bench sheets are kept at the lab. Therefore, I only verified the field
parameter data during the inspection.
Effluent Pipe Yes No NA NE
Is right of way to the outfall properly maintained? • ❑ 0 0
Are the receiving water free of foam other than trace amounts and other debris? • ❑ ❑ ❑
If effluent (diffuser pipes are required) are they operating properly? ❑ ❑ • 0
Comment:
Flow Measurement- Effluent Yes No NA NE
#Is flow meter used for reporting? • ❑ ❑ ❑
Is flow meter calibrated annually? • ❑ 0 0
Is the flow meter operational? • ❑ ❑ ❑
(If units are separated) Does the chart recorder match the flow meter? ❑ ❑ • ❑
Comment. Flow is measured using a Venturi meter in line with the effluent pump force main, and
recorded using SCADA. The meter's calibration is checked quarterly by ISI -the last
calibration was conducted in June, 2018.
Lagoons Yes No NA NE
Type of lagoons?
#Number of lagoons in operation at time of visit? 2
Are lagoons operated in? Parallel
#Is a re-circulation line present? ❑ ❑ ❑
Is lagoon free of excessive floating materials? • 0 ❑ ❑
#Are baffles between ponds or effluent baffles adjustable? ❑ 0 • ❑
Are dike slopes clear of woody vegetation'? • ❑ ❑ 0
Are weeds controlled around the edge of the lagoon? • ❑ ❑ ❑
Are dikes free of seepage? • ❑ ❑ ❑
Are dikes free of erosion? • 0 ❑ ❑
Are dikes free of burrowing animals'? • ❑ ❑ ❑
#Has the sludge blanket in the lagoon (s) been measured periodically in multiple • ❑ ❑ ❑
locations'?
#If excessive algae is present, has barley straw been used to help control the growth'? ❑ ❑ I ❑
Page# 4
Permit: NCG590013 Owner-Facility: J D Mackintosh,Jr WTP
Inspection Date: 09/06/2018 Inspection Type: Compliance Evaluation
Lagoons Yes No NA NE
Is the lagoon surface free of weeds? • ❑ ❑ ❑
Is the lagoon free of short circuiting? • ❑ ❑ ❑
Comment
De-chlorination Yes No NA NE
Type of system? Liquid
Is the feed ratio proportional to chlorine amount(1 to 1)? ❑ ❑ • ❑
Is storage appropriate for cylinders? ❑ ❑ • ❑
#Is de-chlorination substance stored away from chlorine containers? • ❑ ❑ ❑
Comment:
Are the tablets the proper size and type? ❑ ❑ • ❑
Are tablet de-chlorinators operational? ❑ ❑ U ❑
Number of tubes in use?
Comment- Calcium thiosulfate is added lust before the effluent pumps.
Laboratory Yes No NA NE
Are field parameters performed by certified personnel or laboratory'? U ❑ ❑ ❑
Are all other parameters(excluding field parameters) performed by a certified lab'? • ❑ ❑ ❑
#Is the facility using a contract lab? ❑ II ❑ ❑
#Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees ❑ ❑ ❑ II
Celsius)?
Incubator(Fecal Coliform) set to 44 5 degrees Celsius+/-0 2 degrees? ❑ ❑ • ❑
Incubator(BOD) set to 20.0 degrees Celsius+/- 1.0 degrees? ❑ ❑ • ❑
Comment: TRC is measured using a Hach DR 2800, which is calibrated yearly by Burlington's lab. The
last calibration was performed on 7/6/2018. pH probe is calibrated daily Temperature is
read with a digital thermometer. The thermometer should be checked yearly against an NIST
traceable thermometer, the deviation noted, and applied to readings.
Effluent Sampling Yes No NA NE
Is composite sampling flow proportional'? • ❑ ❑ ❑
Is sample collected below all treatment units? • ❑ ❑ ❑
Is proper volume collected? ❑ ❑ ❑ •
Is the tubing clean? ❑ ❑ U ❑
#Is proper temperature set for sample storage(kept at less than or equal to 6.0 degrees ❑ ❑ ❑ •
Celsius)?
Page# 5
i
Permit: NCG590013 Owner-Facility: J D Mackintosh,Jr WTP
Inspection Date: 09/06/2018 Inspection Type: Compliance Evaluation
Effluent Sampling Yes No NA NE
Is the facility sampling performed as required by the permit(frequency, sampling type • El ❑ El
representative)?
Comment Mr. Thomas said that the annual toxicity composite sample is accomplished by
hand-compositinq.A 250 ml lug is filled every hour for 24 hours, on a day that the pumps are
run continuously The sample is then combined.
Page# 6