Loading...
HomeMy WebLinkAboutNC0067008_Compliance Evaluation Inspection_20180921 . ,Lt_am I4,__;r.il .� 1 ,v, .. ROY COOPER NORTH CAROLINA Governor Environmental Quality , MICHAEL S.REGAN Secretary LINDA CULPEPPER RECEIVE®I0E�'r�l®� Interim Director — a September 21, 2018 ��� ® � 2�11 Water Resour on Mr. Nathan Miller, Chairman permitting Watauga County Board of Commissioners 814 West King Street, Suite 205 Boone, Nc 28607-0462 SUBJECT: Compliance Evaluation Inspection Old Cove Creek School WWTP NPDES Permit No. NC0067008 Watauga County Dear Mr. Miller, On September 11, 2018, Kelli Park of this office met with Josh Cagle to perform a Compliance Evaluation Inspection on the Old Cove Creek School's wastewater treatment • system. This type of inspection consists of two basic parts: an in-office file review and an on-site inspection of the treatment facility. The attached Environmental Protection Agency inspection form notes the areas that were evaluated for this inspection. The findings and observations are outlined below: I. Permit The NPDES permit became effective December 1, 2017, and expires on September 30, 2022. , II. Self-Monitoring Program A review of the monthly discharge monitoring reports (DMR) for the period January 2017 through August 2018 showed that the facility was in compliance with all permit limits. Grab samples are taken from the effluent pipe. Ill. Records/Reports The permit and visitation log were available during the inspection and show visitation times and plant conditions. Chain of custody forms are in good order. All required monitoring was performed per the frequencies specified in the NPDES permit. Miss Park 1:1E rosana ciwouraq Deouumrtmemm mwiuidtp\ North Carolina Department of Environmental Quality I Division of Water Resources Winston-Salem Regional Office 1450 Hanes Mill Road,Suite 300 I Winston-Salem,North Carolina 27103 336.776.9800 Old Cove Creek School,September 11,2018 noted no data transcription discrepancies from bench sheets to DMRs in her documentation review. Water Quality Labs maintains the documentation. IV. Flow Measurement The instantaneous flow is measured by collecting influent in a bucket for a minute of time. The effluent depth in the bucket is then measured, and the flow rate is manually calculated. V. Operations and Maintenance The-wastewater treatment plant appeared to be well maintained and operated. The ORC and backup ORC are sufficiently qualified to be running the plant. VL Facility Site Review All components of the 0.010 million gallons per day facility appeared to be functioning properly. Influent flows through a paper chamber before flowing into the plant. The paper chamber is pumped once a year by Triple T Pumping. The two aeration basins had a light brown color and a good earthy odor.All blowers were functioning properly and there were no dead spots. The dissolved oxygen is maintained around 2 milligrams per liter in the first aeration basin, and around 1 milligram per liter in the second aeration basin. The aeration basins are cycled 30 minutes on and 30 minutes off. Lime is added periodically to the aeration basins. The secondary clarifier had some floating solids but was discharging clear effluent. Effluent is disinfected by chlorine tablets placed in the weirs, and then dechlorination tablets are used in a contact chamber before the effluent leaves the plant. There is a clear path to where the effluent pipe discharges into the receiving stream. There used to be ultraviolet disinfection at this plant, but when the equipment went offline it was never repaired. It is suggested that it be brought back online. VII. Effluent/Receiving Waters The effluent from the facility was clear the day of inspection. Effluent was being discharged into an unnamed tributary to Cove Creek, class C waters, in the Watauga River basin. VIII. Sludge Maintenance and Handling Sludge in the clarifier was reported to be about 2.5 feet at the time of inspection and pumped about once a year due to low flow in the plant. Triple T Plumbing pumps the sludge. Records are reported to be maintained by Triple T Pumping. Sludge records need to be maintained on site starting immediately. 2 4 Old Cove Creek School,September 11,2018 • IX. Conclusions Mr. Cagle's efforts to comply with the permit are appreciated. If you have any questions regarding the inspection or this report, please contact Kelli Park or me at (336) 776-9800. Sincerely, ' ade.,-(. ,i- ,:g-4-- Sherri V. Knight, P.E. Regional Supervisor Water Quality Regional Operations Division of Water Resources • Attachments: BIMS EPA Water Compliance Inspection Report cc: Central Files WSRO NPS' 6ESUnit'' 3 United States Environmental Protection Agency • Form Approved. EPA Washington,D C 20460 OMB No 2040-0057 Water Compliance Inspection Report Approval expires 8-31-98 Section A National Data System Coding(i e.,PCS) Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type 1 E 2 Li 3 N00067008 I11 12 18/09/11 117 18 Lin 19 [ j 201 21111111 1111111111111111111111111 11111111111 166 Inspection Work Days Facility Self-Monitoring Evaluation Rating B1 QA - - Reserved - 671 1 70I I 711 I 72 731 1 174 751 1 1 1 1 1 1 180 Section B Facility Data Name and Location of Facility Inspected(For Industrial Users discharging to POTW,also include Entry Time/Date Permit Effective Date POTW name and NPDES permit Number) 12 00PM 18/09/11 17/12/01 Old Cove Creek School NCSR 1214 Exit Time/Date Permit Expiration Date 12 30PM 18/09/11 22/09/30 Sugar Grove NC 28679 • Name(s)of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) Other Facility Data /// Joshua Kenneth Cagle/ORC/828-898-6277/ Name,Address of Responsible Official/Title/Phone and Fax Number Contacted Glenda Evans,PO Box 338 Sugar Grove NC 28679/1828-297-2919/ No Section C Areas Evaluated During Inspection(Check only those areas evaluated) II Permit • Flow Measurement II Operations&Maintenance II Records/Reports Self-Monitoring Program II Facility Site Review Effluent/Receiving Waters Section D Summary of Finding/Comments(Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s)and Signature(s)of Inspector(s) Agency/Office/Phone and Fax Numbers Date Kelli A Park WSRO WQ//336-776-96891 cti 19 18. Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date At�� � � EPA Form 3560-3(Rev 9-94)Previous editions are obsolete Page# 1 • NPDES yr/mo/day Inspection Type 1 31 NC0067008 I11 121 18/09/11 117 18 I_ Section D Summary of Finding/Comments(Attach additional sheets of narrative and checklists as necessary) . Page# 2 J Permit: NC0067008 Owner-Facility: Old Cove Creek School Inspection Date: 09/11/2018 Inspection Type. Compliance Evaluation Operations & Maintenance Yes No NA NE Is the plant generally clean with acceptable housekeeping'? • 0 0 0 Does the facility analyze process control parameters, for ex. MLSS, MCRT, Settleable 0 ❑ • 0 Solids, pH, DO, Sludge Judge, and other that are applicable'? Comment. Permit Yes No NA NE (If the present permit expires in 6 months or less). Has the permittee submitted a new ❑ 0 IN 0 application'? Is the facility as described in the permit'? • ❑ 0 ❑ #Are there any special conditions for the permit'? ❑ • ❑ El Is access to the plant site restricted to the general public'? • ❑ 0 0 Is the inspector granted access to all areas for inspection'? • ❑ ❑ El Comment Record Keeping Yes No NA NE Are records kept and maintained as required by the permit'? • ❑ Cl El Is all required information readily available, complete and current'? ❑ • El El Are all records maintained for 3 years(lab reg required 5 years)? II ❑ ❑ ❑ Are analytical results consistent with data reported on DMRs? • 0 0 ❑ Is the chain-of-custody complete? • 0 ❑ ❑ Dates, times and location of sampling Name of individual performing the sampling • Results of analysis and calibration • Dates of analysis U Name of person performing analyses • Transported COCs • Are DMRs complete do they include all permit parameters'? • ❑ 0 El Has the facility submitted its annual compliance report to users and DWQ? ❑ El • ❑ (If the facility is=or>5 MGD permitted flow) Do they operate 24/7 with a certified operator 0 0 II El on each shift'? Is the ORC visitation log available and current'? • 0 El El Is the ORC certified at grade equal to or higher than the facility classification'? • 0 0 ❑ Is the backup operator certified at one grade less or greater than the facility classification'? • ❑ El El Is a copy of the current NPDES permit available on site'? • El ❑ ❑ Page# 3 • Permit: NC0067008 Owner-Facility: Old Cove Creek School Inspection Date: 09/11/2018 Inspection Type: Compliance Evaluation Record Keeping Yes No NA NE Facility has copy of previous year's Annual Report on file for review? 00 • 0 Comment: Log sheets missing for June 2018.the month that was being reviewed for bench sheet to DMR reporting. Aeration Basins Yes No NA NE Mode of operation Ext.Air Type of aeration system Diffused Is the basin free of dead spots? M ❑ ❑ ❑ Are surface aerators and mixers operational? 00 • 0 Are the diffusers operational? • 000 Is the foam the proper color for the treatment process? • 000 Does the foam cover less than 25%of the basin's surface'? • 000 Is the DO level acceptable? • 000 Is the DO level acceptable?(1.0 to 3 0 mg/I) • ❑ ❑ ❑ Comment Secondary Clarifier Yes No NA NE Is the clarifier free of black and odorous wastewater? • 000 Is the site free of excessive buildup of solids in center well of circular clarifier? 00110 Are weirs level? • 000 Is the site free of weir blockage? • 000 Is the site free of evidence of short-circuiting? • 000 Is scum removal adequate? 11 ❑ ❑ ❑ Is the site free of excessive floating sludge? • 000 Is the drive unit operational? ❑ ❑ E1 ❑ Is the return rate acceptable(low turbulence)? • 000 Is the overflow clear of excessive solids/pin floc? • 000 Is the sludge blanket level acceptable?(Approximately 1/4 of the sidewall depth) • ❑ ❑ ❑ Comment Disinfection-Tablet Yes No NA NE Are tablet chlorinators operational? • 000 Are the tablets the proper size and type? • 000 Number of tubes in use? 1 , Page# 4 Permit: NC0067008 Owner-Facility: Old Cove Creek School Inspection Date: 09/11/2018 Inspection Type: Compliance Evaluation Disinfection-Tablet Yes No NA NE Is the level of chlorine residual acceptable'? 00011 Is the contact chamber free of growth, or sludge buildup'? • 000 Is there chlorine residual prior to de-chlonnatlon? - ❑ ❑ ❑ 011 Comment De-chlorination Yes No NA NE Type of system? Tablet Is the feed ratio proportional to chlorine amount(1 to 1)? U 000 Is storage appropriate for cylinders'? U 000 #Is de-chlorination substance stored away from chlorine containers'? I ❑ ❑ ❑ Comment Are the tablets the proper size and type'? 1• 000 Are tablet de-chlorinators operational'? I 000 Number of tubes in use'? 1 Comment Effluent Pipe Yes No NA NE Is right of way to the outfall properly maintained'? • 11:100 Are the receiving water free of foam other than trace amounts and other debris'? • 000 If effluent (diffuser pipes are required) are they operating properly'? 00 • ❑ Comment: Page# 5