HomeMy WebLinkAboutWQ0034987_Correction_20180223Water Resources
ENVIRONMENTAL QUALITY
February 23, 2018
KRAIG A. WESTER13EEK— VICE PRESIDENT
MURPHY -BROWN LLC
POST OFFICE BOX 856
WARSAW, NORTH CAROLINA 28398
Dear Mr. Westerbeek:
ROY COOPER
Governor
MICHAEL S. REGAN
Secretary
LINDA CULPEPPER
Interim Director
Subject: Permit No. WQ0034987
Correction
Foxfire Trailer Wash
Wastewater Irrigation System
Bladen and Cumberland Counties
In accordance with a written request received November 27, 2017 from M. Kevin Weston, we are
forwarding herewith corrected Page 3 of Permit No. WQ0034987 issued March 9, 2017.
The correction to the subject permit is as follows:
1. The Bladenboro Garage Wash Bay has been added as an effluent source to Condition IE.7.
Please replace Page 4 of Permit No. WQ0034987 issued March 9, 2017 with the enclosed
corrected Page 4.
If you need additional information concerning this permit correction, please contact Nathaniel
Thornburg at (919) 807-6453 or nathaniel.thomburg@a ncdenr.gov.
Sincerely,
7 Linda Culpepper, Interim Director
Division of Water Resources
Enclosure
cc: Bladen County Health Department (Electronic Copy)
Cumberland County Health Department (Electronic Copy)
Fayetteville Regional Office, Water Quality Regional Operations Section (Electronic Copy)
M. Kevin Weston — Murphy -Brown LLC (Electronic Copy)
Beth Buffington — Protection and Enforcement Branch (Electronic Copy)
Digital Permit Archive (Electronic Copy)
Central Files
�'"Nothing Compares7�
State of North Carolina I Environmental Quality I Water Resources I Water Quality Permitting I Non -Discharge Permitting
1617 Mail Service Center I Raleigh, North Carolina 27699-1617
919-807-6332
11. The facilities permitted herein shall be constructed according to the following setbacks:
County
a. The setbacks for irrigation sites permitted under 15A NCAC 02T .0500 shall be as follows (all
distances in feet):
Easement
i. Any habitable residence or place of public assembly under separate ownership:
400
ii. Any habitable residence or place of public assembly owned by the Permittee
200
iii. Any private or public water supply source;
100
iv. Surface waters:
100
v. Groundwater lowering ditches:
100
vi. Surface water diversions:
25
vii. Any well with exception of monitoring wells:
100
viii. Any property line:
150'
ix. Top of slope embankments or cuts of two feet or more in vertical height;
15
x. Any water line from a disposal system;
10
xi. Subsurface groundwater lowering drainage systems;
100
xii. Any swimming pool;
100
xiii. Public right of way:
50
xiv. Nitrification field;
20
xv. Any building foundation or basement;
15
' Per setback waiver recorded in the Bladen and Cumberland County Register of Deeds, setbacks
from the wetted area to any property line has been reduced for the following:
Parcel No.
County
Deed Book / Page
Setback
Easement
20548
Bladen
758/153
0 feet
150 feet
20549
Bladen
758/153
0 feet
150 feet
1400-62-5185
Cumberland
10045/592
0 feet
150 feet
[15A NCAC 02T .0506(a)]
b. The setbacks for storage and treatment units permitted under 15A NCAC 02T .0500 shall be as
follows (all distances in feet):
i. Any habitable residence or place of public assembly under separate ownership; 100
ii. Any private or public water supply source; 100
iii. Surface waters; 50
iv. Any well with exception of monitoring wells: 100
v. Any property line: 50'
Per setback waiver recorded in the Bladen and Cumberland County Register of Deeds, setbacks
from storage and treatment units to any property line has been reduced for the following:
Parcel No.
County
Deed Book / Page
Setback
Easement
20548
Bladen
758/153
0 feet
50 feet
20549
Bladen
758/153
0 feet
50 feet
1400-62-5185
Cumberland
10045/592
0 feet
50 feet
[15A NCAC 02T .0506(b)]
W00034987 Version 2.0 Shell Version 151201 Page 3 of 9
III. OPERATION AND MAINTENANCE REQUIREMENTS
1. The facilities shall be properly maintained and operated at all times. The facilities shall be effectively
maintained and operated as a non -discharge system to prevent the discharge of any wastewater resulting
from the operation of this facility. The Permittee shall maintain an Operation and Maintenance Plan,
which at a minimum shall include operational functions, maintenance schedules, safety measures and
a spill response plan. [15A NCAC 02T .0507]
2. Upon the Water Pollution Control System Operators Certification Commission's (WPCSOCC)
classification of the subject non -discharge facilities, in accordance with 15A NCAC 08G .0200 the
Permittee shall designate and employ a certified operator in responsible charge (ORC) and one or more
certified operator(s) as back-up ORC(s). The ORC or their back-up shall visit the facilities in
accordance with 15A NCAC 08G .0200, and shall comply with all other conditions specified in the
previously cited rules. [15A NCAC 02T .0117]
3. A suitable year round vegetative cover shall be maintained at all times, such that crop health is
optimized, allows for even distribution of effluent and allows inspection of the irrigation system. [ 15A
NCAC 02T .0108(b)(1)]
4. Adequate measures shall be taken to prevent effluent ponding in or runoff from the irrigation sites listed
in Attachment B. [15A NCAC 02T .0108(b)(1)]
5. Irrigation shall not be performed during inclement weather or when the ground is in a condition that
will cause ponding or runoff. [15A NCAC 02T .0108(b)(1)]
6. All irrigation equipment shall be tested and calibrated at least once per permit cycle. Calibration records
shall be maintained at the facility for a period of no less than five years, and shall be made available to
the Division upon request. [15A NCAC 02T .0108(b)(1)]
7. Only effluent from the Foxfire Trailer Wash Facility and the Bladenboro Garage Wash Bay shall be
irrigated on the sites listed in Attachment B. [G.S. 143-215.1]
8. No automobiles or machinery shall be allowed on the irrigation sites except during equipment
installation or while maintenance is being performed. [15A NCAC 02T .0108(b)(1)]
9. Public access to the irrigation sites and wastewater treatment facilities shall be prohibited. [ 15A NCAC
02T .0505(q)]
10. The residuals generated from the wastewater treatment facilities shall be disposed or utilized in
accordance with 15A NCAC 02T .1100. The Permittee shall maintain a residual management plan
pursuant to 15A NCAC 02T .0508. [15A NCAC 02T .0508, 02T .1100]
11. Diversion or bypassing of untreated or partially treated wastewater from the treatment facilities is
prohibited. [15ANCAC 02T .05050)]
12. Freeboard in the 761,891 gallon clay lined lagoon shall not be less than two feet at any time. [15A
NCAC 02T .0505(d)]
13. A gauge to monitor waste levels in the 761,891 gallon clay lined lagoon shall be provided. This gauge
shall have readily visible permanent markings, at inch or tenth of a foot increments, indicating the
following elevations: maximum liquid level at the top of the temporary liquid storage volume;
minimum liquid level at the bottom of the temporary liquid storage volume; and the lowest point on
top of the dam. [15A NCAC 02T .0108(b)(1)]
W00034987 Version 2.0 Shell Version 151201 Page 4 of 9