HomeMy WebLinkAboutWQ0034350_Final Permit_20091020North Carolina
Beverly Eaves Perdue
Governor
NCDENR
Department of environment and Natural Resource:
Division of Water Quality
LEE SMITH—UTILiTiEs DIRECTOR
Coleen H. Sullins
Director
October 20, 2009
CITY OF HENDERSONVILLE
POST OFFICE Box 1670
HENDERSONVILLE, NORTH CAROLINA 28793
Dear Mr. Smith:
Dee Freeman
Secretary
Subject: Permit No, WQ0034350
Hendersonville WWTP
Conjunctive Reclaimed Water System
Henderson County
In accordance with your permit application request received July 8, 2009, and subsequent
additional information received September 3, 2009, we are forwarding herewith Permit No. WQ0034350,
dated October 20, 2009, to the City of Hendersonville for the construction and operation of the subject
conjunctive reclaimed water bulk distribution facilities.
This permit shall be effective from the date of issuance until December 31, 2015, and shall be
subject to the conditions and limitations as specified therein. Please pay particular attention to the
monitoring and utilization requirements listed in Attachments A and B. Failure to establish an adequate
system for collecting and maintaining the required operational information shall result in future
compliance problems.
Please note the monitoring requirements for BOD3i Ammonia, Total Suspended Solids and Fecal
Coliforms in Attachment A may use the required effluent data in the monitoring requirements for
NCO025534 (i.e., duplicate sampling is not required). The monitoring frequency and sampling type shall
be the same as those requirements in the NPDES permit (NC0025534).
Please also note the approved bulk reclaimed water uses listed in Attachment B. These uses are
shown in two tables: uses approved for the Permittee and their contracted service providers; and uses
approved for certified users.
If any parts, requirements or limitations contained in this permit are unacceptable, the Permittee
has the right to request an adjudicatory hearing upon written request within 30 days following receipt of
this permit. This request shall be in the form of a written petition, conforming to Chapter 150B of the
North Carolina General Statutes, and filed with the Office of Administrative Hearings at 6714 Mail
Service Center, Raleigh, NC 27699-6714. Unless such demands are made, this permit shall be final and
binding.
AQUIFER PROTECTION SECTION
1636 Mail Service Center, Raleigh, North Carolina 27695-1036
Location, 2728 Capital Boulevard, Raleigh, North Carolina 276604
Phone: 919-733-3221 1 FAX 1: 919-715.0588; FAX 2: 919.715-50481 Customer Service: 1.877-623.6748
Intemet: www.nmater�uality.org
An Equal Opeortun9iy, t AtfirmatEve Action EmplovE
IOre
nc fthCaroh11.a
6ral
Mr. Lee Smith
October 20, 2009
Page 2 of 2
If you need additional information concerning this matter, please contact Nathaniel Thornburg at
(919) 715-6160 or nathaniel.thornburg@ncdenr.gov.
Sincerely,
Coieen H. Sullins
cc: Henderson County Health Department
Asheville Regional Office, Aquifer Protection Section
Technical Assistance and Certification Unit
Permit File WQ0034350
Notebook File WQ0034350
NORTH CAROLINA
ENVIRONMENTAL MANAGEMENT COMMISSION
DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES
RALEIGH
CONJUNCTIVE RECLAIMED WATER SYSTEM PERMIT
In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as
amended, and other applicable Laws, Rules and Regulations
PERMISSION IS HEREBY GRANTED TO
City of Hendersonville
Henderson County
10IM1.1�
construction and operation of a conjunctive reclaimed water bulk distribution facility consisting of. a flow
meter; a turbidimeter; and a bulk fill station. Reclaimed water, following treatment and testing according
to the most recent issuance of the Hendersonville WWTP NPDES permit (NC0025534) and compliance
with the conditions provided herein, may be diverted to the permitted reclaimed water bulk fill station to
serve the Hendersonville WWTP, with no discharge of wastes to surface waters, pursuant to the
application received July 8, 2009, and subsequent additional information received by the Division of
Water Quality, and in conformity with the project plans, specifications, and other supporting data
subsequently filed and approved by the Department of Environment and Natural Resources and
considered a part of this permit.
This permit shall be effective from the date of issuance until December 31, 2015, and shall be subject to
the following specified conditions and limitations:
L SCHEDULES
1. The Asheville Regional Office, telephone number (828) 296-4500, shall be notified at least 48 hours
in advance (excluding weekends and holidays) of initial operation of the installed facilities such that
an in-place inspection can be made. Notification to the Aquifer Protection Section's regional
supervisor shall be made from 8:00 a.m. until 5:00 p.m. on Monday through Friday, excluding State
Holidays.
2. Plans and specifications for the turbidimeter and flow meter shall be prepared by a licensed North
Carolina Professional Engineer and submitted to the Asheville Regional Office 30 days prior to
installation.
3. No later than six months prior to the expiration of this permit, the Permittee shall request renewal of
this permit on official Division forms. Upon receipt of the request, the Division will review the
adequacy of the facilities described therein, and if warranted, will renew the permit for such period of
time and under such conditions and limitations as it may deem appropriate. Please note Rule 15A
NCAC 02T .0105(d) requires an updated site map to be submitted with the permit renewal
application.
WQ0034350 Version 1.0 Shell Version 091019 Page 1 of 8
111. PERFORMANCE STANDARDS
1. The subject non -discharge facilities shall be effectively maintained and operated at all times so there
is no discharge to surface waters, nor any contravention of groundwater or surface water standards.
In the event the facilities fail to perform satisfactorily, including the creation of nuisance conditions
due to improper operation and maintenance, or failure of the utilization areas to adequately assimilate
the reclaimed water, the Permittee shall take immediate corrective actions including Division required
actions, such as the construction of additional or replacement wastewater treatment facilities or
cessation of reclaimed water use at the failing utilization areas.
2. This permit shall not relieve the Permittee of their responsibility for damages to groundwater or
surface water resulting from the operation of this facility.
3. Bulk distributed reclaimed water shall not exceed the effluent limitations specified in Attachment A.
4. Construction of the bulk reclaimed water distribution system shall be done such that there is no
interruption of service at the existing wastewater treatment facility, nor shall result in an overflow or
bypass discharge to surface waters of the State.
S. Conjunctive reclaimed water bulk distribution uses shall be limited to the activities specified in
Attachment - Approved Bulk Distribution Uses.
6. The conjunctive use of reclaimed water permitted herein in no way negates, precludes, or invalidates
the most recent reissuance of the Permittee's NPDES permit (NC0025534), and the Permittee shall
continue to comply with all conditions provided for therein.
The following shall be requirements for the reclaimed water distribution, storage and utilization
facilities:
a. All reclaimed water valves, storage facilities and outlets shall be tagged or labeled to warn the
public or employees that reclaimed water is not intended for drinking. Where appropriate, such
warning shall inform the public or employees to avoid contact with reclaimed. water.
b. All reclaimed water piping, valves, outlets and other appurtenances shall be color -coded, taped or
otherwise marked to identify the source of the water as being reclaimed water.
i. All reclaimed water piping and appurtenances shall be either colored purple (i.e., Pantone
522) and embossed or integrally stamped or marked "CAUTION: RECLAIMED WATER —
DO NOT DRINK" or be installed with a purple (i.e., Pantone 522) identification tape or
polyethylene vinyl wrap. The warning shall be stamped on opposite sides of the pipe and
repeated every three feet or less.
ii. Identification tape shall be at least three inches wide and have white or black lettering on
purple (i.e., Pantone 522) field stating "CAUTION: RECLAIMED WATER — DO NOT
DRINK." Identification tape shall be installed on top of reclaimed water pipelines, fastened
at least every 10 feet to each pipe length and run continuously the entire length of the pipe.
iii. Existing underground distribution systems retrofitted for the purpose of distributing
reclaimed water shall be taped or otherwise identified as noted above. This identification
need not extend the entire length of the distribution system, but shall be incorporated within
10 feet of crossing any potable water supply line or sanitary sewer line.
c. All reclaimed water valves and outlets shall be of a type, or secured in a manner, that permits
operation by authorized personnel only.
d. Above -ground hose bibs (i.e., spigots or other hand -operated connections) shall not be present.
Hose bibs shall be located in locked below -grade vaults that shall be clearly labeled non potable.
As an alternative to the use of locked below -grade vaults with standard hose bibs services, hose
bibs, which can only be operated by a special tool or connected to a special hose connection, may
be placed in non -lockable underground services boxes clearly labeled non -potable.
WQ0034350 Version 1.0 Shell Version 091019 Page 2 of 8
8: The Permittee shall maintain an active cross -connection control program that shall have the following
minimum requirements:
a. No direct cross -connections shall be allowed between the reclaimed water and potable water
systems.
b. Where both reclaimed water and potable water are supplied to a reclaimed water utilization site, a
reduced pressure principle backflow preventer, an approved air gap separation or other Division
of Environmental Health approved device shall be installed at the potable water service
connection to the use area. The installation of the reduced pressure principle backflow prevention
device shall allow proper testing.
c. Where potable water is used to supplement a reclaimed water utilization system, the Permittee or
potable water supplier shall approve and regularly inspect the air gap separation.
9. Any exceedance of groundwater standards as a result of conjunctive reclaimed water bulk distribution
activities shall require action in accordance with 15A NCAC 02L.01 06.
10. The facilities permitted herein shall be constructed and/or operated according to the following
setbacks:
a. The setbacks for reclaimed utilization sites shall be as follows (all distances in feet):
i. Surface waters not classified SA:
ii. Surface waters classified SA:
iii. Any well with exception to monitoring wells
25
100
100
b. The setbacks for storage and treatment units shall comply with those in the Permittee's NPDES
permit (NC0025534).
M. OPERATION AND MAINTENANCE REQUIREMENTS
1. The facilities shall be properly maintained and operated at all times. The facilities shall be effectively
maintained and operated as a non -discharge system to prevent the discharge of any wastewater
resulting from the operation of this facility. The Permittee shall maintain an Operation and
Maintenance Plan pursuant to 15A NCAC 02T.0913, which at a minimum shall include:
a. Description of operation;
b. Description of anticipated maintenance;
c. Safety measures, including site restrictions;
d. Spill prevention and spill response plan;
e. Contact information for plant personnel, emergency responders, and regulatory agencies;
f. Approval procedures of users;
g. Operational requirements for users; and
h. If reclaimed water is to be stored for greater than 72 hours prior to use, include a description of
how reclaimed water quality standards will be meet at the time of use.
2. Upon the Water Pollution Control System Operators Certification Commission's (WPCSOCC)
classification of the subject non -discharge facilities, in accordance with 15A NCAC 08G .0200 the
Permittee shall designate and employ a certified operator in responsible charge (ORC) and one or
more certified operator(s) as back-up ORC(s). The ORC or their back-up shall visit the facilities in
accordance with 15A NCAC 08G .0200, and shall comply with all other conditions specified in the
previously cited rules.
3. Only reclaimed water from the Hendersonville WWTP (NC0025534) shall be utilized for bulk
distribution in the manner listed in Attachment B.
WQ0034350 Version 1.0 Shell Version 091019 Page 3 of 8
4. Public access to the reclaimed water utilization sites shall be controlled during active site use. Such
controls may include the posting of signs showing the activities being conducted at each site. Public
access to the wastewater treatment facilities shall be prohibited.
5. An education program shall be developed and implemented to inform City of Hendersonville
personnel of the proper use of bulk distribution reclaimed water.
An education program shall be developed and implemented to inform bulk distribution reclaimed
water users of the proper use of reclaimed water. Educational material shall be provided to all
individuals accepting bulk reclaimed water, and these materials shall be maintained consistent with
reclaimed water uses. All educational materials shall be made available to the Division upon request.
7. Where bulk reclaimed water is used for industrial purposes, disposal of the utilized reclaimed water
shall meet the conditions included in all State approved permits held by the industry (e.g., NPDES,
Non -Discharge or Pretreatment permits).
8. The Permittee shall develop and maintain a program of routine review and inspection of bulk
distribution reclaimed water users.
The Permittee shall approve tank truck drivers for participation in the bulk reclaimed water
distribution program prior to distribution of reclaimed water. In addition, the Permittee shall provide
training (bilingual as necessary) at a regular frequency to all tank truck drivers approved to participate
in the bulk reclaimed water distribution program. The training program shall include a system to
verify the tank truck driver comprehended the information provided in the training. These sessions
shall provide training on, but not limited to, the following topics:
a. Reclaimed water description and safety;
b. Approved and disapproved uses of reclaimed water;
c. Procedures for the application (including buffer maintenance), uses, and storage of reclaimed
water as well as the disposal of unused reclaimed water;
d. Procedures for spill prevention, countermeasures, and control as well as notification
requirements;
e. Personal safety and hygiene issues; and
f. Interaction with the general public.
10. Tank trucks used to transport reclaimed water shall meet the following requirements:
a. Tank trucks and other equipment used to distribute reclaimed water shall be clearly identified
with advisory signs. Signage could include but is not limited to "CAUTION: RECLAIMED
WATER — DO NOT DRINK", "NON -POTABLE WATER", or a combination of similar phrases.
Bilingual signage shall be used when necessary.
b. Tank trucks used to transport reclaimed water shall not be used to transport potable water.
c. Tank trucks used to transport reclaimed water shall not be filled through on -board piping or
removable hoses that may subsequently be used to fill tanks with water from a potable water
supply. Tank trucks owned and operated by the Permittee and dedicated to be filled by reclaimed
water only may be filled through on -board piping.
d. Tank trucks shall not have been used to haul septage, biosolids, or other waste or chemical
transport.
e. Tank trucks shall not have any type of removable container or portable bladder except if the
tank bladder is permanently labeled for reclaimed water use only and a letter from the truck
owner is submitted to the Permittee indicating that in no case shall any removable container or
portable bladder be used for both reclaimed and potable water at any time.
WQ0034350 Version 1.0 Shell Version 091019 Page 4 of 8
IV. MONITORING AND REPORTING REQUIREMENTS
Any Division required monitoring (including groundwater, plant tissue, soil and surface water
analyses) necessary to ensure groundwater and surface water protection shall be established, and an
acceptable sampling reporting schedule shall be followed.
2. Per 15A NCAC 02H .0800, a Division certified laboratory shall conduct all laboratory analyses for
the required effluent, groundwater or surface water parameters.
3. Flow distributed to the conjunctive reclaimed water system shall be continuously monitored, and
daily flow values shall be reported on Form NDMR.
The Permittee shall install and maintain an appropriate flow measurement device to ensure the
accuracy and reliability of flow measurement consistent with accepted engineering and scientific
practices. Selected flow measurement devices shall be capable of measuring flows with a maximum
deviation of less than ten percent from true flow; accurately calibrated at a minimum of once per year;
and maintained to ensure the accuracy of measurements is consistent with the selected device's
accepted capability. The Permittee shall maintain records of flow measurement device calibration on
file for a period of at least five years. At a minimum, documentation shall include:
a. Date of flow measurement device calibration,
b. Name of person performing calibration, and
c. Percent from true flow.
4. The Permittee shall monitor the bulk distributed reclaimed water from the subject facilities at the
frequencies and locations for the parameters specified in Attachment A.
5. The Permittee shall maintain adequate records tracking the amount of reclaimed water distributed. At
a minimum, these records shall include the following information:
a. Date and time of bulk distribution;
b. Name and drivers license number of truck operator;
c. Bulk fill certification number or equivalent (i.e., proof of certification provided to reclaimed
water user);
d. Name of end customer;
e. Intended use of bulk reclaimed water;
f. Volume of reclaimed water distributed per bulk distribution event;
g. Turbidity measurement results; and
h. Total volume of reclaimed water distributed each month.
6. Three copies of all monitoring data (as specified in Conditions IV.3. and IV.4.) on Form NDMR for
each PPI and three copies of all operation and disposal records (as specified in Condition IV.S.h.) on
Form NDAR-3 shall be submitted on or before the last day of the following month. If no activities
occurred during the monitoring month, monitoring reports are still required documenting the absence
of the activity. All information shall be submitted to the following address:
Division of Water Quality
Information Processing Unit
161.7 Mail Service Center
Raleigh, North Carolina 27699-1617
7. A maintenance log shall be maintained at this facility. This log shall be maintained at the facility for
a period of no less than five years, and shall be made available to the Division upon request. At a
minimum, this log shall include:
a. Date of calibration of flow measurement device;
b. Visual observations of the plant and plant site; and
c. Record of preventative maintenance (e.g., changing of equipment, adjustments, testing,
inspections and cleanings, etc.).
WQ0034350 Version 1.0 Shell Version 091019 Page 5 of 8
8. Noncompliance Notification;
The Permittee shall report by telephone to the Asheville Regional Office, telephone number (828)
2964500, as soon as possible, but in no case more than 24 hours, or on the next working day
following the occurrence or first knowledge of the occurrence of any of the following:
a. Any occurrence at the facility resulting in the treatment of significant amounts of wastes that is
abnormal in quantity or characteristic, including the !mown passage of a hazardous substance.
b. Any process unit failure (e.g., mechanical, electrical, etc.), due to known or unknown reasons,
rendering the facility incapable of adequate wastewater treatment.
c. Any facility failure resulting in a by-pass directly to receiving surface waters.
d. Any time self-monitoring indicates the facility has gone out of compliance with its permit
limitations.
e. Ponding in or runoff from inspected utilization sites.
Any emergency requiring immediate reporting (e.g., discharges to surface waters, imminent failure of
a storage structure, etc.) outside normal business hours shall be reported to the Division's Emergency
Response personnel at telephone number (800) 662-7956, (800) 858-0368, or (919) 733-3300.
Persons reporting such occurrences by telephone shall also file a written report in letter form within
five days following first knowledge of the occurrence. This report shall outline the actions taken or
proposed to be taken to ensure the problem does not recur.
V. INSPECTIONS
1. The Permittee shall provide adequate inspection and maintenance to ensure proper operation of the
wastewater treatment and utilization facilities.
2. The Permittee or their designee shall inspect the wastewater treatment and utilization facilities to
prevent malfunctions, facility deterioration and operator errors resulting in discharges, which may
cause the release of wastes to the environment, a threat to human health or a public nuisance. The
Permittee shall maintain an inspection log that includes, at a minimum, the date and time of
inspection, observations made, and any maintenance, repairs, or corrective actions taken. The
Permittee shall maintain this inspection log for a period of five years from the date of the inspection,
and this lag shall be made available to the Division upon request.
3. Any duly authorized Division representative may, upon presentation of credentials, enter and inspect
any property, premises or place on or related to the wastewater treatment and utilization facilities
permitted herein at any reasonable time for the purpose of determining compliance with this permit;
may inspect or copy any records required to be maintained under the terms and conditions ,of this
permit, and may collect groundwater, surface water or leachate samples.
4. In accordance with 15A NCAC 02T .0911(f) and to ensure compliance with the conditions of this
permit, the Permittee shall inspect the utilization sites of all reclaimed water users who obtain more
than 10,000 gallons per day of bulk distributed reclaimed water. Permittee inspection of these bulk
distribution reclaimed water utilization sites does not need to exceed one inspection per quarter. The
Permittee shall maintain records of these inspections for at least five years, and shall make them
available to the Division upon request.
WQ0034350 Version 1.0 Shell Version 091019 Pane 6 of 8
VI. GENERAL CONDITIONS
1. Failure to comply with the conditions and limitations contained herein may subject the Permittee to
an enforcement action by the Division in accordance with North Carolina General Statutes 143-
215.6A to 143-215.6C.
2. This permit shall become voidable if the permitted facilities are not constructed in accordance with
the conditions of this permit, the Division approved plans and specifications, and other supporting
documentation.
3. This permit is effective only with respect to the nature and volume of wastes described in the permit
application, Division approved pians and specifications, and other supporting documentation. No
variances to applicable rules governing the construction or operation of the permitted facilities are
granted, unless specifically requested and approved in this permit pursuant to 15A NCAC 02T
.0105(n).
4. The issuance of this permit does not exempt the Permittee from complying with any and all statutes,
rules, regulations, or ordinances, which may be imposed by other jurisdictional government agencies
(e.g., local, state, and federal). Of particular concern to the Division are applicable river buffer rules
in 15A NCAC 02B .0200; erosion and sedimentation control requirements in 15A NCAC Chapter 4
and under the Division's General Permit NCG010000; any requirements pertaining to wetlands under
15A NCAC 02B .0200 and 02H .0500; and documentation of compliance with Article 21 Part 6 of
Chapter 143 of the General Statutes.
5. In the event the permitted facilities change ownership or the Permittee changes their name, a formal
permit modification request shall be submitted to the Division. This request shall be made on official
Division forms, and shall include appropriate property ownership documentation and other supporting
documentation as necessary. The Permittee of record shall remain fully responsible for maintaining
and operating the facilities permitted herein until a permit is issued to the new owner.
6. The Permittee shall retain a set of Division approved plans and specifications for the life of the
facilities permitted herein.
7. The Permittee shall maintain this permit until all permitted facilities herein are properly closed or
permitted under another permit issued by the appropriate permitting authority pursuant to 15A NCAC
02T.01050).
8. This permit is subject to revocation or unilateral modification upon 60 days notice from the Division
Director, in whole or part for the requirements listed in 15A NCAC 02T .0110.
9. Unless the Division Director grants a variance, expansion of the permitted facilities contained herein
shall not be granted if the Permittee exemplifies any of the criteria in 15A NCAC 02T .0120(b).
10. The Permittee shall pay the annual fee within 30 days after being billed by the Division. Failure to
pay the annual fee accordingly shall be cause for the Division to revoke this permit pursuant to 15A
NCAC 02T .0105(e)(3).
Permit issued this the 20'h day of October 2009
NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION
// A,, �-
ree Sullins, Director
ivisi of Water Quality
By Authority of the Environmental Management Commission
Permit Number WQ0034350
WQ0034350 Version 1.0 Shell Version 091019 Page 7 of 8
THIS PAGE BLANK
WQ0034350 Version 1.0 She]] Version 091019 Page 8 of8
ATTACHMENT A - LIMITATIONS AND MONITORING REQUIREMENTS
PPI 001— WWTP Effluent
Permit Number: WQ0034350 Version: 1.0
EFFLUENT CHARACTERISTICS
EFFLUENT LIMITS
MONITORING
REQUIREMENTS
Parameter Description -PCS Code
Monthly Average
Mean Monthly Geometric
Daily Minimum
Daily Maximum
Measurement
Frequency
Sample
Type
SOD, 5 -Day (20 Deg. C) — 00310
10
mg/l
15
mg/I
See NCO025534
Composite
Coliform, Fecal MF_ M -FC Broth, 44.5C-31616
14
#/100 ml
25
#1100 ml
See NCO025534' Z
Grab
Flow, in Conduit or thru Treatment Plant— 50050
GPD
Continuous
Recording
Nitrogen, Ammonia Total (as N)-00610
4
mg/l
6
mg/l
See NCO025534'
Composite
Solids, Total Suspended--- 00530
5
111g/1
10
mgm
See NCO025534
Composite
Turbidity. HCH Turbidimeter — 00076
10
ntu
Continuous
Recording1
. The measurement frequency and sample type For BOD., Fecal Coliform, Ammottia and Total Suspended Solids shall be the same as those required in NC0025534, The reported results for these
parameters shall be the same as those reported in NCO025534 (i.e.. additional monitoring is not required for these parameters to comply with this permit).
2. Monthly average for Fecal Coliform shall be a geometric meati.
WQ0034350 Version I.0 Attachment A Page I of 2
THIS PAGE BLANK
WQ0034_ Version 1.0 Attachment A ;e 2 of 2
ATTACHMENT - APPROVED BULK DISTRIBUTION USES
City of Hendersonville — Hendersonville WWTP
Permit Number: WQ0034350 Version: 1.0
Table 1— Approved Bulk Fill Reclaimed Water Uses for City of Hendersonville Personnel and Contracted Service Providers
APPROVED USES'
ADDITIONAL REQUIREMENTS AND COMMENTS
Fire fighting and extinguishing
Shall meet Public Water Supply requirements
Reclaimed water distribution line pressure testing
Provided water is returned to a sanitary sewer, or used for other approved reclaimed water uses after testing
Vehicle and equipment washing
Provided no ponding or runoff occurs
'All users shall complete educational training and receive certification prior to receiving bulk reclaimed water.
Table 2 — Approved Bulk Fill Reclaimed Water Uses for Certified Users
APPROVED USES'
ADDITIONAL REQUIREMENTS AND COMMENTS
Concrete cutting
Decorative ponds and fountains draining to a sanitary
sewer
Hydro -seeding and fertilizer mixing
Industrial and commercial cooling or boiler blow down
water
Provided cooling or boiler blow down water is disposed of according to applicable permits
Industrial and commercial fire prevention systems where
there is separate non -potable Plumbing
Irrigation of public and private landscapes and turf
Make-up water for brine slurry or similar
Brine slurry to be road applied to prevent freezing
Make-up water for preparation of pesticide solutions or
similar
Use of reclaimed water does -not exempt user from meeting the use and disposal requirements of the created
solution.
Non -potable processes (e.g., concrete and compost
reduction)
Must meet compost permit requirements_
Sewer cleaning
Soil compaction and dust suppression
May include irrigation to clay or synthetic clay tennis courts, or similar
Street sweeping (not street washing)
Subsurface directional boring
Does not include borings into bedrock or installation of any wells subject to 15A NCAC 02C
Vehicle washing and power washing
Provided dual disinfection with UV and chlorination and that no ponding or runoff occurs
' All users shall complete educational training and receive certification prior to receiving bulk reclaimed water.
WQ0034350 Version 1.0 Attachment B
Page I of I
ADMINISTRATION
BUILDING CLARIFIER 2
AERATION BASIN 2 D r
Q
AERATION BASIN 1
CLARIFIER 1
BLOWERS
SCREENING AND
GRIT STRUCTURE
r
� r
SEPTAGE RECEIVING
K-74awal'
jeletv
pm
RECYCLE
PUMP STATION
EFFLUENT
FILTERS
INFECTION
i
INFLUENT
PUMPING
STATION
BUILDING
THICKENERS
i
t
FIGURE 1.3-1
WASTEWATER TREATMENT PLANT
City of Hendersonville WWTP
OnPr;ifinn anri MninlPnnnno Mpmia[
N1600 NOTES: i
f I
1. ALL STORM DRAIN PIPING !SHALL BE 15 IN. DIAMETER
UNLESS' OTHERWISE NOTED ON PLAN.
, I
2. SEE SHEET G-19 FOR STORMI DRAIN SCHEL IULE
N1700 —�3 _wALER_�-POTABLE-WATER_P�PIKGSMALL— -- - ---- - - ----- ---
BE 6 IN, DIAMETER UNLESS OTHERWISE NOTED. —
4• ALL PIPES SHALL HAVE A MINIMUM OF 3 FT. OF COVER �1
UNLESS OTHERWISE NOTED ON PLAN. I LoAd �' j A 4EAJ
5. ALL PRESSURE PIPING SHALL HAVE THRUST IBLOCKING GO
AT ALL TEES AND BENDS !UNLESS OTHERWISE NOTED.
I_
'N16006.--ALL-YARD-DRAINS-MD-WATER -LINES-Si•IAL4--IBE-PART------.—
OF CONTRACT 1.0. CONTRACT 1.3 SHALL EXTEND PIPES
5 FT. OUTSIDE OF STRUCTURES FOR CONNECTIONS BY
CONTRACT 1.0.
i 1 7. WATER TINES SHALL BE A MINIMUM 18 IN. ABOVE
I I AND JO FT. HORIZONTALLY FROM SEWER LIKES. '
I B. OUTLET PROTECTION SHAD BE PROVIDED AT' ALL
N 1800 LARED r fN D-5EeilON
FES 2
HYD
i DC 12 CB 13 - 14 1 I
LEGEVD
IN1400 4�L-rR 16 nCCB, 4,-T%r
---- 5T R#,f DRAIN D
ICB 15 HYD
P T WATER -- CB
- P�ABLE WATER CB 1' I HYD HYD
1420' C 20 I
------ S WATER I
N1300
2`
HYD IIB I HYD
YD lCB 10 CB 11 CB 2 2
FES 3� — — r L_ — — — — — DI 1 I
N1200 HYD
4h cg 2Z -o -
FH I Co 19 CB 0 HYD } CB I
_ 1 1 �11-1 TCB 1
.I
i 24 FES 1
N1I00
�► dL
, I
Ilo
I ~ 81LFOUR R�
� l h
N1000 I / / I EXISTING 8' 1 _ 1
MAB •
WATER UNE! ~�� CONNECT 70 ENO OF EXISTING �1FFI"13F-8 `PIPE
/ I I 8- POTABLE WATER LINE. FIRE HYDRANT, :M GATE
FES 4 CONTRACTOR TO VERIFY LOCATION I WITHVALVE. ANO B' ES PLUG
/ r � � � } WITH THRUST RESTRAINT.
C8 23 EXtSTOING
C8 Z4 IPLANT SITE
N900 E100 E200 E300 E4�0 E500E600 700 EEtOOO EttQO E100 E 1500 1
E 1600
Ku
..R FU Ift
• �� CAW THIS SHEET SUPEII =S SHEET C-11
r.u.. CJW 50 a SO' t00' SO4ED sT CKWUS WILLIS 12 SEPT 94 . . CITI' OF HENDERSONVILLE 1910.803.13E
„ C.JW W111iSENGINEERS WASTEWATER FACILITIES PLANT PIPING PLAN ,.T< �-�
Cirnam Gwl� JANUARY 1998
CS 261
ANO 10 FT. HORIZONTALLY fMUM ]LWLK lLINUt i
8. OUTLET PROTECTION SHALL BE PROVIDM AT ALL
FLARED END SECTIONS.
Ii
N1 9, 01 2 SHALL BE BUILT OVER THE EXISTING i5 ' RCP
B" AlN.-CONTBACTOR-Ta VE 1 [1CJ�TlON.
10. EXISTING PLANT PIPINGI NOT SHOWN.
I
11, THE CONTRACTOR SHALL COORINATE DECOMMISSIONING
OF EXISTING FACILITIES AND CONNECTION TO THE EXISTING
FACILITIES WITH THE ENGINEER.
.O 'E100EE30O E400
r%✓QA 78
I 1
I
E500 — E600 E700 E800 E
SEWER MH l 47 SEE SHEET
G-1 1
--- -- -- ---_ . _ LOC r4 �'� ,✓ d >� • -- - -
L a r1c(•'NS 2-ci Alfa
LECTION TOSANITARY +
SEWER MH 15. SEE SHEET
C-11
DCB 40 _.
�I
�JO '
6ii I • I i
k i
/! A
E1200 E1300 E1400 E1500 — E1600
a cow= CAW
C -w
G,,M,
e® CAWjr
50' 0 SO' 100'
i4.
WilliSENGINEERS
CITY OF HEPIDERSONVILLE
WASTEWATER FACILITIES
PLANT PIPING PLAN
1910.003.1�F
..R
jMlUARY 1996
TmIS SHEET SUPERCEDES SHEET C-13
S"ED BY 0wnE5 wILUS 17 SEPT oa
G-13