Loading...
HomeMy WebLinkAboutWQ0033097_Correction_20090911NC®ENR North Carolina Department of Environment and Natural Resources Division of Water Quality Beverly Eaves Perdue Coleen H. Sullins Governor Director September 11, 2009 Mr. Chris Daltorio — Managing Partner/COO Redtail-Gaston LLC 3608-200 Davis Drive #145 Morrisville, North Carolina 27560 Dear Mr. Daltorio: Dee reeman Secretary Subject: Permit No. WQ0033097 Eaton's Crossing Wastewater hrigation System Warren County In accordance with an email request from Mr. Doug Haggett, PE received on August 21, 2009; _ we are forwarding herewith a corrected permit description and a revised permit Attachment A for the permit issued on August 14, 2009. The corrections to these items are as follows: • The permit description has been revised to indicate that the ultraviolet disinfection unit has 8 bulbs (4 on each bank). The permit issued on August 14, 2009 mistakenly listed 10 UV bulbs. • Attachment A has been revised to indicate that the monthly average limit for Total Nitrogen is 8 mg/1. The permit issued on August 14, 2009 inadvertently contained the previous limit of 7 mg/1 which was used for the original permit issued on September 12, 2008. Please replace the permit description (Page 1 of 11) in the permit issued August 14, 2009 with the enclosed corrected permit description. In addition, please replace Attachment A in the permit issued August 14, 2009 with the enclosed corrected Attachment A. AQU!PER PRCTECTION SECT 10i. 1636 NW Service Center. Raleigh, Non[. Carolina 27699-1636 Loca-io-,: 2720 Capital Boulevard. P,aleig`,. Nor: Carolina 2760k Phone: 919-733-32211 FAX 1: 919-715-0588: FAX 2: 919-715-604F i ammer Service: 1-677.62. 6748 Interne,' www-rimaterouality.orc h Luc C?poun v + AfSLarz ae i,c,- --i Ernplc,e One Noi-tbCarolina Mr. Chris Daltorio September 11, 2009 Page 2 of 2 If you need additional information concerning this matter, please contact Lori Montgomery at (919) 715-6187 or lori.montgomery@ncdenr.gov. Sincerely, 4,.oleen H. Sullins cc: Warren County Health Department Raleigh Regional Office, Aquifer Protection Section Doug Haggett, PE — Haggett Engineering Associates (P.O. Box 15104, Wilmington, NC 28408) Permit File WQ0033097 Notebook File WQ0033097 NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES RALEIGH WASTEWATER IRRIGATION SYSTEM PERMIT In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules and Regulations PERMISSION IS HEREBY GRANTED TO Redtail-Gaston, LLC Warren County FOR THE construction and operation of a 24,690 gallon per day (GPD) wastewater treatment and wastewater irrigation facility consisting of: a dual train wastewater treatment plant with one (I) electromagnetic influent flow meter; one (1) 3mm fine screen with automatic auger and screenings press; one (1) 9,466 -gallon flow equalization zone with a coarse bubble diffusion system served by two (2) 30 cubic feet per minute (CFM) flow equalization blowers and two (2) 35 gallon per minute (GPM) equalization transfer pumps; two (2) anoxic zones with a total volume of 19,211 gallons with two (2) 2.1 horsepower (hp) submersible mixers per zone, and one (1) 2.5 gallon per hour (GPH) carbon source metering system per zone; two (2) aeration zones with a total volume of 1.3,488 gallons with a fine bubble aeration system served by dual (2) 245 CFM main plant blowers, and a 2.5 GPH alum metering system per zone for phosphorus removal; two (2) flat plate -type membrane bioreactor (MBR) units, each with a 15 square foot ($2) membrane area including an air scour system served by the main plant blowers, and two (2) 210 GPM anoxic recycle pumps per zone; one (1) 325 -gallon chemical storage tank for membrane cleaning; one (1) 1100 -gallon chemical storage tank for spent cleaning solution; one (1) 15,000 -gallon aerobic digester with a coarse bubble diffuser system served by the main plant blowers; one (1) ultraviolet (UV) disinfection unit with two (2) banks of four (4) UV lamps each; a concrete lift station with dual (2) 70 GPM transfer pumps; one (1) electromagnetic effluent flow meter; a 125 kW auxiliary generator for backup power supply to essential treatment units; one (1) 0.9 million gallon (MG) synthetically lined wet weather storage pond; dual (2) 124 GPM irrigation dosing pumps; 10.7 acres of spray irrigation area; and all piping, valves, and appurtenances, to serve 241 bedrooms and a pool house, with no discharge of wastes to surface waters, pursuant to the application received June 9, 2009, and subsequent additional information received by the Division of Water Quality, and in conformity with the project plans, specifications, and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources and considered a part of this permit. This permit shall be effective WQ0033097 issued September limitations: from the date of issuance until August 31, 2013, shall void Permit No. 12, 2008 and shall be subject to the following specified conditions and WQ0033097 Version 1.0 Shell Version 090806 Page 1 of 11 L SCHEDULES 1. In accordance with 15A NCAC 02T .0 116, upon completion of construction and prior to operation of this permitted facility, a certification (attached) shall be submitted from a licensed North Carolina Professional Engineer certifying that the permitted facility has been installed in accordance with this permit, Division approved plans and specifications, and other supporting documentation, including the location of all monitoring wells as applicable. If this project is to be completed in phases and partially certified, the Permittee shall retain the responsibility to track further_ construction approved under the same permit, and shall provide a final certificate of completion once the entire project has been completed. Mail the Certification to the Division of Water Quality, Aquifer Protection Section, 1636 Mail Service Center, Raleigh, NC 27699-1636. 2. The Raleigh Regional Office, telephone number (919) 791-4200, shall be notified at least 48 hours in advance (excluding weekends and holidays) of operation of the installed facilities such that an in- place inspection can be made. Notification to the Aquifer Protection Section's regional supervisor shall be made from 8:00 a.m. until 5:00 p.m. on Monday through Friday, excluding State Holidays. 3. A gauge to monitor waste levels in the wet weather storage pond shall be installed prior to operation. Caution shall be taken not to damage the integrity of the liner (if present) when installing the gauge. 4. No later than six months prior to the expiration of this permit, the Permittee shall request renewal of this permit on official Division forms. Upon receipt of the request, the Division will review the adequacy of the facilities described therein, and if warranted, will renew the permit for such period of time and under such conditions and limitations as it may deem appropriate. Please note Rule 15A NCAC 02T .0105(d) requires an updated site map to be submitted with the permit renewal application. U. PERFORMANCE STANDARDS 1. The subject non -discharge facilities shall be effectively maintained and operated at all times so there is no discharge to surface waters, nor any contravention of groundwater or surface water standards. In the event the facilities fail to perform satisfactorily, including the creation of nuisance conditions due to improper operation and maintenance, or failure of the irrigation areas to adequately assimilate the effluent, the Permittee shall take immediate corrective actions including Division required actions, such as the construction of additional or replacement wastewater treatment or disposal facilities. 2. This permit shall not relieve the Permittee of their responsibility for damages to groundwater or surface water resulting from the operation of this facility. 3. Effluent limitations shall not exceed those specified in Attachment A. 4. Application rates, whether hydraulic, nutrient or other pollutant, shall not exceed those specified in Attachment B. 5. The Operational Agreement (attached) between the Permittee and the Environmental Management Commission is incorporated herein by reference and shall be a condition of this permit. Noncompliance with the terms of the Operational Agreement shall subject the Permittee to all sanctions provided by North Carolina General Statutes §143-215.6A to §143-215.6C for violation of or failure to act in accordance with the terms and conditions of this permit. 6. The irrigation system shall be connected to a rain or moisture sensor, which shall indicate when effluent application is not appropriate in accordance with Conditions IIIA. and 111.5. of this permit. WQ0033097 Version 1.0 Shell Version 090806 Page 2 of 11 ATTACHMENT A - LIMITATIONS AND MONITORING REQUIREMENTS PPI 001--- WWTP Effluent Permit Number: WQ0033097 Version: 1.1 EFFLUENT CHARACTERISTICS EFFLUENT LIMITS MONITORING REQUIREMENTS Parameter Description -PCS Code Monthly Average Mean Monthly Geometric Daily Minimum Daily Maximum Measurement Frequency Sample Type Flow, in conduit or thru treatment plant - 50050 24.960 GPD Continuous Recording I301.), 5 -Day (20 Deg. Q - 00310 30 mg/l 2 X Month Grab Solids, Total Suspended - 00530 30 Ing/l 2 X Month Grab Nitrogen, Ammonia Total (as N) - 00610 2 X Month Grab Nitrogen. Nitrate Total (as N) - 00620 2 X Month Grab Nitrogen, Total (as N) ° - 00600 8 mg/l 2 X Month Grab Phosphorus. Total (as P) - 00665 1 n1g/1 2 X Month Grab Coliform, Fecal MF, M -FC Broth. 44.5C - 31616 (geom.meau) 2 X Month Grab p[I - 00400 6.0 9.0 Daily - weekdays Grab Solids, Total dissolved- 180 Deg.0 - 70300 3 X Year 2 Grab Chloride (as Cl) - 00940 3 X Year Z Grab 1. Limits for Total Nitrogen and "notal Phosphorus are based on agronomic limitations. 2. 3 X Year sampling shall he conducted in March, July- and November. WQ0033097 Version I.1 Attachment A Page I of I THIS PAGE BLANK