Loading...
HomeMy WebLinkAboutWQ0031598_Final Permit_20071221N\VWN4 ATE Michael F. Easley, Governor �0 Rp William G. Ross Jr., Secretary North Carolina Department of Environment and Natural Resources _ Coleen H. Sullins, Director Q -�' Division of Water Quality December 21, 2007 Mr. David Ferrell Village Investment, LLC 1600 Morrrisville Carpenter Road Cary, North Carolina 27519 Subject: Permit No. WQ0031598 Highway 751 Subdivision Lot #11 Surface Irrigation Facility Chatham County Dear Mr. Ferrell: In accordance with your permit application request received April 11, 2007 and additional information received October 12, 2007, and December 5, 2007, we are forwarding herewith Permit No. WQ0031598, dated December 21, 2007, to Village Investment, LLC for the construction and operation of the subject single family wastewater treatment and surface irrigation facilities. This permit shall be effective from the date of issuance until November 30, 2012 and shall be subject to the conditions and limitations as specified therein. Please pay particular attention to the monitoring requirements in this permit. Failure to establish an adequate system for collecting and maintaining the required operational information will result in future compliance problems. Please pay particular attention to permit condition 1.15. which requires that an adequate water supply well be installed prior to the start of construction of the disposal system under this permit. Please pay particular attention to permit condition 1.16. which requires recording of the deed for this lot and submittal of a copy of the deed to the Aquifer Protection Section of the Division of Water Quality prior to the start of construction of the disposal system. Also, please pay particular attention to permit condition 1.17 which specifies procedures to be followed in the addition of fill material to the irrigation area and to permit condition I.18 which requires preparation and submittal of a soils report following completion of the fill operation. An extension shall be requested, by the permittee, at least six (6) months prior to the expiration of this permit. Upon receipt of the request the Commission will review the adequacy of the facility described therein and, if warranted, will extend the permit for such period of time and under such conditions and limitations as it may deem appropriate. If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within thirty (30) days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 150B of the North Carolina General Statutes, and fled with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, NC 27699-6714. Unless such demands are made this permit shall be final and binding. Aquifer Protection Section 1636 Mail Service Center Internet: www.newater uali .or Location: 2728 Capital Boulevard An Equal Opportun4lAffirmaWe Action Employer— 56% Recyded110% Post Consumer Paper NorthCaralina Naturallff Raleigh, NC 27699-1636 Telephone: (919) 733-3221 Raleigh, NC 27604 Fax 1: (919) 715-0588 Fax 2: (919) 715-6048 Customer Service: (877) 623-6748 One set of approved plans and specifications is being forwarded to you. Please contact Duane Leith by email at duane.leith@nemail.net or by phone at (919) 715-6186 if you need additional information concerning this matter, Sincerely, O'e���, U46 ---s Coleen H. Sullins cc; Chatham County Health Department Raleigh Regional Office - Aquifer Protection. Section Technical Assistance and Certification Unit Gary MacConnell, P.E., MacConnell & Associates, P.C. G. Christopher Murray LSS, Soil & Environmental Consultants, PA Andy Siegner III, R.S., Environmental Health DirectorTwitirlctter) APS Central Files (WQ0031598) LAU Files NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES RALEIGH SINGLE FAMILY RESIDENCE SURFACE IRRIGATION PERMIT In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations PERMISSION IS HEREBY GRANTED TO Village Investment, LLC Chatham County FOR THE construction and operation of a 480 gallon per day (GPD) surface irrigation wastewater treatment and disposal system consisting of a 1,500 gallon baffled septic tank with effluent filter, a partially in -ground E -Z Treat 60 square foot by 3 foot deep synthetic media wastewater treatment filter with a 2,400 gallon recirculation tank and 30 GPM recirculation pump, a 4,650 gallon storage/pump tank, a 27 GPM pump with a high water alarm light and buzzer, two 10 GPM ultraviolet light disinfection units installed in series, a 17,283 square foot drip irrigation area consisting of 6 zones of 2,736 to 3,405 square feet each with 4 to 5 drip lines 208 to 236 feet long on a 3 foot spacing and all associated piping and appurtenances, to serve the Village Investment, LLC residence located at Lot 11 in the Village Investment Subdivision, Hwy 751, Apex, North Carolina, 27502, with no discharge of wastes to the surface waters, pursuant to the application received April 11, 2007, and additional information received October 12, 2007, and December 5, 2007, and in conformity with the project plan, specifications, and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources and considered a part of this permit. This permit shall be effective from the date of issuance until November 30, 2012 and shall be subject to the following specified conditions and limitations: I. PERFORMANCE STANDARDS 1. Upon completion of construction and prior to operation of this permitted facility, a certification must be received from a professional engineer certifying that the permitted facility has been installed in accordance with this permit, the approved plans and specifications, and other supporting materials. If this project is to be completed in phases and partially certified, you shall retain the responsibility to track further construction approved under the same permit, and shall provide a final certificate of completion once the entire project has been com leted. Mail the Certification to the Groundwater Protection Unit, 1636 Mail Service Center, Raleigh, NC 27699-1636. 2. The Raleigh Regional Office, telephone number (919) 791-4200, shall be notified at least forty-eight (48) hours in advance of operation of the installed facilities so that an in-place inspection can be made. Such notification to the regional supervisor shall be made during the normal office hours from 8:00 a.m. until 5:00 p.m. on Monday through Friday, excluding State Holidays. 3. The surface irrigation facilities shall be effectively maintained and operated at all times so that there is no discharge to surface waters, nor any contamination of ground waters, which will render them unsatisfactory for normal use. In the event that the facilities fail to perforin satisfactorily, including the creation of nuisance conditions or failure of the irrigation area to adequately assimilate the wastewater, the Permittee shall take immediate corrective actions including those actions that may be required by the Division of Water Quality, such as the construction of additional or replacement wastewater treatment and disposal facilities. 4. The issuance of this permit shall not relieve the Permittee of the responsibility for damages to surface or ground waters resulting from the operation of this facility. 5. A leakage test shall be performed on the septic tank and storage/pump tank(s) to insure that any exfiltration occurs at a rate, which does not exceed twenty (20) gallons per twenty-four (24) hours per 1,000 gallons of tank capacity. The Engineer's Certification will serve as proof of compliance with this condition. b. If excavation into bedrock is required for the installation of the septic tank, recirculation tank, pump tank or other components, the excavation shall be lined with a 10 -mil synthetic liner. 7. A sanitary tee and filter shall be installed on the effluent pipe of the septic tank. The Engineer's Certification will serve as evidence that these specifications have been met. 8. The residuals generated from these treatment facilities must be disposed in accordance with General Statute 143-215.1 and in a manner approved by the Division. 9. Diversion or bypassing of the untreated wastewater from the treatment facilities is prohibited. 10. The following setbacks shall be maintained: a. 100 feet between the wetted area and any residence or places of public assembly under separate ownership, b. 50 feet between the wetted area and property lines, c. 100 feet between wetted area and wells, d. 100 feet between the wetted area and drainage ways or surface water bodies, e. 50 feet between the wetted area and public right of ways, f. 100 feet between the wetted area and any swimming pool, g. 15 feet between the wetted area and any building foundation or basement, h. 100 feet between the treatment/storage units and any wells, with the exception of monitoring wells, and i. 50 feet between the treatment units and property lines. 11. The pump tank(s) shall have functional audible and visual high water alarms that are external to any structure. 12. The disposal system shall be connected to a rain or moisture sensor that shall indicate when wastewater application is not appropriate in accordance with Condition 11(4). 2 13. The existing vegetation on the drip irrigation site shall not be cleared nor disturbed except to the extent necessary to provide the required fill material or to install the dripline where no fill is required. 14. All tank access risers shall extend at lest six (6) inches above finished grade and shall be provided with properly secured covers. 15. The water supply well for the site shall be installed and determined to be adequate to meet the requirements of the proposed residence prior to the start of construction of the wastewater disposal system under this permit. 16. The subdivision of the property on which this wastewater disposal system is to be installed shall be completed and the deed for this lot recorded with the local land recording authority. A copy of the deed and a plat or survey map of the property shall be submitted to the Groundwater Protection Unit of the Aquifer Protection Section, at 1636 Mail Service Center, Raleigh, North Carolina 27699-1636 prior to the start of construction of the wastewater disposal system under this permit. IT The installation of fill material over a portion of the wetted area as specified in the plans shall only occur when soil moisture conditions are sufficiently low to ensure that compaction of the underlying subsoil and rutting of the soil surface will not occur. Fill material shall have USDA soil textures classified as sandy loam or loam. Fill material shall not contain fibrous organics, building rubble or other debris. The fill material shall be placed over the application area only after proper preparation of the original ground surface. Heavy vegetative cover or organic litter shall be removed before the fill material is added or incorporated. The first layer of fill material and the existing soil shall be mixed to a depth of six inches below the interface. The type of fill material shall be approved by a licensed soil scientist prior to placement. The fill area shall be shaped to shed surface water and shall be stabilized with a vegetative cover to prevent erosion. The side slope of the fill shall not exceed a rise to run ratio of 1:4. After placement, a soil test of the fill material skull be perforrned to determine the addition of lime and fertilizer required for the specific type of vegetation to be established as a vegetative cover. 18. Within 15 days from the date of completion of the addition of fill material, a. post -construction soils report shall be conducted to confirm that the fill addition was done appropriately and that the hydraulic loading rates specified in Permit Condition 11.6 remain appropriate. The completed, signed, sealed soils report shall be submitted to the Groundwater Protection Unit of the Aquifer Protection Section, at 1636 Mail Service Center, Raleigh, North Carolina 27699-1636 prior -to the start of construction of the wastewater disposal system under this permit. II. OPERATION AND MAINTENANCE REQUIREMENTS I . The facilities shall be properly maintained and operated at all times. 2. Upon classification of the wastewater treatment and surface irrigation facilities by the Water Pollution Control System Operators Certification Commission (WPCSOCC), the Permittee shall designate and employ a certified operator to be in responsible charge (ORC) and one or more certified operator(s) to be back-up ORC(s) of the facilities in accordance with 15A NCAC 8G .0201. The ORC shall visit the facilities in accordance with 15A NCAC 8G .0204 or as specified in this permit and shall comply with all other conditions specified in these rules. 3. A suitable year round vegetative cover or leaf litter cover shall be maintained over the disposal area. 4, Irrigation shall not be performed during inclement weather or when the ground is in a condition that will cause runoff. 5. Adequate measures shall be taken to prevent wastewater runoff from the irrigation field. 6. The application rate shall not exceed a cumulative loading of 16.5 inches over any twelve (12) month period at an instantaneous application rate not to exceed 0.70 inches per hour. 7. The facilities shall be effectively maintained and operated as a non -discharge system to prevent the discharge of any wastewater resulting from the operation of this facility. 8, No type of wastewater other than that from the Village Investment, LLC, Lot 11 residence at the Village Investment, LLC subdivision, located on Highway 751 in Apex, North Carolina, zip code 27502, shall be emitted onto the irrigation area. 9. No traffic or equipment shall be allowed on the disposal area except while installation occurs or while normal maintenance is being performed. -10. The irrigation field shall be fenced with at least a two -strand wire fence. 11. Wastewater treatment units open to the atmosphere shall have restricted access and pump control panels shall be locked. 12. The Pennittee is responsible for the operation and maintenance of the entire treatment and disposal system including, but not limited to, the following items: a. The septic tank shall be checked annually and pumped out as needed. The septic tank effluent filter shall be checked and cleaned at the sane frequency of the septic tank. b. The ultraviolet disinfection unit shall be checked every week. The lamp shall be cleaned and/or replaced as necessary to ensure proper disinfection. c. The storage, pump, and alarm systems shall be inspected monthly. Any sludge or scum layer accumulating in the pump/storage tank(s) shall be removed at the same interval as the septic tank is cleaned out. d. The system shall be inspected monthly to make certain of the proper operation of the drip line, that the vegetative growth allows a proper drip pattern, that the soil is assimilating the disposed treated wastewater with no surface runoff, and that no objectionable odors are being generated. III. MONITORING AND REPORTING REQUIREMENTS 1. Any monitoring deemed necessary by the Division to insure surface and ground water protection will be established and an acceptable sampling reporting schedule shall be followed. 2. The Permittee shall maintain records of all maintenance performed on the system and irrigation area, as required in Condition II(12) for a minimum of five years. This information shall be provided to the Division upon request. 3. Noncompliance Notification: rd The Permittee shall report by telephone to the Raleigh Regional Office, telephone number (919) 791- 4200, as soon as possible, but in no case more than 24 hours or on the next working day following the occurrence or first knowledge of the occurrence of any of the following: a. Any process unit failure, due to known or unknown reasons, that renders the facility incapable of adequate wastewater treatment, such as mechanical or electrical failures of pumps, emitters, etc.; or b. Any failure of a pumping station or treatment facility resulting in a by-pass directly to receiving waters without treatment of all or any portion of the influent to such station or facility. Occurrences outside normal business hours may also be reported to the Division's Emergency Response personnel at telephone number (800) 858-0368 or (919) 733-3300. Persons reporting such occurrences by telephone shall also file a written report in letterform within five (5) days following first knowledge of the occurrence. This report must outline the actions taken or proposed to be taken to ensure that the problem does not recur. IV. INSPECTIONS 1. Adequate inspection, maintenance, and cleaning shall be provided by the Permittee to insure proper operation of the subject facilities. 2. Any duly authorized officer, employee, or representative of the Division may, upon presentation of credentials, enter and inspect any property, premises or place on or related to the disposal site or facility at any reasonable time for the purpose of determining compliance with this permit, may inspect or copy any records that must be maintained under the terms and conditions of this permit, and may obtain samples of groundwater, surface water, or leachate. V. GENERAL CONDITIONS 1. This permit shall become void unless the facilities are constructed in accordance with the conditions of this permit, the approved plans and specifications, and other supporting data. 2. This permit is effective only with respect to the nature and volume of wastes described in the application and other supporting data. This permit is not transferable. In the event there is a desire for the facilities to change ownership, or there is a name change of the Permittee, a formal permit request must be submitted to the Division accompanied by documentation from the parties involved, and other supporting materials as may be appropriate, The approval of this request will be considered on its merits and may or may not be approved. 4. Upon the availability of a municipal or regional sewerage collection system, the subject wastewater treatment facilities shall be abandoned and all wastewater discharged into the municipal or regional sewerage system. 5. Failure to abide by the conditions and limitations contained in this permit may subject the Permittee to an enforcement action by the Division in accordance with North Carolina General Statute 143- 215.6A to 143.215.6C. 5 6. The issuance of this permit does not preclude the Permittee from complying with any and all statutes, rules, regulations, or ordinances, which may be imposed by other government agencies (local, state, and federal), which have jurisdiction. 7. This permit may be revoked if the Permittee fails to abide by the conditions of the "Operation and Maintenance Agreement" previously signed by the Permittee. The Permittee shall retain a set of approved plans, specifications and operation and maintenance manual of the subject facility for the life of the project. 9. The Permittee shall pay the annual administering and compliance fee within 30 days of being billed by the Division. Failure to pay the fee accordingly may cause the Division to initiate action to revoke this permit as specified by 15A NCAC 2T .0105 (e)(3). 10. The Permittee, at least six (6) months prior to the expiration of this permit, shall request its extension. Upon receipt of the request, the Commission will review the adequacy of the facilities described therein, and if warranted, will extend the Permit for such period of time and under such conditions and limitations, as it may deem appropriate. Permit issued this the 21st day of December, 2007. NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION Z)6z, --�, v-v*s oleen H. Sullins, Director . . Drvzsron of Water Quality By Authority of the Environmental Management Commission Permit Number WQ0031598 on Permit No. WQ0031598 December 21, 2007 ENGINEER'S CERTIFICATION Partial Final 1, , as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (periodically, weekly, full time) the construction of the project, Project Name Location and County for the Permittee hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance and intent of this permit, the approved plans and specifications; and other supporting materials. Signature Date 7 Registration No. VICINITY MAP OPERATION AND MAINTENANCE AGREEMENT SINGLE FAMILY RESIDENCE SURFACE IRRIGATION SYSTEM DIVISION OF WATER QUALITY Property Owner(s): Villa e Investments Mailing Address: 1600 Morrisville Carpenter Road Caa, NC 27519 Facility Address: Disposal Method: ❑ SPRAY IRRIGATION J J DRIP IRRIGATION (Check I One) I County: Chatham Permit No. RECEIVED 1 DEN 1 QWC1 AQUJPFR-VRniFrMT1( N S CTIOH I/We agree to operate and maintain the wastewater treatment system as follows: OCT 12 2001. 1. The Permittee is responsible for the operation and maintenance of the entire treatment and disposal system including, but not limited to, the following items: a. The septic tank shall be checked annually and pumped out as needed. The effluent filter shall be checked and cleaned at the same frequency of the septic tank. b. The sand filter surface shall be raked and leveled every six (6) months and any vegetative growth shall be removed by hand [accessible sand filters only]. c. Check one: U The tablet chlorinator shall be checked every week. Tablets shall be added so as to provide proper chlorination. J The ultraviolet disinfection unit shall be checked every week. The Iamp shall be cleaned and/or replaced to ensure proper disinfection. d. The storage, pump, and alarm systems shall be inspected monthly. The scum layer shall be removed at the same time interval as the septic tank is pumped out. e. The irrigation system shall be inspected monthly to make certain of proper operation, that vegetative growth does not interfere with the system inspection or operation, that the soil is assimilating the disposed treated wastewater with no surface runoff, and that no objectionable odors are being generated. 2. Failure of the Permittee to properly operate this system is subject to a penalty up to $25,000 per day. 3. Failure to meet the permit conditions or violation of the State's surface or groundwater regulations will require evacuating the dwelling and may void the permit. I/We understand the above r ii -em n and gree to these terms as part of the issued permit. C r- 0��n� Signature(s): Date: �� d �t ��_�Q.__:...!LMA- � •' d0POAki PU13LXC SFR PS ���/11�11!!!I 11111111U1� Date: Date: r7/1:3 02 Commission Expiration: