Loading...
HomeMy WebLinkAboutWQ0031506_Correction_20131017AV,I�Alr NCDENR North Carolina Department of Environment and Natural Resources Division of Water Resources Water Quality Programs Pat McCrory Thomas A. Reeder Governor Director October 17, 2013 Mr. John Kiviniemi — Wastewater Treatment and BiosoIids Recycling Manager Orange Water & Sewer Authority 400 Jones Perry Road Carrboro, NC 27510 Subject: Permit No. WQ0031506 Correction John E. Skvarla, ill Secretary Orange Water & Sewer Authority Mason Farm WWTP Residuals Conjunctive Reclaimed Water Utilization System Orange County Dear Mr. Kiviniemi: It has been brought to our attention that the permit issued to the Orange Water and Sewer Authority on July 9, 2013 contains some errors. The following corrections have been made to the permit: The monitoring parameters of "Plow, in conduit or thru treatment plant" (PCS Code 50050) and "Nitrate plus Nitrite Total 1 DET. (as N)" (PCS Code 00630) have been removed from Attachment A and from the PPI 001 NDMR 03-12 Non -Discharge Monitoring Report (NDMR) Form. The monitoring parameters of "Plant Available Nitrogen" (PCS Code WQ 09) and "Reclaimed Water Distributed" (PCS Code WQ 01) have also been removed from the PPI 001 NDMR Form. Please replace Attachment A of existing Permit No. WQ0031506, issued July 9, 2013, with the corrected Attachment A, attached herewith. We are also enclosing a corrected PPI 001 NDMR rhporting form. If you need additional information concerning this permit correction, please contact David Goodrich at (919) 807-6352 or at david.goodrich@ncdenr.gov. Sincerely, r� oromTlt as A. Reeder Enclosures (2) cc: Orange County Health Department Raleigh Regional Office, Water Quality Regional Operations Section Permit File WQ0031506 Notebook File WQ0031506 AQUIFER PROTECTION SECTION 1636 Mail Service Center, Raleigh, North Carolina 27699-4636 Location: 512 N. Salisbury St., Raleigh, North Carolina 27604 Phone: 919M7-6464 k FAX: 949-807-6496 Internet www.ncwateMuality.org An Equal Opportunity 1 Affrmat ve Action Employer ATTACHMENT A - LIMITATIONS AND MONITORING REQUIREMENTS Permit Number: WQ0031506 Version: 1.6 PPI 001 - Reclaimed Water Generation System Effluent EFFLUENT CHARACTERISTICS EFFLUENT LIMITS MONI'T'ORING REQUIREMENTS' PCS Code Parameter Description Units of Measure Average3 Monthly Geometric Mean minimumaximum Monthly Dailii7 Measurement Frequency Sample Type WQO1 Flow, Reclaimed Water Distributed Gal Continuous Recorder 00076 Turbidity, HCH Turbidimeter NTU 0 Continuous Recorder 80082 BOH Carbonaceous 05 Day, 20C mg/l 10 15 2 X week Composite 00530 Solids, Total Suspended rnjo 5 10 2 X week Composite 31616 Coliform, Fecal MF, M -FC Broth,44.5C #/100 ml 14 25 2 X week Grab 00400 pH su 6.0 9. 2 X week Grab 00610 Nitrogen, Ammonia Total (as N) mg/1 4 6 2 X week Composite 1. Effluent sampling location for all parameters except turbidity and fecal coliform shall be sampled at the effluent sampling point associated with NPDES permit NC0025241. Sampling for turbidity and fecal coliform shall be conducted at the point of entry where the turbidity meter is located. 2. Sampling frequencies are set to be consistent with NPDES permit NCO025241. Sampling results associated with the NPDES permit requirements may be used for reporting requirements for this permit as long as the sampling Iocations remain the same in both permits. 3. The reported value for WQO1 shall be a monthly total. PPI 002 - Bulk Fill Station EFFLUENT CHARACTERISTICS EFFLUENT LIMITS MONITORING REQUIREMENTS PCs Code Parameter Description Units of Measure Monthly Total Monthly Geometric Mean Daily Minimum Daily Maximum Measurement Sample Frequency Type WQ01 Flow, Reclaimed Water Distributed Gal A j. ', See Footnote #1 Recorder I The total flow for the year and estimated monthly flow are to be included in the month of January report of the following year, cited under Condition 1V.& of the Permit. Monthly flows may be estimated based on water meter readings and annual flow totals. ATTACHMENT A - LD41TATIONS AND MONITORING REQUIREMENTS Permit Number: WQ0031506 Version: 1.6 PPI 003 — Cooling Towers at UNC Chiller Plants: Cooling Tower Makeup EFFLUENT CHARACTERISTICS EFFLUENT LIMI'T'S MONITORING REQUIREMENTS PCS Parameter Bescri* tion Units of Monthly Geometric Daily Code pMonthly Total Daily Measurement Sample Measure Mean Minimum Maximum Frequency Type Flow, Reclaimed Water WQ01 Gal Distributed See Footnote #1 Recorder *Estimated average flows distributed to each chiller plant are: Tomkins Chiller Plant =116,000 GPD South Chiller Plant = 368,000 GPD East Chiller Plant - 90,000 GPD LNC Hospitals Chiller Plant = 188,000 GPD 'North Chiller Plant = 252,000 GPD Cobb {Northeast} Chiller Plant = 194,000 GPD 1 The total flow for the year and estimated monthly flow are be included in the month of January report of the following year, cited under Condition IV.S. ofthe Permit. Monthly flows may be estimated based on water meter readings and annual flow totals. PPI 004 — irrigation and toilet flushing at UNC Chapel Hill: Uses listed in Permit WQ0034219 EFFLUENT CHARACTERISTICS EFFLUENT LIMITS MONITORING REQUIREMENTS PCS Parameter Description Units of Monthly Total Monthly Geometric Daily Daily Measurement Sample Code Measure Mean Minimum Maximum Frequency Type Flow, Reclaimed Water WQ01 Distributed Gal See Footnote #1 Recorder 1 The total flow for the year and estimated monthly flow are to be included in the month of January report of the following year, cited under Condition IV -8. of the Permit. Monthly flows may be estimated based on water meter readings and annual flow totals. PPI 005 — St. Thomas More Catholic Community: Athletic Field Irrigation and toilet flushing EFFLUENT CHARACTERISTICS EFFLUENT LIMITS MONITORING REQUIREMENTS PCS Code Parameter Description Units of Measure Monthly Total Monthly Geometric Daily Daily Mean Minimum Maximum Measurement Frequency Sample Type WQ01 Flow, Reclaimed Water D istributed Gal See Footnote #1 Recorder The total flow for the year and estimated monthly flow are to be included in the month of January report of the following year, cited under Condition IV.8. of the Permit. Monthly flows may be estimated based on water meter readings and annual flow totals. FORM SMR 03-12 NON -DISCHARGE MO' 7R1NG REPORT (NDMR) Page_ of Permit No.: WQ0031506 Facility Name: Mason Farm WWTP County: Orange Month: Year: PPI: 001 Flow Measuring Point: ❑ Influent ❑ Effluent ❑ No flow generated Parameter Monitoring Point: ❑ Influent 0 Effluent ❑ Groundwater Lowering ❑ Surface Water Parameter Code — 0 80082 31616 00610 00400 00530 00076 c i� p m L a E m > ¢ .� O �� cJ V)n 0 � O D a o m a p G m m R U _ �a e ami = u a V E o E E < v r �' a a o d s to � Z, is r 24 -hr hrs mg/L #1100 mL 1 mg1L Su mg1L NTU 1 3 4 6 _. 7- 8 10 11 121 -- 13 - 14 1517 - 16 18 19 20 21 22 23 24 25 26 27 28 29 30 31 Average: _ Daily Maximum: -- --- Daily Minimum: _ Y --- Sampling Type: Composite Grab Gcmposite I Grab CumposAa Recorder Monthly Avg. Limit: 10 14 4 5 Daily Limit: 15 25 5 --10 10 Sample Frequency: 2 x Week 2 x Weep Weakly 2 x Week 2 x Vveek _ Continuous