HomeMy WebLinkAboutWQ0029114_Final Permit_20051003�pF WATF9p MichaelF. Easley, Governor
�d G William G. Ross Jr., Secretary
North Carolina Department of Environment and Natural Resources
C Alan W. Klimek, P.E. Director
Division of Water Quality
October 3, 2005
Robert K. McKeithan Jr., President
Oceanic West Development Group
5263 Airport Road
Southport, NC 28461
Subject: Permit No. WQ0029114
Oceanic West Condominiums
Wastewater Treatment and
Reclaimed Water Utilization System
Brunswick County
Dear Mr. McKeithan:
In accordance with your permit application received July 21, 2005, and subsequent additional
information received August 25, 2005, we are forwarding herewith Permit Number WQ0029114, dated
October 3, 2005, to Oceanic West Development Group for the construction and operation of the subject
wastewater treatment and reclaimed water utilization system.
This permit shall be effective from the date of issuance until September 30, 2010, and shall be
subject to the conditions and limitations as specified therein. Please pay particular attention to the
monitoring requirements in this permit. Failure to establish an adequate system for collecting and
maintaining the required operational information will result in future compliance problems.
If any parts, requirements, or limitations contained in this permit are unacceptable, you have the
right to request an adjudicatory hearing upon written request within thirty (30) days following receipt of
this permit. This request must be in the form of a written petition, conforming to Chapter 150B of the
North Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service
Center, Raleigh, NC 27699-6714. Unless such demands are made this permit shall be final and binding.
One set of approved plans and specifications is being forwarded to you. If you need additional
information concerning this matter, please contact Michelle McKay at fP19) 715-6187.
Sincerely
elan W. Klimek, E.
cc: Brunswick County Health Department
Wilmington Regional Office, Aquifer Protection Section
Doug Haggett, PE
Technical Assistance and Certification Unit
Aquifer Protection Central Files
J�ide�
Nam` hCarolina
,�aiur,fa0A
Aquifer Protection Section 1636 Mail Service Center Raleigh, NC 27699-1636 Phone (919) 733-3221 Customer Service
Internet-- httpalh2o.enr.state-nc.us 2728 Capital Boulevard Raleigh, NC 27604 Fax (919) 715-0588 1-977-623-6748
Fax (919)715-6049
An Equal Opportunity/Affirmative Action Employer— 50°!o Recycledli0% Post Consumer Paper
NORTH CAROLINA
ENVIRONMENTAL MANAGEMENT COMMISSION
DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES
RALEIGH
WASTEWATER TREATMENT AND RECLAIMED WATER UTILIZATION PERMIT
In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as
amended, and other applicable Laws, Rules, and Regulations
PERMISSION IS HEREBY GRANTED TO
Oceanic 'West Development Group, Inc.
Brunswick County
FOR THE
construction and operation of a 5,400 GPD wastewater treatment and reclaimed water utilization system
consisting of a 5,400 gallon primary septic tank, a 3,000 gallon aerated equalization basin, a 6,000 gallon
per day dual train recirculating media filter (EnviroFilter), 5,400 gallon per day dual train denitrification
unit (Aquamend), a 1,269 turbidity wet well with sensor and pumps, tablet chlorination unit, a 500 gallon
chlorine contact tank, five day upset storage consisting of two (2) 20,000 gallon storage tanks, a 30,000
gallon dose tank and 29,760 square feet of drip irrigation area to serve Oceanic West Condominiums with
no discharge of wastes to the surface waters, pursuant to the application received July 21, 2005 and
subsequent additional information received by the Division, and in conformity with the project plan,
specifications, and other supporting data subsequently filed and approved by the Department of
Environment and Natural Resources and considered a part of this permit.
This permit shall be effective from the date of issuance until September 30, 2010, and shall be
subject to the following specified conditions and limitations:
I. PERFORMANCE STANDARDS
1. Upon completion of construction and prior to operation of this permitted facility, a certification
must be received froma professional engineer certifying that the permitted facility has been
installed in accordance with this permit, the approved plans and specifications, and other
supporting materials. If this project is to be completed in phases and partially certified you shall
retain the responsibility to track further construction approved under the same ermit and shall
provide a final certificate of completion once the entire project has been completed. Mail the
Certification to the Land Application Unit, 1636 Mail Service Center, Raleigh, NC 27699-1636.
2. The Wilmington Regional Office, telephone number (910) 395-3900, shall be notified at least
forty-eight (48) hours in advance of operation of the installed facilities so that an in -place
inspection can be made. Such notification to the regional supervisor shall be trade during the
normal office hours from 8:00 a.m. until 5:00 p.m. on Monday through Friday, excluding State
Holidays.
The reclaimed water utilization facilities shall be effectively maintained and operated at all times
so that there is no discharge to the surface waters, nor any contamination of ground waters, which
will render them unsatisfactory for normal use. In the event that the facilities fail to perform
satisfactorily, including the creation of nuisance conditions or failure of the irrigation area to
adequately assimilate the wastewater, the Permittee shall take immediate corrective actions
including those actions that may be required by the Division of Water Quality (Division), such as
the construction of additional or replacement wastewater treatment and disposal facilities.
4. The issuance of this permit shall not relieve the Permittee of the responsibility for damages to
surface water or ground water resulting from the operation of this facility.
5. The residuals generated from these treatment facilities must be disposed in accordance with
General Statute 143-215.1 and in a manner approved by the Division.
6. Diversion or bypassing of the untreated wastewater from the treatment facilities is prohibited.
7. The following buffers shall be maintained:
a. 100 feet between wetted areas and water supply wells,
b. 100 feet between wetted areas and waters classified as SA,
c. 25 feet between wetted areas and surface waters not classified as SA,
d. 100 feet between wastewater treatment units and wells,
e. 50 feet between reclaimed water storage/irrigation ponds and property lines, and
f. 50 feet between wastewater treatment units and property lines.
Public access to the irrigation sites shall be controlled during active site use_ Such controls may
include the posting of signs showing the activities being conducted at each site. A sign shall be
posted in plain sight in the clubhouse showing these activities.
9. A leakage test shall be performed on the septic tank and dosing tank to insure that any exfiltration
occurs at a rate, which does not exceed twenty (20) gallons per twenty-four (24) hours per 1,000
gallons of tank capacity. The engineers certification will serve as proof of compliance with this
condition.
10. The disposal system shall be connected to a rain or moisture sensor that shall indicate when
wastewater application is not appropriate in accordance with Condition II(4) of this permit.
11. The following shall be requirements for the reclaimed water distribution, storage, and utilization
facilities:
a. All reclaimed water valves, storage facilities, and outlets shall be tagged or labeled to warn
the public or employees that the water is not intended for drinking. Where appropriate, such
warning shall inform the public or employees to avoid contact with the water.
b. All reclaimed water piping, valves, outlets, and other appurtenances shall be color -coded,
taped, or otherwise marked to identify the source of the water as being reclaimed water.
i. All reclaimed water piping and appurtenances shall be either colored purple (i.e., Pantone
522) and embossed or integrally stamped or marked "CAUTION: RECLAIMED
WATER — DO NOT DRINK" or be installed with a purple (i.e., Pantone 522)
identification tape or polyethylene vinyl wrap. The warning shall be stamped on opposite
sides of the pipe and repeated every three feet or less.
ii. Identification tape shall be at least three inches wide and have white or black lettering on
purple (i.e., Pantone 522) field stating "CAUTION: RECLARVIED WATER — DO NOT
DRINK." Identification tape shall be installed on top of reclaimed water pipelines,
fastened at least every 10 feet to each pipe length and run continuously the entire length
of the pipe.
c. All reclaimed water valves and outlets shall be of a type, or secured in a manner, that peri its
operation by authorized personnel only.
d. Above -ground hose bibs (i.e., spigots or other hand -operated connections) shall not be
present. Hose bibs shall be located in locked below -grade vaults that shall be clearly labeled
as being of non -potable quality. As an alternative to the use of locked below -grade vaults
with standard hose bibs services, hose bibs, which can only be operated by a special tool or
connected to a special hose connection, may be placed in non -lockable underground services
boxes clearly labeled as non -potable water.
II. OPERATION AND MAINTENANCE REQUIREMENTS
1. The facilities shall be properly maintained and operated at all times.
2. Upon classification of the wastewater treatment and irrigation facilities by the Water Pollution
Control System Operators Certification Commission (WPCSOCC), the Permittee shall designate
and employ a certified operator to be in responsible charge (ORC) and one or more certified
operator(s) to be back-up ORC(s) of the facilities in accordance with 15A NCAC 8G .0201. Tlie
ORC shall visit the facilities in accordance with 15A NCAC 8G .0204 or as specified in this
permit and shall comply with all other conditions specified in these rules.
3. A suitable, year-round vegetative cover shall be maintained on the irrigation areas.
4. Irrigation shall not be performed during inclement weather or when the ground is in a condition
that will cause runoff.
5. Adequate measures shall be taken to prevent wastewater runoff from the irrigation field.
6. The facilities shall be effectively maintained and operated as a non -discharge system to prevent
the discharge of any wastewater resulting from the operation of this facility.
7. The application rate shall not exceed a cumulative Ioading of 110 inches over any twelve (12)
month period at an instantaneous application rate not to exceed 0.075 inches per hour for zones 3,
5 and 8.
8. The application rate shall not exceed a cumulative loading of 104 inches over any twelve (12)
month period at an instantaneous application rate not to exceed 0.071 inches per hour for zones 1,
2, 4, 6 and 7.
9. An automatically activated standby power source shall be on site and operational at all times. If a
generator is employed as an alternate power supply, it shall be tested weekly by interrupting the
primary power source.
10. No type of wastewater other than that from Oceanic West Condominiums shall be irrigated onto
the irrigation area.
11. All wastewater shall be routed to the five-day holding pond should the limit for fecal coliform
(daily maximum concentration of 25 per 100 ml) or turbidity (instantaneous maximum of 10
NTU) be exceeded, until such time that the problems associated with the treatment capability of
the wastewater treatment plant have been corrected. The wastewater in the five-day holding pond
shall be pumped back to the treatment plant for re -treatment or treated in the five-day pond prior
to discharge to the storage pond.
12. The chlorine tablets used in the disinfection facility shall be of the kind and type specified in the
Division approved plans and specifications.
III. MONITORING AND REPORTING REQUIREMENTS
1. Any monitoring (including groundwater, surface water, soil or plant tissue analyses) deemed
necessary by the Division to insure surface and ground water protection will be established and
an acceptable sampling reporting schedule shall be followed.
2. Influent flow shall be continuously monitored and daily average flow values shall be reported on
Form NDMR. Flow may be estimated from water use records provided water use is metered.
Daily average values shall be calculated by dividing monthly flow volume by the number of days
in the month.
3. As an indicator of proper operation and maintenance, the facility shall produce an effluent in
compliance with the following limitations:
Parameter
Monthly Average"
Daily (Instantaneous) Maximums
Flow
5,400 GPD
BOD5 (5-day, 20'Q
10 mg/1
15 mg/l
NH3 as N
4 mg/l
6 mg/i
TSS
5 mg/l
10 mg/1
Fecal Coliform
14 per 100 ml b
25 per 100 ml
Turbidity
10 NTU
NO3
2.5 mg/1
The effluent pH small not be less than 6.0 standard units nor greater than 9.0 standard units.
a Monthly averages for all but fecal coliform shall be the arithmetic mean of all samples
collected during the reporting period.
b
Monthly average for fecal coliform shall be the geometric mean of all samples collected
during the reporting period.
Daily maximum shall be the maximum value of all samples collected during the reporting
period.
4
The Permittee shall monitor the effluent from the subject facilities at the point prior to irrigation
for the following parameters:
Parameter
Sampling Point
Sampling Frequency
Type of Sample
Flow
Influent or Effluent
Continuous
Recording
Turbidity
Effluent
Continuous
Recording
BOD5 (5-day, 20°C)
Effluent
2/Month
Composite
NH3 as N
Effluent
*2/Month
Composite
TSS
Effluent
*2/Month
Composite
Fecal Coliform
Effluent
*2/Month
Grab
Settleable Matter
Effluent
Daily
Grab
Residual Chlorine
Effluent
Daily
Grab
NO3
Effluent
*2/Month
Grab
TDS
Effluent
*`Triannually
Grab
TOC
Effluent
Triannually
Grab
Chloride
Effluent
**Triannually
Grab
pH
Effluent
*'Triannually
Grab
* 2/Month sampling frequency only during the months of April through October. During the
remainder of the year, these parameters shall be monitored monthly.
** Triannually sampling shall be conducted during March, July, and November.
4. The Permittee shall maintain adequate records tracking the amount of wastewater disposed.
These records shall include, but are not necessarily limited to the following information:
a. Date and time of irrigation,
b. Volume of wastewater irrigated,
c. Zone irrigated,
d. Length of time zone is irrigated,
e. Continuous weekly, monthly, and year-to-date hydraulic (inchesiacre) loadings for each zone,
f. Weather conditions, and
g. Maintenance of cover crops.
Three (3) copies of all monitoring data [as specified in Conditions III(2) and III(3)] on Form
NDMR-1 and three (3) copies of all operation and disposal records [as specified in Conditions
III(4)] on Form NDAR-1 shall be submitted monthly on or before the last day of the following
month. All information shall be submitted to the following address:
NC Division of Water Quality
Information Processing Unit
1617 Mail Service Center
Raleigh, North Carolina 27699-1617
6. A record shall be maintained of all residuals removed from this facility. This record shall include
the name of the hauler, permit authorizing the disposal or a letter from a municipality agreeing to
accept the residuals, date the residuals were hauled, and volume of residuals removed.
7. A maintenance log shall be maintained at this facility including but not limited to the following
items:
a. Daily sampling results of dissolved oxygen in the aeration basin and at the clarifier weir.
b. Visual observations of the plant and plant site.
c. Record of preventative maintenance (changing of filters, adjusting belt tensions, alarin
testing, diffuser inspections and cleanings, etc.).
d. Date of calibration of flow measurement device.
e. Date and results of power interruption testing on alternate power supply.
8. Noncompliance Notification:
The Permittee shall report by telephone to the Wilmington Regional Office, telephone number
(910) 395-3900, as soon as possible, but in no case more than 24 hours or on the next working
day following the occurrence or first knowledge of the occurrence of any of the following:
a. Any occurrence at the wastewater treatment facility which results in the treatment of
significant amounts of wastes which are abnormal in quantity or characteristic, such as the
dumping of the contents of a sludge digester; the known passage of a slug of hazardous
substance through the facility; or any other unusual circumstances.
b. Any process unit failure, due to known or unknown reasons, that render the facility incapable
of adequate wastewater treatment such as mechanical or electrical failures of pumps, aerators,
compressors, etc.
c. Any failure of a pumping station, sewer line, or treatment facility resulting in a by-pass
directly to receiving waters without treatment of all or any portion of the influent to such
station or facility.
d. Any time that self -monitoring information indicates that the facility has gone out of
compliance with its permit limitations.
Occurrences outside normal business hours may also be reported to the Division's
Emergency Response personnel at telephone number (800) 662-7956, (800) 858-0368, or
(919) 733-3300. Persons reporting such occurrences by telephone shall also file a written
report in letter form within five (5) days following first knowledge of the occurrence. This
report must outline the actions taken or proposed to be taken to ensure that the problem does
not recur.
IV. GROUNDWATER REQUIREMENTS
1. Vertical Separation Requirements:
Waste shall not be applied or discharged onto or below the land surface when the vertical separation
between the waste and the seasonal high water table is less than one (1) foot.
2. Applicable Boundaries:
The COMPLIANCE BOUNDARY and REVIEW BOUNDARY for the waste disposal area(s) is
specified by regulations in 15A NCAC 2H, Waste Not Discharged to Surface Waters, specifically
.0219(k)(1)(C)(i)(III). The Compliance Boundary and the Review Boundary for groundwater shall be
established at the property boundary. An exceedance of Groundwater Quality Standards at or beyond the
Compliance Boundary is subject to remediation action according to 15A NCAC 2L .0106(d)(2).
V. INSPECTIONS
1. Adequate inspection, maintenance, and cleaning shall be provided by the Permittee to insure
proper operation of the subject facilities.
2. The Permittee or his designee shall inspect the wastewater treatment and disposal facilities to
prevent malfunctions and deterioration, operator errors and discharges which may cause or lead to
the release of wastes to the environment, a threat to human health, or a nuisance. The Permittee
shall keep an inspection log or summary including at Ieast the date and time of inspection,
observations made, and any maintenance, repairs, or corrective actions taken by the Permittee.
This log of inspections shall be maintained by the Permittee for a period of three years from the
date of the inspection and shall be made available upon request to the Division or other permitting
authority.
3. Any duly authorized officer, employee, or representative of the Division may, upon presentation
of credentials, enter and inspect any property, premises or place on or related to the disposal site
or facility at any reasonable time for the purpose of determining compliance with this permit;
may inspect or copy any records that must be maintained under the terms and conditions of this
permit, and may obtain samples of groundwater, surface water, or leachate.
VI. GENERAL CONDITIONS
1. This permit shall become voidable unless the facilities are constructed in accordance with the
conditions of this permit, the approved plans and specifications, and other supporting data.
2. This permit is effective only with respect to the nature and volume of wastes described in the
application and other supporting data.
3. The Operational Agreement between the Permittee and the Environmental Management
Commission is . incorporated herein by reference and shall be a condition of this permit.
Noncompliance with the terms of the Operational Agreement shall subject the Permittee to all
sanctions provided by North Carolina General Statutes § 143-215.6A to § 143-215.6C for violation
of or failure to act in accordance with the terms and conditions of this permit.
4. This permit is not transferable. In the event there is a desire for the facilities to change
ownership, or there is a name change of the Permittee, a formal permit request must be submitted
to the Division accompanied by an application fee, documentation from the parties involved, and
other supporting materials as may be appropriate. The approval of this request will be considered
on its merits and may or may not be approved.
5. Failure to abide by the conditions and limitations contained in this permit may subject the
Permittee to an enforcement action by the Division in accordance with North Carolina General
Statute 143-215.6A to 143-215.6C.
6. The issuance of this permit does not exempt the Permittee from complying with any and all
statutes, rules, regulations, or ordinances which may be imposed by other government agencies
(local, state, and federal) which have jurisdiction, including but not limited to applicable river
buffer rules in 15A NCAC 213.0200, erosion and sedimentation control requirements in 15A
NCAC Chapter 4 and under the Division's General Permit NCG010000, and any requirements
pertaining to wetlands under 15A NCAC 2B .0200 and 211.0500.
7. The Permittee shall retain a set of approved plans and specifications for the subject facility for the
life of the project.
S. The Permittee shall pay the annual administering and compliance fee within thirty days of being
billed by the Division. Failure to pay the fee accordingly may cause the Division to initiate action
to revoke this permit as specified by .15 NCAC 2H .0205 (c)(4).
9. The Permittee, at least six (6) months prior to the expiration of this permit, shall request its
extension. Upon receipt of the request, the Commission will review the adequacy of the facilities
described therein, and if warranted, will extend the permit for such period of time and under such
conditions and Iimitations as it may deem appropriate.
Permit issued this the 3`d day of October 2005
NORTH C ILINA ENV ONMENTAL MANAGEMENT COMMISSION
a
elan W. Klimek, P.E., Director
Division of Water Quality
By Authority of the Environmental Management Commission
Permit Number WQ0029114
Permit No. WQ0029114
October 3, 2005
ENGINEER'S CERTIFICATION
Partial Final
1, , as a duly registered Professional Engineer in the State
of North Carolina, having been authorized to observe (periodically, weekly, full time) the construction of
the project,
Project Name
Location and County
for the Pernuttee hereby state that, to the best of my abilities, due care and diligence was used in the
observation of the construction such that the construction was observed to be built within substantial
compliance and intent of this permit, the approved plans and specifications, and other supporting
materials.
Signature Registration No.
Date
a
ON
.tea �.� .• i � ,�„�"'; � � �;, �
...,' 7-
•Att
�^A�,fil
a
Long
Beach
0
F'
Oceanic West Condominiums
WQ0029114
500 250 0 500 Feet
N
W+E
S
' VATER POLLUTION; COtiTROL SYSTEM OP-=LATORS
CERTIFICAT 10N CO-NL'NIISSI01
CLASSIFICATION
RATING SHEET FOR WATER POLLUTION CONTROL SYSTEMS
FACILITY INTORNLATION
64CL2NAME OF FACILITY: L �� v
MAILING ADDRESS: i `c) . e, f+ _ ;� _ � tit;! ; f' z
COUNTY:-'rvas� _ [�
CONTACT PERSON:: °" s r� �r r 1, Zia; '<TEL.EPHONE: (` F �� `
PERMIT NO: ��.A i `-� Check One: NC WQ HEALTH DP
ORC: V d- C,,S5 i s 4c 4 TELEPHONE: (�}
J
RATING INFORMATION: (Before completing this section, please refer to pages 2-4)
PERMITTED FLOW: ,' O() C1 J I� BNR? YES NO
CHECK CLASSIFICATION: WASTEWATER: 1 2 3 V/ 4
COLLECTION: 1_ Z 2 3 4
MV.1
LRRIGATION -�LL--SUBSURFACE --- -- -LAND _APPLICATION- _--��
PHYSICALICHEMICAL GRADE I GRADE II
RATED BY: REGION: r iOfdl -�A- DATE: I S
REGIONAL OFFICE TELEPHONE NUMBER: �E) V -72) S EXT:
Classification of Biological Water Pollution Control Treatment Systems:
Grade I Biological WPCS
- Septic tank/sand filter systems
- Biological lagoon systems
- Constructed wetlands and associated appurtenances
Grade II Biological WPCS
- Systems that utilize an activated sludge or fixed growth process with a permitted flow
less than or equal to 0.5 million gallons per day (mad)
Grade III Biological WPCS
- Systems that utilize an activated sludge or fixed growth process with a permitted flow
of greater than 0.5 through 2.5 million gallons per day (mad)
- Grade II systems that are required to achieve biological nutrient reduction
Grade IV Biological WPCS
-- Systems that utilizing an activated sludge or fixed growth process with a permitted flow
of greater than 2.5 million gallons per day (mgd)
- Grade III systems that are required to achieve biological nutrient reduction
* Biological Nutrient Reduction -
The reduction of total nitrogen or total phosphorous by an activated sludge or fixed growth
process as required by the facilities permit.
Classification of Collection Water Pollution Control Systems:
(whichever provides lowest grade)
Sarre grade as biological water pollution control system. Grade of system: i
Based on population served:
!.% 1,500 or Less = Grade I
1,501 to 15,000 = Grade U
15,001 to 50,000 = Grade III
50,001 or more = Grade IV
Classification of av Irrigation Water Pollution Control Systems:
Systems which utilize sp� urination for the reuse or disposal of wastewwater.
These systems include: septic tanks, sand filter, oil/water separators, lagoons,
storage basins, screening, sedimentation. Systems other than those listed above
shall be subject to additional classification.
-------------------------------------------------------------------------------------------------------------------
Classification of Land Application of Residuals Systems:
Systems permitted and dedicated for land application of residuals that are produced by -a
water pollution control system or contaminated soils.
Classification of Phvsical/Cbemical Water Pollution Control Treatment Systems:
Grade 1 Physical/Chemical: Any water pollution control'systern that utilizes a primarily
physical process to treat wastewater. This classification includes groundwater
remediation systems. **
Grade 11 Physical/Chemical: Any water pollution control system that utilizes a primarily
chemical process to treat wastewater. This classification includes reverse osmosis, _
electrodialysis, and ultraf"iltration systems. **
"Any water pollution control system that utilizes a phyicaUchemical process to enhance an
activated sludge orfixed growth process. shall n t_be sub 2Ct to additiona classi cation
�— ---- Classification-of-Subsurface=W.ater�PollutiorfContrafSystems.-------_ --_-
Systems which utilize the'soil for subsurface treatment and disposal of wastewater .r
andlor are required to have a certified operator under 15A NCAC 18A.1961. ***
*** Any subsurface system that has as part of its treatment process a water pollution control
systems that may be classified under Rules .0302 through .0307 of this section shall be
subject to addional classification.