Loading...
HomeMy WebLinkAboutNCG550123_Compliance Evaluation Inspection_20180926 I Ia.` 116 , :...fee,;4 y *... (6 r r4 , Cxr ,,,,It: i.,„.4, ,,./p If ,,t ., X N'Q 1T H CAP 011 NA ROY COOPER. Erwirardrrreretcrt Quality 06,pe,rrt.rr MICHAEL S.REGAN secretary LINDA CULPEPP'ER rrrrennrn D'rerz RECEI�IEDIDE'��Dw September 26, 2018OCA 1 2418 Mr.Robert Mays Water R g Section 5622 Brisbane Dr. permitting Chapel Hill,NC 27514 Subject: Compliance Evaluation Inspection Single Family Wastewater Treatment System Permit No.NCG550123 Orange County Dear Permittee: On September 24, 2018, Jeremiah Dow from the Raleigh Regional Office visited your single-family - residence(SFR)wastewater treatment system to evaluate compliance with the above permit to discharge wastewater. Mr.Mays' assistance during the inspection was greatly appreciated. The checked boxes below show what conditions were noted at your facility: n In compliance: You are reminded to regularly maintain the chlorine disinfection and dechlorination systems,have the effluent sampled once a year, and have the septic tank pumped out every 3 to 5 years. Your good record of operation and meeting the permit requirements is highly commended. n Your home is improperly plumbed: Some of the wastewater discharges are going directly to the environment without first passing through the treatment system. This must be corrected immediately. Please submit a schedule to this office within 20 days of receipt of this letter that states your plan for correcting this deficiency. The work is to be completed within the next 3 months. - ❑ Disinfectio 1:: Your system is lacking disinfection, either chlorine tablets or a UV light system. New rules put into place on August 1, 2007 require all SFR systems to have a means of disinfection(and dechlorination when chlorine tablets are used to disinfect, if the system was installed since that date). Since your system had no disinfection,the installation is to include a chlorine tablet dispenser, a contact chamber capable of providing a minimum 30 minute contact M r-tri _, North Carolina Department of Environmental Quality I Division of Water Resources Quality I Raleigh Regional Office 1628 Mail Service Center I Raleigh,North Carolina 27699-1628 919.791.4200 time, and another tablet dispenser that will hold dechlorination tablets. Please submit a schedule to this office within 20 calendar days of receipt of this letter that states your plan for correcting this deficiency. ❑ Treatment tablets missing or are wrong kind: You are responsible for always having chlorine tablets and dechlorination tablets (if a required part of your system) in place. They must be the kind for wastewater treatment and not for swimming pools. n Dechlorination: Your system was installed after August 1, 2007, so must have a means of dechlorination located downstream of the chlorinator and its contact chamber. See Disinfection paragraph above. Please submit a schedule to this office within 20 calendar days of receipt of this letter stating your plan for correcting this deficiency. ❑Pumping the septic tank: The septic tank should be pumped out every 3 to 5 years. A pumping company can check the status periodically and determine when pumping is required. El Failure to analyze the effluent: The effluent that is discharged from your system must be analyzed once each year. See Part I(A)of your permit about his requirement. Please make arrangements for sampling to be carried out within the next 3 months, and submit results to this office within 3 weeks after the sampling has been done. n Locations of treatment units are unknown: Determine this and report to this office within 30 days of receipt of this letter with a sketch or map. n Other: If you have questions or comments about this inspection or the requirements to take corrective action, please contact Jeremiah Dow at 919-791-4200. Licensed plumbers should be used to make plumbing, changes within your home. Contractors for installing disinfection or other equipment may be found in the Yellow Pages under Environmental Consultants. Sincerely, 51e'///: 22/ S.Daniel Smith, Supervisor Water Quality Regional Supervisor Raleigh Regional Office - Attachments: Inspection Reports cc: RRO/SWP Files Charles Weaver,NPDES Permitting Unit �, North CarolinaDepartmentof Environmental Quality I Division of Water Resources Quality I Raleigh Regional Office 1628 Mail Service Centerl Raleigh,North Carolina 27699-1628 919 791.4200 / United States Environmental Protection Agency Form Approved. EPA Washington,D.0 20460 OMB No 2040-0057 Water Compliance Inspection Report Approval expires 8-31-98 Section A National Data System Coding(i e,PCS) Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type 1 L N I 2 I5 1 -3 I NCG550123 11 1 121 18/09/24 117 18 Li, 19 I I 201 1 211 I I I I 1 1 I 1 1 1 1 1 I I I 1 I 1 1 I I I 1 I I I I 1 H 1 1 I I I I I I I I I 166 Inspection Work Days Facility Self-Monitoring Evaluation Rating B1 QA ---------------Reserved l 671 I 701 1 711 I 72 I-1 1 , 1 731 1 174 75i I I I 1 1 1 180 Section B:Facility Data Name and Location of Facility Inspected(For Industrial Users discharging to POTW,also include Entry Time/Date Permit Effective Date POTW name and NPDES permit Number) 10 23AM 18/09/24 13/08/01 5622 Brisbane Drive 5622 Brisbane Dr Exit Time/Date Permit Expiration Date Chapel Hill NC 275149689 • 10.35AM 18/09/24 18/07/31 Name(s)of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) Other Facility Data /// Name,Address of Responsible Official/Title/Phone and Fax Number Contacted Robert G Mays,5622 Brisbane Dr Chapel Hill NC 275149689/// No Section C Areas Evaluated During Inspection(Check only those areas evaluated) -n Operations&Maintenance ® Self-Monitoring Program ® Facility Site Review ® Effluent/Receiving Waters Section D Summary of Finding/Comments(Attach additional sheets of narrative and checklists as necessary) (See attachment summary) • Name(s)and Signature(s)of Inspector(ss)) �` Agency/Office/Phone and Fax Numbers Date Jeremiah J Dow v ( L' Division of Water Quality//919-791-4248i 06/F Signat re of Manageent Q A Fjeviewer" Agency/Office/Phone and Fax Numbers Date tf .&------r /9C- , 22;f7e//://e/d/(' �, .2-7 /,,7 EPA Form 3564(Rev 9-94)Previous editions are obsolete Page# 1 a st NPDES yr/mo/day Inspection Type 1 31 NCG550123 111 121 18/09/24 117 18 Ld Section D:Summary of Finding/Comments(Attach additional sheets of narrative and checklists as necessary) 1 • - Page# 2 / Permit. NCG550123 Owner-Facility: 5622 Brisbane Drive Inspection Date: 09/24/2018 Inspection Type: Compliance Evaluation Operations & Maintenance Yes No NA NE Is the plant generally clean with acceptable housekeeping? ® 0 0 0 • Does the facility analyze process control parameters,for ex:MLSS, MCRT,Settleable ❑ 0 ® 0 Solids, pH, DO,Sludge Judge, and other that are applicable? Comment: Effluent Pipe Yes No NA NE Is right of way to the outfall properly maintained? ® 0 0 0 Are the receiving water free of foam other than trace amounts and other debris'? ® 0 0 0 If effluent (diffuser pipes are required) are they operating properly? ❑ 0 ® 0 Comment: Septic Tank Yes No NA NE (If pumps are used)Is an audible and visual alarm operational? 0 ❑ ril 0 Is septic tank pumped on a schedule'? ..- 0 0 ❑ Are pumps or syphons operating properly? 0 0 ® 0 Are high and low water alarms operating properly'? ❑ 0 ® 0 Comment: Last pumped in November, 2017. Disinfection-Tablet Yes No NA NE _Are tablet chlorinators operational? - -- - - - - - -- CI -0 ❑- Are the tablets the proper size and type? RE 0 0 0 Number of tubes in use'? 2 Is the level of chlorine residual acceptable? 0 0 IN 0 Is the contact chamber free of growth, or sludge buildup? x71 ❑ 0 ❑ Is there chlorine residual prior to de-chlorination? ❑ 0 ® 0 Comment: Effluent Sampling Yes No NA NE Is composite sampling flow proportional'? 0 0 7 0 Is sample collected below all treatment units? 0 0 0 Is proper volume collected? 0 ❑ s' ❑ Is the tubing clean? 0 0 , ❑ #Is proper temperature set for sample storage(kept at less than or equal to 6.0 degrees ❑ 0 ; ❑ Celsius)? Page# 3 Permit: NCG550123 Owner-Facility: 5622 Brisbane Drive Inspection Date: 09/24/2018 Inspection Type: Compliance Evaluation Effluent Sampling Yes No NA NE Is the facility sampling performed as required by the permit(frequency,sampling type 0 ® 0 0 representative)? Comment: Annual sampling has not been completed. Page# 4