Loading...
HomeMy WebLinkAboutWQ0023896_Correction AttC_20140624SCANNED NCDENR North Carolina Department of Environment and Natu Pat McCrory Governor June 24, 2014 MATHEw M. FAJACK - VICE CHANCELLOR OF FINANCE & ADMINISTRATION THE UNIVERSITY OF NORTH CAROLINA AT CHAPEL HILL CB# 1000 - 302A SOUTH BUILDING CHAPEL HILL, NORTH CAROLINA 27599-1000 DATE: 2- � ZD (� John E. Skvada, III Secretary SCANNED DATE: Z-/ ``1 M— Subject: Permit No. WQ0023896 MW-2 Abandonment and Attachment C Correction LJNC-CH Bingham Facility Wastewater Irrigation System Orange County Dear Mr. Fajack: In accordance with a written request received May 6, 2014 from Mary Beth Koza, the Division of Water Resources approves the permanent abandonment of monitoring well MW-2. Accordingly, within 60 days of the date of this letter, monitoring well MW-2 shall be permanently abandoned. Within 30 days of abandonment, a Well Abandonment Record (Form GW-30) listing this permit number and the appropriate monitoring well identification number shall be completed for each well abandoned and ItRw mailed to the Division of Water Resources, Water Quality Permitting Section, 1636 Mail Service Center, Raleigh, NC 27699-1636. A North Carolina Certified Well Contractor shall abandon the monitoring wells according to the North Carolina Well Construction Standards (I5A NCAC 02C .0113) and local county rules. In addition, we are forwarding herewith a corrected Attachment C of Permit No. WQ0023896 issued April 12, 2013. The correction to the Attachment C is the removal of monitoring well MW-2 frorn the sampling schedule. If you need additional information concerning this pen -nit correction, please contact Nathaniel Thornburg at (919) 807-6453 or nathaniel.tliornburg(.@ncdenE_gov. Sincerely, Noma A. Reeder, Director Division of Water Resources Enclosure cc: Orange County Health Department Raleigh Regional Office, Water Quality Regional Operations Section Charles D. Riley, Jr., PE - McKim & Creed Permit File WQ0023896 N411W Notebook File WQ0023896 1636 Wil Service Ceoler, Raleigh, North Carolina 27699-1536 Phone_ 919-807-6454 + Intemet: htip:11pprial ncdenr.arglwebtwg An Equal Opporlurmy l AKrmalive kcfori Employer — h4ade in parl wish recycled paper 31 ATTACHMENT C — GROUNDWATER MONITORING AND LIMITATIONS Monitoring wells: MW-1, MW-3, MW-4, MW-5 and MW-6 Permit Number: WQ0023896 Version:l.3 91 GROUNDWATER CHARACTERISTICS GROUNDWATER STANDARDS MONITORING REQUIREMENTS PCs Code Parameter Description Daily Maximum Frequency Measurement Sample Type Footnotes 00680 Carbon, Total Organic (TOC) mg/L 4 x Year Grab 1,6 00940 Chloride (as CI) 250 mg/L 4 x Year Grab 1 31616 Coliform, Fecal MF #/100mL 4 x Year Grab I 00610 Nitrogen, Ammonia Total (as N) 1.5 mg/L 4 x Year Grab 1 00620 Nitrogen. Nitrate Total (as N) 10 mg/L 4 x Year Grab 1 00400 pl-i 6.5-8.5 su 4 x Year Grab 1,2 00665 Phosphorus, Total (as P) mg/L 4 x Year Grab 1 70300 Solids. Total Dissolved — 180 °C 500 mg/L 4 x Year Grab I NDVOC Volatile Organic Compounds Presence: Yes/No Annually Grab 1, 4, 5 82546 I Water level, distance from measuring point ft 4 x Year Calculated 1, 2, 3 I . 4 x Ycar monitoring shall be conducted in March, June, September & December; Annual monitoring shall be conducted every December. 2. The measurematt of water levels shall be made prior to purging the wells. The depth to water in each well shall be measured from the surveyed point on the top of the casing. The measurement of p1l shall be made after purging and prior to sampling for the remaining parameters. 3. The measuring points (top of well casing) of all monitoring wells shall be surveyed to provide the relative elevation of the measuring point for each monitoring well. The measuring points (top of casing) of all monitoring wells shall be surveyed relative to a common datum. 4. Volatile Organic Compounds (VOC) - In December only, analyze by one of the following methods: a. Standard Method 6230D. PQL at 0.5 µg/L or less h. Standard Method 621 OD, PQL at 0.5 µg/L or less C. IPA Method 8021, Low Concentration, PQL at 0.5 µg/L or less d. EPA Method 8260. Low Concentration, PQL at 0.5 µg/L or less C. Another method with prior approval by the Aquifer Protection Section Chief Any method used must meet the following qualifications: a. A laboratory must be DWQ certified to run any method used. b. The method used must, at a minimum, include all the constituents listed in Table VIII of Standard Method 6230D. C. The method used must provide a PQL of 0.5 µg/L or less that must be supported by laboratory proficiency studies as required by the DWQ Laboratory Certification Unit.; Any constituents detected above the MDL but below the PQL of 0.5 µg/L must be qualified (estimated) and reported. 5. If any volatile organic compounds (VOC) are detected as a result of monitoring as provided in Attachment C, then the Raleigh Regional Office Aquifer Protection Supervisor, telephone number (919) 791-4200. must be contacted immediately for further instructions regarding any additional follow-up analyses required. 6. If TOC concentrations greater than 10 mg/L are detected in any downgradient monitoring well, additional sampling and analysis must be conducted to identify the individual constituents comprising this TOC concentration. If the TOC concentration as measured in the background monitor well exceeds 10 mg/L, this concentration will be taken to represent the naturally occurring TOC concentration. Any exceedances of this naturally occurring TOC concentration in the downgradient wells shall be subject to the additional sampling and analysis as described above. 7. Monitoring wells shall be reported consistent with the nomenclature and location information provided in Figure 1 and this attachment. WQ0023896 Version 1.3 Attachment C Page I of I