HomeMy WebLinkAboutWQ0023261_Final Permit_20091027MCDENR North uarolina Department of Environment and Natural Resources Beverly Eaves Perdue Governor Jeff L. Pearson, Executive Director OnslouT Water and Sewer Authority PO Box 1415 Jacksonville, North Carolina 28-540 Dear Mr, Pearson: Division of Water Quality Coleen H. Sufiins Dee Freeman Director Secretary October 27, 2009 Subject: Permit No. WQ0023261 Swansboro WWTF Wastewater Treatment and Reclaimed Water Utilization System Onslow County In accordance with your permit modification request received October 15, 2009, we are forwarding herewith Permit No. WQ0023261, dated October 27, 2009, to Onslow Water and Sewer Authority for the continued operation of the subject reclaimed water treatment and utilization system. This modification is issued to change the name of the owner of record from the Town of Swansboro to Onslow Water and Sewer Authority. On August 5, 2009, Session Law 2009-406, entitled "An Act to Extend Certain Government Approvals Affecting the Development of Real Property within the State," Nvas enacted by the General Assembly and signed into law. The Act, known as the Permit Extension Act of 2009, extends the expiration date of certain government approvals and permits. Non -discharge permit, WQ0023261, issued by the Division of Water Quality falls within the scope of this Act and is therefore being extended until September 25, 2014. Please note per your permit, a renewal application roust still be submitted six months in advance of the extended expiration date. This modified permit shall be effective from the date of issuance until September 25, 2014, shall void Permit No. WQ0023261 issued September 26, 2006, and shall be subject to the conditions and limitations as specified therein, - Please pay particular attention to the monitoring requirements in this permit. Failure to establish an adequate system for collecting and maintaining the required operational information will result in future compliance problems. AQUIFER PROTEC7101: SE 7 01 1636 Ma jervic-. Gente;. Raletor North ,araiina276994E3; �ocauor:: 272E Caporal BouwMarc, rtaieign worm it a!' una 276N Phone: 915-733-3221 =AX 1: 915'15-0566; FAX 2: 91-715-6M4 customer Service 377-623-674i Internet www.ncwaterquaI&V.om Dnt Nc)?Ch Carolina An E4ua C)Dnonunr , Aihrmov., -cnc mpmve- If any parts, requirements, or limitations contained in this permit are unacceptable to you, you have the right to an adjudicatory hearing upon written request within thirty (30) days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 150B of North Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, N. C. 27699-6714. Unless such demands are made, this permit shall be final and binding. If you need additional information concerning this matter, please contact Chonticha McDaniel at (919) 715-6188 or chonticha.mcdaniel@ncdenr.gov. Sincerely, ,jor Coleen H. Sullins cc: Onslow County Health Department Wilmington Regional Office, Aquifer Protection Section Technical Assistance and Certification Unit Permit File WQ0023261 Notebook File WQ0023261 NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES RALEIGH WASTEWATER TREATMENT AND RECLAIMED WATER UTILIZATION PERMIT In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations PERMISSION IS HEREBY GRANTED TO Onslow Water and Sewer Authority FOR THE continued operation of a 600,000 gpd wastewater treatment and reclaimed water utilization facility, consisting of: Wastewater Treatment Facilities a 123,000 gallon equalization basin, two 22-foot diameter, 12-foot side water depth secondary clarifiers, a dual rotating cloth disk filters with automatic backwash, an influent flowmeter, a headworks structure including a 1.5 mgd mechanical semi -cylindrical screen with screw conveyer, a 1.5 mgd vortex grit removal chamber system, and manual bar screen, a 300,000 gallon oxidation ditch including two horizontal 42-inch diameter blade aeration rotor/motor assemblies, and an adjustable weir plate, an oxidation ditch flow splitter box (distribution box #1), a 300,000 gallon oxidation ditch (ditch #2) with two (2) horizontal 42-inch diameter blade aeration rotor/motor assemblies, and one adjustable effluent weir, an 18-inch transfer pipe with sluice gate between the two oxidation ditches, and a 1,667 gpm recycle pump between the two ditches, a 32-foot diameter, 12-foot side water depth center -fed secondary clarifier, a clarifier flow splitter box (distribution box #2), a 1.5 mgd UV disinfection facility consisting of three (3) banks in series (2 banks duty, 1 bank redundant), a turbidity meter, an effluent reclaimed water pump station consisting of three (3) 521 gpm, 30 hp vertical turbine pumps, a three-way control effluent valve, and pumped effluent magnetic flowmeter, a 4.28 million gallon upset pond lined with 60 mil HDPE synthetic liner, and a upset pond pump station including a 210 gpm pump, RAS/WAS pump station including dual 520 gpm pumps, and 15 hp pumps, a chlorination feed system for internal WWTP algae maintenance, a 46,900 gallon sludge digester, a 500 gpm, 8 hp sludge transfer pump, a 315,000 gallon sludge holding stainless steel tank with fine bubble diffusers, dual 806 scfm, 40 hp air blowers, a sludge loading station (for trucks) with 500 gpm sludge transfer pump, one 350 kW emergency generator with automatic transfer switch, and associated yard piping and appurtenances, Reclaimed Water Distribution. Force Main approximately 32,200 linear feet of 12-inch reclaimed water force main and associated appurtenances, Reclaimed Water Low Rate Infiltration Basin Disposal Facility four reclaimed water infiltration ponds (totaling 600,000 gpd disposal capacity) including Basin #1 (5.00 acres), Basin #2A (2.88 acres), Basin #2B (3.88 acres), and Basin 43 (3.48 acres), associated groundwater underdrain trench/pipe system, and associated piping, appurtenances, and access roads, to serve the Town of Swansboro WWTF with no discharge of wastes to surface waters, pursuant to the application received October 15, 2009, and in conformity with the project plans, specifications, and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources and considered apart of this permit. This permit shall be effective from the date of issuance until September 25, 2014, shall void Permit No. WQ0023261 issued September 26, 2006 and shall be subject to the following specified conditions and limitations: I. PERFORMANCE STANDARDS 1. Only tertiary treated wastewater generated from the Town of Swansboro Wastewater Treatment Plant which meets the reclaimed water standards as defined by 15A NCAC 2H.0219(k) shall be disposed of at the reclaimed water utilization facilities. If at any time the WWTP effluent does not comply with these standards, discharge into the reclaimed water distribution system shall 'immediately cease and shall not resume until the effluent meets the reclaimed water standards. 2. The issuance of this permit shall not relieve the Permittee of the responsibility for damages to groundwater or surface water resulting from the operation of this facility. 3. Diversion or bypassing of the untreated wastewater from the treatment facilities is prohibited. 4. Any sludge generated from this disposal facility must be disposed of in accordance with General Statute 3143-215.1 and in a manner approved by the North Carolina Division of Water Quality. 5. The following buffers shall be maintained: a. 100 feet between wetted areas and water supply wells, b. 100 feet between wetted areas and waters classified as SA, c. 25 feet between wetted areas and surface waters not classified as SA, d. 100 feet between wastewater treatment units and wells, e. 50 feet between reclaimed water storage/irrigation ponds and property lines, and f. 50 feet between wastewater treatment units and property lines. 6. All reclaimed water valves, storage facilities, outlets shall be tagged or labeled to warn the public or employees that the water is not intended for drinking. Where appropriate, such warning shall inform the public or employees to avoid contact with the water. W00023261 Version 1.3 Page 2 of 11 7. All reclaimed water piping, valves, outlets and other appurtenances shall be color -coded, taped, or otherwise marked to identify the source of the water as being reclaimed water. a. All reclaimed water piping and appurtenances shall be either colored purple (i.e., Pantone 522) and embossed or integrally stamped or marked "CAUTION: RECLAIMED WATER - DO NOT DRINK" or be installed with a purple (i.e., Pantone 522) identification tape or polyethylene vinyl wrap. The warning shall be stamped on opposite sides of the pipe and repeated every three feet or less. b. Identification tape shall be at least three inches wide and have white or black lettering on purple (i.e., Pantone 522) field stating "CAUTION: RECLAIMED WATER - DO NOT DRINK". Identification tape shall be installed on top of reclaimed water pipelines, fastened at least every 10 feet to each pipe length and run continuously the entire length of the pipe. c. Existing underground distribution systems retrofitted reclaimed water shall be taped or otherwise identified identification need not extend the entire length of the incorporated line. for the purpose of distributing as in items a. or b. above. This distribution system but shall be within 10 feet of crossing any potable water supply line or sanitary sewer 8. All reclaimed water valves and outlets shall be of a type, or secured in a manner, that permits operation by authorized personnel only. 9. Above -ground hose bibs (i.e., spigots or other hand -operated connections) shall not be present. Hose bibs shall be located in locked below -grade vaults that shall be clearly labeled as being of non -potable quality. As an alternative to the use of locked below -grade vaults with standard hose bibs services, hose bibs, which can only be operated by a special tool may be placed in non -lockable underground services boxes clearly labeled as non -potable water. 10. The Permittee shall maintain an active cross -connection control program that shall have the following minimum requirements: a. No direct cross -connections shall be allowed between the reclaimed water and potable water systems. b. A reduced pressure principle backflow preventer, an approved air gap separation, or other device approved by the Division of Environmental Health shall be installed at the potable water service connection to the use area where both reclaimed water and potable water are supplied to a reclaimed water use area. The installation of the reduced pressure principle backflow prevention device shall allow proper testing. c. An air gap separation, approved and regularly inspected by the potable water supplier, shall be provided between the potable water and reclaimed water systems where potable water is used to supplement a reclaimed water system. W00023261 Version 1.3 Page 3 of 11 Reclaimed Water Low Rate Infiltration. Basin Disposal Facility 11. The reclaimed water utilization facilities shall be effectively maintained and operated at all times so that there is no discharge to the surface waters, nor any contamination of groundwaters which will render them unsatisfactory for normal use. In the event that the facilities fail to perform satisfactorily, including the creation of nuisance conditions or failure of the infiltration area to adequately assimilate the wastewater, the Permittee shall take immediate corrective actions including those actions that may be required by the Division of Water Quality (Division), such as the construction of additional or replacement wastewater treatment and disposal facilities. 12. Public access to the infiltration sites shall be controlled during active site use. Such controls may include the posting of signs showing the activities being conducted at each site. A sign shall be posted in plain sight showing these activities. II. OPERATION AND MAINTENANCE REQUIREMENTS 1. The facility shall be properly maintained and operated at all times. 2. Upon classification of the wastewater treatment and infiltration facilities by the Water Pollution Control System Operators Certification Commission (WPCSOCC), the Permittee shall designate and employ a certified operator to be in responsible charge (ORC) and one or more certified operator(s) to be back-up ORC(s) of the facilities in accordance with 15A NCAC 8G .0201. The ORC shall visit the facilities in accordance with 15A NCAC 8G .0204 or as specified in this permit and shall comply with all other conditions specified in these rules. - 3. The Permittee shall install all appropriate flow measurement devices consistent with approved engineering and scientific practices to ensure accuracy and reliability of influent flow measurement. Flow measurement devices selected shall be capable of measuring flows with a maximum deviation of less than 10 percent from true flow, accurately calibrated at a minimum of once per year, and maintained to ensure that the accuracy of the measurement is consistent with the accepted capacity of that type of device. Records of flow measurement device calibrations shall be kept on file by the Permittee for a period of at least three years. At a minimum, data to be included in this documentation shall be: a. Date of flow measurement device calibration b. Name of person performing calibration c. Percent from true flow 4. Should the limit for fecal coliform (daily maximum concentration of 25 per 100 ml) or turbidity (instantaneous maximum of 10 NTU) be exceeded, all wastewater shall be handled in one of two ways, until the levels have stabilized below these maximum levels. The Town of Swansboro Wastewater Treatment Plant may further treat the wastewater to bring it into compliance with reclaimed water standards without returning the water to the facility's headworks, or may reroute it to the headworks of the wastewater treatment facility for treatment to reuse standards. WQ0023261 Version 1.3 Page 4 of 11 Reclaimed Water Low Rate Infiltration Basin Disposal Facility The facilities shall be effectively maintained and operated as a non -discharge system to prevent the discharge of any wastewater resulting from the operation of this facility. 6. No type of wastewater other than that from the Town of Swansboro's wastewater treatment plant shall be irrigated at the Reclaimed Water Low Rate Infiltration Basin Disposal Facility. 7. The infiltration rates shall be according to the following table. Basin Wetted Acreage Infiltration Pond Surface Loading Rate Q d/fe) Maximum Annual Irrigation Qallons/year) Annually Averaged Irrigation gallons/day) 1 5.00 0.9044 71,897,087 196,980 2A 2.88 0.9044 41,412,722 113,460 2B 3.88 0.9044 55,792,139 152,860 3 3.48 0.9044 50,040,372 137,100 Total 15.24 219,142.321 600,400 IILMONITORING AND REPORTING REOUIREMENTS 1. Any monitoring (including groundwater, surface water, soil or plant tissue analyses) deemed necessary by the Division of Water Quality to insure surface and ground water protection will be established, and an acceptable sampling reporting schedule shall be followed, 2. WWTP reuse effluent flow shall be continuously monitored and daily flow values shall be reported on Form NDMR-1. Infiltration at the Reclaimed Water Low Rate Infiltration Basin Disposal Facility shall be continuously monitored and daily flow values shall be reported on Form NDAR-1. 3. As an indicator of proper operation and maintenance, the Town of Swansboro Wastewater Treatment Plant shall produce an effluent in compliance with the following reclaimed water limitations: Parnm&,ter BOD5 (5-day, 20°C) NH3 as N TSS Fecal Coliform Turbidity Monthly Average a Daily (Instantaneous) Maximum 10 mg/l 15 mg/l 4 mg/l 6 mg/l 5 mg/l 10 mg/I 14 per 100 ml b 25 per 100 ml 10 NTU W00023261 Version 1.3 Page 5 of 11 a. Monthly averages for all but fecal coliform shall be the arithmetic mean of all samples collected during the reporting period. b. Monthly average for fecal coliform shall be the geometric mean of all samples collected during the reporting period. c. Daily maximum shall be the maximum value of all samples collected during the reporting period. The effluent from the subject facilities shall be monitored, by the Permittee, at the point prior to or at the WWTP effluent reclaimed water pump station for the following parameters and reported on Form NDMR-1: Parameter Sampling Point Sampling Frequency Type of Sam121 Flow Influent Continuous Recording Stage Level' Infiltration Basin #1 Daily Measured Stage Level' Infiltration Basin #2A Daily Measured Stage Level' Infiltration Basin #2B Daily Measured Stage Level' Infiltration Basin #3 Daily Measured Turbidity Effluent Continuous Recording Residual Chlorine Effluent Daily Grab Settleable Matter Effluent Daily Grab BOD5 (5-day, 20°C) Effluent 2/Monthb Composite TSS Effluent 2/Monthb Composite Fecal Coliform Effluent 2/Monthb Grab NH3 as N Effluent 2/Monthb Composite NO3 Effluent 2/Monthb Composite TKN Effluent 2/Monthb Composite TDS Effluent Triannuallyc Grab TOC Effluent Triannually° Grab Chloride Effluent Triannually° Grab The effluent pH shall not be less than 6.0 standard units nor greater than 9.0 standard units. Daily water stage level of each basin (Basin #1, #2A, #2B, and #3) as measured in feet (freeboard below top of berm). b 2/Month sampling frequency only during the months of April through October. During the remainder of the year, these parameters shall be monitored monthly. Triannually sampling shall be conducted during March, July, and November. If groundwater sampling indicates or predicts problems with the compliance with Groundwater Standards, this permit will be modified to include additional and/or more restrictive limitations. W00023261 Version 1.3 Page 6 of 11 4. Adequate records shall be maintained by the Permittee tracking the amount of wastewater disposed at the Town of Swansboro Reclaimed Water Low Rate Infiltration Basin Disposal Facility, and reported on Form NDAR-2. These records shall include, but are not necessarily limited to, the following information: a. date and time of wastewater volume infiltrated to each basin: Parameter Sampling Point Sampling Frequency Type of Sample Flow to Basin #le Effluent As Used Recording Flow to Basin #2Aa Effluent As Used Recording Flow to Basin 9-2Ba Effluent As Used Recording Flow to Basin #3a Effluent As Used Recording a Reclaimed water effluent daily flout pumped to each basin (Basin #1, #2A, #2B, and #3). b. continuous weekly, monthly, and year-to-date hydraulic (gpd{ft2) loadings for each basin, and e. weather conditions. 5. Three (3) copies of all effluent monitoring data (as specified in condition III 3) on Form NDMR-1 and three (3) copies of all operation and disposal records (as specified in condition Ill 4) shall be submitted on or before the last day of the following month. All information shall be submitted to the following address: NC Division of Water Quality Information Processing Unit 1617 Mail Service Center Raleigh, North Carolina 27699-1617 6. A maintenance log shall be maintained at the Town of Swansboro Wastewater Treatment Plant including, but not limited to, the following items: a. Daily sampling results including residual chlorine, settleable matter, and dissolved oxygen in the aeration basin and at the clarifier weir. b. Visual observations of the plant and plant site. c. Record of preventative maintenance (changing of filters, adjusting belt tensions, alarm testing, diffuser inspections and cleanings, etc.). d. Date of calibration of flow measurement device. e. Date and results of power interruption testing on alternate power supply. 7. A maintenance log shall be maintained at the Town of Swansboro Reclaimed Water Low Rate Infiltration Basin Disposal Facility including, but not limited to, the following items: a. Visual observations of the infiltration basins. b. Record of preventative maintenance (pump maintenance, infiltration basin maintenance, etc.). c. Date of calibration of flow measurement device, W00023261 Version 1.3 Page 7 of 11 8. Noncompliance Notification: The Permittee shall report by telephone to the Wilmington Regional Office, telephone number (910) 796-7215, as soon as possible, but in no case more than 24 hours or on the next working day following the occurrence or first knowledge of the occurrence of any of the following: a. Any occurrence at the wastewater treatment facility which results in the treatment of significant amounts of wastes which are abnormal in quantity or characteristic, such as the dumping of the contents of a sludge digester; the Down passage of a slug of hazardous substance through the facility; or any other unusual circumstances. b. Any process unit failure, due to known or unknown reasons, that render the facility incapable of adequate wastewater treatment such as mechanical or electrical failures of pumps, aerators, compressors, etc. c. Any failure of a pumping station, sewer line, or treatment facility resulting in a by-pass directly to receiving waters without treatment of all or any portion of the influent to such station or facility. d. Any time that self -monitoring information indicates that the facility has gone out of compliance with its permit limitations. Occurrences outside normal business hours may also be reported to the Division's Emergency Response personnel at telephone number (800) 662-7956, (800) 858-0368, or (919) 733-3300. Persons reporting such occurrences by telephone shall also file a written report in letter form within five (5) days following first knowledge of the occurrence. This report must outline the actions taken or proposed to be taken to ensure that the problem does not recur. IV. GROUNDWATER REQUIREMENTS Reclaimed Water Low Rate Infiltration Basin Disposal Facility 1. All wells that are constructed for purposes of groundwater monitoring shall be constructed in accordance with 15A NCAC 2C .0108 (Standards of Construction for Wells Other than Water Supply) and any other state and local laws and regulations pertaining to well construction. 2. Groundwater monitor wells MW-1, MW-2, and MW-3, and Surface Water Sampling Point SW-1 *, shall be sampled initially after construction of the wells, and thereafter every March, July and November for the following parameters: WQ0023261 Version 1.3 Page 8 of 11 Water Level Chloride Total Ammonia (as N) Total Dissolved Solids (TDS) pH Fecal Coliform Nitrate (NO3-N) Total Organic Carbon (TOC) Volatile Organic Carbon (VOC) analysis - Only in November for MW4, MW-2 and MW-3 (not Surface Water Sampling Point SW-1) *Surface Water sampling Point SW-1 is located in the un-named stream about 80 feet from Discharge Outlet DO #1 (see Sheet 1-7). "For monitor wells MW-1, MW-2 and MW-3 only. The measurement of water levels must be made prior to sampling for the remaining parameters. The depth to water in each well shall be measured from the surveyed point on the top of the casing. The measuring points (top of well casing) of all monitoring wells shall be surveyed to provide the relative elevation of the measuring point for each monitoring well. For Volatile Organic Compounds (VOCs) sampled in November, use only one of the following methods: a. Standard Method 6230D, Practical Quantitation Limit (PQL) at 0.5 ug/L or less b. Standard Method 6210, PQL at 0.5 ug/L or less c. EPA Method 8021, Low Concentration, PQL at 0.5 ug/L or less d. EPA Method 8260, Low Concentration, PQL at 0.5 ug/L or less e. Another method with prior approval by the Aquifer Protection Section Chief Any of the referenced methods used for VOCs must at a minimum, include all the constituents listed in Table V111 of Standard Method 6230D. Any method used must provide a PQL of 0.5 ug/L or less, which must be supported by laboratory proficiency studies as required by the DWQ Laboratory Certification Unit. Any constituents detected above the Method Detection Limit (MDL) but below the PQL of 0.5 ug/L must be qualified (estimated) and reported. Any laboratory selected to analyze parameters must be Division of Water Quality (DWQ) certified for those parameters required. The results of the sampling and analysis must be received on Form GW-59 (Groundwater Quality Monitoring: Compliance Report Form) on or before the last working day of the month following the sampling month. Send all forms to: NC DENR/DWQ Information Processing Center 1617 Mail Service Center Raleigh, NC, 27699-1617. WQ0023261 Version 1.3 Page 9 of 11 3. The compliance boundary and review boundary for wastewater disposal systems are specified by 15A NCAC 2L. For systems utilizing reclaimed water, 15A NCAC 2H .0219(k) specifies that both the compliance boundary and review boundary shall be established at the property line. An exceedance of groundwater quality standards at or beyond the compliance boundary is subject to immediate remediation action in addition to the penalty provisions under North Carolina General Statute 3�143-215.6A(a)(1). V. INSPECTIONS 1. Adequate inspection, maintenance, and cleaning shall be provided by the Permittee to insure proper operation of the subject facilities. 2. The Permittee or his designee shall inspect the wastewater treatment and disposal facilities to prevent malfunctions and deterioration, operator errors and discharges which may cause or lead to the release of wastes to the environment, a threat to human health, or a nuisance. The Permittee shall keep an inspection log or summary including at least the date and time of inspection, observations made, and any maintenance, repairs, or corrective actions taken by the Permittee. This log of inspections shall be maintained by the Permittee for a period of three years from the date of the inspection, and shall be made available upon request to the Division of Water Quality or other permitting authority. 3. Any duly authorized officer, employee, or representative of the Division of Water Quality may, upon presentation of credentials, enter and inspect any property or premises on or related to the disposal site and facility at any reasonable time for the purpose of determining compliance with this permit; may inspect or copy any records that must be kept under the terms and conditions of this permit; or may obtain samples of groundwater, surface water, or leachate. VI. GENERAL CONDITIONS 1. This permit shall become voidable unless the facilities are constructed in accordance with the conditions of this permit, the approved plans, specifications, and other supporting data. 2. This permit is effective only with respect to the nature and volume of wastes described in the application and other supporting data. 3. This permit is not transferable. In the event there is a desire for the facilities to change ownership, or there is a name change of the Permittee, a formal permit request must be submitted to the Division of Water Quality accompanied by an application fee, documentation from the parties involved, and other supporting materials as may be appropriate. The approval of this request will be considered on its merits and may or may not be approved. 4. Failure to abide by the conditions and limitations contained in the permit may subject the Permittee to an enforcement action by the Division of Water Quality in accordance with North Carolina General Statute 5143-215.6A to 6143-215.6C. WQ0023261 Version 1.3 Page 10 of 11 5. The issuance of this permit does not exempt the Permittee from complying with any and all statutes, rules, regulations, or ordinances which may be imposed by other government agencies (local, state, and federal) which have jurisdiction, including but not limited to applicable river buffer rules in 15A NCAC 2B .0200, erosion and sedimentation control requirements in 15A NCAC Chapter 4 and under the Division's General Permit NCG010000, and any requirements pertaining to wetlands under 15A NCAC 2B .0200 and 2H .0500. 6. A set of approved plans and specifications for the subject project must be retained by the Permittec for the life of the project. 7. The annual administering and compliance fee must be paid by the Permittee within thirty (30) days after being billed by the Division. Failure to pay the fee accordingly may cause the Division to initiate action to revoke this permit as specified by 15 NCAC 2H .0205(c)(4). The Permittee, at least six (6) months prior to the expiration of this permit, shall request its extension. Upon receipt of the request, the Commission will review the adequacy of the facilities described therein, and if warranted, will extend the permit for such period of time under such conditions and limitations as it may deem appropriate. Permit issued this the 27`h day of October 2009. NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION I ale . Sullins, Director Division of Water Quality By Authority of the Environmental Management Commission Permit No. WQ0023261 WQ0023261 Versbn 1.3 Page 11 of 11 UMITS OF DISTURBANCE 4-im is- WON wL TIAN D5 -c M p mole i of r c f, JR& "nG9ary '0 UNDERDRAIN GREEN ENGINIEEF WATER, WASTEWATER, SURVEYING~ PLANNNGC f BRA NCH PARKEFITOWN ROAD (SR A32) 2DOE btiALL DENT- SWANS PROJECT Nc. E97-a72.5 A59FgWN6a7,655.686,757 :FIAM1G� 9A is AAAY zoa6 JL r UHpERDRAIN SCHEDULE r • '� a = � .. �� � �,''-� STRII[:TiIRF ME 9� * \ ' $ f\_ J a° .�• - �^-,.i Lw'011Af£ wqu f F - 27.00 1 :� }�, crFnNolh /T 36.T10 27-22 -,`-.. '- �' - -- '.. - - ..-.'�`•`� �k11t{IS OF�� is CLEANOUT 12 41.00 27.59 �'+ '�•''' .. r.� Wow", w, - ""., - - _ DISRROHAItGE' CLEANOLIj g3 41.00 27.77 iR. ---=.-'.f CLEANOUT j4 3a.00 27.97 } - _ �.A CLEANOUT 05 37.00 28.13 Is CLEANOUT 05 40.OD 27.73 si '-' 1 V4 CLEANOUT #7 40.00 27,93- CLEANOUT /8 39.00 28.21-.- CL EANOUT 09 39.00 28.38-- E SAE SCHEDULE -� JWilf i s SRUCnIRF L n SEGf m TR* f 1 30. 15' 3' 10' 01�RT OCSIPAI® /1 CiA55 'A STONE 1�1 BASIN t area @ HWL 218.009 sq. k - ' 5.00 aces71, �lR A � .• .� NWL-3B.00 , A'EEO Ar � .0 \ - 12'0 NON-PERTORAIEO BOTTOM = 32.09 _ PIPE 11 i- SPLASH PAD // 'y, p4�1 i� I s ti J 4J f } (SEA nErAL &IEET) "47"p 1 -M I. - 'tea-='- :�.- -_ ��O-• _ _ 7 c EMCC Lv STOCK PILE AREA (SEE OVERALL PLAN] ULM OF 9 ♦+-....-,r xj $PggBT6GH PILE AR A (SEE OVERALL PLAN) `~TIw. 1� `• S '>i 'il it -�Y _ i � t'` y �� y j. S. E R GREEN ENCaINEERINGI TOWN OF SWANSBOAO GRADING PLAN WAIER WASTEWATER 9UFNEYNIQ MLANNL1q PROJECT MAMAUEMENT +r f "i`��` 721MuoLeemrlXDT. PA.BOKEDY LVLeorLRC.Q]5P1 LOW HATE INFILTRATION BASINS BASIN 1 'rrL LiR +L+` +u [ter an�5s PAX Eux1 x.LrTrm oR;ce.oRF�rncaa CNSLOW COUTaTY NORTH CAROLINA io, LOCATION KEY EROSION CONTROL NOTES WI+EN SFFDIKC u,w cNINC IO BE APPLILO N at 0-5 pr— _0 OlsrVwBlNc NOT PREVIOUSLY STA©EL17CO SILT ACTIv.TC5 rEmcE TO 9! INSTALLED AS SHOWN OR AS DEEMED NECUISARY BT' WSWL Onc r,ATKR1. $VAT FENCE ROCK ChICK DAM Q OIssPAiOR PAO Ir..LT rNDIECLUK seo+n.rrrr rNAr f ELTFR eASIN LEGEND _ E.Isr>«c „Nx I.Q PRnPDSED uA O(E A PROPesEp 5'. A-SER LLLANrOUT - PROPtISEC wLNE ►� - s LB rya PAOP SS 17'. fu ,.FM PRDP UC IY-. URArri -- 12.Ub crlsiaKp , CONIP/R- E-SrNK: S' EOw" -- —w— P-OP. ------ -- --{ ' ,, COWCUR PROP S COnrObk —� LWITS or DISTURBANCE Y r r w r w w w r w .T ILMIIS - ,.rrll.l 9 I .Rf a 1-5 Q 12 UNaJ=RURAIN SGHV OULE gAr a " U1405 bF Y ' "rr ar UCTURl= ME IfflL "_ T R � � _ - � . � j . - `DISTugSAl4CE n, j _ f 1 _ * ,r?� -'" •. l- STOLIK PILEpAREIL 1=,J•- 4-f.- N �► w>7�1 ��' _ _ (SEE OVERALL PiJ1Nj vw c1_r.WPITT it 32.49 23.46..., ' -i ; k -1.: r. !s`• - - a CLEANOUf 12 42.3124.14ti ~ a CLEANEWT j3 4l.53 24.76= - k•- " = ly►1 --F ._ : - �. ;2 ,p -. �� _ '? f �I CLEANOLri J4 34.95 25.20 - - —�-� (��.,..]f' - �.•t ` -_ e f CLEANOLIT #5 41.00 25.Es- v " .• CLEANOLrT #8 45.00 26.48 Jy ♦ ''-- �,�, ; r ,, . ' CLEAPIOUT r7 41,00 26.74 ' � � .� \ - - �a' .� {- .N, . STOCK PILE AREA 1 (SEE OVERALL PLAN] � *-_ _ BASIN 2A \� 125,328 sq. ft. SIP N PAD Y •3�-f1'�I' - _ ,T �Q: - 2.86acres (SEE DE7A1L SHk� .. �� a - _ -•/'4'BOTTOM = 33.0_0 •Y - ` , SPLILSH PAD 1s e>, 1 � -n (SEE DETAIL SHEF:iJ `I,� B C 1' ><I '1 R x II - _ I lip � + _ `� 'dy`_._ n° ^�' - -' v riv,'� Is.` fr - �`�•�i\W [, BASIN 2Bjw 1 T R jr c^ 1 3.88 acres HWL s 3B.OQ •�'' ? k'r r � BOTTOM = 32.aa�- +1VI ir`'i�f� x k ,' ; r 11 _ 1• _ :�ti,'fir..!-+ +I M. 65 '4 �03` A 1 P2'0 NON PERFORATED. fI- LOCATION KEY r EROSION CONTROL NOTES SEE WC AND WILCIIING TO 9r APPLIEo wrllln ' II pAVs Of AIL I -A.0 ❑ eV URDINC A_T N11.E5 5 FIAT PRC.O,JslY 1A0IIIIED SILT FENCL TO U'_ '. // $NSIALLLD w5 Sllo tl OR AS MEWED NLSI;.SSAW o' Wsuµ DRjERVwTIpN 4I,L FE III:£ +-+---��-�-�- RD" 1:.1ECx IwA (� �• �ly�jjj'))) NISSPAIOR PN) r'''`I WLCT PROTECioR l l SEDIMENT TRAP I fR1ER RASW LEGEND_ EYISIWG VALVE- Y A+ ." r, ' _ _. (o,77:i) I - - (o.axx! - _ __ _ 1 I�i y , ' , -r--• i7PUP w� 17W0 �•� �� J7eOl/ ��.�....� i7e1N0 r ,- r ♦ ... 4 I PRo p M—ar • L PROPoSEo a, AKER CtL -wr PIIDPOSLL YAWL H i-w oat •`� � I + ; >s � I .�, '. , •_ _ __- �` YI, 41 Ti ' f! i� -� f+NOa SS +i: ru � 1 ' .�` , �.� '.. �. F+ - �.' PROP. Lr. U-. OMPI r r r r r' J a r I 1! _ i `I a .. '+.. \../~ f/ 1 '.;:= `� — i7eilD J �11e+' r r r r a r r+ r r r r Ii r \/T r No [� �E rr rr A. a 11! r r I�F ` f A r'� r% I JA - ExISTatG 1' rDN1U1R -'A A, --._— y`ti /F/�j.cr•1l"v / .r L,-/i Y!' (tiff./•.�{_ - - - -� _'" r L.Av t:+sLnm 5' CONICUR _ S 8 E SCHEDULE L _ -}i- — : y_ �'r_ uAEIT$ OF JA. a� .- PRDF V 0O 10uR — ,�pv STRIIf,TtIRF i W II WELL - - - _ 1 _ ISRJR@INCE-.a r�� - 1j,�_<�• PRDP U, u"TwR -.sEDWF,1Nr TRAP %2A 30' 15' 3' 1 D' k"15 ar oMUMAN W •�}.� 15310' ''^^'' �S&10 '9SD1gW Ke j20 30' , ' XLJ� CC'''' wenAlros L � - ¢ �•._RIDif(g6SNYSpg2A 20'iD'1.5' CLASS A _ L D1i1t "DW NNr' 11211 20' 10 1.5 STONE ."`"""^"-•--. .:,..__„_....,.,�,.,...�.....,_._._.. ,�.,. .`'�. a - --- vl1� +, �' - ..Iit----- GREEN ENGINE£=R1N0 TOWN OF SWANSBORO tr WATER WASTEWATEik sw+W vEYM n-4Nn PROJECTMANILOEAEEHr GRADING PLAN PMDQA s HllllarLNC.27B LOW RATE INFIL.THATION BASINS BASIN 2A $ 2B A7j �R�i;i` TEL I7Kvl 2Tl-SiRi PAIf Lvey su->4eP o POrS743i4caFl pNSIpW COIJN iY NOflTH CAR.1 INA w[LT ro 1..g - 12 e UNDERDRAIN SCHEDULE Y. SffiUGAIBE TOP IK1L 'STOCK FILE: AREA �. - o® � mnEi /t - z3.DO JSEE OVERALL PLANT 'rqt -top CLiANOUT /1 36.20 23.40 l'1E} 1p-�W/ydVa. .. , r _ -Lli- \1�. .* CLEANOUT j2 36.20 23.78 -✓ .� `• - - •-� . , } (o.7iZ�'+F-iif^I , �� ». - -C -- - ♦ ' CLEANOUT #3 36.35 23.97 ,4,♦ .ss' ..- = _ ` F�L�LJ• ,y .: L = ` !1 �, . - ? i . N i '�+ CLEAROUT 04 36.OD 24-15 ♦ ( x - I __ � ` •' -►♦ : _ _- -) ' ` - af`7� MEMOAr 05 35.67 24.J3 1 '_- ~ \\�Aq \t/" - ��� L .S •..� �"- �• 1 CLEANOUr s 36.00 24-88 \ ! ! r r _ + CLENNOLIr /7 36.07 24.05 i-� )f ., � /<, �:.. �_-_;� T+c '-� 3 CLEANOUT is 34.00 24-38 CLEANOUr +9 31.00 24.05 r� £I „ �`� EEI CLEANOUT #10 35-30 23.73 � L CLEAMOUT /T1 29.00 23.33 \ w .p ` ;r,; `' _ �_x } _ ♦t ; a ® - a SPLASH PAR !4� - �LlAlfrS DF Purl/� .. "�° • ~;' (SEe DETAIL SH£ErI r'y''y �� - .-,- DISIi1R, IWCE -7N -; I BASIN 3 area (4 HWL 145 663 sq. fL HVVL = 34.00 j ��� BOTTOM - 28.06 �, AI c` �-_ a r`J �' '3J, f •i ,o!'..'p, 4Y"NON I'ZODRATED Li i - F 'w _l `� STOCK PILE Y r RIPE LOCATION'KEY (SEE _OVERALL PLAN) `;�'�,.•�� -,� -4.';. 'p, EROSION CONTROL NOTES �1 1 1 ��]] /// .fir,- r '� i', •' ' '0�� SEEn C —0 MuLCMNr TO IREr PLIED wiTHiN — 1 �, NOT DFFFv10N51YSTAO .Z P`LR SrLT FEeM,:E'SO DC •+ * o{ l `� , -� ` *r, _ INSrwLi EO I.5 51it1WN CA AS OEEIUED NFCFSia•LLY _ �` ` _ ('r - BY VLSVAL COSERYATHIN VIA1w1 - e \ / !� / W r-��1 _ -'' �` �-y _�i����L_ 5pt FFUCE �a s� II �JFrYY to-0 Wssiaw,ore C �I 1•� iZ PNUN PERFORATED ; ii� —El P.-JrEr:IOR ®,si-_� LEGEND -'_-------'------�' L = J PFOP-SED u"HOLE yyqq ��-J•F Ir r r W r r ��i1 r � w r.� M4 � a• +1{ /� ' f � �. i� 1 PROPOS{D 6'r HiSER CLVM—b11 LINIfS OF /;P 'r rm G ./f PnoPozFD Y.LYt' ii {ter% r ��,r1 , BLSiUR9ALICE r WLO WRE -E - - _ _ - _ _ ,_ r ' �', a -yv�y_ _ i : -�, wed s5 i]-r ru 129FM i i. -YWA-f 77 •%7' co,nn'.1 _ 4. ..-. _ . -A.-- - - j P 0D t' COHfOUt {1 - �jf J ' +' i PROP s -Mlo m CSP.f- FE$u7rJ� [ trQJ1rt �S �'7 ii ti E wrs or nis vneR»ce w r w r .w r r a r r ■ o _ r�t4r-j�je r ,► i NETIAM S oe O -ter w. 1 u GFiE=EN ENOINEERING f WASTE WATER TOWN OF SWANSBORO R GRADING PLAN �WASTEWATER 61.FlVETWD, u1H►a, tiloaecs MuucJeLrrrT r. r ,lFp GRr�Et';.' 61NDO tiHBCNO IT P�L�. ,�N� LOW RATE INFILTRATION BASINS BASIN 3' `W ` TE1 ISi9E]k7-sins r u caatis,}T,w oJwace.oFr�srarnFn ON91UW COUNTY NoRTT{CAi10 Nn "- - I - 12