HomeMy WebLinkAboutWQ0020679_Final Permit_20020618_O��F WAr�9QG Michael F. Easley, Governor
q William G. Ross Jr., Secretary
North Carolina Department of Environment and Natural Resources
C-31;jjii�Alan W. Klimek, P.E., Director
Division of Water Quality
June 18, 2002
STEVEN C. BIGGS
1414 STALLINGS ROAD
DURHAM, NC 27703
Subject: PERMIT NO. WQ0020679
Steven C. Biggs
Single Family Residence
Spray irrigation Facility
Durham County
Dear Mr. Biggs:
In accordance with your request received November 7, 2001 and additional information received on
March 4, 2002 and May 31, 2002, we are forwarding herewith Permit No. WQ0020679, dated June 18, 2002, to
Steven C. Biggs for the construction and operation of the subject single family wastewater treatment and spray
irrigation facilities.
This permit shall be effective to the date of issuance until May 31, 2007, and shall be subject to the
conditions and limitations as specified therein. Please pay particular attention to the monitoring requirements in
this permit. Failure to establish an adequate system for collecting and maintaining the required operational
information will result in future compliance problems.
If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to
request an adjudicatory hearing upon written request within thirty (30) days following receipt of this permit. This
request must be in the form of a written petition, conforming to Chapter 150B of the North Carolina General
Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, NC 27699-
6714. Unless such demands are made this permit shall be final and binding.
One set of approved plans and specifications is being forwarded to you. If you need additional
information concerning this matter, please contact Nathaniel Thornburg at (919) 733-5083 extension 533.
Sinc e ,
.,(Alan W. Klimek, P.E.
cc: Durham County Health Department
Raleigh Regional Office, Water Quality Section
Technical Assistance and Certification Unit
Non -Discharge Compliance/Enforcement Unit
Bryan Staley — Duane K. Stewart & Associates
Water Quality Central Files
NDPU Files
Non -Discharge Permitting Unit Internet http://h2o.car.state-ne.us/ndpu
1617 Mail Service Center, Raleigh, NC 27699-1617 Telephone (919) 733-5083 Fax (919) 715-6048
DENR Customer Service Center Telephone 1 800 623-7748
An Equal Opportunity Action Employer 50% recycled/10% post -consumer paper
NORTH CAROLINA
ENVIRONMENTAL MANAGEMENT COMMISSION
DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES
RALEIGH
SINGLE FAMILY SPRAY IRRIGATION PERMIT
In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended,
and other applicable Laws, Rules, and Regulations
PERMISSION IS HEREBY GRANTED TO
Steven C. Biggs
Durham County
FOR THE
construction and operation of a 360 gallon per day (GPD) spray irrigation wastewater treatment and disposal
system consisting of a 1,000 gallon baffled septic tank, two (2) primary 168 square foot (ft) parallel gravity dosed
subsurface sand filters with a 1.07 gpolf 2 design loading rate, a secondary 168 ft2 gravity dosed subsurface sand
filter with a 2.14 gpd/f 2 loading rate, a tablet chlorinator, a chlorine contact chamber, a 1,500 gallon tank
interconnected with a 2,400 tank to serve as a storage/pump tank with a 14.2 gallon per minute (GPM) pump
operating at 123.6 feet of TDH with high water alarms and rain sensor, and a 14,070 ft2 fenced spray irrigation
area with 3 spray heads to serve the Biggs residence, and all associated piping and appurtenances with no
discharge of wastes to the surface waters, pursuant to the application received November 7, 2001 and additional
information received on March 4, 2002 and May 31, 2002, and in conformity with the project plan, specifications,
and other supporting data subsequently fled and approved by the Department of Environment and Natural
Resources and considered a part of this permit.
This permit shall be effective from the date of issuance until May 31, 2007, and shall be subject to the
following specified conditions and limitations:
I. PERFORMANCE STANDARDS
Upon completion of construction and prior to operation of this permitted facility, a certification must
be received from a professional engineer certifying that the permitted facility has been installed in
accordance with this permit, the approved plans and specifications, and other supporting materials. If
this project is to be completed in phases and partially certified, you shall retain the responsibility to
track further construction approved under the same permit, and shall provide a final certificate of
completion once the entire project has been completed. Mail the Certification to the Non -Discharge
Permitting Unit, 1617 Mail Service Center, Raleigh, NC 27699-1617.
2. The Raleigh Regional Office, telephone number (919) 571-4700, shall be notified at least forty-eight
(48) hours in advance of operation of the installed facilities so that an in -place inspection can be
made. Such notification to the regional supervisor shall be made during the normal office hours from
8:00 a.m. until 5.00 p.m. on Monday through Friday, excluding State Holidays.
3. The spray irrigation facilities shall be effectively maintained and operated at all times so that there is
no discharge to the surface waters, nor any contamination of ground waters which will render them
unsatisfactory for normal use. In the event that the facilities fail to perform satisfactorily, including
the creation of nuisance conditions or failure of the irrigation area to adequately assimilate the
wastewater, the Permittee shall take immediate corrective actions including those actions that may be
required by the Division of Water Quality (Division), such as the construction of additional or
replacement wastewater treatment and disposal facilities.
4. The issuance of this permit shall not relieve the Permittee of the responsibility for damages to surface
or ground waters resulting from the operation of this facility.
5. The sand media of the primary and secondary gravity dosed subsurface sand filters must comply with
the Division's sand specifications. The Engineer's Certification will serve as evidence that these
specifications have been met.
6. A leakage test shall be performed on the septic tank and storage/pump tanks to insure that any
exfiltration occurs at a rate which does not exceed twenty (20) gallons per twenty-four (24) hours per
1,000 gallons of tank capacity. The Engineer's Certification will serve as proof of compliance with
this condition.
7. If excavation into bedrock is required for the installation of the septic tank or sand filter, the pit shall
be lined with a 10 mil synthetic liner.
8. A sanitary tee and filter shall be installed on the effluent pipe of the septic tank. The Engineer's
Certification will serve as evidence that these specifications have been met.
9. The residuals generated from these treatment facilities must be disposed in accordance with General
Statute 143-215.1 and in a manner approved by the Division.
10. Diversion or bypassing of the untreated wastewater from the treatment facilities is prohibited.
11. The following buffers shall be maintained:
a) 400 feet between wetted area and any residence or places of public assembly under separate
ownership,
b) 150 feet between wetted area and property lines,
c) 100 feet between wetted area and wells,
d) 100 feet between wetted area and drainage ways or surface water bodies,
e) 50 feet between wetted area and public right of ways,
f) 100 feet between treatment/storage, units and any wells, and
g) 50 feet between treatment units and property lines.
1.2. The pump tanks shall have functional high water audible and visual alarms. The name and
number of an emergency contact shall be posted in a conspicuous location.
13. The disposal system shall be connected to a rain or moisture sensor that shall indicate when
wastewater application is not appropriate in accordance with Condition II(4) of this permit.
2
II. OPERATION AND MAINTENANCE REQUIREMENTS
The facilities shall be properly maintained and operated at all times.
2. Upon classification of the facility by the Water Pollution Control System Operators Certification
Commission (WPCSOCC), the Permittee shall employ a certified wastewater treatment plant operator
to be in responsible charge (ORC)-of the wastewater treatment facilities. The operator must hold a
certificate of the type and grade equivalent to or greater than the classification assigned to the
wastewater treatment facilities by the WPCSOCC. The Permittee must also employ a certified back-
up operator of the appropriate type and grade to comply with the conditions of 15A NCAC 8G .0202.
The ORC of the facility must visit each Class I facility at least weekly and each Class II, III, and IV
facility at least daily, excluding weekends and holidays, and must properly manage and document
daily operation and maintenance of the facility and must comply with all other conditions of 15A
NCAC 8G .0202. Once the facility is classified, the Permittee must submit a letter to the WPCSOCC
which designates the operator in responsible charge within thirty days after the wastewater treatment
facilities are 50% complete.
A suitable year round vegetative cover shall be maintained.
4. Irrigation shall not be performed during inclement weather or when the ground is in a condition that
will cause runoff.
Adequate measures shall be taken to prevent wastewater runoff from the spray field.
6. The application rate shall not exceed a cumulative loading of 26 inches over any twelve (12) month
period at an instantaneous application rate not to exceed 0.10 inches per hour_
7. The facilities shall be effectively maintained and operated as a non -discharge system to prevent the
discharge of any wastewater resulting from the operation of this facility.
No type of wastewater other than that from the Biggs residence shall be sprayed onto the irrigation
area.
No traffic or equipment shall be allowed on the disposal area except while installation occurs or while
normal maintenance is being performed.
10. The spray irrigation field shall be fenced with at least a two -strand wire fence.
11. The Permittee is responsible for the operation and maintenance of the entire treatment and disposal
system including, but not limited to, the following items:
a. The septic tank shall be checked annually and pumped out as needed.
b. The tablet chlorinator shall be checked every week. Tablets shall be added to provide proper
chlorination.
c. The storage, pump, and alarm systems shall be inspected monthly. The scum layer shall be
removed at the same interval as the septic tank is cleaned out.
d. The spray system shall be inspected monthly to make certain of the sprayers proper operation,
that the vegetative growth allows a proper spray pattern, that the soil is assimilating the disposed
treated wastewater with no surface runoff, and that no objectionable odors are being generated.
III. MONITORING AND REPORTING REQUIREMENTS
Any monitoring deemed necessary by the Division to insure surface and ground water protection will
be established and an acceptable sampling reporting schedule shall be followed.
2. The Permittee shall maintain records of all maintenance performed on the system and irrigation area,
as required in Condition II(11) fora minimum of five years. This information shall be provided to
the Division upon request.
Noncompliance Notification:
The Permittee shall report by telephone to the Raleigh Regional Office, telephone number (919) 57I-
4700, as soon as possible, but in no case more than 24 hours or on the next working day following the
occurrence or first knowledge of the occurrence of any of the following:
a. Any process unit failure, due to known or unknown reasons, that renders the facility incapable of
adequate wastewater treatment, such as mechanical or electrical failures of pumps, spray heads,
etc.; or
b. Any failure of a pumping station or treatment facility resulting in a bypass directly to receiving
waters without treatment of all or any portion of the influent to such station or facility.
Persons reporting such occurrences by telephone shall also file a written report in letter form within
five (5) days following first knowledge of the occurrence. This report must outline the actions taken
or proposed to be taken to ensure that the problem does not recur.
IV. INSPECTIONS
Adequate inspection, maintenance, and cleaning shall be provided by the Permittee to insure proper
operation of the subject facilities.
2. Any duly authorized officer, employee, or representative of the Division may, upon presentation of
credentials, enter and inspect any property, premises or place on or related to the disposal site or
facility at any reasonable time for the purpose of determining compliance with this permit, may
inspect or copy any records that must be maintained under the terms and conditions of this permit,
and may obtain samples of groundwater, surface water, or leachate.
4
V. GENERAL CONDITIONS
This permit shall become void unless the facilities are constructed in accordance with the conditions
of this permit, the approved plans and specifications, and other supporting data.
This permit is effective only with respect to the nature and volume of wastes described in the
application and other supporting data.
This permit is not transferable. In the event there is a desire for the facilities to change ownership, or
there is a name change of the Permittee, a formal permit request must be submitted to the Division
accompanied by documentation from the parties involved, and other supporting materials as may be
appropriate. The approval of this request will be considered on its merits and may or may not be
approved.
4. Upon the availability of a municipal or regional sewerage collection system, the subject wastewater
treatment facilities shall be abandoned and all wastewater discharged into the municipal or regional
sewerage system.
Failure to abide by the conditions and limitations contained in this permit may subject the Permittee
to an enforcement action by the Division in accordance with North Carolina General Statute 143-
215.6A to 143-215.6C.
6. The issuance of this permit does not exempt the Permittee from complying with any and all statutes,
rules, regulations, or ordinances which may be imposed by other government agencies (local, state,
and federal) which have jurisdiction, including but not limited to applicable river buffer rules in 15A
NCAC 2B.0200, erosion and sedimentation control requirements in 15A NCAC Chapter 4 and under
the Division's General Permit NCG010000, and any requirements pertaining to wetlands under 15A
NCAC 2B .0200 and 2H .0500.
7. This permit may be revoked if the Permittee fails to abide by the conditions of the "Operation and
Maintenance Agreement" previously signed by the Permittee.
A set of approved plans and specifications for the subject project must be retained by the Permittee
for the life of the project.
9. The annual administering and compliance fee must be paid by the Permittee within 30 days after
being billed by the Division. Failure to pay the fee accordingly may cause the Division to initiate
action to revoke this permit as specified by 15A NCAC 2H .0205 (c)(4).
10. The Permittee, at least six (6) months prior to the expiration of this permit, shall request its extension.
Upon receipt of the request, the Commission will review the adequacy of the facilities described
therein, and if warranted, will extend the Permit for such period of time and under such conditions
and limitations as it may deem appropriate.
Permit issued this the 18th day of June, 2002
lei
AL MANAGEMENT COMMISSION
i<Man W. Klimek, P.E., Director
Division of Water Quality
By Authority of the Environmental Management Commission
Peru Number WQ0020679
Permit No. WQ0020679
June 18, 2002
ENGINEER'S CERTIFICATION
Partial Final
1, , as a duly registered Professional Engineer in the State of North
Carolina, having been authorized to observe (periodically, weekly, full time) the construction of the project,
Project Name
Location and County
for the Permittee hereby state that, to the best of my abilities, due care and diligence was used in the observation of the
construction such that the construction was observed to be built within substantial compliance and intent of this permit,
the approved plans and specifications, and other supporting materials.
Signature
Date
Registration No.
I
O ~`+• _,f. ,1 ..— f/Iy,!' I�(i\,� .1 i', `I .,`�r `'.S.•.,; I �1�VLo
Y� 1Itircf!)/t.!•I)jV
�' .y r _i,iv 7 r 1!/r 11 1� - •U.
df1 r. '` F. !\�-- ` i11�i tC �• g •�\4 /,lJ {( 01
SllWS11f11,
r l,t • '.�„i ` y 1,``� S � `; � r��' S r'� � 'j� (r/ - `�'., �1`} _ � ..' •,i fl ( "1{ .-.l �\Xt � S �I , `V r.�,���� ' 'iti
1 Is�� o �� f S l-s d.�r �, , -. ; i �..,� , �' frl j I / �� . ( r - / ? if( Ill llll ((Iti- y J II ; i• lr:r-t�i �' +} - r y r l.�
��,� � -= , �-f�i�r � 1 (Ir II , ,•I Cm r—� - . `� � � ' '� �; • 'c(,_,��11'J,l�l =���� �r :�
I AI>,
,r „� ti�rr.l,(-, S � ^,��t.,�', '}1 i 'r"r �,v'a - ♦ i,, C_ ,l.'�`� �—fir �n
' ,l tl +"jir{I i ��' l ..Cm��• '_:y � r�e, -y S -7.� f 1 �I ��j �^���1 s(I
. r'- I(- ll{ l� � ' ��(, 1}•� 15- f... f �..\i , ,'4j 1 � 1 �.r 1/ r �.. _,` �` \ �jl �r I��} J� ., '� I�;�Jf�J � i'I It
^� ` 1'� _ ' `1 �, if , �` I' } }1,� I '1 r U {w a,� '°! 1\ _ _ l♦ III}11111._�' 1 r(l 'l llj ({a r �f �i
gIle,
3so
�---^ ; � J - 3_..-•r C-.: ' . ��,f Ji�� ,i I }! ��r- a m � � U. /`y' + ��` � iW -1- � 1J I7• ' � ilil ti,--�..�` t ..
J , J�)���t r�( ,� S' _�.,L I .�be i' --'rr -�.-�1(�'eo �� \ a :- .� "JI'_� ; ,�"• } � l��l, r t 1��� •'�rlf f`?� ! li{r lr
L _ `� _� n;• 1 •..rl •fit Jr,S ,�C , � 1 r _ '.�+•.�•' ', • • , • ( ' � ;z+ ': , ° 1r:'��•. (l(i )5 j+; 1
i-i1
} ` �� i{' u \ -. -�•� 1 ' I ^ t� u ' r 1„� i(; f' ; I` I \Ql(L-
�• -il _`1, ;` r / L .. `�.� 1, •_� , i I.u, l �� y� .!&�'c r!
O �Il\_ � 'f �..�` � `. tb ,(1' � 7� '`��'� I"_• '�. \ } !� ``_1.�'I� -;p��r ` It�,tl1% } �' I J 1}1; r �'•.
M (�1 rl /' •,• S ,. '\cam I ,"�, I , Y� ! U _
� ',`\, 4l if f tl`, �^' rp �IC� •..�.�,...�--...>v� , �. r T 1 _ � `���. �(,.._ - } if `� �/ � � � /jl�� {�
orl ! f .)� (r+ '} m ��� U "1L` ,� ll /Ir(_._•',4D l.
'`� _ � `.r-�-., -1��{ lll; �1��' . ' I . � O�� •}•�lo,. �a'��) /r{ `�r\�1�sq � � `� <<�( 1�11-- ' II��1� ,,,a '"1 ,
El e-•��f \. 1;�..fa e1r' 1 I�.,/ I� I� �'�.r "• ,I'` ;t �! S c J .�'- r �( If:
��. , a} � ..e, 1 ii �{(„ S �) 1 . , 5�.5::�l( �•4 ( �,y � �.r.�•'�: '. fjl.
o'�
Il
pJiJ r r%•J o It r ?//
�(:. ' ` rl. '1`C�`'- �. ,--1-•'�^ 1�.� l�',�-�r).•
q.
a y,`I I , yY ,• ��<�� j ; `:lll 'tiF !:, �\,t � �.' -_ �� Y;�.• .,• 1i + � ',_ - ,'1 j �� �� �'� ' ' I �•
0 � - � 5 rm4�•, ' � � 1 )� II ,1 �i 'rC //I'� � � •�7 1 _ i �' 1'•• = 1. 1 I ,. ( ii ' 1 y '° I ,�
(n �' � � \ ♦}�) i "f•e'- , ��h� � l�f,' - I -•„ �;\j r r r� 1_=. i! •.• � �. }�� I. � l �� 1 f �".�('!,'g+ r ' �1,.
LU
�> i y // m m P � f a - -_s I � l ' .- /� J 7 : ♦�-� t1� 5 "' 6.4 ftf.`','
Z ���.----,L y`i� li 1� i r f�J�„`1 �i• .r '•� (, t- , r��� � •I�;l� � ! •'' •U��'�,1� I '?� f ��, �j'r .
0 1 H I ,, `• /—_��/f , 11ti -`�_� ;c l .=rf- �"-�'• ' �.i' I J 7 C��
a O �l. j �,/' ) _��� Jl -=a I \ L _. ,;.�. %'' j_'il•:.�I.: ,: �7 I ) 1'..� _
y_)
v Q .¢ � . �41�( ,f - -,t r `,I II • � �._; (� ' y '�. / �: ;' j { ��L�'( i - •: '��`'�� - ---- - -.+ -- ��r -- __ �
r'� yOj(r;l• ,, ' C`l)- ;/ �I ', /'_ �, _,� <I!�_� }.[ I��".11`....� '//[�l `qs, f" �@,• 'L. ••r...i'��•., „i ��rJ. (;` tX
i"" ? }- l _� " - � ) r�l S �'•' t { y J .' i U _ _ - ,1 -1 1 � �. -\ _ �"✓� f ! _ -n? 4� • I r'' 1� \\\ f �..
L1:'co :�' �• 11 i� t r, �� rf, mm ��• ��—.� � ��� ` l� w���y`. i� f �f. �' ���
O O ', c - I �" • ,} ..I ;
� _ '} j. ,� r fl s �fl !} `$\t �� 4 ��.'�;
0 l-•. � Ol`_ - � -�I 7� n��`,'/, �•+14 'r' ��f��,/`�. � gp= ..�_
O S 1 } '�' 4k, •l%�.{ • . ��;1y.-� r � ?� .� -•11. ii• i�<�� I " • �
w Z W �. �,:--'� -- I�•,//.,•• , •C'3 iy �'1 < < ;� i ••— II �.r ,• _ +r 1 �rsy
�— Li out
O LL' J '� �♦,-♦ .��a.`�' r ,�Oii`r. I (_t`{` ., I .�/o� r,1 � � ' �•. I
1_,'J�1` m ! .�� r y `�i.f .., - '_ 1_., J`:� ,,m ill,�� .: � m=��\j� ,�• .. :,, �i _.!- `'(• • r % r.
OPERATION AND MAINTENANCE AGREEMENT
SINGLE FAMILY RESIDENCE WASTEWATER TREATMENT SYSTEM
DIVISION OF WATER QUALITY
Mr. Steven C. Biggs
1414 Stallings Road
Durham, NC 27703
,Disposal Method; SP�YLRMGA-nO DRIP "IRRIGATION
(Circle One) e)
County: I�ua)y Permit No
I agree to operate and maintain the wastewater treatment system as follows:
1) The Permittee is responsible for the operation and maintenance of the entire treatment and disposal system
including, but not limited to, the following items:
a) The septic tank shall be checked annually and pumped out as needed. The effluent filter shall be checked
and cleaned at the same frequency of the septic tank.
b) Check one:
► The tablet chlorinator shall be checked every week. Tablets shall be added so as to provide proper
chlorination.
► The ultraviolet disinfection unit shall be checked every week. The lamp shall be cleaned and/or
replaced to ensure proper disinfection.
c) The storage, pump, and alarm systems shall be inspected monthly. The scum layer shall be removed at the
same time interval as the septic tank is pumped out.
d) The irrigation system shall be inspected monthly to make certain of proper operation, that vegetative
growth does not interfere with the system inspection or operation, that the soil is assimilating the disposed
treated wastewater with no surface runoff, and that no objectionable odors are being generated.
2) Failure of the Permittee to properly operate this system is subject to a penalty up to $25,000 per day.
3) Failure to meet the permit conditions or violation of the State's surface or groundwater regulations will require
evacuating the dwelling and may void the permit.
I understand the above requirements and agree to these terms as part of the issued permit.
Signatur . Date: _Z� �
Ste en C Biggs
Notary Seal
Notary Signature- _ y Comrriission Expires:_ILZ5 .2063
WATER POLLUTION CONTROL SYSTEM OPERATORS
CERTIFICATION COMMISSION
CLASSIFICATION
RATING SHEET FOR WATER POLLUTION CONTROL SYSTEMS
FACILITY INFORMATION:
NAME OF FACILITY: Steven C. Biggs
MAILING ADDRESS: 1414 Stallings Rd., Durham, NC 27703
COUNTY: Durham
CONTACT PERSON: Steven C. Bugs TELEPHONE:
PERMIT NO.: WQ0020679 Check One: NC WQ ✓ HEALTH DP
ORC: TELEPHONE:
RATING INFORMATION: (Before completing this section, please refer to pages 2-4)
PERMITTED FLOW: 360 GPD BNR? YES NO
CHECK CLASSIFICATION: WASTEWATER: 1 2 3 4
COLLECTION: 1 2 3 4
SPRAY IRRIGATION ✓ SUBSURFACE LAND APPLICATION
PHYSICAL/CHE AL GRADE I GRADE If
RATED BY: Ran XJ�s REGION: RRO DATE: 5/7/02
REGIONAL OFFICE TELEPHONE NUMBER: 919/571-4700 EXT: 249
Page 1
Permit No.: WQ0020679
Classification of Spray Irrigation Water Pollution Control Systems:
✓ Systems which utilize spray irrigation for the reuse or disposal of wastewater.
These systems include: septic tanks, sand filter, oil/water separators, lagoons,
storage basins, screening, sedimentation. Systems other than those listed above
shall be subject to additional classification.
Classification of Land Application of Residuals Systems:
Systems permitted and dedicated for the land application of residuals that are produced by
a water pollution control system or contaminated soils.
Classification of Pbysical/Chemical Water Pollution Control Treatment Systems:
Grade I Physical/Chemical: Any water pollution control system that utilizes a primarily
physical process to treat wastewater. This classification includes groundwater remediation
systems **
Grade II Physical/Chemical: Any water pollution control system that utilizes a primarily
chemical process to treat wastewater. This classification includes reverse osmosis,
electrodialysis, and ultrafiltration systems. **
** Any water pollution control system that utilizes a physical/chemical process to enhance an
activated sludge or fixed growth process, shall not be subject to additional classification
.................................................................................................................................................................
Classification of Subsurface Water Pollution Control Systems:
Systems which utilize the soil for subsurface treatment and disposal of wastewater
And/or are required to have a certified operator under 15A NC.AAC 18A.1961. ***
*** Any subsurface system that has as part of its treatment process a water pollution control
system that may be classified under Rules .0302 through .0307 of this section shall be
subject to additional classification.
Page 3
Permit No.: WQ0020679