HomeMy WebLinkAboutWQ0019188_Final Permit_20001220State of North Carolina
Department of Environment
and Natural Resources
Division of Water Quality
James B. Hunt, Jr., Governor
Bill Holman, Secretary
Kerr T. Stevens, Director
December 20, 2000
Patrick ONeal
Chatham Development Corporation .
211 Chancellor Ridge Drive
Durham, N. C. 27713
I T kTW1N;WA 10 •
NCDENR
NORTH CAROLINA DEPARTMENT OF
ENVIRONMENT AND NATURAL RESOURCES
Subject: Permit No. WQ0019188
Chatham Development Corp.
Thompson Creek Subdivision — Lot #21
Drip Irrigation Facility
Chatham County
Dear Mr. O'Neal:
In accordance with your request received October 24, 2000, we are forwarding herewith Permit No.
WQ0019188, dated December 20, 2000, to Chatham Development Corporation for the continued operation of the
subject single family wastewater treatment and drip irrigation facilities.
6/wuwddrkC'
This permit shall be effective from the date of issuance until, 2005, and shall be subject to the
conditions and limitations as specified therein. Please pay particular attention to the monitoring requirements in
this permit. Failure to establish an adequate system for collecting and maintaining the required operational
information will result in future compliance problems. Upon completion of the transfer of the property to another
party, a name change request shall be submitted to the Division of Water Quality accompanied by an application
fee, documentation from the parties involved, and other supporting materials as may be appropriate,
If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to
request an adjudicatory hearing upon written request within thirty (30) days following receipt of this permit_ This
request must be in the form of a written petition, conforming to Chapter 150$ of the North Carolina General
Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, NC 27699-6714.
Unless such demands are made this permit shall be final and binding.
One set of approved plans and specifications is being forwarded toy . If you need additional information
concerning this matter, please contact Susan Cauley at (919) 733-5083 exteon 546.
Since i
-Kerr T. Stevens
cc: Chatham County Health Department
Raleigh Regional Office, Water Quality Section
.Terry Dalton, P.E., Dalton Engineering and Associates
Technical Assistance and Certification Unit
Non -Discharge Compliance/Enforcement Unit
1617 Mail Service Center, Raleigh, North Carolina 27699-1617 Telephone (919) 733-5083 Fax (919) 715-6048
An Equal Opportunity Affirmative Action Employer 50% recycled/10% post -consumer paper
NORTH CAROLINA
ENVIRONMENTAL MANAGEMENT COMMISSION
DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES
RALEIGH
SINGLE FAMILY DRIP IRRIGATION PERMIT
In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as
amended, and other applicable Laws, Rules, and Regulations
PERMISSION IS HEREBY GRANTED TO
Chatham Development Corporation
Chatham County
FOR THE
construction and operation of a 480 GPD drip irrigation wastewater treatment and disposal system consisting
of a 1,340 gallon baffled septic tank, two 60 square feet recirculating sand filter, a 20 gpm ultraviolet
disinfection unit, a 3,000 gallon storage/pump tank, a 20 GPM pump and a 13,656 square feet drip irrigation
area with 2,276 enutters to serve Thompson Creek Subdivision — Lot #21, with no discharge of wastes to the
surface waters, pursuant to the application received October 24, 2000, and in conformity with the project plan,
specifications, and other supporting data subsequently filed and approved by the Department of Environment
and Natural Resources and considered a part of this permit.
This permit shall be effective from the date of issuance until November 30, 2005, and shall be subject to
the following specified conditions and limitations:
I. PERFORMANCE STANDARDS
Upon completion of construction and prior to operation of this permitted facility, a certification
must be received from a professional engineer certifying that the permitted facility has been
installed in accordance with this permit, the approved plans and specifications, and other
supporting materials. If this project is to be completed in phases and partially certified, you shall
retain the responsibility to track further construction approved under the same permit, and shall
provide a final.. certificate of completion once the entire proiect has been completed. Mail the
Certification to the Non -Discharge Permitting Unit, 1617 Mail Service Center, Raleigh, NC
27699-1617.
2. The Raleigh Regional Office, telephone number (919) 571-4700, shall be notified at least forty-
eight (48) hours in advance of operation of the installed facilities so that an in-place inspection can
be made. Such notification to the regional supervisor shall be made during the normal office
hours from 8:00 a.m. until 5:00 p.m. on Monday through Friday, excluding State Holidays.
The drip irrigation facilities shall be effectively maintained and operated at all times so that there
is no discharge to the surface waters, nor any contamination of ground waters which will render
them unsatisfactory for normal use. In the event that the facilities fail to perform satisfactorily,
including the creation of nuisance conditions or failure of the irrigation area to adequately
assimilate the wastewater, the Permittee shall take immediate corrective actions including those
actions that may be required by the Division of Water Quality (Division), such as the construction
of additional or replacement wastewater treatment and disposal facilities.
4. The issuance of this permit shall not relieve the Permittee of the responsibility for damages to
surface or groundwaters resulting from the operation of this facility.
The sand media of the recirculating sand- filter must comply with the Division's sand
specifications. The engineer's certification will serve as evidence that these specifications have
been met.
6. A leakage test shall be perforined'on the septic tank and dosing tank to insure that any exfiltration
occurs at a rate which does not exceed twenty (20) gallons per twenty-four (24) hours per 1,000
gallons of tank capacity. The engineer's certification will serve as proof of compliance with this
condition.
7. If excavation into bedrock is required for the installation of the septic tank or sand filter, the pit
shall be lined with a 10 mil synthetic liner.
8. A sanitary tee shall be installed on the effluent pipe of the septic tank. The engineer's certification
will serve as evidence that these specifications have been met.
The residuals generated from these treatment facilities must be disposed in accordance with
General Statute 143-215.1 and in a manner approved by the Division.
10. Diversion or bypassing of the untreated wastewater from the treatment facilities is prohibited.
1 1. The following buffers shall be maintained:
a) 100 feet between wetted area and any residence or places of public assembly under separate
ownership,
b) 50 feet between wetted area and property lines,
c) 100 feet between wetted area and wells,
d) 50 feet between wetted area and drainageways or surface water bodies,
e) 50 feet between wetted area and public right of ways,
f) 100 feet between treatment/storage units and any wells, and
g) 50 feet between treatment units and property lines.
It. OPERATION AND MAINTENANCE REQUIREMENTS
The facilities shall be properly maintained and operated at all times.
2. Upon classification of the facility by the Water Pollution Control System Operators Certification
Commission (WPCSOCC), the Permittee shall employ a certified wastewater treatment plant
operator to be in responsible charge (ORC) of the wastewater treatment facilities. The operator
must hold a certificate of the type and grade at least equivalent to or greater than the classification
assigned to the wastewater treatment facilities by the WPCSOCC. The Permittee must also
employ a certified back-up operator of the appropriate type and grade to comply with the
conditions of 15A NCAC 8G .0202. The ORC of the facility must visit each CIass I facility at
least weekly and each Class II, III, and IV facility at least daily, excluding weekends and holidays,
and must properly manage and document daily operation and maintenance of the facility and must
comply with all other conditions of 15A NCAC 8G .0202. Once the facility is classified, the
Permittee must submit a letter to the WPCSOCC which designates the operator in responsible
charge within thirty days after the wastewater treatment facilities are 50% complete.
3. A suitable year round vegetative cover shall be maintained.
4. Irrigation shall not be performed during inclement weather or when the ground is in a condition
that will cause runoff.
5. Adequate measures shall be taken to prevent wastewater runoff from the drip field.
6. The application rate shall not exceed a cumulative loading of 21.85 inches over any twelve (12)
month period at an instantaneous application rate not to exceed 0.24 inches per hour.
7. The facilities shall be effectively maintained and operated as a non -discharge system to prevent
the discharge of any wastewater resulting from the operation of this facility.
8. No type of wastewater other than that from the Thompson Creek Subdivision - Lot 421 shall be
dripped onto the irrigation area.
9. No traffic or equipment shall be allowed on the disposal area except while installation occurs or
while normal maintenance is being performed.
10. The drip irrigation field shall be fenced with at least a two strand wire fence.
11. The Permittee is responsible for the operation and maintenance of the entire treatment and
disposal system including, but not limited to, the following items:
a. The septic tank shall be checked annually and pumped out as needed.
b. The ultraviolet disinfection unit shall be checked every week. The lamp shall be cleaned
and/or replaced to ensure proper disinfection.
c. The storage, pump, and alarm systems shall be inspected weekly. The scum layer shall be
removed at the same interval as the septic tank is cleaned out.
d. The drip irrigation system shall be inspected monthly to make certain of proper operation, that
the vegetative growth allows a proper irrigation patterns, that the soil is assimilating the
disposed treated wastewater with no surface runoff, and that no objectionable odors are being
generated.
ffi. MONITORING AND REPORTING REQUIREMENTS
1. Any monitoring deemed necessary by the Division to insure surface and ground water protection
will be established and an acceptable sampling reporting schedule shall be followed.
2. The Permittee shall maintain records of all maintenance performed on the system and irrigation
area, as required in Condition 1I 12 for a minimum of five years. This information shall be
provided to the Division upon request.
3. Noncompliance Notification:
The Permittee shall report by telephone to the Raleigh Regional Office, telephone number (919)
571-4700, as soon as possible, but in no case more than 24 hours or on the next working day
following the occurrence or first knowledge of the occurrence of any of the following:
a. Any process unit failure, due to known or unknown reasons, that renders the facility incapable
of adequate wastewater treatment, such as mechanical or electrical failures of pumps, emitters,
etc.; or
3
b. Any failure of a pumping station or treatment facility resulting in a by-pass directly to
receiving waters without treatment of all or any portion of the influent to such station or
facility.
Persons reporting such occurrences by telephone shall also file a written report in letter form
within five (5) days following first knowledge of the occurrence. This report must outline the
actions taken or proposed to be taken to ensure that the problem does not recur.
TV. INSPECTIONS
1. Adequate inspection, maintenance, and cleaning shall be provided by the Permittee to insure
proper operation of the subject facilities.
2. Any duly authorized officer, employee, or representative of the Division may, upon presentation
of credentials, enter and inspect any property, premises or place on or related to the disposal site or
facility at any reasonable time for the purpose of determining compliance with this permit, may
inspect or copy any records that must be maintained under the terms and conditions of this permit,
and may obtain samples of groundwater, surface water, or leachate.
V. GENERAL CONDITIONS
1. This permit shall become voidable unless the facilities are constructed in accordance with the
conditions of this permit, the approved plans and specifications, and other supporting data.
2. This permit is effective only with respect to the nature and volume of wastes described in the
application and other supporting data.
3. This permit is not transferable_ In the event there is a desire for the facilities to change ownership,
or there is a name change of the Permittee, a formai permit request must be submitted to the
Division accompanied by an application fee, documentation from the parties involved, and other
supporting materials as may be appropriate. The approval of this request will be considered on its
merits and may or may not be approved.
4. Upon the availability of a municipal or regional sewerage collection system, the subject
wastewater treatment facilities shall be abandoned and all wastewater discharged into the
municipal or regional sewerage system.
5. Failure to abide by the conditions and limitations contained in this permit may subject the
Permittee to an enforcement action by the Division in accordance with North Carolina General
Statute 143-215.6A to 143-215.60.
6. The issuance of this permit does not preclude the Permittee from complying with any and all
statutes, rules, regulations, or ordinances which may be imposed by other government agencies
(local, state, and federal) which have jurisdiction.
7. This permit may be revoked if the Permittee fails to abide by the conditions of the "Operation and
Maintenance Agreement" previously signed by the Permittee.
8. A set of approved plans and specifications for the subject project must be retained by the
Permittee for the life of the project.
9. The annual administering and compliance fee must be paid by the Permittee within 30 days after
being billed by the Division. Failure to pay the fee accordingly may cause the Division to initiate
action to revoke this permit as specified by 15A NCAC 2H.0205 (c)(4)_
4
10. The Permittee, at least six (6) months prior to the expiration of this permit, shall request its
extension. Upon receipt of the request, the Commission will review the adequacy of the facilities
described therein, and if warranted, will extend the Permit for such period of time and under such
conditions and limitations as it may deem appropriate.
Permit issued this tf 120th day of December, 2000.
NORTH,CA4tOLINA E,pWIFOL4MENTAL MANAGEMENT COMMISSION -
Kerr T. Stevens, Director
Division of Water Quality
By Authority of the Environmental Management Commission
Permit Number WQ0019188
Permit No. WQ0019188
December 20, 2000
ENGINEER'S CER'T'IFICATION
Partial Final J
I, , as a duly registered Professional Engineer in the State of North
Carolina, having been authorized to observt-(periodically, weekly, full time) the construction of the project,
Project Name Location and County
for the Permittee hereby state that, to the best of my abilities, due care and diligence was used in the observation of
the construction such that the construction was observed to be built within substantial compliance and intent of this
permit, the approved plans and specifications, and other supporting materials.
Signature Registration No
Date
OPERATION AND MAINTENANCE AGREEMENT FOR THEa
DIVISION OF ENVIRONMENTAL MANAGEMENT
Re 57 FIRM MJ
Address: ---
City: 1A. y, State:
Single Family Residence Wastewater Treatment System
Final Disposal by Spray Irrigation
Pennit No.
ZiP: Z-7 `7 13
' County
I agree to operate and maintain the wastewater treatment system as follows:
1. The Permittee is responsible for the operation and maintenance of the entire treatment and
disposal systr . including, but not limited to, the following items:
a. The septic tank shall be checked every six (6) months and pumped out as rewired..
b. The tablet chlonrator shall be checked every week until the actual usage rate is established
and thence or. a monthly basis. Tablets shall be added so as to provide proper chlorination.
R•
c. The storage system, pump system, and alarm system shall be inspected monthly. The
scum layer shat be. removed at the same interval as the septic tank is cleaned out.
d. The spray system shall be inspected monthly to make certain of the sprayers proper
operation, that the vegetative growth allows proper spray patterns, that the soil is absorbing
the disposed treated wastewater with no surface runoff, and that no objectionable odors arc
being generated.
2. Failure of the Permittee to properly operate this system is subject to a penalty up to $ID,ODO per
day.
3. Failure to meet permit conditions or violation of the State's surface or groundwater regulations
will require cessation of occupancy of the residence.
I understand that ure to compl these conditions along with the permit conditions may result in
voiding the permiLA
Signature:
Notary Seal
No {nature: ,fin `�.
"' Al^v ; M
L
. PUBLIC
Date: / �" Z `//'/10