Loading...
HomeMy WebLinkAboutWQ0016500_Final Permit_19991101State of North Carolina Department of Environment and Natural Resources Division of Water Quality James B. Hunt, Jr., Governor Bill Holman, Secretary Kerr T. Stevens, Director November 1, 1999 Mr. Arthur Purvis, President Purvis Land & Timber, L.L.C. 700 Putnam Church Road Carthage, North Carolina 28327 `0 NCDENR NORTH CAROLINA DEPARTMENT OF ENVIRONMENT ANC NATURAL REsOURCEs Subject: Permit No. WQ0016500 Purvis Land & Timber, L.L.C. — Lot No. 8 Single -Family Wastewater Spray Irrigation Facility Chatham County Dear Mr. Purvis: In accordance with your application received February 23, 1999 as well as the additional information received on July 8, 1999, September 7, 1999, and October 27, 1999, we are forwarding herewith Permit No. WQ0016500, dated November 1, 1999, to Purvis Land & Timber, L.L.C. for the construction and operation of the subject single-family wastewater treatment and spray irrigation facilities. Please pay particular to Condition I. 12., which stipulates the property transfer requirements for the subject property. Note that permanent language must be added to the deed to reflect the fact that the design of the facility is such that the State -required buffer between the wetted area and property lines, as stipulated in 15A NCAC 2H .0219 0)(5)(i), could not be maintained with and by adjoining lots. This condition provides that lot -specific information regarding the conveyance and receipt of buffer waivers also be added to the deed language. Also be aware that a formal request Tor reissuance of this permit is necessary to transfer ownership of the facilities permitted herein. Condition V. 3. Details these requirements, and stipulates that "a copy of this permit, all approved plans and specifications, final record drawings, as well as all operation and maintenance information and lag books shall be conveyed to the new owner at the time of closing[,]" if the facilities are to change ownership. Condition V. 4. requires that the design engineer provide comprehensive information regarding operation and maintenance of the permitted facilities prior to wastewater being made tributary to familiarize the Permittee with the operating and monitoring requirements stipulated by this permit. Failure to establish an adequate system for collecting and maintaining the required operational information will result in future compliance problems. This permit shall be effective from the date of issuance until October 31, 2004 and shall be subject to the conditions and limitations as specified therein. If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within 30 days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 150B of the North Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, NC 27699-6714 Unless such demands are made, this permit shall be final and binding. 1617 Mail Service Center, Raleigh, North Carolina 27699-1617 Telephone (919) 733-5083 Fax (919) 715-6048 An Equal Opportunity Affirmative Action Employer 50% recycled/10% post -consumer paper One set of approved plans and specifications is being forwarded to you. If you need additional information concerning this matter, please contact tW IOaER5,,..o at (919) 733-5083, exte sion 533. Sincer , i ,Kerr T. Stevens cc: Chatham County Health Department Michael S. Koonce, P.E. Raleigh Regional Office, Water Quality Section Technical Assistance and Certification Unit Non -Discharge Compliance/Enforcement Unit NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES RALEIGH SINGLE-FAMILY ,SPRAY IRRIGATION PERMIT In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations PERMISSION IS HEREBY GRANTED TO Purvis Land & Timber, L.L.C. Chatham County FOR THE construction and operation of a 480-GPD spray irrigation wastewater treatment and disposal system consisting of a 1,200-gallon baffled septic tank with effluent filter; a distribution box followed by one 420.5-square foot gravity - dosed sub -surface sand filter; a tablet chlorinator; one 3,000-gallon storage/pump tank (with floats set to provide a minimum net storage volume of 2,400 gallons); a 43-GPM pump with a high-water alarm light and buzzer and an automatic rain shut-off device; a 19,444.93-square foot spray irrigation area with six full -circle, overlapping (set 46 feet on center), 7 8-foot diameter, 5.5-GPM sprinkler heads; and all associated piping, valves, and appurtenances to serve the four -bedroom residence to be built on Lot No. 8 of Purvis Land & Timber L.L.C.'s property (Deed Book 756, Page 953) located in Hadley Township near the intersection of Timber Ridge Road (NCSR 1547) and Lutterloh Road (NCSR 1548) at latitude coordinate 35°48'08" and longitude coordinate 79°14'06", with no discharge of wastes to the surface waters, pursuant to the application received February 23, 1999, and in conformity with the project plans, specifications, and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources and considered a part of this permit. This permit shall be effective from the date of issuance until October 31, 2004 and shall be subject to the following specified conditions and Iimitations: 1. PERFORMANCE STANDARDS Upon completion of construction and prior to operation of this permitted facility, a certification must be received from a professional engineer certifying that the permitted facility has been installed in accordance with this permit, the approved plans and specifications, and other supporting materials. If this project is to be completed in phases and partially certified, you shall retain the responsibility to track_ further construction approved under the same permit, and shall provide a final certificate of completion once the entire project has been completed. Mail the Certification to the Non -Discharge Permitting Unit, 1617 Mail Service Center, Raleigh, NC 27699-1617. 2. The Raleigh Regional Office, telephone number (919) 571-4700, shall be notified at least 48 hours in advance of operation of the installed facilities so that an in -place inspection can be made. Such notification to the regional supervisor shall be made during the normal office hours from 8:00 a.m. until 5:00 p-m. on Monday through Friday, excluding State Holidays. 3. The spray irrigation facilities shall be effectively maintained and operated at all times so that there is no discharge to the surface waters, nor any contamination of ground waters which will render them unsatisfactory for normal use. In the event that the facilities fail to perform satisfactorily, including the creation of nuisance conditions or failure of the irrigation area to adequately assimilate the wastewater,. the Permittee shall take immediate corrective actions including those actions that may be required by the Division of Water Quality (Division), such as the construction of additional or replacement wastewater treatment and disposal facilities. 4. The issuance of this permit shall not relieve the Permittee of the responsibility for damages to surface or groundwaters resulting from the operation of this facility. The sand media of the sub -surface sand filters must comply with the Division's sand specifications. The engineer's certification will serve as evidence that these specifications have been met. 6. A leakage test shall be performed on the septic tank and dosing tank to insure that any exfiltration occurs at a rate which does not exceed 20 gallons per 24 hours per 1,000 gallons of tank capacity. The engineer's certification will serve as proof of compliance with this condition. 7. If excavation into bedrock is required for the installation of the septic tank, storage/pump tanks, or sand filters, the pit shall be lined with a 10-mil synthetic liner. A sanitary tee and appropriately -sized effluent filter shall be installed on the effluent pipe of the septic tank. The engineer's certification will serve as evidence that these specifications have been met. 9. The residuals generated from these treatment facilities must be disposed in accordance with General Statute 143-215.1 and in a manner approved by the Division. 10. Diversion or bypassing of the untreated wastewater from the treatment facilities is prohibited. 11. The following buffers shall be maintained: a) 400 feet between wetted area and any residence or places of public assembly under separate ownership, b) 150 feet between wetted area and property lines (see Condition 1. 12. herein), c) 100 feet between wetted area and wells, d) 100 feet between wetted area and drainageways or surface water bodies, e) 50 feet between wetted area and public right of ways, f) 100 feet between treatment/storage units and any wells, and g) 50 feet between treatment units and property lines. 12. Buffers to the property line on the subject property are affected by the wetted areas of the spray irrigation facilities proposed for Lot No. 7 ofPurvis Land & Timber, L.L.C.'s property permitted under Permit No. Permit No. WQ0016499. In addition, the wetted area of the spray irrigation facility for the subject property affects a buffer to the property Iines of Lot No. 6 and Lot No. 7 of Purvis Land & Timber, L.L.C.'s property permitted under Permit No. WQ0016498 and Permit No. WQ0016499, respectively, as well as a property owned by Edna Webster (Deed Book 483, Page 601). A buffer waiver for the Edna Webster property has been filed in Deed Book 787, Page 19 on July 6, 1999 by the Chatham County Register of Deeds. Also, the Permittee shall add the following language to the deed to be drafted for the subject property upon its conveyance: "[i]t is acknowledged by the Grantor and Grantee that the above described lot(s) has a wastewater spray irrigation system which is to be installed at a distance from the property lines that is less than the State -required minimum buffer of 150 feet as stipulated in 15A NCAC 2H .0219' 0)(5)(i), and the Grantee accepts this systems `As Is,' and that the adjoining lot(s) may also have less than the State -required minimum buffer of 150 feet." Information regarding the lots to which the subject property has conveyed buffer waivers and from which the subject has received buffer waivers shall be made a permanent part of the deed Ianguage as well. II. OPERATION AND MAINTENANCE REQUIREMENTS 1. The facilities shall be properly maintained and operated at all times. 2. Upon classification of the facility by the Water Pollution Control System Operators Certification Commission (WPCSOCC), the Permittee shall employ a certified wastewater treatment plant operator to be in responsible charge (ORC) of the wastewater treatment facilities. The operator must hold a certificate of the type and grade at least equivalent to or greater than the classification assigned to the wastewater treatment facilities by the WPCSOCC. The Permittee must also employ a certified back-up operator of the appropriate type and grade to comply with the conditions of 1 SA NCAC 8G .0202. The ORC of the facility must visit each Class I facility at least weekly and each Class II,111, and IV facility at least daily, excluding weekends and holidays, and must properly manage and document daily operation and maintenance of the facility and must comply with all other conditions of 15A NCAC 8G .0202. Once the facility is classified, the Permittee must submit a letter to the WPCSOCC which designates the operator in responsible charge within thirty days after the wastewater treatment facilities are 50% complete. 3. A year-round cover crop of pine trees shall be established on the spray irrigation field. Care shall be taken to preserve the integrity of the spray irrigation field during its preparation. All areas cleared as a result of installation area shall be appropriately seeded, fertilized, and mulched to establish an appropriate cover crop. 4. In the event that the sprinkler heads fail to achieve the design diameter of 78 feet due to obstructions, the obstructions shall be removed or the sprinkler heads shall be raised and supported to such height that the design diameter is achieved. Irrigation shall not be performed during inclement weather or when the ground is in a condition that will cause runoff. Adequate measures shall be taken to prevent wastewater runoff from the spray field. 6. The application rate shall not exceed a cumulative loading of 24.7 inches over any 12-month period at an instantaneous application rate not to exceed 0.20 inches per hour. The facilities shall be effectively maintained and operated as a non -discharge system to prevent the discharge of any wastewater resulting from the operation of this facility. No type of wastewater other than that from the four -bedroom residence to be built on Lot No. 8 of on Lot No. 8 of Purvis Land & Timber L.L.C.'s property (Deed Book 756, Page 953) located in Hadley Township near the intersection of Timber Ridge Road (NCSR 1547) and Lutterloh Road (NCSR 1548) at latitude coordinate 35°48'08" and longitude coordinate 79°14'06" shall be sprayed onto the irrigation area. 9. No traffic or equipment shall be allowed on the disposal area except while installation occurs or while normal maintenance is being performed. 10. The spray irriZn gation field shall be fenced with at least a two -strand wire fence. 11. The Permittee is responsible for the operation and maintenance of the entire treatment and disposal system including, but not limited to, the following items: 3 a. The septic tank shall be checked annually and pumped out as needed. The effluent filter shall be checked and cleaned at the same frequency as the septic tank. b. The tablet chlorinator shall be checked every week. Tablets shall be added so as to provide proper chlorination. c. The storage, pump, and alarm systems shall be inspected weekly. The scum layer shall be removed at the same interval as the septic tank is cleaned out. d. The spray system shall be inspected weekly to make certain of the sprayers' proper operation, that the vegetative growth allows a proper spray pattern, that the soil is assimilating the disposed treated wastewater with no surface runoff, and that no objectionable odors are being generated. III. MONITORING AND REPORTING REQUIREMENTS Any monitoring deemed necessary by the Division to ensure surface and ground water protection will be established and an acceptable sampling reporting schedule shall be followed. 2. The Permittee shall maintain records of all maintenance performed on the system and irrigation area, as required in Condition H. 12. for a minimum of five years. This information shall be provided to the Division upon request. 3. Noncompliance Notification: The Permittee shall report by telephone to the Raleigh Regional Office, telephone number (919) 571- 4700, as soon as possible, but in no case more than 24 hours or on the next working day following the occurrence or first knowledge of the occurrence of any of the following; a. Any process unit failure, due to known or unknown reasons, that renders the facility incapable of adequate wastewater treatment, such as mechanical or electrical failures of pumps, spray heads, etc.; or b. Any failure of a pumping station or treatment facility resulting in a by-pass directly to receiving waters without treatment of all or any portion of the influent to such station or facility. Persons reporting such occurrences by telephone shall also file a written report in letterform within five days following first knowledge of the occurrence. This report must outline the actions taken or proposed to be taken to ensure that the problem does not recur. IV. INSPECTIONS 1. Adequate inspection, maintenance, and cleaning shall be provided by the Permittee to ensure proper operation of the subject facilities. 2. Any duly authorized officer, employee, or representative of the Division may, upon presentation of credentials, enter and inspect any property, premises or place on or related to the disposal site or facility at any reasonable time for the purpose of determining compliance with this permit, may inspect or copy any records that must be maintained under the terms and conditions of this permit, and may obtain samples of groundwater, surface water, or leachate. V. GENERAL CONDITIONS This permit shall become voidable unless the facilities are constructed in accordance with the conditions of this permit, the approved plans and specifications, and other supporting data. 2. This permit is effective only with respect to the nature and volume of wastes described in the application and other supporting data. 4 3. This permit is not transferable. In the event there is a desire for the facilities to change ownership, or there is a naive change of the Permittee, a formal permit request must be submitted to the Division accompanied by an application fee, documentation from the parties involved, and other supporting materials, including a revised "Operation and Maintenance Agreement" and the property deed for the subject property, as may be appropriate_ The approval of this request will be considered on its merits and may or may not be approved. Note that, if the subject facilities are to change ownership, a copy of this permit, all approved plans and specifications, final record drawings, as well as all operation and maintenance information and Iog books shall be conveyed to the new owner at the time of closing. 4. No flow shall be made tributary to the facilities permitted herein until the design engineer has provided the Permittee with a comprehensive description of the treatment and disposal system as well as a guide for both its operation and maintenance. 5. Upon the availability of a municipal or regional sewerage collection system, the subject wastewater treatment facilities shall be abandoned and all wastewater discharged into the municipal or regional sewerage system. 6. - Failure to abide by the conditions and limitations contained in this permit may subject the Permittee to an enforcement action by the Division in accordance with North Carolina General Statute 143-215.6A to 143-215.6C. 7. The issuance of this permit does not preclude the Permittee from complying with any and all statutes, rules, regulations, or ordinances which may be imposed by other government agencies (local, state, and federal) which have jurisdiction. 8. This permit may be revoked if the Permittee fails to abide by the conditions of the "Operation and Maintenance Agreement" previously signed by the Permittee. 9. The annual administering and compliance fee must be paid by thePermittee within 30 dyas after being billed by the Division. Failure to pay the fee accordingly may cause the Division to initiate action to revoke this permit as specified by 15A NCAC 2H .0205 (c)(4). 10. A set of approved plans and specifications for the subject project as well as any as -built drawings must be retained by the Permittee for the life of the project. 11. The Permittee, at least six months prior to the expiration of this permit, shall request its extension. Upon receipt of the request, the Division will review the adequacy of the facilities described therein, and if warranted, will extend the Permit for such period of time and under such conditions and limitations as it may deem appropriate. Permit issued this c first day of November, 1999 NORTH AROLINA E VIRONMENTAL MANAGEMENT COMMISSION ,/—Kerr T. Stevens, Director Division of Water Quality By Authority of the Environmental Management Commission Permit Number WQ0016500 Permit No. WQ0016500 November 1, 1999 ENGINEER'S CERTIFICATION Partial Final I, , as a duly registered Professional Engineer in the State of North. Carolina, having been authorized to observe (periodically, weekly, full time) the construction of the project, Project Name Location and County for the Permittee hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance and intent of this permit, the approved plans and specifications, and other supporting materials. Signature Date Registration No. ' l/ Y � - C�3 YN^� _aR — —�' •' .Q • r1�� �' i.i'. \ J r'Vr� GZ.L ' '�+��.�, _ ; I .• -. y.--._.�, �, a91.�r ; .r'..� ��• •�._, (! / 007 reds,_ 115' 17 l��P ),G, ! -$ha -r chapel � / � // 1' - '— ram• - � � � � � ,'' `1`'.:--�- � _ ' -77 494 4 7' 30'r 1 1 . ! ram' .-�•� �, A - -E w 3962 ,✓ \ _ -,Ili I11✓�� ' � � � � � =�- � 'r ��' �1• n � l �� �//'ter r�`J'. :/..s��.' r 5� .•` 3F �' f�.�� �-'. J `r I �.'GC" I1'�` �' _ wo ;;`J �i/11 � nso2 L' � �'r ' "„�� � j 'r /\J � ,`:•. '�-� � -� OCT-20-99 09:06 AM PURVIS LAND & TIMBER 910 464 2940 P - `s 4 OPERATION AND MAINTENANCE AGREEMENT FOR THE; DIVISION OF WATER QUALITY F, 22--B37-:1 _ Sinvle l�tuttily Rc -,idt4occ Wastew<<ter Treatment System - Final Disposal by OIL. 11- bl,,� .c �?�]' ?- r.Permit No.: L't .i,�> r -___— -- County. I agree to operatc and maintain the was(uwator treatment systc:rn as, follo%vs: The PCTT[littCC is responsible for the Operation and mainti:nartGC of the entire. treatment and dispo,sat system, including, but not limilted to, the following ilcLn . a. The septic lank shall be. checked annually and pumped out as necded. The effluent filter shall he checked and cluuned at the same f-CgUency as the septic tank. b. The tablet chlorinator shall be checked every week. Tablets shall be added so as to provicic proper chlorination, C. The storage, bump, and alarm s.ystcros shall bc inspected monthly, The scum Dryer shall be removed at thc: sumo time interval as the. septic tauk is cleancd out. d. The spray system shall be inspCCtCd InOrtthly to make certain of the sprayers` proper ()pc.ration, that the vegetative growth allows proper spray patterns, that the soil is assimilating the disposed treated Wastewater with no surface runoff, and that nc, objectionable. odors are hs1119 generated. 2. Failure of (he: Pc:rinittec to properly opc:rtrW this system is subject to a penalty up to S10,000 I)er- day. 3. Failure to meet perniit conditions or violation of the States surface: or-roundwater rt.gcel;iti .>ns will require cessation of occnpancy ofthe builclinc, I understand that f4duri. to comply with these conditions alone with the permit conditions may result in voiding the pe.nttit. Notary Seel I'+ecrttrry Signature: At, r Date.; , � _ My Commission Expires 08-17-kuuj 4L