HomeMy WebLinkAboutWQ0015489_Final Permit_19980714State of North Carolina
Department of Environment
and Natural Resources
Division of Water Quality
James B. Hunt, Jr., Governor
Wayne McDevitt, Secretary
A. Preston Howard, Jr., P.E., Director
July 14, 1998
Mr. Timothy Tippett
3239 Walters Road
Creedmoor, North Carolina 27522
Dear Mr. Tippett:
NCDENR
NORTH CAROLINA DEPARTMENT OF
ENVIRONMENT AND NATURAL RESOURCES
Subject: Permit No. WQ0015489
SFR/Tippett
Spray Irrigation System
Wake County
In accordance with your application received June 16, 1998, we are forwarding herewith Permit No.
WQ0015489, dated July 14, 1998, to Mr. Timothy Tippett for the construction and operation of the subject single
family wastewater treatment and spray irrigation system.
This permit shall be effective from the date of issuance until June 30, 2003, and shall be subject to the
conditions and limitations as specified therein. Please pay particular attention to Condition I1.13. and the
monitoring requirements in this permit. Failure to establish an adequate system for collecting and maintaining the
required operational information will result in future compliance problems.
If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to
request an adjudicatory hearing upon written request within thirty (30) days following receipt of this permit. This
request must be in the form of a written petition, conforming to Chapter 150B of the North Carolina General
Statutes, and fled with the Office of Administrative Hearings, P.O. Drawer 27447, Raleigh, NC 27611-7447.
Unless such demands are made this permit shall be final and binding.
One set of approved plans and specifications is being forwarded to you. If you need additional information
concerning this matter, please contact Ms. Joni Cardin at (919) 733-5083 extenpion 509.
icerel ,
Preston Howard, Jr., P.E.
cc: Wake County Health Department
Duane K. Stewart & Associates, Inc.
Raleigh Regional Office, Water Quality Section
Technical Assistance and Certification Unit
Non -Discharge Compliance/Enforcement Unit
PO Box 29535, Raleigh, North Carolina 27626-0535 Telephone (919) 733-5483 Fax (919) 733-0719
An Equal Opportunity Affirmative Action Employer 50% recycled/10% post -consumer paper
NORTH CAROLINA
ENVIRONMENTAL MANAGEMENT COMMISSION
DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES
RALEIGH
SINGLE FAMILY SPRAY IRRIGATION PERMIT
In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and
other applicable Laws, Rules, and Regulations
PERMISSION IS HEREBY GRANTED TO
Timothy Tippett
Wake County
construction and operation of a 600 -GPD spray irrigation wastewater treatment and disposal system consisting of a
1000 -gallon baffled septic tank to serve the two-bedroom mobile home and a 1000 -gallon baffled septic tank to
serve the three-bedroom house, a distribution box, dual 264 -square -foot, subsurface sand filters, a tablet chlorinator,
two 1500 -gallon storage/pump tanks with minimum 12.6 -GPM pumps with high water alarms, and a 13,609 -
square -foot spray irrigation area which consists of three non -overlapping, full -circle 76 -foot diameter 4.2 -GPM
nozzles to serve the Tippett Residences, with no discharge of wastes to the surface waters, pursuant to the
application received June 16, 1998, and in conformity with the project plan, specifications, and other supporting
data subsequently filed and approved by the Department of Environment and Natural Resources and considered a
part of this permit.
This permit shall be effective from the date of issuance until June 30, 2003, and shall be subject to the
following specified conditions and limitations:
I. PERFORMANCE STANDARDS
Upon completion of construction and prior to operation of this permitted facility, a certification must be
received from a professional engineer certifying that the permitted facility has been installed in
accordance with this permit, the approved plans and specifications, and other supporting materials. If
this project is to be completed in phases and partially certified, you shaIl retain the responsibility to
track further construction approved under the same permit, and shall provide a final certificate of
completion once the entire pr2ject has been completed. Mail the Certification to the Non -Discharge
Permitting Unit, P.O. Box 29535, Raleigh, NC 27626-0535.
2. The Raleigh Regional Office, telephone number (919) 571-4700, shall be notified at least forty-eight
(48) hours in advance of operation of the installed facilities so that an in-place inspection can be made.
Such notification to the regional supervisor shall be made during the normal office hours from 8:00
a.m. until 5:00 p.m. on Monday through Friday, excluding State Holidays.
3. The spray irrigation facilities shall be effectively maintained and operated at all times so that there is no
discharge to the surface waters, nor any contamination of ground waters which will render them
unsatisfactory for normal use_ In the event that the facilities fail to perform satisfactorily, including the
creation of nuisance conditions or failure of the irrigation area to adequately assimilate the wastewater,
the Permittee shall take immediate corrective actions including those actions that may be required by
the Division of Water Quality (Division), such as the construction of additional or replacement
wastewater treatment and disposal facilities.
4. The issuance of this permit shall not relieve the Permittee of the responsibility for damages to surface
or groundwaters resulting from the operation of this facility.
5. The sand media of the subsurface sand filters must comply with the Division's sand specifications. The
engineer's certification will serve as evidence that these specifications have been met.
6. A leakage test shall be performed on the septic tank and dosing tank to insure that any exfiltration
occurs at a rate which does not exceed twenty (20) gallons per twenty-four (24) hours per 1,000 gallons
of tank capacity. The engineer's certification will serve as proof of compliance with this condition.
7. If excavation into bedrock is required for the installation of the septic tank or sand filter, the pit shall be
lined with a 10 mil synthetic liner.
A sanitary tee shall be installed on the effluent pipe of the septic tank. The engineer's certification will
serve as evidence that these specifications have been met.
9. The residuals generated from these treatment facilities must be disposed in accordance with General
Statute 143-215.1 and in a manner approved by the Division.
10. Diversion or bypassing of the untreated wastewater from the treatment facilities is prohibited.
11. The following buffers shall be maintained:
a) 400 feet between wetted area and any residence or places of public assembly under separate
ownership,
b) 150 feet between wetted area and property lines,
c) 100 feet between wetted area and wells,
d) 100 feet between wetted area and drainageways or surface water bodies,
e) 50 feet between wetted area and public right of ways,
f) 100 feet between treatment/storage units and any wells, and
g) 50 feet between treatment units and property lines.
H. OPERATION AND MAINTENANCE REQUIREMENTS
The facilities shall be properly maintained and operated at all times.
Upon classification of the facility by the Water Pollution Control System Operators Certification
Commission (WPCSOCC), the Permittee shall employ a certified wastewater treatment plant operator
to be in responsible charge (ORC) of the wastewater treatment facilities. The operator must hold a
certificate of the type and grade at least equivalent to or greater than the classification assigned to the
wastewater treatment facilities by the WPCSOCC. The Permittee must also employ a certified back-up
operator of the appropriate type and grade to comply with the conditions of 15A NCAC SA .0202. The
ORC of the facility must visit each CIass I facility at least weekly and each Class II, III, and IV facility
at least daily, excluding weekends and holidays, and must properly manage and document daily
operation and maintenance of the facility and must comply with all other conditions of 15A NCAC 8A
.0202. Once the facility is classified, the Permittee must submit a letter to the WPCSOCC which
designates the operator in responsible charge within thirty days after the wastewater treatment facilities
are 50% complete.
A suitable vegetative cover shall be maintained.
4. Irrigation shall not be performed during inclement weather or when the ground is in a condition that
will cause runoff.
5. Adequate measures shall be taken to prevent wastewater runoff from the spray field.
2
6. The application rate shall not exceed a cumulative loading of 2598 inches over any twelve (12) month
period at an instantaneous application rate not to exceed 0.20 inches per hour.
7. The facilities shall be effectively maintained and operated as a non -discharge system to prevent the
discharge of any wastewater resulting from the operation of this facility.
8. No type of wastewater other than that from the Tippett Residences shall be sprayed onto the irrigation
area.
9. In the event that the sprinkler heads fail to achieve the design diameter of 76 feet due to obstructions,
the obstructions shall be removed or the sprinkler heads shall be raised and supported to such height
that the design diameter is achieved.
10. No traffic or equipment shall be allowed on the disposal area except while installation occurs or while
normal maintenance is being performed.
11. The spray irrigation field shall be fenced with at least a two strand wire fence.
12. The Permittee is responsible for the operation and maintenance of the entire treatment and disposal
system including, but not limited to, the following items:
a. The septic tank shall be checked annually and pumped out as needed.
b. The tablet chlorinator shall be checked every week. Tablets shall be added so as to provide proper
chlorination.
c. The storage, pump, and alarm systems shall be inspected weekly. The scum layer shall be removed
at the same interval as the septic tank is cleaned out.
d. The spray system shall be inspected weekly to make certain of the sprayers proper operation, that
the vegetative growth allows a proper spray pattern, that the soil is assimilating the disposed treated
wastewater with no surface runoff, and that no objectionable odors are being generated.
13. The property on which the spray irrigation system is to be/is located cannot be subdivided until each
residence has its own independent wastewater treatment and disposal system.
III. MONITORING AND REPORTING REQUIREMENTS
Any monitoring deemed necessary by the Division to insure surface and ground water protection will
be established and an acceptable sampling reporting schedule shall be followed.
2. The Permittee shall maintain records of all maintenance performed on the system and irrigation area, as
required in Condition 11 12 for a minimum of five years. This information shall be provided to the
Division upon request.
3. Noncompliance Notification:
The Permittee shall report by telephone to the Raleigh Regional Office, telephone number (919) 571-
4700, as soon as possible, but in no case more than 24 hours or on the next working day following the
occurrence or first knowledge of the occurrence of any of the following:
a. Any process unit failure, due to known or unknown reasons, that renders the facility incapable of
adequate wastewater treatment, such as mechanical or electrical failures of pumps, spray heads,
etc.; or
b. Any failure of a pumping station or treatment facility resulting in a by-pass directly to receiving
waters without treatment of all or any portion of the influent to such station or facility.
3
Persons reporting such occurrences by telephone shall also file a written report in letter form within
five (5) days following first knowledge of the occurrence. This report must outline the actions taken or
proposed to be taken to ensure that the problem does not recur.
N. INSPECTIONS
Adequate inspection, maintenance, and cleaning shall be provided by the Permittee to insure proper
operation of the subject facilities.
2. Any duly authorized officer, employee, or representative of the Division may, upon presentation of
credentials, enter and inspect any property, premises or place on or related to the disposal site or
facility at any reasonable time for the purpose of determining compliance with this permit, may inspect
or copy any records that must be maintained under the terms and conditions of this permit, and may
obtain samples of groundwater, surface water, or leachate.
V. GENERAL CONDITIONS
This permit shall become voidable unless the facilities are constructed in accordance with the
conditions of this permit, the approved plans and specifications, and other supporting data.
This permit is effective only with respect to the nature and volume of wastes described in the
application and other supporting data.
This permit is not transferable. In the event there is a desire for the facilities to change ownership, or
there is a name change of the Permittee, a formal permit request must be submitted to the Division
accompanied by an application fee, documentation from the parties involved, and other supporting
materials as may be appropriate. The approval of this request will be considered on its merits and may
or may not be approved.
4. Upon the availability of a municipal or regional sewerage collection system, the subject wastewater
treatment facilities shall be abandoned and all wastewater discharged into the municipal or regional
sewerage system.
Failure to abide by the conditions and limitations contained in this permit may subject the Permittee to
an enforcement action by the Division in accordance with North Carolina General Statute 143-215.6A
to 143-215.6C.
The issuance of this permit does not preclude the Permittee from complying with any and all statutes,
rules, regulations, or ordinances which may be imposed by other government agencies (local, state, and
federal) which have jurisdiction.
7. This permit may be revoked if the Permittee fails to abide by the conditions of the "Operation and
Maintenance Agreement" previously signed by the Permittee.
8. A set of approved plans and specifications for the subject project must be retained by the Permittee for
the life of the project.
9. The Permittee, at least six (6) months prior to the expiration of this permit, shall request its extension.
Upon receipt of the request, the Commission will review the adequacy of the facilities described
therein, and if warranted, will extend the Permit for such period of time and under such conditions and
limitations as it may deem appropriate.
4
Permit issued this the urteenth day of July, 1998
NORTH C OLINA NV O TAL MANAGEMENT COMMISSION
0
/,--A. Preston Howard, Jr., P.E., Director
Division of Water Quality
By Authority of the Environmental Management Commission
Permit Number WQ0015489
Permit No. WQ0015489
July 14, 1998
ENGINEER'S CERTIFICATION
Partial Final
I, , as a duly registered Professional Engineer in the State of North
Carolina, having been authorized to observe (periodically, weekly, full time) the construction of the project,
Project Name
Location and County
for the Permittee hereby state that, to the best of my abilities, due care and diligence was used in the observation of
the construction such that the construction was observed to be built within substantial compliance and intent of this
permit, the approved plans and specifications, and other supporting materials.
Signature
Date
Registration No.
CREEDMOOR QUADRANGLE
' - •�, 4 �..9 \'� .� . , �: i%,��. NORTH CAROLINA
.7 7.5 MINUTE SERIES (TOPOGRAPHIC
SW/4 GRBEDM04R IS' QUADRANGLE '—
I [ � %% �� ` ii � i.gA'4�LL�.. a a. • I f,+ � `1�-f y_ •,:• "tel
e ' : o _�Z 4\1• � �' 'r..:. � ASE - - r ' ' .
•s°' - r �,,� ��s Union
tl'em -o l ' 0•, i'� :- —.` �. � -,i `/lll..
b t ikl-cp
� v of ` ��\�,i �� !•- .\r-.��`i 11 _� ^�,r �.
IV
vii Q �� \\ , q ( ;/.' ✓� { •—. �': )� _ _
em4r f1�
u �–
�� rte x.36
Cem�
Cir h � ' r .l_� � \ �`• ����% �-.^. ���'.~- � ...�-� � r�5.s (- ��-C
i J
X92 \ '�' ✓,I ^>s�� ,v– _- �. �-4�–��-'���
1
to `_ em° �✓ : J f I — — — p_� �a� \�
�'� I ' H.; `(` i � s -- _ __ �]vS � 4lLjli+lti�l :t •
3997
- �/� ✓� �' c� ���ill\��,_ / � ✓��� � �� ~— - _ -- � mit ,.
2'30 '
_ o
(}
J 1900 I , r _� •._, �t
6L
��.
- , SCALE 1:24 000
i 7 0 i MILE
,\
1000 p 1000 2!100 3000 4000 6000 6000 7000 FEET. `
1 KILOMETER
CONTOUR INTERVAL 10 FEET
NATIONAL GEODETIC VERTICAL DATUM OF 1929--