Mr. George R. Farrell, Jr.
354 McGhee Road
Chapel Hill, North Carolina 27514
Dear Mr, Farrell:
January 7, 1998
Subject: Permit No. WQ0014598
George R. Farrell, Jr.
Single Family Wastewater
Spray Irrigation Facility
Chatham County
In accordance with your application received October 27, 1997, we are forwarding herewith Permit
No. WQ0014598, dated January 7, 1998, to George R. Farrell, Jr. for the construction and operation of
the'subject single family wastewater treatment and spray irrigation facilities.
This permit shall be effective from the date of issuance until December 31, 2002, and shall be
subject to the conditions and limitations as specified therein. Please pay particular attention to the
monitoring requirements in this permit. Failure to establish an adequate system for collecting and
maintaining the required operational information will result in future compliance problems. Please note
section number 5, condition number 10 which states that, if the George R. Farrell, Jr. Residence is to be
rented, the rental lease should notify the lessee of the distance between the wetted area and the rental
Property.
If any parts, requirements, or limitations contained in this permit are unacceptable, you have the
right to request an adjudicatory hearing upon written request within thirty (30) days following receipt of
this permit. This request must be in the form of a written petition, conforming to Chapter 150B of the
North Carolina General Statutes, and filed with the Office of Administrative Hearings, P.O. Drawer
27447, Raleigh, NC 27611-7447. Unless such demands are made this permit shall be final and binding.
One set of approved plans and specifications is being forwarded to you. If you need additional
information concerning this matter, please contact Matt Williams at (919) 33-5083 extension 509.
Sincere ,
_KA. Preston Howard, Jr., P.E.
cc: Chatham County Health Department
Dalton Engineering & Associates, P.A.
Raleigh Regional Office, Water Quality Section
Technical Assistance and Certification Unit
Non -Discharge Compliance/Enforcement Unit
P.O. Box 29535, Raleigh, North Carolina 27626-0535 Telephone (919) 733-5083 FAX (919) 733-0719
An Equal Opportunity Affirmative Action Employer 50% recycled/ 10% post -consumer paper
NORTH CAROLINA
ENVIRONMENTAL MANAGEMENT COMMISSION
DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES
RALEIGH
SINGLE FAMILY SPRAY IRRIGATION PERMIT
In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as
amended, and other applicable Laws, Rules, and Regulations
PERMISSION IS HEREBY GRANTED TO
George R. Farrell, Jr.
Chatham County
FOR THE
construction and operation of a 360 GPD spray irrigation wastewater treatment and disposal system
consisting of a 1,000 gallon baffled septic tank, a 1,200 gallon sand filter pump tank, a 12 GPM pump
with high water audible and visual alarms, a covered 144 ft2 pressure dosed sand filter, a tablet
chlorinator, a 3,000 gallon storage/pump tank, 15.2 GPM pump with high water audible and visual
alarms, eight irrigation nozzles, and a 10,800 ft2 spray irrigation area to serve the George R. Farrell, Jr.
Residence, with no discharge of wastes to the surface waters, pursuant to the application received
October 27, 1997, and in conformity with the project plan, specifications, and other supporting data
subsequently filed and approved by the Department of Environment and Natural Resources and considered
a part of this permit.
This permit shall be effective from the date of issuance until December 31, 2002, and shall be
subject to the following specified conditions and limitations:
I. PERFORMANCE STANDARD
1, Upon completion of construction and prior to operation of this permitted facility, a
certification must be received from a professional engineer certifying that the permitted
facility has been installed in accordance with this permit, the approved plans and
specifications, and other supporting materials. If this project is to be completed in phases
entire project has been completed. Mail the Certification to the Non -Discharge Permitting
Unit, P.O. Box 29535, Raleigh, NC 27626-0535.
2_ The Raleigh Regional Office, telephone number (919) 571-4700, shall be notified at least
forty-eight (48) hours in advance of operation of the installed facilities so that an in-place
inspection can be made. Such notification to the regional supervisor shall be made during
the normal office hours from 8:00 a.m. until 5:00 p.m. on Monday through Friday,
excluding State Holidays.
3 . The spray irrigation facilities shall be effectively maintained and operated at all times so that
there is no discharge to the surface waters, nor any contamination of ground waters which
will render them unsatisfactory for normal use. In the event that the facilities fail to
perform satisfactorily, including the creation of nuisance conditions or failure of the
irrigation area to adequately assimilate the wastewater, the Permittee shall take immediate
corrective actions including those actions that may be required by the Division of Water
Quality (Division), such as the construction of additional or replacement wastewater
treatment and disposal facilities.
4. The issuance of this permit shall not relieve the Permittee of the responsibility for damages
to surface or groundwaters resulting from the operation of this facility.
5. The sand media of the pressure dosed sand filer must comply with the Division's sand
specifications. The engineer's certification will serve as evidence that these specifications
have been met.
6. A leakage test shall be performed on the septic tank and dosing tank to insure that any
exfiltration occurs at a rate which does not exceed twenty (20) gallons per twenty-four (24)
hours per 1,000 gallons of tank capacity. The engineer's certification will serve as proof of
compliance with this condition.
7. If excavation into bedrock is required for the installation of the septic tank or sand filter, the
pit shall be lined with a 10 mil synthetic liner.
8. A sanitary tee shall be installed on the effluent pipe of the septic tank. The engineer's
certification will serve as evidence that these specifications have been met.
9. The residuals generated from these treatment facilities must be disposed in accordance with
General Statute 143-215.1 and in a manner approved by the Division.
10. Diversion or bypassing of the untreated wastewater from the treatment facilities is
prohibited.
11. The following buffers shall be maintained:
a) 400 feet between wetted area and any residence or places of public assembly under
separate ownership,
b) 150 feet between wetted area and property lines,
c) 100 feet between wetted area and wells,
d) 100 feet between wetted area and drainageways or surface water bodies,
e) 50 feet between wetted area and public right of ways,
f) 100 feet between treatment/storage units and any wells, and
g) 50 feet between treatment units and property lines.
Some of the buffers specified above may not have been included in previous permits for
this waste treatment and disposal system. These buffers are not intended to prohibit or
prevent modifications, which are required by the Division, to improve performance of the
existing treatment facility. These buffers do, however, apply to modifications of the
treatment and disposal facilities which are for the purpose of increasing the flow that is
tributary to the facility. These buffers do apply to any expansion or modification of the
spray irrigation areas and apply in instances in which the sale of property would cause any
of the buffers now complied with, for the treatment and disposal facilities, to be violated.
The applicant is advised that any modifications to the existing facilities will require a permit
modification.
H. OPERATION. AND MAINTENANCE REQUIREMENTS
The facilities shall be properly maintained and operated at all times.
2. Upon classification of the facility by the Water Pollution Control System Operators
Certification Commission (WPCSOCC), the Permittee shall employ a certified wastewater
treatment plant operator to be in responsible charge (ORC) of the wastewater treatment
facilities. The operator must hold a certificate of the type and grade at least equivalent to or
greater than the classification assigned to the wastewater treatment facilities by the
WPCSOCC. The Permittee must also employ a certified back-up operator of the
appropriate type and grade to comply with the conditions of 15A NCAC 8A .0202. The
ORC of the facility must visit each Class I facility at least weekly and each Class II, III, and
IV facility at least daily, excluding weekends and holidays, and must properly manage and
document daily operation and maintenance of the facility and must. comply with all other
conditions of 15A NCAC 8A .0202. Once the facility is classified, the Permittee must
submit a letter to the WPCSOCC which designates the operator in responsible charge
within thirty days after the wastewater treatment facilities are 50% complete.
3. A suitable vegetative cover of Fescue shall be maintained.
4. Irrigation shall not be performed during inclement weather or when the ground is in a
condition that will cause runoff.
5. Adequate measures shall be taken to prevent wastewater runoff from the spray field.
6. The application rate shall not exceed a cumulative loading of 21.4 inches over any twelve
(12) month period at an instantaneous application rate not to exceed 0.33 inches per hour.
7. The facilities shall be effectively maintained and operated as a non -discharge system to
prevent the discharge of any wastewater resulting from the operation of this facility.
8. No type of wastewater other than that from the George R. Farrell, Jr. Residence shall be
sprayed onto the irrigation area.
9. In the event that the sprinkler heads fail to achieve the design diameter of 30 feet due to
obstructions, the obstructions shall be removed or the sprinkler heads shall be raised and
supported to such height that the design diameter is achieved.
10. No traffic or equipment shall be allowed on the disposal area except while installation
occurs or while normal maintenance is being performed.
11. The spray irrigation field shall be fenced with at least a two strand wire fence.
12. The Permittee is responsible for the operation and maintenance of the entire treatment and
disposal system including, but not limited to, the following items:
a. The septic tank shall be checked annually and pumped out as needed.
b. The tablet chlorinator shall be checked every week. Tablets shall be added so as to
provide proper chlorination.
c. The storage, pump, and alarm systems shall be inspected weekly. The scum layer shall
be removed at the same interval as the septic tank is cleaned out.
d. The spray system shall be inspected weekly to make certain of the sprayers proper
operation, that the vegetative growth allows a proper spray pattern, that the soil is
assimilating the disposed treated wastewater with no surface runoff, and that no
objectionable odors are being generated.
III. MONITORING AND REPORTING REQUIREMENTS
1. Any monitoring deemed necessary by the Division to insure surface and ground water
protection will be established and an acceptable sampling reporting schedule shall be
followed.
2. The Permittee shall maintain records of all maintenance performed on the system and
irrigation area, as required in Condition II 12 for a minimum of five years. This
information shall be provided to the Division upon request.
3. Noncompliance Notification:
The Permittee shall report by telephone to the Raleigh Regional Office, telephone number
(919) 571-4700, as soon as possible, but in no case more than 24 hours or on the next
working day following the occurrence or first knowledge of the occurrence of any of the
following:
a. Any process unit failure, due to known or unknown reasons, that renders the facility
incapable of adequate wastewater treatment, such as mechanical or electrical failures of
pumps, spray heads, etc.; or
b. Any failure of a pumping station or treatment facility resulting in a by-pass directly to
receiving waters without treatment of all or any portion of the influent to such station or
facility.
Persons reporting such occurrences by telephone shall also file a written report in letter
form within five (5) days following first knowledge of the occurrence. This report must
outline the actions taken or proposed to be taken to ensure that the problem does not recur.
I V . INSPECTIONS
1. Adequate inspection, maintenance, and cleaning shall be provided by the Permittee to
insure proper operation of the subject facilities.
2. Any duly authorized officer, employee, or representative of the Division may, upon
presentation of credentials, enter and inspect any property, premises or place on or related
to the disposal site or facility at any reasonable time for the purpose of determining
compliance with this permit, may inspect or copy any records that must be maintained
under the terms and conditions of this permit, and may obtain samples of groundwater,
surface water, or leachate.
V. GENERAL CONDITIONS
This permit shall become voidable unless the facilities are constructed in accordance with
the conditions of this permit, the approved plans and specifications, and other supporting
data.
2. This permit is effective only with respect to the nature and volume of wastes described in
the application and other supporting data.
This permit is not transferable. In the event there is a desire for the facilities to change
ownership, or there is a name change of the Permittee, a formal permit request must be
submitted to the Division accompanied by an application fee, documentation from the
parties involved, and other supporting materials as may be appropriate. The approval of
this request will be considered on its merits and may or may not be approved.
4
4. Upon the availability of a municipal or regional sewerage collection system, the subject
wastewater treatment facilities shall be abandoned and all wastewater discharged into the
municipal or regional sewerage system.
5. Failure to abide by the conditions and limitations contained in this permit may subject the
Permittee to an enforcement action by the Division in accordance with North Carolina
General Statute 143-215.6A to 143-215.6C.
6. The issuance of this permit does not preclude the Permittee from complying with any and
all statutes, rules, regulations, or ordinances which may be imposed by other government
agencies (local, state, and federal) which have jurisdiction.
7. This permit may be revolted if the Permittee fails to abide by the conditions of the
"Operation and Maintenance Agreement" previously signed by the Permittee.
8. A set of approved plans and specifications for the subject project must be retained by the
Permittee for the life of the project.
9. The Permittee, at least six (6) months prior to the expiration of this permit, shall request its
extension. Upon receipt of the request, the Commission will review the adequacy of the
facilities described therein, and if warranted, will extend the Permit for such period of time
and under such conditions and limitations as it may deem appropriate.
10. If the George R. Farrell, Jr. Residence is to be rented, the rental lease should notify the
lessee of the distance between the wetted area and the rental property.
Permit issued this the 7th day of January, 1998
NORT/COLINA E V O NTAL MANAGEMENT COMMISSION
A. Preston Howard, Jr., RE., Director
Division of Water Quality
By Authority of the Environmental Management Commission
Permit Number WQ0014598
Permit No, WQ0014598
January 7, 1998
ENGINEER'S CERTIFICATION
Partial Final
L I, as a duly registered Professional Engineer in the State of North Carolina,
having been authorized to observe (periodically, weekly, full time) the construction of the
prod ect,
Project Name Location and County
for the
Permittee hereby state that, to the best of my abilities, due care and diligence was used in the observation
of the construction such that the construction was observed to be built within substantial compliance and
intent of this permit, the approved plans and specifications, and other supporting materials.
Signature
Date
0
Registration No.
Kip OPERATION AND MAINTENANCE AGREE.NIENT FOR THE
DIVISION OF ENVIRONMENTAL MANAGEMENT
\�nLN' am c e.d
c
Address.
cY ckc�d ttt Statc: Iy �' ZIP:
City:
Single Family Residence Wastewater Treatment System
Final Disposal by Spray irrigation
Permit No. iySS`�
�CA cv ✓ I _ County
I agree w operate and ma=un the wastewater treatment system as follows:
I . The Permittee is responsible for the operation and maintenance cf the enure treatment and
disposal cyst_—n including, but not limited to, the following items:
a. The septic tank shall be checked every six (6) months and pumped out as required.
b, The tablet chlorinator shall be checked every week until the actual usage rate is established
and thence or, a monthly basis. Tablets shall be added so as to provide proper chlorination.
c. The storage system, pump system, and alarm system shall be inspected monthly. The
scum layer shall be removed at the same interval as the septic sank is cleaned out.
The spray system shall be inspected monthly to make certain of the sprayers proper
operation, that the vegetative growth allows proper spray pattcrrts, that the soil i.s absorbing
the disposed treated wastewater with no surface runoff, and that no objectionable odors are
being generated.
2. Failure of the Permittee to properly operate this system is subject to a penalty up to -S10,000 per
day.
3 . Failure to meet permit conditions or violation of the State's surface or groundwater regulations
will require cessation of occupancy of the residence.
I understand that failure to comply with these conditions along with the permit conditions may result in
voiding the permit.
/ r
Slgnaturc: a L�
Notary Seal
DatC Jobzjq
Notary 5ignarurc: Date -00 '3q
My (aOMR i W Expires Jar 6,
f .,
Fa.rrc,H rw�r> j
3966
":^ �'� -E FOR CLASSIFICATICN'OF WATER POLLUTION CONTROL SYSTEFJ!5
Name of Facility: 6eage
R Farrej��7�
{chec , al, t;^its I.1,at appty)
Owner or Contact Person:
units That apply)
1. sep'�c finks
Nafilno Address: �s
�r
kA / 1 �f ,V "11
75-/91
C n'.1nl�r 64dr
]a^ Telephone:
3 � -(OE
Present Classification:
New Facility i/ Existing Facility
NPDES Per, No. NCOO
Nondisc. Per. No. Health Dept. Per. No _
Rated by:
Telephone:
Date:
Reviewed by:
Health Dept.
Telephone:
sand fillers
Regional Office
Telephone:
#14tf �V lir'
r Central Office
Telephone:
CRC:
Grade:
Telephone'
Check Classifications):
Subsurface _/ Spray Irrigation
LandApplication
Wastewater Classification: (Circle One) 1 11 ill IV
total Points:
I': -P R' ^ Fr1��Gcsc ASD A T D �r iPl,�=hrr V+rrl�-I AR= Aft lh'f +PERT F Ih R' 1 P � T '
r,v b= V, t,S7E ATT {Fn i F{Y: TH= PiJRa SE Or: C,11A5S!F ICt6]C}^ti' 61 SO S -EM -TAW SYME12Z CI ."n SIN
':) �Zg1riTY f 7gl i .4TYJ; L1N=5F.pr EX! r!:?T FRO,' GL4S51FMATIONtt
SJACJRFF,CSC 4—S,&Fr-. TKYN
SPRtYIRRICATIONCLASSIFICATi )N
{chec , al, t;^its I.1,at appty)
(check EP
units That apply)
1. sep'�c finks
1-
Lpreliminary ttealmenl (definition no. 32 }
2 pump, tants
2.
la000ns
sip! n o. pum,}dosine syslerns
3.
septic tanks
sand lifters
d.
pump tanks
a,ease Iraar;ntErcep:cr
$
pumps
E. c,:Vv.alcr separalors
Ei.
sand fillers
i. subs+rfa e frEaIrrienl end disposa:.
7.
grease trapffnterceplor
nravily
8.
oilfwaler separators
Lress'ure
a
disinfection
1D.
chemical addition for
nulfientlaloae control
spray irrigalion of waslewafer
Freuee:cen; of wes;eweter ir, excess of these r:omponents shall be rated using tr,e point rating
sysIErr. enc r, 711 reeuire en operator with an appropriate dual cerlificelion.
,A=P�ICA710 IP.ES1DUAt_S CLASSIFICATION (Applies only to permit holder)
1. Lanc s;plicalion of biosolids, residuals or rontaminefed soils on a designated site.
%.E.A7 LEE FACILITY C!_ASSIFKATION
-r_ s,s!e-ns s ,a' be assiored a Class I class:ficalion, unless the fiow is of a sionlricanl quanlity or the technology is
Cc -,Y er, tc re: ;u�re cens;deration by the Cos•mission on ". a ca -by -case basis: (Check it Appropriale)
r.e er SEPc,2tor Sys:erns tonsislinc only of physica� separation, pumps and disposal,
2 Se '.,c Tan 'Sand Filler Systems consisl,ne only of septic lanky, eosino apparatus, pumps,sand lillers,.lsiniection
a',c d!E-V 6i5Gh2r9e;
Left, Systems censislinc only o' p•el,mhary IreatmeW, ieaoon;, pumps, disinfection, necessary chemical
1reaa'mcn; for arae or nuliienl consrol, and direct disc!-.eroe;
ciC*EIODp FieCy'CIE Systems:
5 Grc_-;dy.e:er Re-ediahon Syslems consistino only o! pumps, air stripping, carbor adsorption, disinsection and
dts Cscl;
E Fish la-rns with discharoe to surface waters:
t','a:e• F,an; sludge hand ,nc and bari -vrash water lrealmen';
processing cons:ving o1 screeninc and dispose!.
S_ _S .. a ia.-ily d.scharc:ac systems wish the exception c! Aerobic Treatment Unils w10 be classified if permilled alter
" 1cc3 o- i' upar b'•' the Division i�_ is four.: that she systerr. is no! be;rc adequa ely eaeraled or
u' c',C:' sjt— Sj5�e-s wit! be nn:ll,ec C' IriE C a55''iC2:,C'. or reLi4551'eCa;,C' by the C.GS,miss, bn, in wnimc