HomeMy WebLinkAboutWQ0013769_Final Permit_20041130O�O� W A T�QG
Q �
November 30, 2004
GARY AND KRISTIN SYDNOR
320 HENDERSON TANYARD ROAD
PITTSSORO, NORTH CAROLINA 27312
Dear Mr. and Ms. Sydnor:
Michael F. Easley, Governor
William G. Ross Jr., Secretary
North Carolina Department of Environment and Natural Resources
Alan W. Klimek, P.E. Director
Division of Water Quality
Subject: Permit No. WQ0013769
Sydnor SFR
Single Family Residence
Surface Irrigation Facility
Chatham County
In accordance with your renewal request received December 29, 2003, we are forwarding
herewith Permit No. WQ0013769, dated November 30, 2004, to Gary and Kristin Sydnor for the
continued operation of the subject single family wastewater treatment and surface irrigation facilities.
This permit shall be effective from the date of issuance until October 31, 2009, shall void Permit
No. WQ0013769 issued June 20, 1997, and shall be subject to the conditions and limitations as specified
therein. Please pay particular attention to the monitoring requirements in this permit. Failure to establish
an adequate system for collecting and maintaining the required operational information will result in
future compliance problems.
During the site visit, the reviewer determined that several items need attention. The septic tank
has a Iarge amount of solids and should be pumped and the septic tank should be checked at least
annually. The caps on the two chlorine table tubes are cracked and should be replaced. The fence around
the spray field shall be reinstalled. Even though the sprinklers have recently been replaced, two are
plastic, one is a pot metal material and only the metal one is attaining a 38 -foot radius, which is required
to have adequate application area according to the permit.
At least six (6) months prior to the expiration of this permit, an extension shall be requested.
Upon receipt of the request, the Commission will review the adequacy of the facility described therein,
and if warranted, will extend the permit for such period of time and under such conditions and limitations,
as it may deem appropriate.
If any parts, requirements, or limitations contained in this permit are unacceptable, you have the
right to request an adjudicatory hearing upon written request within thirty (30) days following receipt of
this permit. This request must be in the form of a written petition, conforming to Chapter 150B of the
North Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service
Center, Raleigh, NC 27699-6714. Unless such demands are made this permit shall be final and binding.
NorthCarolina
Naturally
Aquifer Protection Section 1636 Mail Service Center Raleigh, NC 27699-1636 Phone (919) 733-3221 Customer Service
Internet: http://h2o.e.nr.slate.nc,us 2728 Capital Boulevard Raleigh, NC 27604 Fax (919) 715-0588 1-877-623.6748
Fax (919)715-6049
An Equal Opportunity/Affirmative Action Employer— 50% Recycledf10% Post Consumer Paper
If you need additional information concerning this matter, please contact Nathaniel Thornburg at
(919) 715-6160.
Sincerely,
*-Alan W. Klimek, P. E.
cc: Chatham County Health Department
Raleigh Regional Office - Aquifer Protection Section
Technical Assistance and Certification Unit
APS Central Files (WQ0013769)
LAU Files
0
NORTH CAROLINA
ENVIRONMENTAL MANAGEMENT COMMISSION
DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES
RALEIGH
SINGLE FAMILY RESIDENCE SURFACE IRRIGATION PERMIT
In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as
amended, and other applicable Laws, Rules, and Regulations
PERMISSION IS HEREBY GRANTED TO
Gary and Kristin Sydnor
Chatham County
FOR THE
continued operation of a 360 gallon per day (GPD) spray irrigation wastewater treatment and disposal
system consisting of a 1000 gallon baffled septic tank, a 396 square foot (ft) unvented subsurface sand
filter, a tablet chlorinator, a 2000 gallon storage/pump tank, a submersible pump and motor and a 13,608
ftZ spray irrigation area covered by three (3) full -circle sprinklers to serve the Sydnor residence with no
discharge of wastes to the surface waters, pursuant to the application received December 29, 2003, and in
conformity with the project plan, specifications, and other supporting data subsequently filed and
approved by the Department of Environment and Natural Resources and considered a part of this permit.
This permit shall be effective from the date of issuance until October 31, 2009, shall void Permit
No. WQ0013769 issued June 20, 1997 and shall be subject to the following specified conditions and
limitations:
L PERFORMANCE STANDARDS
The surface irrigation facilities shall be effectively maintained and operated at all times so that
there is no discharge to surface waters, nor any contamination of ground waters, which will
render them unsatisfactory for normal use. In the event that the facilities fail to perform
satisfactorily, including the creation of nuisance conditions or failure of the irrigation area to
adequately assimilate the wastewater, the Permittee shall take immediate corrective actions
including those actions that may be required by the Division of Water Quality, such as the
construction of additional or replacement wastewater treatment and disposal facilities_
2. The issuance of this permit shall not relieve the Permittee of the responsibility for damages to
surface or ground waters resulting from the operation of this facility.
3. The residuals generated from these treatment facilities must be disposed in accordance with
General Statute 143-215.1 and in a manner approved by the Division.
4. Diversion or bypassing of the untreated wastewater from the treatment facilities is prohibited.
5. The following buffers shall be maintained:
a. 400 feet between wetted area and any residence or places of public assembly under separate
ownership,
b. 150 feet between wetted area and property lines,
c. 100 feet between wetted area and wells,
d. 100 feet between wetted area and drainage ways or surface water bodies,
e. 50 feet between wetted area and public right of ways,
f. 100 feet between treatment/storage units and any wells, and
g. 50 feet between treatment units and property lines.
Some of the buffers specified above .may not have been included in previous permits for this
waste treatment and disposal system. These buffers are not intended to prohibit or prevent
modifications, which are required by the Division, to improve performance of the existing
treatment facility. These buffers do, however, apply to modifications of the treatment and
disposal facilities that are for the purpose of increasing the flow that is tributary to the facility.
These buffers do apply to any expansion or modification of the surface irrigation areas and
apply in instances in which the sale of property would cause any of the buffers now complied
with, for the treatment and disposal facilities, to be violated. The applicant is advised that any
modifications to the existing facilities will require a permit modification.
6. The pump tank(s) shall have functional audible and visual high water alarms that are external to
any structure.
II. OPERATION AND MAINTENANCE REQUIREMENTS
1. The facilities shall be properly maintained and operated at all times.
2. Upon classification of the wastewater treatment and surface irrigation facilities by the Water
Pollution Control System Operators Certification Commission (WPCSOCC), the Permittee
shall designate and employ a certified operator to be in responsible charge (ORC) and one or
more certified operator(s) to be back-up ORC(s) of the facilities in accordance with 15A NCAC
SG .0201. The ORC shall visit the facilities in accordance with 15A NCAC SG .0204 or as
specified in this permit and shall comply with all other conditions specified in these rules.
3. A suitable year round vegetative cover shall be maintained
4. Irrigation shall not be performed during inclement weather or when the ground is in a condition
that will cause runoff.
5. Adequate measures shall be taken to prevent wastewater runoff from the irrigation field.
6. The application rate shall not exceed a cumulative loading of 17.16 inches over any twelve (12)
month period at an instantaneous application rate not to exceed 0.20 inches per hour.
7. The facilities shall be effectively maintained and operated as a non -discharge system to prevent
the discharge of any wastewater resulting from the operation of this facility.
S. No type of wastewater other than that from the Sydnor residence shall be sprayed onto the
irrigation area.
9. No traffic or equipment shall be allowed on the disposal area except while installation occurs or
while normal maintenance is being performed.
10. The irrigation field shall be fenced with at least a two -strand wire fence.
2
11. Wastewater treatment units open to the atmosphere shall have restricted access and pump
control panels shall be locked.
12. The Permittee is responsible for the operation and maintenance of the entire treatment and
disposal system including, but not limited to, the following items:
a. The septic tank shall be checked annually and pumped out as needed. The septic tank
effluent filter shall be checked and cleaned at the same frequency of the septic tank.
b. The tablet chlorinator shall be checked every week. Tablets shall be added to provide
proper chlorination.
c. The storage, pump, and alarm systems shall be inspected monthly. The scum layer shall be
removed at the same interval as the septic tank is cleaned out.
d. The system shall be inspected monthly to make certain of the proper operation of the spray
heads, that the vegetative growth allows a proper spray pattern, that the soil is assimilating
the disposed treated wastewater with no surface runoff, and that no objectionable odors are
being generated.
III. MONITORING AND REPORTING REQUIREMENTS
1. Any monitoring deemed necessary by the Division to insure surface and ground water
protection will be established and an acceptable sampling reporting schedule shall be followed.
2. The Permittee shall maintain records of all maintenance performed on the system and irrigation
area, as required in Condition Tl(12) for a minimum of five years. This information shall be
provided to the Division upon request.
3. Noncompliance Notification:
The Permittee shall report by telephone to the Raleigh Regional Office, telephone number (919)
571-4700, as soon as possible, but in no case more than 24 hours or on the next working day
following the occurrence or first knowledge of the occurrence of any of the following:
a. Any process unit failure, due to known or unknown reasons, that renders the facility
incapable of adequate wastewater treatment, such as mechanical or electrical failures of
pumps, spray heads, etc.; or
b. Any failure of a pumping station or treatment facility resulting in a by-pass directly to
receiving waters without treatment of all or any portion of the influent to such station or
facility.
Occurrences outside normal business hours may also be reported to the Division's Emergency
Response personnel at telephone number (800) 858-0368 or (919) 733-3300. Persons reporting
such occurrences by telephone shall also file a written report in letterform within five (5) days
following first knowledge of the occurrence. This report must outline the actions taken or
proposed to be taken to ensure that the problem does not recur.
91
IV.
V
INSPECTIONS
1. Adequate inspection, maintenance, and cleaning shall be provided by the Permittee to insure
proper operation of the subject facilities.
2. Any duly authorized officer, employee, or representative of the Division may, upon
presentation of credentials, enter and inspect any property, premises or place on or related to
the disposal site or facility at any reasonable time for the purpose of determining compliance
with this permit, may inspect or copy any records that must be maintained under the terms and
conditions of this permit, and may obtain samples of groundwater, surface water, or leachate.
GENERAL CONDITIONS
This permit shall become void unless the facilities are constructed in accordance with the
conditions of this permit, the approved plans and specifications, and other supporting data.
2. This permit is effective only with respect to the nature and volume of wastes described in the
application and other supporting data.
This permit is not transferable. In the event there is a desire for the facilities to change
ownership, or there is a name change of the Permittee, a formal permit request must be
submitted to the Division accompanied by documentation from the parties involved, and other
supporting materials as may be appropriate. The approval of this request will be considered on
its merits and may or may not be approved.
4. Upon the availability of a municipal or regional sewerage collection system, the subject
wastewater treatment facilities shall be abandoned and all wastewater discharged into the
municipal or regional sewerage system.
Failure to abide by the conditions and limitations contained in this permit may subject the
Permittee to an enforcement action by the Division in accordance with North Carolina General
Statute 143-215.6A to 143-215.6C.
6. The issuance of this permit does not preclude the Permittee from complying with any and all
statutes, rules, regulations, or ordinances, which may be imposed by other government agencies
(local, state, and federaI), which have jurisdiction.
7. This permit may be revoked if the Permittee fails to abide by the conditions of the "Operation
and Maintenance Agreement" previously signed by the Permittee.
8. The Permittee shall retain a set of approved plans and specifications of the subject facility for
the life of the project.
9. The Permittee shall pay the annual administering and compliance fee within 30 days of being
billed by the Division. Failure to pay the fee accordingly may cause the Division to initiate
action to revoke this permit as specified by ISA NCAC 2H.0205 (c)(4).
10. The Permittee, at least six (6) months prior to the expiration of this permit, shall request its
extension. Upon receipt of the request, the Commission will review the adequacy of the
facilities described therein, and if warranted, will extend the Permit for such period of time and
under such conditions and limitations, as it may deem appropriate.
4
Permit issued this the 30th day of November, 2004
NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION
"Alan W. Klimek, P.E., Director
Division of Water Quality
By Authority of the Environmental Management Commission
Peradt Number WQ001.3769