HomeMy WebLinkAboutWQ0010742_Final Permit_20141212NCDENR
No' h Carolina Department of Enviroilm&-it and Natural Resources
Pat McCrory
Governor
December 12, 2014
Matthew T. and Jana M. Callahan
3 593 Horseshoe Road
Creedmoor, North Carolina 27522
Dear Mr. and Mrs. Callahan:
Joan E. Skvarla, III
Secretary
Subject: Permit No. WQOO10742
3593 Horseshoe Road,
Creedmoor, NC SFR
Single -Family Residence
Wastewater Irrigation System
Wake County
In accordance with your renewal request received October 20, 2014, we are forwarding herewith
Permit No. WQ0010742 dated December 12, 2014, to Matthew T. and Jana M. Callahan for the continued
operation of the subject single-family residence wastewater treatment and irrigation facilities.
This permit shall be effective from April 1, 2015 until March 30, 2020, shall void Permit No.
WQ0010742 issued April 7, 2006 and shall be subject to the conditions and limitations as specified
therein. An extension shall be requested at least six months prior to the expiration of this permit.
Upon receipt of the request, the Commission will review the adequacy of the facility described therein
and, if warranted, will extend the permit for such period of time and under such conditions and limitations
as it may deem appropriate.
Please pay particular attention to the operation and maintenance requirements listed in Section III
for they may differ from the previous permit issuance. Failure to establish an adequate system for
collecting and maintaining the required operational information shall result in future compliance
problems. Also note that Condition VI.6. requires the Permittee to retain a set of Division approved plans
and specifications for the life of the facilities permitted herein.
If any parts, requirements or limitations contained in this permit are unacceptable, the Permittee
has the right to request an adjudicatory hearing upon written request within 30 days following receipt of
this permit. This request shall be in the form of a written petition, conforming to Chapter 150B of the
North Carolina General Statutes, and filed with the Office of Administrative Hearings at 6714 Mail
Service Center, Raleigh, NC 27699-6714. Unless such demands are made, this permit shall be final and
binding.
Non -Discharge Peiniffing Unit
1617 [Jail Sen'ce Center, Raleigh, North Carais 27699-1617
Ph one: 919 807-646411ntemet: htt :Jf otlal.s{cdenr.a 1we�Mr
AIS Eq aI C:porWnity S Affinaiw-Ac;ion Empoyer- Made in W YAf r8rick;7 paper
Mr. and Mrs. Callahan
December 12, 2014
Page 2 of 2
If you need additional information concerning this matter, please contact Alice M. Wessner at
(919) 807-6425 or alice.wessner@ncdenr.gov.
Sincerely,
/homas A. Reeder, Director
Division of Water Resources
cc: Wake County Health Department (EIectronic Copy) Health Director: Sue Lynn Ledford
E -Mail: sue. ledfordreo.wake.nc.us
Raleigh Regional Office, Water Quality Regional Operations Section (Electronic Copy)
Central Files
Digital Permit Archive (Electronic Copy)
NORTH CAROLINA
ENVIRONMENTAL MANAGEMENT COMMISSION
DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES
RALEIGH
SINGLE-FAMILY RESIDENCE WASTEWATER IRRIGATION SYSTEM PERMIT
In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as
amended, and other applicable Laws, Rules and Regulations
PERMISSION IS HEREBY GRANTED TO
Matthew T. and Jana M. Callahan
Granville County
FOR THE
continued operation of a 480 gallon per day (GPD) surface spray irrigation wastewater treatment and
disposal system consisting of:
a 1,000 gallon baffled septic tank, a 1,000 gallon dosing tank, a 144 square foot surface sand filter with a
cover, a tablet chlorinator disinfection unit, a 3,000 gallon storage/pump tank, and a 17,328 square foot
spray irrigation area and all associated piping and appurtenances, to serve the Callahan residence (3761
Mason Road, New Hill, NC) with no discharge of wastes to the surface waters, pursuant to the application
received October 20, 2014, and in conformity with the project plan, specifications, and other supporting
data subsequently filed and approved by the Department of Environment and Natural Resources and
considered a part of this permit.
This permit shall be effective from April 1, 2015 until March 30, 2020, shall void Permit No.
WQ0010742 issued April 7, 2006 and shall be subject to the following specified conditions and
limitations:
L SCHEDULES
No later than six months prior to the expiration of this permit, the Permittee shall request renewal of
this permit on official Division forms. Upon receipt of the request, the Division will review the
adequacy of the facilities described therein, and if warranted, will renew the permit for such period of
time and under such conditions and limitations as it may deem appropriate. Please note Rule 15A
NCAC 02T .0105(d) requires an updated site map to be submitted with the permit renewal
application.
2. In accordance with 15A NCAC 02T .0607, if a public or community sewage system is or becomes
available, the subject single-family residence wastewater treatment and irrigation facilities shall be
closed and all wastewater shall be discharged into the public or community sewage system within 180
days of its availability. Prior to the initiation of these connection activities, appropriate Division
approval shall be received.
WQ0010742 Version 3.0 Shell Version 141027 Page 1 of 6
H. PERFORMANCE STANDARDS
The subject non -discharge facilities shall be effectively maintained and operated at all times so there
is no discharge to surface waters, nor any contravention of groundwater or surface water standards.
In the event the facilities fail to perforin satisfactorily, including the creation of nuisance conditions
due to improper operation and maintenance, or failure of the irrigation areas to adequately assimilate
the effluent, the Permittee shall take immediate corrective actions including Division required actions,
such as the construction of additional or replacement wastewater treatment or disposal facilities.
2. This permit shall not relieve the Permittee of their responsibility for damages to groundwater or
surface water resulting from the operation of this facility.
3. Application rates, whether hydraulic, nutrient or other pollutant, shall not exceed those specified in
the following table:
TABLE 1— APPLICATION LIMITATIONS
Field
Parameter
Hourly Rate
Yearly Max
Units
1
01284 — Non -Discharge application rate
0.2
16.1
inches
4- The subject facility has been approved to land apply wastewater effluent on the following fields:
TABLE 2 — IRRIGATION AREA INFORMATION
Field
Owner
County
Latitude
Longitude
Net Acreage
Dominant
Soil Series
Callahan,
1
Matthew T. and
Wake
35040'39"
78055'25"
0.4
Jana M.
TotalI
1
1 0.4
5. The Operation and Maintenance Agreement (attached) between the Permittee and the Division of
Water Resources is incorporated herein by reference and shall be a condition of this permit.
Noncompliance with the terms of the Operation and Maintenance Agreement shall subject the
Permittee to all sanctions provided by North Carolina General Statutes § 143-215.6A to § 143-215.6C
for violation of or failure to act in accordance with the terms and conditions of this permit.
6. In accordance with 15A NCAC 02L .0107(i), the compliance boundary is established at the property
boundary. Any exceedance of standards at the compliance boundary shall require action in
accordance with 15A NCAC 02L .0106.
7. In accordance with 15A NCAC 02L .0108, the review boundary is established midway between the
compliance boundary and the effluent disposal area. Any exceedance of groundwater standards at the
review boundary shall require action in accordance with 15A NCAC 02L .0106.
8. The Permittee shall apply for a permit modification to establish a new compliance boundary prior to
any sale or transfer of property affecting a compliance boundary.
9. The facilities permitted herein shall be constructed according to the following setbacks:
a. The setbacks for irrigation sites permitted under 15A NCAC 02H .0200 shall be as follows (all
distances in feet):
i. Any habitable residence or place of public assembly under separate ownership
ii. Surface waters:
iii. Any well with exception of monitoring wells:
iv. Any property line:
400
100
100
150
WQ0010742 Version 3.0 Shell Version 141027 Page 2 of 6
v. Public right of way: 50
b. The setbacks for storage and treatment units permitted under 15A NCAC 02H .0200 shall be as
follows (all distances in feet):
i. Any well with exception of monitoring wells: 100
ii. Any property line: 50
III. OPERATION AND MAINTENANCE REQUIREMENTS
I. The facilities shall be properly maintained and operated at all times. The facilities shall be effectively
maintained and operated as a non -discharge system to prevent the discharge of any wastewater
resulting from the operation of this facility. The Permittee shall maintain an Operation and
Maintenance Plan pursuant to 15A NCAC 02T .0604(£).
2. Upon the Water Pollution Control System Operators Certification Commission's (WPCSOCC)
classification of the subject non -discharge facilities, in accordance with 15A NCAC 08G .0200 the
Permittee shall designate and employ a certified operator in responsible charge (ORC) and one or
more certified operator(s) as back-up ORC(s). The ORC or their back-up shall visit the facilities in
accordance with 15A NCAC 08G .0200, and shall comply with all other conditions specified in the
previously cited rules.
3. A suitable year round vegetative cover shall be maintained at all times, such that crop health is
optimized, allows for even distribution of effluent and allows inspection of the irrigation system.
4. Adequate measures shall be taken to prevent effluent ponding in or runoff from the irrigation sites
listed in Table 2 of Condition II.4.
5. Irrigation shall not be performed during inclement weather or when the ground is in a condition that
will cause ponding or runoff.
6. Only effluent from the Callahan residence at 3761 Mason Road, New Hill, NC shall be irrigated on
the sites listed in Table 2 of Condition I1.4.
7. No automobiles or machinery shall be allowed on the irrigation sites except during equipment
installation or while maintenance is being performed.
S. Public access to the irrigation sites and wastewater treatment facilities shall be prohibited. Fencing
shall be provided to prevent access to the irrigation site (minimum 2 -strand wire) and treatment units
shall be secured with locks on all tank accesses and control panels.
9. The residuals generated from the wastewater treatment facilities shall be disposed or utilized in
accordance with 15A NCAC 02T .1100.
10. Diversion or bypassing of untreated or partially treated wastewater from the treatment facilities is
prohibited.
11. Pump/dosing tanks shall have audible and visual alarms external to any structure.
12. Any excavation into bedrock shall be lined with a 10 millimeter (mm) synthetic liner.
13. A water -tight seal on all treatment/storage units or minimum of two feet protection from the 100 -year
flood plain elevation shall be provided.
14. The Permittee is responsible for the operation and maintenance of the entire treatment and disposal
system including, but not limited to, the following items:
WQ0010742 Version 3.0 Shell Version 141027 Page 3 of 6
a. The septic tank shall be checked annually and pumped out as needed. The septic tank effluent
filter shall be checked and cleaned at the same frequency as the septic tank.
b. The tablet chlorinator shall be checked weekly. Wastewater grade chlorine tablets (calcium
hypochlorite) shall be added as needed to provide proper chlorination. Pool chlorine tablets shall
not be used. [15 A NCAC 02T .0605 (1)]
c. The storage, pump, and alarm systems shall be inspected monthly. The scum layer shall be
removed at the same interval as the septic tank is cleaned out.
d. The system shall be inspected monthly to make certain of the proper operation of the spray heads,
that the system is free of leaks, that the vegetative growth allows a proper spray pattern, that the
soil is assimilating the disposed treated wastewater with no surface runoff, and that no
objectionable odors are being generated. [15A NCAC 02T ,0108(bKl)]
IV. MONITORING AND REPORTING RE UIREMENTS
V.
Any Division required monitoring (including groundwater, plant tissue, soil and surface water
analyses) necessary to ensure groundwater and surface water protection shall be established, and an
acceptable sampling reporting schedule shall be followed.
2. Noncompliance Notification:
The Permittee shall report by telephone to the Raleigh Regional Office, telephone number (919) 791-
4200, as soon as possible, but in no case more than 24 hours, or on the next working day following
the occurrence or first knowledge of the occurrence of any of the following:
a. Any process unit failure (e.g., mechanical, electrical, etc.), due to known or unknown reasons,
rendering the facility incapable of adequate wastewater treatment.
b. Any facility failure resulting in a by-pass directly to receiving surface waters.
c. Any time self-monitoring indicates the facility has gone out of compliance with its permit
limitations.
d. Ponding in or runoff from the irrigation sites.
Any emergency requiring immediate reporting (e.g., discharges to surface waters, imminent failure of
a storage structure, etc.) outside normal business hours shall be reported to the Division's Emergency
Response personnel at telephone number (800) 662-7956, (800) 858-0368, or (919) 733-3300.
Persons reporting such occurrences by telephone shall also file a written report in letter form within
five days following first knowledge of the occurrence. This report shall outline the actions taken or
proposed to be taken to ensure the problem does not recur.
1. The Permittee shall provide adequate inspection and maintenance to ensure proper operation of the
wastewater treatment and irrigation facilities.
2. The Permittee or their designee shall inspect the wastewater treatment and irrigation facilities to
prevent malfunctions, facility deterioration and operator errors resulting in discharges, which may
cause the release of wastes to the environment, a threat to human health or a public nuisance. The
Permittee shall maintain an inspection log that includes, at a minimum, the date and time of
inspection, observations made, and any maintenance, repairs, or corrective actions taken. The
Permittee shall maintain this inspection log for a period of five years from the date of the inspection,
and this log shall be made available to the Division upon request.
WQ0010742 Version 3.0 Shell Version 141027 Page 4 of 6
3. Any duly authorized Division representative may, upon presentation of credentials, enter and inspect
any property, premises or place on or related to the wastewater treatment and irrigation facilities
permitted herein at any reasonable time for the purpose of determining compliance with this permit;
may inspect or copy any records required to be maintained under the terms and conditions of this
permit, and may collect groundwater, surface water or Leachate samples.
VI. GENERAL CONDITIONS
1. Failure to comply with the conditions and limitations contained herein may subject the Permittee to
an enforcement action by the Division in accordance with North Carolina General Statutes 143-
215.6A to 143-215.6C.
2. This permit shall become voidable if the permitted facilities are not constructed in accordance with
the conditions of this permit, the Division approved plans and specifications, and other supporting
documentation.
3. This permit is effective only with respect to the nature and volume of wastes described in the permit
application, Division approved plans and specifications, and other supporting documentation. No
variances to applicable rules governing the construction or operation of the permitted facilities are
granted, unless specifically requested and approved in this permit pursuant to 15A NCAC 02T
.0105(n).
4. The issuance of this permit does not exempt the Permittee from complying with any and all statutes,
rules, regulations, or ordinances, which may be imposed by other jurisdictional government agencies
(e.g., local, state, and federal). Of particular concern to the Division are applicable river buffer rules
in 15A NCAC 02B .0200; erosion and sedimentation control requirements in 15A NCAC Chapter 4
and under General Permit NCG010000; any requirements pertaining to wetlands under 15A NCAC
02B .0200 and 02H .0500; and documentation of compliance with Article 21 Part 6 of Chapter 143 of
the General Statutes.
5. In the event the permitted facilities change ownership or the Permittee changes their name, a formal
permit modification request shall be submitted to the Division. This request shall be made on official
Division forms, and shall include appropriate property ownership documentation and other supporting
documentation as necessary. The Permittee of record shall remain fully responsible for maintaining
and operating the facilities permitted herein until a permit is issued to the new owner.
6. The Permittee shall retain a set of Division approved plans and specifications for the life of the
facilities permitted herein.
7. The Permittee shall maintain this permit until all permitted facilities herein are properly closed or
permitted under another permit issued by the appropriate permitting authority pursuant to 15A NCAC
02T .01050.
8. This permit is subject to revocation or unilateral modification upon 60 days notice from the Division
Director, in whole or part for the requirements listed in 15A NCAC 02T .0110.
9. Unless the Division Director grants a variance, expansion of the permitted facilities contained herein
shall not be granted if the Permittee exemplifies any of the criteria in 15A NCAC 02T .0120(b).
W Q00 10742 Version 3.0 Shell Version 141027 Page 5 of 6
10. The Permittee shall pay the annual fee within 30 days after being billed by the Division. Failure to
pay the annual fee accordingly shall be cause for the Division to revoke this permit pursuant to 15A
NCAC 02T .0105(e)(3).
Permit issued this the 12'' day of December 2014
NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION
oma . Reeder, Director
Divis' n of Water Resources
By Authority of the Environmental Management Commission
Permit Number WQ0010742
WQ0010742 Version 3.0 Shell Version 141027 Page 6 of 6
State of North Carofina
Department of Environment and Natural Resources
Division of Water Resources
15A NCAC 02T.0600 — SINGLE-FAMILY RESIDENCE WASTEWATER IRRIGATION SYSTEMS
OPFR_ATION AND MAINTENANCE AGREEMENT
Division of Water Resources FORM: SFRWWIS O&M 08-13
Permit No. �' V
a
Property owner(s) as appearing on the recorded deed:
Mailing address: r � �� lti
Facility address:
Irrigation Method: SPRAY ❑ DRIP
County: 1A�1 •'
::YAlvt f"�.
IIAgAt'i
I / We agree to operate and maintain the single-family residence wastewater treatment and irrigation system as follows:
1. The Permittee is responsible for the operation and maintenance of the entire wastewater treatment and irrigation
system including, but not limited to, the following items:
a. The septic tank shall be checked annually and pumped out as needed.
b. The septic, tank effluent filter shall be checked and cleaned annually.
c. Accessible sand filter surfaces shall be raked and leveled every six months and any vegetative growth shall be
removed manually.
d. The tablet chlorinator shall be checked weekly. Wastewater grade tablets (calcium hypochlorite) shall be
added as needed to provide proper chlorination (pool chlorine tablets shall not be used), OR
�; ❑ The ultraviolet disinfection unit shall be checked weekly" The lamp(s) and quartz sleeve(s) shall be
�., cleaned or replaced as needed to ensure proper disinfection. r*K
3: m
e. All pump and alarm systems shall be inspected monthly. Q c o a
f. The irrigation system shall be inspected monthly.to ensure that the system is free of leaks, that all i tion U)
equipment is operating as designed, that vegetative gbrowth does not interfere with the system inspefti n o Z
Co 0
operation, that the soil is assimilating the disposed treated wastewater with no visible runoff or pond and_
that no objectionable odors are being generated. C-)_
L
LU
4 (�
2. Failure to pay the annual fee shall be cause for the Division to revoke the permit pursuant to 15A NCA2 02T 3 Q
.0105(e)(3). Q::_
3" The Permittee's failure to properly operate this system is subject to a penalty up to $25,000 per day. cz
4. Failure to meet the permit conditions or violation of the State's surface water or groundwater regulations maid
the permit.`
1 owners appearing on the legally recorded property deed shall sign this Operation & Maintenance Agree t
1 / We understand the above requii
t ,
Owner Signature: ! i
Owner Signature:
FORM: SFRWWIS O&M 08J3
and,agre i -to these terms as part of the issued pen -nit.
Date
L
Date: 4 1`
i 1 Lf
i L
Page Ioft