Loading...
HomeMy WebLinkAboutWQ0008778_Compliance_19981117Is ` State of North Carolina Department of Environmentand Natural Resources Division of Water Quality James B. Hunt, Jr., Governor Wayne McDevitt, Secretary. _ A. Preston Howard, Jr., P.E., Director A W_WJW . 0 6, NCDENR NoRTH CARo-INA DEPARTMENT of ENVIRONMENT AND NnruRAL REsouRCEs November 17, 1998 RICHARD N. HICKS FARMViLLE, TOWN-BIOSOLIDS PO BOX 86 FARMVILLE, NC 27828 Subject: Specific Oxygen Uptake Rate Testing Compliance Land Application of Residuals Permit Number: WQ0008778 PITT County Dear Sir. The Division has noted in several Annual Reports that the Specific Oxygen Uptake Rate (SOUR) test has been improperly used for proof of compliance with the Vector Attraction Reduction (VAR) requirements of 40 CFR 503. Currently, the SOUR test may only be used if all of the following conditions are met: 1. Percent Total Dry Solids. The residual must be less than 2 percent total dry solids. Diluting thickened sludges is not acceptable. 2. Temperature Range. The SOUR may only be applied to sludges which are at temperatures between 10°C and 30'C., 3. Temt)erature Correction. The SOUR test must be conducted at the same temperature that the digester is operating. The SOUR test must be temperature corrected to an equivalent 20°C value. The temperature correction equation is as follows: SOURIo= SOURS x eczan where: T = sludge temperature in degrees Celsius 0 = 1.05 above 20°C e =1.07 below 20°C 4. :Continuous Aeration. The SOUR test may only be used on sludges which have been stabilized in aerobic - environments. Sludge holding tanks which are used primarily for sludge gravity thickening and only periodically aerated to minimize odor generation may not use the SOUR test to indicate compliance with the VAS requirements. 5. '.Sample Holding Time. The maximum holding time is two hours. If the SOUR test cannot be completed within 15 minutes of sampling, then the sample must be maintained under aeration until the test can be completed..: P.O. Box 29535, Raleigh, North Carolina 27626-0535 Telephone 919-733-5083 Fax 919-715-6048 An Equal Opportunity Affirmative Action Employer 5017,7 recycled/10% post -consumer paper r F .. Specific Oxygen Uptake Rate Testing Compliance Permit Number. WQ0008778 Page 2. 6. _Testing Frequency andArithmeticMean Compliance. Variability in digester detention times, operating temperatures, and sludge characteristics results in variability in SOUR test results for afacility during the operating year. For VAR compliance purposes, the arithmetic mean of SOUR data from seven samples taken periodically during the monitoring period specified in your permit will be considered sufficient. For facilities using aerobic digestion for sludge stabilization, the Division suggests that Vector Attraction Reduction compliance be indicated by calculation of a volatile solids reduction percentage of 38 percent or more in accordance with 40 CFR 503.33 (b)(1). If compliance cannot be shown by calculation of Volatile Solids Reduction, then the SOUR test may be used only if the requirements listed above are met. If both the 38 percent volatile solids reduction cannot be met and the SOUR test is not valid, then the permittee must use an alternative vector attraction reduction technique, such as the bench -scale extended aerobic digestion test - 40 CFR 503.33(b)(3). The Division encourages you to immediately review your method of meeting the vector attraction reduction requirement, and to take action to ensure you provide valid proof that your sludge has met the requirements of 40 CFR 503 for the 1997 year. These requirements are being enforced by both the Division of Water Quality and USEPA Region 4 until the Division of Water Quality is delegated authority for the 40 CFR 503 program. Attached please find a copy of the most current standard method and an example of a SOUR test form with calculations. If you have any questions, .regarding these tests you are encouraged to contact Kevin Barnett with the Division of Water Quality at (919)733-5083 ext. 529. Sincerely, Dennis R_ Ramsey, P.E. Assistant Chief for Non -Discharge Cc: Non -Discharge Compliance 1 Enforcement Unit Non -Discharge Permitting Unit _ Washington Regional Supervisor �y Training and Certification Unit Central Files MadoIyn S. Dominy, EPA Region 4 �' av CE�7RAL FILES