HomeMy WebLinkAboutWQ0006552_Final Permit_19970310State of North Carolina Department of Environment, Health and Natural Resources Division of Water Quality James B. Hunt, Jr., Governor Jonathan B. Howes, Secretary A. Preston Howard, Jr., P.E., Director Mr. John Hubbard, Plant manager, Georgia-Pacific Corporation 120 Warren Road Bowdens, North Carolina 28398 Dear Mr. Hubbard: A N1.K?FA [DEHNR March 10, 1997 Subject: Permit No. WQ0006552 Georgia-Pacific Corporation Bowdens Sawmill, Wet Deck & Vehicle Wash Wastewater Recycle Systems Duplin County In accordance with your application received December 18, 1996, we are forwarding herewith Permit No. WQ0006552 dated March 10, 1997, to Georgia-Pacific Corporation for the continued operation of the subject wastewater recycle systems. Please note, in accordance with your request, Permit No. WQ0008884, vehicle wash recycle system, is now combined with this permit. Please be informed that upon issuance of this permit, Permit No. WQ0008884 issued April 19, 1994, is hereby rescinded. This permit shall be effective from the date of issuance until February 28, 2002, shall void Permit No. WQ0006552 issued September 24, 1992, and shall be subject to the conditions and limitations as specified therein. Please pay particular attention to the monitoring requirements in this permit. Failure to establish an adequate system for collecting and maintaining the required operational information will result in future compliance problems. If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within thirty (30) days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 150B of North Carolina General Statutes, and filed with the Office of Administrative Hearings, P.O. Drawer 27447, Raleigh, NC 27611-7447. Unless such demands are made this permit shall be final and binding_ If you need additional information concerning this matter, please contact Mr. John Seymour :at (919) 733-5083 extension 546. Sincerely, A. Preston Howard, Jr., P.F. cc: Duplin County Health Department Mr. Stanley K. Ricker, Georgia-Pacific Corporation Environmental Engineering Wilmington Regional Office, Water Quality Section Training and Certification Unit Facilities Assessment Unit P.O. Box 29535, Raleigh, North Carolina 27626-0535 Telephone (919) 733-5083 FAX (919) 733-0719 An Equal Opportunity Affirmative Action Employer 50% recycled/ 10% post -consumer paper NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT OF ENVIRONMENT, HEALTH AND NATURAL RESOURCES RALEIGH RECYCLE SYSTEM PERMIT In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations PERMISSION IS HEREBY GRANTED TO Georgia-Pacific Corporation Duplin County FOR THE continued operation of a 0.3 MGD wastewater recycle system consisting of two settling ponds, dual 200 GPM irrigation pumps, a water supply well and all associated piping, valves, sprinklers, controls and appurtenances to serve the Bowdens, N.C. Saw Mill Wet Deck; and the continued operation of a 350 GPD wastewater recycle system consisting of a covered concrete slab with a sump pit, an RGF Ultrasorb Model LD multi -component recycling system, a 550 gallon storage tank, a 30 gallon pressure tank, and all associated piping, valves, controls and appurtenances to serve the Bowdens, N.C. Saw Mill Vehicle Wash; with no discharge of wastes to the surface waters, pursuant to the application received December 18, 1996, and in conformity with the project plan, specifications, and other supporting data subsequently filed and approved by the Department of Environment, Health and Natural Resources and considered a part of this permit. This permit shall be effective from the date of issuance until February 28, 2002 shall void Permit No. WQ0006552 issued September 24, 1992, and shall be subject to the following specified conditions and limitations: This permit shall become voidable unless the facilities are constructed in accordance with the conditions of this permit, the approved plans and specifications, and other supporting data. 2. This permit is effective only with respect to the nature and volume of wastes described in the application and other supporting data. 3. The facilities shall be properly maintained and operated at all times. 4. This permit is not transferable. In the event there is a desire for the facilities to change ownership, or there is a name change of the Permittee, a formal permit request must be submitted to the Division of Water Quality accompanied by an application fee, documentation from the parties involved, and other supporting materials as may be appropriate. The approval of the request will be considered on its merits and may or may not be approved. 5. In the event that the facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those actions that may be required by this Division, such as the construction of additional or replacement treatment or disposal facilities. 6. The residuals generated from these treatment facilities must be disposed in accordance with General Statute 143-215.1 and in a manner approved by the North Carolina Division of Water Quality. 7. The issuance of this permit shall not relieve the Permittee of the responsibility for damages to surface or groundwaters resulting from the operation of this facility. 8. The facilities shall be effectively maintained and operated as a non -discharge system to prevent the discharge of any wastewater resulting from the operation of this facility. 9. Diversion or bypassing of untreated wastewater from the treatment facilities is prohibited. 10. Freeboard in the wet deck settling ponds shall not be less than two feet at any time. 11. Any monitoring deemed necessary by the Division of Water Quality to insure surface and ground water protection will be established and an acceptable sampling reporting schedule shall be followed. 12. Adequate inspection, maintenance, and cleaning shall be provided by the Permittee to insure proper operation of the subject facilities. 13. The Permittee or his designee shall inspect the wastewater recycle facilities to prevent malfunctions and deterioration, operator errors and discharges which may cause or lead to the release of wastes to the environment, a threat to human health, or a nuisance. The Permittee shall maintain an inspection log or summary including at least the date and time of inspection, observations made, and any maintenance, repairs, or corrective actions taken by the Permittee. This log of inspections shall be maintained by the Permittee for a period of three years from the date of the inspection and shall be made available to the Division of Water Quality or other permitting authority, upon request. 14. Any duly authorized officer, employee, or representative of the Division of Water Quality may, upon presentation of credentials, enter and inspect any property, premises or place on or related to the recycle system at any reasonable time for the purpose of determining compliance with this permit, may inspect or copy any records that must be maintained under the terms and conditions of this permit, and may obtain samples of groundwater, surface water, or leachate. 15. The annual administering and compliance fee must be paid by the Permittee within thirty (30) days after being billed by the Division. Failure to pay the fee accordingly may cause the Division to initiate action to revoke this permit as specified by 15A NCAC 2H .0205 (c)(4)• 16. Failure to abide by the conditions and limitations contained in this permit may subject the Permittee to an enforcement action by the Division of Water Quality in accordance with North Carolina General Statute 143-215.6(a) to 143-215.6(c). 17. The issuance of this permit does not preclude the Permittee from complying with any and all statutes, rules, regulations, or ordinances which may be imposed by other government agencies (local, state, and federal) which have jurisdiction. 18. A set of approved plans and specifications for the subject project must be retained by the Permittee for the life of this project. M 19. Noncompliance Notification: The Permittee shall report by telephone to the Wilmington Regional Office, telephone number 910/ 395-3900 as soon as possible, but in no case more than 24 hours or on the next working day following the occurrence or first knowledge of the occurrence of any of the following: a. Any occurrence at the wastewater treatment facility which results in the treatment of significant amounts of wastes which are abnormal in quantity or characteristic, such as the dumping of the contents of a basin or tank, the known passage of a slug of hazardous substance through the facility, or any other unusual circumstances; b. Any process unit failure, due to known or unknown reasons, that renders the facility incapable of adequate wastewater treatment, such as mechanical or electrical failures of pumps, aerators, compressors, etc.; c. Any failure of a pumping station, sewer line, or treatment facility resulting in a by-pass directly to receiving waters without treatment of all or any portion of the influent to such station or facility; or d. Any time that self -monitoring information indicates that the facility is not in compliance with its permit limitations. Persons reporting such occurrences by telephone shall also file a written report in letter form within five (5) days following first knowledge of the occurrence. This report must outline the actions taken or proposed to be taken to ensure that the problem does not recur. 20. Upon classification of the facility by the Certification Commission, the Permittee shall employ a certified wastewater treatment plant operator to be in responsible charge (ORC) of the wastewater treatment facilities. The operator must hold a certificate of the type and grade at least equivalent to or greater than the classification assigned to the wastewater treatment facilities by the Certification Commission. The Permittee must also employ a certified back-up operator of the appropriate type and grade to comply with the conditions of Title 15A, Chapter 8A, .0202. The ORC of the facility must visit each Class I facility at least weekly and each Class II, III, and IV facility at least daily, excluding weekends and holidays, and must properly manage and document daily operation and maintenance of the facility and must comply with all other conditions of Title 15A, Chapter 8A, .0202. 21. The Permittee, at least six (6) months prior to the expiration of this permit, shall request its extension. Upon receipt of the request, the Commission will review the adequacy of the facilities described therein, and if warranted, will extend the permit for such period of time and under such conditions and limitations as it may deem appropriate. 22. Upon permit issuance, the Bowdens, N.C. Saw Mill Vehicle Wash facilities are added to this permit, and Permit No. WQ0008884 issued. April 19, 1994, is hereby rescinded. Permit issued this the loth day of March, 1997 NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION A Preston Howard, Jr., P.E., Director Division of Water Quality By Authority of the Environmental Management Commission Permit Number WQ0006552 - ,_ f 120 .iaasa r Ili, t � f ... •�- / ;. �� �2577 eR roaqb ' 1 117 _� - '.� rr ��� �� ���_ `` � �\ � fib _ Q • Ela 3e$5 • � ?i L41YDIARFffRlP � � � _ _ �.� � - / `. '- .. •, - l60 � c \r_J S dpit�s YS�ndoit�'`` { N�Georgia-Pacific Corporation 1 '~--��\ --Nondis. No. WQ0006552 - _ = Latitude: 35 ° 03' 32" - Lonj�,itude: 780 07' 05" " '_'� • � _ - a. •i Cam "� a aA}I Creek i II I< . Watery I. Tank ri i `hem /^` G�ommunisv • DOWdeTL V. 83 Macedonia cli 3882 2'30,, lgg .,' 157 -- •'EEr _� -. 11342 II Cern .y�=mil \�, o ! ! •; '� ''a ., l l'lf �'r` " ., • / �a=dam. 6M ef�� 143 r RATING SCALE FOR CLASSIFICATION OF WATER POLLUTION CONTROL SYSTEMS Name of Facility:. Geo,ra;c, Petc;- �Lc(4 W<j4dQ,.k Owner or Contact Person: MA. Torn i3 G �✓oi___ Mailing Address: I z_ a R_d s (3o wden 5 Alc- Z S 3 21 8 County: 1Ju i; Telephone:_ L old) Z53-3 !-3 Present Classification: New Facility Existing Facillty ✓ NPDES Per. No. NC00 Nondisc. Per. No.WO bo o'S Health Dept Per No. Rated by: vss Ca !bv _ Telephone: C � it 3 S- 3 Sao Date: 2/ j!/ IF Reviewed by: Health Dept. Telephone: Regional Office Central Office ORC: Grade: Check Classification(s): Subsurface Spray Irrigation Wastewater Classification: (Circle One) 6 it III IV Telephone: Telephone: Telephone: _ Land Application Total Points: I►�SI:1►1�'Ct1►. :►� i :l /►Ilwl� wli `u�►1 al�.� :i a \il...C: �:tl !a ►� li: rili� 1•i► ~�: \� il�� 1 i . � 1 L r la : hi �\I ��i 1 i i'A !� � �..: *► ;.,_ ! Jtl� lii �! i \. �L' ! sJ�. Jim SUBSURFACE CLASSIFICATION (check all units that apply) 1. septic tanks 2. pump tanks 3. siphon or pump -dosing systems 4. sand filters 5. grease trapAnterceptor 6. oillwater separators 7. gravity subsurface treatment and disposal: 8. pressure subsurface treatment and disposal: SPRAY IRRICATICN CtASS4FICATION (check all units that apply) 1. preliminary treatment (definition no, 32 ) 2. lagoons 3. septic tanks 4. pump tanks 5. pumps 6. sand filters 7. grease trapinterceptor 8. cillwater separators 9. disinfection 10. chemical addition for nuirientlalgae control 11. spray irrigation of wastewater In addition to the above classifications, pretreatment of wastewater In excess of these components shell be rated using the point rating system and will require an operator with an appropriate dual certification. LAND APALICATfON/RESIDUALS CLASSIFICATION (Applies only to permit holder) 1. Land application of biosolids, residuals or contaminated soils on a designated site. WASTEWATER TREATMENT FACILITY CLASSIFICATION The following systems shall be assigned a Class I classification. Unless the flow is of a significant quantity or the technology is unusually complex, to require consideration by the Commission on a case -by -case basis: (Check K Appropriate) 1. 011wwater -separator Systems consisting only of physical separation, pumps and disposal; 2. Septic Tank/Sand Filter Systems consisting only of septic tanks, dosing apparatus, pumps,sand filters, disinfection and direct discharge; 3. Lagoon Systems consisting only of preliminary treatment, lagoons, pumps, disinfection, necessary chemical treatment for algae or nutrient control, and direct discharge; 4. ✓ Closed -loop Recycle Systems; 5. Groundwater Remediation Systems consisting only of oil/water separators, pumps, air -stripping, carbon adsorption, disinfecien and disposal; 6. Aquaculture operations with discharge to surface waters; 7. Water Plant sludge handling and back -wash water treatment; 8. Seafood processing consisting of screening and disposal_ 9. Single-family discharging systems, with the exception of Aerobic Treatment Units, will be classified if permitted after July 1, 1993 or if upon inspection by the Division, it is found that the system is not being adequately operated or maintained. Such systems will be notified of the classification or reclassification by the Commission, in writing.