HomeMy WebLinkAboutWQ0006255_Final Permit_19920716State of North Carolina
Department of Environment, Health and Natural Resources
Division of Environmental Management
512 North Salisbury Street • Raleigh, North Carolina 27611
James G. Martin, Governor
William W. Cobey, Jr., Secretary
A. Preston Howard, Jr., P.E.
Acting Director
July 16, 1992
Mike Stegall, President
T.G. Stegall Trucking Company, Inc.
P.O. Box 98
Matthews, N.C. 28106
Subject: Permit No. WQ0006255
T.G. Stegall Trucking Company, Inc.
Truck Wash Facilities
Subsurface Disposal System
Mecklenburg County
Dear Mr. Stegall:
In accordance with your application received March 13, 1992, we are forwarding herewith Permit
No. WQ0006255, dated July 16, 1992, to T.G. Stegall Trucking Company, Inc. for the continued
operation of a 1,000 GPD subsurface wastewater disposal system.
This permit shall be effective from the date of issuance until June 30, 1997, and shall void Permit
No. 15436 issued December 2, 1987 and shall be subject to the conditions and limitations as specified
therein. Please pay particular attention to the monitoring requirements in this permit. Failure to establish an
adequate system for collecting and maintaining the required operational information will result in future
compliance problems.
If any parts, requirements, or limitations contained in this permit are unacceptable to you, you have
the right to request an adjudicatory hearing upon written request within 30 days following receipt of this
permit. This request must be in the form of a written petition, conforming to Chapter 150B of North
Carolina General Statutes, and filed with the Office of Administrative Hearings, P.O. Drawer 27447,
Raleigh, NC 27611-7447. Unless such demands are made this permit shall be final and binding.
Regional Offices
Asheville Fayetteville Mooresville Raleigh Washington Wilmington Winston-Salem
704/251-6208 9191486-1541 704/663-1699 919/733-2314 919/946-6481 919/395-3900 919/761-2351
Pollution Prevention Pays
P.O. Box 29535, Raleigh, North Carolina 27626-0535 Telephone 919-733-7015
An Equal Opportunity Afi-irmative Action Employer
If you need additional information concerning this matter, please contact W,. Michael D. Allen at
(919) 733-5083.
Si
A. Preston owaid, Jr. P
cc: Mecklenburg County Health Department
Mooresville Regional Office, Water Quality
Mooresville Regional Office, Groundwater
Groundwater Section, Jack Floyd
Training and Certification Unit
NORTH CAROLINA
ENVIRONMENTAL MANAGEMENT COMMISSION
DEPARTMENT OF ENVIRONMENT, HEALTH AND NATURAL RESOURCES
RALEIGH
SUBSURFACE DISPOSAL SYSTEM PERMIT
In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina
as amended, and other applicable Laws, Rules, and Regulations
PERMISSION IS HEREBY GRANTED TO
T.G. Stegall Trucking Company, Inc.
Mecklenburg County
FOR THE
continued operation of a 1,000 GPD subsurface wastewater disposal system consisting of a 1,000 gallon
oil/water separator, two 1,500 gallon holding tanks, and a 12,500 square foot nitrification field consisting
of twelve 100 feet drain lines to serve T.G. Stegall Trucking Company, Inc. with no discharge of wastes
to the surface waters, pursuant to the application received March 13, 1992 and in conformity with the
project plan, specifications, and other supporting data subsequently filed and approved by the Department
of Environment, Health and Natural Resources and considered a part of this permit.
This permit shall be effective from the date of issuance until June 30, 1997, and shall void Permit
No. 15436 issued December 2, 1987 and shall be subject to the following specified conditions and
limitations:
•�u 1 -3110
1. In the event that the facilities fail to perform satisfactorily, including the creation of
nuisance conditions, the Permittee shall take immediate corrective action, including those
as may be required by this Division, such as construction of additional or replacement
wastewater treatment or disposal facilities.
2. The issuance of this permit shall not relieve the Permittee of the responsibility for damages
to surface or groundwaters resulting from the operation of this facility.
3. This permit shall become voidable if the soils fail to adequately absorb the wastes and may
be rescinded unless the facilities are installed, maintained, and operated in a manner which
will protect the assigned water quality standards of the surface waters and ground waters.
4. Adequate measures shall be taken to divert stormwater from the disposal area and prevent
wastewater runoff from the subsurface disposal field.
5. The sludge generated from these treatment facilities must be disposed of in accordance with
General Statute 143-215.1 and in a manner approved by the North Carolina Division of
Environmental Management.
b. A usable reserve area shall be maintained for wastewater disposal. The reserve area shall
have the capability of accommodating the average daily flow of the facility being served
without exceeding the loading rates of the reserve area while meeting all required buffer
requirements.
7. Diversion or bypassing of the untreated wastewater from the treatment facilities is
prohibited. ,
8. The following buffers shall be maintainedt:
a) 100 feet between disposal area and any public or private water supply including
wells
b) 100 feet between disposal area and "SA and SB" classified surface waters
c) 50 feet between disposal area and any stream, lake, river or natural drainageway
d) 50 feet between disposal area and property lines
e) 10 feet between disposal area and surface water interceptor drains or diversions
(upslope)
f) 25 feet between disposal area and surface water interceptor drains or diversions
(downslope) and groundwater drainage systems.
t - These buffers were not included in previous permits for this waste treatment and
disposal system. Therefore, they are not intended to require modification of existing
facilities to obtain compliance. They do however apply to any modification of the
waste treatment facilities, any new construction within the area of influence of these
buffers, and the sale of property that would cause any of the buffers now complied
with to be violated.
II. OPERATION AND MAINTENANCE -REQUIREMENTS
1. The facilities shall be properly maintained and operated at all times.
2. Upon classification of the facility by the Certification Commission, the Permittee shall
employ a certified wastewater treatment plant operator to be in responsible charge (ORC) of
the wastewater treatment facilities. The operator must hold a certificate of the type and
grade at least equivalent to or greater than the classification assigned to the wastewater
treatment facilities by the Certification Commission. The Permittee must also employ a
certified back-up operator of the appropriate type and grade to comply with the conditions
of Title 15A, Chapter 8A, .0202. The ORC of the facility must visit each Class I facility at
least weekly and each Class II, III, and IV facility at least daily, excluding weekends and
holidays, and must properly manage and document daily operation and maintenance of the
facility and must comply with all other conditions of Title 15A, Chapter 8A, .0202.
3. The facilities shall be effectively maintained and operated as a non -discharge system to
prevent the discharge of any wastewater resulting from the operation of this facility.
4. No traffic or equipment shall be allowed on the disposal area except while installation
occurs or while normal maintenance is being performed.
5. A suitable cover shall be maintained on the LPP field(s) and the field(s) shall be routinely
mowed. The clippings shall be periodically removed to prevent the build-up of thatch.
2
I . Any monitoring deemed necessary by the Division of Environmental Management to insure
surface and ground water protection will be established and an acceptable sampling
reporting schedule shall be followed.
2. A record shall be maintained of all residuals removed from this facility.. This record shall
include the name of the hauler, permit authorizing the disposal or a letter from a
municipality agreeing to accept the residuals, date the residuals were hauled, and volume of
residuals removed.
3. Non compliance__Not_ification:
The Permittee shall report by telephone to the Mooresville Regional Office, telephone no.
(704) 663-1699 as soon as possible, but in no case more than 24 hours or on the next
working day following the occurrence or first knowledge of the occurrence of any of the
following:
a. Any occurrence at the wastewater treatment facility which results in the treatment of
significant amounts of wastes which are abnormal in quantity or characteristic, such
as the dumping of the contents of a basin or tank; the known passage of a slug of
hazardous substance through the facility; or any other unusual circumstances.
b. Any process unit failure, due to known or unknown reasons, that render the facility
incapable of adequate wastewater treatment such as mechanical or electrical failures
of pumps, aerators, compressors, etc.
C . Any failure of a pumping station, sewer line, or treatment facility resulting in a by-
pass of all or any portion of the influent to such station or facility.
d. Any time that self-monitoring information indicates that the facility has gone out of
compliance with its pen -nit limitations.
Persons reporting such occurrences by telephone shall also file a written report in letter
form within 15 days following first knowledge of the occurrence_ This report must outline
the actions taken or proposed to be taken to ensure that the problem does not recur.
IV. CIRQUNDWATER REQUIREMENTS
Any groundwater quality monitoring as deemed necessary by the Division of
Environmental Management shall be provided.
2. Within 45 days of permit reissuance, all floor drains shall be abandoned in accordance with
40 CFR 144.12.
V. INSPECTIQNS
Adequate inspection, maintenance, and cleaning shall be provided by the Permittee to
insure proper operation of the subject facilities.
3
2. The Permittee or his designee shall inspect the wastewater treatment and disposal facilities
to prevent malfunctions and deterioration, operator errors and discharges which may cause
or lead to the release of wastes to the environment, a threat to human health, or a nuisance.
The Permittee shall keep an inspection log or summary including at least the date and time
of inspection, observations made, and any maintenance, repairs, or gorrective actions
taken by the Permittee. This log of inspections shall be maintained by the Permittee for a
period of three years from the date of the inspection and shall be made available upon
request to the Division of Environmental Management or other permitting authority.
3. Any duly authorized officer, employee, or representative of the Division of Environmental
Management may, upon presentation of credentials, enter and inspect any property,
premises or place on or related to the disposal site and facility at any reasonable time for the
purpose of determining compliance with this permit; may inspect or copy any records that
must be kept under the terms and conditions of this permit; or may obtain samples of
groundwater, surface water, or leachate.
V1. CzENERAL CONDITIONS
1. This permit shall become voidable unless the facilities are constructed in accordance with
the conditions of this permit, the approved plans, specifications and other supporting data.
2. This permit is effective only with respect to the nature and volume of wastes described in
the application and other supporting data.
3. This permit is not transferable. In the event there is desire for the facilities to change
ownership, or there is a name change of the Permittee, a formal permit request must be
submitted to the Division of Environmental Management accompanied by an application
fee, documentation from the parties involved, and other supporting materials as may be
appropriate. The approval of this request will be considered on its merits and may or may
not be approved.
4. The annual administering and compliance fee must be paid by the Permittee within thirty
(30) days after being billed by the Division. Failure to pay the fee accordingly may cause
the Division to initiate action to revoke this permit as specified by 15 NCAC 2H .0205
(c)(4).
5. Failure to abide by the conditions and limitations contained in this permit may subject the
Permittee to an enforcement action by the Division of Environmental Management in
accordance with North Carolina General Statute 143-215.6A to 143-215.6C.
6. The subject wastewater treatment and disposal facilities shall be connected to an operational
publicly owned wastewater collection system within 180 days of its availability to the
subject facilities, if the subject wastewater treatment or disposal facilities are in
noncompliance with the terms and conditions of this non -discharge permit or the governing
statutes or regulations.
Prior to the initiation of these connection activities, appropriate approval must be received
from this Division.
7. The issuance of this permit does not preclude the Permittee from complying with any and
all statutes, rules, regulations, or ordinances which may be imposed by other government
agencies (local, state, and federal) which have jurisdiction.
4
8. The Permittee, at least six (6) months prior to the expiration of this permit, shall request its
extension. Upon receipt of the request, the Commission will review the adequacy of the
facilities described therein, and if warranted, will extend the permit for such period of time
and under such conditions and limitations as it may deem appropriate.
Permit issued this the 16th day of July, 1992
NORTH
A. Preston Hom
Division of Envi
By Authority of
Permit No. WQ0006255
Jr."' PR
MANAGEMENT COMMISSION
Management Commission
W
awmu
` c
G
orf �
600
6
704
\C ,.
� ♦i
ti.
•1480 000 FEET 525
and published by the Geological Survey
)SINOAA, and Horth Carolina Geodetic Survey
,ogrammetric methods from aerial photographs
I checked 1971
r 1,
40
Y
,
Su ~ �~ r•
�_�� PINEV7LLs !3'MF. rns
1526
�2r30n MOHROE 14 Mf.
WAD.ESBORO 33 Mf. SC.�
+� rvoo 0
lap 2000
5
GM 1
ani• CONTOUR 1
n•,�. NATIONAL GEODETI
State of North Carolina
Department of Environment, Health and Natural Resources
Division of Environmental Management
512 North Salisbury Street • Raleigh, North Carolina 27611
James G. Martin, Governor A. Preston Howard, Jr., P.E.
William W. Cabey, Jr., Secretary Acting Director
MEMORANDUM
To: Training and Certification
From: iIQA BcI_QCPJ State Engineering Review Group
Subject: Rating Sheet for Permit Number l�G?oc.�Co2
Date: 15-9z
The subject permit is a renewal of Permit Number 15 +3 , , issued I z-Z-�,'7 , therefore, a
new rating sheet is not required. The existing rating is unchanged.
Regional Offices
Asheville Fayetteville Mooresville Raleigh Washington Wilmington Winston-Salem
704/251-6208 919/486-1541 704/663-1699 919/733-2314 919/945-6481 919/395-3900 9191896-7007
Pollution Prevention Pays
P.O. Box 29535, Raleigh, North Carolina 27626-0535 Telephone 919-733-7015
An Equal Opportunity Affirmative Action Employer