Loading...
HomeMy WebLinkAboutWQ0005681_Final Permit_20150827AMA. NCDENR North Carolina Department of Environment and Natural Resources Pat McCrory Donald R. van der Vaart Governor Secretary August 27, 2015 BRUCE J. MORGAN — MANAGER OF WATER & WASTEWATER PILGRIM'S PRIDE CORPORATION 484 ZIMMERMAN ROAD SANFORD, NORTH CAROLINA 27330 Subject: Permit No. WQ0005681 Staley Hatchery & Feed Mill Wastewater Irrigation System Randolph County Dear Mr. Morgan: In accordance with your permit renewal request received April 13, 2015, we are forwarding herewith Permit No. WQ0005681 dated August 27, 2015, to Pilgrim's Pride Corporation for the continued operation of the subject wastewater treatment and irrigation facilities. Please note that this renewed permit shall become effective on November 1, 2015 (i.e. the day after the expiration date of the existing permit). The modifications to the subject permit are as follows: The wetted area listed on Attachment B has been refined to more accurately reflect the actual wetted area of 6.27 acres. Effluent sampling has been expanded to include Total Kjeldahl Nitrogen, Nitrate Nitrogen, and Total Residual Chlorine. The groundwater monitoring parameters of pH (PCS Code 00403) has been changed to pH (PCS Code 00400), and Volatile Compounds have been removed from; the list of groundwater monitoring parameters because they have not been historically detected. This permit shall be effective from November 1, 2015 until October 31, 2020, shall void Permit No. WQ0005681 issued December 20, 2011, and shall be subject to the conditions and limitations as specified therein. Please pay particular attention to the monitoring requirements listed in Attachments A, B and C for they may differ from the previous permit issuance. Failure to establish an adequate system for collecting and maintaining the required operational information shall result in future compliance problems. For your convenience, customized electronic copies of your facility's NDMR and NDAR-1 reporting forms are available for download at: http://portal.ncdenr.org/web/wq/aps/lau/reporting. Please note the following permit conditions have been removed since the last permit issuance dated December 20, 2011: ➢ Old Condition 111.14. —This condition has been removed. Non -Discharge Permitting Unit 1617 Mail Service Center, Raleigh, North Carolina 27699-1617 Phone: 919-807-64641 Internet: http:lloortal,ncdenr.or.qlwebhxq An Equal Opportunity) Affirmative Action Employer — Made in part with recycled paper Mr. Bruce J. Morgan August 27, 2015 Page 2 of 2 Please note the following permit conditions are new or have been modified since the last permit issuance dated December 20, 2011: ➢ Condition 11.8. - Requires a permit modification for any property transfers affecting a compliance boundary. ➢ Condition 119. - Prohibits the construction of most wells inside of a compliance boundary. ➢ Condition 11.10. - Requires an easement for any property within the compliance boundary which is owned by others. ➢ Condition 11I.6. - Requires all irrigation equipment to be periodically tested and calibrated. ➢ Condition 111.13. - Requires staff gauges to be maintained for measuring water levels in the treatment lagoon and the storage pond. ➢ Condition IV.8. - Requires the recording of information for the removal of residuals. ➢ Condition IV.9. - Requires information to be included in the facility maintenance log. If any parts, requirements or limitations contained in this permit are unacceptable, the Permittec has the right to request an adjudicatory hearing upon written request within 30 days following receipt of this permit. This request shall be in the form of a written petition, conforming to Chapter 150B of the North Carolina General Statutes, and filed with the Office of Administrative Hearings at 6714 Mail Service Center, Raleigh, NC 27699-6714. Unless such demands are made, this permit shall be final and binding. If you need additional information concerning this permit, please contact David Goodrich at (919) 807- 6352 or by email at david.goodrich@ncdenr.gov. Sincerely, �4-S. Jay Zimmerman, P.G., Director Division of Water Resources cc: Randolph County Health Department (Electronic Copy) Winston-Salem Regional Office, Water Quality Regional Operations Section (Electronic Copy) Bob Branch, LSS - Branch Residuals & Soils, LLC (Electronic Copy) Central Files Digital Permit Archive (Electronic Copy) NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES RALEIGH WASTEWATER IRRIGATION SYSTEM PERMIT In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules and Regulations PERMISSION IS HEREBY GRANTED TO Pilgrim's Pride Corporation Randolph County FOR THE continued operation of a 13,000 gallon per day (GPD) wastewater treatment and irrigation facility consisting of. a 1,500 gallon lift station with two 25 galIon per minute (GPM) pumps and controls; a 2,000 gallon lift station with two 25 GPM pumps and controls; a 5,000 gallon aerated flow equalization tank with two 30 GPM pumps with controls; a package plant consisting of a 20,000 gallon aerated tank with diffusers, a 3,395 dual hopper clarifier, a 1,400 gallon sludge holding tank, and associated blowers, piping and controls; two tablet chlorinators; a 204,000 gallon treatment lagoon and a 204,000 gallon storage lagoon in series; a 6.27 acre spray irrigation area; and all associated piping, valves, controls and appurtenances to serve the Staley Hatchery & Feed Mill, with no discharge of wastes to surface waters, pursuant to the application received April 13, 2015, and in conformity with the project plans, specifications, and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources and considered a part of this permit. This permit shall be effective from November 1, 2015 until October 31, 2020, shall void Permit No. WQ0005681 issued December 20, 2011, and shall be subject to the following specified conditions and limitations: I. SCHEDULES No later than six months prior to the expiration of this permit, the Permittee shall request renewal of this permit on official Division forms. Upon receipt of the request, the Division will review the adequacy of the facilities described therein, and if warranted, will renew the permit for such period of time and under such conditions and limitations as it may deem appropriate. Please note Rule 15A NCAC 02T .0105(d) requires an updated site reap to be submitted with the permit renewal application. [15A NCAC 02T .0105(d), 02T .0106, 02T .0109, 02T .0115(c)] WQ0005681 Version 4.0 Shell Version 150213 Page 1 of 8 H. PERFORMANCE STANDARDS The subject non -discharge facilities shall be effectively maintained and operated at all times so there is no discharge to surface waters, nor any contravention of groundwater or surface water standards. In the event the facilities fail to perform satisfactorily, including the creation of nuisance conditions due to improper operation and maintenance, or failure of the irrigation areas to adequately assimilate the effluent, the Permittee shall take immediate corrective actions including Division required actions, such as the construction of additional or replacement wastewater treatment or irrigation facilities. [G.S. 143-215.1, 143-213.3(a)] 2. This permit shall not relieve the Permittee of their responsibility for damages to groundwater or surface water resulting from the operation of this facility. [ 15A NCAC 02B .0200, 02L .0100] 3. All wells constructed for purposes of groundwater monitoring shall be constructed in accordance with 15A NCAC 02C .0108 (Standards of Construction for Wells Other than Water Supply), and any other jurisdictional laws and regulations pertaining to well construction. [15A NCAC 02C .0108] 4. Effluent quality shall not exceed the limitations specified in Attachment A. [15A NCAC 02T .0108(b)(1)] 5. Application rates, whether hydraulic, nutrient or other pollutant, shall not exceed those specified in Attachment B. [15A NCAC 02T .0505(c), 02T .0505(n)] 6. This disposal system was individually permitted on or after December 30, 1983; therefore, the compliance boundary is established at either 250 feet from the effluent disposal area, or 50 feet within the property boundary, whichever is closest to the effluent disposal area. An exceedance of groundwater standards at or beyond the compliance boundary is subject to remediation action according to 15A NCAC 02L .0106(d)(2) as well as enforcement actions in accordance with North Carolina General Statute 143-215.6A through 143-215.6C. [15A NCAC 02L .0106(d)(2), 02L .0107(b)] 7. in accordance with 15A NCAC 02L .0108, the review boundary is established midway between the compliance boundary and the effluent disposal area. Any exceedance of groundwater standards at the review boundary shall require action in accordance with 15A NCAC 02L .0106. [15A NCAC 02L .0106, 02L .0108] 8. The Permittee shall apply for a permit modification to establish a new compliance boundary prior to any sale or transfer of property affecting a compliance boundary. [15A NCAC 02L .0107(c)] 9. In accordance with 15A NCAC 02L .0107(d), no wells, excluding Division approved monitoring wells, shall be constructed within the compliance boundary except as provided for in 15A NCAC 02L ,0107(g). [15A NCAC 02L .0107] 10. Except as provided for in 15A NCAC 02L .0107(g), the Permittee shall ensure any landowner who is not the Permittee and owns land within the compliance boundary shall execute and file with the Randolph County Register of Deeds an easement running with the land containing the following items: a. A notice of the permit and number or other description as allowed in 15A NCAC 02L .0107(f)(1); b. Prohibits construction and operation of water supply wells within the compliance boundary; and c. Reserves the right of the Permittee or the State to enter the property within the compliance boundary for purposes related to the permit. The Director may terminate the easement when its purpose has been fulfilled or is no longer needed. [15A NCAC 02L A 107(f)] WQ0005681 Version 4.0 Shell Version 150213 Page 2 of 8 11. The facilities permitted herein shall be constructed according to the following setbacks: a. The setbacks for irrigation sites permitted under 15A NCAC 02H .0200 shall be as follows (all distances in feet): i. Any habitable residence or place of public assembly under separate ownership: 400 ii. Any drainage ways or surface water bodies: 100 iii. Any well with exception of monitoring wells: 100 iv. Any property line: 150 v. Public right of way: 50 [15A NCAC 02H .02190)] b. The setbacks for storage and treatment units permitted under 15A NCAC 02H .0200 shall be as follows (all distances in feet): i. Any well with exception of monitoring wells: 100 ii. Any property line: 50 [15A NCAC 02H .02190)] I1Q. OPERATION AND MAINTENANCE REQUIREMENTS I . The facilities shall be properly maintained and operated at all times. The facilities shall be effectively maintained and operated as a non -discharge system to prevent the discharge of any wastewater resulting from the operation of this facility. The Permittee shall maintain an Operation and Maintenance Plan, which at a minimum shall include operational functions, maintenance schedules, safety measures and a spill response plan. [15A NCAC 02T .0507] 2. Upon the Water Pollution Control System Operators Certification Commission's (WPCSOCC) classification of the subject non -discharge facilities, in accordance with 15A NCAC 08G .0200 the Permittee shall designate and employ a certified operator in responsible charge (ORC) and one or more certified operator(s) as back-up ORC(s). The ORC or their back-up shall visit the facilities in accordance with 15A NCAC 08G .0200, and shall comply with all other conditions specified in the previously cited rules. [15A NCAC 02T .0117] 3. A suitable year round vegetative cover shall be maintained at all times, such that crop health is optimized, allows for even distribution of effluent and allows inspection of the irrigation system. [15A NCAC 02T .0108(b)(1)] 4. Adequate measures shall be taken to prevent effluent ponding in or runoff from the irrigation sites listed in Attachment B. [ 15A NCAC 02T .0108(b)(1)] 5. Irrigation shall not be performed during inclement weather or when the ground is in a condition that will cause ponding or runoff. [15A NCAC 02T .0108(b)(1)] 6. All irrigation equipment shall be tested and calibrated at least once per permit cycle. Calibration records shall be maintained at the facility for a period of no less than five years, and shall be made available to the Division upon request. [15A NCAC 02T .0108(b)(1)] 7. Only effluent from Pilgrim's Pride Corporation of Georgia's Staley Hatchery & Feed Mill shall be irrigated on the sites listed in Attachment B. [G.S. 143-215.11 8. No automobiles or machinery shall be allowed on the irrigation sites except during equipment installation or while maintenance is being performed. [15A NCAC 02T .0108(b)(1)] WQ0005681 Version 4.0 Shell Version 150213 Page 3 of 8 Public access to the irrigation sites and wastewater treatment facilities shall be prohibited. The spray irrigation field shall be fenced with at least two strand wire fence. [15A NCAC 02T .0505(q)] 10. The residuals generated from the wastewater treatment facilities shall be disposed or utilized in accordance with 15A NCAC 02T A 100. The Permittee shall maintain a residual management plan pursuant to 15A NCAC 02T .0508. [15A NCAC 02T .0508, 02T .1100] 11. Diversion or bypassing of untreated or partially treated wastewater from the treatment facilities is prohibited. [15A NCAC 02T .05050)] 12. Freeboard in the 204,000 gallon treatment and 204,000 gallon storage lagoons shall not be less than one foot at any time. The Permittee shall reduce production and therefore reduce wastewater flow at any time the wastewater levels in either the treatment lagoon or the storage pond are at the required freeboard level. Upon notification by the Division that the increased flow and reduced freeboard requirement is becoming a continuous concern, the Permittee shall reduce wastewater treatment flow back to the previously approved 10,000 GPD immediately. [15A NCAC 02T .0108(b)(1)] 13. Gauges to monitor waste levels in the 204,000 gallon treatment and 204,000 gallon storage lagoons shall be provided. These gauges shall have readily visible permanent markings, at inch or tenth of a foot increments, indicating the following elevations: maximum Iiquid level at the top of the temporary liquid storage volume; minimum liquid level at the bottom of the temporary liquid storage volume; and the lowest paint on tap of the dam. [ 15A NCAC 02T .0108(b)(1)] 14. A protective vegetative cover shall be established and maintained on all earthen embankments (i.e., outside toe of embankment to maximum allowable temporary storage elevation on the inside of the embankment), berms, pipe runs, erosion control areas, and surface water diversions. Trees, shrubs, and other woody vegetation shall not be allowed to grow on the earthen dikes or embankments. Earthen embankment areas shall be kept mowed or otherwise controlled and accessible. [I5A NCAC 02T .0108(b)(1)] 15. For the pump station, the plant operation shall either have a replacement pump of the same size, or a source of replacement nearby (for backup in case of an emergency). The replacement pumping unit shall be maintained in good condition on site at the facility for use in the event that there is a pump failure. In the event of a high water situation, the facility management shall ensure that no bypass or treatment or discharge of untreated wastewater occurs. [15A NCAC 02T .0108(b)(1)] IV. MONITORING AND REPORTING REQUIREMENTS 1. Any Division required monitoring (including groundwater, plant tissue, soil and surface water analyses) necessary to ensure groundwater and surface water protection shall be established, and an acceptable sampling reporting schedule shall be followed. [15A NCAC 02T .0108(c)] 2. A Division certified laboratory shall conduct all laboratory analyses for the required effluent, groundwater or surface water parameters. [15A NCAC 02H .0800] WQ0005681 Version 4.0 Shell Version 150213 Page 4 of 8 3. Flow through the treatment facility shall be continuously monitored, and daily flow values shall be reported on Form NDMR. The Permittee shall install and maintain an appropriate flow measurement device to .ensure the accuracy and reliability of flow measurement consistent with accepted engineering and scientific practices. Selected flow measurement devices shall be capable of measuring flows with a maximum deviation of less than ten percent from true flow; accurately calibrated at a minimum of once per year; and maintained to ensure the accuracy of measurements is consistent with the selected device's accepted capability. The Permittee shall maintain records of flow measurement device calibration on file for a period of at least five years. At a minimum, documentation shall include: a. Date of flow measurement device calibration, b. Name of person performing calibration, and c. Percent from true flow. [ 15A NCAC 02T .0105(k)] 4. The Permittee shall monitor the effluent from the subject facilities at the frequencies and locations for the parameters specified in Attachment A. [ 15A NCAC 02T .0108(c)] The Permittee shall maintain adequate records tracking the amount of effluent irrigated. At a minimum, these records shall include the following information for each irrigation site listed in Attachment B: a. Date of irrigation; b. Volume of effluent irrigated; c. Site irrigated; d. Length of time site is irrigated; e. Continuous weekly, monthly, and year-to-date hydraulic (inches/acre) loadings; f. Continuous monthly and year-to-date loadings for any non -hydraulic parameter specifically limited in Attachment B; g. Weather conditions; and h. Maintenance of cover crops. [I SA NCAC 02T .0108(c)] 6. Freeboard (i.e., waste level to the lowest embankment elevation) in the 204,000 gallon treatment and 204,000 gallon storage lagoons shall be measured to the nearest inch or tenth of a foot, and recorded weekly. Weekly freeboard records shall be maintained at the facility for a period of no less than five years, and shall be made available to the Division upon request. [15A NCAC 02T .0108(c)] Three copies of all monitoring data (as specified in Conditions IV.3. and IVA.) on Form NDMR for each PPI and three copies of all operation and disposal records (as specified in Conditions IV.5. and IV.6.) on Form NDAR-1 for every site in Attachment B shaIl be submitted on or before the last day of the following month. If no activities occurred during the monitoring month, monitoring reports are still required documenting the absence of the activity. All information shall be submitted to the following address: Division of Water Resources Information Processing Unit 1617 Mail Service Center Raleigh, North Carolina 27699-1617 [15A NCAC 02T .0105(i)] WQ0005681 Version 4.0 Shell Version 150213 Page 5 of 8 8. A record shall be maintained of all residuals removed from this facility. This record shall be maintained at the facility for a period of no less than five years, and shall be made available to the Division upon request. At a minimum, this record shall include: a. Name of the residuals hauler; b. Non -Discharge permit number authorizing the residuals disposal, or a letter from a municipality agreeing to accept the residuals; c. Date the residuals were hauled; and d. Volume of residuals removed. [15A NCAC 02T .0108(b)(1)] 9. A maintenance log shall be maintained at this facility. This log shall be maintained at the facility for a period of no less than five years, and shall be made available to the Division upon request. At a minimum, this log shall include: a. Date of calibration of flow measurement device; b. Visual observations of the plant and plant site; and c. Record of preventative maintenance (e.g., changing of equipment, adjustments, testing, inspections and cleanings, etc.). [15A NCAC 02T .0108(b)(1)] 10. Monitoring wells shall be sampled at the frequencies and for the parameters specified in Attachment C. All mapper, well construction forms, well abandonment forms and monitoring data shall refer to the hermit number and the well nomenclature as provided in Attachment C and Figure 2. [15A NCAC 02T A 105(m)] 11. Two copies of the monitoring well sampling and analysis results shall be submitted on a Compliance Monitoring Form (GW-59), along with attached copies of laboratory analyses, on or before the last working day of the month following the sampling month. The Compliance Monitoring Form (GW- 59) shall include this permit number, the appropriate well identification number, and one GW-59a certification form shall be submitted with each set of sampling results. All information shall be submitted to the following address: Division of Water Resources Information Processing Unit 1617 Mail Service Center Raleigh, North Carolina 27699-1617 [15A NCAC 02T .0105(m)] 12. An annual representative soils analysis (i.e., Standard Soil Fertility Analysis) shall be conducted on each irrigation site listed in Attachment B. These results shall be maintained at the facility for a period of no less than five years, and shall be made available to the Division upon request. At a minimum., the Standard Soil Fertility Analysis shall include the following parameters: Acidity Exchangeable Sodium Percentage Phosphorus Base Saturation (by calculation) Magnesium Potassium Calcium Manganese Sodium Cation Exchange Capacity Percent Humic Matter Zinc Copper pH [15A NCAC 02T .0108(c)] WQ0005681 Version 4.0 Shell Version 150213 Page 6 of 8 13. Noncompliance Notification: The Permittee shall report by telephone to the Winston-Salem Regional Office, telephone number (336) 776-9800, as soon as possible, but in no case more than 24 hours, or on the next working day following the occurrence or first knowledge of the occurrence of any of the following: a. Treatment of wastes abnormal in quantity or characteristic, including the known passage of a hazardous substance. b. Any process unit failure (e.g., mechanical, electrical, etc.), due to known or unknown reasons, rendering the facility incapable of adequate wastewater treatment. c. Any facility failure resulting in a by-pass directly to receiving surface waters. d. Any time self -monitoring indicates the facility has gone out of compliance with its permit limitations. e. Ponding in or runoff from the irrigation sites. Any emergency requiring immediate reporting (e.g., discharges to surface waters, imminent failure of a storage structure, etc.) outside normal business hours shall be reported to the Division's Emergency Response personnel at telephone number (800) 662-7956, (800) 858-0368, or (919) 733-3300. Persons reporting such occurrences by telephone shall also file a written report in letter form within five days following first knowledge of the occurrence. This report shall outline the actions taken or proposed to be taken to ensure the problem does not recur. [15A NCAC 02T .0105(1), 02T .0108(b)(1)] V. INSPECTIONS 1. The Permittee shall provide adequate inspection and maintenance to ensure proper operation of the wastewater treatment and irrigation facilities. [15A NCAC 02T .0108(b)] 2. The Permittee or their designee shall inspect the wastewater treatment and irrigation facilities to prevent malfunctions, facility deterioration and operator errors resulting in discharges, which may cause the release of wastes to the environment, a threat to human health or a public nuisance. The Permittee shall maintain an inspection log that includes, at a minimum, the date and time of inspection, observations made, and any maintenance, repairs, or corrective actions taken. The Permittee shall maintain this inspection log for a period of five years from the date of the inspection, and this log shall be made available to the Division upon request. [15A NCAC 02T .0108(b)] 3. Any duly authorized Division representative may, upon presentation of credentials, enter and inspect any property, premises or place on or related to the wastewater treatment and irrigation facilities permitted herein at any reasonable time for the purpose of determining compliance with this permit; may inspect or copy any records required to be maintained under the terms and conditions of this permit, and may collect groundwater, surface water or leachate samples. [G.S. 143-21.5.3(a)(2)] VI. GENERAL CONDITIONS 1. Failure to comply with the conditions and limitations contained herein may subject the Permittee to an enforcement action by the Division in accordance with North Carolina General Statutes 143- 215.6A to 143-215.6C. [G.S. 143-215.6A to 143-215.6C] 2. This permit shall become voidable if the permitted facilities are not constructed in accordance with the conditions of this permit, the Division approved plans and specifications, and other supporting documentation. [15A NCAC 02T .0110] WQ0005681 Version 4.0 Shell Version 150213 Page 7 of 8 3. This permit is effective only with respect to the nature and volume of wastes described in the permit application, Division approved plans and specifications, and other supporting documentation. No variances to applicable rules governing the construction or operation of the permitted facilities are granted, unless specifically requested and approved in this permit pursuant to 15A NCAC 02T .0105(n). [G.S. 143-21.5.11 4. The issuance of this permit does not exempt the Permittee from complying with any and all statutes, rules, regulations, or ordinances, which may be imposed by other jurisdictional government agencies (e.g., local, state, and federal). Of particular concern to the Division are applicable river buffer rules in 15A NCAC 02B .0200; erosion and sedimentation control requirements in 15A NCAC Chapter 4 and under General Permit NCG010000; any requirements pertaining to wetlands under 15A NCAC 02B .0200 and 02H .0500; and documentation of compliance with Article 21 Park 6 of Chapter 143 of the General Statutes. [15A NCAC 02T .0105(c)(6)] In the event the permitted facilities change ownership or the Permittee changes their name, a formal permit modification request shall be submitted to the Division. This request shall be made on official Division forms, and shall include appropriate property ownership documentation and other supporting documentation as necessary. The Permittee of record shall remain fully responsible for maintaining and operating the facilities permitted herein until a permit is issued to the new owner. [15A NCAC 02T ,0104] 6. The Permittee shall retain a set of Division approved plans and specifications for the life of the facilities permitted herein. [ 15A NCAC 02T .0108(b)(1)] 7. The Permittee shall maintain this permit until all permitted facilities herein are properly closed or permitted under another permit issued by the appropriate permitting authority. [15A NCAC 02T .01050)] 8. This permit is subject to revocation or unilateral modification upon 60 days notice from the Division Director, in whole or part for the requirements listed in 15A NCAC 02T .0110. [15A NCAC 02T .0110] 9. Unless the Division Director grants a variance, expansion of the permitted facilities contained herein shall not be granted if the Permittee exemplifies any of the criteria in 15A NCAC 02T .0120(b). [15A NCAC 02T .0120] 10. The Permittee shall pay the annual fee within 30 days after being billed by the Division. Failure to pay the annual fee accordingly shall because for the Division to revoke this permit. [15A NCAC 02T .0105(e)(3)] Permit issued this the 27t' day of August 2015 NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION. S. Jay Zimmerman, P.G., Director Division of Water Resources By Authority of the Environmental Management Commission Permit Number WQ0005681 WQ0005681 Version 4.0 Shell Version 150213 Page 8 of 8 ATTACHMENT A — LIMITATIONS AND MONITORING REQUIREMENTS PPI 001— WWTP Effluent Permit Number: WQ0005681 Version: 4,0 EFFLUENT CHARACTERISTICS EFFLUENT LIMITS MONITORING REQUIREMENTS PCs Code Parameter Description p Units of Measure Monthly Average Monthly Geometric Mean Daily Minimum Daily Maximum Measurement Frequency Sample Type 00310 BOD, 5-Day (20 °C) mg/t. 3 x Year' Grab 00916 Calcium, Total (as Ca) mg/L 3 x Year Grab 50060 Chlorine, Total Residual mg/L 3 x Year Grab 31616 Coliform, Fecal MF, M-FC Broth, 44.5 °C #/100 mL 3 x Year Grab 50050 Flow, in Conduit or thru Treatment Plant GPD 13,000 " ' Continuous Recorder 00927 Magnesium, Total (as Mg) mg/L 3 x Year Grab 00610 Nitrogen, Ammonia Total (as N) mg/L 3 x Year' Grab 00625 Nitrogen, Total Kjeldahl (as N) mg/L 3 x Year 1 Grab 00620 Nitrogen, Nitrate Total (as N) mg/L 3 x Year Grab 00400 pH su 3 x Year Grab 00931 Sodium Adsorption Ratio Ratio 3 x Year' Calculated 00929 Sodium, Total (as Na) mg/L 3 x Year Grab 00530 Solids, Total Suspended mg/L 3 x Year Grab 1. 3 x Year sampling shall be conducted in March, July and November. WQ0005681 Version 4.0 Attachment A Page 1 of 1 THIS PAGE BLANK ATTACHMENT B - APPROVED LAND APPLICATION SITES AND LIMITATIONS Pilgrim's Pride Corporation — Staley Hatchery & Feed Mill Permit Number: WQ0005681 Version: 4.0 IRRIGATION AREA INFORMATION APPLICATION LIMITATIONS Field Owner County Latitude Longitude Net Dominant Parameter Hourly Yearly Units Acreage_. Soil Series Rate Max I Pilgrim's Pride Corporation Randolph 35.8113531 -79.5594820 6.27 GeB2 — Georgeville silty clay loam 01284 —Non-Discharge Application Rate 0.30 35.88 Inches WQ0005681 Version 4.0 Attachment B Page 1 of 1 THIS PAGE BLANK ATTACHMENT C — GROUNDWATER MONITORING AND LIMITATIONS Monitoring wells: MW-1, MW-2 & MW-4 Permit Number: WQ0005681 Version: 4.0 GROUNDWATER CHARACTERISTICS GROUNDWATER STANDARDS MONITORING REQUIREMENTS PCS Code Parameter Description Daily Maximum Frequency Measurement Sample Type Footnotes 00680 Carbon, Tot Organic (TOC) mglL Annually Grab 1, 4, 5 00940 Chloride (as Cl) 250 mglL Annually Grah 1, 5 31616 Coliform, Fecal MF, M-FC Broth, 44.5 °C 41100 mL Annually Grab 1,5 00610 Nitrogen, Ammonia Total (as N) 1.5 mg/L Annually Grab 1,5 00620 Nitrogen, Nitrate Total (as N) 10 mgiL Annually Grab 1,5 00400 pH 6.5-8.5 su Annually Grab 1,5 70300 Solids, Total Dissolved - 180 °C 500 mg/L Annually Grab 1,5 82546 Water Level, Distance from measuring point feet Annually Calculated 1, 2, 3, 5 L Annual monitoring shall be conducted every November. 2. The measurement of water levels shall be made prior to purging the wells. The depth to water in each well shall be measured from the surveyed point on the top of the casing. The measurement of pH shall be made after purging and prior to sampling for the remaining parameters. 3. The measuring points (top of well casing) of all monitoring wells shall be surveyed to provide the relative elevation of the measuring point for each monitoring well. The measuring points (top of casing) of all monitoring wells shall be surveyed relative to a common datum. 4. If TOC concentrations greater than 10 mglL are detected in any downgradient monitoring well, additional sampling and analysis must be conducted to identify the individual constituents comprising this TOC concentration. If the TOC concentration as measured in the background monitor well exceeds 10 mglL, this concentration will be taken to represent the naturally occurring TOC concentration. Any exceedances of this naturally occurring TOC concentration in the downgradient wells shall be subject to the additional sampling and analysis as described above. 5. Monitoring wells shall be reported consistent with the nomenclature and location information provided in Figure 2 and this attachment. WQ0005681 Version 4.0 Attachment C Page 1 of l m - - 1 ly 24E �� ��' . �� j•. '�_ r3: t � tij �. � -j�' `- �.-<. � _ fit _ N35 48.633 a �.�ji% �•'- - 9... ' f _`, „- if E •f �.. fl �' a '--'" _ �I r. 1 1 � _ .�♦s �! sti�--�`` —�-� �! � I —,i it pel it. tc�ilv�`rs em s_. ' 693 - FIGURE 1 JJ PILGRIMS PRIDE CORPORATION WASTEWATER IRRIGATION SYSTEM �. ' RANDOLPH COUNTY VICINITY MAP r:� vrs+s� n..l nrr... a-n ra�nc3. a.+a c,a n:,r., �o nvrie hx of �nrre-,:F .„•.,,�,. � — _ _ _ _ _ f ' :TiJ lGC _ i ,. Ai 7 i > E h _1 f. -77 •v ned 14eo*q.,t�,,,i. W01% (�lt3Sjt01d17{C {�(yilfli l'3r6�i�^- � � P• -z�:'- . rn . aama Farm Road Yvivv ilrrt4 E-iEre'rr Tx f^: . Railroad s':[raQY - . r .. ��.,, Sul fit" Walvr - Boundan stud Oje Ix'rimell'r o thr io-,.Wctttd Area FIGURE z All locr€ioaraarcalal:n�ittfrttc;�rnelt�c�t;wrevdt<t_ �.le� 1" 3ftt,ti'; PILGRIMS PRIDE CORPORATION Data providt�d h}'. t 3 6rd 1;U B < <� „ WASTEWATER IRRIGATION SYSTEM ii `<,sti4_fna) °!e?ii�ti[friru! Itat.r ery {aa<➢s;ram BRANCH `s .Pit II RANDOLPH COUNTY ,vid Randolph Cot aiv (1Iti RESIDUALS WQ000568 Ntr� 4'10 & SOILS, LaLC F'��.,f'.� of� �: SITE DETAIL MAP