HomeMy WebLinkAboutWQ0005615_Final Permit_20020614June 14, 2002
REBECCA S. GAUL
11 COYOTE LANE
CARSON, CA 90745
Dear Ms. Gaul:
Michael F. Easley, Governor
William G. Ross Jr., Secretary
North Carolina Department of Environment and Natural Resources
Alan W. Klimek, P.E., Director
Division of Water Quality
Subject: Permit No. WQ0005615
Single Family Residence
Spray Irrigation Facility
Chatham County
In accordance with your renewal request received August 15, 2001 and additional information received
on February 1, 2002, , we are forwarding herewith Permit No. WQ0005615, dated June 14, 2002, to Rebecca S.
Gaul for the continued operation of the subject single family wastewater treatment and spray irrigation facilities.
This permit shall be effective to the date of issuance until April 30, 2007, shall void Permit No.
WQ0005615 issued February 5, 1997, and shall be subject to the conditions and limitations as specified therein.
Please pay particular attention to the monitoring requirements in this permit. Failure to establish an adequate
system for collecting and maintaining the required operational information will result in future compliance
problems.
If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to
request an adjudicatory hearing upon written request within thirty (30) days following receipt of this permit. This
request must be in the form of a written petition, conforming to Chapter 150B of the North Carolina General
Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, NC 27699-
6714. Unless such demands are made this permit shall be final and binding.
If you need additional information concerning this matter, please contact Nathaniel Thornburg at (919)
733-5083 extension 533.
Sin
c y,
,/,Alan W. Klimek, P.E.
cc: Chatham County Health Department
Raleigh Regional Office, Water Quality Section
Technical Assistance and Certification Unit
Non -Discharge Compliance/Enforcement Unit
Water Quality Central Files
NDPU Files
WWI
Non -Discharge Permitting Unit Internet http-.//h2o.enr.state.nc.us/ndpu PiMENR
16I7 Mail Service Center, Raleigh, NC 27699-1617 Telephone (919) 733-5083 Fax (919) 715-6048
DENR Customer Service Center Telephone 1 800 623-7748
An Equal Opportunity Action Employer 50% recycled/10%o post -consumer paper
NORTH CAROLINA
ENVIRONMENTAL MANAGEMENT COMMISSION
DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES
RALEIGH
SINGLE FAMILY SPRAY IRRIGATION PERMIT
In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended,
and other applicable Laws, Rules, and Regulations
PERMISSION ISHEREBY GRANTED TO
Rebecca S. Gaul
Chatham County
FOR THE
continued operation of a 360 gallon per day (GPD) spray irrigation wastewater treatment and disposal system
consisting of a 1,000 gallon baffled septic tank, a 396 square foot (ft) subsurface sand filter, a tablet chlorinator
disinfection unit, a 2,000 gallon storage/irrigation pump tank, and a 13,602 square foot spray irrigation area to
serve the Rebecca S. Gaul Residence, with no discharge of wastes to the surface waters, pursuant to the
application received August 15, 2001 and additional information received on February 1, 2002, and in conformity
with the project plan, specifications, and other supporting data subsequently filed and approved by the
Department of Environment and Natural Resources and considered a part of this permit.
This permit shall be effective from the date of issuance until April 30, 2007, shall void Permit No.
WQ0005615 issued February 5, 1997, and shall be subject to the following specified conditions and limitations:
I. PERFORMANCE STANDARDS
I. The spray irrigation facilities shall be effectively maintained and operated at all times so that there is no
discharge to the surface waters, nor any contamination of ground waters which will render them
unsatisfactory for normal use. In the event that the facilities fail to perform satisfactorily, including the
creation of nuisance conditions or failure of the irrigation area to adequately assimilate the wastewater,
the Permittee shall take immediate corrective actions including those actions that may be required by
the Division of Water Quality (Division), such as the construction of additional or replacement
wastewater treatment and disposal facilities.
2. The issuance of this permit shall not relieve the Permittee of the responsibility for damages to surface or
groundwaters resulting from the operation of this facility.
3. The sand media of the subsurface surface sand filter must comply with the Division's sand
specifications.
4. The residuals generated from these treatment facilities must be disposed in accordance with General
Statute 143-215.1 and in a manner approved by the Division.
5. Diversion or bypassing of the untreated wastewater from the treatment facilities is prohibited.
6. The following buffers shall be maintained:
a) 400 feet between wetted area and any residence or places of public assembly under separate
ownership,
b) 150 feet between wetted area and property lines,
c) 100 feet between wetted area and wells,
d) 100 feet between wetted area and drainage ways or surface water bodies,
e) 50 feet between wetted area and public right of ways,
f) 100 feet between treatment/storage units and any wells, and
g) 50 feet between treatment units and property lines.
Some of the buffers specified above may not have been included in previous permits for this waste
treatment and disposal system. These buffers are not intended to prohibit or prevent modifications,
which are required by the Division, to improve performance of the existing treatment facility. These
buffers do, however, apply to modifications of the treatment and disposal facilities which are for the
purpose of increasing the flow that is tributary to the facility. These buffers do apply to any
expansion or modification of the spray irrigation areas and apply in instances in which the sale of
property would cause any of the buffers now complied with, for the treatment and disposal facilities,
to be violated. The applicant is advised that any modifications to the existing facilities will require a
permit modification.
II. OPERATION AND MAINTENANCE REOUIREMENTS
I. The facilities shall be properly maintained and operated at all times.
2. Upon classification of the facility by the Water Pollution Control System Operators Certification
Commission (WPCSOCC), the Permittee shall employ a certified wastewater treatment plant operator
to be in responsible charge (ORC) of the wastewater treatment facilities. The operator trust hold a
certificate of the type and grade at least equivalent to or greater than the classification assigned to the
wastewater treatment facilities by the WPCSOCC. The Permittee must also employ a certified back-up
operator of the appropriate type and grade to comply with the conditions of 15A NCAC 8G .0202. The
ORC of the facility must visit each Class I facility at least weekly and each Class II, III, and IV facility
at Ieast daily, excluding weekends and holidays, and must properly manage and document daily
operation and maintenance of the facility and must comply with all other conditions of 15A NCAC 8G
.0202. Once the facility is classified, the Permittee must submit a letter to the WPCSOCC which
designates the operator in responsible charge within thirty days after the wastewater treatment facilities
are 50% complete.
3. A suitable year round vegetative cover shall be maintained.
4. Irrigation shall not be performed during inclement weather or when the ground is in a condition that
will cause runoff.
5. Adequate measures shall be taken to prevent wastewater runoff from the spray field.
6. The application rate shall not exceed a cumulative loading of 16.64 inches over any twelve (12) month
period at an instantaneous application rate not to exceed 0.051 inches per hour.
7. The facilities shall be effectively maintained and operated as a non -discharge system to prevent the
discharge of any wastewater resulting from the operation of this facility.
8. No type of wastewater other than that from the Rebecca S. Gaul Residence shall be sprayed onto the
irrigation area.
9. No traffic or equipment shall be allowed on the disposal area except while installation occurs or while
normal maintenance is being performed.
2
10. The spray irrigation field shall be fenced with at least a two -strand wire fence.
11. The Permittee is responsible for the operation and maintenance of the entire treatment and disposal
system including, but not limited to, the following items:
a. The septic tank shall be checked annually and pumped out as needed.
b. The tablet chlorinator unit shall be checked every week. Tablets shall be added so as to provide
proper chlorination.
c. The storage, pump, and alarm systems shall be inspected monthly. The scum layer shall be
removed at the same interval as the septic tank is cleaned out.
d. The spray system shall be inspected monthly to make certain of the sprayers proper operation,
that the vegetative growth allows a proper spray pattern, that the soil is assimilating the disposed
treated wastewater with no surface runoff, and that no objectionable odors are being generated.
III. MONITORING AND REPORTING REQUIREMENTS
1. Any monitoring deemed necessary by the Division to insure surface and ground water protection will
be established and an acceptable sampling reporting schedule shall be followed.
2. The Permittee shall maintain records of all maintenance performed on the system and irrigation area, as
required in Condition 11(1 1) for a minimum of five years. This information shall be provided to the
Division upon request.
3. Noncompliance Notification:
The Permittee shall report by telephone to the Raleigh Regional Office, telephone number (919) 571-
4700, as soon as possible, but in no case more than 24 hours or on the next working day following the
occurrence or first knowledge of the occurrence of any of the following:
a. Any process unit failure, due to known or unknown reasons, that renders the facility incapable of
adequate wastewater treatment, such as mechanical or electrical failures of pumps, emitters, etc.;
or
b. Any failure of a pumping station or treatment facility resulting in a by-pass directly to receiving
waters without treatment of all or any portion of the influent to such station or facility.
Persons reporting such occurrences by telephone shall also file a written report in letter form within
five (5) days following first knowledge of the occurrence. This report must outline the actions taken
or proposed to be taken to ensure that the problem does not recur.
IV. INSPECTIONS
1. Adequate inspection, maintenance, and cleaning shall be provided by the Permittee to insure proper
operation of the subject facilities.
2. Any duly authorized officer, employee, or representative of the Division may, upon presentation of
credentials, enter and inspect any property, premises or place on or related to the disposal site or facility
at any reasonable time for the purpose of determining compliance with this permit, may inspect or copy
any records that must he maintained under the terms and conditions of this permit, and may obtain
samples of groundwater, surface water, or leachate.
V. GENERAL CONDITIONS
This permit shall become revocable unless the facilities are constructed in accordance with the
conditions of this permit, the approved plans and specifications, and other supporting data.
This permit is effective only with respect to the nature and volume of wastes described in the
application and other supporting data.
This permit is not transferable. In the event there is a desire for the facilities to change ownership, or
there is a name change of the Permittee, a formal permit request must be submitted to the Division
accompanied by documentation from the parties involved, and other supporting materials as may be
appropriate. The approval of this request will be considered on its merits and may or may not be
approved.
4. Upon the availability of a municipal or regional sewerage collection system, the subject wastewater
treatment facilities shall be abandoned and all wastewater discharged into the municipal or regional
sewerage system.
Failure to abide by the conditions and limitations contained in this permit may subject the Permittee
to an enforcement action by the Division in accordance with North Carolina General Statute 143-
215.6A to 143-215.6C.
6. The issuance of this permit does not exempt the Permittee from complying with any and all statutes,
rules, regulations, or ordinances which may be imposed by other government agencies (local, state,
and federal) which have jurisdiction, including but not limited to applicable river buffer rules in 15A
NCAC 2B.0200, erosion and sedimentation control requirements in 15A NCAC Chapter 4 and under
the Division's General Permit NCG010000, and any requirements pertaining to wetlands under 15A
NCAC 2B .0200 and 2H .0500.
7. This permit may be revoked if the Permittee fails to abide by the conditions of the "Operation and
Maintenance Agreement" previously signed by the Permittee.
One set of approved plans and specifications Tor the subject project must be retained by the Permittee
for the life of the project.
9. The annual administering and compliance fee must be paid by the Permittee within 30 days after
being billed by the Division. Failure to pay the fee accordingly may cause the Division to initiate
action to revoke this permit as specified by ISA NCAC 2H .0205 (c)(4).
10. The Permittee, at least six (6) months prior to the expiration of this permit, shall request its extension.
Upon receipt of the request, the Commission will review the adequacy of the facilities described
therein, and if warranted, will extend the Permit for such period of time and under such conditions
and limitations as it may deem appropriate.
of June, 2002
)NMENTAL MANAGEMENT COMMISSION
Alan W. Klimek, P.E., Director
Division of Water Quality
By Authority of the Environmental Management Commission
Permit Number WQ0005615
4
z
450
00)
-
�W
j
/� ` goo s9z �6i
�43i
`
W
35�
�j ..
165 11930 000 FEET 661 662E 12`0" 653
vd, and published by the Geological Survey SC
5, NOSINOAA, and OSCE
MN 1000 0 1000 2400 -
lotogrammetric methods from aerial photographs cN
d checked 1970 .5
ion. 10,000 -foot grid ticks based on North Carolina 6-
o. 1000 -meter Universal Transverse Mercator 107 nnrts 1'os' CONTOUR
OPERATION AND MAINTENANCE AGREEMENT
SINGLE FAMILY RESIDENCE WASTEWATER TREATMENT SYSTEM
DIVISION OF -WATER QUALITY
Owner: Rebecca S. GaulT
Address: 11 Coyote _Lane Carsnn,-CA 90745.___.._
Disposal Method: RAYIRRIGATION DRIP IRRIGATION (Circle One)
County: CHATHAM
1 ,111 1 .:
I agree to operate and maintain the wastewater treatment system as follows:
1) The Permittee is responsible for the operation and maintenance of the entire treatment and disposal
system including, but not limited to, the following items:
a) The septic tank shall be checked annually and pumped out as needed. The effluent filter shall be
checked and cleaned at the same frequency of the septic tank.
b) Check one:
The tablet chlorinator shall be checked every week. Tablets shall be added so as to provide
proper chlorination.
❑ The ultraviolet disinfection unit shall be checked every week. The lamp shall be cleaned
and/or replaced to ensure proper disinfection.
c) The storage, pump, and alarm systems shall be inspected monthly. The scum layer shall be
removed at the same time interval as the septic tank is pumped out.
d) The irrigation system shall be inspected monthly to make certain of proper operation, that
vegetative growth does not interfere with the system inspection or operation, that the soil is
assimilating the disposed treated wastewater with no surface runoff, and that no objectionable
odors are being generated.
2) Failure of the Permittee to properly operate this system is subject to a penalty up to $25,000 per day.
3) Failure to meet the permit conditions or violation of the State's surface or groundwater regulations
will require evacuating the dwelling and may void the permit.
I understand the above requirements and agree to these terms as part of the issued permit.
Owner Signature:
Notary Signature:
Date: - �la
SFR O&M 04/01
LV111111AJJ1 Vll L.11ffil ULl VlI.
Date: / /6 —(J r2--
iotary Seal:
ffff" r %
`.0N, 1Y •• °oa
f','
0�+
•
O
!!!ttl11 fttitili
WATER POLLUTION CONTROL SYSTEM OPERATORS
CERTIFICATION COMMISSION
CLASSIFICATION
RATING SHEET FOR WATER POLLUTION CONTROL SYSTEMS
FACILITY INFORMATION:
NAME OF FACILITY:
MAILING ADDRESS:
e
C� q s--
COUNTY: a
CONTACT PERSON: R� e GGQ 6a o f TELEPHONE: (3 I S 3 S 11W—
PERMIT
1W OPERMIT NO: Wn 000 5-6 f 5- Check One: NC WQ ✓ HEALTH DP—
Is) a 01
P
Cs) 301
TELEPHONE:
RATING INFORMATION: (Before completing this section, please refer to pages 2-4)
PFY,M[TTEDs i/ 00 i
C �I �;�� �.Y►�I ��7:rll�C��`� i �lM11yXI'L114110I'm
SPRAY IRRIGATION SUBSURFACE
PHYSICAIJCHEMICAL GRADE I
BNR? YES NO .
2 3 4
2 3 4
LAND APPLICATION
GRADER
RATED BY: �6 I LAOM REGION:
R DATE:
REGIONAL OFFICE TELEPHONE NUMBER: (i
l f ) 5-7I —q700
EXT:
Classification of Biological Water Pollution Control Treatment Systems:
Grade I Biological WPCS
- Septic tanVsand filter systems
- Biological lagoon systems
- Constructed wetlands and associated appurtenances
Grade II Biological WPCS
- Systems that utilize an activated sludge or fixed growth process with a permitted flow
less than or equal to 0.5 million gallons per day (mgd)
Grade III Biological WPCS
- Systems that utilize an activated sludge or fixed growth process with a permitted flow
of greater than 0.5 through 2.5 million gallons per day (mgd)
- Grade II systems that are required to achieve biological nutrient reduction *
Grade IV Biological WPCS
- Systems that utilizing an activated sludge or fixed growth process with a permitted flow
of greater than 2.5 million gallons per day (mgd)
- Grade III systems that are required to achieve biological nutrient reduction *
* Biological Nutrient Reduction -
The reduction of total nitrogen or total phosphorous by an activated sludge or faxed growth
process as required by the facilities permit.
Classification of Collection Water Pollution Control Systems:
(whichever provides lowest grade)
Same grade as biological water pollution control system. Grade of system:
Based on population served:
1,500. or Less = Grade I
1,501 to 15,000 = Grade II
15,001 to 50,000 = Grade III
50,001 or more = Grade IV
Classification of Spray frrization Water Pollution Control Systems:
V Systems which utilize spray irrigation for the reuse or disposal of wasterwater.
These systems include septicUnks, sand filter, oil/water separators, lagoons,
storage basins, screening, sedimentation. Systems other than those listed above
shall be subject to additional classification.
Classification of Land Application of Residuals Systems:
Systems permitted and dedicated for land application of residuals that are produced by a
water pollution control system or contaminated soils.
Classification of Physical/Chemical-Water Pollution Control Treatment Systems:
Grade I Physical/Chemical: Any water pollution control system that utilizes a primarily
physical process to treat wastewater. This classification includes groundwater
remediation systems. **
Grade H Physical/Chemical: Any water pollution control system that utilizes a primarily
chemical process to treat wastewater. This classification includes reverse osmosis,
electrodialysis, and ultrafiltration systems. **
** Any water pollution control system that utilizes a phyical/chemical process to enhance an
activated sludge or fixed growth process, shall not be subject to additional classification.
Classification of Subsurface Water Pollution Control Systems:
Systems which utilize the soil for subsurface treatment and disposal of wastewater
and/or are required to have a certified operator under 15A NCAC 18A.1961. ***
*** Any subsurface system that has as pan of its treatment process a water pollution control
systems that may be classified under Rules .0302 through.0307 of this section shall be
subject to addional classification.
Definitions
Activated Sludge - shall mean a biological wastewater treatment process in which predominantly
biodegradable poiluntants in wastewater are absorbed, or adsorbed by living aerobic organisms and
bacteria.
Chemical Process - shall mean a wastewater pollution control system process consisting
exclusively of the addition of chemicals to treat wastewater.
Collection System - shall mean a continuous connections of pipelines, conduits, pumping
stations, and other related constructions used to conduct wastewater to the water pollution
control system.
Electrodialysis System - shall mean a system utlizing a selective separation of dissolved solids
process that is based on electrical charge and diffusion through a semipermeable membrane.
Physical Process - shall mean any water pollution control system process consisting of
electrodialysis, adsorption, absorption, air stripping, gravimetric sedimentation, floation, and
filtration as a means of treatment.
Reverse Osmosis System - shall mean a system which utilizes solutions and semipermable
membranes to separate and treat wastewater.
Ultrafiltration System - shall mean a system which utilizes a membrane filter to remove
pollutants from wastewater.
Water Pollution Control System - shall mean any system for the collection., treatment, or
disposal of wastewater and is classified under the provision of G.S. 90A -37 -
Note: .Please refer to G.S- 90A-37 for additional information and definitions.