HomeMy WebLinkAboutWQ0004797_Correction_20080731Michael F. Easley, Governor William G. Ross Jr., Secretary North Carolina Department of Environment and Natural Resources Coleen H. Sullins, Director Division of Water Quality July 31, 2008 Blake Kehoe — Plant Manager Clement Pappas NC, .Inc. P.O. Box. 1009 Mountain Hone, NC 28758 Subject: Acknowledgement of Engineering Certification and Permit Correction Permit Number WQ0004797 Clement Pappas NC, Inc Wastewater Surface Irrigation Henderson County Dear Mr. Kehoe: The Division's Land Application Unit has received your signed and sealed certification for the subject facility. The Division hereby accepts this certification based upon its execution and submittal by a North Carolina Professional Engineer. In accordance with the engineer's final certification received on July 31, 2008, We are forwarding herewith the corrected Page 1 of Permit No. WQ0004797, issued December 29, 2006, for the subject facility. Page 1 has been modified to reflect the actual irrigation areas presented in the engineer's final certification Sincer�, ,)eColeen H. Sullins cc: Asheville Regional Office, Aquifer Protection Section Christopher Gilbert, P.E. Altamont Environmental, Inc. 50 College Street, Asheville NC 28801 LAU File WQ0004797 ilrQe Carolina oNtuxlallff Aquifer Protection Section 1636 Mail Service Center Raleigh, NC 27699-1636 'telephone: (919) 733-3221 Internet: www.ncwaterctuali .org Location: 2728 Capital Boulevard Raleigh, NC 27604 Fax L- (919) 715-0588 Fax 2: (9€9)715-6048 An Equal Opportunity/Affirmative Action Employer— 50°/a Recycled/ 10% Post Consumer Paper Customer Service: (877) 623-6748 NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES RALEIGH SURFACE IRRIGATION SYSTEM PERMIT In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations PERMISSION IS HEREBY GRANTED TO Clement Pappas STC, Inc, Henderson County FOR THE continued operation of an average 83,000 -GPD spray irrigation treatment and disposal facility consisting of a separation basin, a 100 -GPM pump station, approximately 2,200 linear feet of 6 -inch force main, a 2.5 -MG aerated lagoon, a 475 -GPM spray irrigation pump and a 50.49 -acre spray irrigation field and all associated piping, valves, controls, spray heads and appurtenances construction of one 40 hp 475 -GPM spray irrigation pump and approximately 600 feet of 8 -inch force main and all associated piping, valves, controls, and appurtenances upon successful completion of the preliminary pumping pilot test, construction of one 40 hp 475 -GPM transfer pump, approximately 650 linear feet of 4 -inch force main, a 1.75 MG above ground wastewater storage tank, a Rosemount magnetic flowmeter or equivalent, and all associated piping, valves, controls, and appurtenances to increase the facility's capacity to 137,000 GPD. to serve the Clement Pappas Mountain Home Facility, with no discharge of wastes to the surface waters, pursuant to the application received August 28, 2006, and in conformity with the project plan, specifications, and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources and considered a part of this permit. This permit shall be effective from the date of issuance until November 30, 2011, shall void Permit No. WQ0004797 issued July 3, 2002, and shall be subject to the following specified conditions and limitations: I. PERFORMANCE STANDARDS 1. Upon completion of construction and prior to operation of this permitted facility, a certification must be received from a professional engineer certifying that the permitted facility has been installed in accordance with this permit, the approved plans and specifications, and other supporting materials. If this project is to be completed in phases and partially certifiedyou shall retain the responsibilfty to track further construction approved under the samepen-nit,.and shall provide a final certificate of completion once the entire prof pct has been completed. Mail the Certification to the Land Application Unit, Division of Water Quality, 1636 Mail Service Center, Raleigh, NC 27699-1636. NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES RALEIGH SURFACE IRRIGATION SYSTEM PERMIT In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations PERMISSION IS HEREBY GRANTED TO Clement Pappas NC, Inc. Henderson County FOR THE continued operation of an average 83,000 -GPD spray irrigation treatment and disposal facility consisting of a separation basin, a 100 -GPM pump station, approximately 2,200 linear feet of 6 -inch force main, a 2.5 -MG aerated lagoon, a 475 -GPM spray irrigation pump and a 50.49 -acre spray irrigation field and all associated piping, valves, controls, spray heads and appurtenances construction of one 40 hp 475 -GPM spray irrigation pump and approximately 600 feet of 8 -inch force main and all associated piping, valves, controls, and appurtenances upon successful completion of the preliminary pumping pilot test, construction of one 40 hp 475 -GPM transfer pump, approximately 650 linear feet of 4 -inch force main, a 1.75 MG above ground wastewater storage tank, a Rosemount magnetic flowmeter or equivalent, and all associated piping, valves, controls, and appurtenances to increase the facility's capacity to 137,000 GPD. to serve the Clement Pappas Mountain Home Facility, with no discharge of wastes to the surface waters, pursuant to the application received August 28, 2006, and in conformity with the project plan, specifications, and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources and considered a part of this permit. This permit shall be effective from the date of issuance until November 30, 2011, shall void Permit No. WQ0004797 issued July 3, 2002, and shall be subject to the following specified conditions and limitations: PERFORMANCE STANDARDS Upon completion of construction and prior to operation of this permitted facility, a certification must be received from a professional engineer certifying that the permitted facility has been installed in accordance with this permit, the approved plans and specifications, and other supporting materials. If this project is to be completed in phases and Dar-tially certified you shall retain the responsibility to track further construction approved under the same permit an_ d shall provide a _final certificate of completion once the entire roject has been complete . Mail the Certification to the Land Application Unit, Division of Water Quality, 1636 Mail Service Center, Raleigh, NC 27699-1636.