Loading...
HomeMy WebLinkAboutWQ0000864_Final Permit_19901016may. State of North Carolina Department of Environment, Health and Natural Resources Division of Environmental Management 512 North Salisbury Street • Raleigh, North Carolina 27611 James G. Martin, Governor William W. Cobey, Jr., Secretary October 16, 1990 Mr, Lee Isenhour, Director of Safety and Security comm/Scope, Incorporated jtoute 1 Box 199 (.4tawba, North Carolina 28609 poar Mr. Isenhour: George T. Everett, Ph.D. Director Subject: Permit No. WQOOW864 Additional Information Cable Transport Catawba Facility Subsurface Disposal Facility Catawba County The Permits and Engineering Unit received the renewal request for the subject permit on August 27, 1990. On October 3, 1990 the Mooresville Regional Office notified the Permits and gpgineering Unit that the facility was washing more vehicles than the wastewater treatment facility WAS originally designed and permitted for. Therefore, additional information is needed to deter -line If the facility is adequately designed for the increased volume of wastewater. Please provide the following additional information: 1) Provide a completed Non -Discharge application for the increased wastewater volume, , 2) Provide an estimate of the volume of wastewater now being generated at this facility. Provide the method used to determine the volume of wastewater such as water use records or flow meter readings at the facility. 3) Provide a site-specific map, with topographic contours (contour interval should not exceed 10 feet or 25% of the total site relief, whichever is less), showing all facility -related structures within the property boundary and the location of all wells, springs, lakes, ponds, or other drainage features within 500 feet of the waste treatment/disposal site(s). Wells should be labeled as to their primary usage (drinking water, irrigation, monitoring, etc.). 4) Provide a soil scien ti st/hydro geological report of the disposal site. This report should include a description of the soils to a depth of 20 feet or bedrock, which ever is less. The description should include field descriptions of each soil horizon, texture, structure, seasonal high water table and normal water table depths, and a loading rate. The hydrogeological information should include information on the vertical permeability of the soils and any changes in soil horizons, and an estimate of thee hydraulic conductivity of the saturated zone. Pollution Prevation Pays P.O. Box 276$7, Raleigh, Noah Carolina 27611-7697 Telephone 919-733-7015 An Equal Opportunity Affirmative Action Employer Mr. Isenhour October 16, 1990 Page Two The Mooresville Regional Office reported that Comm/Scope was in the process of constructing a wash water recycle system to replace the subsurface disposal system. Has this recycle system been permited by the Division? Will the subsurface system still be needed once the recycle system has come online? Refer to the subject permit application number when providing the requested information. Also, please now that failure to provide this additional information on or before December 15, 1990 will.subject your application to being returned as incomplete in accordance with 15 NCAC 2H .0208. If you have any questions on this matter, please call me at 9391733-5083. Sincerely, Mark E. Hawes Environmental Engineer cc: Mooresville Regional Office Groundwater Section