HomeMy WebLinkAboutWQ0000760_Correction_20030416`o�aF INA
co
■ 1 ►14
Michael F. Easley, Governor
William G. Ross Jr., Secretary
North Carolina Department of Environment and Natural Resources
April 16, 2003
MR. DAVID W. WEBER, STAFF ENGINEER -ENV IRONMENTAL
PPG INDUSTRIES FIBER GLASS PRODUCTS, INC.
473 NEw JERSEY CHURCH ROAD
LEXINGTON, NORTH CAROLINA 27292
Dear Mr. Weber:
Alan W- Kiimek, P.E., Director
Division of Water Quality
Subject: Permit No. WQ0000760 Correction
PPG Industries Fiber Glass Products, Inc.
Lexington, NC Fiber Glass Products Plant
Residuals Land Application Program
Land Application of Residual Solids (503 Exempt)
Davidson County
In accordance with a facsimile request from Ms. Rhonda Money of Synagro South, Inc. received
by Mr. Daryl Merritt of the Division of Water Quality's (Division) Non -Discharge
Compliance/Enforcement Unit on April 17, 2003, we are forwarding herewith a corrected Page 9 of
Permit No. WQ0000760, issued on October 25, 2002, for the subject residuals land application program.
The following correction has been made to the permit:
I. Condition Ill. 6. lists items regarding residuals land application activities that the Permittee
must track and report to the Division on an annual basis. Paragraph k. of this condition
requires that the Permittee record totals of residuals, nutrients, and metals that are applied to
each land application site on an annual and cumulative basis. The language has been
corrected to reflect the fact that the Permittee only has to track the application of metals for
which the residuals are required to be analyzed (i.e., cadmium, copper. lead, nickel, and
zinc). Note that tracking of arsenic, mercury, molybdenum and selenium loading on each
land application site is not required, since the residuals are not required to be analyzed for
these metal parameters.
The Division apologizes for any confusion that this error might have caused, and we
appreciate your and Ms. Money's diligence in reviewing this permit thoroughly and calling
these issues to our attention. The discovery of this error is very important to the Division, as
it has prompted us to correct the template from which all permits for non -dedicated residuals
land application program that are not regulated under 40 CFR Part 503 are developed.
Please replace Page 9 with this corrected Page 9 into Permit No. WQ0000760, issued on
October 25, 2002.
Non -Discharge Permitting Unit
1517 Mail Service Center, Raleigh, NC 27699-1617
DEN Customer Service Center
An Equal Opportunity Action Employer
NCDFNR
Internet httpJ/h2o.enr.state-nc.Wndpu
Telephone (919) 733-5083 Fax (919) 715-6048
Telephone 1 800 623-7748
50% recycled/10% post -consumer paper
If you need any additional information concerning this matter, please contact Ms. Shannon Mohr
Thornburg via telephone at (919) 733-5083, extension 353, or through e-mail at
shannon.thornburg@ncmail.net.
Sinc e,Iy,
for Alan W. Klimek, P.E.
Enclosure
cc: Mr. Martin E. Mabe, Synagro South, Inc.
Davidson County Health Department
Winston-Salem Regional Office -Water Quality Section
Winston-Salem Regional Office -Groundwater Section
Central Office -Groundwater Section
Water Quality Central Files
NDPU Files
NDPQ,Residtials Ppogram t66'-rdinatar
. yv'
2
k. Annual and cumulative totals of dry tons per acre of residuals as well as animal waste and
other source of nutrients residuals (i.e., if applicable), annual and cumulative pounds per
acre of each heavy metal (i.e., shall include, but shall not be limited to, cadmium, copper,
lead, nickel, and zinc), annual pounds per acre of PAN, and annual pounds per acre of
phosphorus applied to each field.
7. A representative annual soils analysis (i.e., Standard Soil Fertility Analysis) shall be
conducted on each land application site on which a residuals land application event in the
respective calendar year has occurred, and the results shall be maintained on file by the
Permittee for a minimum of five years. The Standard Soil Fertility Analysis shall include,
but is not necessarily Iimited to, the following parameters:
Acidity Exchangeable Sodium Percentage (by calculation)
Calcium Magnesium Phosphorus
Cation Exchange Capacity Manganese Potassium
Copper Percent Hun& Matter Sodium
Base Saturation (by calculation) pH Zinc
8. Three copies of all required monitoring and reporting requirements as specified in Condition
Ili. 1., Condition 1111.2_, Condition III. 3., Condition 111.4., Condition IH, 5., Condition III. 6..
and Condition III. 7. shall be submitted annually on or before March ist of the year following
the residuals land application event to the following address:
NCDENR-DWQ
Water Quality Section
Non -Discharge Compliance/Enforcement Unit
1617 Mail Service Center
Raleigh, North Carolina 27699-1617
9. Noncompliance Notification:
The Permittee shall report by telephone to the VVater Quality Section of the Division's
Winston-Salem Regional Office at telephone number (336) 771-4600, as soon as possible,
but in no case more than 24 hours or on the next working day following the occurrence or
first knowledge of the occurrence of any of the following:
a. Any occurrence with the residuals land application program that results in the land
application of significant amounts of residuals that are abnormal in quantity or
characteristic.
b. Any failure of the residuals land application program resulting in a release of material to
receiving waters.
c. Any time that self-monitoring information indicates that the residuals land application
program has gone out of compliance with the conditions and Iimitations of this permit or
the parameters on which the program system was designed.
d_ Any process unit failure, due to known or unknown reasons, that render the residuals land
application program incapable of adequate residuals treatment.
e. Any spillage or discharge from a vehicle or piping system transporting residuals to the
application site.
Persons reporting such occurrences by telephone shall also fie a written report in letter form
within five days following first knowledge of the occurrence. This report shall outline the
actions taken or proposed to be taken to ensure that the problem does not recur.
0