Loading...
HomeMy WebLinkAboutWQ0000731_Final Permit_20120215NCDENR North Carolina Department of Environment and Natural Resources Division of Water Quality Beverly Eaves Perdue Gha6es Wakild, P. E. Governor Director February 15, 2012 Mr. Reginald D. Heinitsh, Chairman Lake Toxaway Company 4366 West Club Boulevard Lake Toxaway, North Carolina 28747-8538 Dear Mr. Heinitsh: Dee Freeman Secretary Subject: Permit No_ WQ0000731 Lake Toxaway Country Club Non -Conjunctive Reclaimed Water Utilization System Transylvania County In accordance with your permit modification request received October 6,. 2011, and subsequent additional information received January 12, 2012, we are forwarding herewith Permit No. WQ0000731 dated February 15, 2012, to Lake Toxaway Company for the continued operation of the subject wastewater treatment and non -conjunctive reclaimed water utilization facilities. Modifications to the subject permit are as follows: ➢ Your permit's format has been updated to be consistent with the most current reclaimed water permit template, and rule references have been updated pursuant to the new 15A NCAC 02U rules that became effective July 18, 2011. ➢ Attachment B contains 13.52 acres of additional iTrigatiDn area (Holes 1-9). Previous Zone 01 has been removed from the attachment, since it is included in Fairways 12, 13, 15, and 16_ ➢ Condition 1.1. requires that plans and specifications for a recording flow meter be submitted to the Division by October 31, 2014. ➢ Condition I.2. requires that plans and specifications for a recording turbidity meter be submitted to the Division by October 31, 2014. ➢ Condition 1.3 _ requires that an evaluation of existing wet weather storage capacity and a plan for proper operation of the five-day upset pond shall be submitted to the Division by October 31, 2014. ➢ .-Condition II.14_b. lists setback requirements for wastewater treatment and storage units - These setbacks appeared in the previous permit dated August 27, 2003, but seem to have been .,A IT -JQUIFER PROTEiCT10N SECTICN . 636 Mail Selvice Center, Raleigh, North Carolina 27699-1636 ' :t2fication: 512`N. Salisbury St., Raleigh; North Carolina 27604 One > ne:919-897-64641 FAX: 919-807-6496 '- :�ri}ei: wurr�ncwatergual'lly.org lV NOlor rthC3r0l1n2.. Naturally y`{ 'Equal Oppc rlunity 1 Affirmalive Aclion Employer _ r Mr. Heinitsh February 15, 2012 Page 2 of 2 ➢ Condition VI.5. contains requirements to be met in the event that the property is transferred to a new owner. The Permittee shall not sell any portion of the wastewater disposal capacity without first obtaining another permitted disposal option. ➢ Attachment A — Requires increased fecal coliform monitoring (2 X Month), and requires grab samples to be taken for turbidity (5 X Week). On August 5, 2009, Session Law 2009-406, entitled "An Act to Extend Certain Government Approvals Affecting the Development of Real Property Within the State," was enacted by the General Assembly and signed into law. The Act, known as the Permit Extension Act of 2009, extends the expiration date of certain government approvals and permits. In 2010, this Act was extended by an additional year (S.L. 2010--177). Permit WQ0000731 falls within the scope of this Act and is therefore being extended until October 21, 2016. Per your permit, a renewal application must still be submitted six months in advance of the extended expiration date. This permit shall be effective from the date of issuance until October 31, 2016, shall void Permit No. WQ0000731 issued November 28, 2007, and shall be subject to the conditions and limitations as specified therein- Please pay particular attention to the monitoring requirements listed in Attachments A and B because they may differ from the previous permit issuance. Failure to establish an adequate system for collecting and maintaining the required operational information shall result in future compliance problems. For your convenience, customized electronic copies of your facility's NDMR and NDAR-1 reporting forms are available for download at: http://portal.ncdenr_orgJweb/wq/apsIlan/reporting. If any parts, requirements or limitations contained in this permit are unacceptable, the Permittee has the right to request an adjudicatory hearing upon written request within 30 days following receipt of this permit. This request shall be in the form of a written petition, conforming to Chapter 150B of the North Carolina General Statutes, and filed with the Office of Administrative Hearings at 6714 Mail Service Center, Raleigh, NC 27699-6714. Unless such demands are made, this permit shall be final and binding. If you need additional information concerning this matter, please contact Lori Montgomery at (919) 807-6336 or lori.montgomery@ncdenr.gov_ Sincerely, f _ harl Wakild, PE CC.' Transylvania County Health Department Asheville Regional Office, Aquifer Protection Section Paul Dow, PE — Altamont Environmental, Inc. (231 Maywood Street, Asheville, NC 2$801-2818) Permit File WQ0000731 Notebook File WQ0000731 NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES RALEIGH NON -CONJUNCTIVE RECLAIMED WATER UTILIZATION SYSTEM PERMIT In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules and Regulations PERMISSION IS HEREBY GRANTED TO Lake Toxaway Company Transylvania County FOR THE continued operation of the following reclaimed water generation system (with a total reclaimed water generation capacity — 20,000 gallons per day (GPD)): The collection system consists of septic tanks, a 15 gallon per minute (GPM) influent pump station with duplex grinder pumps, high water alarms, and approximately 2,750 linear feet of 1.5 inch force main_ The treatment system consists of a 5,000 GPD aerated surge tank, dual 20,000 -gallon aeration tanks, dual 3,395 -gallon clarifiers, dual 1,680 -gallon sludge holding tanks, four (4) 74 CFM blowers, a dual cell tertiary filter, a tablet chlorinator, a 520 -gallon chlorine contact tank, and a 100,000 -gallon five-day upset pond. continued operation of a 150,000 -gallon irrigation pond, a 300 GPM duplex irrigation pump station, and approximately 20.84 acres of existing golf course irrigation area (Holes 10-18); and approval to utilize reclaiMed water in the existing irrigation system located on 13.52 acres of additional golf course irrigation area (Holes 1-9); to serve Lake Toxaway Country Club, the Greystone Inn and onsite condominiums, with no discharge of wastes to surface waters, pursuant to the application received October 6, 2011, and in conformity with the project pians, specifications, and other supporting data subsequently fled and approved by the Department of Environment and Natural Resources and considered a part of this permit. This permit shall be effective from the date of issuance until October 31, 2016, shall void Permit No. WQ000731 issued November 28, 2007 and shall be subject to the following specified conditions and limitations: WQ0000731 Version 3.1 Sbell Version 120105 Page I of 9 Y. SCHEDULES 1. Plans and specifications for a recording flow measurement device shall be prepared by a licensed North Carolina Professional Engineer and submitted to the Division no later than October 31, 2014. At that time, this permit will be modified to include a compliance schedule for installation of the flow meter (90 days). 2. Plans and specifications for a recording turbidity meter shall be prepared by a licensed North Carolina Professional Engineer and submitted to the Division no later than October 31, 2014. At that time, this permit will be modified to include a compliance schedule for installation of the turbidity meter (90 days), and a turbidity limit (10 NTU maximum) will be added to the permit. 3. An evaluation of existing wet weather storage capacity and a plan for proper operation of the five-day upset pond shall be submitted to the Division no later than October 31, 2014. The evaluation and plan shall be prepared by a licensed North Carolina Professional Engineer and shall include plans and specifications for re -configuration of the five-day upset pond. At that time, this permit will be modified to include a compliance schedule for completion of the approved changes (no later than October 31, 2016). 4, In accordance with 15A NCAC 02T .0 116, upon completion of construction and prior to operation of the new reclaimed water irrigation areas for Holes 1-9, a certification (attached) shall be submitted from a licensed North Carolina Professional Engineer certifying that the permitted irrigation areas have been installed in accordance with this permit, Division approved plans and specifications, and other supporting documentation, including the location of all monitoring wells as applicable. If this project is to be completed in ,phases and partially certified. the Permittee shall retain the responsibility to track further construction approved under the same permit and shall provide a finalcertificate of completion once the entire project has been completed, Mail the Certification to the Division of Water Quality, Aquifer Protection Section, 1636 Mail Service Center, Raleigh, NC 27699-1636, 5. The Asheville Regional Office, telephone number (828) 296-4500, shall be notified at least 48 hours in advance (excluding weekends and holidays) of operation of the new reclaimed water irrigation areas such that an in-place inspection can be made if necessary_ Notification to the Aquifer Protection Section's regional supervisor shall be made from 8.00 a.m. until 5:00 p.m. on Monday through Friday, excluding State Holidays. 6. No later than six months prior to the expiration of this permit, the Permittee shall request renewal of this permit on official Division forms. Upon receipt of the request, the Division will review the adequacy of the facilities described therein, and if warranted, will renew the permit for such period of time and under such conditions and limitations as it may deem appropriate. Please note Rule 15A NCAC 02T .0105(d) requires an updated site map to be submitted with the permit renewal application H. PERFORMANCE STANDARDS The subject reclaimed water facilities shall be effectively maintained and operated at all times so there is no discharge to surface waters, nor any contravention of groundwater or surface water standards_ In the event the facilities fail to perform satisfactorily, including the creation of nuisance conditions due to improper operation and maintenance, or failure of the utilization areas to adequately assimilate the reclaimed water, the Permittee shall take immediate corrective actions including Division required actions, such as the construction of additional or replacement wastewater treatment and reclaimed water utilization facilities. WQ0000731 Version 3.1 Shell Version 120105 Page 2 of 9 3. The wastewater collection facilities shall be properly maintained and operated at all times, The Permittee shall maintain compliance with an individual system wide collection systems permit for the operation and maintenance of these facilities in accordance with 15A NCAC 02T .0400. If an individual permit is not required, the following performance criteria shall be met as provided in 15A NCAC 02T.0403. a. The sewer system shall be effectively maintained and operated at all times to prevent discharge to land or surface waters, and any contravention of groundwater or surface water standards. b. A map of the sewer system shall be developed and actively maintained. c. An operation and maintenance plan shall be developed, implemented and maintained_ d. Pump stations not connected to a telemetry system shall be inspected every day (i.e., 365 days per year). Pump stations connected to a telemetry system shall be inspected at least once per week. e. High-priority sewers shall be inspected at least once every six months. £ A general observation of the entire sewer system shall be conducted at least once per year. g. Overflows and bypasses shall be reported to the Asheville Regional Office in accordance with 15A NCAC 02B .0506(a), and public notice shall be provided as required per North Carolina General Statute §143-215.1C. h. A grease control program shall be developed, implemented and maintained. i. Right-of-ways and easements shall be maintained. j. Inspection and maintenance records for Conditions 1I.3.a. through II.3.i. shall be maintained for a period of at least three years, except for Conditions II.3.b. and TT -3.c., which shall be maintained for the life of the systern. 4. Effluent limitations for distributed reclaimed water shall not exceed those specified in Attachment A. 5. Application rates shall not exceed those specified in Attachment B. 6. The following shall be requirements for the reclaimed water distribution, storage and utilization facilities: a. All reclaimed water valves, storage facilities and outlets shall be tagged or labeled to warn the public or employees that reclaimed water is not intended for drinking. Where appropriate, such warning shall inform the public or employees to avoid contact with reclaimed water. b. All reclaimed water piping, valves, outlets and other appurtenances shall be color -coded, taped or otherwise marked to identify the source of the water as being reclaimed water. i. All reclaimed water piping and appurtenances shall be either colored purple (i.e., Pantone - 522) and embossed or integrally stamped or marked "CAUTION: RECLAIMED WATER — DO NOT DRINK" or be installed with a purple (Le_, Pantone 522) identification tape or polyethylene vinyl wrap. The warning shall be stamped on opposite sides of the pipe and repeated every three feet or less_ ii. Identification tape shall be at least three inches wide and have white or black lettering on purple (i.e., Pantone 522) field stating "CAUTION: RECLAIMED WATER — DO NOT DRINK." Identification tape shall be installed on top of reclaimed water pipelines, fastened at least. every 10 feet to each pipe length and run continuously the entire length of the pipe_ F,; 'r Z,r,-t;n „F•rier 1711111.3 (�ictr;i�ptlf7P qi,7�frM,, rF'frnfiltpd for t11P. r)jjMn.-''. of fllStribllfTm, JL c. All reclaimed water valves and outlets shall be of a type, or secured in a manner, that permits operation by authorized personnel only. WQ0000731 Version 3.1 Shell Version 120105 Page 3 of 9 d. Above -ground hose bibs (i.e., spigots or other hand -operated connections) shall not be present. Hose bibs shall be Iocated in locked below -grade vaults that shall be clearly, labeled non -potable. As an alternative to the use of locked below -grade vaults with standard hose bibs services, hose bibs, which can only be operated by a special tool or connected to a special hose connection, may be placed in non -lockable underground services boxes clearly labeled non -potable. 7. No direct cross -connections shall be allowed between the reclaimed water and potable water systems, unless such connection has been approved by the Department pursuant to 15A NCAC 18C .0406. 8. Reclaimed water distribution Iines shall be located 10 feet horizontally from and 18 inches below any water line where practicable. Where these separation distances cannot be met, the piping and integrity testing procedures shall meet water main standards in accordance with 15A NCAC 18C. 9. Reclaimed water distribution lines shall not be less than 100 feet from a well unless the piping and integrity testing procedures meet water :main standards in accordance with 15A NCAC 18C, but in no case shall they be less than 25 feet from a private well or 50 feet from a public well. 10. Reclaimed water distribution lines shall meet the separation distances to sewer lines in accordance with Rule .0305 of Subchapter 02T. 11. The compliance and review boundaries are established at the property boundary. Any exceedance of standards at the compliance or review boundary shall require action in accordance with 15A NCAC 02L.0106. 12. The Permittee shall apply for a permit modification to establish a new compliance boundary prior to any sale or transfer of property affecting a compliance boundary. 13. In accordance with 15A NCAC 02L .0107(d), no wells, excluding Division approved monitoring wells, shall be constructed within the compliance boundary except as provided for in 15A NCAC 02L .0107(g). 14. The facilities permitted herein shall be constructed according to the following setbacks: a_ The setbacks for reclaimed utilization sites shall be as follows (all distances in feet): i. Surface waters not classified SA: 25 ii. Surface waters classified SA: 100 iii. Any well with exception to monitoring wells: 100 b_ The setbacks for treatment and storage units shall be as follows (all distances in feet): i. Any well with exception of monitoring wells: 100 ii_ Any property line: 50 III. OPERATION AND MAINTENANCE REQUIREMENTS 1. The reclaimed water treatment and utilization facilities shall be properly maintained and operated at all times. The facilities shall be effectively maintained and operated as a non -discharge system to prevent the discharge of any reclaimed water or partially treated effluent resulting from the operation of this facility. TT-,,-., +1.,. Z?r_+r•• 7�nIT„t ter. (nnfrnl C�'cfF n� nPT-,•Ifnt-q (r'Ti1f atlnl (nm 71IS.".inT]'S CWTI( (1( i acdordance with 15A NCAC 08G .0200, and shall comply with all other conditions specified in the previously cited rules. j WQ0000731 Version 3.1 Shell Version 120105 Page 4 of 9 3. An operator certified by the Water Pollution Control System Operators Certification Commission (WPCSOCC) of a grade equivalent or greater than the facility classification shall be on call 24 hours per day. 4. A suitable year round vegetative cover shall be maintained on irrigation sites at all times, such that crop health is optimized, allows for even distribution of reclaimed water, and allows inspection of the reclaimed water irrigation system. 5. Adequate measures shall be taken to prevent reclaimed water ponding in or runoff from the reclaimed water irrigation sites. 6. Irrigation shall not be performed during inclement weather or when the ground is in a condition that will cause ponding or runoff. 7. All reclaimed water irrigation equipment shall be tested and calibrated at least once per permit cycle. Calibration records shall be maintained at the facility for a period of no less than five years, and shall be made available to the Division upon request. $. Only reclaimed water generated at Lake Toxaway Country Club shall be utilized in accordance with this permit. 9. Public access to the wastewater treatment facilities and five day upset pond shall be prohibited. 10. Public access to reclaimed water utilization sites shall be controlled during active site use. Such controls may include the posting of signs showing the activities being conducted at each site. 11. Diversion or bypassing of untreated or partially treated wastewater from the treatment facilities is prohibited. 12. Freeboard in the five-day upset pond and the irrigation pond shall not be less than two feet at any time. 13. Gauges to monitor waste/reclaimed water levels in the five day upset pond and the irrigation pond shall be provided. This gauge shall have readily visible permanent markings. 14. A protective vegetative cover shall be established and maintained on all earthen embankments (i.e., outside toe of embankment to maximum allowable temporary storage elevation on the inside of the embankment), berms, pipe runs, erosion control areas, and surface water diversions. Trees, shrubs, and other woody vegetation shall not be allowed to grow on the earthen dikes or embankments. Earthen embankment areas shall be kept mowed or otherwise controlled and accessible. 15. All effluent shall be routed to the five day upset pond should the limit for fecal coliform (e.g., daily maximum concentration of 25 colonies per 100 ml.,) or turbidity (e -g., instantaneous maximum of 10 NTU) be exceeded, until the problems associated with the wastewater treatment plant have been corrected. The wastewater in the five day upset pond shall be pumped back to the treatment plant headworks for re -treatment or treated in the five day upset pond prior to utilization. 16. The Pormittee shall develop and implement an education program to inform users (including employees) about the proper use of reclaimed water. Educational material shall be provided to all residents and/or other facilities provided with reclaimed water, and these materials shall be ihP. rerlairm(�ri water usee. X111 educational materials shall be made and/or employees about the use of reclaimed water, and that reclaimed water is not intended for drinking. Such notification shall be provided to employees in a language they can understand. WQ0000731 Version 3.1 Shell Version 120105 Page 5 of i 18. The residuals generated from the wastewater treatment facilities shall be disposed or utilized in accordance with 15A NCAC 02T .1100. The Permittee shall maintain a residual management plan pursuant to 15A NCAC 02U .0802. 19. Reclaimed water shall not be used for swimming pools, hot tubs, spas, or similar uses. 20. Reclaimed water shalt not be used for direct reuse as a potable water supply. IV. MONITORING AND REPORTING REQUIRMENTS I. Any Division required monitoring (including groundwater, plant tissue, soil and surface water analyses) necessary to ensure groundwater and surface water protection shall be established, and an acceptable sampling reporting schedule shall be followed. 2_ Per 15A NCAC 02H .0800, a Division certified laboratory shall conduct all laboratory analyses for the required effluent, groundwater or surface water parameters. 3. Flow through the reclaimed water generating facility shall be monitored, and daily average flow values shall be reported on Form NDMR. Until such time as a recording flow meter is installed, flow values shall be estimated using a time lapse camera in conjunction with pump read out in order to provide daily effluent flow estimates. 4. The Permittee shall monitor the reclaimed water from the generating facility at the frequencies and locations for the parameters specified in Attachment A. The Permittee shall maintain adequate records tracking the amount of reclaimed water utilized. Records shall be maintained for a minimum of five years. At a minimum, these records shall include the following information for each utilization site listed in Attachment l3: a. Date of reclaimed water utilization; b_ Site irrigated; c_ Length of time site is irrigated; d. Continuous weekly, monthly, and year-to-date hydraulic (inches/acre) loadings; c. Weather conditions; and f. Maintenance of cover crops. 6. Freeboard (i.e., waste/reclaimed water level to the lowest embankment elevation) in the five day upset pond and the irrigation pond shall be recorded weekly_ Weekly freeboard records shall be maintained at the facility for a period of no less than five years, and shall be made available to the Division upon request_ A record shall be maintained of all residuals removed from this facility. This record shall be maintained at the facility for a period of no less than five years, and shall be made available to the Division upon request_ At a minimum, this record shall include: a. Name of the residuals hauler; b. Non -Discharge permit number authorizing the residuals disposal, or a letter from a municipality agreeing to accept the residuals; c. Date the residuals were hauled; and d. Volume of residuals removed. WQ000073I Version 3.1 Shell Version I20105 Page 6 of 8. Three copies of all effluent monitoring data (as specified in Conditions N.3. and IVA.) shall be submitted on Form NDMR for each PPI listed in Attachment A. Reporting forms shall be submitted on or before the last day of the following month. If no reclaimed water distribution activities occurred during the monitoring month, monitoring reports documenting the absence of the activity are still required to be submitted. All effluent monitoring data shall be submitted to the following address: Division of Water Quality, Information Processing Unit, 1617 Mail Service Center, Raleigh, North Carolina, 27699-1617. 9. Three copies of all operation and utilization records (as specified in Conditions NS. and IV.6.) shall be submitted on Forth NDAR-1 for every non -conjunctive utilization site listed in Attachment B. Reporting forms shall be submitted on or before the last day of the following month. If no reclaimed water utilization activities occurred during the month, monitoring reports are still required documenting the absence of the activity. All information shall be submitted to the following address: Division of Water Quality, Information Processing Unit, 1617 Mail Service Center, Raleigh, North Carolina, 27699-1617. 10. Noncompliance Notification: The Permittee shall report by telephone to the Asheville Regional Office, telephone number (828) 296-4500, as soon as possible, but in no case more than 24 hours, or on the next working day following the occurrence or first knowledge of the occurrence of any of the following: a. Any occurrence at the facility resulting in the treatment of significant amounts of wastes that is abnormal in quantity or characteristic, including the known passage of a hazardous substance. b_ Any process unit failure (e.g., mechanical, electrical, etc.), due to known or unknown reasons, rendering the facility incapable of adequate wastewater treatment. c. Any failure resulting in a discharge of reclaimed water directly to surface waters. d. Any failure, due to known or unknown reasons, that renders the reclaimed water distribution line(s) incapable of adequately transporting the reclaimed water (e.g., mechanical or electrical failures, line blockages or breaks, etc.); e. Any time self-monitoring indicates the facilities permitted herein have gone out of compliance with the limitations contained in this permit. f Ponding in or runoff from the reclaimed water utilization sites. Any emergency requiring immediate reporting (e.g_, discharges to surface waters, imminent failure of a storage structure, etc.) outside normal business hours shall be reported to the Division's Emergency Response personnel at telephone number (800) 662-7956, (800) 858-0368, or (919) 733-3300. Persons reporting such occurrences by telephone shall also file a written report in letter form within five days following first knowledge of the occurrence. This report shall outline the actions takers or proposed to be taken to ensure the problem does not recur. V. I=NSPECTIONS 1. The Permittee shall provide adequate inspection and maintenance to ensure proper operation of the wastewater treatment and reclaimed water utilization facilities. 2_ The Permittee or their designee shall inspeci the wastewater treatment and reclaimed water utilization !inn (�,rilitz' &fC^ .rint-1,nn 2 Tic rll�ar jtnr t'TlnrS 3E SllliiTliT 1T1 ClISCIIRr<rP.S. Permittee shall maintain this inspection log for a period of Pave years from the date of the inspection, and this log shall be made available to the Division upon request_ WQ0000731 Version 3.1 Shell Version 120105 Page 7 of 9 3. Any duly authorized Division representative may, upon presentation of credentials, enter and inspect any property, premises or place on or related to, the wastewater treatment and reclaimed water utilization facilities' permitted herein at any reasonable time for the purpose of determining compliance with this permit; may inspect or copy any records required to be maintained under the terms and conditions of this permit, and may collect groundwater, surface water or leachate. samples. V1. GENERAL CONDITIONS 1. Failure to comply with the conditions and limitations contained herein may subject the Permittee to an enforcement action by the Division in accordance with North Carolina General Statutes 143- 215.6A to 143-215.6C. 2. This permit shall become voidable if the permitted facilities are not constructed in accordance with the conditions of this permit, the Division approved plans and specifications, and other supporting documentation. 3. This permit is effective only with respect to the nature and volume of wastes described in the permit application, Division approved plans and specifications, and other supporting documentation. No variances to applicable rules governing the construction or operation of the permitted facilities are granted, unless specifically requested and approved in this permit pursuant to 15A NCAC 02T .0105(n). 4. The issuance of this permit does not exempt the Permittee from complying with any and all statutes, rules, regulations, or ordinances, which may be imposed by other jurisdictional government agencies (e.g., local, state, and federal). Of particular concern to the Division are applicable river buffer rules in 15A NCAC 02B .0200; erosion and sedimentation control requirements in ' 15A NCAC Chapter 4 and under the Division's General Permit NCGO 10000; any requirements pertaining to wetlands under 15A NCAC 02B .0200 and 02H .0500; National Pollutant Discharge Elimination System (NPDES) requirements under 15A NCAC 02H .0 100, and documentation of compliance with Article 21 Part 6 of Chapter 143 of the General Statutes. 5. In the event the permitted facilities change ownership or the Permittee changes their name, a written permit modification request shall be submitted to the Division. This request shall be made on official Division forms, and shall include appropriate property ownership documentation and other supporting documentation as necessary. The Permittee of record shall remain fully responsible for maintaining and operating the facilities permitted herein until a permit is issued to the new owner. The Permittee shall not sell any portion of the wastewater disposal capacity without first obtaining another permitted disposal option. 6. The Permittee shall retain a set of Division approved plans and specifications for the life of the facilities permitted berei». Permit issued this the 15`h day of February, 2012 NORTH CAROLINA ENVIRONMENTAL MANAGEMEN COMMISSION �r arle akilrl_ P.F., Dire.ctr�r Permit Number WQ0000731 WQ0000731 Version 3.1 She11 Version 120105 page 8 of 9 Permit No. WQ0000731 Non -Conjunctive Reclaimed Water Utilization System Lake Toxaway Company February.15, 2012 Lake Toxaway Country Club Transylvania County ENGINEERING CERTIFICATION ❑ Partial ❑ Final In accordance with 15A NCAC 02T .0 116, I,_ , as a duly registered Professional Engineer in the State of North Carolina, having the Permittee's authorization to ❑ periodically ❑ weekly ❑ fully observe the construction of the permitted facility, hereby state to the best of my abilities that due care and diligence was used in the observation of the construction, such that the facility was built within substantial compliance and intent of this permit, the Division approved plans and specifications, and other supporting documentation. ❑ Any variation to this permit, the Division approved plans and specifications, and other supporting documentation has been documented in the attached as -built drawings, and shall serve as the Permittee's minor modification request to amend the permit accordingly. Provide a brief narrative description of any variations: Professional Engineer's Name Engineering Firm Mailing Address City Telephone E-mail i State Zip NC PE Seal, Signature & Date THE COMPLETED ENGINEERING CERTIFICATION, INCLUDING ALL SUPPORTING IN AND MATERIALS, SIIALL BE SENT TO THE FOLLOWING ADDRESS: NORTH CAROLINA DEPARTMENT OF ENVIRONMENT .AND NATURAL RESOURCES DIVISION OF WATER QUALITY AQUIFER PROTECTION SECTION LAND APPLICATION UNIT RALEIGH, NORTH CAROLINA 27699-1636 RALEIGH, NORTH CAROLINA 27604 WQ0000731 Version 3.1 Shell Version 120105 Page 9 of 9 THIS PAGE BLANK ATTACH,, - LIMITATIONS AND MONITORING REQUIREMENTS PPI 001 - EFFLI PCS Code Flow. Cotif. . Nitro Nitro BOIL. Solid. pH C41o; Turbi 50050 3t616 00610 00620 00310 00530 00400 50060 00076 -claimed Water Effluent to Distribution Permit Number: WQ0000731 Version.: 3.1 `-RACTERISTICS EFFLUENT LIMITS MONITORING REQUIREMENTS eter Description Monthly Average Monthly Geometric Mean Baily Minimum Daily Maximum Measurement Frequency Sam Sample P Type or thru treatment plant 20,000 GPD Daily Estimate 'SIF, M -FC Broth,44.5C : 14 #1100 mI 25 #/100 ml 2 X Month Grab nia Total (as N) 4 mg/1 6 mg/1 Monthly Grab Total (as N) Monthly Grab Deg. C) 10 mg/1 15 mg/l Monthly Grab -vended 5 mg/1 10 mg/1 Monthly Grab 6.0 S.U. 4.0 S.U. 5 X Week Grab Zesidual 5 X Week Grab T'urbidimiter 5 X Week Grab WQ0000731 .1 Attachment Pagel oil THIS PAGE BLANK ATTACH"' T APPROVED RECLAIMED WATER USES 1 Permit Number: WQ0000731 Version: 3.1 NON COT' ; Lake Tox.a, Zane 02 -DR -0 l 02 -FW -I1 02 -FW -12 II 02•FW-14 I 02 -FW -15 02 -FW -16 02 -FW -17 02 -FW- 18 02-T 1 D 02 -T -Il 02-T- 17 02-T-18 .FW1 and 9 FW2 FW3 FW4 FW6 73 and 8 T5 T6 T7 Totals WE LAND APPLICATION SITES apany - Lake Toxaway Country Club IRRIGATION ARTA INFORMATION APPLICATION LIMITATIONS ?wner County Co i Latitude Longitude Net Acreag e Dominant Soil Series Parameter kRate Rate Max Yearly Units Tway Company Transylvania 35°08`15° 82°5713" 1.63 Chester fine sandy loam 01284 - Non -Discharge Application Rate 0.31 13.79 inches 'way Company Transylvania 35°08'50" 82°56'59" 1.79 Chester fine sandy loam 01284 -Non -Discharge Application Rate 0.34 13.75 inches .way Company Transylvania i 35°07'55" 82056'58" 2.35 Chester fine sandy loam 01284 - Non -Discharge Application Rate 0.31 9.28 inches .way Company Transylvania 35°07'45" 82°56'51" 1.64 Chester fine sandy loam 01284 - Non -Discharge Application Rate 0.31 13.6 inches .way Company Transylvania 35007'51" 82057'05" 2.02 Chester fine sandy loam 01284 - Non -Discharge Application Rate 0.3 10.77 inches away Company Transylvania 35°0754" 82°57'14" 1.34 Chester fine sandy loam 01284 - Non -Discharge Application Rate 4.23 12.16 inches ,.way Company Transylvania 35°07'56" 82°5774" 1.87 Chester fine sandy loam 01284 - Non -Discharge Application Rate 0.27 10.42 inches ,.way Company Transylvania 35008'09" 82°57'20" 2.64 Chester fine sandy loam 01284 - Non -Discharge Application Rate 0.35 9.41 inches away Company Transylvania 35°08°15" 8205713" 1.11 Chester fine sandy loam 01284 - Nan -Discharge Application Rate 0.28 17.75 inches -.way Company Transylvania 35008'12" 82057'05" 1.62 Chester fzne sandy loam 01284 - Non-Dischargc Application Rate 0.25 11.08 inches :.way Company Transylvania 35°07'52" 82°57'17" 1.58 Chester fine sandy loam 01284 - Non -Discharge Application Rate 0.26 11.67 inches +way Company j Transylvania 35°08'03" 82°57'22" 1.25 Chester fine sandy loam 01284 - Nan -Discharge Application Rate 0.25 14.04 inches sway Company I Transylvania 35°08'18" 8257'22" 2.30 Fannin loam 01284 -Non, -Discharge Application Rate 0.222 13.93 inubcs sway Company Transylvania 35008'27" 82057`35" .68 Fannin loam 01284 - Non -Discharge Application Rate 0.15 32.00 inches ;way Company .way Company way Company sway Company .way Company :way Company sway Company Transylvania 3508'35" Transylvania 35008'41" Transylvania 35°08'32" Transylvania 35°08'30" Transylvania 35°08'40" Transylvania 35°08'39" Transylvania i 35008'27" 82057'30" 82°57'42" 82°57'46" 82057'38" 82°57'48" 82°57144" 82°57144" 3.07 1.06 1.33 .97 111 68 1.32 34.36 Fannin loam Fannin loam Fannin loam Fannin loam Fannin loam. Fannin loam Fannin loam 01284 - Non -Discharge Application Rate 01284 - Non -Discharge Application Rate 01284 -Non-Discharge Application Rate 01284 - Non -Discharge Application Rate 01284 - Non -Discharge Application Rate 01284 - Non -Discharge Application Rate 01284 -Ncn-Discharge Application Rate 0.23 0.19 0.23 0.21 0.24 0.15 0.23 10.97 26.25 24.99 31.26 16.55 32.40 25.29 inches inches inches inches inches inches inches WQ0000731 Attacnment 13 Page 1 of 1 THIS PAGE BLANK Tec..828.281.3350 Fnc.528.291.3351 LAKE TOXAWAY COMPANY www.altunontcnvimnmtnw.com LAKE TOXAWAY DRAWN BY: CHRIS GILBERT PROJECT MANAGER: 5TU RYMAN SCALE (FEET) TRANSYLVANIA COUNTY, NC CLIENT: LAKE TOXAWAY COUNTRY CLUB1,000 0 1,000 2,000 DATE: 6/13/07 - FILE PATH: P:�LUE Tommy C-1—CIMNGE ML%HG S 1-9 ND A—ZATiM 211A FIGl BREI - SITE LocA710I.no } SOURCE: • TREATMENT PL AERIAL PHOTOGRAPHY AND PROPERTY BOUNDARIES 30eoufcesraEer,esr LLE,Ni�"sne 628 T.I.AKE TOXAWAY COMA d. 628181.3330 Fay .2![ 33f1 FROM TRANSYLVANIA GIS I ACCESSED FEBRUARY 15, 2007, LAKE TOXAWAY DRAWN BY: CHRIS G3LBERT SCALE (FEET) TRANSYLVANIA COUNT PROJECT MANAGER. STU RYMAN CLIENT: LAKE TOXAWAY COUNTRY CLUB 50 25 0 50 100 DATE. 06/22/07 G:IProposaWLake TQXasv3ylGISTfGU7E77TR r, ,`'. 1 �• 0 0 � � ®. i - r > OJ"' S O V-0 Com. Ot 01, " `A /+ . ,�' ,�♦ '1�,;; i �'~'� �\ O .b, 'Aid - ^ k1 Sc S ` I ♦ EQ `.' l /-•r/i r ! ' ": Q f i ® ' F it IVA 0. Fes` / O it F r.• Jj r`r' /! htee #3 �.,'. \`'iI'�^ ^mow •' . i� �[ / ra Q. O.a,, _ �._^.�'-- _yr/.. I� i p J I \ '{�, a'. r•-di.a (�..r= STee #B 1 S. t DC7! I' i ` SFS IF 4 I`�` ...� ��_- F ' � �' t I m \ 1 1 f ---'tel '` 15�,� i S� r�r, ~Tee #5 O O if s' ® "',y i •! 1J�/ . . `'. !� _ ... O O rJi ,�-� ♦ ♦\_^_r r _..,- : ♦` •." h I 4k 0 0 IL t i�r t i %'• yj `\ Xt I f '`ht� 1 �` , _� S f tl' ��• 1pol�#7'� /� \``Y ^� rIr/ `� - • �I 14 ♦tS ,, {� 'L. ` ` ' �' / �� Z-».. * J j ♦ �1 tt % - / F i � �/^ ♦` I h �." rye ! 1 rS7{r' � �`� KY,�"`✓,' 1 _ • � \ ��t� � ��.i- �\ S, ."',,. �♦,` 1..s' r 1 ♦, t //)j 1 K i . \4 a .a i /�j•i..,cWI rri�� 1 + ." 1 .. �✓" ♦ \ , I �^•" '" ^.,, 7_0 \ _ =�`- O`�� s LEGEND REQUIRED SETBACKS DATA SOURCE& o Rain Bird AT700E--80-48 Rotors Mrom North Carolina Administrative Code Title 15A, Chapter 2, Field Verification----------------------- Water Supply Wells Rale Bird AT750E-80-48 Rotors Subchapter T Section .09121 Transylvania County GIS------------------ Building, Surface Water, and Parcel Lines p Rain Bird AT900E-80-4 Rotors Distance from wetted area: USGS Lake Toxaway SW Orthophotography-- Aerial Image for Setback Location 0 Rain Bird AT950E-80-30 Rotors Surface waters not classified SA - 25 feet Tri-State Pump Controls--------------- Irrigation Layout Any well except monitoring wells - 100 feet Monitoring Well ® Resldentlal Well ------- Wastewater Irrigation Setback PROPOSED WASTEWATER FIGURE —Surface Water 1 f ---Existing Irrigation Pipe ;. SPRAY IRRIGATION f Existing Residence aszHAYWooDST.,ASAr-82.LE1.335i of HOLES I-i ` Qa Hole Number or Putting Green iE1.628281.3350 FA0.628.281335! y� www.eltamouteavironmentai.cam -la Proposed Wastewater Spray Irrigation Area rDMV BY: CHAD HEARNSCALE (FEET) LAKE TOXAWAY COUNTRY CLUB Existing Parcel Lines PROJECT MANAGER: CHRIS GILBERT tw o ,ao zan LAKE TOXAWAY, NORTH CAROLINA C1IENT: LAKE TaXAWAY COMPANY REV. DATE DESaitpTION BY CHIC APV GATE: 05/17/2010 P:1LAKE To%AWAY COUNTRY CLIIIItFIG11NES\CAD\H0LE5 1-91PNOPOSEO WASTEWATER SPRAY IARJOATION.OWG A� AL r , 4380 r� �2 1 SS— 7- 9 >\ jFRE-ATMENf----7 �PLANT ANLL' LAGOONS -T- IRWA ry Yc:1 FAIRWWY 17 T E E 17 Ix/ 17 LEGEND SETBACK BUFFERS AND DRINKING WATER SUPPLY UNSUITABLE SOILS WELLS PROPERTY BOUNDARIES PROPOSED SPRAY 6 IRRIGATION ZONES SURFACE WATER BODIES V 1. BUILDINGS -FA-IRW-A Y-- '12 F. A IAI� . IRWAY F,& W,4 Y 14 SITE TOPOGRAPHY EXISTING SPRAY AREAS FIGURE 0 G � 0 4 231 Maywood Street, Asheville, NC 28801 TF-LB29.291.3350 FAc.828.281,3351 www.EatamontenviTo=cntaLcom LAKE TOXAWAY COMPANY DRAWN B% �LBERT LAKE TOXAWAY, 2 PROJECT STU RYMAN SCALE (FEET) TRANSYLVANIA COUNTY, NORTH CAROLINA CLIENT: L AY COUNTRY CLUB 250 0 250 500 DATE; f. FILE PATH: PALAKE TOXAWAY COUNTRY CLU81F1SURE51CAD1H0LE5 1-91PERMIT PACKA(3E\ FIGUREZ - ExisTm SPRAY AREAS.DwG