Loading...
HomeMy WebLinkAboutWQ0000539_Final Permit_19881005State of North Carolina Department of Natural Resources and Community Development Wilmington Regional Office James G. Martin, Governor S. Thomas Rhodes, Secretary Bob Jamieson DIVISION OF ENVIRONMENTAL MANAGEMENT October 5, 1988 CERTIFIED MAIL RETURN RECEIPT REQUESTED Mr. David Mohn, Owner D. J. Country Junction Route 1, Box 37 Stella, North Carolina 28582 Dear Mr. Mohn: 0 11 RECEIVED OCT 11 ma PERMITS & ENGINEERING Subject: Permit No. WQ0000539 D. J.'s Country Junction Septic Tank System To Serve One Bay Car Wash Carteret County In accordance with your permit application received August 1, 1988, and completed September 27, 1988, we are forwarding herewith Permit NO. WQ0000539, dated October 5, 1988 for the construction and operation of the subject wastewater treatment and disposal facility. This permit shall be effective from the date of issuance until rescinded and shall be subject to the conditions and limitations as specified therein. If any parts, requirements, or limitations contained in this permit are unacceptable to you, you have the right to an adjudicatory hearing before a hearing officer upon written request within thirty (30) days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 150B of the North Carolina General Statutes, and filed with the Office of Administrative Hearing, Post Office Drawer 11666, Raleigh, North Carolina 27604. Unless such demands are made, this permit shall be final and binding. 7225 Wrightsville Avenue, Wilmin�non, K.C. 28403-3696 • Telephone 919-256-4161 An Equal Opportuniry Affirmarive Action Employer Mr. David Mohn, Owner October 5, 1988 Page Two One (1) set of approved plans and specifications is being forwarded to you. If you have any questions or need additional information concerning this matter, please contact Mr. Ed Beck, telephone number (919) 256-4161. Sincerely, Original Signed By A. PRESTON HOWARD, 4R A. Preston Howard, Jr., P.E. Regional Supervisor APH:EB:mab Enclosure cc: Carteret County Health Department John P. Mclean Engineering Associates Permits and Engineering WiRO, CF NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT OF NATURAL RESOURCES AND COMMUNITY DEVELOPMENT P E R M I T For the Discharge of Sewage, Industrial Wastes or Other Wastes In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations: PERMISSION IS HEREBY GRANTED TO DAVID MOHN for the construction and operation of a 500 GPD wastewater treatment and disposal facility consisting of a grit chamber, a pump tank and oil/water separator, 1,000 gallon two compartment precast concrete septic tank, a distribution box, 240 linear feet of three feet wide nitritication trench, piping fittings and appurtenances to serve a one bay car wash at D. J.'s Country Junction with no discharge to surface waters of the State. This permit is granted pursuant to the application received August 1, 1988 and completed September 27, 1988 in conformity with the project plans, specifications, and other supporting data, subsequently filed and approved by the Department of Natural Resources and Community Development and considered a part of this permit. This permit shall be effective from the date of issuance until rescinded and shall be subject to the following specified conditions and limitations: 1. This permit shall become voidable unless the facilities are constructed in accordance with the approved plans, specifications and other supporting data. 2. This permit is effective only with respect to the nature and volume of wastes described in the application and other supporting data. Permit No. WQ0000539 Page Two 3. Adequate inspection, maintenance, and cleaning shall be provided by the permittee to insure proper operation of the subject facilities. 4. This permit is not transferable. 5. Upon the availability of a municipal or regional sewerage collection system, the subject wastewater treatment system shall be abandoned, and all wastewater discharged into the municipal or regional sewerage system. 6. This permit shall become voidable in the event of failure of the soil to adequately absorb the wastes, and may be rescinded unless the facilities are installed, maintained and operated in a manner which will protect the assigned water quality standards of the surface waters and groundwaters. 7. The Wilmington Regional Office, Phone No. 919/256-4161 shall be notified at least twenty-four (24) hours in advance of backfilling of the installed system so that an in-place inspection can be made of said system prior to backfilling. Such notification to the Regional Supervisor shall be made during the normal office hours from 8:00 a.m. until 5:00 p.m. on Monday through Friday, excluding State Holidays. 8. Any monitoring deemed necessary by the Division of Environmental Management to insure surface and groundwater protection will be established and an acceptable sampling reporting schedule shall be followed. 9. The sludge generated from these treatment facilities must be disposed of in accordance with the General Statutes 143-215.1 and in a manner approvable by the North Carolina Division of Environmental Management. 10. The wastewater treatment system shall be effectively maintained and operated at all times so that there is no discharge to the surface waters, nor any contamination of groundwaters which will render them unsatisfactory for normal use. In event the facilities fail to perform satisfactorily, including the creation of nuisance conditions, or failure of the irrigation area to adequately absorb the wastewater, the Permittee shall take such immediate corrective action as may be required by the Division of Environmental Management, including the construction of additional or replacement wastewater treatment or disposal facilities. Permit No. WQ0000539 Page Three 11. Diversion or bypassing of the untreated wastewater from the wastewater treatment system is prohibited. 12. The issuance of this permit shall not relieve the permittee of the responsibility for damages to surface or groundwaters resulting from the operation of this facility. 13. No traffic or equipment shall be allowed on the disposal area except while installation occurs or while normal maintenance is being performed. 14. An acceptable reserve area as indicated on the approved plans shall be maintained at all times. 15. A canopy shall be installed over the wash bay to restrict stormwater from entering the system. Permit issued this 5th day of October 1988. NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION Original Signed By q, PRESTON HOWARD, j R A. Preston Howard, Jr. Regional Supervisor Permit No. WQ0000539 ineer's Certification I , as a duly registered Professional Engineer in the State of North Carolina, hereby certify that construction of these permitted facilities has been completed in accordance with the approved plans and specifications. Signature Registration Number Date