HomeMy WebLinkAboutWQ0000295_Final Permit_19880915-+►Gild
«� 9ATr 4
State of North Carolina
Department of Natural Resources and Community Development
Division of Environmental Management
512 North Salisbury Street • Raleigh, North Carolina 27611
James G. Martin, Governor September. 15, 1988 R. Paul Wilms
S. Thomas Rhodes, Secretary Director
Mr. John Ferebee
Ryder Truck Rental, Inc.
P.0. Box 2586
Rocky Mount:, NC 27802
SUBJECT: Permit No. WQ0000295
Ryder Truck Rental_, Tnc,
Wastewater Treatment and Disposal System
Sewer Collection
Wake County
Dear Mr. Fer.e.bee:
In accordance with your application received May 25,- 1988, we are forwarOng
barewith Permit: No. WQ0000295, dated September 1.5, 1985, to Ryder Track Rental,
Inc. for the construction and operation of the subject wastc.►,;ate.r t.reatment and
disposal system.
T 1s permit shall he effective from the date of isslitlf'lti e 1. w it September 30,
J993, and 06 11 be subject to the conditions and limitations is specified there ta.
If any parts, requirements, or limitat%n4 =t:a.innx in Ais pe:rmi-t arc,
unacceptable to you, you have the right to '"Fql.lgst an nd j di.t ntory he'ari.Rg upon
written request: within 30 days following receipt of this permit. This request mus
be :in the form of a written petition, conforming to Ghaptov 1500 of North Carolina
General. Statutes, and filed with the Office of Admiaistrative He nr:inxs, post office
Drawer 11666, Raleigh, North Carolina 27604. Unless smch demands arc made this
permit small be final and binding.
One (l) scat of approved plans and specifications is fining forwarded to you. If
you need addi.ti.ona.l information concerning Lbi.s matter, rlon sr+ contact Mr. ,IaQ
Floyd, te,l.ephone No. 919/733-5083, ext. 549.
Si.ncer.n /
cc: Wake County Health Department,
Raleigh Regional Supervisor
Innovative &. Alternat ivo Systems, &c.
Dennis R. Ramsey
Pollu,im; Prevention Pats
P.Q Box 27687, Raleigh, North Carolina 276n-7687 Telephone 919-733-7015
An Eoual Oppomnity Affirmative Action Employer
NORTH CAROLINA
ENVIRONMENTAL MANAGEMENT COMMTSSTON
DEPARTMENT OF NATURAL RESOURCES AND COMMUNITY DEV1 1PPMENT
RALEIGH
PERMIT
For the discharge of Sewage, Industrial Wastes, or Other Wastes
In accordance with the provisions of Article 21 of Chapter_ 143, General SL.atutes
of North Carolina as amended, and other applicable Laws, Rules, and Regulations
PERMISSION IS HEREBY GRANTED TO
Ryder Truck Mental, Inc.
Waite County
FOR THE
construction and operation of a 500 GPD subsurface westavat:nr t;reatmant and disposal.
system consisting of a 1500 gallon oil/water separator, two 1500 gallon storage/pump
tanks with a 64 gpm simplex submersible pump, and approximately 600 1-Inear feet: of
conventional nitrification trench for subsurface disposal., with all associated
piping, valves, and appurtenances to serve the Ryder Truck Rental, Inc. facility
located in Garner, NC, pursuant to the application received May 25, 1988, and in
conformity with the project plan, specifications, and Mhor supporting data
Subsequently filed and approved by the Department of NaWral Resonrces and Community
Development and considered a part of this permit.
This permit shall by effective from the date of i.sfivance until September 30,
1993, and shall be subject to the following specified conditions nncd 1 i.m.iLati.ons:
I. This permit shall become voidable unless the faci 1 Ai.on are consLruc>d in
accordance with the approved plans, specifications, and otbnr supporting cdaLa.
2. This permit: is effective only with respect" to L.lie. nAt ure and volume of wastes
described in the application and other supporting data.
3. The facilities shall be properly maintained and ope.ratRd K ,all times.
4. This permit is not transferable.
5. Upon the availability of a municipal or regional sewerage collection system, the
subject wastewater treatment facilities sbaJA he abandoned and ill. wast: ,water
discharged into the municipal or regional sewerage system.
6. This permit shall become voidable in the event of failure of Lhe soil to
adequately absorb the wastes and may be rescinded unless the facilities are
installed, maintained, and operated in a manner which will. protect the assigned
water quality standards of the surface waters and ground waters.
7. In the event that the facilities fail to perform satisfactorily, includi.ag the
creation of nuisance conditions, the Permittee shall take such immediate
corrective action as may be required by this Division, including the construction
of additional or replacement wastewater treatment or disposal Facilities.
8. The Raleigh Regional Office, phone no. 919/733-2314 shall be. notified at least
twenty-four (24) hours in advance of backfilling of' the installed non -discharge
treatment system so that an in-place inspection can be made. Such notification
to the regional supervisor shall be made during the normal office hours from 8:00
a.m. until. 5:00 p.m. on Monday through Friday, excludiug State Holidays.
9. The sludge generated from these treatment facilities must be disposed of in.
accordance with General Statute 143215.1 and in n manner approvable by the [forth
Carolina Division of Environmental. Management.
10. The Permittee, at least six (6) months prior to the expi-ration of: this permit.,
shall request its extension. Upon receipt of the regnnst, the Commission will
review the adegr.tacy of the facilities described therein., grad if warranted, will.
extend the Permit for such period of time and under such conditions and
limitations as it may deem appropriate.
.1.1.. The application rates shall not exceed 0.3 gallons/square Boot/day.
12. The .issuance of this permit shall not relieve the Permi.t.teo of the responsibility
for damages to surface or g.roundwater.s r.esulLi..ng From the operation of this
facility.
13. The facilities shall he effectively maintained and opc-..r.atc.'d as a non -discharge
system to prevent the discharge of any wastewater resulting from the operation of
this facility.
14. No traffic or equipment shall be allowed on the disposal area except while
installation occurs or while normal_ maintenance is being performed.
1.5. Adequate :inspection, maintenance, and cleaning shall by provided by the Permi.tLoe
to insure proper operation of the subject facilities.
16. In any future transfer of this land, a notice shall aregiven to the new owner
that gives full details of the materials applied or incor-porKed at, this site.
17. An acceptable reserve area, equal in size to the approved disposal area, shall be
maintained at all times.
1.8. Solids, sludges, or other pollutant—, removed or- rc+sult.dng from thn wastewater
storage facilities shall be contained and disposed of in such a manner as to
E prevent any contamination of the surface or groundwaters of the State.
l
19. A copy of the approved plans and specifications shall be maintained on file by
the Permittee for a minimum of five years from the date of issuance.
20. The groundwater supply well located approximately 250 linear feetnasL of the
proposed disposal area, must be abandoned according to reg"Inn ions in 15 NCAG 2C,
prior to operation of the wastewater disposal system.
21.. Oil drained from engine crankcases or degreasing solvents wastes sh.a.11 not be
discharged into the wastewater disposal system.
22. Any additional groundwater quality monitoring ns deemed necessary by the
Department, shall be provided.
23. Upon completion of construction and prior to operation of this permitted
facility, a certification must be received from a Professional engineer
certifying that the permitted facility has been installed in accordance with the
approved plans and specifications. Mail the certf[i.caLion to the Permits and
Engineering Unit, P.O. Box 27687, Raleigh, N.C. 27611-7687,
Permit issued this the 15th day of September., 1988,
NORTH CAROLINA ENVIRONMENTAL 1:fAhKl;NfENT COMMISSION
s" R. Paul Wilms, Director
Divi.si.on of Fnj,ironmental Movagement
By Authority of Lige Environmental Management Commission
Permit No. WQ0000295
En ineer s Certification
I , as a duly registered Professional Engineer i.n. the
State of North Carolina, hereby certify that construction of these permitted
facilities has been completed in accordance with the approved plans and
specifications.
Signature Registration Number- Date---.-.-_-