HomeMy WebLinkAboutWQ0004367_Final Permit_19920819r
wp�
State of North Carolina
Department of Environment, Health and Natural Resources
Division of Environmental Management
512 North Salisbury Street • Raleigh, North Carolina 27611
James G. Martin, Governor A. Preston Howard, Jr., P.E..
William W. Cobey, Jr., Secretary Acting Director
August 19, 1992
Mr. Richard Pasin, President
Leland Resin Corporation
Post Office Box 1080
Leland, North Carolina 28451
Subject: Permit No. WQ0004367
Leland Resin Corporation
Cooling Water & Boiler Blowdown
Wastewater Spray Irrigation
Brunswick County
Dear Mr. Pasin:
In accordance with your permit amendment request received June 15, 1992, and your application
received November 6, 1990, we are forwarding herewith Permit No. WQ0004367 dated August 19,
1992, to Leland Resin Corporation for the modification of Groundwater monitoring parameters. Please be
advised that this permit is updated to conform to the current spray irrigation permit format, which includes
slight changes to some of the permit conditions. Also, permit condition II.7 has been corrected to reflect a
modified application rate.
This permit shall be effective from the date of issuance until March 31, 1996, and shall be subject
to the conditions and limitations as specified therein. Please pay particular attention to the monitoring
requirements in this permit. Failure to establish an adequate system for collecting and maintaining the
required operational information will result in future compliance problems. Issuance of this permit hereby
voids Permit No. WQ0004367 issued April 30, 1991.
If any parts, requirements, or limitations contained in this permit are unacceptable to you, you have
the right to request an adjudicatory hearing upon written request within 30 days following receipt of this
permit. This request must be in the form of a written petition, conforming to Chapter 150B of North
Carolina General Statutes, and filed with the Office of Administrative Hearings, P.O. Drawer 27447,
Raleigh, NC 27611-7447. Unless such demands are made this permit shall be final and binding.
Regional Offices
Asheville Fayetteville Mooresville Raleigh Washington Wilmington Winston-Salem
704/251-6208 919/486-1541 704/663-1699 919/571-4700 919/946-6481 919/395-3900 919/896-7007
Pollution Prevention Pays
P.O. Box 29535, Raleigh, North Carolina 27626-0535 Telephone 919-733-7015
An Equal Opportunity Affirmative Action Employer
If you need additional information concerning this matter, please contact W. John Seymour at 919/
733-5083.
Sincerely,
n.
r�
Y1.1. I4� 1
A. Presto Howard, Jr., P.E.
cc: Brunswick County Health Department
Wilmington Regional Office, Water Quality
Wilmington Regional Office, Groundwater
Groundwater Section, Jack Floyd
Training and Certification Unit
Andrew & Kuske Consulting Engineers, Inc.
Facilities Assessment Unit
NORTH CAROLINA
ENVIRONMENTAL MANAGEMENT COMMISSION
DEPARTMENT OF ENVIRONMENT, HEALTH AND NATURAL RESOURCES
RALEIGH
SPRAY IRRIGATION SYSTEM PERMIT
In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina
as amended, and other applicable Laws, Rules, and Regulations
PERMISSION IS HEREBY GRANTED TO
Leland Resin Corporation
Brunswick County
FOR THE
continued operation of a 9,060 GPD spray irrigation system for cooling water and boiler blowdown water
consisting of a 2,500 gallon storage tank, a 190 GPM pump station with high water alarms, approximately
450 linear feet of 3 inch force main, two spray irrigation heads to spray at a 90 foot radius on 30 inch
risers, an additional 400 linear feet of 3 inch force main and two additional spray heads (of same size) to
be added at a future date, and all associated valves, piping, and appurtenances to serve Leland Resin
Corporation with no discharge of wastes to the surface waters, pursuant to the application received
November 6, 1990, and in conformity with the project plan, specifications, and other supporting data
subsequently filed and approved by the Department of Environment, Health and Natural Resources and
considered a part of this permit.
This permit shall be effective from the date of issuance until March 31, 1996, and shall be subject
to the following specified conditions and limitations:
I. PERFORMANCE STANDARDS
1. The spray irrigation facilities shall be effectively maintained and operated at all times so
that there is no discharge to the surface waters, nor any contamination of ground waters
which will render them unsatisfactory for normal use. In the event that the facilities fail to
perform satisfactorily, including the creation of nuisance conditions or failure of the
irrigation area to adequately absorb the wastewater, the Permittee shall take such immediate
corrective action to correct the problem, including actions as may be required by the
Division of Environmental Management.
2. The issuance of this permit shall not relieve the Permittee of the responsibility for damages
to surface or groundwaters resulting from the operation of this facility.
3. The sludge generated from these treatment facilities must be disposed of in accordance with
General Statute 143-215.1 and in a manner approved by the North Carolina Division of
Environmental Management.
4. Diversion or bypassing of the untreated wastewater from the treatment facilities is
prohibited.
5. The following buffers shall be maintained:
a) 400 feet between -wetted area and any residence or places of public assembly under
separate ownership,
b) 150 feet between wetted area and property lines,
c) 100 feet between wetted area and wells,
d) 100 feet between wetted area and drainageways or surface water bodies,
e) 50 feet between wetted area and public right of ways,
f) 100 feet between wastewater treatment units and wells,
g) 50 feet between wastewater treatment units and property lines.
Some of the buffers specified above may not have been included in previous permits for
this waste treatment and disposal system. These buffers are not intended to prohibit or
prevent modifications, which are required by the Division, to improve performance of the
existing treatment facility. These buffers do, however, apply to modifications of the
treatment and disposal facilities which are for the purpose of increasing the flow that is
tributary to the facility. These buffers do apply to any expansion or modification of the
spray irrigation areas and apply in instances in which the sale of property would cause any
of the buffers now complied with, for the treatment and disposal facilities, to be violated.
The applicant is advised that any modifications to the existing facilities will require a permit
modification.
ITNEffif' ;: 1► :►1 U: leg I 51M,39181: 1 33510 ►
1. The facilities shall be properly maintained and operated at all times.
2. Upon classification of the facility by the Certification Commission, the Permittee shall
employ a certified wastewater treatment plant operator to be in responsible charge (ORC) of
the wastewater treatment facilities. The operator must hold a certificate of the type and
grade at least equivalent to or greater than the classification assigned to the wastewater
treatment facilities by the Certification Commission. The Permittee must also employ a
certified back-up operator of the appropriate type and grade to comply with the conditions
of Title 15A, Chapter $A, .0202. The ORC of the facility must visit each Class I facility at
least weekly and each Class II, III, and IV facility at least daily, excluding weekends and
holidays, and must properly manage and document daily operation and maintenance of the
facility and must comply with all other conditions of Title 15A, Chapter $A, .0202.
3. A suitable vegetative cover shall be maintained.
4. Irrigation shall not be performed during inclement weather or when the ground is in a
condition that will cause runoff.
5. Adequate measures shall be taken to prevent wastewater runoff from the spray field. If
runoff or excessive ponding result, then the permittee shall be required to install the
additional spray heads and /or reduce the flow.
6. The facilities shall be effectively maintained and operated as a non -discharge system to
prevent the discharge of any wastewater resulting from the operation of this facility.
7. The average annual weekly application rate shall not exceed 1.0 inches at an instantaneous
application rate that will not cause ponding or runoff.
8. No type of wastewater other than that from Leland Resin Corporation's Non -contact once
through cooling water of the chemical reactors and the boiler blowdown water shall be
sprayed onto the irrigation area.
2
IW
9. No traffic or equipment shall be allowed on the disposal area except while installation
occurs or while normal maintenance is being performed.
10. Public access to the land application sites shall be controlled during active site use. Such
controls may include the posting of signs showing the activities being conducted at each
site.
1. Any monitoring (including groundwater, surface water, soil or plant tissue analyses)
deemed necessary by the Division of Environmental Management to insure surface and
ground water protection will be established and an acceptable sampling reporting schedule
shall be followed.
2. Adequate records shall be maintained by the Permittee tracking the amount of wastewater
disposed. These records shall include, but are not necessarily limited to the following
information:
a) date of irrigation,
b) volume of wastewater irrigated,
c) field irrigated,
d) length of time field is irrigated,
e) continuous weekly, monthly, and year-to-date hydraulic (inches/acre) loadings for
each field,
f) weather conditions, and
g) maintenance of cover crops.
3. Three copies of all operation and disposal records (as specified in condition 1112) and all
effluent monitoring data and any other data as may be required shall be submitted on or
before the last day of the,following month to the following address:
NC Division of Environmental Management
Water Quality Section
Facility Assessment Unit
PO Box 29535
Raleigh, NC 27626-0535
4. Noncompliance Notification:
The Permittee shall report by telephone to the Wilmington Regional Office, telephone no.
919/ 395-3900, as soon as possible, but in no case more than 24 hours or on the next
working day following the occurrence or first knowledge of the occurrence of any of the
following:
a. Any occurrence at the wastewater treatment facility which results in the treatment of
significant amounts of wastes which are abnormal in quantity or characteristic, such
as the dumping of the contents of a sludge digester; the known passage of a slug of
hazardous substance through the facility; or any other unusual circumstances.
b. Any process unit failure, due to known or unknown reasons, that render the facility
incapable of adequate wastewater treatment such as mechanical or electrical failures
of pumps, aerators, compressors, etc.
3
i
C. Any failure of a pumping station, sewer line, or treatment facility resulting in a by-
pass directly to receiving waters without treatment of all or any portion of the
influent to such station or facility.
d. Any time that self -monitoring information indicates that the facility has gone out of
compliance with its permit limitations.
Persons reporting such occurrences by telephone shall also file a written report in letter
form within 15 days following first knowledge of the occurrence. This report must outline
the actions taken or proposed to be taken to ensure that the problem does not recur.
RNEWINITO ► 1 12410 01'16'14 0011113 DI u 1 DI ►
1. The three (3) existing monitor wells, required by the original permit, must be sampled
every February, June, and October for the following parameters:
Total Phosphorus TDS
TOC pH
Water Level Sulfates
Total Suspended Solids TKN
The measurement of water level must be made prior to sampling for the remaining
parameters.
The measuring points (top of well casing) of all monitoring wells shall be surveyed to
provide relative elevations of the measuring point for each of the monitoring wells. The
depth of water in each well shall be measured from the surveyed point on the top of the
casing.
If TOC concentrations greater than 10 mg/1 are detected in any downgradient monitoring
well, additional sampling and analysis must be conducted to identify the individual
constituents comprising this TOC concentration. If the TOC concentration as measured in
the background monitor well exceeds 10 mg/1, this concentration will be taken to represent
the naturally occurring TOC concentration. Any exceedances of this naturally occurring
TOC concentration in the downgradient wells shall be subject to the additional sampling
and analysis as described above.
The results of the sampling and analysis shall be sent to the N.C. Division of
Environmental Management on Form GW-59 (Compliance Monitoring Report Form) every
March, July, and November.
2. The Compliance Boundary delineated on the attached site plan for the disposal system is
specified by regulations in 15 NCAC 2L, Classifications and Water Quality Standards
applicable to the groundwater of North Carolina. An exceedance of Groundwater Quality
Standards beyond the Compliance Boundary is subject to penalty provisions applicable
under General Statute 143-215.6A. The sale of property, by the Permittee, which is within
or contiguous to the disposal system site may alter location of the Compliance Boundary.
For facilities permitted on or after December 30, 1983, the Compliance Boundary is
established at the lesser of 250 feet from the waste disposal area or 50 feet within the
property boundary.
If the title to any property which may affect the location of the Compliance Boundary is
changed, the permittee shall notify the Division Director within 14 days. The Director shall
then establish a modified Compliance Boundary which will be done as a modification to the
Permit.
4
The REVIE)y BOUNDARY delineated on the attached site map for the disposal system is
specified by regulations in 15 NCAC 2L, Groundwater Classifications and Standards. A
REVIEW BOUNDARY is established around disposal systems midway between the
Compliance Boundary and the perimeter of the waste disposal area. When the
concentration of any substance equals or exceeds the maximum allowable concentration of
that substance at the REYMW 50-MARY, as determined by monitoring, the permitme
shall either (i) demonstrate, through predictive calculations or modeling, that natural site
conditions, facility design and operational controls will prevent a violation of standards at
the Compliance Boundary; or, (ii) submit a plan for the alteration of existing site
conditions, facility design or operational controls that will prevent a violation of standards
at the Compliance Boundary, and implement that plan upon its approval by the Director.
3. Any additional groundwater quality monitoring, as deemed necessary by the Division, shalt
be provided.
1. Adequate inspection, maintenance, and cleaning shall be provided by the Permittee to
insure proper operation of the subject facilities.
2. The Permittee or his designee shall inspect the wastewater treatment and disposal facilities
to prevent malfunctions and deterioration, operator errors and discharges which may cause
or lead to the release of wastes to the environment, a threat to human health, or a nuisance.
The Permittee shall keep an inspection log or summary including at least the date and time
of inspection, observations made, and any maintenance, repairs, or corrective actions
taken by the Permittee. This log of inspections shall be maintained by the Permittee for a
period of three years from the date of the inspection and shall be made available upon
request to the Division of Environmental Management or other permitting authority_
3. Any duly authorized officer, employee, or representative of the Division of Environmental
Management may, upon presentation of credentials, enter and inspect any property,
premises or place on or related to the disposal site and facility at any reasonable time for the
purpose of determining compliance with this permit; may inspect or copy any records that
must be kept under the terms and conditions of this permit; or may obtain samples of
groundwater, surface water, or leachate.
1. This permit shall become voidable unless the facilities are constructed in accordance with
the conditions of this permit, the approved plans, specifications, and other supporting data.
2. This permit is effective only with respect to the nature and volume of wastes described in
the application and other supporting data.
3. This permit is not transferable. In the event there is a desire for the facilities to change
ownership, or there is a name change of the Permittee, a formal permit request must be
submitted to the Division of Environmental Management accompanied by an application
fee, documentation from the parties involved, and other supporting materials as may be
appropriate. The approval of this request will be considered on its merits and may or may
not be approved.
61
4. Failure to abide by the conditions and limitations contained in this permit may subject the
Permittee to an enforcement action by the Division of Environmental Management in
accordance with North Carolina General Statute 143-215.6A to 143-215.6C.
5. The issuance of this permit does not preclude the Permittee from complying with any and
all statutes, rules, regulations, or ordinances which may be imposed by other government
agencies (local, state, and federal) which have jurisdiction.
6. A set of approved plans and. specifications for the subject project must be retained by the
Permittee for the life of the project.
7. The annual administering and compliance fee must be paid by the Permittee within thirty
days after being billed by the Division. Failure to pay the fee accordingly may cause the
Division to initiate action to revoke this permit as specified by 15 NCAC 2H .0205 (c)(4).
8. The Permittee, at least six (6) months prior to the expiration of this permit, shall request its
extension. Upon receipt of the request, the Commission will review the adequacy of the
facilities described therein, and if warranted, will extend the permit for such period of time
and under such conditions and limitations as it may deem appropriate.
9. Issuance of this permit hereby voids Permit No. WQ0004367 issued April 30, 1991.
Permit issued this the 19th day of April, 1992.
NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION
A. Preston ward, Jr., P. ., Acting Direct
Division of Environmental Management
By Authority of the Environmental Management Commission
Permit Number WQ0004367
no