HomeMy WebLinkAboutWQ0002714_Final Permit_19960617State of North Carolina
Department of Environment,
Health and Natural Resources � � �
Division of Environmental Management
James B. Hunt, Jr., Governor ±L1
Jonathan B. Howes, Secretary ED H N
A. Preston Howard, Jr., P.E., Director
June 17, 1996
Mr. Michael Texter, Manager of Env. Compliance
AMP Incorporated
P.O. Box 3609, MS 081-005
Harrisburg, PA 17105-3608
Subject: Permit No. WQ0002714
AMP Incorporated
Young Phillips Facility, NC
Groundwater Remediation Facilities
Forsyth County
Dear Mr. Texter:
In accordance with a request, made by Mr. Stephen M. Ritz, P.G. of Roy F. Weston, Inc., to
relocate and change the size of the subject infiltration gallery, first made verbally in separate June 4, 1996,
meetings with representatives of the Division's Water Quality and Groundwater Sections and then
submitted in writing on, June 4, 1996, the Division is forwarding herewith Permit No. WQ0002714,
dated June 17, 1996, to AMP Incorporated for the construction and operation of the subject groundwater
remediation facility. This permit modification allows for the relocation of the subject infiltration gallery
approximately 170 west south west of the permitted location, and the changing the gallery size from 20
feet by 10 feet by 17 feet deep to 30 feet by 20 feet by 10 feet deep. Please note to reflect the gallery
relocation the following monitoring well sampling changes are included in this permit:
1. The permit sampling frequency at monitoring well MW-9 is to be increased from annually
to semi-annually, due to its location immediately downgradient of the new infiltration gallery
location. (permit condition IV.1)
2. Monitoring well MW-6 is to be removed from the sampling schedule due to its location and
the sustained absence of VOC's over the last four quarters. (permit condition IV.I)
3. Copies of a detailed topographic map of the site will be furnished to the Division's Water
Quality Section the the Groundwater Section prior to July 11, 1996. (permit condition IV.9)
This permit shall be effective from the date of issuance until May 31, 1998, shall void Permit No.
WQ0002714 issued April 24, 1996, and shall be subject to the conditions and limitations as specified
therein.
The Division understands that these modifications are acceptable to AMP, Inc., therefore this
permit is considered to be final and binding.
P.Q. Box 29535, Raleigh, Borth Carolina 27626-0535 Telephone 919-733-5083 FAX 919-733-9919
An Equal Opportunity Affirmative Action Employer 50% recycled/ 10% post -consumer paper
If you have any questions concerning the Groundwater Conditions or groundwater monitoring
requirements, please contact Mr. David Goodrich in the Groundwater Section at (919) 733-3221. If you
need any additional information concerning this matter, please contact Mr. John Seymour at (919) 733-
5083 ext. 544.
Sincerely, (n�
A. Presto Howard, Jr., E.
CC" Forsyth County Health Department
Weston, Inc.
Winston-Salem Regional Office, Water Quality Section
Winston-Salem Regional Office, Groundwater Section
Bob Cheek, Groundwater Section, Central Office
Training and Certification Unit (no rating change)
Facilities Assessment Unit
NORTH CAROLINA
ENVIRONMENTAL MANAGEMENT COMMISSION
DEPARTMENT OF ENVIRONMENT, HEALTH AND NATURAL RESOURCES
GROUNDWATER REMEDIATION PERMIT
In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as
amended, and other applicable Laws, Rules, and Regulations
AMP Incorporated
Forsyth County
FOR THE
construction of an additional recovery well and a new 3,200 cubic foot infiltration gallery to increase flow
of this facility to 47,520 GPD, and
continued operation of a groundwater remediation facility consisting of a total of five recovery wells with
pumps, dual air stripping towers designed at 20 gpm each, dual 160 gallon collective tanks, a 500 gallon
storage tank, a 20 GPM pump and a new 3,200 cubic foot infiltration gallery to serve AMP Incorporated's
Young Phillips Facility with no discharge of wastes to the surface waters, pursuant to the modification
request received June 4, 1996, and in conformity with the project plan, specifications, and other
supporting data subsequently filed and approved by the Department of Environment, Health and Natural
Resources and considered a part of this permit.
This permit shall be effective from the date of issuance until May 31, 1998, shall void Permit No.
WQ0002714 issued April 24, 1996, and shall be subject to the following specified conditions and
limitations:
I. PERFORMANCE STANDARDS
1. Upon completion of construction and prior to operation of this permitted facility, a
certification must be received from a professional engineer certifying that the permitted
facility has been installed in accordance with this permit, the approved plans and
specifications, and other supporting materials. Mail the Certification to the Water Quality
Permits and Engineering Unit, P.O. Box 29535, Raleigh, NC 27626-0535.
2, The Winston-Salem Regional Office, telephone number 910-771-4600, shall be notified at
least forty-eight (48).hours in advance of operation of the installed facilities so that an in -
place inspection can be made. Such notification to the regional supervisor shall be made
during the normal office hours from 8:00 a.m. until 5.00 p.m. on Monday through Friday,
excluding State Holidays.
3. This permit shall become voidable if the soils fail to adequately assimilate the wastes and
may be rescinded unless the facilities are installed, maintained, and operated in a manner
which will protect the assigned water quality standards of the surface waters and ground
waters.
4. In the event that the facilities fail to perform satisfactorily, including the creation of
nuisance conditions, the Permittee shall take immediate corrective action, including those
actions that may be required by this Division, such as the construction of additional or
replacement treatment or disposal facilities.
5 . The issuance of this permit shall not relieve the Permittee of the responsibility for damages
to surface or groundwaters resulting from the operation of this facility.
6. Any residuals generated from these treatment facilities must be disposed in accordance with
General Statute 143-215.1 and in a manner approved by the North Carolina Division of
Environmental Management.
7. Diversion or bypassing of the untreated groundwater from the treatment facilities is
prohibited.
II. OPERATION AND MAINTENANCE REQUIREMENTS
1. The facilities shall be properly maintained and operated at all times.
2. Upon classification of the facility by the Certification Commission, the Permittee shall
employ a certified wastewater treatment plant operator to be in responsible charge (ORC) of
the wastewater treatment facilities. The operator must hold a certificate of the type and
grade at least equivalent to or greater than the classification assigned to the wastewater
treatment facilities by the Certification Commission. The Permittee must also employ a
certified back-up operator of the appropriate type and grade to comply with the conditions
of Title 15A, Chapter 8A, .0202. The ORC of the facility must visit each Class I facility at
least weekly and each Class 11, Ill, and IV facility at least daily, excluding weekends and
holidays, and must properly manage and document daily operation and maintenance of the
facility and must comply with all other conditions of Title 15A, Chapter 8A, .0202. Once
the facility is classified, the Permittee must submit a letter to the Certification Commission
which designates the operator in responsible charge within thirty days after the wastewater
treatment facilities are 50% complete.
3. The facilities shall be effectively maintained and operated as a non -discharge system to
prevent the discharge of any wastewater resulting from the operation of this facility.
III, MONITORING AND REPORTING_ REQUIREMENTS
Any monitoring deemed necessary by the Division of Environmental Management to insure
surface and ground water protection will be established and an acceptable sampling
reporting schedule shall be followed.
2. Noncompliance Notification:
The Permittee shall report by telephone to the Winston-Salem Regional Office, telephone
number 910-771-4600, as soon as possible, but in no case more than 24 hours or on the
next working day following the occurrence or first knowledge of the occurrence of any of
the following:
a. Any occurrence at the wastewater treatment facility which results in the treatment of
significant amounts of wastes which are abnormal in quantity or characteristic, such as
the dumping of the contents of a basin or tank, the known passage of a slug of
hazardous substance through the facility, or any other unusual circumstances;
b. Any process unit failure, due to known or unknown reasons, that renders the facility
incapable of adequate wastewater treatment, such as mechanical or electrical failures of
pumps, aerators, compressors, etc.;
c. Any failure of a pumping station, sewer line, or treatment facility resulting in a by-pass
directly to receiving waters without treatment of all or any portion of the influent to
such station or facility; or
IV.
d. Any time that self -monitoring information indicates that the facility is not in compliance
with its permit limitations.
Persons reporting such occurrences by telephone shall also file a written report in letter
form within 15 days following first knowledge of the occurrence. This report must outline
the actions taken or proposed to be taken to ensure that the problem does not recur.
GROUNDWATER REQUIREMENTS
Nine of the existing monitor wells MW-1, MW-7, MW-S, MW-9, MW-13, MW-14, MW-
20, MW-23 and MW-24; and five groundwater recovery wells, MW-10, MW-22, MW-25,
MW-26 and MW-27 shall be sampled every January and July for the following parameters:
Water Level
pH
EPA Method 601
Five of the existing monitor wells MW-3, MW-5, MW-12, 1\4W-15, and MW-19 shall be
sampled annually ( at 12 month intervals) for the following parameters:
Water Level
pH
EPA Method 601
The measurement of water levels must be made prior to sampling for the remaining
parameters. The depth to water in each well shall be measured from the surveyed point on
the top of the casing.
All parameters that have been historically detected by EPA Method 601 shall be analyzed
for and reported.
The results of the sampling and analysis shall be sent to the Groundwater Section, Permits
and Compliance Unit, P.O. Box 29535 Raleigh, N.C. 27626-0535 on Form GW-59
[Compliance Monitoring Report Form] every February and August.
2. The influent and effluent from the treatment system shall be sampled every January, April,
July and October for the parameters specified below:
EPA Method 601
The results of the sampling and analysis shall be sent to the Groundwater Section, in the
Winston-Salem Regional Office within 30 days of sample collection.
3. Any additional groundwater quality monitoring, as deemed necessary by the Division, shall
be provided.
4. The COMPLIANCE BOUNDARY for the disposal system is specified by regulations in
15A NCAC 2L, Groundwater Classifications and Standards. An exceedance of
Groundwater Quality Standards at or beyond the Compliance Boundary is subject to
penalty provisions applicable under General Statute 143-215.6A(a)(1). The sale of
property, by the Permittee, which is within or contiguous to the disposal site, may alter the
location of the Compliance Boundary.
For facilities permitted on or after December 30, 1983, the Compliance Boundary is
established at the lesser of 250 feet from the infiltration gallery, or 50 feet within the
property boundary.
Any sale or transfer property which affects the location of the compliance boundary shall be
reported immediately to the Director. The permittee shall not transfer land within an
established compliance boundary unless the permittee has satisfied all the requirements of
15A NCAC 2L .107 (e and f).
The REVIEW BOUNDARY for the disposal system is specified by regulations in 15
NCAC 2L, Groundwater Classifications and Standards. A REVIEW BOUNDARY is
established around disposal systems midway between the Compliance Boundary and the
perimeter of the waste disposal area. When the concentration of any substance equals or
exceeds the maximum allowable concentration of that substance at the REVIEW
BOUNDARY, as determined by monitoring, the permittee shall either (i) demonstrate,
through predictive calculations or modeling, that natural site conditions , facility design and
operational controls will prevent a violation of standards at the Compliance Boundary; or,
(ii) submit a plan for the alteration of existing site conditions, facility design or operational
controls that will prevent a violation of standards at the Compliance Boundary, and
implement that plan upon its approval by the Director.
5. All components of the groundwater recovery, treatment, and disposal system shall be
properly weather -proofed to prevent freezing and failure of the system.
b. The groundwater recovery treatment and disposal system shall be inspected monthly. If it
is determined that the system is malfunctioning , all repairs should be made as soon as
possible and reported to the Winston-Salem Regional Office.
7. The existing infiltration gallery shall be removed from the treatment system's daily
operation. The existing trench shall be used as an emergency system. A shutoff valve
shall be installed to insure all flow will enter the new infiltration gallery. Should the
existing infiltration gallery ever be needed, AMP, Inc. shall notify the Winston-Salem
Regional Office 24 hours prior to any connection and operation, and provide the Regional
Office with the reason(s) for its operation and its anticipated duration.
8. Any abandonment of monitoring wells shall be performed in accordance with the
regulations set forth in 15A NCAC 2C .0113 (Abandonment of wells).
9. Copies of a detailed topographic map of the site will be furnished to the Division's Water
Quality Section the the Groundwater Section prior to July 11, 1996.
V . INSPECTIONS
1. Adequate inspection, maintenance and cleaning shall be provided by the Permittee to insure
proper operation of the subject facilities.
2. The Permittee or his designee shall inspect the groundwater recovery and treatment
facilities to prevent malfunctions and deterioration, operator errors and discharges which
may cause or lead to the release of wastes to the environment, a threat to human health, -or a
nuisance. The Permittee shall maintain an inspection log or summary including at Ieast the
date and time of inspection, observations made, and any maintenance, repairs, or corrective
actions taken by the Permittee. This log of inspections shall be maintained by the Permittee
for a period of three years from the date of the inspection and shall be made available to the
Division of Environmental Management or other permitting authority, upon request.
3. Any duly authorized officer, employee, or representative of the Division of Environmental
Management may, upon presentation of credentials, enter and inspect any property,
premises or place on or related to the disposal site or facility at any reasonable time for the
,purpose of determining compliance with this permit, may inspect or copy any records that
must be maintained under the terms and conditions of this permit, and may obtain samples
of groundwater, surface water, or leachate.
V 1. GENERAL CONDITIONS
Issuance of this permit does not constitute approval for reimbursement from the Leaking
Petroleum Underground Storage Tank Cleanup Funds (15A NCAC 2P).
2. This permit shall become voidable unless the facilities are constructed in accordance with
the conditions of this permit, the approved plans and specifications, and other supporting
data.
3. This permit is effective only with respect to the nature and volume of wastes described in
the application and other supporting data.
4. This permit is not transferable. In the event there is a desire for the facilities to change
ownership, or there is a name change of the Permittee, a formal permit request must be
submitted to the Division of Environmental Management accompanied by an application
fee, documentation from the parties involved, and other supporting materials as may be
appropriate. The approval of this request will be considered on its merits and may or may
not be approved.
5. A set of approved plans and specifications for the subject project must be retained by the
Permittee for the life of this project.
6. Failure to abide by the conditions and limitations contained in this permit may subject the
Permittee to an enforcement action by the Division of Environmental Management in
accordance with North Carolina General Statute 143-215.6(a) to 143-215.6(c).
7. The annual administering and compliance fee must be paid by the Permittee within thirty
(30) days after being billed by the Division. Failure to pay the fee accordingly may cause
the Division to initiate action to revoke this permit as specified by 15A NCAC 2H .0205
(e)(4).
8. The issuance of this permit does not preclude the Permittee from complying with any and
all statutes, rules, regulations, or ordinances which may be imposed by other government
agencies (local, state, and federal) which have jurisdiction.
9. The Permittee, at least six (6) months prior to the expiration of this permit, shall request its
extension. Upon receipt of the request, the Commission will review the adequacy of the
facilities described therein, and if warranted, will extend the permit for such period of time
and under such conditions and limitations as it may deem appropriate.
Permit issued this the 17th day of June, 1996
NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION
C
A. Preston ward, Jr., P.$., Director /
Division of vironrnental Management
By Authority of the Environmental Management Commission
Permit Number WQ0002714
5
Permit No. WQ0002714
June 17, 1996
ENGINEER'S CERTIFICATION
1, , as a duly registered Professional Engineer in the State of North
Carolina, having been authorized to observe (periodically, weekly, full time) the construction of the
project,
Project Name
Location
for the
Permittee hereby state that, to the best of my abilities, due care and diligence was used in the observation
of the construction such that the construction was observed to be built within substantial compliance and
intent of this permit, the approved plans and specifications, and other supporting materials.
Signature
Date
Registration No.
M