HomeMy WebLinkAboutWQ0000485_FP w Att C_20140326Afil-
NCDENR
North Carolina Department of Environment and Natural Resources
Division of Water Resources
Water Quality Programs
Pat McCrory Thomas A. Reeder John E. Skvarla, ill
Governor Director - Secretary
March 26, 2014
Mr. Jeff Baird — GeneraI Manager
Valley Proteins, Inc.
Post Office Box 1026
Rose Hill, North Carolina 28458
Subject: Attachment C Certification
Permit No. WQ0000485
Valley Proteins, Inc. — Rose Hill
Division
Spray Irrigation System
Duplin County
Dear Mr. Baird:
In accordance with your permit modification request received March 11, 2014, we are forwarding
herewith modified Attachment C, certified March 26, 2014 to Valley Proteins, Inc. for the subject
residuals program.
This .certification is being issued to modify Attachment C by: Removing Monitoring Well MW -
12A from the groundwater monitoring program. The area being monitored by this well is now being
monitored by active Monitoring Well MW -12B.
This modified Attachment C shall be effective from the date of certification until October 31,
2014 (i.e. expiration date of the current permit); shall void Attachment C of Permit No. WQ0000485 that
was previougly certified on November 22, 2012, and shall be subject to the conditions and limitations as
specified therein and well as those specified in the above -referenced permit. Please replace the
Attachment C of Permit No. WQ0000485 that was issued on November 22, 2012 with this modified
Attachment C.
It is the Permittee's responsibility to ensure that a complete permit is created by inserting
Attachment C into the previously issued permit.
If any parts, requirements, and/or limitations contained in this certification or modified
Attachment C are unacceptable, you have the right to request an adjudicatory hearing upon written
request within 30 days following receipt of the certification. This request shall be in the form of a written
petition, conforming to Chapter 150B of the North Carolina General Statutes and filed with the Office of
Administrative Hearings at 6714 Mail Service Center, Raleigh, North Carolina 27699-6714. Unless such
demands are made, this permit shall be final and binding.
WATER PERMITTING SECTION
1636 Mail Service Center, Raleigh, North Carolina 27699-1636
Locathn: 512 N. Salisbury St, Raleigh, North Carolina 27604
Phone, 91M07-6464 t FAX: 919 07-6496
Internet hitp:lipo4al.ncdenr.oralweWwolaps
An Equal Oppertunity t Affirmative Adon Employer
Mr. Baird
March 26, 2014
Page 2
Monitoring Well MW -12A should be permanently abandoned before June 1, 2014. Within 30
days of abandonment, a Well Abandonment Record (Form GW -30) listing this permit number and the
appropriate monitoring well identification number should be completed for the well and mailed to the
Division of Water Resources, Water Quality Permitting Section, 1636 Mail Service Center, Raleigh, NC
27699-1636. A North Carolina Certified Well Contractor should abandon the monitoring well according
to the North Carolina Well Construction Standards (ISA NCAC 02C .0113) and local county rules.
If you need any additional information concerning this matter, please contact David Goodrich at
(919) 807-6252 or by email at david.goodrich@ncdenr.gov.
Sincerely,
for eomas A. Reeder
cc: Duplin County Health Department
Washington Regional Office, Water Quality Regional Operations Section
Permit File WQ0000485
Notebook File WQ0000485
ATTACHMENT C — GROUNDWATER MONITORING AND LIMITATIONS Permit Number: WQ0000485 Version: 2.3
Monitoring wells: MW -1, MW -2, MW -4, MW -7A, MW -8A, MW -9, MW -10A, MW -11A, MW -12B, MW -13A, and MW -14A
GROUNDWATER CHARACTERISTICS
GROUNDWATER STANDARDS
MONITORING REQUIREMENTS
PCS Code
Parameter Description
Daily Maximum
Frequency Measurement
Sample Type
Footnotes
82546
Water level, distance from measuring point
Feet
3 X year
Calculated
1,2,3
00400
pH
6.5-8.5
Standard units
3 X year
Grab
1
31616
Coliform, Fecal MF, M
#1100 mL
3 X year
Grab
1
70300
Solids, Total Dissolved
500
mg/L
3 X year
Grab
1,6
00680
Carbon, Tot Organic (TOC)
mg/L
3 X year
Grab
1
00940
Chloride (as Cl)
250
mg/L
3 X year
Grab
1
00945
Sulfate, Total (as SO4)
250
mg/L
3 X year
Grab
1
00610
Nitrogen, Ammonia Total (as N)
15
mg/L
3 x year
Grab
1
00620
Nitrogen, Nitrate Total (as N)
mg/L
3 x year
Grab
1
00665
Phosphorus, Total (as P)
mg/L
3 x year
Grab
1
00929
Sodium, Total (as Na)
mg/L
3 x year
Grab
1
78732
Volatile Compounds, (GCIMS)
Presence of
Condition:Yes=l,
No=O
Annually
Grab
1,4,5
I. 3 x Year monitoring shall be conducted in March, July & November; annual monitoring shall be conducted every November.
2. The measurement of water levels shall be made prior to purging the wells. The depth to water in each well shall be measured from the surveyed point on the top of the casing. The measurement
of pH shall be made after purging and prior to sampling for the remaining parameters.
3. The measuring points (top of well casing) of all monitoring wells shall be surveyed to provide the relative elevation of the measuring point for each monitoring well. The measuring points (top
of casing) of all monitoring welts shall be surveyed relative to a common datum.
4. Volatile Organic Compounds (VOC) - in November only, analyze by one of the following methods:
a. Standard Method 62301), PQL at 0.5 pg/L or less
b. Standard Method 6210D, PQL at 0.5 µg/L or less
c. EPA Method 8021, Low Concentration, PQL at 0.5 µg/L or Iess
d. EPA Method 8260, Low Concentration, PQL at 0.5 pg/L or less
e. Another method with prior approval by the Aquifer Protection Section Chief
Any method used must meet the following qualifications:
a. A laboratory must be DWQ certified to run any method used.
b. The method used must, at a minimum, include all the constituents listed in Table VIII of Standard Method 6230D.
c. The method used must provide a PQL of 0.5 gg/L or less that must be supported by laboratory proficiency studies as required by the DWQ Laboratory Certification Unit. Any constituents
detected above the MDL but below the PQL of 0.5 ggJL must be qualified (estimated) and reported.
5. If any volatile organic compounds (VOC) are detected as a result of monitoring as provided in Attachment C, then the Winston-Salem Regional Office Aquifer Protection Supervisor, telephone
number (336) 771-5000, must be contacted immediately for further instructions regarding any additional follow-up analyses required.
6. If TOC concentrations greater than 10 mg/L are detected in any downgradient monitoring well, additional sampling and analysis must be conducted to identify the individual constituents
comprising this TQC concentration, If the TOC concentration as measured in the background monitor well exceeds 10 mg/L, this concentration will be taken to represent the naturally occurring
TOC concentration. Any exceedances of this naturally occurring TOC concentration in the downgradient wells shall be subject to the additional sampling and analysis as described above.
7. Monitoring wells shall be reported consistent with the nomenclature and location information provided in this attachment maps incorporated with this permit.