Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
NC0023973_Authorization to Construct_20180926
M KEAN MAFFITT WASTEWATER TREATME- NT PLANT UV DISINFECTION CONVERSION PROJECT McKim & Creed Project #07123 0002 FINAL DESIGN FOR REVIEW PURPOSES ONLY NOT RELEASED FOR CONSTRUCTION AUGUST 2018 -- SHEET INDEX 19 ;a _... 17 ` COVER i ND G 1 GENERAL NOTES AND LEGE .. C-1 EXISTING SITE AND DEMOLITION PLAN C-2 BASIN MODIFICATION PLAN }' C-3 PARTIAL PLANS, SECTIONS, AND DETAILS C-4 PARTIAL PLANS, SECTIONS, AND DETAILS C-5 C SE TIONS AND DETAILS E1 ELECTRICAL GENERAL NOTES SYMBOLS LEGENDS AND ABBREVIATIONS fir' J _.. ,_ �-.,„ ? ti ; ' .'� -- E2 EXISTING SINGLE LINE DIAGRAM DEMOLITION PLAN AND MODIFICATIONS 777- E3 NEW SINGLE LINE DIAGRAM z �r E4 POWER AND CONTROL RISER DIAGRAM 1 OF 3 J ° PROC SITE E T IT . � �. �_��� �. � �:��� - ___�__�__�,�< < _, E5 POWER AND CONTROL RISER DIAGRAM 2 OF 3 y r ttv z E6 POWER AND CONTROL RISER DIAGRAM 3 OF 3CHLORINE CONTACT ...r..w E7 ELECTRICAL SITE PLAN CHAMBER E8 � . ��� .� ���� ��� ���w�. a e r E8 ELECTRICAL POWER PLAN w � E9 ELECTRICAL GROUNDING PLA E10 ELECTRICAL LIGHTING PLAN E11 ELECTRICAL TYPICAL INSTALLATION DETAILS S-1 STRUCTURAL GENERAL NOTES, DESIGN LOADS, DESIGN CRITERIA + LEGEND S-2 STRUCTURAL EXIST. FACILITY TOP PLAN + UV MODIFICATIONS S-3 STRUCTURAL CANOPY ROOF FRAMING PLAN S-4 STRUCTURAL CANOPY ROOF FRAMING/ UV MODIFICATIONS SECTIONS AND DETAILS IITY MAP F TO SCALE D W 0 U) 0 W' 44 fill v E5 / 0 , SEAL � 025512 243 North Front Street 0 Wilmington, North Carolina 28401 �C N i i u ori "Y.. ADVANCING WATER Phone: (910)343-1048 , Fax: (910)251-8282 F- Stewardship. Sustainablility. Service. cn License: F-1222 D (D www.mckimcreed.com < NOTES: 1. ALL WORK SHALL COMPLY WITH APPLICABLE STATE, FEDERAL, AND LOCAL CODES, AND ALL NECESSARY LICENSES AND PERMITS SHALL BE OBTAINED BY THE CONTRACTOR AT HIS EXPENSE, UNLESS PREVIOUSLY OBTAINED BY THE OWNER AND PROVIDED AT THE PRE CONSTRUCTION CONFERENCE. 2. DEVIATION FROM THESE PLANS AND NOTES WITHOUT THE PRIOR WRITTEN CONSENT BY THE OWNER OR HIS REPRESENTATIVE OR THE ENGINEER MAY BE CAUSE FOR WORK TO BE UNACCEPTABLE. 3. ALL PIPE LENGTHS AND DISTANCES BETWEEN STRUCTURES ARE MEASURED FROM CENTER OF STRUCTURE TO CENTER OF STRUCTURE ALONG A HORIZONTAL PLANE. 4. ELEVATIONS SHOWN ARE BASED ON NAD83. 5. LOCATIONS OF EXISTING SHOWN UTILITIES ARE APPROXIMATE. IT 1S THE RESPONSIBILITY OF THE CONTRACTOR TO DETERMINE THE SIZE, DEPTH, MATERIAL, AND LOCATION OF ALL EXISTING UNDERGROUND UTILITIES PRIOR TO CONSTRUCTION AND TO TAKE WHATEVER STEPS ARE NECESSARY TO PROVIDE FOR THEIR PROTECTION. THE ENGINEER HAS ATTEMPTED TO LOCATE AND INDICATE ALL EXISTING UTILITIES ON THE PLANS; HOWEVER, THIS INFORMATION IS SHOWN FOR THE CONTRACTOR'S CONVENIENCE ONLY. THE ENGINEER AND THE OWNER ASSUME NO RESPONSIBILITY FOR THE LOCATIONS OF UTILITIES SHOWN OR NOT SHOWN. AT LEAST 48 HOURS PRIOR TO DIGGING ON OR OFF SITE THE CONTRACT R SHALL HAVE ALL UTILITIES FIELD LOCATED BY " NC ONE C 11 SYMBOL LEGEND Z7 FIRE HYDRANT LP YS LIGHT POLE PPCZPOWER POLE , 0 - ALL c ' GUY WIRE (1-800-632-4949) AND ALL OWNERS OF UTILITIES THAT DO NOT PARTICIPATE IN NC ONE -CALL. IT SHALL BE THE SOLE RESPONSIBILITY OF THE CONTRACTOR TO REPAIR AND/OR REPLACE ANY GAS VALVE AND ALL DAMAGE TO UTILITIES BY THE CONTRACTOR AT THE CONTRACTOR'S EXPENSE. QS SANITARY SEWER MANHOLE 6. THE CONTRACTOR SHALL NOTIFY THE ENGINEER IMMEDIATELY SHOULD ANY FIELD CONDITIONS SANITARY SEWER VALVE BE ENCOUNTERED THAT VARY FROM THE INFORMATION PROVIDED IN THE CONTRACT DOCUMENTS. -CO CLEANOUT 7. THE CONTRACTOR SHALL REMOVE AND REINSTALL ALL EXISTING FENCE AS REQUIRED FOR SIGN CONSTRUCTION. ANY ADDITIONAL FENCE MATERIALS REQUIRED SHALL BE PROVIDED BY THE DROP INLET CONTRACTOR AT NO ADDITIONAL COST TO THE OWNER. © STORM DRAIN MANHOLE 8. THE CONTRACTOR IS REQUIRED TO PROVIDE DETAILED VIDEO OR PHOTO DOCUMENTATION OF SITE CONDITIONS PRIOR TO MOBILIZATION. THE EXTENTS OF THE PROJECT SITE SHALL BE YARD LIGHT VIDEO/PHOTO DOCUMENTED INCLUDING, BUT NOT LIMITED TO: ALL ACCESS ROADS INTO AND OUT ELECTRIC HANDHOLE OF THE SITE, HAUL ROADS, EXISTING UTILITIES, STAGING AND STOCKPILE AREAS, CULVERTS, BRIDGES, DRAINAGE FEATURES, ADJACENT DRIVEWAYS, SIDEWALKS, ADJACENT STRUCTURES, El FIBER OPTIC PEDESTAL EXISTING FACILITIES, STREAM AND FLOODPLAINS ADJACENT AND IMMEDIATELY DOWNSTREAM OF THEF 0 FIBER OPTIC FLAG MARKER / PROJECT AREA, AND ANY OTHER AREAS THAT MIGHT POTENTIALLY BE IMPACTED BY CONSTRUCTION. VIDEOS AND PHOTOS SHALL HAVE THE DATES AND TIMES TAKEN DIGITALLY INDICATED. ALL oMB MAILBOX - DISTURBED AREAS SHALL BE RESTORED TO ORIGINAL CONDITION OR BETTER. VIDEO SHALL BE SUBMITTED TO THE ENGINEER PRIOR TO MOBILIZATION. CHECK DAM IRF IRON ROD FOUND 9. CONTRACTOR SHALL MAINTAIN AN APPROPRIATE DRIVEWAY FOR INGRESS/EGRESS TO PUMP STATION SITE AND MATERIAL STORAGE AREAS AT ALL TIMES. ® WATER METER N VALVE 10. THE CONTRACTOR SHALL PROVIDE ALL SURVEY WHERE NECESSARY FOR CONSTRUCTION. ANY 1- SIGN EXISTING STAKE OUT OR BENCHMARKS SHALL NOT BE USED BY THE CONTRACTOR. TREE 11. EROSION AND SEDIMENTATION CONTROL DEVICES SHALL BE INSTALLED ACCORDING TO NORTH CAROLINA SEDIMENT AND EROSION CONTROL STANDARDS AND AS DIRECTED BY THE ENGINEER. ALL TELEPHONE PEDESTAL DEVICES SHALL BE MAINTAINED SUCH THAT THEY FUNCTION AS INTENDED. AFTER COMPLETION OF ELECTRICAL METER BOX THE PROJECT THE CONTRACTOR SHALL REMOVE ALL EROSION CONTROL DEVICES WHERE A GOOD STAND OF GRASS HAS BEEN ESTABLISHED AND EROSION IS NO LONGER EVIDENT. REMOVAL OF THE REMAINDER OF THE EROSION CONTROL DEVICES SHALL OCCUR AS OTHER AREAS ARE STABILIZED. TREE UNE REMOVAL OF THE EROSION CONTROL DEVICES SHALL BE PERMITTED ONLY WITH THE PRIOR SILT FENCE APPROVAL OF THE ENGINEER. 30 CONTOUR 12. ALL AREAS DISTURBED BY GRADING, EXCAVATION, AND GENERAL CONSTRUCTION SHALL BE --�( SILT FENCE SEEDED, MULCHED, AND RESTORED IN ACCORDANCE WITH NORTH CAROLINA SEDIMENT AND EROSION CONTROL STANDARDS. - UNDERGROUND TELEPHONE LINE 13. THE CONTRACTOR SHALL NOT USE EXISTING SANITARY SEWERS AS A MEANS OF DEWATERING UNDERGROUND FIBER OPTIC LINE DURING CONSTRUCTION WORK. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL SURFACE WATER CHAIN LINK FENCE RUNOFF AND GROUND WATER FROM THE TRENCHES I AND SHALL PROVIDE NECESSARY DEWATERING AND PUMPING EQUIPMENT FOR HANDLING THESE FLOWS DURING CONSTRUCTION. DEWATERING UNDERGROUND GAS MAIN ACTIVITIES TO COMPLY WITH ALL FEDERAL, STATE, AND LOCAL LAWS. ANY ADDITIONAL PERMITS WATERLINE REQUIRED AS A RESULT OF DEWATERING ACTIVITIES ARE THE CONTRACTOR'S RESPONSIBILITY. ALL DEWATERING COSTS ARE CONSIDERED ANCILLARY TO THE COST OF WORK AND NO ADDITIONAL SEWER FORCE MAIN COMPENSATION WILL BE CONSIDERED FOR DEWATERING. EROSION CONTROL MEASURES SHOWN ON GRAVITY SEWER MAIN PLANS ARE DESIGNED FOR RAINFALL EVENTS ONLY AS PER NCDENR REGULATIONS. ADDITIONAL MEASURES REQUIRED TO CONTAIN/CONTROL DEWATERING ACTIVITIES AND ASSOCIATED DISCHARGES OVERHEAD ELECTRIC UNE SHALL BE THE SOLE RESPONSIBILITY OF THE CONTRACTOR AND INCLUDED IN THE COST OF THE UNDERGROUND ELECTRIC WORK. RIGHT OF WAY (SEE NOTE 18) 14. NO PIPE JOINT SHALL EXCEED PIPE MANUFACTURER'S MAX. ALLOWABLE LIMITS FOR DEFLECTION. 15. CONTRACTOR TO VERIFY SIZE, DEPTH, MATERIAL AND LOCATION FOR ALL UNDERGROUND UTILITIES PRIOR TO THE START OF CONSTRUCTION. TEST EXCAVATIONS TO DETERMINE SUCH INFORMATION SHALL BE DONE PRIOR TO CONSTRUCTION AT THE CONTRACTOR'S EXPENSE. 16. IT IS THE CONTRACTOR'S RESPONSIBILITY TO MAINTAIN DISTURBED STORM SEWERS DURING CONSTRUCTION. STORM DRAIN DAMAGE BY CONTRACTOR AS A RESULT OF CONSTRUCTION SHALL BE REBUILT TO ORIGINAL GRADE & CONDITION AT CONTRACTOR'S EXPENSE. 17. CONTRACTOR SHALL TEST EXCAVATE AS REQUIRED TO FIELD LOCATE WATER MAINS PRIOR TO CONSTRUCTION. CONTRACTOR SHALL INSTALL NEW FORCE MAIN WITH 10' MIN HORIZONTAL SEPARATION FROM ALL WATER MAINS. WHERE 10' HORIZONTAL SEPARATION IS NOT POSSIBLE, CONTRACTOR SHALL INSTALL NEW FORCE MAIN UNDER EXISTING WATER MAIN WITH 18" MIN VERTICAL SEPARATION. THIS SHALL BE INCLUDED IN THE COST OF WORK AND NO ADDITIONAL PAYMENT SHALL BE MADE. e_*'D �Ca e Fear i% 4 p 2 3 NORTH FRONT ST Public Utility Authority WILMINGTON, NORTH CAROLINA 28401 Stewardship. Sustainablf6ty. Service. TELE: (910) 343-1048 FAX: (910) 251-8282 LICENSE: F-1222 ep DATE: AUG 2018 SCALE: AS SHOWN f� J DRAWN BY: JPV CAPE EAR CHECKED BY- CARO, Y• CARO S/ S 552 P fill PUBLIC UTILITY AUTHORITY SOUTHSIDE UV DISINFECTION CONVERSION CAPE FEAR PUBLIC UTILITY AUTHORITY 235 GOVERNMENT CENTER DRIVE WILMINGTON, NC 28403 OFFICE: (910)332-6560 AWB PROJECT NO.: 7123-0002 'SHEET NO: � G-1 20' 0 20' 40' SCALE: 1"=20' (Approx) 01 GATE: AUG 2018 SCALE: AS SHOWN DRAWN BY: JPV P FE R CHECKED BY: PUBLIC UTILITY AUTHORITY AWB DESCRIPTIONDATE: .�``�CARO��''�.SOUTHSIDE UV PROJECT NO.: S! �'� 7123-0002 DISINFECTION CONVERSION SE = 2 2 °1-�-� CAPE FEAR PUBLIC UTILITY AUTHORITY 235 GOVERNMENT CENTER DRIVE WILMINGTON, NC 28403 OFFICE: (910)332-6560 SHEET NO: C-1 z ,lam t AERATION TANK —`- f`` SD so f l N AERATION f LOWERS I � Jrf ff ,f f rr � l _ ....,„� NOTES• \ 1.- ITEM TO BE DEMOLISHED. 2. CARRIER WATER PUMP: SD _ -�-- ss --.._._ ss SD ._ CUT DISCHARGE PIPE OFF BELOW GRADE AND CAP. s — ss-- REMOVE CONTROL STATION. os ss _ w4N REMOVE CONDUCTORS BACK TO SUPPLY PANEL AND CAP. SD N — S° - Yj PATCH CONCRETE WALKWAY AFTER CAPPING. 3. NPW SYSTEM: DEMOLISH PUMPS, PIPING AND PLATFORM. 0 CUT DISCHARGE PIPE OFF BELOW GRADE AND CAP. WALKWAY � ' _._.. - _�'A' REMOVE CONTROL STATION AND REMOVE CONDUCTORS BACK {TO REMAIN) TO SUPPLY PANEL AND CAP. REINSTALL SALVAGED HANDRAIL AND FENCING TO CLOSE GAP IN HANDRAIL AFTER NPW o (n SYSTEM REMOVAL. NON—PO BLE WATER SYS M (SEE NOTES) I EFFLUENT CHLORINE SAMPLE STORAGE BUILDING yy, y — DECH-LORtNATI01 v FACILITY "- (NOT SHOWN) --- --" 20' 0 20' 40' SCALE: 1"=20' (Approx) 01 GATE: AUG 2018 SCALE: AS SHOWN DRAWN BY: JPV P FE R CHECKED BY: PUBLIC UTILITY AUTHORITY AWB DESCRIPTIONDATE: .�``�CARO��''�.SOUTHSIDE UV PROJECT NO.: S! �'� 7123-0002 DISINFECTION CONVERSION SE = 2 2 °1-�-� CAPE FEAR PUBLIC UTILITY AUTHORITY 235 GOVERNMENT CENTER DRIVE WILMINGTON, NC 28403 OFFICE: (910)332-6560 SHEET NO: C-1 �u V, BASE SLAB I\ EL 2.4f U.V. SYSTEM N -2 `\ \ (VARIES TYP) . V FOR U.V. SYSTEM PARTA \ \ PLAN SEE SHEET C-3 ----------------- -- \ _FLOW _ ----- (TYP) ---- 36" DIP EF T PIPE n x x x x X 0 O CL O N N CID N O N 'nN N I O 05 T ! / C 00 O a c 'vII qKIN4&CREED Cape Fear >i 243 NORTH FRONT ST Public Utility Authority ADVANCING WATER WILMINGTON, NORTH CAROLINA 28401 Stewardship. Sustainablility. Service. nTELE: (910) 343-1048 N ^ FAX: (910) 251-8282 I N cn LICENSE: F-1222 EFFLUENT WEIR BOX REV: FLASH N � MIXER BASIN I' S N -- 1. SS SD SQ SS SS -- SS SS -- - SS S SS # t -NEW MOTOR OPERATOR=' -'-- ON EXISTING SLIDE., -DATE EXIST NG CONC ETE SIDEW LK (Y ) i �❑ — FLOW— — — // LIMITS OF N�:SILT FENCE 36" RCP MH #8 36" RCP DECHLORINATION FACILITY �-----.0OT SHOWN) 10' 0 10' 20' DATE: AUG 2018 SCALE: AS SHOWN DRAWN BY: SCALE: 1"=10' (Approx) JPV PE F R CHECKED BY - :DESCRIPTION DATE: S� i SEA I,� 9-111 111111111- PUBLIC UTILITY AUTHORITY AWB S O U T H S I D E UV PROJECT NO. DISINFECTION CONVERSION 7123-0002 CAPE FEAR PUBLIC UTILITY AUTHORITY 235 GOVERNMENT CENTER DRIVE WILMINGTON, NC 28403 OFFICE: (910)332-6560 SHEET NO: I C�2 «has, s x e �u V, BASE SLAB I\ EL 2.4f U.V. SYSTEM N -2 `\ \ (VARIES TYP) . V FOR U.V. SYSTEM PARTA \ \ PLAN SEE SHEET C-3 ----------------- -- \ _FLOW _ ----- (TYP) ---- 36" DIP EF T PIPE n x x x x X 0 O CL O N N CID N O N 'nN N I O 05 T ! / C 00 O a c 'vII qKIN4&CREED Cape Fear >i 243 NORTH FRONT ST Public Utility Authority ADVANCING WATER WILMINGTON, NORTH CAROLINA 28401 Stewardship. Sustainablility. Service. nTELE: (910) 343-1048 N ^ FAX: (910) 251-8282 I N cn LICENSE: F-1222 EFFLUENT WEIR BOX REV: FLASH N � MIXER BASIN I' S N -- 1. SS SD SQ SS SS -- SS SS -- - SS S SS # t -NEW MOTOR OPERATOR=' -'-- ON EXISTING SLIDE., -DATE EXIST NG CONC ETE SIDEW LK (Y ) i �❑ — FLOW— — — // LIMITS OF N�:SILT FENCE 36" RCP MH #8 36" RCP DECHLORINATION FACILITY �-----.0OT SHOWN) 10' 0 10' 20' DATE: AUG 2018 SCALE: AS SHOWN DRAWN BY: SCALE: 1"=10' (Approx) JPV PE F R CHECKED BY - :DESCRIPTION DATE: S� i SEA I,� 9-111 111111111- PUBLIC UTILITY AUTHORITY AWB S O U T H S I D E UV PROJECT NO. DISINFECTION CONVERSION 7123-0002 CAPE FEAR PUBLIC UTILITY AUTHORITY 235 GOVERNMENT CENTER DRIVE WILMINGTON, NC 28403 OFFICE: (910)332-6560 SHEET NO: I C�2 LOCAL D ISCONNECTING TROJAN PLAN NOTES: MEANs ANDUVSIGNA TM DO NOT SLOPE CHANNEL FLOOR. OVERCURRENT ° CHANNEL WIDTH & DEPTH MUST BE KEPT WITHIN A TOLERANCE OF PROTECTION DEVICE EQUIPMENT INTERCONNECTIONS (BY DESIGN BUILDER) No. DESCRIPTION FROM TO ANCHOR BOLTS ARE NOT SUPPLIED BY TROJAN TECHNOLOGIES, ° SYSTEM CONDUIT, WIRING, DISTRIBUTION PANELS & INTERCONNECTIONS 7 J \ 11 9,_4„ 1 POWER DISTRIBUTION CENTER (PDC)* DISTRIBUTION PANEL PDC(s) BY DESIGN BUILDER. 3 �� 11 POWER SUPPLY (DP) ELECTRICAL REQUIREMENTS SHOWN ARE TO SUPPLY TROJAN UV ON-LINE UV TRANSMITTANCE CONTROLLER 480Y/277V, 3 PHASE, 4 WIRE + GROUND (BY DESIGN BUILDER) EQUIPMENT ONLY. (LOCATION TO BE DETERMINED - 00 99 AMPS MAXIMUM CURRENT/PHASE (NOT SHOWN) REMOVABLE GRATING SECTIONS SHALL BE EASILY REMOVED BY ONE FOR MOUNTING DETAIL SEE SHEET C-5, 82.1 kVA/PDC POWER DRAW PERSON. MAXIMUM WEIGHT OF THE SECTIONS SHALL BE IN H S C MOUNT TO EXISTING HANDRAIL) — — 2 SYSTEM CONTROL CENTER (SCC)* DP SCC ACCORDANCE WITH REQUIREMENTS OF THE APPLICABLE JURISDICTION. POWER SUPPLY (NOT SHOWN) CONTRACTOR TO REVIEW ALL TROJAN TECHNOLOGIES INSTALLATION INTERCONNECT D ETA I L 120V, 1 PHASE, 2 WIRE + GROUND, 1.8 kVA INSTRUCTIONS PRIOR TO EQUIPMENT INSTALLATION. SCALE: NOT TO SCALE 13 EFFLUENT LEVELS SHOWN REFLECT HYDRAULICS ASSOCIATED WITH 3 HYDRAULIC SYSTEM CENTER (HSC) DP HSC NOT SHOWN TROJAN EQUIPMENT ONLY. 14 POWER SUPPLY 480V, 3 PHASE, 3 WIRE + GROUND, 2.5 kVA ( ) EFFLUENT LEVELS MAY BE ALTERED DUE TO CHANNEL DEBRIS OR 3' MIN.o GEOMETRY. CLEARANCE 15 4 BONDING CONDUCTOR PDC(s) UV BANK(s) SITE TO PROVIDE APPROVED (ENGINEERED) ANCHOR POINTS FOR REQUIRED 8 AWG TYPE TWH STRANDED (UNDERSIDE OF PANEL) PERSONNEL TO USE AS PART OF THEIR FALL RESTRAINT SYSTEM I I 5 UV INTENSITY UV BANK(s) PDC(s) AROUND OPEN CHANNELS. THE ANCHOR POINTS MUST BE POSITIONED ON-LINE UV TRANSMITTANCE SENSOR 4-2OmA ANALOG INPUT (UNDERSIDE OF PANEL) SO THAT THE PREFERRED RETRACTABLE LIFELINE OF 8 FEET IS OF z z (LOCATION TO BE DETERMINED) 6 BANK IN PLACE PROXIMITY SENSOR PROXIMITY SENSOR(s) PDC(s) SUFFICIENT LENGTH TO ACCESS THE WORK AT THE CHANNEL. II II � a 3 CONDUCTOR CABLES SUPPLIED *DESIGN BUILDER TO VERIFY DIMENSION BEFORE FABRICATION. II \ II � (SUPPLIED) (UNDERSIDE OF PANEL) **NEW HANDRAIL TO BE ALUMINUM WELDED TYPE. \ \ r7 Lij 0 FLOW METER LEVEL _ 7 MODBUS SCC HSC(s) & PDC(s) *** SENSOR AND TRANSMITTER o BELDEN 3106A OR EQUIVALENT UNDERSIDE OF PANEL COORDINATE LOCATION OF START SO AS TO NOT BE IMPACTED BY SERVICE TROUGH I I I ( ) STRUCTURAL BRACING. (BY DESIGN BUILDER) (LOCATION _ _ _ -�� I (LOCATION TO BE DETERMINED - (DAISY CHAINED) UV EQUIPMENT LAYOUT PER UV EQUIPMENT PROVIDER. (TYPICAL) II FOR MOUNTING DETAIL SEE SHEET C-5, 8 DISCRETE LOW LEVEL SIGNAL* LOW LEVEL SENSOR LEVEL SENSOR - — I MOUNT TO EXISTING HANDRAIL) 12 VDC - 2 CONDUCTORS CONTROL BOX (LVL) 9 DISCRETE WATER LEVEL SIGNAL LEVEL SENSOR PDC(s) WEIR PLATE 1 I \ T/EL. 8.35 I I 2 CONDUCTORS CONTROL BOX (LVL) (UNDERSIDE OF PANEL) 10 T/BOX LEVEL SENSOR CONTROL BOX (LVL)DP LEVEL SENSOR I \ EL. 10.76 POWER SUPPLY (BY DESIGN BUILDER) CONTROL BOX (LVL) 1 120V 1 PHASE 2 WIRE + GROUND 72 VA (NOT SHOWN) 5 7 7 11 FLOW METER FLOW METER PANEL SCC LOCAL DISCONNECTING 4 6 9 4-20 mA, DC ANALOG INPUT (NOT SHOWN) MEANS AND(BY DESIGN BUILDER) OVERCURRENT I I (BY DESIGN BUILDER) \ / K I! PROTECTION DEVICE TYP OF 3 OUT 12 ETHERNET/IP COMMUNICATION SCC PLANT SCADA TYP OF 3 UV BAN (BY DESIGN BUILDER) TYP OF 3 IN (BY OWNER) (NOT SHOWN) INTERCONNECT 13 ON-LINE UV TRANSMITTANCE ON-LINE UV SCC CONTROLLER SIGNAL TRANSMITTANCE D E TA I L PDC ON-LINE U VT DETAIL 4-20 mA CONTROLLER SCALE: NOT TO SCALEI 14 ON-LINE UV TRANSMITTANCE CONTROLLER* DP (NOT SHOWN) ON-LINE UV INTERCONNECT NOTE: TYPICAL FOR ALL UV BANKS. D ETA L.— FLASH I V I X B O X PLAN POWER SUPPLY (BY DESIGN BUILDER) TRANSMITTANCE TROUGH NOT SHOWN FOR CLARITY. SCALE:NOT TO SCALE SCALE: 3/8"=1'-0" 120V, 1 PHASE, 2 WIRE + GROUND, 0.2 kVA CONTROLLER NEW CONCRETE APRON 15 ON-LINE UV TRANSMITTANCE SENSOR ON-LINE UV ON-LINE UV (CCT -2 ONLY) 3' 4' 3' EXISTING CONCRETE APRON COMMUNICATION TRANSMITTANCE TRANSMITTANCE MATCH EXISTING (SENSOR CABLE PROVIDED BY HACH) SENSOR CONTROLLER FOR CHANNEL COVER AND GRATING * GROUND CONNECTION REQUIRED TO PLANT GRID (BY OTHERS). MODIFY EXISTING SEE STRUCTURAL DRAWINGS TRIM AND SECURE EXISTING HANDRAIL AS EQUIPMENT CANOPY NEW HANDRAIL HANPPAIL TO ACCOMMODATE NECESSARY TO (SEE STRUCTURAL DRAWINGS) WITH P END NEW HANDRAIL REMOVE EXISTING HANDWHEEL AND INSTALL NEW ACCOMMODATE MOTOR ACTUATOR ON EXISTING GATE STEM. CANOPY AND NEW CONCRETE STAIR*** INSTALLATION SHALL BE COMPLETE INCLUDING BUT NO WALL HEIGHT EXTENT OF NEW REMOVABLE HANDRAIL** LIMITED TO: MACHINING OF THRUST NUT, MOUNTING PLATE FOR EXISTING FLOOR ST _.._._ _..._.. __............__. _...._......_____.__... ____ AND, EACH AND M 0 D I FY ___ _eO _, _,_ __,_ STEM ETC. AS NECESSARY TO RECEIVE ACTUATOR +BANK 1 D � BANK le yBANK 1B BANK 1A �' (SEE NOTE 1 FOR ACTUATOR) LEVEL CONTROL WEIR OVERALL LENGTH NEW HANDRAIL** �..P OF 425.50» :.�, 9.90 REQUIRED FLOW CONDITIONER PLATE _ 122 FLOW REMOVABLE GRATING ... A (BY DESIGN BUILDER) A SCC SIZE AND LOCATION TO BE DETERMINED (INTERFACE SIDE POSITIONED AWAY FROM THE SUN) LEVEL SENSOR CONTROL BOX (LOCATION TO BE DETERMINED) LOWLEVEL SENSOR IC 8 11 11 \ 9 � 13 1001° ------------ z ------ HSC 2'-3" x 1'-10" FOOTPRINT REQUIRED FOUR (4) 1/2"0 ANCHORS REQUIRED No es. o 1. Actuator shall be: (AVMA SA14.6-75A/AM01.1,48OV/3PH/60 HZ, 4GTLS-16, 0/C TORQUE SWITCHES, SIDE MOUNTED HANDWHEEL, CAST IRON HOUSING, THERMALLY PROTECTED MOTOR, MATIC, REVERSING STARTER, POWER II - SUPPLY, LOGIC BOARD, INTERFACE, „ H/O/R, 0/S/C, 3 LIGHTS, DOUBLE SEAL, NEMA 4/6, MACHINED THRUST NUT, MOPDC 1 D PDC 1A 1C UNTING PLATE FOR EXISTING T T « FLOORSTAND. INTEGRAL LOCKABLE 00 UNFUSED DISCONNECT SWITCH, 3 -POLES) SERVICE TROUGH POWER DISTRIBUTION (BY DESIGN J CENTER (PDC) (TYPICAL) BUILDER) 37'-9" OVERALL LENGTH OF CONCRETE 3'-4"* -T- CHANNEL REDUCTION BAFFLE (BY DESIGN BUILDER) UV SYSTEM N O . 2 PARTIAL- PLAN VIEW SCALE: 3/8"=1 '-0" B Q447' ja'' v vMROW&OEED ADVANCING WATER 243 NORTH FRONT ST WILMINGTON, NORTH CAROLINA 28401 TELE: (910) 343-1048 FAX: (910) 251-8282 LICENSE: F-1222 Cape Fear Public Utility Authority Stewardship. Sustainablility. Service. REV: DESCRIPTION DATE: 2. PROVIDE ACTUATOR WITH FIELD CALIBRATION AND START UP SERVICES. PUBLIC UTILITY AUTHORITY SOUTHSIDE UV DISINFECTION CONVERSION CAPE FEAR PUBLIC UTILITY AUTHORITY 235 GOVERNMENT CENTER DRIVE WILMINGTON, INC 28403 OFFICE: (910)332-6560 Oe DATE: AUG 2018 SCALE: AS SHOWN DRAWN BY: JPV CHECKED BY: AWB PROJECT NO. 7123-0002 SHEET NO: C�3 1 EQUIPMENT CANOPY SEE STRUCTURAL DRAWINGS FOR DETAILS EQUIPMENT CANOPY ( ) (SEE STRUCTURAL DRAWINGS FOR DETAILS) 19'-10"CLEARANCE REQUIRED FOR CLEANING AND SERVICING CLEAR DISTANCE UNDER CANOPY -----7---- 7 z Z��' <_jv' > c��cW 0 Z ui TROJAN UVSIGNAT"" / / / / / / / / j Q oOr ^ of 24 LAMPS PER BANK / / / / w z HANDRAIL NOT SHOWN (TYP) / / / / Of PDC FOR CLARITY / / / / o SEE PLAN ON SHEET o C-3 FOR EXTENT BANK FRAME // // // / o o m 5 LO cYQ LEVEL CONTROL / / / / LLI FOR COVER/GRATING WEIR ALUMINUM PLANK** // // // //� ALUMINUM ,,, J SUPPORT LAYOUT REGULATED GRATING** Z AND DETAILS SEE NEW CONCRETE UPSTREAM a STRUCTURAL WL - 8.67' XZ DRAWINGS (SEE STRUCTURAL DRAWINGS) EL. =10.40' / / / / -i V)B C jh EL.=9.90 REGULATED ///� UPSTREAM z ..........._ AAlIR�! C�? PEAK FLOW m / ° ° d WL=8.15,WL=8.71' zZ d :. MINIMUM • w v EL.=7.69' REGULATED EXISTING WL=7.69' /� , // Q FLOATING COVER o SEE SHEET C-2 EFFLUENT PIPE o Z FOR EXTENT r g a : LOW / // / • m m � .... •.. :. 00 o // • // // o o FLOW CONDITIONER v' . COMPACTED SAND FILL d EL. x4.88' / / / • FLOW LLJ V) PLATE a d' PROPOSED / • // / I o TROJANUVSIGNAT"" .•..: :. a v .7 CONCRETE / // / . w d v d d BENCH // / 100 A o G ° .d d 4 e EL °• : ac ° ' a • A d 2.40 v a• d d a • ------------------ v •. v v d d a d � .dd d vd ' 'd d d d d.d• A4*' V d d d d d . Q d.d a ° d 2'-6" d vd ,d. _ °. d. _7'-11j" TO CENTER OF BANK A SUPPORT 2„ 5'-4" 2'-6" 3'-3" 5,_3„ 16,_6, 3'-4"* 33' B SECTION A SECTION - C3 C4 SCALE:3/8"=1'-0„ C3 C4 SCALE: 3/8"=1'-0" NOTE: PDC, HSC AND LOW LEVEL SENSOR NOT SHOWN FOR CLARITY LAMP CABLE AND SEE STRUCTURAL DRAWINGS HYDRAULIC HOSE FOR SUPPORT DETAILS STAGING AREA FOR AREA FOR HYDRAULIC WIPING PLAN NOTES: BANK TRANSLATION AND TRANSLATING (0.8"0 EACH) 3" RECOMMENDED OR (TOTAL OF FOUR (4) PER BANK) EL.=10.40' AS PER LOCAL CODE DO NOT SLOPE CHANNEL FLOOR. CHANNEL WIDTH & DEPTH MUST BE KEPT WITHIN A TOLERANCE OF -/+1j". jh EL. =10.40' AREA FOR LAMP CABLES a... ANCHOR BOLTS ARE NOT SUPPLIED BY TROJAN TECHNOLOGIES, (0.375"0 EACH) (TOTAL OF SYSTEM CONDUIT, WIRING, DISTRIBUTION PANELS & INTERCONNECTIONS BY DESIGN BUILDER. 24 LAMP CABLES PER BANK) a ° ` = . ELECTRICAL REQUIREMENTS SHOWN ARE TO 'SUPPLY TROJAN UV EQUIPMENT ONLY. °' REMOVABLE GRATING SECTIONS SHALL BE EASILY REMOVED BY ONE PERSON. SEE STRUCTURAL DRAWINGS MAXIMUM WEIGHT OF THE SECTIONS SHALL ' BE IN ACCORDANCE WITH A FOR SUPPORT DETAILS 14" MINIMUM d° REQUIREMENTS OF THE APPLICABLE JURISDICTION. TROUGH WIDTH OR CONTRACTOR TO REVIEW ALL TROJAN TECHNOLOGIES INSTALLATION AS PER LOCAL CODE INSTRUCTIONS PRIOR TO EQUIPMENT INSTALLATION. A D ET/AI L A EFFLUENT LEVELS SHOWN REFLECT HYDRAULICS ASSOCIATED WITH TROJAN EQUIPMENT ONLY. EFFLUENT LEVELS MAY BE ALTERED JUL TO CHANNEL DEBRIS OR GEOMETRY. 1 -4 SCALE: NOT TO SCALE SITE TO PROVIDE APPROVED (ENGINEERED) ANCHOR POINTS FOR PERSONNEL TO USE NOTE: TROUGH WIDTH BASED ON AS PART OF THEIR FALL RESTRAINT SYSTEM AROUND OPEN CHANNELS. THE ANCHOR NEC TABLE 392.22(A). POINTS MUST BE POSITIONED SO THAT THE PREFERRED RETRACTABLE LIFELINE OF 8 D ETA I L B ELECTRICAL ENGINEER TO DESIGN FEET IS OF SUFFICIENT LENGTH TO ACCESS THE WORK AT THE CHANNEL. SCALE:NOT TO SCALE CABLE ROUTING TO ADHERE TO *DESIGN BUILDER TO VERIFY DIMENSION BEFORE FABRICATION. LOCAL CODE **SEE STRUCTURAL DRAWINGS FOR EXTENT/LOCATION OF ALUMINUM PLANK AND GRATING ALONG WITH SUPPORT REQUIREMENT _ FFAR REV: DESCRIPTION DATE: vv �ED4 Cape Fear ADVANCING WATER 243 NORTH FRONT ST Public Utility Authority WILMINGTON, NORTH CAROLINA 28401 Stewardship. Sustainablility. Service. TELE: (910) 343-1048 FAX: (910) 251-8282 LICENSE: F-1222 CAPE FEAR PUBLIC UTILITY AUTHORITY 235 GOVERNMENT CENTER DRIVE WILMINGTON, INC 28403 OFFICE: (910)332-6560 DATE: AUG 2018 SCALE: AS SHOWN DRAWN BY: JPV CHECKED BY: AWB PROJECT N0. 7123-0002 'ISHEET NO: C-4 8„ 21-01, 3/8" NEOPRENE GASKET L W+ 12" 2.50 -- W FRP OR SST SUNSHADE 18» BOLTS, SHOP WELDED TO PLATE, COORDINATE SIZE AND LENGTH WITH TRANSDUCER OR TRANSMITTER MOUNTING REQUIREMENTS, TYP 4 PLACES TYP PANEL 1/2"0 SST EXPANSION ANCHOR AND BOLT, TYP 4 PLACES 3/16" 304 SST PLATE, TYP SECTION STANCHION 1.5xD OR WALL MOUNT COORDINATE HOLE LOCATIONS AND SIZES FRONT ELEVATION SECTION WITH TRANSDUCER OR TRANSMITTER MOUNTING, REQUIREMENTS NOTES 1 PANELS SHALL BE PROVIDED WITH SUNSHIELDS 2 SUNSHIELDS SHALL BE FRP, STYLE E AS MANUFACTURED BY O'BRI o CORPORATION, OR EQUAL, OR FABRICATED FROM 10 GAUGE TYPE 304 STAINLESS STEEL. WHERE PRACTICAL, PANELS AND INSTRUME 18" SHALL BE MOUNTED IN A NORTH FACING DIRECTION. o O 3 CONTRACTOR SHALL VERIFY PANEL SIZE BEFORE CONSTRUCTION 0 SUNSHIELDS AND MODIFY AS REQUIRED TO PROTECT PANELS FROM THE EFFECTS OF SOLAR HEAT GAIN. 4 SUNSHIELDS SHALL BE SUITABLE FOR WALL OR STAND MOUNTING. 3/16" 304 SST PLATE PLAN VIEW ULTRASONIC LEVEL TRANSDUCER SUNSHIELD FOR OUTDOOR PANELS WALL MOUNTING DETAIL DETAIL 1752001 REV: A_0%ne v C gV C'.IZEED W=Cape Fear ADVANCING WATER 243 NORTH FRONT ST Public Utility Authority WILMINGTON, NORTH CAROLINA 28401 Stewardship. Sustainability. Service. TELE: (910) 343-1048 FAX: (910) 251-8282 LICENSE: F-1222 NOTES: 1. WHEN NO CONCRETE IS AVAILABLE, POUR CLASS "B" CONCRETE SLAB, CHANNEL, SEE 30"00"x18"D MINIMUM. BASEPLATE PLAN 2. COAT ALUMINUM SURFACES IN CONTACT WITH CONCRETE IN ACCORDANCE I's NTS F 6" C14PANEL WITH DIVISION 9 REQUIREMENTS. `r = F-- / 6" 3. ALL BOLTS, NUTS, AND WASHERS SHALL BE TYPE 316 STAINLESS STEEL. SECTION STANCHION 1.5xD OR WALL MOUNT COORDINATE HOLE LOCATIONS AND SIZES FRONT ELEVATION SECTION WITH TRANSDUCER OR TRANSMITTER MOUNTING, REQUIREMENTS NOTES 1 PANELS SHALL BE PROVIDED WITH SUNSHIELDS 2 SUNSHIELDS SHALL BE FRP, STYLE E AS MANUFACTURED BY O'BRI o CORPORATION, OR EQUAL, OR FABRICATED FROM 10 GAUGE TYPE 304 STAINLESS STEEL. WHERE PRACTICAL, PANELS AND INSTRUME 18" SHALL BE MOUNTED IN A NORTH FACING DIRECTION. o O 3 CONTRACTOR SHALL VERIFY PANEL SIZE BEFORE CONSTRUCTION 0 SUNSHIELDS AND MODIFY AS REQUIRED TO PROTECT PANELS FROM THE EFFECTS OF SOLAR HEAT GAIN. 4 SUNSHIELDS SHALL BE SUITABLE FOR WALL OR STAND MOUNTING. 3/16" 304 SST PLATE PLAN VIEW ULTRASONIC LEVEL TRANSDUCER SUNSHIELD FOR OUTDOOR PANELS WALL MOUNTING DETAIL DETAIL 1752001 REV: A_0%ne v C gV C'.IZEED W=Cape Fear ADVANCING WATER 243 NORTH FRONT ST Public Utility Authority WILMINGTON, NORTH CAROLINA 28401 Stewardship. Sustainability. Service. TELE: (910) 343-1048 FAX: (910) 251-8282 LICENSE: F-1222 NOTES: 1. WHEN NO CONCRETE IS AVAILABLE, POUR CLASS "B" CONCRETE SLAB, CHANNEL, SEE 30"00"x18"D MINIMUM. BASEPLATE PLAN 2. COAT ALUMINUM SURFACES IN CONTACT WITH CONCRETE IN ACCORDANCE I's NTS F WITH DIVISION 9 REQUIREMENTS. `r ROUND CORNERS 3. ALL BOLTS, NUTS, AND WASHERS SHALL BE TYPE 316 STAINLESS STEEL. F5. 1 /2" RADIUS, TYP 4. APPLETON FSC CAST ALUMINUM BOX WITH FSK -1 VS COVER, OR EQUAL. REFER TO DETAIL 1752001 FOR SUNSHIELD DIMENSION REQUIREMENTS. IF TRANSMITTER REQUIRES SIDE ACCESS, CUT 6"HOLE IN SUNSHIELD WHERE ® SUNSHIELD FOR NECESSARY TO PROVIDE ADEQUATE ACCESS. OUTSIDE INSTALLATION 6. CONDUIT TYPE AND MATERIALS OF CONSTRUCTION FOR SUPPORTS AND SEE NOTE 5 HARDWARE SHALL BE AS REQUIRED FOR THE AREA IN WHICH IT IS INSTALLED. TRANSMITTER, FACING WHERE SHOWN, MOUNT INSTRUMENT TRANSMITTER/SUNSHIELD AND ASSOCIATED NORTH WHERE POSSIBLE 7or HARDWARE TO HANDRAIL. EXTEND SUNSHIELD AS NECESSARY TO SUPPORT/ATTACH SURGE PROTECTORS AND SWITCH. MOUNT SHIELD/INSTRUMENT c I TO HANDRAIL USING A MINIMUM OF 2 VERTICAL SECTIONS OF SST UNISTRUT. STRUT SHALL BE ATTACHED TO A MINIMUM OF 2 HANDRAILS AND SHALL EXTEND N 1 /2" LIQUID -TIGHT THE FULL HEIGHT OF THE SHADE. ELEVATION SHALL REMAIN A SHOWN HEREIN. FLEXIBLE METALLIC IT CONDO ALL STRUT FASTENERS AND HARDWARE SHALL BE SST. ' SEE NOTE 6 EL 120 VAC SURGE 11" � PROTECTOR SIGNAL SURGE PROTECTOR 9/16" HOLES, TYP O 00 3/4" CONDUIT STRAP, TYP a 114 MOUNTED AS REQUIRED SEE NOTE 6 AL CS 6x4.03 120 VAC WELDED TO PLATE O O DISCONNECT SEE NOTE 4 3/4" RIGID CONDUIT SEE NOTE 6 X 3/4" THICK-""Z" HICK BASE PLATE PLAN EN ALUMINUM PLATE 1 /2" DIA. ADHESIVE ANCHOR W/ MIN. 4" EMBED., TYP OF 4 " 3/4 1 -HOLE SCH 80 MIN. 3 1/2" TO EDGE OF CONC. ALUMINUM (AL) ALUMINUM STRAP BASEPLATE CHANNEL WITH CLAMP BACK SEE NOTE 2 GRADE OR FLOOR SEE NOTE 1 :• .• :. 1/4'1 BOLT 3/4" RIGID AND NUT CONDUIT FRONT VIEW SIDE VIEW CONDUIT STRAP PLAN DESCRIPTION DATE: 4 -WIRE TRANSMITTER MOUNTING DETAIL CARp,�N9,��� SS/ _= SEA = 5 PUBLIC UTILITY AUTHORITY SOUTHSIDE UV DISINFECTION CONVERSION CAPE FEAR PUBLIC UTILITY AUTHORITY 235 GOVERNMENT CENTER DRIVE WILMINGTON, NC 28403 OFFICE: (910)332-6560 DATE: AUG 2018 SCALE: AS SHOWN DRAWN BY: JPV CHECKED BY: AWB PROJECT NO. 7123-0002 SHEET NO: C-5 TYPICAL DEVICE SYMBOLS GENERAL ELECTRICAL SYMBOLS TYPICAL ABBREVIATIONS LIGHTING CONTROL SWITCH: NOTE: ALL ABBREVIATIONS MAY NOT BE UTILIZED FOR THIS PROJECT 4 A, AMP AMPERE CONTACT - NORMALLY CLOSED AFD ADJUSTABLE FREQUENCY DRIVE DESIGNATES CONCEALED, EXPOSED, ETC. NUMBERS/TEXT AFG ABOVE FINISHED GRADE CHARACTER "4" DENOTES SWITCH CONTROL AIT ANALYTICAL INDICATION TRANSMITTER THE GENERAL NOTES STATED ON THIS DRAWING ARE APPLICABLE TO ALL ELECTRICAL DRAWINGS AND WORK UNDER AHU AIR HANDLING UNIT AIC AMPERE INTERRUPTING CAPACITY , AL ALUMINUM D - DIMMER CONTROL ATS AUTOMATIC TRANSFER SWITCH OWNERS STANDARDS AND REQUIREMENTS. BKR BREAKER 4. C CONDUIT CONCEALED CONDUIT IN FLOOR SLAB, UNDERGROUND, ETC. CAB CABINET - - - - - - CB CIRCUIT BREAKER LP -1 CCTV CLOSED CIRCUIT TELEVISION CKT CIRCUIT ,�, CLG CEILING DUPLEX RECEPTACLE. CP CONTROL PANEL 600V RATED ELECTRICAL EQUIPMENT SHALL HAVE AN AMPERE INTERRUPTING CAPACITY (AIC) EQUAL TO OR CR CONTROL RELAY, CORROSION RESISTANT CS CONTROL SWITCH f Pr CV CONTROL VALVE VOICE (PHONE) OUTLET. CT CURRENT TRANSFORMER 0 CU COPPER TEMPERATURE SWITCH DETD DUAL ELEMENT TIME DELAY T SITE TELEPHONE EF EXHAUST FAN WIRING DEVICE NOTES: IF SHOWN, ELTU ELECTRONIC TRIP UNIT PROVIDE EQUIPMENT WHICH MEETS THE SPACE REQUIREMENTS. EMER EMERGENCY EMT ELECTRICAL METALLIC TUBING ENCL ENCLOSURE OUTLETS. IF SHOWN, LOWER -RIGHT EQUIP EQUIPMENT AL CONDUIT PREPARED WITH A RUBBER -BASED PRIMER COATING FOLLOWED BY WITH TWO SPIRAL, HALF -LAPPED EWC ELECTRIC WATER COOLER EWH ELECTRIC WATER HEATER EPRF EXPLOSION PROOF POWER MONITOR FA FIRE ALARM PM FAAP FIRE ALARM ANNUNCIATOR PANEL PILOT LIGHT - LETTER INDICATES COLOR FACP FIRE ALARM CONTROL PANEL O FLA FULL LOAD AMPS FVNR FULL VOLTAGE NON -REVERSING STARTER AS FLOUR FLUORESCENT MOTOR OVERLOAD RELAY' HEATERS FMC FLEXIBLE METALLIC CONDUIT FWE FURNISHED WITH EQUIPMENT VOLTMETER SWITCH GEN GENERATOR FS G, GND GROUND MOTOR SPACE HEATER GFIC GROUND FAULT CIRCUIT INTERRUPTER c - EXISTING SITE GROUND HH HANDHOLE PRESSURE SWITCH HID HIGH INTENSITY DISCHARGE CABLE -TRAY, BUS -DUCT, WIRE -WAY, TRENCH/FLOOR DUCT, RACEWAY, CONDUIT, ETC., THESE SHALL NOT BE HOA HAND -OFF -AUTO HP HORSE POWER M 0/C HPF HIGH POWER FACTOR JUNCTION BOX, SIZE PER NEC HPS HIGH PRESSURE SODIUM INSTALLATION. QUANTITY AND SIZING OF CONDUCTORS, CABLING, WIRING AND RESPECTIVE RACEWAYS DEPICTED ON THE CONTRACT HTR HEATER - HV HIGH VOLTAGE Hz HERTZ IMC INTERMEDIATE METALLIC CONDUIT (GALVANIZED) CONDUCTOR AND RACEWAY GROUPINGS IN COMPLIANCE WITH APPLICABLE CODES, STANDARDS AND SPECIFICATIONS JB JUNCTION BOX k THOUSAND BOTTOM NUMBER DENOTES FRAME SIZE. RIGHT NUMBER kCMIL THOUSAND CIRCULAR MILLS DISCONNECT SWITCH kA KILOVOLT AMPERE RACEWAY ROUTINGS SHALL BE ORGANIZED AND GROUPED IN A PRACTICAL MANNER TO MINIMIZE CROSS -OVERS kW KILOWATTS kWH KILOWATT-HOURS °) LED LIGHT -EMITTING DIODE CLASS 1 /DIVISION 1/11 LFMC LIQUIDTIGHT FLEXIBLE METAL CONDUIT RACEWAYS SHALL BE INSTALLED CONCEALED UNLESS OTHERWISE NOTED OR SHOWN. THESE SHALL RUN PARALLEL LFNC LIQUIDTIGHT FLEXIBLE NONMETALLIC CONDUIT LIT LEVEL INDICATION TRANSMITTER ® LP LIGHTING PANEL, LIGHT POLE 11;:71 OF 3R LTG LIGHTING ° p MCB MAIN CIRCUIT BREAKER GROUND ROD MCC MOTOR CONTROL CENTER MCP MOTOR CIRCUIT PROTECTOR MDP MAIN DISTRIBUTION PANEL o� O MFR MANUFACTURER MH MANHOLE 042000 MLO MAIN LUGS ONLY ❑ LOCATED AT FIELD DEVICE MSB MAIN SWITCHBOARD RACEWAY AND WIRING FOR LIGHTING, RECEPTACLES AND BRANCH CIRCUITS ARE NOT TYPICALLY SHOWN ON THE MTD MOUNTED/MOUNTING MTS MANUAL TRANSFER SWITCH MV MEDIUM VOLTAGE O MOUNTED ON DOOR NEC NATIONAL ELECTRIC CODE PULL STRING. N, NEU NEUTRAL 20. NA NOT APPLICABLE NC NORMALLY CLOSE W/MOUNTING RACK NO NORMALLY OPEN ° ° NIC NOT IN CONTRACT ° ° NTS NOT TO SCALE SYMBOLS NOT SHOWN ON THIS DRAWING MAY P POLE BE SHOWN ELSEWHERE PA PUBLIC ADDRESS DEVICE MOUNTING HEIGHTS PB PULL BOX, PUSH-BUTTON 27 UNDER PCP PUMP CONTROL PANEL TO DEVICE TOP UNLESS NOTED OTHERWISE. PF POWER FACTOR RECEPTACLES (INTERIOR PROCESS AREAS) - 16" AFF �, PH PHASE 46 PHASE PIT PRESSURE INDICATION TRANSMITTER 48" AFF PLC PROGRAMMABLE LOGIC CONTROLLER PHONE OUTLETS 16" AFF PNL PANEL 49 OVER TEMPERATURE ' 87 DIFFERENTIAL PP POWER PANEL, POWER POLE MOUNTED EQUIPMENT SPANNING DISTANCES 48" AND GREATER IN LENGTH OR 36" AND GREATER IN DEPTH. PT POTENTIAL TRANSFORMER 51 TIMED PWR POWER 1® TIMED REC RECEPTACLE NOTES: RVSS REDUCED VOLTAGE SOFT STARTER REQ REQUIRED m RM ROOM SYMBOLS NOT SHOWN ON THIS DRAWING MAY BE SHOWN RMC RIGID METAL CONDUIT (GALVANIZED) o RTU REMOTE TELEMETRY UNIT INCLUDE THE SCADA SUPERVISORY CONTROL AND DATA ACQUISITION a SH SHEET 00 SPEC SPECIFICATION SS SELECTOR SWITCH s SST STAINLESS STEEL STP SHIELDED TWISTED PAIR SW SWITCH 3 SWBD SWITCHBOARD N SWGR SWITCH GEAR o TEL TELEPHONE M T -M THERMAL -MAGNETIC n TYP TYPICAL 01 UG UNDERGROUND UH UNIT HEATER i UON UNLESS OTHERWISE NOTED s UTIL UTILITY i UTP UNSHIELDED TWISTED PAIR V VOLTS m VFD VARIABLE FREQUENCY DRIVE W WIRE, WATT WH WATT-HOUR o WP WEATHERPROOF o XFMR TRANSFORMER N 0 i M N 0 TYPICAL DEVICE SYMBOLS GENERAL ELECTRICAL SYMBOLS a $ LIGHTING CONTROL SWITCH: GENERAL ELECTRICAL SYMBOLS 4 UPPER -LEFT CHARACTER "a" DENOTES CONDUIT' HOMERUN TO EQUIPMENT SHOWN. LINE TYPE CONTACT - NORMALLY CLOSED REFERENCE ALL SPECIFICATIONS AND CONTRACT DRAWINGS FOR ADDITIONAL REQUIREMENTS AND CONTRACT SWITCH DESIGNATION. LOWER -RIGHT DESIGNATES CONCEALED, EXPOSED, ETC. NUMBERS/TEXT RESPONSIBILITIES PRIOR TO COMMENCING WORK. CHARACTER "4" DENOTES SWITCH CONTROL DESIGNATE HOMERUN EQUIPMENT (I.E. PANEL BOARD CONTACT -NORMALLY OPEN THE GENERAL NOTES STATED ON THIS DRAWING ARE APPLICABLE TO ALL ELECTRICAL DRAWINGS AND WORK UNDER 3 - THREE-WAY SWITCH CONTROL CIRCUIT NUMBER). CONTRACT UNLESS NOTED OTHERWISE. 4 - FOUR-WAY SWITCH CONTROL , THREE POSITION SELECTOR SWITCH ALL ELECTRICAL WORK SHALL COMPLY WITH THE CURRENT NFPA, NEC, NESC AND LOCAL CODES INCLUDING D - DIMMER CONTROL CEILINGS,', EXPOSED ELSEWHERE UNLESS OTHERWISE NOTED OWNERS STANDARDS AND REQUIREMENTS. OS - OCCUPANCY SENSOR ° 4. CONTRACTOR SHALL PLAN AND COORDINATE ELECTRICAL CONSTRUCTION WITH ALL CRAFT/TRADE TO ACHIEVE AN M - MOTOR RATED SWITCH CONCEALED CONDUIT IN FLOOR SLAB, UNDERGROUND, ETC. PUSHBUTTON,N.O., MOMENTARY CONTACT EFFICIENT AND EFFECTIVE ELECTRICAL INSTALLATION. - - - - - - 0 5. LP -1 (P5 -20R SIMPLEX SIMPLEX RECEPTACLE. ,�, N.C., MOMENTARY CONTACT REPRESENTATIVE. DUPLEX RECEPTACLE. CONDUIT TURNED UP CONTROL POWER TRANSFORMER 600V RATED ELECTRICAL EQUIPMENT SHALL HAVE AN AMPERE INTERRUPTING CAPACITY (AIC) EQUAL TO OR QUADRAPLEX RECEPTACLE. E SITE ELECTRICAL GREATER THAN 65kA. f Pr CURRENT .TRANSFORMER V VOICE (PHONE) OUTLET. °� LIMIT SWITCH 0 DATA OUTLET. TEMPERATURE SWITCH 0 VOICE/DATA COMBINATION OUTLET. T SITE TELEPHONE 8. NEW ELECTRICAL EQUIPMENT SHALL FIT INTO EXISTING AVAILABLE SPACE. CONTRACTOR IS RESPONSIBLE TO WIRING DEVICE NOTES: IF SHOWN, Q FLOAT SWITCH PROVIDE EQUIPMENT WHICH MEETS THE SPACE REQUIREMENTS. UPPER -LEFT CHARACTERS DENOTE T EXISTING SITE TELEPHONE PANEL BOARD CIRCUIT FOR POWER PRESSURE SWITCH TRANSITIONS THROUGH FINISHED GRADE AND CONCRETE SHALL BE PVC -COATED OR PVC -COATED AL CONDUIT OR OUTLETS. IF SHOWN, LOWER -RIGHT OHE OVERHEAD ELECTRICAL UTILITY AL CONDUIT PREPARED WITH A RUBBER -BASED PRIMER COATING FOLLOWED BY WITH TWO SPIRAL, HALF -LAPPED CHARACTERS DENOTE NEMA PLUG LAYERS OF 10 -MIL POLYVINYL CHLORIDE BASED CORROSION PROTECTION TAPE EXTENDING 12 -INCHES ABOVE AND AND/OR RECEPTACLE CONFIGURATION. FLOW SWITCH BELOW TRANSITION. POWER MONITOR OHT OVERHEAD TELEPHONE UTILITY PM PILOT LIGHT - LETTER INDICATES COLOR EXPOSED CONDUIT SHALL BE AL CONDUIT, RGS, IMC AND EMT IS NOT ACCEPTABLE. O R -RED, G -GREEN, W -WHITE, A -AMBER, ETC. OAMMETER A AS AMMETER SWITCH 1xr MOTOR OVERLOAD RELAY' HEATERS OVOLTMETER SOLENOID VS VOLTMETER SWITCH G SITE GROUND FS FLOAT/FLOW SWITCH a�\� MOTOR SPACE HEATER LS LIMIT SWITCH c - EXISTING SITE GROUND PS PRESSURE SWITCH CONTROL RELAY CABLE -TRAY, BUS -DUCT, WIRE -WAY, TRENCH/FLOOR DUCT, RACEWAY, CONDUIT, ETC., THESE SHALL NOT BE THERMOSTAT O M 0/C MOTOR OPERATED VALVE: JB JUNCTION BOX, SIZE PER NEC DENOTES FUSE SIZE (NF=NON-FUSED). BOTTOM NUMBER DENOTES FRAME SIZE. RIGHT NUMBER DENOTES NEMA M - MODULATING 0/C OPEN/CLOSE INSTALLATION. QUANTITY AND SIZING OF CONDUCTORS, CABLING, WIRING AND RESPECTIVE RACEWAYS DEPICTED ON THE CONTRACT ENCLOSURE RATING. - DRAWINGS ARE BASED UPON SELECTED STANDARD ELECTRICAL COMPONENTS OR EQUIPMENT WITH DIRECT ROUTED ELECTRICAL EQUIPMENT CONNECTION O S .SOLENOID VALVE CONDUCTOR AND RACEWAY GROUPINGS IN COMPLIANCE WITH APPLICABLE CODES, STANDARDS AND SPECIFICATIONS PULL OR JUNCTION BOX ENCLOSED CIRCUIT BREAKER: TOP NUMBER DENOTES TRIP. WITHOUT ADDITIONAL COST TO OWNER. SIZE PER NEC REQUIREMENTS BOTTOM NUMBER DENOTES FRAME SIZE. RIGHT NUMBER DISCONNECT SWITCH °131 / LOAD BREAK RACEWAY ROUTINGS SHALL BE ORGANIZED AND GROUPED IN A PRACTICAL MANNER TO MINIMIZE CROSS -OVERS CB 3R d AND SADDLES. RACEWAY INSTALLATIONS SHALL BE ARRANGED TO ENTER EQUIPMENT FOR DIRECT CONDUCTOR °) CIRCUIT BREAKER IP CLASS 1 /DIVISION 1/11 15. RACEWAYS SHALL BE INSTALLED CONCEALED UNLESS OTHERWISE NOTED OR SHOWN. THESE SHALL RUN PARALLEL CONDUIT SEAL -OFF FITTING COMBINATION MAGNETIC MOTOR STARTER OR MOTOR o CONTROL STATION ® FUSE 0 11;:71 OF 3R NUMBER DENOTES NEMA STARTER SIZE. TOP NUMBER DENOTES FUSE SIZE OR MCP. BOTTOM NUMBER DENOTES 16. ° p Qi GROUND ROD o� STOP -START STATION 17. ° p E110 DUCTBANK CALLOUT o� O LOCK -OUT -STOP SWITCH VOLTAGE NON -REVERSING MOTOR STARTER. LEFT INDICATED ON THE CONTRACT DRAWINGS. 042000 CONDUIT OR CABLE NUMBER ❑ LOCATED AT FIELD DEVICE 18. RACEWAY AND WIRING FOR LIGHTING, RECEPTACLES AND BRANCH CIRCUITS ARE NOT TYPICALLY SHOWN ON THE LOCATED AT MAIN CONTROL PANEL REDUCED VOLTAGE SOLID-STATE MOTOR STARTER. CONTRACT DRAWINGS BUT SHALL BE PROVIDED AS REQUIRED UNDER CONTRACT. O LOCATED AT LOCAL CONTROL PANEL 19. SPARE CONDUITS SHALL BE CAPPED OR PLUGGED WITH A PVC FITTING AND INCLUDE 200# TEST POLYPROPYLENE O MOUNTED ON DOOR PULL STRING. [VFD] VARIABLE FREQUENCY MOTOR CONTROLLER. 20. 00 INDUSTRIAL BATTERY SET ° ° W/MOUNTING RACK NOTES: 21. ° ° ALL SYMBOLS MAY NOT BE UTILIZED FOR THIS PROJECT. ° ° JUNCTIONS SHALL BE MADE BELOW GRADE WITHOUT APPROVAL OF ENGINEER. ADDITIONAL SYMBOLS NOT SHOWN ON THIS DRAWING MAY 22. CONTRACTOR SHALL PROVIDE ALL NECESSARY COMPONENTS REQUIRED FOR MAKING FINAL CONNECTIONS FOR ALL EQUIPMENT INSTALLED OR MODIFIED UNDER CONTRACT. BE SHOWN ELSEWHERE ON THE ELECTRICAL DRAWINGS. TYPICAL DEVICE MOUNTING HEIGHTS ANSI/IEEE DEVICE NUMBERS GENERAL NOTE: 27 UNDER VOLTAGE 59 OVER VOLTAGE DIMENSIONS ARE TO DEVICE TOP UNLESS NOTED OTHERWISE. INSTALLED WITH ASSOCIATED HARDWARE AND FASTENERS FOR CONDUIT AND EQUIPMENT SUPPORTS. RECEPTACLES (INTERIOR PROCESS AREAS) - 16" AFF 38 BEARING PROTECTION 74 ALARM RELAY RECEPTACLES (EXTERIOR PROCESS AREAS) - 48" AFF 46 PHASE UNBALANCE 81 FREQUENCY LIGHT SWITCHES 48" AFF CONTRACTOR SHALL PROVIDE ALL SUPPORTS AND FASTENING HARDWARE FOR SWITCHBOARDS, PANELBOARDS, M 1 ^ PHONE OUTLETS 16" AFF 48 INCOMPLETE SEQUENCE 86 LOCK OUT PHONE OUTLETS (WALL MOUNT) 64" AFF 49 OVER TEMPERATURE ' 87 DIFFERENTIAL DATA OUTLETS 16" AFF MOUNTED EQUIPMENT SPANNING DISTANCES 48" AND GREATER IN LENGTH OR 36" AND GREATER IN DEPTH. O EXIT LIGHTS (WALL MOUNT) 16" ABOVE DOOR 51 TIMED OVERCURRENT' EMERGENCY LIGHTS (WALL MOUNT) 96" AFF 1® TIMED GROUND FAULT NOTES: � v ' REV: v & CMED �4 2 3 NORTH FRONT ST WILMINGTON, NORTH CAROLINA 28401 _Cape Fear TELE. (910) 343-1048 Public UtilityAuthority FAX: (910) 251-8282 y LICENSE: F-1222 Stewardship. Sustainability. Service. LIGHTING SYMBOLS LIGHT FIXTURES (VARIOUS TYPES) - UPPERCASE Al a CHARACTERS "Al" DENOTE FIXTURE TYPE, REFER TO LP -1 LIGHTING SCHEDULE OR NOTES. NUMBER "LP -1" DENOTE LIGHTING PANEL AND/OR CIRCUIT NUMBER. LOWERCASE ® 3 4 LETTER "a" DENOTES CONTROL SWITCH. DUAL SWITCHING O INDICATED BY PAIRS OF LOWERCASE LETTERS. "NL" 0 DENOTES NIGHT LIGHT, CIRCUIT AHEAD OF CONTROL SWITCHES. EMERGENCY LIGHT - BATTERY EQUIPPED U EMERGENCY LIGHT, CIRCUIT AHEAD OF CONTROL SWITCHES. ADDITIONAL FIXTURE HEADS! MAY BE SHOWN CONNECTED TO UNIT. IF SHOWN, UPPERCASE LETTER DENOTES FIXTURE TYPE, REFER TO LIGHTING SCHEDULE OR NOTES. NUMBER DENOTES LIGHTING PANEL CIRCUIT. PTION I DATE: ELECTRICAL GENERAL NOTES, SYMBOLS,] LEGENDS AND ABBREVIATIONS PUBLIC UTILITY AUTHORITY SOUTHSIDE WWTP UV DISINFECTION SYSTEM CAPE FEAR PUBLIC UTILITY AUTHORITY 235 GOVERNMENT CENTER DRIVE WILMINGTON, NC 28403 OFFICE: (910)332-6560 DATE: JUN 2018 SCALE: N/A DRAWN BY: JAG CHECKED BY - AWB PROJECT NO. 07123-0002 SHEET NO: E1 GENERAL ELECTRICAL SYMBOLS GENERAL ELECTRICAL NOTES CONDUIT' HOMERUN TO EQUIPMENT SHOWN. LINE TYPE 1. REFERENCE ALL SPECIFICATIONS AND CONTRACT DRAWINGS FOR ADDITIONAL REQUIREMENTS AND CONTRACT DESIGNATES CONCEALED, EXPOSED, ETC. NUMBERS/TEXT RESPONSIBILITIES PRIOR TO COMMENCING WORK. DESIGNATE HOMERUN EQUIPMENT (I.E. PANEL BOARD 2. THE GENERAL NOTES STATED ON THIS DRAWING ARE APPLICABLE TO ALL ELECTRICAL DRAWINGS AND WORK UNDER LP -3 CIRCUIT NUMBER). CONTRACT UNLESS NOTED OTHERWISE. GENERAL! CONDUIT RUN CONCEALED IN FURRED WALLS AND 3. ALL ELECTRICAL WORK SHALL COMPLY WITH THE CURRENT NFPA, NEC, NESC AND LOCAL CODES INCLUDING CEILINGS,', EXPOSED ELSEWHERE UNLESS OTHERWISE NOTED OWNERS STANDARDS AND REQUIREMENTS. OR SPECIFIED. 4. CONTRACTOR SHALL PLAN AND COORDINATE ELECTRICAL CONSTRUCTION WITH ALL CRAFT/TRADE TO ACHIEVE AN - - - - - - CONCEALED CONDUIT IN FLOOR SLAB, UNDERGROUND, ETC. EFFICIENT AND EFFECTIVE ELECTRICAL INSTALLATION. - - - - - - EXISTING CABLE OR CONDUIT 5. THE SCHEDULING AND DURATION OF ANY PROCESS OR FACILITY SHUTDOWN TO REMOVE AND/OR INSTALL EQUIPMENT SHALL BE COORDINATED IN ADVANCE WITH FACILITY MANAGEMENT, ENGINEER, OWNER OR OWNER CONDUIT TURNED DOWN REPRESENTATIVE. CONDUIT TURNED UP 6. 600V RATED ELECTRICAL EQUIPMENT SHALL HAVE AN AMPERE INTERRUPTING CAPACITY (AIC) EQUAL TO OR E SITE ELECTRICAL GREATER THAN 65kA. 7. ELECTRICAL EQUIPMENT SHALL BE ARRANGED AND INSTALLED TO COMPLY WITH ALL CODE -REQUIRED, — E EXISTING SITE ELECTRICAL MANUFACTURER -RECOMMENDED AND HEAT -DISSIPATION CLEARANCES. FINAL INSTALLATIONS SHALL COMPLY WITH NEC ARTICLE 110 FOR ALL CLEARANCE REQUIREMENTS. T SITE TELEPHONE 8. NEW ELECTRICAL EQUIPMENT SHALL FIT INTO EXISTING AVAILABLE SPACE. CONTRACTOR IS RESPONSIBLE TO PROVIDE EQUIPMENT WHICH MEETS THE SPACE REQUIREMENTS. T EXISTING SITE TELEPHONE 9. TRANSITIONS THROUGH FINISHED GRADE AND CONCRETE SHALL BE PVC -COATED OR PVC -COATED AL CONDUIT OR OHE OVERHEAD ELECTRICAL UTILITY AL CONDUIT PREPARED WITH A RUBBER -BASED PRIMER COATING FOLLOWED BY WITH TWO SPIRAL, HALF -LAPPED LAYERS OF 10 -MIL POLYVINYL CHLORIDE BASED CORROSION PROTECTION TAPE EXTENDING 12 -INCHES ABOVE AND BELOW TRANSITION. OHT OVERHEAD TELEPHONE UTILITY 10. EXPOSED CONDUIT SHALL BE AL CONDUIT, RGS, IMC AND EMT IS NOT ACCEPTABLE. LIGE UNDERGROUND ELECTRICAL UTILITY 11. ELECTRICAL DRAWINGS DEPICT MAJOR DUCTBANK, CABLE -TRAY, BUS -DUCT, WIRE -WAY, TRENCH/FLOOR DUCTS, RACEWAY, CONDUIT, ETC., TO INCLUDE CABLE, CONDUCTOR AND WIRING IN SCHEMATIC AND/OR DIAGRAMMATIC UGT UNDERGROUND TELEPHONE UTILITY FORMATS. THE CONTRACTOR SHALL REFERENCE ALL EQUIPMENT SPECIFICATIONS AND MANUFACTURER INSTRUCTIONS FOR ADDITIONAL INSTALLATION REQUIREMENTS. G SITE GROUND 12. RACEWAY INSTALLATION AND/OR ARRANGEMENT LAYOUTS ARE NOT TYPICALLY SHOWN ON THE CONTRACT c - EXISTING SITE GROUND DRAWINGS. CONTRACTOR SHALL DEVELOP LOGICAL GROUPINGS, ROUTING AND MARSHALLING OF DUCTBANK, CABLE -TRAY, BUS -DUCT, WIRE -WAY, TRENCH/FLOOR DUCT, RACEWAY, CONDUIT, ETC., THESE SHALL NOT BE ROUTED THROUGH OR INTERFERE WITH ANY STRUCTURAL ELEMENTS. CONTRACTOR SHALL SUBMIT THESE RACEWAY OR FUSED DISCONNECT SWITCH: TOP NUMBER INSTALLATION AND/OR ARRANGEMENT LAYOUTS PER THE SPECIFICATIONS FOR REVIEW BY ENGINEER PRIOR TO nNON-FUSED 3R DENOTES FUSE SIZE (NF=NON-FUSED). BOTTOM NUMBER DENOTES FRAME SIZE. RIGHT NUMBER DENOTES NEMA 13. INSTALLATION. QUANTITY AND SIZING OF CONDUCTORS, CABLING, WIRING AND RESPECTIVE RACEWAYS DEPICTED ON THE CONTRACT ENCLOSURE RATING. DRAWINGS ARE BASED UPON SELECTED STANDARD ELECTRICAL COMPONENTS OR EQUIPMENT WITH DIRECT ROUTED CONNECTIONS. CONTRACTOR MAY SUBMIT FOR REVIEW BY ENGINEER AND PRIOR TO INSTALLATION, LOGICAL CONDUCTOR AND RACEWAY GROUPINGS IN COMPLIANCE WITH APPLICABLE CODES, STANDARDS AND SPECIFICATIONS nA ENCLOSED CIRCUIT BREAKER: TOP NUMBER DENOTES TRIP. WITHOUT ADDITIONAL COST TO OWNER. 2 BOTTOM NUMBER DENOTES FRAME SIZE. RIGHT NUMBER DENOTES NEMA ENCLOSURE RATING. 14. RACEWAY ROUTINGS SHALL BE ORGANIZED AND GROUPED IN A PRACTICAL MANNER TO MINIMIZE CROSS -OVERS CB 3R AND SADDLES. RACEWAY INSTALLATIONS SHALL BE ARRANGED TO ENTER EQUIPMENT FOR DIRECT CONDUCTOR TERMINATIONS 15. RACEWAYS SHALL BE INSTALLED CONCEALED UNLESS OTHERWISE NOTED OR SHOWN. THESE SHALL RUN PARALLEL COMBINATION MAGNETIC MOTOR STARTER OR MOTOR TO LANDSCAPE AND STRUCTURAL FEATURES WHILE THE BENDS AND TURNS SHALL BE MADE BY MEANS OF LARGE CIRCUIT PROTECTOR WITH DISCONNECT SWITCH: LEFT RADII FITTINGS. 11;:71 OF 3R NUMBER DENOTES NEMA STARTER SIZE. TOP NUMBER DENOTES FUSE SIZE OR MCP. BOTTOM NUMBER DENOTES 16. PROVIDE FLEXIBLE RACEWAY CONNECTIONS TO ALL EQUIPMENT SUBJECT TO MOVEMENT AND/OR VIBRATION. / FRAME SIZE. RIGHT NUMBER DENOTES NEMA ENCLOSURE. CONTRACTOR SHALL MAKE RACEWAY CONNECTIONS COMPLETE AND IN ACCORDANCE WITH THE SPECIFICATIONS. 3 17. CONTRACTOR SHALL PROVIDE ALL REQUIRED PULL BOXES, TERMINAL BOXES AND JUNCTION BOXES FOR INSTALLATION OF THE WIRING IN ACCORDANCE WITH THE CONTRACT SPECIFICATIONS THOUGH BOXES MAY NOT BE EdFULL VOLTAGE NON -REVERSING MOTOR STARTER. LEFT INDICATED ON THE CONTRACT DRAWINGS. NUMBER DENOTES NEMA STARTER SIZE. 18. RACEWAY AND WIRING FOR LIGHTING, RECEPTACLES AND BRANCH CIRCUITS ARE NOT TYPICALLY SHOWN ON THE VS REDUCED VOLTAGE SOLID-STATE MOTOR STARTER. CONTRACT DRAWINGS BUT SHALL BE PROVIDED AS REQUIRED UNDER CONTRACT. 19. SPARE CONDUITS SHALL BE CAPPED OR PLUGGED WITH A PVC FITTING AND INCLUDE 200# TEST POLYPROPYLENE PULL STRING. [VFD] VARIABLE FREQUENCY MOTOR CONTROLLER. 20. CONTRACTOR SHALL PROVIDE A CIRCUIT IDENTIFICATION LABEL AT EACH END OF EACH POWER, BRANCH, CONTROL AND INSTRUMENTATION CIRCUIT CABLE ASSEMBLY, CONDUCTOR OR WIRE. 52 ANSI/IEEE TYPE -52 AC POWER CIRCUIT BREAKER 21. NO SPLICES TO POWER CONDUCTORS AND/OR CABLING SHALL BE MADE WITHOUT ENGINEER APPROVAL. NO JUNCTIONS SHALL BE MADE BELOW GRADE WITHOUT APPROVAL OF ENGINEER. VACUUM STARTER 22. CONTRACTOR SHALL PROVIDE ALL NECESSARY COMPONENTS REQUIRED FOR MAKING FINAL CONNECTIONS FOR ALL EQUIPMENT INSTALLED OR MODIFIED UNDER CONTRACT. HP MOTOR (HP=RATED HORSEPOWER) 23. STRUT -CHANNEL SHALL NOT BE BENT, DRILLED, CUT OR OTHERWISE MODIFIED TO PRODUCE FITTINGS, BRACES OR BRACKETS FOR CONDUIT AND EQUIPMENT SUPPORTS. 24. MANUFACTURED STRUT -CHANNEL BRACES, BRACKETS, FITTINGS OR POST BASES SHALL BE PROVIDED AND M INSTALLED WITH ASSOCIATED HARDWARE AND FASTENERS FOR CONDUIT AND EQUIPMENT SUPPORTS. AC MOTOR (THREE PHASE) 3 N 25. CONTRACTOR SHALL PROVIDE ALL SUPPORTS AND FASTENING HARDWARE FOR SWITCHBOARDS, PANELBOARDS, M 1 ^ AC MOTOR'; (SINGLE PHASE) 26. TRANSFORMERS, CONTROL PANELS, ETC., AS REQUIRED IN THE SPECIFICATIONS. CONTRACTOR SHALL PROVIDE AND INSTALL CONCRETE EMBEDDED LEVELING CHANNEL SUPPORTS FOR FLOOR MOUNTED EQUIPMENT SPANNING DISTANCES 48" AND GREATER IN LENGTH OR 36" AND GREATER IN DEPTH. O DC MOTOR 27. STRUCTURAL MEMBERS SHALL NOT BE DRILLED, CUT, WELDED TO, OR OTHERWISE MODIFIED WITHOUT PRIOR APPROVAL OF THE ENGINEER OF RECORD. NOTES: ALL SYMBOLS MAY NOT BE UTILIZED FOR THIS PROJECT. ADDITIONAL SYMBOLS NOT SHOWN ON THIS DRAWING MAY BE SHOWN ELSEWHERE ON THE ELECTRICAL DRAWINGS. IF REQUIRED, IEC RATINGS WILL INCLUDE THE "IEC" AND "IP" PREFIX. LIGHTING SYMBOLS LIGHT FIXTURES (VARIOUS TYPES) - UPPERCASE Al a CHARACTERS "Al" DENOTE FIXTURE TYPE, REFER TO LP -1 LIGHTING SCHEDULE OR NOTES. NUMBER "LP -1" DENOTE LIGHTING PANEL AND/OR CIRCUIT NUMBER. LOWERCASE ® 3 4 LETTER "a" DENOTES CONTROL SWITCH. DUAL SWITCHING O INDICATED BY PAIRS OF LOWERCASE LETTERS. "NL" 0 DENOTES NIGHT LIGHT, CIRCUIT AHEAD OF CONTROL SWITCHES. EMERGENCY LIGHT - BATTERY EQUIPPED U EMERGENCY LIGHT, CIRCUIT AHEAD OF CONTROL SWITCHES. ADDITIONAL FIXTURE HEADS! MAY BE SHOWN CONNECTED TO UNIT. IF SHOWN, UPPERCASE LETTER DENOTES FIXTURE TYPE, REFER TO LIGHTING SCHEDULE OR NOTES. NUMBER DENOTES LIGHTING PANEL CIRCUIT. PTION I DATE: ELECTRICAL GENERAL NOTES, SYMBOLS,] LEGENDS AND ABBREVIATIONS PUBLIC UTILITY AUTHORITY SOUTHSIDE WWTP UV DISINFECTION SYSTEM CAPE FEAR PUBLIC UTILITY AUTHORITY 235 GOVERNMENT CENTER DRIVE WILMINGTON, NC 28403 OFFICE: (910)332-6560 DATE: JUN 2018 SCALE: N/A DRAWN BY: JAG CHECKED BY - AWB PROJECT NO. 07123-0002 SHEET NO: E1 EXISTING 1A PLANT DISTRIBUTION SWITCHBOARD 1600A 480V JO j ...... _...._ __.. -- --------- — - -- 1600/3 N E ° 800/3 60/3 500/3 00/3 600/3 t E I i I � I o / 1- 1 in W Z O Z U Z Z 4 O Z o o !� cj Wz W o� � o O W o0 3A� Q 2�mcpo Q Q:) N N Z O W j N U m i � W U O O k W v O O � O EXISTING SINGLE -LINE DEMOLITION PLAN SCALE: NONE EXISTING 1A PLANT DISTRIBUTION SWITCHBOARD 160OA 4 8 0 V 3 0 --- - - -- - - - - -- ---- - - --- _ ---------- _ 1600/3 yN E \ 800/3 t \ 60/3 0/ 800AT 600/3 4 ° 3P ELTU I j I j I - -- - - -- - - --- - --- --- - -- ---- I - — CD I ; c;.r _ _ 2A j 1 I U j U O j i p p 1--- j L � p ✓� I j Z------ Qt� Uj ZC) Z- Q �Vo WZ �u pa W Qc+ W Qtt of W �d oo mo mo Qo0 Q o O J N W N W O m W ;O Z N Q N m0 ~ co Q Z Zm p O Q O Z U O �� a EL V O Z u00 C� O o 0 N O O N EXISTING SINGLE -LINE WITH NEW "MODIFICATIONS N SCALE: NONE 0 Li 0 REV: g$4N14UM & CMED M 3 243 NORTH FRONT ST NmCea Fear WILMINGTON, NORTH CAROLINA 28401 p TELE: (910) 343-1048 Public Utility Authority i FAX: (910) 251-8282 y y 0 o LICENSE: F-1222 Stewardship. Sustainability. Service. M 0 DATE: EXISTING SINGLE -LINE DIAGRAM JUN 2018 SCALE: DEMOLITION PLAN AND MODIFCATIONS N/A DRAWN BY: JAG CAPE FEAR CHECKED BY: PUBLIC UTILITY AUTHORITY AWB `fyf!!,lrrf SOUTHSI DE WWTP PROJECT N0. DESCRIPTION DATE: 07123-0002 UV DISINFECTION SYSTEM •¢ SE " 041530 rrr A Gi��-�',,� ll CAPE FEAR PUBLIC UTILITY AUTHORITY 235 GOVERNMENT CENTER DRIVE WILMINGTON, NC 28403 OFFICE: (910)332-6560 J SHEET NO: E 2 in NEW PANELBOARD 'P3' 480V 3� 3W 800A BUSS 22kAIC RATING NEMA -12 ENCLOSURE 3POATMTU ) 3POATMTU ) 3P0 ATMTU > 3P ATMTU ) 3P ATMTU ) 2P TMTU ST 25T 125T 125T 80AT PD 160AT 3P TMTU zT z� mz mz U O U O U O UO U Zp c.� ov ov � v Q 1A 1B Q Ljj1A 1B Q L�j1A 1B U Q LJ 1A 1B Q s z z 4X/SS 4X/ss z z v Q I Q v Q v Q L, -j Q M k Q x Q x Q k Q 1C x Q ° o j6-0--6-0 I ° ° tiQ W ZQ �Q z� wZ o wZ C o Zm Z Zm Z �Q W v W W N W Q Z Q Z W m O Z Z CJQ UQ Cn m O Z Z W W W W p p H W z m P F - Q 0 O O O N m m m m m I m 1 Q Q O U N Z z cr ofa 0 0 a a o � w Li z m o 0 LL W 50AT 30AT 30AT 30AT 30AT Z =j 2P TMTU 3P TMTU 3P TMTU 3P TMTU 3P TMTU z t? ox U w a d --- _- c o c� JB NEMA-4X/SS U NNFF . 0o Q 1 A 1 B o 0 3CA� 4X/SS M Z 0 O M M J NF 0 o M 4X/SS 4X/SS o O O ik -. O O O r. .-. ° ° M 1.OHP M 1.OHP >^ o o 1 C 3- FLA 2.1 3 .., FLA 2.1 ^ I..L '.. p zop�> z� ob 3No 3� 3�N 01 F= T_ �� ZZp0 ZZ00 ZZZ zZ O = Q 1 p ,� CV Z U Nam W J Z I z I Uz Uz U) V) opo a>o �o a �a D 00 Z Z_ < N U W �, � (n N N CL Z p0 Z Q Q U� o w } } wW a_ a_ _ _ zw o p af=W Ua 0 o 3 w Z 0 NEW SINGLE -LINE DIAGRAM SCALE: NONE v &CMED 'V 243 NORTH FRONT ST WILMINGTON, NORTH CAROLINA 28401 UNicape Fear TELE: (910) 343-1048 FAX: (s1o) 251-8282 Public Utility Authority LICENSE: F-1222 Stewardship. Sustainability. Service. m U O EAF ov ZW Q� REV: � � Fd z GENERAL NOTES: LIJ 1. REFERENCE SHEET E1 FOR ELECTRICAL NOTES, ABBREVIATIONS AND SYMBOLS. 0 ti Li r2. EXPOSED CONDUIT SHALL BE AL CONDUIT UNLESS OTHERWISE NOTED ON PLANS; RGS, IMC AND EMT IS NOT ACCEPTABLE. 1A Ln 3. RACEWAY TRANSITIONS THROUGH CONCRETE AND FINISHED GRADE SHALL BE w F PVC -COATED AL CONDUIT. 60AT 50AT 50AT Z o 4. ALL FEEDER CONDUCTORS AND CABLING FOR POWER CIRCUITS RATED 100A AND 3P TMTU ) 3P TMTU ) 3P TMTUz GREATER SHALL BE STRANDED COPPER 600V XHHW-2. O U- 0 Uj 5. ALL CONDUCTORS AND WIRES FOR CONTROL CIRCUITS SHALL BE STRANDED COPPER J 300V THHN/THWN. m Li 3 0 3 N KEYNOTES: NF � � Fd z U '- 0 ti 1A INTERCEPT EXISTING RACEWAY AND CABLING AND RE -TERMINATE AS REQUIRED Zs O p-LJNF 3 N NF 1B EXTEND EXISTING RACEWAY WITH NEW OF SAME MATERIAL AND SIZE IF 1A 1B Q 1A 1B WO Z EXISTING RACEWAY CANNOT BE RE -CONNECTED TO EXISTING EQUIPMENT Q o O 00 4X/SS 4X/SS ENCLOSURES Q M 1C REPLACE IN ITS ENTIRETY EXISTING CABLING, CONDUCTORS AND WIRING WITH NEW OF SAME QUANTITY, INSULATION, CONDUCTOR MATERIAL AND SIZE IF W EXISTING CABLING, CONDUCTORS AND WIRING CANNOT BE RE -TERMINATED TO EXISTING EQUIPMENT LUGS, TERMINALS, ETC. C O 0 v 0 ZNp wW�WWN �Z ZZZ ZZ ° Z W Q Z Q Z U Q U Q j p px N _m I m 1 Q � � � U Z IL a 4 25'a- 0 0 120AT j 3P TMTU a a 20AT 3P TMTU ms �o 1A 1B Q 1A 1B a z LQ Z v w DATE: NEW SINGLE -LINE DIAGRAM JUN 2018 SCALE: N/A DRAWN BY: JAG CAPE FEAR CHECKED BY DESCRIPTION DATE: tl'�i 7/�Jlf(f! ,11 CAP? !� SE 041530 0 ..GINS h !(rtilllt�+``t PUBLIC UTILITY AUTHORITY AWB SO UTH S I D E WWTP PROJECT NO.: UV DISINFECTION SYSTEM . CAPE FEAR PUBLIC UTILITY AUTHORITY 235 GOVERNMENT CENTER DRIVE WILMINGTON, NC 28403 OFFICE: (910)332-6560 07123-0002 SHEET NO: E3 0 ti v O M 1C 3 N C� N WO Z O DATE: NEW SINGLE -LINE DIAGRAM JUN 2018 SCALE: N/A DRAWN BY: JAG CAPE FEAR CHECKED BY DESCRIPTION DATE: tl'�i 7/�Jlf(f! ,11 CAP? !� SE 041530 0 ..GINS h !(rtilllt�+``t PUBLIC UTILITY AUTHORITY AWB SO UTH S I D E WWTP PROJECT NO.: UV DISINFECTION SYSTEM . CAPE FEAR PUBLIC UTILITY AUTHORITY 235 GOVERNMENT CENTER DRIVE WILMINGTON, NC 28403 OFFICE: (910)332-6560 07123-0002 SHEET NO: E3 U r i C9 M CL z 0 Q Om m z W O aF- CL (if 3Q W z c� 00E- N X W 11.1 UV POWER DISTRIBUTION CENTER TRAIN No.1 'PDC -1A -1C' I oU U cno Uj LLJ oU Z2 U 22 C) \ � O d' It J _Z O st M N d za.. ww �a O O IN, (3000 Om CK 0 Doo W U- 3 N o:.. _ Nu U N U M 2 W N 4 v00 Q a ZS ZS JE JE JE 1200 1210 1000 1010 1020 a� Qo —O mo 0-0 N acn '-N mV) —N vV) —N ao —0 mo ter- Uo —N ao —0 mo �.- W (n Y 0 Y Y O YCn YN YN x 0 Y 0 y 0 - y N I Y 0 W W 0 mj O qm> O m> O m m� my mw Q mw Q Qw m Q m m N Qcn m N az ?j Q W Z O J Zm O J zm O Zm Om z� Om Z� Om zm ON Z E ON07' z E ON z () U z� U zl- zo m zW .zW ZW zv z� zN z� z� E z� z� zs O\ ~z ;;-r V) �Q atn �Q QN �Q :R (n �a Qcn �a acn �� `a3 W E ¢3 Q3 QV) Qcn >a >a >a >m >2 >m > >>- > >� >m �� a� DM J J Z)Q J D nX �X af -j -i J > > > Z z Z a' of z z z > > > U U N \ � W It N M N s 0-0 r N Y N Z aN m N LEVEL SENSOR CONTROL BOX TRAIN No.1 'LC -1000' 1A I U U I\ M C9 � N F- N W � CO N � U N - u r to b 1000 M W 0 U W U W Qf- zo cn�� z 0 U J Z N Z O w ad Z> �O UO W� z -1 0 LLj 00 LLI0 z Q 1� 0 f� 0 Z z z z oz oz > 0 O �U :2U En o 0 f-- POWER AND CONTROL RISER DIAGRAM SCALE: NONE vC.R�ED 243 NORTH FRONT ST C WILMINGTON, NORTH CAROLINA 28401 Mocape' Fear TELE: (910) 343-1048 FAX: (910) 251-8282 Public Utility Authority LICENSE: F-1222 Stewardship. Sustainability. Service. UV POWER DISTRIBUTION CENTER TRAIN No.1 1A GENERAL NOTES: 'PDC -1D' 1. REFERENCE SHEET E1 FOR ELECTRICAL NOTES, ABBREVIATIONS AND SYMBOLS. 2. EXPOSED CONDUIT SHALL BE AL CONDUIT UNLESS OTHERWISE NOTED ON PLANS; RGS, IMC AND EMT IS NOT ACCEPTABLE. 3. RACEWAY TRANSITIONS THROUGH CONCRETE AND FINISHED GRADE SHALL BE PVC -COATED AL CONDUIT. v o U cn o 00 U U v v 4. ALL FEEDER CONDUCTORS AND CABLING FOR POWER CIRCUITS RATED 100A AND o m z o ^ GREATER SHALL BE STRANDED COPPER 600V XHHW-2. ►� r) Q M o o r� 5. ALL CONDUCTORS AND WIRES FOR CONTROL CIRCUITS SHALL BE STRANDED COPPER 00 Z 0 Z j^^ N 300V THHN/THWN. Oa pLi O Oa l~i Ui 742 N o m N KEYNOTES: ►7 U= mO U= tp (O M U 3(n.. 3 ( N M N 1A CONTRACTOR SHALL COORDINATE ALL REQUIREMENTS WITH EQUIPMENT _ U- V) _ � � SUPPLIER TO ENSURE A COMPLETE AND FULL FUNCTION INSTALLATION v Q JE ZS 1030 1230 .aww ''o , N � to M 0 W Y 0 YQ y O Y 04 a' J N Q I Q= Q am ,a,., m� m� m¢ mN m a_Z } _ jj0 30 o J om N ov z I- W z z m zg z Z QQ z0 zM zN z v z� 3aoma, av a< a3 aN W ~ z Q� zc� o =a >m ? _� z z N Q J U) x0 J > z W C7 > a z > 01 DATE: JUN 2018 SCALE: N/A J DRAWN BY. JAG CAPE FEAR CHECKED BY - REV: DESCRIPTION DATE: CAR 0 "SS SE SE 041530 - � •t z s�'� zot�;; 'f!!llktl iitll PUBLIC UTILITY AUTHORITY AWB SOUTHSIDE WWTP PROJECT NO. UV DISINFECTION SYSTEM CAPE FEAR PUBLIC UTILITY AUTHORITY 235 GOVERNMENT CENTER DRIVE WILMINGTON, NC 28403 OFFICE: (910)332-6560 07123-0002 SHEET NO: E4 UV POWER DISTRIBUTION CENTER TRAIN No.2 'PDC -2A -2C' U _ a H Li N N U N N LEVEL SENSOR CONTROL BOX TRAIN No.2 'LC -2000' 1A I cv U ri ri N N LL N U N u 2000 fr W O U W U W < ZN NI— NI— _j = Uj I w w W W ZO UJ Z� Z(= O 4 � N J W0 W � a I p W 0 R U� Uj zw op 00 Z. Z J W W Q O O O of o� > 0z 0z my 20 N (n > > O O POWER AND CONTROL RISER DIAGRAM SCALE: NONE v000p N11a4&CMED 243 NORTH FRONT ST WILMINGTON, NORTH CAROLINA 28401 NmCapeC ' 1�ear TELE: (910) 343-1048 PU%iIC UtilityAuthority LICENSE: F-1222 Stewardship. Sustainability. Service. 9 3N �� fir. f--- 3N - > - 'A GENERAL NOTES: 2 LL_ fn ------------ v ov wo CENTER TRAIN 0U rU 0 0 Q o z o \ m M Q m M M 1. REFERENCE SHEET E1 FOR ELECTRICAL NOTES, ABBREVIATIONS AND SYMBOLS. r- � U W � U n n 2. EXPOSED CONDUIT SHALL BE AL CONDUIT UNLESS OTHERWISE NOTED ON PLANS; Q cps Ona- wo o� RGS, IMC AND EMT IS NOT ACCEPTABLE. �k �W SW �OD ti W JE O m JE g2200> O= c� ZS < 0 2000 2010 2020 2210 2220 dZ 0 NO m 0 N— U _ a H Li N N U N N LEVEL SENSOR CONTROL BOX TRAIN No.2 'LC -2000' 1A I cv U ri ri N N LL N U N u 2000 fr W O U W U W < ZN NI— NI— _j = Uj I w w W W ZO UJ Z� Z(= O 4 � N J W0 W � a I p W 0 R U� Uj zw op 00 Z. Z J W W Q O O O of o� > 0z 0z my 20 N (n > > O O POWER AND CONTROL RISER DIAGRAM SCALE: NONE v000p N11a4&CMED 243 NORTH FRONT ST WILMINGTON, NORTH CAROLINA 28401 NmCapeC ' 1�ear TELE: (910) 343-1048 PU%iIC UtilityAuthority LICENSE: F-1222 Stewardship. Sustainability. Service. 9 3N fir. 3N N 'A GENERAL NOTES: 2 LL_ fn UV POWER DISTRIBUTION CENTER TRAIN No.2 rU x Q x 'PDC -2D' w 1. REFERENCE SHEET E1 FOR ELECTRICAL NOTES, ABBREVIATIONS AND SYMBOLS. U 2. EXPOSED CONDUIT SHALL BE AL CONDUIT UNLESS OTHERWISE NOTED ON PLANS; Q RGS, IMC AND EMT IS NOT ACCEPTABLE. JE JE JE g2200> ZS < > ZS < 3. RACEWAY TRANSITIONS THROUGH CONCRETE AND FINISHED GRADE SHALL BE 2000 2010 2020 2210 2220 dZ 0 NO m 0 N— 0-0 NN QV) C-4 Fn mV) C-4 Fn UN 04 U5 Q p NO m p N� U 0 NN Q 0 NO m O N� U p NN 0�_ �_� O ZN O ZN O ZN N ZQ to ZQ U) ZQ O ZN O zN O ZN N ZN N z N ZN U U �� 4. ALL FEEDER CONDUCTORS AND CABLING FOR POWER CIRCUITS RATED 100A AND Q> Q> '�> Q0 QU Qc� QW `�W QW QV) Qtn Qcn Q� O m W U in m 0 m m 0 =- m m m m Q m Q m Q m N m N m N mZ WO a Z ASO o '`� N} 0 N} pJ N pJ NJ pm N_j om NJ Om N^ ON N^ oN N^ ON N O= N= OU N O= z -- zo z U zm zm Zm zW zW zW z E z E z E Z� z� z� aa- of W 0 m �� Z W Q� Z W :z( V) z W QV Z to aQ z V) aQ Z (n QQ Z\ Q3 z\ Q3 Z\ 43 z� qN z� Qtn Z� Qcn z� z �Q �Q �Q 04 �a �a � E E f5 E z OF p0 z n >a Mm >a Om >a Og t~i >m �< >m OJ >2 �< >� �� >� �X �X >X f- V) M0 O Q Q J Q J o m in N V) O O a O v N > > > n � o a-00 a z z z 3 N cr 3 N N 0 N CONTRACTOR SHALL COORDINATE ALL REQUIREMENTS WITH EQUIPMENT _ U_ V _ M � •- 1A � U _ a H Li N N U N N LEVEL SENSOR CONTROL BOX TRAIN No.2 'LC -2000' 1A I cv U ri ri N N LL N U N u 2000 fr W O U W U W < ZN NI— NI— _j = Uj I w w W W ZO UJ Z� Z(= O 4 � N J W0 W � a I p W 0 R U� Uj zw op 00 Z. Z J W W Q O O O of o� > 0z 0z my 20 N (n > > O O POWER AND CONTROL RISER DIAGRAM SCALE: NONE v000p N11a4&CMED 243 NORTH FRONT ST WILMINGTON, NORTH CAROLINA 28401 NmCapeC ' 1�ear TELE: (910) 343-1048 PU%iIC UtilityAuthority LICENSE: F-1222 Stewardship. Sustainability. Service. 9 el DATE: JUN 2018 SCALE: N/A J DRAWN BY: JAG CAPE FEAR CHECKED BY - REV: I DESCRIPTION I DATE: CARO",,"' ARO r,,'' SSt <fy9 SE _ 041530 . ys-.►�Ws�r �� div k (1 { �'� *'1.114. PUBLIC UTILITY AUTHORITY AWB SO UTH S I D E WWTP PROJECT NO. 07123-0002 UV DISINFECTION SYSTEM CAPE FEAR PUBLIC UTILITY AUTHORITY 235 GOVERNMENT CENTER DRIVE WILMINGTON, NC 28403 OFFICE: (910)332-6560 r SHEET NO: E5 'A GENERAL NOTES: UV POWER DISTRIBUTION CENTER TRAIN No.2 'PDC -2D' 1. REFERENCE SHEET E1 FOR ELECTRICAL NOTES, ABBREVIATIONS AND SYMBOLS. 2. EXPOSED CONDUIT SHALL BE AL CONDUIT UNLESS OTHERWISE NOTED ON PLANS; RGS, IMC AND EMT IS NOT ACCEPTABLE. 3. RACEWAY TRANSITIONS THROUGH CONCRETE AND FINISHED GRADE SHALL BE PVC -COATED AL CONDUIT. U 0 U cn 0 00 U U U U 4. ALL FEEDER CONDUCTORS AND CABLING FOR POWER CIRCUITS RATED 100A AND z z W W Z t: in in a =- GREATER SHALL BE STRANDED COPPER 600V XHHW-2. < o '`� co o M 5. ALL CONDUCTORS AND WIRES FOR CONTROL CIRCUITS SHALL BE STRANDED COPPER c� z U z U ►�-, � 0 a 300V THHN/THWN. Oa Off' 04 k p0 t~i t~i_ N M0 00 o m N KEYNOTES: o a-00 3 N cr 3 N N 0 N CONTRACTOR SHALL COORDINATE ALL REQUIREMENTS WITH EQUIPMENT _ U_ V _ M � •- 1A � SUPPLIER TO ENSURE A COMPLETE AND FULL FUNCTION INSTALLATION x Q x � w U Q a zS JE 2230 - 2030 Z N M NN N M N M _aU 0 N zN YQ zN zN a� �N a> aX < I aN om °°� °°} mQ m,,,, m Z N. N _I C'4 W W Z zm zm Z E Z Q Q Z m ZZ� Z v z s z �Q �a �� Wz z >a >� > >� HN O� J ; > ��' Z tr a z el DATE: JUN 2018 SCALE: N/A J DRAWN BY: JAG CAPE FEAR CHECKED BY - REV: I DESCRIPTION I DATE: CARO",,"' ARO r,,'' SSt <fy9 SE _ 041530 . ys-.►�Ws�r �� div k (1 { �'� *'1.114. PUBLIC UTILITY AUTHORITY AWB SO UTH S I D E WWTP PROJECT NO. 07123-0002 UV DISINFECTION SYSTEM CAPE FEAR PUBLIC UTILITY AUTHORITY 235 GOVERNMENT CENTER DRIVE WILMINGTON, NC 28403 OFFICE: (910)332-6560 r SHEET NO: E5 UV SYSTEM CONTROL CENTER 'SCC' U _ U U oU z U U U U M M _� N M O m D O m w p aZ mz Wp ►`� M M t7 M P') \~ Q Q ro I tj w m c� o O U Z> c� c� c� 0 N N N N � o� F -Z PVC -COATED AL CONDUIT. w¢ ¢ w¢ O n- 4k z4k N o N I 0 O I p O OF 0I �--f n f2 SPD E1 �t SPD V)p 5. ALL CONDUCTORS AND WIRES FOR CONTROL CIRCUITS SHALL BE STRANDED COPPER NU v \ AC/DC � AC/DC O o N I I 4k p V � LL N U N x 00 00 ( O ( O SUPPLIER TO ENSURE A COMPLETE AND FULL FUNCTION INSTALLATION x X r U U 1A Ln N N N M HYDRAULIC SYSTEM CENTER UV TRAIN No.2 N to 'HSC -1' 'HSC -2' U I I N o O U $wP $wP U O U FR (RT MOVF2OOO (1000 M 1.OHP 3N n,3,/,v 1.OHP m; 000 3000 o U U U U I U I U RE LE FLA 2.1 FLA 2.1 3000 3000 QW_'U�I-C9^ O`- �� Wim" ON H" Od W" I-� W F-�W I -N W I -NW ZZ W � I 0066 of I 30ZOp � I >O �0 a0 zQ� z�� z I z 1 -0 ¢Y N z(n0 ¢F- JWO ¢F- QO z Qo _ z W W W¢ W U O ¢z M O Y LLM r: 0 �1 D N 4 USW UOW UNW UOW ¢Ow mU ��- F -W I m W I m > I 0J % 1 OJ D_ I Q U m J_ � N F- (n J X_ J J 0_' - 0_' - oo(n o�(n ZU(n Z" (n (n w0 Ld it Ld w0 �wJ Uj w0 �O ¢m 00 ¢m pp pN �z zO (L (n Z0 \ Z0 O O 1=a� F O� 1=d� F p� SOW dL z zZQ�- d�- =ZE-- <�- ¢_ mZ ¢� mz Z) p Oz0 O" O Ozo \�U �� ¢ � I Ln¢� I of w0 0! w0 M 0 L m Z m N L� of m Z L� J� W � J Z O ��" 3 J d d Z 1- W Z �z �Q ° �- o_w� W m W W" LL. LL] w" ¢¢ or ¢¢ V) 0 v, 0 (nZC) (n¢0 ¢� z �\ >J z F- F_ Z O aw aw oZ� 0 oz� o�U Zzw o z =0 o z� o 3¢ 3¢ ¢ F- w w 1 F- O w O w z z � z z x�v Z JOv ZQ m 00 F O F 0 OU 0 OU 0 OU 0 OU w¢ m Z -� N N (n a d v CL .. a v o0 o 0 d X 6 X > > > > F- of z z > > z z 0 0 0 0 N POWER AND CONTROL RISER DIAGRAM SCALE: NONE vqQW&CMED 243 NORTH FRONT ST WILMINGTON, NORTH CAROLINA 28401 _Cape Fear TELE. (910) 343-1048 Public'Utilit Authority FAX: (910) 251-8282 y LICENSE: F-1222 Stewardship. Sustainability. Service. ,A GENERAL NOTES.- OTES:1. aZ M M _� o m M O m 2. EXPOSED CONDUIT SHALL BE AL CONDUIT UNLESS OTHERWISE NOTED ON PLANS; O m w p aZ mz Wp 30 RGS, IMC AND EMT IS NOT ACCEPTABLE. 30 Q Q ro I tj I a Cr om F -Z a o� F -Z PVC -COATED AL CONDUIT. w¢ w¢ J 0 N w J o N I 0 O I p O OF GREATER SHALL BE STRANDED COPPER 600V XHHW-2. OP F- V)p 5. ALL CONDUCTORS AND WIRES FOR CONTROL CIRCUITS SHALL BE STRANDED COPPER ¢ ZO: ¢ C9 I I 4k KEYNOTES: U N U N ( O ( O SUPPLIER TO ENSURE A COMPLETE AND FULL FUNCTION INSTALLATION 1A N N HYDRAULIC SYSTEM CENTER UV TRAIN No.1 M HYDRAULIC SYSTEM CENTER UV TRAIN No.2 'HSC -1' 'HSC -2' I I o O U U O U M 1.OHP 3N n,3,/,v 1.OHP m; RE LE FLA 2.1 FLA 2.1 3000 3000 QW_'U�I-C9^ O`- �� Wim" ON H" Od W" I-� W F-�W I -N W I -NW ZZ W � I 0066 of I 30ZOp � I >O �0 a0 zQ� z�� z I z 1 -0 ¢Y N z(n0 ¢F- JWO ¢F- QO z Qo _ z W W W¢ W U O ¢z M O Y LLM r: 0 �1 D N 4 USW UOW UNW UOW ¢Ow mU ��- F -W I m W I m > I 0J % 1 OJ D_ I Q U m J_ � N F- (n J X_ J J 0_' - 0_' - oo(n o�(n ZU(n Z" (n (n w0 Ld it Ld w0 �wJ Uj w0 �O ¢m 00 ¢m pp pN �z zO (L (n Z0 \ Z0 O O 1=a� F O� 1=d� F p� SOW dL z zZQ�- d�- =ZE-- <�- ¢_ mZ ¢� mz Z) p Oz0 O" O Ozo \�U �� ¢ � I Ln¢� I of w0 0! w0 M 0 L m Z m N L� of m Z L� J� W � J Z O ��" 3 J d d Z 1- W Z �z �Q ° �- o_w� W m W W" LL. LL] w" ¢¢ or ¢¢ V) 0 v, 0 (nZC) (n¢0 ¢� z �\ >J z F- F_ Z O aw aw oZ� 0 oz� o�U Zzw o z =0 o z� o 3¢ 3¢ ¢ F- w w 1 F- O w O w z z � z z x�v Z JOv ZQ m 00 F O F 0 OU 0 OU 0 OU 0 OU w¢ m Z -� N N (n a d v CL .. a v o0 o 0 d X 6 X > > > > F- of z z > > z z 0 0 0 0 N POWER AND CONTROL RISER DIAGRAM SCALE: NONE vqQW&CMED 243 NORTH FRONT ST WILMINGTON, NORTH CAROLINA 28401 _Cape Fear TELE. (910) 343-1048 Public'Utilit Authority FAX: (910) 251-8282 y LICENSE: F-1222 Stewardship. Sustainability. Service. ,A GENERAL NOTES.- OTES:1. aZ 1.REFERENCE SHEET E1 FOR ELECTRICAL NOTES, ABBREVIATIONS AND SYMBOLS. _� o m O m 2. EXPOSED CONDUIT SHALL BE AL CONDUIT UNLESS OTHERWISE NOTED ON PLANS; O m w p aZ mz Wp 30 RGS, IMC AND EMT IS NOT ACCEPTABLE. 30 Q Q z Q Q 3. RACEWAY TRANSITIONS THROUGH CONCRETE AND FINISHED GRADE SHALL BE a Cr om F -Z a o� F -Z PVC -COATED AL CONDUIT. w¢ w¢ 4. ALL FEEDER CONDUCTORS AND CABLING FOR POWER CIRCUITS RATED 100A AND o z0 o OF GREATER SHALL BE STRANDED COPPER 600V XHHW-2. OP F- V)p 5. ALL CONDUCTORS AND WIRES FOR CONTROL CIRCUITS SHALL BE STRANDED COPPER O X w C9 X W 300V THHN/THWN. KEYNOTES: 1A CONTRACTOR SHALL COORDINATE ALL REQUIREMENTS WITH EQUIPMENT SUPPLIER TO ENSURE A COMPLETE AND FULL FUNCTION INSTALLATION 1A 1A HYDRAULIC SYSTEM CENTER UV TRAIN No.1 HYDRAULIC SYSTEM CENTER UV TRAIN No.2 'HSC -1' 'HSC -2' O U U O U m; M m; � Za a O :qk CL o 0 00 0 0 00 p = 3N 3N x x x x 1 aZ o m_ _� o m O m w p °-Z O m w p aZ mz Wp 30 mz wp 30 Q Q z Q Q z O a Cr om F -Z a o� F -Z w¢ w¢ z o z0 o OF OP F- V)p F- V) O X w C9 X W re C9 eo DATE: JUN 2018 SCALE: N/A J DRAWN BY: JAG CAPE FEAR CHECKED BY - REV: I DESCRIPTION I DATE: CAROtt 34f i1(r+J'` SSi 041530 - O ..GINS IGI�� �tittt PUBLIC UTILITY AUTHORITY AWB SO UTH S I D E WWTP PROJECT NO. : -UV DISINFECTION SYSTEM CAPE FEAR PUBLIC UTILITY AUTHORITY 235 GOVERNMENT CENTER DRIVE WILMINGTON, NC 28403 OFFICE: (910)332-6560 0/123-0002 SHEET NO: E6 EXISTING AERATION BLOWER BUILDING GENERAL NOTES : APPROXIMATE LOCATION OF NEW 800A 1. REFERENCE SHEET E1 FOR ELECTRICAL NOTES, ABBREVIATIONS AND SYMBOLS. I ! I MLO PANELBOARD P3 2. EXPOSED CONDUIT SHALL BE AL CONDUIT UNLESS OTHERWISE NOTED ON PLANS; RGS, IMC AND EMT IS NOT ACCEPTABLE. i \--� I - 3. RACEWAY TRANSITIONS THROUGH CONCRETE AND FINISHED GRADE SHALL BE PVC -COATED AL CONDUIT. 4. ALL FEEDER CONDUCTORS AND CABLING FOR POWER CIRCUITS RATED 100A AND j z U' ❑ GREATER SHALL BE STRANDED COPPER 600V XHHW-2. 5. ALL CONDUCTORS AND WIRES FOR CONTROL CIRCUITS SHALL BE STRANDED COPPER THHN 300V THWN. I W APPROXIMATE LOCATION OF EXISTING / PLC/RTU CABINET 1A 16 \\ i' KEYNOTES: ! UGE PROVIDE AND INSTALL NEW NEMA-4X/SS PULL -BOX MOUNTED TO EXTERIOR v� OF BUILDING WITH STAINLESS STEEL STRUT -CHANNEL AND FASTENERS FOR POWER AND CONTROL CIRCUITRY GREATER THAN 90V, PULL -BOX SHALL BE n SIZED PER NEC ARTICLE 314 IN ACCORDANCE WITH THE NUMBER AND SIZE OF RACEWAY ENTRIES AND CONDUCTORS INSTALLED PULL-BOX(ES): COOPER P/N SERIES 202010-4XS OR EQUAL STRUT -CHANNEL: B -LINE P/N B22SH-SS4 OR EQUAL ___---------- -------__---- _____--- ----____---__—_._-_ ---- ----___ i \\- ........... ---_ - 1B PROVIDE AND INSTALL NEW NEMA-4X/SS PULL -BOX MOUNTED TO EXTERIOR V /' / OF BUILDING WITH STAINLESS STEEL STRUT -CHANNEL AND FASTENERS FOR CONTROL CIRCUITRY LESS THAN 90V TO INCLUDE FIBER OPTIC CABLING; I, PULL -BOX SHALL BE SIZED IN ACCORDANCE WITH MINIMUM BENDING RADII OF THE FIBER OPTIC CABLE(S) INSTALLED PULL-BOX(ES): COOPER P/N SERIES 202010-4XS OR EQUAL STRUT -CHANNEL: B -LINE P/N B22SH-SS4 OR EQUAL PROVIDE AND INSTALL REQUIRED RACEWAYS EXPOSED WORK TO MATCH f / EXISTING MATERIALS TO INCLUDE SUPPORTS AND HARDWARE Ln Fn nPROVIDE AND INSTALL CONCRETE ENCASED DUCTBANK, TYPICAL ALL YARD 3A ROUTINGS SD f — '_ SS SS �.�S SS \° �— SD S° __.._ f SS / ss n 3B PROVIDE AND INSTALL CONCRETE REINFORCED DUCTBANK DESIGNED TO MEET S -- SS �.. SS SS — — S n J / AASHTO H-20 LOADING REQUIREMENTS UNDER ALL ROADWAYS EXTENDING SS \_/ \ ss ss 2 -FEET MINIMUM FROM EDGE OF PAVEMENT -- SD s sn s© DB100 — D6110 N 4A PROVIDE AND INSTALL NEW NEMA-4X/SS PULL -BOX MOUNTED TO EXTERIOR o ' OF CHLORINE CONTACT BASIN WITH STAINLESS STEEL STRUT -CHANNEL AND - - - ------- - ----FASTENERS FOR POWER AND CONTROL CIRCUITRY GREATER THAN 90V, PULL -BOX SHALL BE SIZED PER NEC ARTICLE 314 IN ACCORDANCE WITH THE NUMBER AND SIZE OF RACEWAY ENTRIES AND CONDUCTORS INSTALLED PULL -BOX ES : COOPER P N SS AL 1 N STRUT -CHANNEL (ORIZO TALE BIE LINE2P/N B22SHRSS4UOR EQUAL STRUT -CHANNEL (VERTICAL): B -LINE P/N B24ASH-SS4 OR EQUAL n o N O PROVIDE AND INSTALL NEW NEMA-4X/SS PULL -BOX MOUNTED TO EXTERIOR \\ OF CHLORINE CONTACT BASIN WITH STAINLESS STEEL STRUT -CHANNEL AND FASTENERS FOR CONTROL CIRCUITRY LESS THAN 90V TO INCLUDE FIBER OPTIC CABLING; PULL -BOX SHALL BE SIZED IN ACCORDANCE WITH MINIMUM BENDING RADII OF THE FIBER OPTIC CABLE(S) INSTALLED PULL-BOX(ES): COOPER P/N SERIES 202010-4XS OR EQUAL STRUT -CHANNEL (HORIZONTAL): B -LINE P/N B22SH-SS4 OR EQUAL _ _ }! I I 1A 1B 4A 4B { \ ' \ 4A 4B I D131 30 UGE UGE 1 DUCTBANK CALL --OUT INFORMATION DB100 D6120 DUCTBANK WITH THE FOLLOWING RACEWAYS AND CONDUCTORS. Q DUCTBANK WITH THE FOLLOWING RACEWAYS AND CONDUCTORS. 2[3#1 #6G 1-1/4"C] 480V POWER 2[3#1 #6G 1-1/4"C] 480V POWER 3[3#8 #10G 1-C] 480V POWER 3[3#8 #10G 1"C] 480V POWER 1[6#10 #10G 3/4"C] 480V POWER 1[3#10 #10G 3/4"C] 480V POWER 1[3#10 #10G 3/4"C] 480V POWER 1[4#12 #12G 3/4"C 120V POWER 1[12C 62.5UM FO MM CABLE 2"C] FIBER OPTIC 2[10#14 #12G 3/4"C] 120V CONTROLS 2[2C#18 F/FTP #12G 3/4"C] 24V ANALOGUE D8i 10 DUCTBANK WITH THE FOLLOWING RACEWAYS AND CONDUCTORS: 1[12C 62.5UM FO MM CABLE 2"C] FIBER OPTIC 1[6#10 #10G 3/4"C] 480V POWER 1 [4 12 12G 3 1A "1- 120X/ POWER it 2[10#14##12G 3/4"C] 120X/ CONTROLS DB130 DUCTBANK WITH THE FOLLOWING RACEWAYS AND CONDUCTORS: 1[3#1 #6G 1-1 /4"C] 480X/ POWER 2[2C#18 F/FTP #12G 3/4"C] 24X/ ANALOGUE ' 1[3#8 #10G 1-C] 480V POWER 1[3#10 #10G 3/4"C] 480V POWER 1[4#12 #12G 3/4"C 120V POWER 2[10#14 #12G 3/4"C] 120V CONTROLS 2[2C#18 F/FTP #12G 3/4"C] 24V ANALOGUE ELECTRICAL RICAL SITE PLAN 1[12C 62.5UM FO MM CABLE 2"C] FIBER OPTIC SCALE: 1/16" = 1, _ C„ REV: ek�URCM&CMED 0 10' 20' 30' 40' 243 NORTH FRONT ST WILMINGTON, NORTH CAROLINA 28401 INNICapeC Fear 1/16" = 1'-0" TELE: (910) 343-1048 FAX: (910) 251-8282 Public Utility Authority LICENSE: F-1222 Stewardship. Sustainability. Service. n 0 n 0 n V) n STRUT -CHANNEL (VERTICAL): B -LINE P/N B24ASH-SS4 OR EQUAL CIS, MAJOR EQUIPMENT DESCRIPTION /IDENTIFIERS: 1A UV DISINFECTION EQUIPMENT TRAIN No.1 'UV -1A' - 1B UV DISINFECTION EQUIPMENT TRAIN No.2 'UV -2A' DATE: ELECTRICAL SITE PLAN JUN 2018 SCALE: N/A DRAWN BY: A JAG CAPE FEAR CHECKED 8Y iCRIPTION DATE: yyy�yyrrrr,rJJ' CARa/'�,,, sSi ' 14, SES-- - 041330 - `;' 15Zr � w ` f+irriyty PUBLIC UTILITY AUTHORITY AWB S O U T H S I D E W WT P PROJECT NO. 07123-0002 _UV DISINFECTION SYSTEM CAPE FEAR PUBLIC UTILITY AUTHORITY 235 GOVERNMENT CENTER DRIVE WILMINGTON, NC 28403 OFFICE: (910)332-6560 SHEET NO: E7 ELECTRICAL INSTALLATION NOTES: DA 1. ELECTRICAL EQUIPMENT AND ENCLOSURES ARE SHOWN APPROXIMATE TO INCLUDE RECOMMENDED ---- LOCATIONS. CONTRACTOR SHALL REFERENCE ALL CONTRACT DOCUMENTS, APPROVED EQUIPMENT TO LP-100/CKT-2 �-- \ SUBMITTALS AND MANUFACTURER INSTALLATION INSTRUCTIONS PRIOR TO COMMENCING INSTALLATION. TO SCC f 2. RACEWAY ROUTINGS ARE NOT SHOWN; CONTRACTOR SHALL INSTALL RACEWAYS AS REQUIRED PER THE 4A \\ CONTRACT SCOPE OF WORK. \' 3. EXPOSED RACEWAYS SHALL BE ARRANGED IN A NEAT MANNER UTILIZING CONCENTRIC BENDS WITH COMMON SUPPORTS AND HANGERS IN LOGICAL GROUPINGS. TO SCC �--- 3.1. MULTIPLE SINGULAR RACEWAYS AND SUPPORTS ARE NOT ACCEPTABLE. - --- - ---------- - 4. CONTRACTOR SHALL REFERENCE ALL CONTRACT DRAWINGS AND DOCUMENTS, APPROVED EQUIPMENT SUBMITTALS AND MANUFACTURER'S INSTALLATION INSTRUCTIONS PRIOR TO INSTALLING RACEWAYS INTO CONCRETE FORM WORK AND REBAR PLACEMENT. 7A ' O 4)1 LP-100/CK-81 WP/GFCI IT I I � I TO DIS -PDC -IA -1C / I TO SCC , 2B I il ------. --1'. • oliw*ww**wi ----------- I 2F I TO DIS -HSC -1 , I / I I I TO P3 2C TO P3 2E TO P3 2G TO LP-100/CKT-1 3A 49114 LP-100/CKT-6 WP/GFCI L1 10A O —► TO LP- 100/CKT-4 --► TO SCC - GENERAL NOTES: --► TO P3 II / 76 1. REFERENCE SHEET E1 FOR ELECTRICAL NOTES, ABBREVIATIONS AND SYMBOLS. ' -► TO P3 2. EXPOSED CONDUIT SHALL BE AL CONDUIT, RGS, IMC AND EMT IS NOT ACCEPTABLE I / 3. ALL FEEDER CONDUCTORS AND CABLING FOR POWER CIRCUITS RATED 100A AND 6B GREATER SHALL BE STRANDED COPPER 600V XHHW-2. --► TO SCC 4. ALL CONDUCTORS AND WIRES FOR CONTROL CIRCUITS SHALL BE STRANDED COPPER vREV: v & CREED 12„ 0 5' 10' 15' 243 NORTH FRONT ST y WILMINGTON, NORTH CAROLINA 28401 Cape Fear 3/16 = 1'-0" TELE: (910) 343-1048 FAX: (910) 251-8282 Public Utility Authority LICENSE: F-1222 Stewardship. Sustainability. Service. ---am-TO P -JB -1000 300V THHN/THWN. KEYNOTES: / `i► TO A/D-JB-1000 MAJOR EQUIPMENT DESCRIPTION.ADENTIFIERS: 1A INDUSTRIAL GRADE 125V/20A GFIC OUTLET WITH LED POWER INDICATOR: 1A UV DISINFECTION EQUIPMENT TRAIN No.1 'UV -1A' O UV DISINFECTION EQUIPMENT TRAIN No.2 'UV -2A' 3A UV SYSTEM CONTROL CENTER 'SCC' 1B UV POWER DISTRIBUTION '' CABINET TRAIN No.1 PDC-1A-1C 2B O UV POWER DISTRIBUTION CABINET '' TRAIN No.1 'PDC -1A -1C' 4A O ON-LINE UV TRANSMITTANCE CONTROLLER 'RTO / RE -3000' 1C UV POWER DISTRIBUTION CABINET DISCONNECT 'DIS -PDC -1A -1C' UV POWER DISTRIBUTION CABINET DISCONNECT 'DIS -PDC -1A -1C' SA INFLUENT FLASH MIX FLOW TRANSMITTER 'FIT -3000' 1D UV POWER DISTRIBUTION CABINET TRAIN No.1 'PDC -1D' 2D UV POWER DISTRIBUTION CABINET TRAIN No.1 'PDC -1D' 6A MOTOR OPERATED VALVE TRAIN No.1 'MOV -1000' 1E UV POWER DISTRIBUTION CABINET DISCONNECT 'DIS -PDC -1D' 2E UV POWER DISTRIBUTION CABINET DISCONNECT 'DIS -PDC -1D' 66 MOTOR OPERATED VALVE DISCONNECT 'DIS -MOV -1000' 1F HYDRAULIC SYSTEM CENTER TRAIN No.1 'HSC -1' 2F HYDRAULIC SYSTEM CENTER TRAIN No.1 'HSC -1' 7A MOTOR OPERATED VALVE TRAIN No.1 'MOV -1000' 1G HYDRAULIC SYSTEM CENTER DISCONNECT 'DIS -HSC -1' 2G HYDRAULIC SYSTEM CENTER DISCONNECT 'DIS -HSC -1' 7B MOTOR OPERATED VALVE DISCONNECT 'DIS -MOV -1000' 1H UV LAMP ASSEMBLIES TRAIN No.1 IS UV LAMP ASSEMBLIES TRAIN No.1 O UNIT POWER SUBSTATION 'LP -100' ELECTRICAL POWER PLAN (W$P/GFCI SCALE: 3/16" = 1' — 0» 01 vREV: v & CREED 12„ 0 5' 10' 15' 243 NORTH FRONT ST y WILMINGTON, NORTH CAROLINA 28401 Cape Fear 3/16 = 1'-0" TELE: (910) 343-1048 FAX: (910) 251-8282 Public Utility Authority LICENSE: F-1222 Stewardship. Sustainability. Service. DATE: JUN 2018 SCALE: N/A DRAWN BY: JAG CAPE FEAR CHECKED AY* DESCRIPTION DATE: lt�llrrltrr,Jrr Ss�'• SE 041530 '17- s n t' w rl rJ!l1 Filo ilii PUBLIC UTILITY AUTHORITY AWB S O U T H S I D E W WT P PROJECT NO.: 07123-0002 UV DISINFECTION SYSTEM CAPE FEAR PUBLIC UTILITY AUTHORITY 235 GOVERNMENT CENTER DRIVE WILMINGTON, NC 28403 OFFICE: (910)332-6560 SHEET NO: E8 300V THHN/THWN. KEYNOTES: 1A INDUSTRIAL GRADE 125V/20A GFIC OUTLET WITH LED POWER INDICATOR: PASS & SEYMOUR P/N 2095TRWRNAI OR APPROVED EQUAL WEATHER -RESISTANT DIE-CAST IN -USE COVER: MULBERRY P/N 30936 OR APPROVED EQUAL II (TYPICAL ALL EXTERIOR OUTLET ASSEMBLIES) jLP-100/CKT-6 (W$P/GFCI r f 1A I I I / •� �` -01 TO DIS -PDC -1A -1C 1B TO SCC I � i 1H --► TO DIS -PDC -1D TO SCC I I 1F I I I / i TO DIS -HSC -1 1 C TO P3 1E / -- - TO P3 1G TO P3 — TO P3 TO P -PB -1000 I 0 LP-loo/CKT-8 LJ LJ 1 ;Ip-_ WP/GFCI - - 96 9A P. TO P3 ---► TO P -JB -2000 RECEPTACLE INSTALLATION NOTES: -► TO PLC/RTU CABINET 1. THREE-PHASE, MULTI -CIRCUIT RECEPTACLE BRANCH CIRCUITS SHALL NOT — / -- ---► TO A/D-PB-2000 SHARE NEUTRAL CONDUCTOR. 2. CONTRACTOR SHALL INSTALL SEPARATE NEUTRAL CONDUCTOR FOR EACH BRANCH PHASE CIRCUIT CONDUCTOR. 9A POWER PULL -BOX 'P -PB -1000' 3. CONTRACTOR SHALL TEST SEPARATE NEUTRAL CONDUCTORS PRIOR TO CONNECTIONS. 9B SIGNAL PULL BOX 'A/D-JB-1000' 4. ALL NEUTRAL AND BRANCH PHASE CIRCUIT CONDUCTORS SHALL BE LABELED IN ACCORDANCE WITH THE PANEL CIRCUIT NUMBER IN EVERY JUNCTION, PULL 10A POWER PULL' -BOX 'P -PB -2000' AND DEVICE BOX. 10B SIGNAL PULLBOX 'A/D-JB-2000' DATE: JUN 2018 SCALE: N/A DRAWN BY: JAG CAPE FEAR CHECKED AY* DESCRIPTION DATE: lt�llrrltrr,Jrr Ss�'• SE 041530 '17- s n t' w rl rJ!l1 Filo ilii PUBLIC UTILITY AUTHORITY AWB S O U T H S I D E W WT P PROJECT NO.: 07123-0002 UV DISINFECTION SYSTEM CAPE FEAR PUBLIC UTILITY AUTHORITY 235 GOVERNMENT CENTER DRIVE WILMINGTON, NC 28403 OFFICE: (910)332-6560 SHEET NO: E8 G— G G G G G G G #4/OAWG BARE CU (BURIED 18—INCH MIN. BELOW FINISHED GRADE) G G G - G ,A 3A 3B GENERAL NOTES: 1. REFERENCE SHEET E1 FOR ELECTRICAL NOTES, ABBREVIATIONS AND SYMBOLS. 2. EXPOSED CONDUIT SHALL BE AL CONDUIT; RGS, IMC AND EMT IS NOT ACCEPTABLE 3. ALL FEEDER CONDUCTORS AND CABLING FOR POWER CIRCUITS RATED 100A AND GREATER SHALL BE STRANDED COPPER 600V XHHW-2. G G G G • 4 ALL CONDUCTORS AND WIRES FOR CONTROL CIRCUITS SHALL BE STRANDED COPD LD i I — CD i j 2C 2C I .01 II � I� I � I I � I I � I i G .I G { 26AAAAAAAAA I I I 400, Nil I I � I I I I / I I I 2B 26 ( I I I � I I I I I I I cI I 2B � � _ — 26 . � I I HE mum 2B 6. IrG � I 3A 3B ELECTRICAL GROUNDING PLAN SCALE: 3/1611 = 11 _ 0» v &OEED 12" 0 5' 10' 15' 243 NORTH FRONT ST — WILMINGTON, NORTH CAROLINA 28401 `Cape Fear 3/16 — 1'-0" TELE. (910) 343-1048 PUbIIC UtilityAuthor FAX: (910) 251-8282 Authority LICENSE: F-1222 Stewardship. Sustainability. Service. 0 0 0 0 0 0 0 0 0 A 0 0 ER 3A 3B ELECTRICAL GROUNDING PLAN SCALE: 3/1611 = 11 _ 0» v &OEED 12" 0 5' 10' 15' 243 NORTH FRONT ST — WILMINGTON, NORTH CAROLINA 28401 `Cape Fear 3/16 — 1'-0" TELE. (910) 343-1048 PUbIIC UtilityAuthor FAX: (910) 251-8282 Authority LICENSE: F-1222 Stewardship. Sustainability. Service. 0 0 0 0 0 0 0 0 0 A 0 0 300V THHN/THWN. GROUNDING KEYNOTES: 1A PERIMETER GROUNDING RING SHOWN APPROXIMATE, CONTRACTOR SHALL ROUTE AS REQUIRED TO AVOID UNDERGROUND MECHANICAL PIPING AND STRUCTURAL FEATURES ® NOT USED THIS SHEET O2B BOND ELECTRICAL EQUIPMENT WITH BARE #2AWG TINNED CU WIRE USING MECHANICAL LUG CONNECTIONS USING STAINLESS—STEEL ANTI—VIBRATION FASTENERS OBOND STRUCTURAL FRAME MEMBERS WITH BARE #2AWG TINNED CU WIRE USING 2C MECHANICAL LUG CONNECTIONS USING STAINLESS—STEEL ANTI—VIBRATION 3D FASTENERS 3A 3/4" x 120" CU—CLAD GROUND ROD 3B EXOTHERMIC WELD 4/OAWG CABLE TO 3/4" GROUND ROD (TYPE—GT OR EQUAL) 3C NOT USED THIS SHEET 3D EXOTHERMIC WELD 4/OAWG CABLE RUN TO #2AWG CABLE TAP (TYPE—TA OR EQUAL) 3D c� 3D 3D 3D c� 3D 0 0 0 • 3A 36 DATE: ELECTRICAL GROUNDING PLAN JUN 2018 SCALE: N/A DRAWN BY: JAG CAPE FEAR CHECKED BY: REV: DESCRIPTION DATE: CARO r!, sS1 y Q 9 S 041530 5• r 2015 �jt�i lli:Sl PUBLIC UTILITY AUTHORITY AWB SOUTHSIDE WWTP PROJECT NO. 07123-0002 UV DISINFECTION SYSTEM CAPE FEAR PUBLIC UTILITY AUTHORITY 235 GOVERNMENT CENTER DRIVE WILMINGTON, NC 28403 OFFICE: (910)332-6560 SHEET NO: E9 ER 0 0 0 • 3A 36 DATE: ELECTRICAL GROUNDING PLAN JUN 2018 SCALE: N/A DRAWN BY: JAG CAPE FEAR CHECKED BY: REV: DESCRIPTION DATE: CARO r!, sS1 y Q 9 S 041530 5• r 2015 �jt�i lli:Sl PUBLIC UTILITY AUTHORITY AWB SOUTHSIDE WWTP PROJECT NO. 07123-0002 UV DISINFECTION SYSTEM CAPE FEAR PUBLIC UTILITY AUTHORITY 235 GOVERNMENT CENTER DRIVE WILMINGTON, NC 28403 OFFICE: (910)332-6560 SHEET NO: E9 .III - I - TO LP-100/CKT-5 ELECTRICAL LIGHTING PLAN SCALE: 3/16„ _ 1, , 0» v D 243 NORTH FRONT ST 12" 0 5' 10' 15 WILMINGTON, NORTH CAROLINA 28401 3/16» _ 1'-0" 0 TELE: FAX: ((9 0)) 251-8282 �2 LICENSE: F-1222 IMCape Fear Public Utility Authority Stewardship. Sustainability. Service, REV: DESCRIPTION DATE: 01 DATE: JUN 2018 SCALE: N/A DRAWN BY: I JAG ti�,���rtttrJtt CARQ''�,, ,..sem = 041530 Of/��•�� •/�G/ttN{fit. •fir"` .�' PUBLIC UTILITY AUTHORITY SOUTHSI DE WWTP UV DISINFECTION SYSTE CAPE FEAR PUBLIC UTILITY AUTHORITY 235 GOVERNMENT CENTER DRIVE WILMINGTON, NC 28403 OFFICE: (910)332-6560 CHECKED BY: AWB PROJECT NO. 07123-0002 r SHEET NO: E10 GENERAL NOTES: 1. REFERENCE SHEET E1 FOR ELECTRICAL NOTES, ABBREVIATIONS AND SYMBOLS. 2. EXPOSED CONDUIT SHALL BE AL CONDUIT; RGS, IMC AND EMT IS NOT ACCEPTABLE 3. ALL FEEDER CONDUCTORS AND CABLING FOR POWER CIRCUITS RATED 100A AND GREATER SHALL BE STRANDED COPPER 600V XHHW-2. 4. ALL CONDUCTORS AND WIRES FOR CONTROL CIRCUITS SHALL BE STRANDED COPPER 300V THHN/THWN. KEYNOTES: 1A INDUSTRIAL GRADE 120/277V 20A 2P TOGGLE SWITCH IVORY: PASS & SEYMOUR P/N PS20AC21 OR EQUAL WEATHER -RESISTANT DIE-CAST COVER WITH ACTUATING LEVER: LEGRAND P/N CA1GL OR EQUAL (TYPICAL OF 2 ASSEMBLIES) ® INDUSTRIAL GRADE 120V LED WET LOCATION LIGHT FIXTURE: LITHONIA P/N VAP- 8000-PCL-WD-MVOLT- 40K-80CR1-STSL OR EQUAL (TYPICAL OF 6) 2B LIGHT FIXTURES SHALL BE MOUNTED TO COMMON STAINLESS-STEEL STRUT -CHANNEL WHICH SHALL BE FASTENED TO STRUCTURAL MEMBERS UTILIZING STAINLESS-STEEL THREADED ROD, THREADED ROD SWIVEL COUPLINGS AND BEAM CLAMPS (TYPICAL ALL) 2C LIGHT FIXTURES SHALL BE MOUNTED TO COMMON STAINLESS-STEELSTRUT-CHANNEL UTILIZING LIGHT FIXTURE MOUNTING POINTS - CONTRACTOR SHALL NOT DRILL OR I MAKE ADDITIONAL OPENINGS IN LIGHT FIXTURE HOUSING I (TYPICAL ALL) 2D LIGHT FIXTURES SHALL WIRED USING #12/3 SOOW CORD WITH ALUMINUM CABLE GLAND CONNECTORS - CONTRACTOR SHALL MAINTAIN INTEGRITY OF LIGHT FIXTURE I HOUSING (TYPICAL ALL) I 2A 2B I LJ 2C 2D I I I I I I I 1 I I 1 I I I I I LJ � � --► TO LP-100/CKT-3 L_j ED REV: DESCRIPTION DATE: 01 DATE: JUN 2018 SCALE: N/A DRAWN BY: I JAG ti�,���rtttrJtt CARQ''�,, ,..sem = 041530 Of/��•�� •/�G/ttN{fit. •fir"` .�' PUBLIC UTILITY AUTHORITY SOUTHSI DE WWTP UV DISINFECTION SYSTE CAPE FEAR PUBLIC UTILITY AUTHORITY 235 GOVERNMENT CENTER DRIVE WILMINGTON, NC 28403 OFFICE: (910)332-6560 CHECKED BY: AWB PROJECT NO. 07123-0002 r SHEET NO: E10 3. IN REGARDS TO DUCT BANK CONSTRUCTION, NOTE THE FOLLOWING: a.) CONCRETE 28 -DAY COMPRESSIVE STRENGTH = 2,500 PSI (MIN.). b.) CONCRETE DIMENSION BTWN. CJ's = 60'-0" (MAX.). c.) AT CONSTRUCTION JT.'s BETWEEN SECTIONS SPLICE CORNER BARS 1'-9" (MIN.) w/ CORNER BARS FOR THE ADJOINING POUR. 4. ALTHOUGH DETAIL SHOWS AN UNDER ASPHALT PAVED ROAD CONDITION, THIS DETAIL MAY BE UTILIZED FOR UN -REINFORCED DUCT BANK BELOW GRADE LOCATIONS. TYPICAL REINFORCED ED CONCRETE DUCTBANK UNDER ROADWAYS SCALE: 1/2 = 1'-0" REV:7 DESCRIPTION DATE: v &CRXED 243 NORTH FRONT ST WILMINGTON, NORTH CAROLINA 28401 _Cape Fear TELE: (910) 343-1048 FAX: (910) 251-8282 Public Utility Authority LICENSE: F-1222 Stewardship. Sustainability. Service. PICAL ETAILS mu CAPE FEAR PUBLIC UTILITY AUTHORITY SOUTHSI DE WWTP UV DISINFECTION SYSTEM CAPE FEAR PUBLIC UTILITY AUTHORITY 235 GOVERNMENT CENTER DRIVE WILMINGTON, NC 28403 OFFICE: (910)332-6560 eo DATE: JUN 2018 SCALE: N/A DRAWN BY - JAG CHECKED BY: AWB PROJECT NO. 07123-0002 (SHEET NO: E11 CONDUIT AS REQUIRED GROUNDING RING CONDUCTOR TYPE 'TA' EXOTHERMIC WELD MOLD CLEAN COMPACTED FILL PVC -COATED RAC CONDUIT TRANSITION THROUGH WITH STONE LESS THAN 3/4" CONCRETE, FLOOR SLAB OR FINISHED GRADE GROUNDING TAP CONDUCTOR ----._._ EXOTHERMIC WELD 'TA' CONNECTION 12" MIN SCALE: N.T.S. CONCRETE, FLOOR SLAB OR FINISHED GRADE a 4 SEE NOTE 1. I_-- - - ------------ - — ---- ---- ---. TYPE 'GT' EXOTHERMIC -----_------ ------------- ----J -- _ ---- --- --- WELD MOLD— ------------------ ----____ __ __ _____ i - PVC -COATED RAC CONDUIT ELBOW FOR 1I CABLE PULLING REQUIREMENTS CLEAN COMPACTED SAND CU -CLAD GROUND ROD PVC SCH-40 OR SCH-80 CONDUIT WITH 4" MIN. ENVELOPE GROUNDING CONDUCTOR AROUND CONDUIT OR DUCTBANK EXOTHERMIC WELD 'GT' CONNECTION 1. BURIAL DEPTH OF CONDUIT OR DUCTBANK SHALL BE BASED ON THE LARGEST CONDUIT RADII SUCH SCALE: N.T.S. THAT THE THREADED CONNECTION TO THE PVC -COATED RGS CONDUIT TRANSITION IS 6" MINIMUM - BELOW BOTTOM OF CONCRETE FLOOR SLAB. TYPICAL UNDERSLAB CONDUIT STUB -UP INSTALLATION SCALE: N.T.S. NON -HARDENING SILICONE SEALANT - 9 FINISHED FLOOR I 4 PVC BELL -END FITTING 12 MIN. CONCRETE4 4 a PVC SCH-80 CONDUIT 4 4� GROUND CABLE DUCT BANK ASSEMBLY BELOW ASPHALT TOP COURSE PER PROJECT REQUIREMENTS (REF. NOTE 2) BASE COURSE PER PROJECT REQUIREMENTS GROUND CABLE SLEEVE DETAIL .O. ASPHALT PVMT. (REF. NOTE 2) SCALE: N.T.S. EL VARIES z (FIELD COORD. AS REQ'D) COMPACTED FILL/SUBGRADE PER PROJECT = [REF. NOTE 41 REQUIREMENTS (REF. NOTE 2) of SCH-40 PVC CONDUITS Nil (TYP.) il T.O. CONC. DUCT BANK 4.. EL VARIES e (FIELD COORDINATE AS REQ'D) o N E.O. C.I.P. CONC. DUCT BANK (TYP.) < [REF. NOTE 3] #4 "U" -BAR SHAPED TIES SPA. ® 12" O.C. (T&B) z _j.� Z U 3" 1'-5" (MIN.) n 1'-5" n10 v 3" CLR. 6" MIN. (4) CONT. #4 BARS (TYP.) (TYP.) 1'-5"I 11'-5" (1 EA. CORNER) 2'-0" u [REF. NOTE 3.c] DETAIL NOTES: 1. NOT USED. 2. IN REGARDS TO THE PAVING BOX SECTION, IN ADDITION TO ASPHALT THICKNESS, THE AGGREGATE, GEOTEXTILE & COMPACTED FILL/SUBGRADE ARE ALL IN 'ACCORDANCE WITH THE SPECIFICATIONS AND TYPICAL PAVING SECTIONS AND DETAILS 3. IN REGARDS TO DUCT BANK CONSTRUCTION, NOTE THE FOLLOWING: a.) CONCRETE 28 -DAY COMPRESSIVE STRENGTH = 2,500 PSI (MIN.). b.) CONCRETE DIMENSION BTWN. CJ's = 60'-0" (MAX.). c.) AT CONSTRUCTION JT.'s BETWEEN SECTIONS SPLICE CORNER BARS 1'-9" (MIN.) w/ CORNER BARS FOR THE ADJOINING POUR. 4. ALTHOUGH DETAIL SHOWS AN UNDER ASPHALT PAVED ROAD CONDITION, THIS DETAIL MAY BE UTILIZED FOR UN -REINFORCED DUCT BANK BELOW GRADE LOCATIONS. TYPICAL REINFORCED ED CONCRETE DUCTBANK UNDER ROADWAYS SCALE: 1/2 = 1'-0" REV:7 DESCRIPTION DATE: v &CRXED 243 NORTH FRONT ST WILMINGTON, NORTH CAROLINA 28401 _Cape Fear TELE: (910) 343-1048 FAX: (910) 251-8282 Public Utility Authority LICENSE: F-1222 Stewardship. Sustainability. Service. PICAL ETAILS mu CAPE FEAR PUBLIC UTILITY AUTHORITY SOUTHSI DE WWTP UV DISINFECTION SYSTEM CAPE FEAR PUBLIC UTILITY AUTHORITY 235 GOVERNMENT CENTER DRIVE WILMINGTON, NC 28403 OFFICE: (910)332-6560 eo DATE: JUN 2018 SCALE: N/A DRAWN BY - JAG CHECKED BY: AWB PROJECT NO. 07123-0002 (SHEET NO: E11 m M E N 0 0 0 l M N n 0 Ir L2 W It x E n N 0 0 N U) 0 0 a m J T J GENERAL NOTES: 1.0 GENERAL 1.1 ALL WORK IS TO BE PERFORMED IN A GOOD, 5.2 CONCRETE WORK SHALL CONFORM TO "BUILDING CODE 8.10 STRUCTURAL STEEL COMPONENTS & ASSEMBLIES ARE WORKMANLIKE AND PROFESSIONAL MANNER. REQUIREMENTS FOR REINFORCED CONCRETE", ACI 318 & TO TO BE REVIEWED BY THE THE OWNER'S CONSTRUCTION "CODE REQUIREMENTS FOR ENVIRONMENTAL ENGINEERING REPRESENTATIVE THROUGHOUT MASONRY & STEEL 1.2 ALL CONSTRUCTION SHALL BE IN STRICT COMPLIANCE CONCRETE STRUCTURES", ACI 350 (LATEST EDITIONS). CONSTRUCTION OF THE PROJECT. THESE REVIEWS SHALL WITH THE REQUIREMENTS OF THE NORTH CAROLINA STATE CONFORM TO THE REQUIREMENTS OF CHAPTER 17 OF THE BUILDING CODE, LATEST EDITION, OR LOCAL BUILDING CODE 5.3 PLACE 1/2 INCH EXPANSION JOINT MATERIAL BETWEEN NORTH CAROLINA STATE BUILDING CODE. REQUIREMENTS IF MORE STRINGENT. EDGES OF SLABS AND VERTICAL SURFACES UNLESS NOTED OTHERWISE. 9.0 ALUMINUM 1.3 THESE DRAWINGS DO NOT SHOW PROVISIONS FOR SAFETY DURING CONSTRUCTION. IT IS THE RESPONSIBILITY OF THE 5.4 CHAMFER EXPOSED EDGES OF CONCRETE 3/4 INCH, 9.1 ALUMINUM FABRICATION SHALL BE IN CONFORMANCE GENERAL CONTRACTOR TO PROVIDE THE REQUIRED BRACING, UNLESS NOTED OTHERWISE. WITH THE ALUMINUM ASSOCIATION, INC. "SPECIFICATIONS SHORING, AND SAFETY DEVICES THROUGHOUT THE FOR ALUMINUM STRUCTURES". CONSTRUCTION OF THIS PROJECT. 5.5 CONTRACTOR SHALL BE RESPONSIBLE FOR PROPER 2.0 COORDINATION CURING OF ALL CONCRETE. FOOTINGS SHALL BE MOISTURE 9.2 UNLESS NOTED OTHERWISE, MATERIALS SHALL BE: CURED. CURING METHODS SHALL CONFORM TO "BUILDING a. PLATE & SHEET - ASTM B209; 6061-T6, 6061-T651 2.1 STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION CODE REQUIREMENTS FOR REINFORCED CONCRETE", ACI 318, "CODE ALLOY. b. EXTRUDED SHAPES - ASTM B221; 6061-T6, 6061-T651 WITH AND COORDINATED WITH CIVIL, DETAIL & MECHANICAL REQUIREMENTS FOR ENVIRONMENTAL ENGINEERING ALLOY. PIPE SECTIONS ARE SCHEDULE 40 U.N.O.. DRAWINGS AND OTHER CONTRACT DOCUMENTS. CONCRETE STRUCTURES" ACI 350 AND "STANDARD PRACTICE c. CASTINGS - ASTM B108; 214 ALLOY. FOR CURING CONCRETE," ACI 308, LATEST EDITIONS. d. BOLTS - ASTM A193; GRADE B8 OR, ASTM 276; TYPE 2.2 ANY DISCREPANCIES BETWEEN ACTUAL CONDITIONS AND 316 STAINLESS STEEL. THOSE SHOWN ON THESE DRAWINGS ARE TO BE BROUGHT TO 5.6 UNLESS NOTED OTHERWISE DOWELS SHALL BE THE SAME e. NUTS - ASTM A194; GRADE M, OR ASTM 276; TYPE 316 THE ATTENTION OF THE STRUCTURAL ENGINEER BEFORE NUMBER AND SIZE AS THE LARGEST VERTICAL BAR TO STAINLESS STEEL. WORK PROCEEDS, INCLUDING ORDERING AND FABRICATING WHICH THEY ARE SPLICED. MATERIALS. 9.3 ALUMINUM SHALL BE SEPARATED FROM DIRECT CONTACT 5.8 REQUIRED FINISHES AS FOLLOWS: WITH OTHER MATERIALS (STEEL, CONCRETE, ETC.) BY 2.3 INDEPENDENT TESTING OF MATERIALS SHALL BE a.) SLABS: PRESSURE SENSITIVE TAPE, BITUMASTIC COATING, OR OTHER PROVIDED AS DEFINED ON THIS DRAWING. IN GENERAL TOPS: UNFORMED, FLOATED & TROWELED SMOOTH -PROTECTIVE METHOD SUBMITTED BY THE CONTRACTOR AND PROJECT INVOLVES THE FOLLOWING: A. CONCRETE. AND LEVEL. APPROVED BY THE OWNER'S CONSTRUCTION REPRESENTATIVE. SIDES: ROUGH FORMED FINISH IF UNEXPOSED & 2.4 IF COORDINATION OF INFORMATION PRESENTED CONFLICTS SMOOTH FORMED FINISH IF EXPOSED. 9.4 CONNECTIONS SHALL HAVE A MINIMUM OF TWO 3/4- w/ THE PROJECT SPECIFICATIONS, THE DRAWINGS WILL TAKE 5.9 CONTRACTOR SHALL SUBMIT REBAR SHOP DRAWINGS FOR DIAMETER STAINLESS STEEL BOLTS. PRECEDENCE. APPROVAL TO OWNER PRIOR TO FABRICATION. DO NOT 9.5 WELDING ALUMINUM SHALL CONFORM TO AWS D1.2 & 2.5 IN GENERAL CALL -OUTS ARE FOR NEW CONSTRUCTION FABRICATE REINFORCING PRIOR TO RECEIPT OF APPROVED SHOP DRAWINGS. AWS A5.10 AND THE REQUIREMENTS OF THE ALUMINUM "ALUMINUM U.N.O.. EXISTING CONSTRUCTION CALL -OUTS, ELEVATIONS ASSOCIATIONS DESIGN MANUAL" LATEST EDITION ( ) AND DIMENSIONS OF EXISTING STRUCTURES ARE BASED ON 5.10 CONCRETE MIXES TO BE REVIEWED BY THE OWNER'S TABLE 7.1-1 FOR WELD FILLERS FOR WROUGHT ALLOYS. FIELD DIMENSIONS & EXISTING RECORD DRAWINGS PROVIDED TO McKIM & CREED. THE (*) SYMBOL ON INDIVIDUAL9.6 CONSTRUCTION REPRESENTATIVE PRIOR TO PLACEMENT OF REFERENCE PROJECT SPECIFICATIONS FOR HANDRAIL "STRUCTURAL" CONCRETE. COMPRESSIVE STRENGTH TEST CYLINDERS TO BE REQUIREMENTS. FACILITY DRAWINGS INDICATES EXISTING REVIEWED BY THE OWNER'S CONSTRUCTION REPRESENTATIVE CONSTRUCTION CALL -OUTS, CONDITIONS, ELEVATIONS AND THROUGHOUTCONCRETE CONSTRUCTION OF THE PROJECT. 10.0 PRE -CAST CONCRETE (NOT APPLICABLE) DIMENSIONS TO BE FIELD VERIFIED BY THE GENERAL THESE REVIEWS SHALL CONFORM TO THE REQUIREMENTS OF CONTRACTOR U.N.O. PRIOR TO CONSTRUCTION, INCLUDING CHAPTER 17 OF THE NORTH CAROLINA STATE BUILDING 11,0 OPEN WEB STEEL JOISTS NOT APPLICABLE ( ) ORDERING AND FABRICATING MATERIALS. RECORD DRAWINGS CODE. PROVIDED UTILIZED INCLUDES: A. CITY OF WILMINGTON "CHLORINE CONTACT 6.0 GROUT 12.0 TIMBER TRUSSES (NOT APPLICABLE) TANK -PLAN, SECTIONS, & DETAILS" PROJECT BY OLSEN ASSOCIATES - ENGINEER & ARCHITECTS (DTD. 6.1 PROVIDE NON -SHRINK GROUT UNDER ALL COLUMN BASE 13.0 MISCELLANEOUS BUILDING MATERIALS JULY 1969). PLATES AND ,BEAM BEARING PLATES AND ELSEWHERE AS INDICATED ON DRAWINGS. NON -SHRINK GROUT SHALL 13.1 ALL MISCELLANEOUS MATERIALS ARE TO BE DELIVERED 2.6 SPECIAL INSPECTIONS (IF APPLICABLE): ALL CONFORM TO ASTM C 1107. TO SITE & STAGED ON SITE PRIOR TO INSTALLATION. iiISTORE ON SITE AS REQUIRED BY THE MATERIAL MANUFACTURER TO FOUNDATIONS, REINF. STEEL, C.I.P. CONCRETE, STRUCTURAL 6.2 GROUT SHALL BE NON-METALLIC AND NON -STAINING AVOID DAMAGE PRIOR TO INSTALLATION. STEEL, WORK SHALL BE REVIEWED AS STATED IN CONJUNCTION w/ THEIR RESPECTIVE NOTES BELOW, CHAPTER AND HAVE A MINIMUM COMPRESSIVE STRENGTH OF 5,000 psi. 13.2 ALL MATERIALS SHALL BE SUBMITTED AS A SYSTEM 17 OF THE NORTH CAROLINA STATE BUILDING CODE AND THE 7.0 MASONRY ( NOT APPLICABLE) COMPATIBLE w/ EACH OTHER AND THE APPROVED CMU WALL PROJECT SPECIAL INSPECTIONS STATEMENT. SYSTEM & COLOR. ALL MATERIAL STYLES & COLORS SHALL 3.0 FOUNDATIONS NOT APPLICABLE ( ) 8.0 STRUCTURAL STEEL BE SUBMITTED TO THE OWNER FOR APPROVAL. PRIOR' TO CONSTRUCTION PROVIDE MATERIAL SAMPLES & MOCK 4.0 REINFORCING STEEL 8.1 STEEL SHALL CONFORM TO "STANDARD SPECIFICATION ASSEMBLIES AS REQUIRED BY THE OWNER. THE TERM "CONSTRUCTION" INCLUDES ORDERING, FABRICATION OF FOR STRUCTURAL STEEL," ASTM A36 (Fy=36 ksi) FOR 4.1 BARS SHALL BE ROLLED FROM NEW BILLET -STEEL OF ANGLES, PLATES AND CHANNELS. WIDE FLANGE SECTIONS MATERIALS &DELIVERY TO PROJECT SITE. DOMESTIC MANUFACTURE CONFORMING TO "STANDARD SHALL CONFORM TO ASTM A572 (Fy=50ksi). HOLLOW STEEL 13.3 ROOF SHALL BE OR AN APPROVED EQUAL. ROOF SPECIFICATION FOR DEFORMED AND PLAIN BILLET STEEL SECTIONS (HSS) SHALL CONFORM TO ASTM A500, GRADE B SHALLPANELS ^TO ADESIGN (LOADS" BARS FOR CONCRETE REINFORCEMENT," ASTM A 615, GRADE (Fy=46 ksi). STEEL PIPE SHALL CONFORM TO ASTM A53, CLU ES IN SERVE RATING RESIST 60 AND SUPPLEMENTARY REQUIREMENT S-1. GRADE B. (Fy=35 ksi). WIND SPEED. 4.2 DETAIL AND FABRICATE REINFORCING STEEL IN "ACI 8.2 WELDING SHALL BE IN ACCORDANCE WITH THE LATEST 13.4 SIDING MATERIAL SHALL BE ... TYPE ? PROFILE w ACCORDANCE WITH THE AMERICAN CONCRETE INSTITUTE EDITION OF THE AMERICAN WELDING SOCIETY AWS D1.1 0.044" THICK MIN. PANELS THAT ARE DURABLE WIND (MIN.) & DETAILING MANUAL," LATEST PUBLICATION. "STRUCTURAL WELDING CODE". WELDING SHALL BE RESISTANT. SOFFITT PANELS SHALL BE VENTILATED. PERFORMED BY CERTIFIED PERSONNEL WHO HAVE BEEN 4.3 REINFORCING STEEL IN PLACE SHALL BE REVIEWED BY PREVIOUSLY QUALIFIED BY TEST PRESCRIBED IN THE AWS 13.5 GUTTER & DOWNSPOUT ASSEMBLIES SHALL THE OWNER'S CONSTRUCTION REPRESENTATIVE PRIOR TO "STRUCTURAL' WELDING CODE". ELECTRODES SHALL CONFORM 'E70XX. ALUMINUM 5 x 0.032" "K" -SME GUTTER ASSEMBLY 'w/ PLACEMENT OF CONCRETE. THE REVIEW SHALL CONFORM TO TO AWS 5.5, MITERS, HANGERS, END CAPS, ELBOWS, OULET SECTIONS, THE REQUIREMENTS OF CHAPTER 17 OF THE NORTH SPLASHBLOCKS & ALL OTHER ACCESSORIES TO INSTALL A CAROLINA STATE BUILDING CODE. 8.3 ANCHOR BOLTS SHALL BE ASTM F1554 AND EITHER COMPLETE SYSTEM TO CATCH THE WATER FROM THE ROOF & HEADED OR HOOKED AS REQUIRED BY THE DRAWINGS. CARRY TO GROUND WHERE WATER CAN SHEET FLOW AWAY 4.4 FABRICATE CONTINUOUS BARS IN FOUNDATIONS TO THE PROVIDE NUT' AND WASHER ASSEMBLIES WITH EACH ANCHOR FROM THE FACILITY/BUILDING. LONGEST PRACTICABLE LENGTHS. BOLT UNLESS NOTED OTHERWISE. 4.5 REINFORCING STEEL SHALL NOT BE BENT AFTER BEING 8.4 SPLICING OF STRUCTURAL STEEL MEMBERS 1S PROHIBITED 13.6 CAULK & SEALANT MATERIAL SHALL BE SONNEBORN "NP PARTIALLY EMBEDDED IN HARDENED CONCRETE. WITHOUT THE APPROVAL OF THE STRUCTURAL ENGINEER, AS SONOLAS11C 1" ONE COMPONENT, MOISTURE CURING TO LOCATION AND TYPE OF SPLICE. ANY MEMBER HAVING A HIGH PERFORMANCE POLY -URETHANE SEALANT, OR AN 4.6 BARS SHALL BE COLD BENT AND SHALL NOT BE HEATED SPLICE NOT SHOWN AND DETAILED ON THE SHOP DRAWINGS APPROVED EQUAL. FOR ANY REASON. WILL BE REPLACED. 13.7 ALL CANOPY FASTENERS FOR ROOF & WALL PANELS 4.7 REINFORCING BARS SHALL NOT BE WELDED UNLESS 8.5 ALL HOLES IN STRUCTURAL STEEL ARE TO BE PUNCHED SHALLE BE STAINLESS STEEL U.N.O.. NOTED OTHERWISE ON THE DRAWINGS. OR DRILLED. FLAME CUTTING OF STEEL IS STRICTLY PROHIBITED. 4.8 IT IS ACCEPTABLE TO LAP REINFORCING STEEL IN CONCRETE A MINIMUM 50 BAR DIAMETERS, UNLESS NOTED 8.6 ALL DESIGN, DETAILING, FABRICATION AND ERECTION OTHERWISE ON THE DRAWINGS. SHALL BE IN ACCORDANCE WITH THE LATEST EDITION OF THE AMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISC) 4.9 LAP SPLICED BARS IN CONCRETE ARE TO BE WIRE TIED. MANUAL OF STEEL CONSTRUCTION. 5.0 CONCRETE 8.7 STRUCTURAL STEEL ERECTION SHALL BE REVIEWED BY THE OWNER'S CONSTRUCTION REPRESENTATIVE. THE REVIEW 5.1 IN GENERAL CONCRETE SHALL DEVELOP 4,000 psi SHALL CONFORM TO THE REQUIREMENTS OF CHAPTER 17 OF MINIMUM COMPRESSIVE STRENGTH AT 28 DAYS. IN ADDITION THE NORTH CAROLINA STATE BUILDING CODE. - THE CONCRETE MIX WORK SHALL INCLUDE THE FOLLOWING: a.) CEMENT MATERIAL SUPPLIED SHALL BE TYPE I OR 8.8 FABRICATOR/CONTRACTOR SHALL SUBMIT SHOP TYPE 11 PORTLAND CEMENT THAT IS IN DRAWINGS FOR OWNER/ENGINEER APPROVAL PRIOR TO CONFORMANCE w/ ASTM C150. FABRICATION.( ALL SHOP DRAWINGS MAY BE EXPEDITED IF b.) FLY ASH THAT IS IN CONFORMANCE w/ ASTM C618, THE FABRICATOR ADHERES CLOSELY TO THE DETAILS, NOTES, CLASS F MAY BE INCLUDED IN THE MIX FLY ASH AND INSTRUCTIONS SHOWN ON THE DRAWINGS DESIGN LOADS: 14.0 ABBREVIATIONS LIVE LOAD: 100 PSF (PLATFORMS), 1.0 k HOIST 14.1 THE FOLLOWING LIST OF ABBREVIATIONS IS NOT ROOF: 20 PSF INTENDED TO REPRESENT ALL THOSE USED ON THE SNOW: 10 PSF (GROUND), IMPORTANCE FACTOR (is): 1.10 DRAWINGS, BUT TO SUPPLEMENT THE MORE COMMON WIND: ZONE: 160 mi/hr, EXPOSURE C, CATEGORY III, IMPORTANCE FACTOR (Iw): 1.15 ABBREVIATIONS USED. ADD'L = ADDITIONAL JT. = JOINT NORTH CAROLINA STATE BUILDING CODE (NCSBC) 2018 (INTERNATIONAL BUILDING CODE (IBC) BD. = BOARD L.P. = LOW POINT 2015 w/ NC AMENDMENTS) & ASCE 7-10 WIND & SEISMIC DESIGN: BLDG. = BUILDING MAS. = MASONRY BM. = BEAM MAT'L. = MATERIAL CALCULATED WIND BASE SHEARS: Vx = 27.2 k & Vy = 10.0 k B.O. = BOTTOM OF MAX. = MAXIMUM BRG. = BEARING MFG. = MANUFACTURER COMPONENTS & CLADDING WIND PRESSURES: BTM. = BOTTOM MIN. = MINIMUM ROOF: ZONE 1 = PSF & - PSF C.I.P. = CAST -IN-PLACE M.O. = MAS. OPNG. ZONE 2 = PSF & - PSF CLR. = CLEAR MTL. = METAL ZONE 3 = PSF & - PSF CMU = CONC. MAS. UNIT N.S. = NEAR SIDE WALLS: ZONE 4 = PSF & - PSF CONC. = CONCRETE N.T.S. = NOT TO SCALE ZONE 5 = PSF & - PSF CONN. = CONNECTION O.C. = ON CENTER CONST. = CONSTRUCTION 0/F OUTSIDE FACE SEISMIC: CONT. = CONTINUOUS OPNG. OPENING SEISMIC DESIGN PARAMETERS: COORD. = COORDINATE OPP. = OPPOSITE RESPONSE MODIFICATION COEFFICIENT R = 3 CTR. = CENTER ORIENT: ORIENTATION SPECTRAL RESPONSE ACCELERATION.............SHORT PERIOD S(DS) = 23.9 CTR D. = CENTERED PLCS. = PLACES SPECTRAL RESPONSE ACCELERATION ....... I SECOND PERIOD S(D1) = 14.9% DIM. = DIMENSION REF. = REFERENCE SEISMIC OCCUPANCY CATEGORY .......................................... = III DIM.'s = DIMENSIONS REINF. = REINFORCING SITE CLASS.......................................................................... = D DIR. DIRECTION = REINFORCED SEISMIC DESIGN CATEGORY .................................................. SDC = C D.S. = DOWN SPOUT REQ'D. = REQUIRED IMPORTANCE FACTOR............................................................ le = 1.25 DWG. = DRAWING REQ.'s = REQUIREMENTS DWG.'s = DRAWINGS ROT. = ROTATE BASIC STRUCTURAL SYSTEM - EA. = EACH SIM. = SIMILAR EL = ELEVATION SPA. = SPACED "OTHER" SELF SUPPORTING STRUCTURE SIM. TO BUILDING's E.O. = EDGE OF SQ. = SQUARE EQ. = EQUAL STD. = STANDARD ANALYSIS PROCEDURE = EQUIVALENT LATERAL FORCE EQUIP. = EQUIPMENT STL. = STEEL EXIST. = EXISTING SUPPT. = SUPPORT SEISMIC BASE SHEAR = Vx = ? k Vy = ? k EXP. = EXPANSION T&B = TOP & BOTTOM EXTR. = EXTERIOR T/D = TURN DOWN ARCHITECTURAL, MECHANICAL COMPONENTS ANCHORED? N/A FDN. = FOUNDATION THK. = THICK F.S. = FAR SIDE THK'D = THICKENED FIELD TEST (SOIL BEARING PER PROJECT GEOTECH REPORT) = REF. STRUCTURAL NOTE 3.1 FT. = FEET T.O. = TOP OF FTG. = FOOTING T.O.S = TOP OF STEEL (NOT APPLICABLE) HO ZD = HORIZONTAL U.N.O. = TYPICAL NOTED DESIGN CRITERIA: H.P. = HIGH POINT OTHERWISE I/F = INSIDE FACE VERT. = VERTICAL CONCRETE 28 DAY COMPRESSIVE STRENGTH: INFO. = INFORMATION W.P. = WORK POINT MISC. CONCRETE: REF. STRUCTURAL 'NOTE 5.1 INTR. = INTERIOR REINFORCING STEEL: ASTM A615, GRADE 60 WELDED WIRE FABRIC: NOT APPLICABLE STRUCTURAL STEEL: REF. STRUCTURAL NOTE 8.1 (NOT APPLICABLE) ALUMINUM: REF. STRUCTURAL NOTE 9.1 BOLTS SHALL BE 3/4"0 ASTM A325: NOT APPLICABLE ANCHOR BOLTS SHALL BE 3/4.0 ASTM F1554 REF. STRUCTURAL NOTE 8.3 STEEL ELECTRODES SHALL CONFORM TO: AWS 5.5 E70XX ALUMINUM WELD FILLERS ALLOYS SHALL CONFORM TO: AWS A5.10 SOIL BEARING CAPACITY- REF. STRUCTURAL NOTE 3.1 (NOT APPLICABLE) LEGEND: ENLARGED PLAN AREA, DETAIL CONC. SLAB, ETC. CONC. CMU CLOCK (NOT APPLICABLE) BRICK rZ (NOT APPLICABLE) GROUT DETAIL OR SECTION j NUMBER/SHOWN ON SHEET = N PROJECT NORTH 40 NORTH ELEVATION DATUM ELEVATION NUMBER/SHOWN = ON SHEET X.S-Y ELEVATIONS X' -X" (Y.YY') - X' -X" = DISTANCE TO/FROM FACILITY REFERENCE EL 0'-0" Y.YY' = EQUIVALENT SITE EL VERTICAL DATUM N SHALL BE USED AS A PARTIAL CEMENT REPLACEMENT & NOT EXCEED 25% OF THE TOTAL 8.9 ALL GALVANIZED MATERIALS THAT ARE FIELD CUT, FIELD ! CEMENTITIOUS CONTENT. WELDED OR DAMAGED IN SURFACE FINISH SHALL BE C.) AGGREGATE SHALL BE "NORMAL" WEIGHT THAT IS IN CLEANED AND RE -COATED w/ A 95% ZINC RICH OXIDE i' CONFORMANCE w/ ASTM C33. PAINT. d.) WATER SHALL BE IN CONFORMANCE w/ ASTM C94. e.) AIR ENTRAINING ADMIXTURE IS ALLOWED PROVIDED 2 IT IS IN CONFORMANCE w/ ASTM C260. THE TOTAL REV: AIR CONTENT REQUIRED IS 5% f 17o. cm f.) WATER REDUCING ADMIXTURE IS ALLOWED PROVIDED o IT IS IN CONFORMANCE w/ ASTM C494, TYPE A OR D. N g.) MAXIMUM SLUMP = 3" w/OUT WATER REDUCING�ED Cape Fear ADMIXTURE & 6" w/ A WATER REDUCING '� n ADMIXTURE. 243 NORTH FRONT STREET Public Utility AuthoritY WILMINGTON NORTH CAROLINA 28401 Stewardship. Sustainablility. Service. N h.) WATER/CEMENT RATIO (w/c) = 0.45 MAXIMUM. TELE: (910) 343-1048 FAX: (910) 251-8282 LICENSE: F-1222 ESCRIPTION DATE: STRUCTURAL GENERAL NOTES, DESIGN LOADS, DESIGN CRITERIA & LEGEND � ii.fUi t� I� M PUBLIC UTILITY AUTHORITY SOUTHSI DE WWTP UV DISINFECTION SYSTE CAPE FEAR PUBLIC UTILITY AUTHORITY 235 GOVERNMENT CENTER DRIVE WILMINGTON, NC 28403 OFFICE: (910)332-6560 DATE: JUNE 2018 SCALE: AS NOTED DRAWN BY: WF13 CHECKED BY: AWB PROJECT N0. 7123-0002 SHEET NO: S-1 cn 1 [O/F EXIST. WA L TO F EXIST. WALL] ` 1 n \ l [ I /F L TO I LL] TYP. 54'-0"(*) 61'-0"(*) 10'-11 "(*) 10'-10"(*) 10'-10"(*) 10'-10"(*) 7' 11-(*) 14'-11 "(*) 10'-8"(*) ^-8"(*) s s 0"(*) '-11" s --- ss ss --__ SS - SS - Ss ---_ - — SS S SS SS ss S �'� �_ SS SS_ 8"(*) 7'-0" 7'-11t [TYP. U.N.O.] (*) (*) 5'-11 1/2- 1'-0"(*) 5'-0" it—on *)' T.O. EXIST. ONC. WALL (TYP.) IrEL 0'-0 (9. 0')[*] [REF. NOTE 1 - TYP. U.N.O.] a S o�00 6 5 -0 LONG BARS. VENDORS) EXPERIENCED IN MANUFACTURING THE ASSEMBLIES REQUIRED. GRATING ASSEMBLIES ARE I -g ; �' N J J Q 3 O Q 3 0/F EXIST. "OR INAL CONSTR." C.I.P. EXISTING C.I.P. REINF. CONCRETE EXTERIOR 9. REFERENCE DWG. S-1 FOR ADDITIONAL GENERAL NOTES, MATERIAL 0/F EXIST. "EXPANSION CONSTR.- C.I.P. �-_e- RECTANGULAR BANDING BARS ALONG PERIMETERS INCLUDED ORIGINAL CONSTRUCTION IN 1971 W — REINF. CONC. E TR. WALLS (TYP.) .-. \ \ 04 d 00 4. RECORD r INDICATED THE "ORIGINAL" EXISTING C.I.P. REINF. CONCRETE EXTERIOR WALL [REF. NOTE 4] #5 DOWELS FROM THE EXISTING BASE SLAB SPA. N " EXTR. WALL PANEL ® PERIMETER OF I I . v a O I EXTR. WALL PANEL ® PERIMETER OF REINF. CONC. EXTR. WALLS (TYP.) CANOPY ENCLOSURE (TYP. 3 SIDES) i I G1 i I G1' M r N SLAB SPA. ® 4j" O.C. EACH FACE. c.) #5 HORIZONTAL BARS SPA. ® 1'-0" O.C. CTR'D IN THE WALL. E.O. EXIST. "ORIGIN L CONSTR." C.I.P. N 0 °' L ;Zo�� b.) #4 VERTICAL BARS 5-0" LONG SPA. 0 V-6" O.C. EACH FACE. 8. q 3 £ r-, [REF. NOTE 51 - AL AL CS8 WIND GIRTS (TYP.) ,� s` i [REF. NOTE 6] BEARING \5 �, CS8 i i ( i [REF. SECTIONS &DETAILS] W a N Cfl a Cn 5 1/2 e-- --- -._. ,.�. _- I i I \ o G1 E.O. EXIST. C.I.P. REINF. 4L I12x11.67 COL. of o - _ _� - - -__ -_- - - -� I \ TYP. 8 PLCS.) v AL N o (TYP. 2 PLCS.)="(*)_ -� I S8 5 0"( - - _ _ T.O. EXIST. CONC. WALL "MOD " , M " REF.NOTE 8 EL 0 -6 (10.40 ) os o i I i (TYP-) .. iE [TYP. U.N.O.] - i a CL v to N ~W'Cq (OD 1 - PLAN - EXIST. FACILITY TOP & UV MODIFICATIONS LAYOUT I O W P9�, TOP PLAN NOTES: SCALE: 1/8" = OOi E.O. EXIST. EXPANSION CONSTR." C.I.P. " �^ NORTH U c O ; p - O 'O a � �'� 1. REFERENCE ELEVATION FOR THE EXISTING CHLORINE CONTACT TANK J I I 8 CTD. ... NOTE THE FOLLOWING: REINF. CONC. INTR. WALLS (TYP.) m" T.O. CONIC. EL 0 -0 = EL 9 '- 10� (9.90 )[*] N.A.V.D.-88. REFERENCE CIVIL DWG.'s FOR CONSTRUCTION INCLUDED THE FOLLOWING: i ! I �?, !! N x a.) #4 DOWELS FROM THE EXISTING BASE SLAB SPA. 0 12" O.C. CTR'D IN '' THE WALL. SERIES SPACE PROFILE. "._ o'm 2. IN GENERAL THE EXISTING GRADE AROUND THE FACILITY IS -1'-0(8.90')[*]. m b.) #3 VERTICAL BARS SPA. ® 1'-0" O.C. CTR'D IN THE WALL. b.) GRATING "G2"' = 2j" HEAVY DUTY ALUMINUM PLANK w/ A DIAGONAL PUNCH PATTERN FOR N i I ✓.'.'..' ./ c.) #4 HORIZONTAL BARS SPA. ® 1'-0" O.C. CTR'D IN THE WALL. [REF. NOTE 7] v i I j cO X I /\ i I i AL N ^ J CS8 J - j 0 3 J 3 a of AL I12x11.67 COL. j G1 ¢ i 1 (TYP. 8 PLCS.) ( / / ov~i AL i /�l N /\ WCS8 W -'. J a �,. _ REF. NOTE 8 f i a I G2 �o o ~ �o I o N O J O O J 00 M u �... i — C5 O N Q 3 Q 3 .*. i ao a ao 00 a C14 € 04 rn x 5-< (n O - to W W d I J O® O m D_ a- o i o N i i � W i i g I i 00 , U O a a I [Q 1 /1 a I �`� °� Et 1 O o� �' n m N 1L } fill -CS& 1 a j– ---+ U_ z M S o�00 6 5 -0 LONG BARS. VENDORS) EXPERIENCED IN MANUFACTURING THE ASSEMBLIES REQUIRED. GRATING ASSEMBLIES ARE I -g ; �' N J J Q 3 O Q 3 0/F EXIST. "OR INAL CONSTR." C.I.P. EXISTING C.I.P. REINF. CONCRETE EXTERIOR 9. REFERENCE DWG. S-1 FOR ADDITIONAL GENERAL NOTES, MATERIAL N �-_e- RECTANGULAR BANDING BARS ALONG PERIMETERS INCLUDED ORIGINAL CONSTRUCTION IN 1971 W — REINF. CONC. E TR. WALLS (TYP.) .-. \ \ 04 d 00 4. RECORD r INDICATED THE "ORIGINAL" EXISTING C.I.P. REINF. CONCRETE EXTERIOR WALL [REF. NOTE 4] #5 DOWELS FROM THE EXISTING BASE SLAB SPA. N " EXTR. WALL PANEL ® PERIMETER OF I I o o v a O I EXTR. WALL PANEL ® PERIMETER OF Q) CANOPY ENCLOSURE (TYP. 3 SIDES) i I G1 i I G1' M r N SLAB SPA. ® 4j" O.C. EACH FACE. c.) #5 HORIZONTAL BARS SPA. ® 1'-0" O.C. CTR'D IN THE WALL. E.O. EXIST. "ORIGIN L CONSTR." C.I.P. N 0 °' L ;Zo�� b.) #4 VERTICAL BARS 5-0" LONG SPA. 0 V-6" O.C. EACH FACE. 8. q 3 £ REINF. CONC. INTR. WALLS (TYP.) \ ( - AL AL CS8 WIND GIRTS (TYP.) ,� s` i [REF. NOTE 6] BEARING \5 �, CS8 i i ( i [REF. SECTIONS &DETAILS] W a N Cfl a Cn 5 1/2 e-- --- -._. ,.�. _- I i I \ o G1 E.O. EXIST. C.I.P. REINF. 4L I12x11.67 COL. of (TYP. - _ _� - - -__ -_- - - -� I \ TYP. 8 PLCS.) v AL N o (TYP. 2 PLCS.)="(*)_ -� I S8 5 0"( - - _ _ T.O. EXIST. CONC. WALL "MOD " , M _ REF.NOTE 8 EL 0 -6 (10.40 ) os o i I i (TYP-) .. iE [TYP. U.N.O.] �� o o M Na a CL v to N ~W'Cq (OD 1 - PLAN - EXIST. FACILITY TOP & UV MODIFICATIONS LAYOUT I O W P9�, TOP PLAN NOTES: SCALE: 1/8" = OOi I I �^ NORTH U c O ; p - O 'O a � �'� 1. REFERENCE ELEVATION FOR THE EXISTING CHLORINE CONTACT TANK J I I 8 CTD. ... NOTE THE FOLLOWING: h m" T.O. CONIC. EL 0 -0 = EL 9 '- 10� (9.90 )[*] N.A.V.D.-88. REFERENCE CIVIL DWG.'s FOR CONSTRUCTION INCLUDED THE FOLLOWING: i ! I �?, !! N COORDINATING VERTICAL DATUM ELEVATIONS INDICATED AS REQUIRED & ADDITIONAL INFORMATION. a.) #4 DOWELS FROM THE EXISTING BASE SLAB SPA. 0 12" O.C. CTR'D IN '' THE WALL. SERIES SPACE PROFILE. "._ o'm 2. IN GENERAL THE EXISTING GRADE AROUND THE FACILITY IS -1'-0(8.90')[*]. FIELD VERIFY & b.) #3 VERTICAL BARS SPA. ® 1'-0" O.C. CTR'D IN THE WALL. b.) GRATING "G2"' = 2j" HEAVY DUTY ALUMINUM PLANK w/ A DIAGONAL PUNCH PATTERN FOR N i I ✓.'.'..' ./ c.) #4 HORIZONTAL BARS SPA. ® 1'-0" O.C. CTR'D IN THE WALL. SLIP RESISTANCE. v i I QI I /\ i I i _ S o�00 6 5 -0 LONG BARS. VENDORS) EXPERIENCED IN MANUFACTURING THE ASSEMBLIES REQUIRED. GRATING ASSEMBLIES ARE I -g ; �' N J J Q 3 O Q 3 I EXISTING C.I.P. REINF. CONCRETE EXTERIOR 9. REFERENCE DWG. S-1 FOR ADDITIONAL GENERAL NOTES, MATERIAL N �-_e- RECTANGULAR BANDING BARS ALONG PERIMETERS INCLUDED ORIGINAL CONSTRUCTION IN 1971 W — W \ \ S o�00 6 5 -0 LONG BARS. VENDORS) EXPERIENCED IN MANUFACTURING THE ASSEMBLIES REQUIRED. GRATING ASSEMBLIES ARE I -g ; �' d.) 3. RECORD DWG. s REVIEWED V T_ DWG.'s REVIEWED INDICATED THE "EXPANSION" EXISTING C.I.P. REINF. CONCRETE EXTERIOR 9. REFERENCE DWG. S-1 FOR ADDITIONAL GENERAL NOTES, MATERIAL #4 �-_e- RECTANGULAR BANDING BARS ALONG PERIMETERS INCLUDED ORIGINAL CONSTRUCTION IN 1971 & ADDITIONAL EXPANSION CONSTRUCTION IN 1986. — CONSTRUCTION INCLUDED THE FOLLOWING: SPECIFICATION INFORMATION & REQUIREMENTS. 3 i 04 d 00 4. RECORD r INDICATED THE "ORIGINAL" EXISTING C.I.P. REINF. CONCRETE EXTERIOR WALL a.) #5 DOWELS FROM THE EXISTING BASE SLAB SPA. N " EXTR. WALL PANEL ® PERIMETER OF I I o o i EXTR. WALL PANEL ® PERIMETER OF Q) CANOPY ENCLOSURE (TYP. 3 SIDES) i I G1 i I G1' CANOPY ENCLOSURE (TYP. 3 SIDES) N SLAB SPA. ® 4j" O.C. EACH FACE. c.) #5 HORIZONTAL BARS SPA. ® 1'-0" O.C. CTR'D IN THE WALL. N 0 °' L ;Zo�� b.) #4 VERTICAL BARS 5-0" LONG SPA. 0 V-6" O.C. EACH FACE. 8. q 3 £ AL CS8 WIND GIRTS (TYP.) \ ( EXIST. CHLORINE CONTACT TANK i i I i AL CS8 WIND GIRTS (TYP.) ,� s` i [REF. SECTIONS & DETAILS] BEARING \5 �, FACILITY (REF. NOTE 3) " i i ( i [REF. SECTIONS &DETAILS] W a N 5 1/2 e-- --- -._. ,.�. _- I i X o �i o E.O. EXIST. C.I.P. REINF. (TYP. - _ _� - - -__ -_- - - -� CONIC. WEIR WALL BELOW N o (TYP. 2 PLCS.)="(*)_ -� - -- _- ._ . _ 5 0"( - - _ _ T.O. EXIST. CONC. WALL "MOD " , M _ EL 0 -6 (10.40 ) os o -.._ - ._ - .� [TYP. U.N.O.] �� o o M Na EXPANSION CONSTRUCTION ORIGINA CONSTRUCTION CL v to N ~W'Cq 1 - PLAN - EXIST. FACILITY TOP & UV MODIFICATIONS LAYOUT O W P9�, TOP PLAN NOTES: SCALE: 1/8" = 1'-0" a3- .. NORTH c O ; p - O 'O a � �'� 1. REFERENCE ELEVATION FOR THE EXISTING CHLORINE CONTACT TANK FACILITY IS THE EXISTING WALL 6. RECORD DWG.'s REVIEWED INDICATED THE "ORIGINAL" EXISTING C.I.P. REINF. CONCRETE INTERIOR WALL 8 CTD. ... NOTE THE FOLLOWING: m" T.O. CONIC. EL 0 -0 = EL 9 '- 10� (9.90 )[*] N.A.V.D.-88. REFERENCE CIVIL DWG.'s FOR CONSTRUCTION INCLUDED THE FOLLOWING: a.) GRATING Gi " = 21" x A" LIGHT DUTY ALUMINUM IN ACCORDANCE w/ MFG.'S 19-4 "w" COORDINATING VERTICAL DATUM ELEVATIONS INDICATED AS REQUIRED & ADDITIONAL INFORMATION. a.) #4 DOWELS FROM THE EXISTING BASE SLAB SPA. 0 12" O.C. CTR'D IN '' THE WALL. SERIES SPACE PROFILE. "._ o'm 2. IN GENERAL THE EXISTING GRADE AROUND THE FACILITY IS -1'-0(8.90')[*]. FIELD VERIFY & b.) #3 VERTICAL BARS SPA. ® 1'-0" O.C. CTR'D IN THE WALL. b.) GRATING "G2"' = 2j" HEAVY DUTY ALUMINUM PLANK w/ A DIAGONAL PUNCH PATTERN FOR COORDINATE w/ CIVIL DWG.'s AS REQUIRED. c.) #4 HORIZONTAL BARS SPA. ® 1'-0" O.C. CTR'D IN THE WALL. SLIP RESISTANCE. S o�00 6 5 -0 LONG BARS. VENDORS) EXPERIENCED IN MANUFACTURING THE ASSEMBLIES REQUIRED. GRATING ASSEMBLIES ARE I -g ; �' d.) 3. RECORD DWG. s REVIEWED INDICATED THE EXISTING CHLORINE CONTACT TANK FACILITY CONSTRUCTION 7. RECORD DWG.'s REVIEWED INDICATED THE "EXPANSION" EXISTING C.I.P. REINF. CONCRETE EXTERIOR 9. REFERENCE DWG. S-1 FOR ADDITIONAL GENERAL NOTES, MATERIAL #4 P-0:2, RECTANGULAR BANDING BARS ALONG PERIMETERS INCLUDED ORIGINAL CONSTRUCTION IN 1971 & ADDITIONAL EXPANSION CONSTRUCTION IN 1986. WALL CONSTRUCTION INCLUDED THE FOLLOWING: SPECIFICATION INFORMATION & REQUIREMENTS. 3 i 5. RECORD 4. RECORD DWG.'s REVIEWED INDICATED THE "ORIGINAL" EXISTING C.I.P. REINF. CONCRETE EXTERIOR WALL a.) #5 DOWELS FROM THE EXISTING BASE SLAB SPA. 1'-0" O.C. CTR'D IN THE WALL. o o m� M o a.) CONSTRUCTION INCLUDED THE FOLLOWING: b.) #5 VERTICAL BARS SPA. ®1'-0° O.C. CTR'D IN THE WALL. #4 o%- a.) #4 DOWELS FROM THE EXISTING BASE SLAB SPA. ® 4j" O.C. EACH FACE. c.) #5 HORIZONTAL BARS SPA. ® 1'-0" O.C. CTR'D IN THE WALL. N 0 °' L ;Zo�� b.) #4 VERTICAL BARS 5-0" LONG SPA. 0 V-6" O.C. EACH FACE. 8. SYMBOL ON PLANS INDICATES THE SPAN DIRECTION OF THE GRATING ASSEMBLIES MAIN N o c.) #4 f VERTICAL BARS " T-2" LONG SPA. ®1'-6" O.C. EACH FACE INTERMITTENTLY BETWEEN THE BEARING BARS. IN GENERAL GRATING ASSEMBLIES ARE TO BE MANUFACTURED BY REPUTABLE S o�00 6 5 -0 LONG BARS. VENDORS) EXPERIENCED IN MANUFACTURING THE ASSEMBLIES REQUIRED. GRATING ASSEMBLIES ARE I -g ; �' d.) #4 HORIZONTAL BARS SPA. ® 1'-0" O.C. EACH FACE. TO INCLUDE RECTANGULAR MAIN BEARING BARS, RECTANGULAR CROSS BARS OR RODS, AND - °' 1-4 o e.) #4 HORIZONTAL CORNER BARS SPA. ®1'-0" O.C. EA. FACE, SPLICED w/ THE HORIZONTAL BARS RECTANGULAR BANDING BARS ALONG PERIMETERS o o & FABRICATED w/ 2'-6" LONG LEGS. OF PANELS & AT OPENINGS. REFERENCE PROJECT oi� Q0 5. RECORD DWG.'s REVIEWED INDICATED THE "EXPANSION" EXISTING C.I.P. REINF. CONCRETE EXTERIOR SPECIFICATIONS, PLANS, SECTIONS & DETAILS FOR 212 WALL CONSTRUCTION INCLUDED THE FOLLOWING: ADDITIONAL INFORMATION & REQUIREMENTS. REV: DESCRIPTION DATE-.*" o o m� M o a.) #4 DOWELS FROM THE EXISTING BASE SLAB SPA. ®4" O.C. EACH FACE. Y 0 0 ^ N b.) #4 VERTICAL BARS SPA. ®8" O.C. EACH FACE.; t '- Q og� c.) #5 HORIZONTAL BARS SPA. 0 1'-0" O.C. EACH FACE. SEAL "0 d.) #? HORIZONTAL CORNER BARS SPA. 0 1'-0" O.C. EA. FACE, SPLICED w/ THE HORIZONTAL BARS 1W SEVIOrk of ED k 1=N" H Cape Fear 24995 S o & FABRICATED w/ ? -? LONG LEGS. '� k; 4 =N > 243 NORTH FRONT STREETPublic' Utility Authority WILMINGTON, NORTH CAROLINA 28401 Stewardship. Sustafnab(Ifity. Service. `"`"•"`' P..A o W 0 N TELE: (910) 343-1048 'Fx,,A�M„F;t 0 ;1�,IS �N % FAX: (910) 251-8282 � X o LICENSE: F-1222 CAPE FEAR PUBLIC UTILITY AUTHORITY SOUTHSIDE WWTP UV DISINFECTION SYSTEM CAPE FEAR PUBLIC UTILITY AUTHORITY 235 GOVERNMENT CENTER DRIVE WILMINGTON, NC 28403 OFFICE: (910)332-6560 el DATE: JUNE 2018 SCALE: AS NOTED DRAWN BY: WFB CHECKED BY: AWB PROJECT NO.: 7123-0002 r- __ SHEET NO: S-2 M x a N D a U i N O O O I M N n 'n K Q x2 13'-7" STANDING SEAM PROFILE MTL. ROOF PANELS (SL.) r � o AL I80.02 ROOF B Ln 'n (REF. PLAI AL PLANK GRATING (REF. PLAN) 0'-6" (10.40') F. PLAN] EXIST. CONC. WALL 0'-0" (9.90')[*] ST. 1'-0" & 8" WALLS] F. PLAN] FIN. GRADE EF. CIVIL DWG.'s & FIELD COORD. AS REQ'D) EXIST. C.I.P. REINF. CONC.- EXTR. WALL 1'-0"(*) 1 [REF. PLAN] ■ ' I [REF. PI 00 f I ,i T.O. EXIST. CONC. SLABX T C T.O. E IS . CONC. SLAB EL -7'-6" (2.40')[*] EL -7'-6" (2.40')[*] Go0 N ■ ■ ■ 5'-0" 13'-7" (REF. PLAN) r W.P. W.P. 5'-0" 12 AL CS6 PURLINS SPA. 2'-0" O.C. (MAX.) [TYP.] T.O. AL BM. EL 12'-0" (21.90') [REF. PLAN] AL I8x7.02 ROOF BM. (SL.) r [REF. PLAN] r / cV DBL. AL L3x3xj KNEE BRACE ASSEMBLIES I (CTR'D ON COL.'s) [TYP.] W.P. AL I8x7.02 ROOF BM. _ (REF. PLAN) W.P. AL CS8 WALL GIRTS SPA. ® 4'-0" O.C. (MAX.) AL I12x11.67 COL. AL I12x11.67 COL. [TYP. U.N.O.] (REF. PLAN) (REF. PLAN) EXTR. MTL. WALL PANELS I (TYP-) o.. r ao ' AL CS12x8.27 (TYP.) e A' [SPAN BTWN. COL.'s] C.I.P. REINF. CONC. PED. • (REF. DETAIL ?.S-5) STANDING SEAM PROFILE MTL. (REF. PLAN) .x. ROOF PANELS (SL.) AL CS6 PURLINS SPA. v r 2'-0" O.C. (MAX.) a o [TYP.] _N 0 A 3 12 W a v o T.O. ,AL BM. ° EL 12'-0" (21.90') [REF. PLAN] 0 r 4 AL I8.02 ROOF BM. (SL.) M [REF. PLAN] r 0 AL I8.02 ROOF BM. N (REF. PLAN) 00 AL I8.02 ROOF BM. o (REF. PLAN) 0 N EXTR. MTL. WALL PANELS S ( (rn'') o 4.S-4 ; AL CS8 WALL GIRTS SPA. AL GRATING ® 4'-0" O.C. (MAX.) (REF. PLAN) [TYP. U.N.O.] W Q ja T.O. CONC. MOD AL GRATING T.O. EL 0'-6" (10.40') 5.S-4 EL [REF. PLAN] �■■ ■' �■■�■■�■■�■■I �■■ ■�a� [RE m 7 y co T.O. EXIST. CONC. WALL o. ■ T.O. N EL 0'-0" (9.90')[*] ■ ■ o EL D [EXIST. 1'-0" & 8" WALLS] ' I[EXT N [REF. PLAN] o >./\ 1. f, f, a ' in p oo. ( i. @ [REo ■6 ■■ ! tco FIN. GRADE . I . • , AL CS12x8.27 (TYP.) a (REF. CIVIL DWG.'s & FIELD LEI a �. ■'r ■ ■ ■ ■' [SPAN BT4VN. COL.'s] (R i X COORD. AS REQ D) I FILL SPACE w/ SAND 0 EXIST. C.I.P. REINF. CONC. E ° C.I.P. REINF. CONC. PED. N EXTR. WALL 3.S-4 I ( BEYOND [REF. NOTE 11 r. STANDING SEAM PROFILE MTL. ROOF PANELS (SL.) r � o AL I80.02 ROOF B Ln 'n (REF. PLAI AL PLANK GRATING (REF. PLAN) 0'-6" (10.40') F. PLAN] EXIST. CONC. WALL 0'-0" (9.90')[*] ST. 1'-0" & 8" WALLS] F. PLAN] FIN. GRADE EF. CIVIL DWG.'s & FIELD COORD. AS REQ'D) EXIST. C.I.P. REINF. CONC.- EXTR. WALL 1'-0"(*) 1 [REF. PLAN] ■ ' I [REF. PI 00 f I ,i T.O. EXIST. CONC. SLABX T C T.O. E IS . CONC. SLAB EL -7'-6" (2.40')[*] EL -7'-6" (2.40')[*] Go0 N ■ ■ ■ 5'-0" 13'-7" (REF. PLAN) r W.P. W.P. 5'-0" 12 AL CS6 PURLINS SPA. 2'-0" O.C. (MAX.) [TYP.] T.O. AL BM. EL 12'-0" (21.90') [REF. PLAN] AL I8x7.02 ROOF BM. (SL.) r [REF. PLAN] r / cV DBL. AL L3x3xj KNEE BRACE ASSEMBLIES I (CTR'D ON COL.'s) [TYP.] W.P. AL I8x7.02 ROOF BM. _ (REF. PLAN) W.P. AL CS8 WALL GIRTS SPA. ® 4'-0" O.C. (MAX.) AL I12x11.67 COL. AL I12x11.67 COL. [TYP. U.N.O.] (REF. PLAN) (REF. PLAN) EXTR. MTL. WALL PANELS I (TYP-) o.. r ao ' AL CS12x8.27 (TYP.) e A' [SPAN BTWN. COL.'s] C.I.P. REINF. CONC. PED. • (REF. DETAIL ?.S-5) o EXIST. C.I.P. REINF. CONC. EXIST. C.I.P. REINF. CONC. M STM. SLAB 1'-0"(*) 5'-5 1/2- '_0 4'-5 1/2- 8"(*) BTM. SLAB 1'-0"(*) 5'-5 1/2- '-0 4'-5 1/2- 8"(*) o [REF. PLAN] (REF. PLAN) [REF. PLAN] [REF. PLAN] (REF. PLAN) [REF. PLAN] N 1 - SECTION - THRU UV MOD & CANOPY FRAMING 2 - SECTION - THRU UV MOD & CANOPY FRAMING co m M SCALE: 3/8" = 1'-0" SCALE: 3/8" = 1'-0" x fi N 1'-0" (2) CONT. #4 HORZ. BARS N) (2) CONT. . #4 HORZBARS TYP#3 DWL.'s w/ 90' HOOKS (REF. NOTE 3) ( . (HOOKS SHOWN OFFSET FOR CLARITY) M 2" CLR. (REF. NOTE 3) #3 DWL.'s w/ 90' HOOKS " [REF. NOTE 31 N #4 BARS SPA. ®8 O.C. (TYP.) CONT." CHAMFER (HOOKS SHOWN OFFSET FOR 'CLARITY) EA. WAY (® MID -DEPTH) T.O. CONC. MOD/AL GRATING X T.O. CONC. MOD AL GRATING [REF. NOTE 3] EL 0'-6" (10.40') EL 0'-6" (10.40AL BAR GRATING [REF. PLAN] ') N [REF. PLAN] a AL BAR GRATING itCIOT.O. EXIST. CONC. WALL #4 DWL.'s SPA. ® 1'-0" O.C. T.O. EXIST. CONC. WALL - .. [REF. PLAN] 12 (TYP. EA. FACE)L 0'-0- (9.90')[*] GRATING MFG.'s STANDARD AL M * REF. PLAN FRAME ASSEMBLY REF. NOTE 2 r z . " v o [ ] GRATING MFG.'s STANDARD AL ( ) M J CAULK & SEAL JT. & INSTALL #4 HORZ. BARS SPA. CSD 1 -0 O.C. i [�'•] FRAME ASSEMBLY (REF. NOTE 2) " ° �. 2 3 - WATERPROOF SEALANT N (TYP. EA. FACE) ° . .*. ° [�•] N v (REF. DETAIL 4.S-4 (SIM.)) N CAULK & SEAL JT. w/' SONNEBORN #4 BARS w/ 90' HOOKS SPA. ® a . NP1 ELASTOMERIC POLYURETHANE 1'-0" O.C. (EA. FACE) ° .. °. N T.O. EXIST. CONC. SLAB SEALANT (TYP. EA. FACE) [CONT.] �a ANCHOR DWL.'s TO EXIST. WALL ; EL -7'-6" (2.40')[*] w/ HILTT-HIT HY200 ADHESIVE (EMBED 44" (MIN.)) #4 DWL.'s & HORZ. REINF. BARS ° ANCHOR DWL.'s TO EXIST. WALL a (REF. DETAIL 4.S-4) ° w/ HILTT-HIT HY200 ADHESIVE a (EMBED 4j" (MIN.)) (2) CONT. BEADS OF GREENSTREAK ANCHOR DWL.'s TO EXIST. SLAB (2) CONT. BEADS OF GREENSTREAK 2"(*) CLR. LEAKMASTER LV -1 (1 BEAD EA. FACE) LEAKMASTER LV -1 (1 BEAD EA. FACE) (TYP.) 2" CLR. EXIST. REINF. CTR'D IN WALL (*) m [O/F OF DWL. REINF.] w/ HILA -HIT HY200 ADHESIVE [O/F OF DWL. REINF.] " (TYP.) o (EMBED 6 (MIN.)) -0" 0 J T 3 - DETAIL - INTR. CHANNEL B.O. WALL MOD. 4 - DETAIL EXTR. CHANNEL WALL MOD. 5 - DETAIL INTR. CHANNEL T.O. WALL MOD. 3 SCALE: 1/2" = 1'-0" SCALE: 1/2" = 1'-0" SCALE: 1/2" = 1'-0" N O 0 M o I I v7 i 0 2 S NOTE ,>ruetr„ • REV: DESCRIPTION DATE: obi 1. INSTALL 1'-0" SQ. C.I.P. REINF. CONC. PEDESTAL COL. ANCHORED TO EXIST. WALL & SLAB. REFERENCE ° SECTIONS & DETAILS FOR ADD'L INFO & REQUIREMENTS. v & CREED co 2. COAT ALL ALUMINUM SURFACES IN CONTACT w/ CONCRETE w/ BITUMASTIC. _Cape Fear 3. INSTALL BAR & DWL. ASSEMBLIES w/ 2" EXTR. SIDE CLEAR DISTANCE, 1j" TOP CLEAR DISTANCE & 1" CLEAR DISTANCE FROM EMBEDDED E.O. GRATING ASSEMBLY FRAME. 243 NORTH FRONT STREET Public Utility Authority N 4. FOR ALL PRODUCTS NOTED, INSTALL IN ACCORDANCE w/ MFG.'S REQUIREMENTS & RECOMMENDATIONS. WILMINGTON, NORTH CAROLINA 28401 Stewardship. Sustainablifity. Service. 5. REFERENCE DWG. S-1 FOR ADDITIONAL GENERAL NOTES, MATERIAL SPECIFICATION INFORMATION & TELE: (910) 343-1048 REQUIREMENTS. FAX: (910) 251-8282 LICENSE: F-1222 TRUCTURAL OF FRAMING / UV MODS CAPE FEAR PUBLIC UTILITY AUTHORITY SOUTHSIDE WWTP UV DISINFECTION SYSTEM CAPE FEAR PUBLIC UTILITY AUTHORITY 235 GOVERNMENT CENTER DRIVE WILMINGTON, NC 28403 OFFICE: (910)332-6560 el DATE: JUNE 2018 SCALE: AS NOTED DRAWN BY: WFB CHECKED BY- AWB Y:AWB PROJECT N0. 7123-0002 SHEET NO: S-4 .x. v r .. o A o EXIST. C.I.P. REINF. CONC. EXIST. C.I.P. REINF. CONC. M STM. SLAB 1'-0"(*) 5'-5 1/2- '_0 4'-5 1/2- 8"(*) BTM. SLAB 1'-0"(*) 5'-5 1/2- '-0 4'-5 1/2- 8"(*) o [REF. PLAN] (REF. PLAN) [REF. PLAN] [REF. PLAN] (REF. PLAN) [REF. PLAN] N 1 - SECTION - THRU UV MOD & CANOPY FRAMING 2 - SECTION - THRU UV MOD & CANOPY FRAMING co m M SCALE: 3/8" = 1'-0" SCALE: 3/8" = 1'-0" x fi N 1'-0" (2) CONT. #4 HORZ. BARS N) (2) CONT. . #4 HORZBARS TYP#3 DWL.'s w/ 90' HOOKS (REF. NOTE 3) ( . (HOOKS SHOWN OFFSET FOR CLARITY) M 2" CLR. (REF. NOTE 3) #3 DWL.'s w/ 90' HOOKS " [REF. NOTE 31 N #4 BARS SPA. ®8 O.C. (TYP.) CONT." CHAMFER (HOOKS SHOWN OFFSET FOR 'CLARITY) EA. WAY (® MID -DEPTH) T.O. CONC. MOD/AL GRATING X T.O. CONC. MOD AL GRATING [REF. NOTE 3] EL 0'-6" (10.40') EL 0'-6" (10.40AL BAR GRATING [REF. PLAN] ') N [REF. PLAN] a AL BAR GRATING itCIOT.O. EXIST. CONC. WALL #4 DWL.'s SPA. ® 1'-0" O.C. T.O. EXIST. CONC. WALL - .. [REF. PLAN] 12 (TYP. EA. FACE)L 0'-0- (9.90')[*] GRATING MFG.'s STANDARD AL M * REF. PLAN FRAME ASSEMBLY REF. NOTE 2 r z . " v o [ ] GRATING MFG.'s STANDARD AL ( ) M J CAULK & SEAL JT. & INSTALL #4 HORZ. BARS SPA. CSD 1 -0 O.C. i [�'•] FRAME ASSEMBLY (REF. NOTE 2) " ° �. 2 3 - WATERPROOF SEALANT N (TYP. EA. FACE) ° . .*. ° [�•] N v (REF. DETAIL 4.S-4 (SIM.)) N CAULK & SEAL JT. w/' SONNEBORN #4 BARS w/ 90' HOOKS SPA. ® a . NP1 ELASTOMERIC POLYURETHANE 1'-0" O.C. (EA. FACE) ° .. °. N T.O. EXIST. CONC. SLAB SEALANT (TYP. EA. FACE) [CONT.] �a ANCHOR DWL.'s TO EXIST. WALL ; EL -7'-6" (2.40')[*] w/ HILTT-HIT HY200 ADHESIVE (EMBED 44" (MIN.)) #4 DWL.'s & HORZ. REINF. BARS ° ANCHOR DWL.'s TO EXIST. WALL a (REF. DETAIL 4.S-4) ° w/ HILTT-HIT HY200 ADHESIVE a (EMBED 4j" (MIN.)) (2) CONT. BEADS OF GREENSTREAK ANCHOR DWL.'s TO EXIST. SLAB (2) CONT. BEADS OF GREENSTREAK 2"(*) CLR. LEAKMASTER LV -1 (1 BEAD EA. FACE) LEAKMASTER LV -1 (1 BEAD EA. FACE) (TYP.) 2" CLR. EXIST. REINF. CTR'D IN WALL (*) m [O/F OF DWL. REINF.] w/ HILA -HIT HY200 ADHESIVE [O/F OF DWL. REINF.] " (TYP.) o (EMBED 6 (MIN.)) -0" 0 J T 3 - DETAIL - INTR. CHANNEL B.O. WALL MOD. 4 - DETAIL EXTR. CHANNEL WALL MOD. 5 - DETAIL INTR. CHANNEL T.O. WALL MOD. 3 SCALE: 1/2" = 1'-0" SCALE: 1/2" = 1'-0" SCALE: 1/2" = 1'-0" N O 0 M o I I v7 i 0 2 S NOTE ,>ruetr„ • REV: DESCRIPTION DATE: obi 1. INSTALL 1'-0" SQ. C.I.P. REINF. CONC. PEDESTAL COL. ANCHORED TO EXIST. WALL & SLAB. REFERENCE ° SECTIONS & DETAILS FOR ADD'L INFO & REQUIREMENTS. v & CREED co 2. COAT ALL ALUMINUM SURFACES IN CONTACT w/ CONCRETE w/ BITUMASTIC. _Cape Fear 3. INSTALL BAR & DWL. ASSEMBLIES w/ 2" EXTR. SIDE CLEAR DISTANCE, 1j" TOP CLEAR DISTANCE & 1" CLEAR DISTANCE FROM EMBEDDED E.O. GRATING ASSEMBLY FRAME. 243 NORTH FRONT STREET Public Utility Authority N 4. FOR ALL PRODUCTS NOTED, INSTALL IN ACCORDANCE w/ MFG.'S REQUIREMENTS & RECOMMENDATIONS. WILMINGTON, NORTH CAROLINA 28401 Stewardship. Sustainablifity. Service. 5. REFERENCE DWG. S-1 FOR ADDITIONAL GENERAL NOTES, MATERIAL SPECIFICATION INFORMATION & TELE: (910) 343-1048 REQUIREMENTS. FAX: (910) 251-8282 LICENSE: F-1222 TRUCTURAL OF FRAMING / UV MODS CAPE FEAR PUBLIC UTILITY AUTHORITY SOUTHSIDE WWTP UV DISINFECTION SYSTEM CAPE FEAR PUBLIC UTILITY AUTHORITY 235 GOVERNMENT CENTER DRIVE WILMINGTON, NC 28403 OFFICE: (910)332-6560 el DATE: JUNE 2018 SCALE: AS NOTED DRAWN BY: WFB CHECKED BY- AWB Y:AWB PROJECT N0. 7123-0002 SHEET NO: S-4