HomeMy WebLinkAboutWQCS00340_Application_20180920 IIGHTANGLE ENGINEERING, PC 212 Princess Street Wilmington,NC 28401 Tel.(910)251-8544 Fax(910)251-2208 September 20, 2018 Deborah Gore PERCS Unit, NCDEQ 512 North Salisbury Street, Suite 1304C Raleigh, NC 27604 Re: System Wide Wastewater Collection Permit, Town of Holden Beach WQCS00340 Attached is the Form CSA 04/2016 with supporting documentation for the Town of Holden Beach. Please let me know if you have further questions or comments. Thank you, Shane Lippard, P.E. Vice President RECEIVED/DENR/DWR Cc: David Hewett,Town Manager SEP 2 6 2018 Water Resources Permitting Section I. IAPPLICANT INFORMATION: 1. Applicant's name(Municipality,Public Utility,etc):Town of Holden Beach 2. Facility Information: Name: Town of Holden Beach Collection System Permit No.: WQCS00340 3. Applicant type: ® Municipal ❑ State ❑ Privately-Owned Public Utility ❑County ❑Other: 4. Signature authority's name:David Hewett per 15A NCAC 02T.0106(b) Title:Town Manager 5. Applicant's mailing address: 110 Rothschild Street City: Holden Beach State:NC Zip:28462- 6. Applicant's contact information: Phone number: (910)842-6488 Fax number:(910)842-9315 Email address:david.hewett@hbtownhall.com II. CONTACT/CONSULTANT INFORMATION: 1. Contact Name: Chris Clemmons 2. Title/Affiliation: Public Works Director 3. Contact's mailing address: 110 Rothschild Street 4. City: Holden Beach State:NC Zip:28462- 5. Contact's information: Phone number:(910)842-6488 Fax number: (910)842-9315 Email address:pworks@hbtownhall.com III. GENERAL REQUIREMENTS: 1. New Permit or Premit Renewal? ❑New ® Renewal 2. County System is located in: Brunswick County 3. Owner&Name of Wastewater Treatment Facility(ies)receiving wastewater from this collection system: Owner(s)&Name(s):Brunswick County 4. WWTF Permit Number(s): W00023693-West Brunswick Regional WWTP 5. What is the wastewater type? 100%Domestic Ior %Industrial(See 15A NCAC 02T.0103(20)) I, Is there a Pretreatment Program in effect?®Yes or❑No 6. Wastewater flow:0.198 MGD(Current average flow of wastewater generated by collection system) 7. Combined permitted flow of all treatment plants: MGD 8. Explain how the wastewater flow was determined: ❑ 15A NCAC 02T.0114 or®Representative Data 9. Population served by the collection system: 637,2559 Homes IV. COLLECTION SYSTEM INFORMATION: 1. Line Lengths for Collection System: Sewer Line Description Length Gravity Sewer (miles) Force Main 3.75(miles) Vacuum Sewer 12.2(miles) Pressure Sewer (miles) APPLICATION CSA 04-16 Page 3 of 5 r I 2. Pump Stations for Collection System: Pump Station Type Number Simplex Pump Stations(Serving Single Building) Simplex Pump Stations(Serving Multiple Buildings) Duplex Pump Stations 4 3. Submit a list of all major(i.e.not simplex pump station serving a single family home)pump stations. Include the following information: D Pump Station Name D Physical Location D Alarm Type(i.e.audible,visual,telemetry, SCADA) D Pump Reliability(Can convey peak hourly wastewater flow with largest single pump out of service) D Reliability Source(permanent/portable generator,portable pumps) D Capacity of Station(Pump Station Capacity in GPM) 4. Submit a list of all high priority lines according per 15A NCAC 02T.0402(2)known to exist in the collection system. Head the list with"Attachment A for Condition V(4)"and include the system name. D Use the same line identification regularly used by the applicant D Indicate type of high priority line(i.e.aerial),material and general location V. COLLECTION SYSTEM ADMINISTRATION: 1. Provide a brief description of the organizational structure that is responsible for management, operation and maintenance of the collection system. Town of Holden Beach,Public Works Section 2. Indicate the current designated collection system operators for the collection system per 15A NCAC 08G.0201 Main ORC Name: Eric Long Certification Number: 990984 Back-Up ORC Name: Chris Clemmons Certification Number: 989191 See the"WQCS Contacts and ORC Report"for a current listing of the ORC(s)the Division has on file for WQCS permit 3. Approximate annual budget for collection system only: $3.0M 4. Submit a copy of your current annual budget. 5. Approximate capital improvement budge for the collection system only: $ 1.5M 6. Submit a copy of your current capital improvement plan. 7. Is this collection system currently a satellite system Yes or®No 8. Do any satellite systems discharge to this collection system ❑Yes or®No(If yes complete table below) Satellite System Contact Information(Name,Address,Phone Number) Complete for Satellite Systems that have a flow or capacity greater than 200,000 GPD(Average daily flow) 9. List any agreements or ordinances currently in place to address flows from satellite systems: APPLICATION CSA 04-16 Page 4 of 5 4 VI. COLLECTION SYSTEM COMPLIANCE: 1. Is a Response Action Plan currently in place ®Yes or❑No 2. If Yes,submit a copy of the Response Action Plan or see table 6 below. 3. Is a pump station contingency plan currently in place? ®Yes or❑No 4. If Yes,submit a copy of the pump station contingency plan or see table 6 below. 5. Is a comprehensive collection system map currently in place? ®Yes or❑No 6. Submit a submit a copy of the collection system map(CD or hardcopy)or indicate a schedule for completion 7. Thoroughly read and review the System-Wide Collection System Permit Conditions. Typically compliance schedules are only offered to NEW permit applicants and NOT permit renewals. Any compliance dates must be included within the permit prior to issuance or the permit holder will be found in violation upon inspection. Current If no,Indicate a Typical Permit Condition Compliance Compliance Compliance? Date Schedule I(4)—Grease ordinance with legal authority to inspect/enforce ®Yes ❑No 12— 18 mo. I(5)— Grease inspection and enforcement program ®Yes El No 12—18 mo. I(6)—Three to five year current Capital Improvement Plan. ®Yes ❑No 12— 18 mo. I(8)—Pump station contingency plan ®Yes ❑No 3 mo. I(9)—Pump station identification signs. ®Yes ❑No 3 mo. I(11)—Functional and conspicuous audible and visual alarms. ®Yes ❑No 3—6 mo. II(5)—Spare pumps for any station where one pump cannot handle peak flows alone(in a duplex station,the 2"d pump is ®Yes ❑No 6—9 mo. the spare if pump reliability is met). II(7)—Accessible right-of-ways and easements. ®Yes El No 6— 12 mo. II(9)—Response action plan with Items 9(a—h). ®Yes ❑No 3 mo. III(3)—Comprehensive collection system map ®Yes ❑No 10%per year For conditions not listed,compliance dates are not typically offered. List any permit conditions that may be difficult for the applicant to meet(attach clarification if needed): VII. APPLICANT'S CERTIFICATION per 15A NCAC 02T.0106(b): I,David Hewett attest that this application for Town of Holden Beach (Signature Authority's Name&Title from Item I.4) (Facility name from Item I.1) has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting information and attachments are not included,this application package will be returned to me as incomplete. Note: In accord. e with NC General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, o rtification in any .pplic.tion shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10,000 as wel . ivi -nalties up to '•25,110 per violation.• ti d._19/6 / Signature: Date: APPLICATION CSA 04-16 Page 5 of 5 IIGHT ANGLE ENGINEERING,PC 212 Princess Street Wilmington,NC 28401 Tel.(910)251-8544 Fax(910)251-2208 September 5, 2018 Deborah Gore PERCS Unit, NCDEQ 512 North Salisbury Street, Suite 1304C Raleigh, NC 27604 Re: System Wide Wastewater Collection Permit, Town of Holden Beach WQCS00340 Attached is the Form CSA 04/2016 with supporting documentation for the Town of Holden Beach. PP 9 Please let me know if you have further questions or comments. Thank you, Shane Lippard, P.E. Vice President Cc: David Hewett,Town Manager t Town of Holden Beach SANITARY SEWER OVERFLOW COMMUNICATION, ASSESSMENT, and SPILL RESPONSE PROCEDURE AS ADOPTED BY: The Town of Holden Beach Public Utilities Department August 4, 2009 1 PURPOSE: This plan is to be implemented in the event of a Sanitary Sewer Overflow, (SSO) or spill within the Collection System. The plan was developed to insure the key personnel response to every spill event within sixty(60)minutes of a reported event. INITIAL RESPONSE: Spills reported to or detected by collection system personnel require immediate attention. The Collection System ORC or his appointed Back-up Operator will make the preliminary assessment of the spill within 15 minutes after receiving report. That assessment includes visiting the spill site. The ORC or Back-up will determine the appropriate response and request assistance from key personnel as necessary. The attached call back list will be maintained current and be ranked according to essential response including, i.e. equipment operators. Local contractors may be employed as deemed necessary. Key personnel will, upon assessing the site, continue to document the event and determine the severity, magnitude, and potential environmental impact. Every effort should be made to minimize the spill event consistent with the containment and source control section of this plan. The safety of the respondent should in no way be compromised. Key personnel should implement recovery actions to eliminate the cause of obstruction and/or system failure as outlined in this plan. POST SPILL RESPONSE, (REPORTING): After containment is achieved,the Division of Water Quality, (DWQ)must be contacted as soon as possible but, in no case later than 24 hours after initial detection if; 1) The spill has reached surface waters, "Waters of the State" or 2) The spill exceeds one thousand gallons, (1,000 gals.) Every small spill must be logged on site including time, date, approximate volume, name of respondent. Spills that are fully contained and removed quickly and are less than one thousand gallons are not required to be reported to DWQ. However, a full spill report form will be filled out and kept on file. , KEY PERSONNEL CONTACT NUMBERS UPDATED 9/5/18 BY: Eric Long Semi-annual Collection ORC CONTACT/TITLE TELEPHONE NUMBER MOST IMPORTANT—Eric Long WORK: 910-842-6488 COLLECTION ORC HOME: 910-209-2523 CELL/PAGER: 910-279-5882 NUMBER TWO — Chris Clemmons WORK: 910-842-4314 COLLECTION ORC HOME: 910-846-3383 CELL/PAGER: 910-443-6301 ETC: POLICE DEPARTMENT IF NEEDED FOR TRAFFIC CONTROL: 910-842-6707 TOWN OFFICE: 910-842-6488 MAYOR: Alan J. Holden MANAGER: David Hewitt CLERK: Heather Finnell � i SOURCE CONTROL AND CONTAINMENT PROCEDURE Depending on the nature of the spill or overflow,the initial assessment should indicate the priority of source control and/or containment. 1) When the source can be isolated through valves,plugs or other methods, the flow should be discontinued immediately or reduced to the least possible volume. 2) If the pumps on the location are not operating the control panel should be checked for; a. Power ON? b. Check breaker. c. Breaker closed, check thermal overloads. (External button). d. Overload good, Check fuses, if you are trained to do so. e. Is pump straining? (Clogged with debris?) f. Do you smell a burnt motor?(contact vendor from list) g. Call for Electrician. (From attached list.) 3) Containment methods will typically include; a. Sand or dirt dikes and dams. (Small streams, creeks.) b. Holes or pits. (To prevent run off to surface waters.) If the spill event resulted from an area wide power outage you should contact Power Company and identify your site as critical. You must have account number for location. If the problem is mechanical in nature,retrieve parts from inventory and make repairs. Re-order parts as they are used! If the problem results from sewer blockage call for jet rodding machine. (In house or contractor from list?) , KEY CONTRACTORS AND VENDORS WATER AND SEWER CONTRACTORS TELEPHONE NUMBER Plumbing, Trenching and Digging Mar-Tech 910-755-5523 Plumb-Rite 910-579-3757 Carmicheal Construction 910-520-8846 Sewer Pump Trucks, Septic Tank Hauler, ETC. S & B Sewer Maintenance 910-253-8332 American Pipe Cleaning 910-686-0099 Southeastern Response and Remediation 800-310-6757 Contract Jet Rodder Bernie Liberton 910-443-3590 Electrical Contractors Southport Electric Company 910-457-6193 Coastal Carolina Electric 910-575-9004 Power Company (plus account number for each lift station) Brunswick Electric 910-754-4391 Parts and Equipment Vendors Airvac 574-223-3980 Hughes Supply 800-554-0763 Pipeline Supply 800-344-0924 Prime Equipment 800-222-7777 Miller Supply 800-334-6954 RESPONSE EQUIPMENT EQUIPMENT OPERATOR, IN HOUSE PHONR# Back Hoe Chris Clemmons (910)443-6301 Jet Rodder Bernie Liberton (910) 443-3590 Safety Equipment Scott Cunningham (910) 279-1799 Personal Protective Equipment Adam Sellers (910) 269-7796 RESPONSE SUPPLIES SUPPLY LOCATION VENDOR PHONE# Lime Brunswick Farm Supply (910) 287-6343 Straw Brunswick Farm Supply (910) 287-6343 SPILL OCCURRING ON: MAJOR INTERCEPTOR RIGHT OF WAY 1. Put up warning tape "DO NOT ENTER"around SSO site to restrict access. 2. In open areas lime, remove debris and lime site rotor-till if needed. Re-seed and mulch with straw. 3. In areas were there is under growth and small trees,flush area with potable water until no waste remains. Wait twelve to twenty four hours then lime the area. Be certain that lime does not flush to receiving stream. NOTE: DO NOT LIME IF RAIN IS FORECASTED. IN CITIZEN'S YARD 1. Till entire area if possible. Apply lime and follow with seed and straw. 2. If waste/debris not visible apply lime and 2 inches of top soil and mix thoroughly. Apply lime lightly, seed and mulch. ON ASPHALT OR CONCRETE 1. Set up containment at or near the storm drainage system. Do not let the spill enter the storm drain system. 2. Put up Black or Red "DO NOT ENTER"tape around the SSO area. 3. Spread lime on spillage and sand or other material to a depth of one inch.Let this material absorb for one hour,then sweep up. Dispose of debris appropriately. If spill is still evident repeat application. 4. After removing the contaminated material,wash down area with high pressure water and bleach. 5. Pump clean up materials and wash water into sanitary sewer. IN A CREEK OR STREAM 1. Take conductivityreadingsupstream of the creek u stream and downstream to determine were temporary dam should be placed. 2. The dam should be constructed near a manhole which is accessible to the jet rodder and vacuum truck. 3. Dam should be placed below the spill as indicated by low conductivity reading. 4. Construct a dam sized to contain the flow of water plus any flush water added during clean up. 5. Station to pumps at clean up site, one to use one for back- up. 6. Have a back hoe at the site for dam repairs as needed. 7. Wash down all rip rap in stream bed until no residue is evident. 8. Put up warning tap "DANGER DO NOT ENTER". At spill site and 400 feet down stream. 9. Pull stream samples for fecal coliform. Upstream and Downstream. 10. Repeat sampling until normal,background counts 500 cts/100 ml. 11. If settled sludge evident sweep bottom until clean. 12. If creek or stream is recreational water notify the affected community and local officials as soon as the problem is discovered. r k. z `"' ,ac• .' ° ,01' sem_ ?- u ` Fat Free Sewers From the Holden Beach Public Works Department Grease blockage in sewer pipes is a serious maintenance problem for both the Town and private property owners. When grease washes down the sink, it sticks to the insides of sewer pipes. The build-up restricts flow and can block pipes completely, causing raw sewage to back up into your home or overflow into streets and streams. Home garbage disposals don't keep grease out of sewer pipes and products that claim to dissolve grease may dislodge a blockage, but will only cause problems further down the line. How You Can Help Here are some guidelines for keeping sewers fat free. In Your Home • Never our grease down sinks or toilets. P • Pour grease and oil into a can and put it in the trash. • Compost your organic waste. • Scrape other food scraps into a can or into the trash. • Catch food scraps with baskets or strainers in sink drains and throw scraps in the garbage. For Restaurant and Building Owners • Recycle grease and oil. • Don't pour grease or oil into sinks, floor drains or onto a parking lot or street. • Use a grease trap or interceptor that is designed, installed and maintained correctly. • Never put solids into grease traps or interceptors. • Check and maintain grease traps and interceptors regularly. Public Works Department Mailing Address: Town of Holden Beach Phone: 910-842-6488 P.O. Box 449 110 Rothschild Street Fax: 910-842-9315 Supply, NC 28462 Holden Beach,NC www.hbtownhall.com PUMP STATION (please complete one form for each pump station) Name of facility: Pump Station #1 Contact person: Eric Long Phone number: 910-279-5882 Location of the Pump Station: 112 Jordan Blvd. Holden Beach, NC 28462 1. How often is pump station inspected? X once per day twice per day (use all that apply) once per week days per week other (explain) 2. What is the pump station capacity? 744 GPM Does the pump station have a flow meter, pump counters or other means to measure flow? X Yes No 3. Does the pump station have a backup power source? X Yes No If Yes, what type? X Portable generator which can be moved to site Standby generator on site Alternate power feed If portable generator is used, how many other pump stations does the generator serve? 3 How often is the generator tested? twice per year (Mo./Yr.) When was the generator last load-tested? March, 2009 (Mo./Yr.) Was the test successful? X Yes No If No, what action was taken to address? If no backup power exists, please explain why: 4. Does the pump station have a working alarm system? X Yes No On site alarm system: X High water audio alarm X High water visual alarm X Other (describe) low vacuum Telemetry Monitoring System: X Wet well high level Wet well low level X Dry well high level High/low pH X High/low current X AC power status Please describe other alarm systems at the pump station. 5. Is there a spare pump available or an adequate spare parts inventory to replace or rebuild pump? X Yes No If No, what actions are being undertaken to address? PUMP STATION (please complete one form for each pump station) Name of facility: Pump Station #2 Contact person: Eric Long Phone number: 910-279-5882 Location of the Pump Station: 484 Ocean Blvd. West Holden Beach, NC 28462 1. How often is pump station inspected? X once per day twice per day (use all that apply) once per week days per week other (explain) 2. What is the pump station capacity? 451 GPM Does the pump station have a flow meter, pump counters or other means to measure flow? X Yes No 3. Does the pump station have a backup power source? X Yes No If Yes, what type? X Portable generator which can be moved to site Standby generator on site Alternate power feed If portable generator is used, how many other pump stations does the generator serve? 3 How often is the generator tested? twice per year (Mo./Yr.) When was the generator last load-tested? March, 2009 (Mo./Yr.) Was the test successful? X Yes No If No, what action was taken to address? If no backup power exists, please explain why: 4. Does the pump station have a working alarm system? X Yes No On site alarm system: X High water audio alarm X High water visual alarm X Other (describe) low vacuum Telemetry Monitoring System: X Wet well high level Wet well low level Dry well high level High/low pH X High/low current X AC power status Please describe other alarm systems at the pump station. 5. Is there a spare pump available or an adequate spare parts inventory to replace or rebuild pump? X Yes No If No, what actions are being undertaken to address? PUMP STATION (please complete one form for each pump station) Name of facility: Pump Station #3 Contact person: Eric Long Phone number: 910-279-5882 Location of the Pump Station: 799 Ocean Blvd. West Holden Beach, NC 28462 1. How often is pump station inspected? X once per day twice per day (use all that apply) once per week days per week other (explain) 2. What is the pump station capacity? 340 GPM Does the pump station have a flow meter, pump counters or other means to measure flow? X Yes No 3. Does the pump station have a backup power source? X Yes No If Yes, what type? X Portable generator which can be moved to site Standby generator on site Alternate power feed If portable generator is used, how many other pump stations does the generator serve? 3 How often is the generator tested? twice per year (Mo./Yr.) When was the generator last load-tested? March, 2009 (Mo./Yr.) Was the test successful? X Yes No If No, what action was taken to address? If no backup power exists, please explain why: 4. Does the pump station have a working alarm system? X Yes No On site alarm system: X High water audio alarm X High water visual alarm X Other(describe) low vacuum Telemetry Monitoring System: X Wet well high level Wet well low level Dry well high level High/low pH X High/low current X AC power status Please describe other alarm systems at the pump station. 5. Is there a spare pump available or an adequate spare parts inventory to replace or rebuild pump? X Yes No If No, what actions are being undertaken to address? • PUMP STATION (please complete one form for each pump station) Name of facility: Pump Station #4 Contact person: Eric Long Phone number: 910-279-5882 Location of the Pump Station: 1244 Ocean Blvd. West Holden Beach, NC 28462 1. How often is pump station inspected? X once per day twice per day (use all that apply) once per week days per week other (explain) 2. What is the pump station capacity? 347 GPM Does the pump station have a flow meter, pump counters or other means to measure flow? X Yes No 3. Does the pump station have a backup power source? X Yes No If Yes, what type? X Portable generator which can be moved to site Standby generator on site Alternate power feed If portable generator is used, how many other pump stations does the generator serve? 3 How often is the generator tested? twice per year (Mo./Yr.) When was the generator last load-tested? March, 2009 (Mo./Yr.) Was the test successful? X Yes No If No, what action was taken to address? If no backup power exists, please explain why: 4. Does the pump station have a working alarm system? X Yes No On site alarm system: X High water audio alarm X High water visual alarm X Other (describe) low vacuum Telemetry Monitoring System: X Wet well high level Wet well low level Dry well high level High/low pH X High/low current X AC power status Please describe other alarm systems at the pump station. 5. Is there a spare pump available or an adequate spare parts inventory to replace or rebuild pump? X Yes No If No, what actions are being undertaken to address? • OPERATION & MAINTENANCE EVALUATION 1. Is staff designated full-time for collection system operation and maintenance? X Yes No 2. Do you have a list of 24 hour contacts? X Yes No (If Yes, please attach) 3. Do you have an emergency equipment list? X Yes No (If Yes, please attach) 4. Staff distribution/time allocation: Number Total staff employed hours/week Collection System (incl. part-time) 7 24 Pump Stations 4 19 I/I Correction 4 12 5. Are map(s) of the collection system available? X Yes No 6. Total number of pump stations: 4 (Please complete a Pump Station form for each station.) 7. Is a preventative maintenance program in effect? X Yes No (If Yes, please attach) If yes, does it include: a. Maintaining logs/records X Yes No b. Determining equipment/system malfunction rates X Yes No c. Establishing schedules X Yes No d. I/I evaluation X Yes No e. Manhole inspection X Yes No f. Sewer cleaning program Yes No g. Hydrogen sulfide monitoring and control Yes No h. Lift station operation X Yes No i. Easement/right-of-way maintenance Yes No j. "Walking" or visual observation of lines Yes No k. Spare parts inventory X Yes No 8. Please describe what type of ongoing inspection program for the collection system exists: A daily inspection of all pumps, meters and how all valve pits are operating. 9. Please describe the schedule for line cleaning: Vaccuum systems are sealed. There is no access to clean. 10. Is there a sewer use ordinance? X Yes_No. Is there a grease ordinance? X Yes_No If yes, please identify the responsible party for ensuring the ordinance(s) is enforced. Eric Long / Town of Holden Beach (name of responsible person/agency). 11. Please describe any sewer use ordinance enforcement practices that exist: Inspection of every house before hook-up, then once a year on the entire system. COLLECTION SYSTEM EVALUATION 1. Please estimate how many miles of sewer line are in your collection system 17 < 100 mi. 100-500 mi. 501-1,000 mi. > 1,000 mi. 2. How many pump stations are in your collection system? 4 3. Please list any problem areas within your collection system. Include exact location of problems. (e.g. Chronically surcharging manholes, pump stations which frequently fail, lines with severe infiltration and inflow, etc.) None 4. Please rank the problems listed in No. 3 in order of importance. If possible, include an estimated date by which the problem will be appropriately addressed. 5. Please describe any ongoing efforts or plans to rehabilitate and/or renovate the collection system. Included exact location of ongoing or planned work. (e.g. Infiltration and inflow studies, pump station upgrades, pipe replacement, etc.) We plan to add flanges to all stations for faster hook up of diesel pumps in case of an emergency. Each year we buy two new pumps, that way when the life span of the pumps expire, we have new ones already. NOTE: Please attach any additional sheets and/or information if needed. SPILL RESPONSE PLAN EVALUATION 1. Do you have a current 24-hour contact list which includes phone numbers of key personnel and/or contractors? X Yes No (If yes, please attach.) 2. Do you have an equipment list which includes what functional equipment is available and where it is located? X Yes No (If yes, please attach.) 3. Do you have the staff resources to make an on-site assessment of a spill within two hours or notification of the spill? X Yes No (If No, please explain below.) 4. Please list your standard spill response procedures: attached 5. Is your spill response plan readily available to all essential personnel? X Yes No If No, please explain why: 6. Are all essential personnel familiar with the spill response plan and clearly understand its contents? X Yes No If No, please explain why: Ordinance 18-10 Town of Holden Beach Fiscal Year 2018/2019 Budget Ordinance An Ordinance to appropriate revenues and authorize expenses for the Fiscal Year beginning 1 July 2018 and ending 30 June 2019. BE IT ORDAINED by the Board of Commissioners of the Town of Holden Beach North Carolina that revenues and expenses for the Fiscal Year 2018/2019 are authorized as set out below: Part I:General Fund GENERAL FUND REVENUES CREDIT CARD SITE FEE GENERAL 1,000 AD VAL TAXES-CURRENT 2,660,648 AD VAL TAXES-PRIOR 19,000 VEHICLE TAXES 16,500 PNLTY& INT-AD VAL TAX 6,000 VEHICLE STICKERS 500 TAX PMTS TO BE REFUNDED 100 MISCELLANEOUS 7,000 SIDEWALK DEPOSIT 500 PLUMBING SCREEN SALES 150 BLUE CAN HOME RECYCLING 21,060 CHRISTMAS DECORATIONS 500 UTILITIES FRANCHISE TAX 155,060 SALES ON TELECOMM-UTIL FR 8,337 SALES TAX ON VIDEO PROGRM 37,520 BEER&/OR WINE TAX 2,600 POWELL BILL 34,512 LOCAL SALES& USE TAX 139,511 CAMA CONTRACT 3,000 COURT COSTS 200 PARKING VIOLATIONS 100 ORDINANCE VIOLATIONS 1,200 Mosquito Contract 1,250 BUILDING PERMITS 149,469 CAMA PERMITS 3,000 ZONING FEES 9,699 ELECTRICAL INSPECTION 22,106 MECHANICAL INSPECTION 28,106 PLUMBING INSPECTIONS 12,699 ADMINISTRATIVE FEE-INSP 600 HOMEOWNERS RECOVERY FUND 350 REINSPECTION FEE 200 SALES TAX REFUND 7,500 DEMOLISH PERMIT 450 SALE OF MATERIALS 500 SALE OF TOWN FLAGS 100 SALE OF FIXED ASSETS 5,000 Transfers from SRF Canal Dredging 61,000 FUND BALANCE APPROPRIATED 30,273 Total for Revenue 3,447,300 1 Expenses: GOVERNING BODY EXPENSES SALARIES-MAYOR AND COMMISSIONERS 7,800 PROFESSIONAL SERVICES 48,000 GOVERNING BODY-FICA 600 COMMUNICATIONS 6,600 PUBLIC RELATIONS 1,500 COMMUNITY EVENTS 1,500 TRAVEL 2,000 AB-TRAVEL&TRAINING 2,000 HURRICANE PREPARATION 2,100 DECORATIONS 500 ADVERTISING 750 AB-ADVERTISING MEETINGS 500 HOLDEN BEACH FLAG 500 AB-SUPPLIES& MATERIALS 3,000 OPERATIONAL CONTINGENCIES 5,000 NEW TOWN HALL DEBT SERVICE 268,274 New Town Hall Ops, Maint and Repair 73,700 CONTRIBUTIONS 15,750 TRANSFER TO BPART FUND 564,866 TRANSFER TO BEACH RE-NOURISHMENT FUND 241,877 Tata! 1,246,817 2 • ADMINISTRATION EXPENSES SALARIES 339,095 SALARIES-OVERTIME 3,675 FICA 24,337 GROUP INSURANCE 70,420 RETIREMENT 26,565 401K EMPLOYERS MATCH 13,670 COMMUNICATIONS 50,000 PRINTING 6,000 TRAVEL&TRAINING 8,000 M & R-EQUIPMENT 3,500 ADVERTISING 1,000 DEPT SUPPLIES& MATERIALS 5,500 UNIFORMS 1,000 REWARDS AND WELLNESS PRGR 2,000 SAFETY PROGRAMS ALL DEPTS 1,500 CONTRACTED SERVICES 18,000 DUES&SUBSCRIPTIONS 4,000 INSURANCE & BONDS 40,000 EQUIPMENT 29,000 Total 647,261 3 POLICE EXPENSES SALARIES 394,792 SALARIES-OVERTIME 48,500 FICA 31,474 GROUP INSURANCE 98,588 RETIREMENT 37,680 PD EMPLOYER'S 401K CONTRIBUTION 19,877 COMMUNICATIONS 27,500 TRAVEL&TRAINING 5,500 COMMUNITY WATCH 500 M&R-EQUIPMENT 2,500 M & R-VEHICLES 5,000 GAS,OIL&TIRES 22,000 DEPT SUPPLIES&MATERIALS 4,000 UNIFORMS 2,000 POLICE INOCULATIONS 500 EQUIPMENT 5,000 CAP OUTLAY-VEHICLES&EQUIP 64,921 PD CARS-ACCIDENT REPAIRS 2,000 Total 772,332 4 INSPECTIONS EXPENSES SALARIES 153,142 SALARIES OVERTIME 1,500 FICA 10,980 GROUP INSURANCE 42,252 RETIREMENT 11,985 401K EMPLOYERS MATCH 6,250 COMMUNICATIONS 6,000 PRINTING 1,500 TRAVEL&TRAINING 7,000 M &R-VEHICLES 7,500 ADVERTISING 2,000 GAS, OIL&TIRES 3,500 DEPT SUPPLIES& MATERIALS 4,500 BUILDING INSP- UNIFORMS 1,000 CONTRACTED SERVICES 20,000 DUES&SUBSCRIPTIONS 1,000 HOMEOWNERS' RECOVERY FUND 600 EQUIPMENT PURCHASE 7,500 Total 288,208 5 PUBLIC WORKS,STREETS, BUILDINGS AND GROUNDS EXPENSES SALARIES 58,134 SALARIES OVERTIME 3,000 PROFESSIONAL SERVICES 4,000 FICA 4,341 GROUP INSURANCE 14,084 RETIREMENT 4,738 401K EMPLOYERS MATCH 2,000 UTILITY-STREET LIGHTS 52,954 BUILDINGS UTILITY PAYMENT 1,250 TRAVEL 1,000 BLDINGS&GROUNDS MAINT/SUP 25,000 M & R EQUIPMENT 17,500 M &R VEHICLES 6,000 MAINT&REP STREETS 9,500 MAINT& REPAIR BULKHEADS 22,000 STREET DRAINAGE PROJECTS 5,000 STREET SIGN REPLACEMENT 3,500 ADVERTISING 150 GAS,OIL&TIRES 15,500 DEPT SUPPLIES& MATERIALS 5,000 UNIFORMS 925 STREET PAVING PROJECTS 112,500 SIDEWALK MAINTENANCE 2,000 Total 370,075 6 SANITATION EXPENSES SALARIES FULL TIME 34,182 SALARIES OVERTIME 4,500 FICA 2,746 GROUP INSURANCE 14,084 RETIREMENT 2,998 401K EMPLOYERS MATCH 1,750 TRAVEL&TRAINING 500 MAINT&REPAIRS EQUIPMENT 300 DEPT SUPPLIES&MATERIALS 12,500 SANITATION UNIFORMS 925 CONTRACTED SERVICES 28,402 BLUE CAN HOME RECYCLING 18,720 SOLID WASTE TIPPING FEES 1,000 Total 122,607 Total General Fund Expenditures: FY18-19 GOVERNING BODY 1,246,817 ADMIN 647,261 POLICE 772,332 INSPECTION 288,208 PUBLIC WORKS 370,075 SAN ITATION 122,607 TOTAL 3,447,300 7 PART II. Water and Sewer Fund WATER AND SEWER FUND REVENUES CREDIT CARD SITE FEE WATER 900 INTEREST ON INVESTMENTS 500 RENTS&CONCESSIONS 105,044 ADMINISTRATIVE FEES WATER 750 CAPITAL CHARGES CTY-SEWER 950,000 INTEREST ON CAPITAL CHRGS 15,000 CAPITAL CHARGES TOWN-SEWR 617,616 SEWER CAPACITY CHARGE 14,785 WATER USE CHARGES 897,727 WATER CAPACITY CHARGE 173,760 SPECIAL CHARGES FOR UTIL 2,750 Irrigation Meter Inspection Fees 14,760 SEWER USE CHARGES 807,315 AVAILABILITY FEE SEWER 1,750 TAP & CONNECTION FEES 75,000 TAP& CONNECT FEES-SEWER 23,500 RECONNECTION FEES 750 PNLTY & INTRST-BILLINGS 12,500 Fund Balance Appropriated 1,846,853 Total for Revenue 5,561,260 A sewer capital fee of$497.30 per developable property within the corporate limits of the Town of Holden Beach is authorized for the payment of debt service to fulfill the Town's sewer capital obligation. Said fee is to be billed concurrently with ad valorem property taxes and collected in accordance with applicable North Carolina General Statues. WATER AND SEWER FUND EXPENSES ADMIN EXPENSES SALARIES 38,044 SALARIES-OVERTIME 600 FICA 2,744 GROUP INSURANCE 14,084 RETIREMENT 2,995 401K EMPLOYERS MATCH 500 COMMUNICATIONS 42,500 PRINTING 1,500 EPA CC REPORT-ADMIN PREP 750 TRAVEL&TRAINING 5,000 M & R-EQUIPMENT 5,000 DEPT SUPPLIES&MATERIALS 2,000 CONTRACTED SERVICES 10,000 DUES&SUBSCRIPTIONS 5,500 TOTAL 131,217 8 OPERATIONS EXPENSES SALARIES 142,148 SALARIES-OVERTIME 7,000 PROFESSIONAL SERVICES 23,000 Profession&Services Irrigation Inspect 14,551 FICA 10,590 GROUP INSURANCE 45,773 RETIREMENT 11,559 401K EMPLOYERS MATCH 5,000 COMMUNICATIONS 2,000 UTILITIES 2,500 UTILITIES-PUMPING STATION 60,000 TRAVEL 2,000 M & R WATER TANK 64,308 M & R EQUIPMENT 6,450 OPERATION &MAINT VAC SYS 26,859 M& R VEHICLES 7,100 M & R WATER SYSTEM 39,874 CTY CAPITAL COSTS SEWER 1,151,941 GAS,OIL&TIRES 12,500 DEPT SUPPLIES&MATERIALS 3,500 O&M VACUUM STATIONS 135,000 METERS (NEW CONSTRUCTION) 40,000 UNIFORMS 3,000 CONTRACTED SERVICES 21,500 PURCHASES FOR RESALE 446,880 COUNTY O&M CHARGE SEWER 217,564 EQUIPMENT PURCHASE-WATER 138,600 PS II-IV VINYL FENCE 15,000 CAPITAL OUTLAY-VALVE PITS 40,000 CAP OUTLAY MAJ EQUIP SEWR 1,736,345 DEBT SERVICE SEWER 660,592 NEW EOC OPS, MAIN AND REPAIR 55,000 NEW EOC DEBT SERVICE 93,335 CONTRIBUTION TO CRF SEWER 14,785 CONTRIBUTION TO CRF WATER 173,790 Ops TOTAL 5,430,044 Total 5,561,260 9 PART III. Beach Preservation/Access&Recreation/Tourism(BPART) Fund BPART REVENUES ACCOM TAX 1,919,399 BRUNSWICK COUNTY CRP REFUND 26,160 ACCOMMODATION TAX PENALTY 200 INTEREST ON INVESTMENTS 6,500 MISCELLANEOUS BPART 8,000 RECREATION PROGRAMS 13,000 SALES TAX REFUND 1,500 TRANSFER FROM GENERAL FUND 564,866 FUND BALANCE APPROPRIATED 3,347,710 Total for Revenue 5,887,335 BPART EXPENSES DEBT SERVICE CENTRAL REACH 1,422,360 TRANSFER COUNTY ACCOM TAX 315,000 SALARIES-RECREATION 50,844 FICA- RECREATION 3,610 Group Insurance 14,084 RETIREMENT REC 3,940 401K EMPLOYERS CONTRIBUTION 1,000 INTERNSHIP 4,060 PROFESSIONAL SERVICES 50,000 ATM -CONTRACT FEES 50,000 PROFESSIONAL SRV-MAINLAND 3,500 PROFESSIONAL SERVICES-BEACH 15,000 Recreation Programs 12,500 Beautification Club 11,500 Jordan Blvd Ops, Mx and Repair 40,000 Starfish Fire Substation Upgrade 500 Starfish Fire Substation Ops, Mx, Rpr 6,000 Park and Rec Utilities 5,500 Dog Park 500 COMMUNICATIONS 8,000 Gas Oil and Tires 5,000 TRAVEL&TRAINING 12,000 PUBLIC REST ROOMS 20,000 10 • BEACH EQUIPMENT MAINTENAN 4,000 BEACH VEGETATION 70,000 SHORELINE MONITORING 25,000 DEBRIS REMOVAL 3,000 FESTIVAL&SECURITY 7,000 CONCERTS 31,000 HOLDEN BEACH PROMOTION 40,000 CHAMBER OF COMMERCE 3,000 Contributions BPART(Donations) 4,500 ACCESS& RECREATION 80,000 WASTE IND 2ND PICK-UP 85,000 SAND FENCE PROJECT 15,000 POCKET PARK 6280BW 1,500 HALSTEAD PARK 1,500 Rothschild Davis Park 30,000 LOCKWOOD FOLLY DREDGING 168,000 CONRIBUTION TO CAPITAL RESERVE 3,000,000 SALARIES BEACH PROJECT 27,528 OVERTIME- BEACH PROJECT 3,500 FICA BEACH PROJECT 2,203 RETIREMENT BEACH PROJECT 2,405 401K EMPLOYERS BEACH PRJT 2,300 Group Insurance Beach Project 10,563 CONRACT SERVICES SANITATION 85,000 BEACH RANGER SALARIES 32,000 BEACH RANGER SUPPLIES, EQUIPMENT,AND MAINT 14,500 BEACH RANGER GAS OIL AND TIRES 1,600 Salaries Police 48,794 Overtime Police 8,000 FICA Police 4,032 Insurance Police 14,084 Retirement Police 4,828 POLICE 401K EMPLOYERS CONTRIBUTION 2,600 Tota I 5,887,335 11 PART IV. Other Special Revenue Funds Harbor Acres Special Revenue Fund REVENUE BALANCE FORWARD 953,814 SRF HA INTEREST 300 SRF HA ASSESSMENTS 92,706 SRF HA PRIOR ASSESSMENTS 0 HA MISC REVENUE 62,944 Total 1,109,764 EXPENSE SRF Administration- HA 11,098 SRF Legal Fees- HA 11,098 SRF Construction-HA 832,323 SRF Surveying-HA 55,488 SRF Permitting CAMA-HA 27,744 SRF Permitting ACE& Other Agencies-HA 27,744 SRF Designs- HA 33,293 SRF Contract Docs, Plans, Specs-HA 55,488 SRF Construction Management, lnsp, Closeout-HA 27,744 SRF Transfer to General Fund- HA 27,744 Total 1,109,764 In accordance with North Carolina General Assembly Session Laws 2004-104 as amended and 2005-90; as such,a canal dredging fee of$320 per lot (per the Fiscal Year 2008/2009 assessment district resolution) for Holden Acres is hereby established for the Fiscal Year beginning 1 July 2018 and ending 30 June 2019. 12 Holden Beach Harbor Special Revenue Fund REVENUE BALANCE FORWARD 716,334 SRF HBH INTEREST 250 SRF HBH ASSESSMENTS 139,138 SRF HBH PRIOR ASSESSMENTS 900 HBH MISC REVENUE 47,264 Total 903,886 EXPENSE SRF Administration- HBH 9,039 SRF Legal Fees-HBH 9,039 SRF Construction-HBH 677,915 SRF Surveying- HBH 45,194 SRF Permitting CAMA- HBH 22,597 SRF Permitting ACE &Other Agencies 22,597 SRF Designs- HBH 27,117 SRF Contract Docs, Plans,Specs-HBH 45,194 SRF Construction Management, lnsp, Closeout-HBH 22,597 SRF Transfer to General Fund- HBH 22,597 Total 903,886 In accordance with North Carolina General Assembly Session Laws 2004-104 as amended and 2005-90; as such,a canal dredging fee of$400 per lot(per the Fiscal Year 2008/2009 assessment district resolution)for Holden Beach Harbor is hereby established for the Fiscal Year beginning 1 July 2018 and ending 30 June 2019. 13 Heritage Harbor Special Revenue Fund REVENUE BALANCE FORWARD 375,421 SRF HH INTEREST 250 SRF HH ASSESSMENTS 136,379 SRFHH PRIOR YEAR ASSESSMENTS 1,000 HH MISC REVENUE 24,779 Total 537,829 EXPENSE SRF Administration-HH 5,378 SRF Legal Fees- HH 5,378 SRF Construction- HH 403,372 SRF Surveying- HH 26,891 SRF Permitting ACE&Other Agencies HH 13,446 SRF Permitting CAMA-HH 13,446 SRF Designs-NH 16,135 SRF Contract Docs, Plans, Specs- HH 26,891 SRF Construction Management, Insp, Closeout- HH 13,446 SRF Transfer to General Fund-HH 13,446 Total 537,829 In accordance with North Carolina General Assembly Session Laws 2004-104 as amended and 2005-90; as such, a canal dredging fee of$400 per lot(per the Fiscal Year 2008/2009 assessment district resolution)for Heritage Harbor is hereby established for the Fiscal Year beginning 1 July 2018 and ending 30 June 2019. 14 , / t Part V: Capital Reserve Fund: The following Capital Reserve Funds are hereby established as separate funds in accordance with NCGS 159-18. Capital Reserve Fund Water 173,790 Capital Reserve Fund Sewer 14,785 Beach Re-nourishment& Inlet Management Fund 3,241,877 Capital Reserve Fund Water: 1. The purpose for the water capital reserve fund is to provide funding for expansion of the water system, not limited to,the research and funding of a second water tower. 2. The approximate period of time during which the monies will be accumulated will be five years. 3. The approximate amounts to be accumulated will be four hundred thousand dollars. 4. The monies will be derived from water capacity fees collected and transferred from the water/sewer fund under authority of HB436. Capital Reserve Fund Sewer: 1. The purpose for the sewer capital reserve fund is to increase sewer system capacities. 2. The approximate period of time during which the monies will be accumulated will be five years. 3. The approximate amount to be collected is seventy thousand dollars. 4. The monies will be derived from sewer capacity fees collected and transferred from the water/sewer fund under authority of HB 435. Beach Re-nourishment and Inlet Management Fund Based on the guidance and established goals for the FY18-19 budget year,the Board of Commissioners wish to create a Capital Reserve Fund in order to alleviate financial burden in future years for sand projects.According to the local Government Budget and Fiscal Control Act section 159-18: 1. The purpose/goal is to create a capital reserve fund for beach re-nourishment and inlet management projects. The intent is to escrow the funds until the Town's Special Obligation Bond is retired in Fiscal Year 2026/2027. 2. The monies will be accumulated for 9 years. 3. The maximum amount to be accumulated will be 10 million dollars. 4. The sources include an initial 3 million dollar transfer from the BPART fund. Subsequent amounts may be sourced from the General Fund as well as the BPART Special Revenue Fund. 15 • Part VI:Capital Improvement Plan The Capital Improvement Plan is hereby amended and established for Fiscal Year 18/19 through 25/26 is as shown in Appendix A. Part VII: Budget Summary and Administration General 3,447,300 Water&Sewer 5,561,260 BPART 5,887,335 Holden Beach Harbor Canal Dredging Special Revenue Fund 903,886 Heritage Harbor Canal Dredging Special Revenue Fund 537,829 Harbor Acres Canal Dredging Special Revenue Fund 1,109,764 Capital Reserve Fund Water 173,790 Capital Reserve Fund Sewer 14,785 Beach Re-nourishment& Inlet Management Fund 3,241,877 Total 20,877,827 16 Tax Rate,Valuation,Collection Rate and Tax Base An Ad Valorem Tax Rate of twenty two cents($.22) per one hundred dollars($100) at full valuation is levied for Fiscal Year 2018/2019. The Ad Valorem Tax Collection rate used to calculate the estimated ad valorem tax revenue is ninety eight point fifty four percent based on collection rate results from the fiscal year ended 30 June 2017.The total valuation for the new fiscal year is estimated to be one billion two hundred twenty six million three hundred thirty six thousand six hundred and eighty five dollars. Budget Administration This Budget Ordinance shall be the financial plan for the Holden Beach Municipal Government during the fiscal year beginning 1 July 2018 and ending 30 June 2019. The Board of Commissioners shall approve all reallocations of budgeted funds between Funds and may amend the Budget Ordinance at any time so long as the Budget Ordinance,as amended, satisfies the requirements of North Carolina General Statutes 159-8 and 159-13.The Budget Officer shall administer and shall insure that operating officials are provided guidance and sufficient details to implement their appropriate portion of the budget. In accordance with North Carolina General Statute 159-15 and 26, the Budget Officer may reallocate budgeted funds within a Fund without limitation and shall establish/maintain an accounting system designed to show in detail the Town's assets, liabilities, equities, revenues and expenditures. Effective Date and Approval. This Ordinance is effective 1 July 2018 as adopted this day of June, 2018. Atch: Appendix A- Capital Improvement Plan J.Alan Holden, Mayor ATTEST: Heather Finnell,Town Clerk 17 Capital Improvement Plan • • FY FY FY FY FY FY FY FY Total %of CtP 18/19 19/20 20/21 21/22 22/23 23/24 24/25 25/26 Revenues Revenues CIP REVENUES BY SOURCE General Fund-Operating Revenues 161,500 296,288 119,041 125,078 137,178 66,995 90,046 80,227 1,076,353 9.1% Water Sewer Fund-Operating Revenues 102,148 46,148 154,148 60,000 60,000 60,000 60,000 60,000 602,444 5.1% Water Sewer Fund Reserves 1,736,345 1,499,050 1,378,900 0 0 0 0 4,614,295 38.9% USDA Grant/Loan Proceeds 0 0 0 1,350,000 0 0 0 0 1,350,000 11.4% Water Capital Reserve Funds 0 0 0 400,000 0 0 0 0 400,000 3.4% Canal Dredging Special Revenue Fund 2,551,479 0 0 0 0 1,173,520 0 0 3,724,999 31.4% BPART 31,000 58,000 0 0 0 0 0 0 89,000 0.8% TOTAL 4,582,472 1,899,486 1,652,089 1,935,078 197,178 1,300,515 150,046 110,227 11,857,091 100.0% OP EXPENSES FY FY FY FY FY FY FY FY Total %of CIP BY FUND 18/19 19/20 20/21 21/22 22/23 23/24 24/25 25/26 Expenses Expenses General Fund Streets Resurfacing Sand Dune,Sand Piper,Sand Spur 112,500 0 0 0 0 0 0 0 112,500 0 9% Heron,High Point 0 121,288 0 0 0 0 0 0 121,288 10% Hight Point,Lois,Lumberton.Swordfish 0 0 119,041 0 0 0 0 0 119,041 1 0% Charlotte,Boyd,Gerda 0 0 0 125,078 0 0 0 0 125,078 1.1% Burlington,Bruns Av W(Boyd to Marker SS) 0 0 0 0 137,178 0 0 0 137,178 1.2% Brun Av W(Mark SS-High Pnt),Hrn Land Wynd 0 0 0 0 0 66,995 0 0 66,995 0.6% ;and Dollar 0 0 0 0 0 0 90,046 0 90,046 0.8% tuna 0 0 0 0 0 0 0 80,227 80,227 0.7% inspection Vehicle SUV 0 40,000 0 0 0 0 0 0 40,000 0.3% ?olice Vehicle SUV 49,000 0 0 0 0 0 0 0 49,000 0.4% 3eneratnrre-location 0 135,000 0 0 0 0 0 0 135,000 1.1% .icneral Fund Total 161,500 296,288 119,041 125,078 137,178 66,995 90,046 80,227 1,076,353 9 1% FY FY FY FY FY FY FY FY Total %of OP Water and Sewer 18/19 19/20 20/21 21/22 22/23 23/24 24/25 25/26 Expenses Expenses ` r At Station 1 120,150 1,378,900 0 0 0 0 0 0 1,499,050 12.6% .ilt Station 4(West)Hazard Mitigation 1,616,195 0 0 0 0 0 0 0 1,616,195 13.6% aft Station 2(Greensboro)Hazard Mitigation 0 120,150 1,378,900 0 0 0 0 0 1,499,050 12.6% WaterTowerRehab 46,148 46,148 46,148 0 0 0 0 0 138,444 1.2% %Vater Tower Two 0 0 0 1,750,000 0 0 0 0 1,750,000 14.8% Dodge Truck(21@ 28,000 56,000 0 28,000 0 0 0 0 0 84,000 0.7% lump Truck 0 0 80,000 0 0 0 0 0 80,000 0,7% Jac Truck 0 0 0 60,000 60,000 60,000 60,000 60,000 300,000 2.5% Water and Sewer Fund Total 1,838,493 1,545,198 1,533,048 1,810,000 60,000 60,000 60,000 60,000 6,966,739 58.8% Beach Parks Access Rec Tourism Walkways 31,000 28,000 0 0 0 0 0 0 59,000 0 5% 9ecreational Vehicle 30,000 0 0 0 0 0 0 30,000 0 3% 0 0 0 0 0 0 0 0 0 00% 3PART Total 31,000 58,000 0 0 0 0 0 0 89,000 0.8% :anal Dredging Special Revenue Widen Beach Harbor 903,886 0 0 0 0 102,535 0 0 1,006,421 17.8% -i arbor Acres 1,109,764 0 0 0 0 1,000,000 0 0 2,109,764 17.8% -leritage Harbor 537,829 A 0 0 0 70,985 0 0 608,814 5.1% 0.0% :anal Dredging Special Revenue Total 2,551,479 0 0 0 0 1,173,520 0 0 3,724,999 31 4% TOTAL ALL FUNDS 4,582,472 1,899,486 1,652,089 1,935,078 197,178 1,300,515 150,046 140,227 11,857,091 1000%