HomeMy WebLinkAboutNCG510550_Application_20180918September 18, 2018
Mr. Derek C. Denard
N. C. Division of Water Resources
Water Quality Permitting Section - NPDES
1617 Mail Service Center
Raleigh, NC 27699-1617
LLC
Speedway Office
P.O. Box 1500
Springfield, OH 45501
Telephone 937-864-3000
RECEIVED/DENR/DWR
SEP 25 2018
Water Resources
Permitting Section
Subject: RESUBMITTAL APPLICATION FOR GENERAL PERMIT NCG510000
GROUNDWATER REMEDIATION SYSTEM DISCHARGE
SPEEDWAY 7976 (FORMER WILCOHESS 357)
1005 CHARLOTTE HIGHWAY
TROUTMAN, IREDELL COUNTY, NORTH CAROLINA
MID -ATLANTIC JOB NO. OOOR1167.35
Dear Mr. Denard:
Speedway LLC is pleased to submit the enclosed Resubmittal Application for Coverage under
General Permit NCG510000 for the proposed discharge of treated groundwater from a mobile
Dual -Phase Extraction (DPE) system at the Speedway 7976 located at 1005 Charlotte Highway in
Troutman, North Carolina. As requested in the Division's correspondence dated July 6, 2018, the
enclosed application includes approval from the North Carolina Department of Transportation
(NCDOT) to discharge to the receiving stormwater system. Documentation acknowledging this
approval is provided in Attachment E. If you have any questions, please feel free to contact me at
(937) 863-6507 or Chuck Hoffman with Mid -Atlantic at (919) 250-9918.
Sincerely,
SPEEDWAY LLC
Z, �WC*4k
Bryan M. Witt
Environmental Representative
Enclosure: Application for Coverage under General Permit NCG510000
Attachment A — Site Maps
Attachment B — Narrative Description and Final Plans/Specifications
Attachment C — Analytical Monitoring Data
Attachment D — Alternatives to Direct Discharge Analysis
Attachment E — NCDOT Approval to Discharge to Stormwater System
Attachment F — Receiving Stream Flow Data
An Equal Opportunity Employer
Division of Water Resources
ffaNational Pollutant Discharge Elimination System (NPDES)
NCDENR Application for Coverage Under General Permit
NCG510000
Authorization to Construct groundwater remediation projects designed
to treat petroleum -contaminated groundwater.
NOTICE OF INTENT
[Required by 15A NCAC 02H .0127(d)l; [term definition see 15A NCAC 02H .0103(19 1
FOR AGENCY USE ONLY
Date Received
Month
Day
✓� ,,.Year
n
�;k E,
Certificate of Coverage
N
C
I G
5
1 1
1 n
b
o
Check #
Amount
Assigned To
(Please print or type)
1) Mailing address of owner/operator (address to which all permit correspondence will be mailed):
Company Name Speedway LLC
Company Contact Mr. Bryan M Witt
Street Address 500 Speedway Drive
City Enon State OH ZIP 45323 -1056
Telephone # 937-863-6507 Fax
Cell/Mobile # 937-605-8218 Email bmwitt@speedway.com
2) Location of facility producing discharge:
Facility Name
Speedway 7976 (former WilcoHess 357)
Facility Contact
Ms. Kat Jacobsen
Street Address
1006 Charlotte Highway
City
Troutman State NC ZIP 28166 -
County
Iredell
Telephone
704-528-4104 Fax
3) Physical location information:
Please provide a narrative description of how to get to the facility (use street names, state road numbers, and distance and
direction from a roadway intersection).
Heading north on I-77. take exit 42 for NC-115 S/US-21 S and take a right off the ramp onto US-21.
Facility will be immediately on the right (SE intersection of I-77 and US-21)
(A copy of a county map or USGS quad sheet with facility clearly located on the map is required to be submitted with
this application.) 1 Attachment A
Page 1 of 5 Revised 911113
NCG510000 New Application
4) This NPDES permit application applies to which of the following:
® New [term definition see 15A NCAC 02H .0103(16)1 or Proposed
Does the facility have an approved CAP?
® Yes —Date approved: 8/2/2016
❑ No —Please contact the Regional Office Groundwater Section to determine the status of CAP approval
and/or authorization to proceed if immediate remediation is recommended.
Regional Office contact person: Dan Graham, Mooresville Regional Office (704-663-1699)
Site Ranking (A - E): I-170-D GW incident #: 24101
❑ Modification
Please describe the modification:
❑ Renewal
Please specify existing permit number and original issue date: Click here to enter a date.
5) Does this facility have any other NPDES permits [term definition see 15A NCAC 02H .0103(15)]?
® Yes - List the permit numbers for all current NPDES permits for this facility: NCG080170
❑ No
6) Description of discharge: [Required by 15A NCAC 02H .0105(c)(1)]
a) Is the discharge directly to the receiving water? ® Yes ❑ No - If no, submit a site map with the pathway to t
potential receiving waters clearly marked.
b) Number of discharge points (ditches, pipes, etc. that convey wastewater from the property): 1
c) Volume of discharge per each discharge point (in GPD): 1,500
7) Discharge frequency: [Required by 15A NCAC 02H .0105(c)(1)]
a) The discharge is: ❑ Continuous
® Intermittent - Describe when the discharge will occur:
The DPE Mobile Treatment Unit (MTU) is trailer -mounted and has been designed to alternate on a
rotating schedule between this site and the Speedway 7971 facility located in Conover, NC. The
anticipated schedule of operation will be 3 months on -site and 6 months off -site, with adjustments as
needed (if applicable)
b) What is the source(s) of contamination (i.e. gasoline, diesel, solvents, etc.)?: Diesel fuel
General permits may be obtained for gasoline and/or heavy fuel contamination. An individual permit apphcation must
be submitted for sites contaminated with other constituents such as solvents and pesticides.
c) Is free product present?
® Yes - Product storage tank and an oil/water separator are required. Free product is defined as any
measurable accumulation of 1/81' or more in a well or floating on surface water.
❑ No
Page 2 of 5 Revised 911113
NCG510000 New Application
8) Treatment system components: [Required by 15A NCAC 02H .0105(c)(3)]
Please note: Final design specifications for the actual system that will be installed must be included in this section.
Do not submit this application if only bid specifications are known.
Check all of the following that apply:
® Oil/Water Separator ® Air Stripper ® Carbon Adsorption ® Filters
❑ Other:
a) If an Oil/Water separator is present, please provide the following information:
i) Rated flow capacity of the unit (in GPM): 20
ii) Volume of unit (gal): 155
iii) Detention time (min): 7.75
iv) Free product disposal method: Gravity drain to external 500-gallon AST
b) If an air stripper is present, please provide the following information:
i) Rated flow capacity of the unit (in GPM): 50
ii) Air provided for stripping (in CFM): 400
iii) Air to Water ratio: 8: 1
iv) Number of trays (if applicable): 4
(Removal efficiencies for all chemicals of concern should be included in this submittal. Efficiencies should
be expressed as a percentage, i.e. 98% or 0.98) 99 9%, Attachment B
c) If carbon adsorption is present, please provide the following information:
i) Rated flow capacity of the unit(s) (in GPM): 40
ii) Number of carbon units and arrangement if number exceeds one (i.e., in parallel or in series): 2 series
iii) Pounds of carbon in each unit: 200
iv) Specify carbon breakthrough time: 290 months
(The method used to calculate breakthrough time must included in the submittal.) ? Attachment B
d) If filters are used, please provide the following information:
i) Rated flow capacity of each unit(s) (in GPM): 100
ii) Arrangement of particulate filters within the system: ❑ Parallel ® Series
e) Solids disposal method: N/A
fl If other components to be included, please specify: N/A
9) Receiving waters: [Required by 15A NCAC 02H .0105(c)(1)]
a) What is the name of the body or bodies of water (creek, stream, river, lake, etc.) that the facility wastewater
discharges into? If the wastewater discharge is to a separate storm sewer system (4S), name the operator of the 4S
(e.g. City of Raleigh). MS4 operated by NCDOT; discharge point from MS4 is to Kerr Branch;
approval from NCDOT to discharge into the MS4 provided as Attachment E Attaahme
b) Stream Classification (i.e. WS-IV, C, SA, etc): C
10) Alternatives to direct discharge:
[Evaluation required by G.S. § 143-215.1(b)(5)(a) and 15A NCAC 02H .0105(c)(2)]
Address the feasibility of implementing each of the following non -discharge alternatives:
a) Connection to a Municipal or Regional Sewer Collection System
b) Subsurface disposal (including nitrification field, infiltration gallery, injection wells, etc.)
Page 3 of 5 Revised 911113
NCG510000 New Application
The alternatives to discharge analysis should include boring logs and/or other information indicating that a subsurface
system is neither feasible nor practical as well as written confirmation indicating that connection to a POTW is not an
option. It should also include a present value of costs analysis as outlined in the Division's "Engineering Alternatives
Analysis (EAA) Guidance Document". Attachment D
Additional Application Requirements:
For new or proposed discharges, the following information must be included in triplicate with this application or it will be
returned as incomplete; per 15A NCAC 02H .0105(c).
Attachment A a) 7.5 minute series USGS topographic map (or a photocopied portion thereof) with discharge location clearly indicated.
Attachment A ;, b) A site map clearly tracing the pathway of the discharged water from the site to its discharge point, if the discharge is
not directly to a stream.
Not Applicable; c) If the discharge will cross or empty into any easements, right-of-ways, or other public/private property, i.e. DOT,
utilities, ditches, etc., before entering the permitted discharge stream, proof that approval was received from the
appropriate landowners and/or agencies must be provided prior to issuance of the permit.
Not Applicable d) If this application is being submitted by a consulting engineer (or engineering firm), include documentation from the
applicant showing that the engineer (or firm) submitting the application has been designated an authorized
representative of the applicant; per 15A NCAC 02H .0138(b)(1).
[_Attachment B e) Final plans for the treatment system (if application is for a new or modified permit). The plans must be signed and
sealed by a North Carolina registered Professional En ig neer and stamped -"Final Design -Not released for
construction;" per 15A NCAC 02H .0139.
Attachment B fl Final specifications for all major treatment components (if application is for a new or modified permit). The
specifications must be signed and sealed by a North Carolina registered Professional Engineer and shall include a
narrative description of the treatment system to be constructed, per 15A NCAC 02H .0139.
[ Attachment A g) Site map identifying the location of the monitoring wells, the recovery wells, and the treatment system unit.
Attachment C h) Analytical monitoring data which sufficiently characterizes the type and concentration of contaminants on site. This
includes a listing of any chemicals found with the maximum observed concentrations reported. The data provided
must be no older than one year prior to the date of this application. At a minimum, the following parameters must
be reported: Benzene, Toluene, Ethylbenzene, Xylene, Lead, Phenol, MTBE, and 1,2-Dichlorethane.
*Note: Groundwater contamination at the site is associated with a previous release of diesel fuel; as such, dissolved -phase
groundwater contamination at the site is minimal and, therefore, remediation efforts have focused primarily on free -phase product
recovery. A summary of recent and historical groundwater analytical data is provided in Attachment C.
Page 4 of 5 Revised 911113
NCG510000 New Application
CERTIFICATION
I certify that I am familiar with the information contained in this application and that to the best of my knowledge
and belief such information is true, complete, and accurate.
Printed Name of Person Signing: 3Oh ri Ad Wte,
Title: Q eogfoRhte, GJVi*brJr1W4V-1
(Please re ' 5A N0,C 02 106 for authorized signing officials)
(Signature of A plicanl) (Dale Signed)
North Carolina General Statute 4 143-215.613 provides that:
Any person who knowingly makes any false statement representation, or certification in any application, record, report,
plan, or other document filed or required to be maintained under this Article or a rule implementing this Article; or who
knowingly makes a false statement of a material fact in a rulemaking proceeding or contested case under this Article; or
who falsifies, tampers with, or knowingly renders inaccurate any recording or monitoring device or method required to be
operated or maintained under this Article or rules of the Commission implementing this Article, shall be guilty of a Class
2 misdemeanor which may include a fine not to exceed ten thousand dollars ($10,000). 18 U.S.C. Section 1001 provides
a punishment by a fine or imprisonment not more than 5 years, or both, for a similar offense.
This application must be accompanied by a check or money order for $100.00 [per G.S. 4143-215.3(a)(1b)1
made payable to:
NCDENR
Mail this application and one copy of the entire package (with check) to:
NC DENR / DWR / Water Quality Permitting Section
1617 Mail Service Center
Raleigh, North Carolina 27699-1617
Attn: Charles Weaver
Final Checklist
This application will be returned as incomplete, as allowed by 15A NCAC 02H .0107(b), unless all of the
following items have been included:
❑ Complete application with all supporting documents (plus one copy of entire package)
❑ Check or money order for $100.00, payable to NCDENR
❑ 3 copies of county map or USGS quad sheet with location of facility clearly marked on map
❑ 3 sets of plans and specifications signed and sealed by a North Carolina P.E. (if new or modified permit)
❑ Thorough responses to items 1-I I on this application
❑ Alternatives analysis including present value of costs for all alternatives
Note: The submission of this document does not guarantee the issuance of an NPDES permit.
ATTACHMENT A
SITE MAPS
1. PROPERTY LINE FROM IREDELL COUNTY GIS PARCELS FILE, JULY 2010. SCALE: 1 :12,000
2. SHEPHERDS, NC DIGITAL RASTER GRAPHIC FILE, US GEOLOGICAL SURVEY.
SCANNED FROM 1:24,000-SCALE USGS TOPOGRAPHIC MAP: SHEPARDS, NC, 2016. 77= Feet
3. INSET MAP DIGITAL DATA FROM 2002 NATIONAL TRANSPORTATION ATLAS,
BUREAU OF TRANSPORTATION STATISTICS, WASHINGTON, D.C. O 1,000 2,000
DRAWN
DATE:
Mid Atlantic
TOPOGRAPHIC SITE MAP
SPEEDWAY #7976
BY: EBA
NOVEMBER 2017
DRAFT
CHECK:
JOB
00 OOOR1167.28
A E-,.-,-ul $0-o-
(FORMER WILCOHESS #350
ENG.
GIS NO:
TROUTMAN, NORTH CAROLINA
CHECK:
01 G-R1 167.28-1
APPROVAL:
DWG NO: 1.1
oMW-19
GRASS
24" TRAFFIC RATED
H-20 VAULT PROPANE
1 TANK
/
0Mw-a
CURB
x
/
SYSTEM FENCING
WITH 12' GATE
/
BUILDING
LEGEND
e MW-1
MW-10d
i
OMW-18 VENT PIPE V MW-12
DIESEL FUEL - _x
USTs
K MW-5 r , r , r , GASOLINE
jo I I I I I I I I I UST,
I I I 1 L JL JL J
1 CONNECTION TO O 1 Q I j Q j-�_°��_��-$����
] EXISTING STORM 1 C 1 L,dpi LLa=
SEWER ASPHALT 4bMW-4 L J �L�e MW-g°— M° 11 OOLER III
CATION UNCONFIRMED III
DPE11 DPE07
MW-1
DPE10
(COVERED 0 DPEO DPE 3i I
MW-3 MW-2 � IIII
/ DIESEL
DI S END RL DPE09 DPE05 DP 2i MW-16 OMW-15 I IIII I I I
CANOPY la MW-14 i I 111 I I I
/ (COVERED) DPE08 ASPHALT
— MW-20-�'EDPE01� T� - I IIII
/ I / l-WILCO GASOLINE 4jam357 I IIII I I
II
DISPENSEP-y I I I
— — � ISLAND
TRUCK PARKING MW-22
/ EDGE OF I I CJ I
/ CONCRETE PAD /L-- — J
CANOPY I
/ 0 MW-9 MW-100 emw-18 I
® MW-10d
/ 0 MW-23
/ ENTRANCE
I
MW-17,0
I
II
TRUCK PARKING � MW-25 - -
/CURB
(ASPHALT)
BUILDING
MW-24 GRAVEL
PARKING
LOT
—x—x—x—
—s—s—s—
MONITORING WELL LOCATION
DEEP MONITORING WELL LOCATION
DUAL PHASE EXTRACTION WELL (BY OTHERS)
REMEDIAL SYSTEM UNDERGROUND UTILTY TRENCH
FENCE
EXISTING STORM SEWER (TO KERR BRANCH)
ESTIMATED LOCATION OF PRODUCT PIPING
SUBJECT SITE PROPERTY BOUNDARY
0 MW-26
NOTES:
MONITORING WELLS MW-14 AND
MW-21 COVERED WITH ASPHALT
DURING PREVIOUS PAVING ACTIVITIES
0 50'
SCALE: 1 "= 50'
N
N
�
I
O
N
r
W
O
z
O
O
I
�
O
O
O
z
z
O0
U
0
Y
Y
U
U
U
�
w
w
_
W
=
U
U
Z
W
Q
Z
Z
ow
�r
zr
d
0m
1 om
wm
Qm
(%)
J
Ln
rn
W z
0 N J
ZO
_ � D_
r` Q
a-
zU =
0 > �
Q 3 O
1.- 0
O
0 a- Lj J Q
� V)
O
w g Of
>_ O
Vc
0
0
ro
ct a.a)
E
o
Q 'L
W
06
•111111111111111 y
w
C
ao
w
W
0
z
W
W
L L-
W
' CBDI 2 2. 4
�aNL• �� 4 — TOP 92
I.E. 9T9.29
77 I.E. 9T8.84
MAP NO SCALE
System
0
=LOOP= - q N-705.440.95
E-1,44a.358.23
%%
RN
rnr
.U�pN01P rl //•\
( a
76 C Existing
Underground
Storm Sewer
WN
loo
4 \
0
` �
�v • gje 4i
sr P U,m.�r.
'J\J
j Proposed discharge to /
existing underground a \\✓ ?4 0
4� M-244 6 I storm sewer ;Ac 'ti >F gmN N�
2DNED / $
I DEED
O/W S
\
`\
xIs mg epara or
Discharging to Existing
\
\\`\
\\
Storm Sewer
1
V1.
�'
00•/
b
6�
tp�µap6N�
ss
/
WC,
DON"
AL 90FORTH
ZCIED: G@
/
6
\$ /
1i /
/
4740-93
LEKAND-19/3
JT.. N ALE JR.,
JOVN W. W. NEKANDER
N
\
\
IM4-902
ZONED OB
/
IRS
\
7NF Sl5EC1 PROPERTYY B 11OT M A
SPECy IN7AM MEA' AS SIDWN ON
/
\
\
\
!AD/FM ROOD 1191DNCE RATE NAP
00WMIT PAKEL MUmI 370313 01750
UTECINE DAF WY /0. 1T9p,
/
/
\
\
\ \
NOTES
1. PROPERTY IS ZONED RUl(CENHRA W(i1WAY BUSINESS)
2. WATER ! SANITARY SEWER WILL BE FURMSHED BY THE TOWN OF TROUTMAN
3.
ULHES9HLWSUER0R0
\
F]LL BENONOTED.
4. 1OWNFCT.LCCROWR UIN0.
5. THERE IS A 10� 0RA9UG£ k UTUTY EASEMENT. FRONT k REAR UNE,
W"SI EACH IIR.
SIRJECT PROPflRY DOES LIE WITHINONRY. 2000' OF NCGS MONUMENTS,
7. DUINPSIER UICLO5ITRE WILL BE 1KSONRY.
Du
/
112AM08 Lq.R
2.'3M *am
go
nderground
:orm Sewer
RESTAURANT PARKING
SEA • 1 SPACE PER 2 SEATS - 30 SPACES
TOTAL REQUIRED PAORIO SPACES - 39 SPACES
PRaAnEo-
CONCRETE WHEEL STOPS
VAN
TYPICAL PARKING
\ \
TYPICAL PARKING
\ \
<
R
\
� i
1
\
T
1
ism- I
4r yI
�L Ar rio., �ql
I I
I' —1_J
.v w+a • ROAD n
TMICIL NND/I 9EIVACK DOM
SETBACKS,
PROPERTY IS SMIECT TO A 30' FRONT. 10' SOL 20' K -.
20' SIDE STREET MINIMUM BUILDING SETBACK LML t A
. _ MWXMIW BULaw-mma OF 40„POE.Iwi40
ZONING FOR PROPERTY ZONED. 08.
i
Discharge to
Kerr Branch \
C \
G? \
N <O
s
LEGEND.
HYD - FIRE NYORAR
FOC - FIBER OPTIC CABLE
Ei - EXISTING IRON PIN
PS - PON PIN SET
RW4 - RIGHT OF WAY MONUMENT
OPL - OVERHEAD POWER LINE
F'P - POWER POLE
SP - SERVICE POLE
SI - STEEL I -BEAN
TR - POWER TRANSFORMER
ER - ELECTRICAL RECEPTACLE
TP - TEIEPNCNE PEDESTAL
LP LIGHT POLE
WM - WATER MFTER
Co - CATCM BASIN
FP - FLAG POLE
W^/ - WATER VALVE
SM - BENCHMARK
I - UNI WK D POINT
UMSL - MIN MA M BUIDNG SETBACK LINE
SCO - SEWER CLEAN OUT
912M
99 90A19
NUR: 20 .09
GRAPHIC SCALE
( IN FEET )
I inch - 40 It
sry = _
33292 _
(3 � N
Z 00
cDO
C� (V N
Z
00
>a)z
(n � J l�
X J .�
W m W L�.I
Z
wO
ll,
DRAWN CSr
CHECK xc
DATE oe-la-CAT
SCALE
PNpJ_ rasa.
SITEET
C-1
ATTACHMENT B
NARRATIVE DESCRIPTION AND FINAL
PLANS/SPECIFICATIONS
Mici Atlantic
Engineering & Environmental Solutions
Dual -Phase Extraction System
Narrative Description
409 Roge -s Vic w Cuu: t
Ralc+git. NC 27610
office 919.250.9916
1acsinnlu 919.2509950
MAAONLtNE.COM
Groundwater and free -phase petroleum hydrocarbons will be recovered from each of the
extraction wells using a liquid ring pump and associated piping/trench lines, prior to being
separated via the process discussed below:
• Extracted groundwater and free -phase petroleum hydrocarbons will be recovered
from the extraction wells and transferred into a phase -separator tank. Pilot studies
have indicated that groundwater recovery will produce up to 0.9 gallons per minute;
It Groundwater/free product will be transferred from the phase -separator tank to an oil -
water separator system via a transfer pump rated at 10 gallons per minute. The
system will shut down in the event the high -high level float switch located inside the
phase separator is activated;
• Recovered free product from the oil -water separator system will be gravity -fed to an
external product tank; which will be monitored and pumped out on an as -needed
basis by a certified disposal contractor, prior to transportation off -site for disposal.
The external product tank will be equipped with a high -high level float switch to shut
the system down in the event recovery exceeds the allowable capacity of the tank;
• Groundwater from the oil -water separator system will be pumped to an air stripper
via a transfer pump rated at 20 gallons per minute. The system will shut down in the
event the high -high level float switch located inside the oil -water separator system is
activated;
• Recovered groundwater will then be pumped from the air stripper through granular
active carbon vessels with a transfer pump rated at 20 gallons per minute. The
system will shut down in the event the high -high level float switch located inside the
air stripper is activated;
• The air stripper will also be equipped with a pressure monitor. In the event of low
pressure conditions are identified (indicating blower failure), the system will be shut
down; and
• Groundwater treated using the methods described above will be directed through a
flow meter and discharged to the on -site storm sewer, which will ultimately discharge
to Kerr Branch. The system is designed to run continuously with telemetry notification
in the event that the high -high level or pressure alarms are tripped and the system is
shut down.
The DPE Mobile Trailer Unit (MTU) Layout and Process & Instrumentation Diagram are
attached to illustrate the system operation as detailed above, along wit i detailed equipment
specifications for reference.
Ai.,
.,Ih ZI
- O (, r
.s`•f 0^lt li L�,�e4• � .�
2
O
D
0
O
D
m
m
1
m
D
m
z
v
_
m
�m
O Zr
14*
Dd O
r
TO ATMOSPHERE
sIy
--1
m
U) (rn
r
5 '
>
M
n
<D
_
�x
i
m
o
O
m
m
I
AIER, P.E.
RIVE
CI ENT
SPEEDWAY LLC
SHEET TITLE
PROCESS AND INSTRUMENTATION DIAGRAM
NO. REVISION
500 SPEEDWAY DRIVE
DUAL PHASE EXTRACTION SYSTEM
PROJECT TITLE
:R022633
ENON, OHIO 45323
SPEEDWAY#7971
1343 ROCK BARN ROAD
CONOVER,NC
DATE
1AIER, P.E..
WENT
)RIVE
SPEEDWAY LLC
93
500 SPEEDWAY DRIVE
3
ENON, OHIO 45323
O ATMOSPHER
SHEET TITLE
NO. REVISION
PROCESS AND INSTRUMENTATION DIAGRAM
WATER TREATMENT SYSTEM
PROJECT TITLE
SPEEDWAY #7971
1343 ROCK BARN ROAD
CONOVER,NC
DATE
Carbon Uusage
Pumping Rate (gpm) 1.04
1/n K
Xylene
0.19
Toluene
0.44
Ethyl
0.79
Benzene
0.5333
Calculation of Carbon Breakthrough Time
(anticipated flow
rate)
Pumping Rate (pgd)
1497.6
amout addorbate per unit weight of carbon
CO*
CO* Ce**
F**
(x/m)CO (x/m)Ce
CUR CUR
ug/I
mg/L ug/I
mg/L L/d
mg/g mg/g
g/d Ib/d
0
0
5669
0
0
5669
0
0
5669
85
13.13
0.01313
1
0.001
5669
37.3155 22.87805
1.844011
26.1
0.293
0.000293
1
0.001
5669
0.727884 1.249225
-5.509968
53
1.61
0.00161
1
0.001
5669
0.329358 0.226087
10.S0639
50.1
2.22
0.00222
1
0.001
5669
1.925962 1.25874S
3.593387
Total
10
Carbon Amount per Vessel (lb):
# of Carbon Vessels:
Changeout(d)
Months
CUR CUR
Ib/1000 L Ib/1000 Gal
0.0041 0.0007156 0.002708884
0.0121-0.002138-0.00809424
0.0231 0.0040773 0.015434063
0.0079 0.0013945 0.005278747
0.023
200
1
8713
290.4308953
May 5th, 2017
PRODUCT RECOVERY MANAGEMENT
Mr. Jimmy Clark
Mr. Mike Fox
Town of Conover, North Carolina
PO Box 549
Conover, NC 28613
RE: Speedway Remediation site
Mr. Fox.
Thank you for discussing the Speedway project with me a few days ago which is administered
by Mid -Atlantic Environmental and the NCDEQ for approvals. PRM was contracted by
Speedway to manufacture the remediation system for the cleanup. We have been in this
business for 28 years now and this is our primary business. PRM is a UL shop and we
manufacture remediation systems using the latest in safety requirements. PRMs UL
certifications is not only controls but also for full packages. Safety is always of utmost concern
in what we do.
My client Speedway and Mid -Atlantic have asked me to explore options for the discharge
requirements of this site and they have asked our professional opinion of installing additional
downstream vapor monitoring. We have advised them that our recommendation is that effluent
vapor monitoring is very atypical and we have never had a request to do so after a system with
such robust and effective treatment.
This system uses dual phase extraction which will remove 100% of all free vapor from the
influent stream. Residual free NAPL can exist in the oil water separator. No residual NAPL can
exist in the Air Stripper which effectively removes >99.9% of all solubilized compounds which
become extremely diluted vaporized materials where the exhaust of the air stripper will typically
see vapor concentrations in the ppb range on the effluent. At this point, water is left with only
potential for very low ppb range (not ppm range) materials in the water. At this point, Carbon
Absorption reduces ppb range materials to absolute zero. Carbon beds are in series and are
monitored monthly for breach between vessel 1 and vessel 2.
My request is to reconsider your request for effluent vapor monitoring as we feel the level of
protection and safeties is extreme and the potential for effluent vapors does not exist. In the
event the client cannot forgo the requirements, they have advised me that they will pursue
alternative methods of water disposal. I hate to see not efficient measures taken so we request
you guys to accommodate our customers needs if possible.
Thank you for consideration.
Mel Phillips
President
Product Recovery Management, Inc.
Cc: ChuckHoffman, Mid -Atlantic
SVE Inlet Manifold
• 4" x 2" Sch 80 PVC manifold with 3 legs
• Each of the three legs will consist of the following equipment:
o Vacuum Gauge
o Sample port
o Rotometer
0 2" Ball valve
0 2" x 12" Clear sight tube
o 2" Male x NPT Cam locks on exterior
Dual Phase Extraction
• Dekker VMX0303K liquid ring vacuum pump
0 20 Hp 480V 3 phase motor
o Electric Motor TEFC, 230/460 Volt, 3 phase, premium efficient.
o Flexible coupling
o Fabricated steel baseplate
o Discharge separator -reservoir with 5-stage air/oil separation, including
coalescing filter
o Seal -fluid isolation valve, Y-strainer, Solenoid valve 24V DC
o Separator drain valve, and sight -level gauge
o Temperature RTD for discharge temperature indication and high temperature
protection
o Air-cooled, heat exchanger
o Inlet check valve
o Set of hydraulic hose seal -fluid line
o Full charge of Vmaxol sealing fluid
o High level fluid switch
o Low level fluid switch
o Discharge temperature gauge and sample port
o Itrans2 LEL meter
o Discharge stack to atmosphere
Moisture Separator
• PRM Model MS120 Moisture Separator with a clean out port
• Intrinsically safe Three float stem mounted in the sight tube
• Manual drain valve
• Inlet Vacuum gauge
• Inlet Sample port
• 2" Gate valve and Solberg filter/silencer for manual dilution
• Kunkle vacuum relief valve
• MS Pump Out - Continental progressive cavity pump coupled to 1 Hp, 480V, 3 Ph, Class
I Divll rated motor
o Discharge of pump plumbed w/ union, check valve, wye strainer, ball valve,
pressure gauge and sample port
o Inlet includes isolation valve
o Discharge line will plumb to the Oil Water Separator
OWS-20 with Integral Sump
• PRIM model OWS-20 Oil Water Separator with integrated sump
• 2" inlet/outlet
• 2" adjustable oil skimmer, outlet on either side
• Air vent
• 2" wide gasketed lid w/ easy turn retainers
• Intrinsically safe Three float stem mounted in the sight tube
• Gravity drain line to exterior to be connected to Product Tank.
• 500 Gallon steel product tank with high level cut off switch
o See option for upgrading tank to a double wall tank for extra protection
• Pump Out - AMT Model 5473-98 centrifugal pump coupled to 3/4 Hp, 480V, 3 Ph motor
o Discharge of pump plumbed w/ union, check valve, wye strainer, ball valve,
pressure gauge and sample port
o Inlet includes isolation valve
o Discharge line will plumb to the filter Diffuser
Low Profile Air Diffuser
• PRM model DA-50 High Efficiency Diffused Aerator
• GAST R6340R-50 regenerative pressure blower
• Pressure transmitter
• Intrinsically safe Three float stem mounted in the sight tube
• Sump drain
• Pump Out - AMT Model 48913-95 centrifugal pump coupled to 1.5 Hp, 480V, 3 Ph motor
o Discharge of pump plumbed w/ union, check valve, wye strainer, ball valve,
pressure gauge and sample port
o Inlet includes isolation valve
o Discharge line will plumb to the filter Bag Filter/Carbons
Bag Filtration
• PRM Stainless Steel Pressure Bag Filter housing, 8" Dia x 30" Long containing the
following
• 2" 1/0, 100 psi rating, 100 gpm rating
• SS Strainer basket sized for #2 trade size bag
• Case (25ct.) of 25 Micron Bag Filters
• Ball valves on inlet and outlet
• Pressure gauges and Sample ports
Carbon Polish
• (2) PRM model HP-200 carbon vessels
o Each filled with 200 Ibs of reactivated carbon
• Ball valve, pressure gauge and sample port on inlet of each, and outlet of 2nd in line
• Camlock and hose connections between units and plumbing to backwash manifold
• Backwash manifold as per specification drawings
• Check valve on discharge piping to the exterior
• Totalizing flowmeter on final discharge
Treatment Trailer
8.5' x 24' trailer, with 2.5' tongue, steel tube wall construction 16" o/c walls, 24" o/c roof, 6" tubular
main frame, 3/4" PT plywood treated floor, 0.030 alum exterior, galvalume roof, W plywood interior
wall liner and luan ceiling liner, insulated walls and ceiling, lockable hasps on doors , double rear
door, single front side door, dual 5200 lb torsion axles w/ electric brakes, running and brake lights,
std 7 way plug for lights and brakes, radial tires, factory supplied door hold backs.
• Trailer will be insulated with sound attenuation insulation
• Wall vents throughout for proper ventilation.
• Trailer to be rated and wired for Class 1 Div II for SVE location
• LEL Itrans2 meter installed inside
• Thermostatically controlled hazardous location exhaust fan with fan guard for
SVE side, exterior louver, exterior finger guard, and sound hood.
• Hazardous location fluorescent lights w/ switch
• Thermostatically controlled hazardous location convection heater
• Partition wall to separate controls and non-haz equipment
• Standard lighting, ventilation and heating in control/compressor room
• Non slip epoxy liner on floors and up the side walls
• Rain gauge on exterior
• I -Bolt or U-Clamps provided for others to tie trailer down
• Provide heavy duty jacks for leveling of trailer installed on all corners
• Includes full fabrication of treatment system, including plumbing, electrical, and
thorough testing as well as labeling.
Control Panel
• NEMA 4 3rd Party Listed Industrial Control Panel
• Hand -Off -Auto switches
• Green running lights and red alarm lights
• Reset button
• Intrinsically safe relays for all level switches
• Distribution block and circuit breakers mounted inside of the enclosure
• Contacts and relays
• Motor starters with thermal overload and circuit protection
• Transmitter Installation and programming
• VFD for SVE & AS motor
• EOS Research PLC Platform with telemetry
• Cradlepoint Router and external antenna with booster which will be preconfigured and
pre-programmed for site connectivity. Note that router remains the property of PRM if
service is disconnected. This is a high -end commercial grade M2M router. In the event
router is not returned, a $550.00 payment would be due to PRM.
• Hi Speed 4G/LTE wireless with 3G rollover. Includes 1 year of service. PRM provides
Cradlepoint cloud management service at no additional fee. This allows PRM to provide
remote diagnostics and intrusion management. Includes hardware s
• GFCI all weather outlet located on outside of building
• Cyber Power 825VA UPS battery backup/surge protector
• System Voltage Phase monitor for primary power protection.
• Provide surge suppression for all 4-20mA and discrete 1/0 to the PLC system.
System Load Center
• PRM has placed all circuit breakers in a 100 amp load center with main breaker. The
load center serves to minimize risk of Arc Flash or Shock hazards associated with
operations and troubleshooting of the system.
• Individual circuit breakers for branch circuit protection of individual motors and loads
• Breaker locks will be provided for each breaker in the panel.
• Breaker panel is properly grounded and bonded and will comply with all provisions for
grounding as specified in the 2011 NEC.
• Main power will enter load center and all distribution of power shall be made from here.
MISC
• Delivery will be via truck, PRM will unload and set system in place as long as it is truck
accessible
• Includes 1 year warranty
• Includes (2) O&M manuals
• Provide UL certification listing of the entire package. Include di -electric testing of the
entire package and application of the UL listing. PRM recommends for ease of
permitting. The certification process adds validity and compliance and mitigates liability
for all parties involved.
• Includes two days on -site startup and an additional one day for training and
troubleshooting 2 weeks after start up
PRM Gauges
PRM Pressure and Vacuum Gauges:
Available for immediate shipment for all
Environmental and Industrial applications.
Absolute Quality:
Useful for Air and Water Applications
Liquid Filled and Dry Available
• Liquid Filled Gauges contain a glycerine
filling to dampen the effects of vibration
and extend the life of the gauge.
Dual Scale readings:
PSI & BAR, Hg & BAR, WC & PSI, WC & Hg
Features:
• 2" and 2.5" Dials
• Stainless Steel, Chrome, and Plastic Cases
(Stainless Steel Resists Rust and Corrosion)
• Brass or Stainless Steel Internals and
Connections
• Accurate Readings: +/- 1.5%
• 1/4" (M) NPT Back Mount or Bottom Mount
Connections
)
Bottom
Mount
Connection 7
fl
t
ck Mount
Connection
M PR
jl"Mi&
ir'
PRODUCT RECOVERY MANAGEMENT
Absolute Quality is our Goal... Genuine Service is our Habit!
w IN
io
�s
30
PRM offers Industrial Quality Gauges for
sale at competitive prices.
Not sure which gauge is right for your
project? Our PRM Genuine Service
provides a knowledgeable and friendly
sales team to make sure you get the right
part and are satisfied with PRM products.
(888)TREAT— IT (888) 873-2848
sales@prm-net.com
Product Recovery Management, Incorporated
(888) TREAT -IT
88_8-87.3-2848 • 919-957-8890 • www.prm-net.com • sales(a)-prm-net.com
Butner, NC • Webster, NY • Lakeland, FL
* Actual equipment specifications may vary. Please contact Product Recovery Management, Inc. for additional details. P-05
PRM Vacuum Gauges
9���
PRODUCT RECOVERY MANAGEMENT
2.5" Dial
-30-01-1g, -1-0 BAR
Bottom Mount
Stainless Steel Case
Stainless Steel Internals with
Brass Connector
1/4" NPT
PRM #035-3
2" Dial
-30-0 inNg, -1-0 bar
Back Mount
Steel Case
Brass Connector
1/4" N PT
PRM #045-1
2.5" Dial
-160-0 "WC/-6-0 psi
Bottom Mount
Chrome Case
Brass Internals and Connector
1/4"NPT
Absolute Quality is our Goal... Genuine Service is our Habit!
PRM #025-22
2.5" Dial
-30-01-1g, -1-0 BAR
Back Mount
Stainless Steel Case
Stainless Steel Internals
with Brass Connector
1/4" NPT
'C- -7 inNg
Vacuum
PRM #045-3V
2.5" Dial
0-100 "WC/ 0-7 inNg
Back Mount
Chrome Case
Brass Internals and Connector
1/4" NPT
PRM #045-4
2.5" Dial
-160-0 "WC/-12-0 inNg
Back Mount
Chrome Case
Brass Internals and Connector
1/4"NPT
* Actual equipment specifications may vary. Please contact Product Recovery Management, Inc. for additional details. P-05(4)
PRM PVC Valves and FittingsAM.
PRODUCT RECOVERY MANAGEMENT
Absolute Quality is our Goal... Genuine Service is our Habit!
PRM has PVC Valves and Fittings for your Project Needs. Because of our Industry Buying
Power, PRM can get PVC for less, and in turn we pass on the cost savings on to you.
A wide selection of Schedule 80 PVC Valves and Fittings and Schedule 40 PVC Fittings are
kept in stock for quick delivery from our warehouse to your project site.
Butterfly Valve
Handle Type, ANSI
219, 3", 490, C„
True Union* Ball Valve
ANSI
1 /2" 3/4", 1 " 1-1 /4", 299, 39, 4"
Compact Ball Valve
Light Type, ANSI
3/4", 1 ", 1-1 /4"
2", 3", 4"
Single Union Ball Valve
ANSI
2„
True Union* Ball Check Valve
ANSI
1 /2", 3/4", 2"
*The term true union means that the carrier or main part of the valve can be removed from the
piping system and be repaired or replaced.
Product Recovery Management, Incorporated
(888) TREAT -IT
888-873-2848 - 919-957-8890 - www.prm-net.com - sales(cDprm-net.com
Butner, NC - Atlanta, GA - Webster, NY - Raymond, NH - Lakeland, FL
* Actual equipment specifications may vary. Please contact Product Recovery Management, Inc. for additional details. P-16
PRM PVC Valves and Fittings •
PRODUCT RECOVERY MANAGEMENT
Absolute Quality is our Goal... Genuine service is our Habit!
PRM has PVC Valves and Fittings for your Project Needs. Because of our Industry Buying
Power, PRM can get PVC for less, and in turn we pass on the cost savings on to you.
A wide selection of Schedule 80 PVC Valves and Fittings and Schedule 40 PVC Fittings are
kept in stock for quick delivery from our warehouse to your project site.
Butterfly Valve
Handle Type, ANSI
219, 2-1/2,',3", 4", 6",8"
Gate Valve
Slip x Slip
2", 3", 4"
Butterfly
Valve,
Gear Type
6"
Product Recovery Management, Incorporated
(888) TREAT -IT
888-873-2848 • 919-957-8890 • www.prm-net.com • sales(Wprm-net.com
Butner, NC • Webster, NY • Lakeland, FL
* Actual equipment specifications may vary. Please contact Product Recovery Management, Inc. for additional details. P-16(2)
PRM PVC Valves and Fittings AN100
e
PRODUCT RECOVERY MANAGEMENT
Absolute Quality is our Goal... Genuine Service is our Habit!
PRM has PVC Valves and Fittings for your Project Needs. Because of our Industry Buying
Power, we can get our PVC for less, and in turn we pass that cost savings on to you.
Wide Selection of Schedule 80 PVC Valves and Fittings and Schedule 40 PVC fittings kept
in stock for quick delivery from our warehouse to your project site.
10 40
Union, ANSI Union, NPT Coupling 900 Elbow 450 Elbow
1", 1-1/4", 2", 3" 2" 1-1 /4, 2", 3", 4", 6" 1 ", 1-1 /4, 2", 3", 4", 6" 2",3", 4", 6"
Female Adapter Male Adapter
1", 1-1 /4, 2", 1 ", 2", 3",
3 4", 6„ 4„ 6„
Bell Reducer
Coupling
2" x 1 ", 2" x 1-1 /4"
End Cap
2"
Straight Tee Reducer Bushing
1", 1-1 /4, 2", 3/4" x 1 /2", 1" x 1 /2", 1" x 3/4", 1-1 /4 x 1 /2", 1-1 /4" x 3/4",
3", 4" 1-1 l4" x 1 ", 1-1 /2" x 1 ", 1-1 l2" x 1-1 /4" 2" x 1 /2", 2" x 3/4",
2" x 1 ", 2" x 1 /4", 3" x 2", 4" x 2", 4" x 3", 6" x 4"
Van Stone Flange
2„ 3„ 4„ 61$
Reducing Tee
2" x 1 ", 2" x 1-1 /4"
Product Recovery Management, Incorporated
(888) TREAT -IT
888-873-2848 - 919-957-8890 • www.prm-net.com - salesC&prm-net.com
Butner NC - Atlanta GA • Webster NY - Raymond, NH - Lakeland, FL
* Actual equipment specifications may vary. Please contact Product Recovery Management, Inc. for additional details. P-16
PRM Moisture Separators •
PRODUCT RECOVERY MANAGEMENT
Absolute Quality:
PRM Moisture Separators or Moisture
Knockout Tanks, are internally
manufactured and designed for high
efficiency. Moisture separators are
typically used with our Soil Vapor
Extraction, Dual Phase Extractors, or
Blower Stations. Our standard units are
designed for 300 to 2500SCFM vapor flow.
Features:
• Heavy Gauge Carbon Steel
• Epoxy Coated Interior
• UIV Resistant Coated Exterior
• FEA/CAD Engineering Design
• Tangential Inlet with Baffle Plate
• Integral Inline Demister
• Internal Centrifugal Isolation Ring
• Inlet Particulate Filter
• Clean Out Access Port Near Bottom
• Inlet and Outlet Pressure Gauges
• PVC Clear Sight Tube
• Drain Valve
• Inlet and Outlet Connections Either
Flanged or Threaded
Max Air Liquid
Model # Flow Capacity
(SCFM) (Gal)
MS-30 1 300 1 15
1 MS-60 1 400 1 30 1
MS-80 1 500 1 40
MS-120 1 750 1 60
1 MS-200 1 1100 1 100 1
1 MS-400 1 2500 1 400 1
Absolute Quality is our Goal... Genuine Service is our Habit!
** Options and Services **
• Skid Mounted
• Aluminum, Alloy, or Stainless Steel Construction
• Float Controls for Automated Level Control and
Alarm Conditions
• UL 508A and 698A (US and Canada) Control Panels
with Wireless Telemetry for Remote Monitoring
• Vapor Flow Measurement Devices
• Transfer Pump Packages with Instrumentation for
Fluid Processing
• Custom Integration Into New or Existing Systems
• Installation and Field Integration Services
• Startup and Operations Services
Contact PRM to Discuss Manufacturing a Custom
Moisture Knockout Tank for Your Project!
Product Recovery Management, Incorporated
(888) TREAT -IT
888-873-2848 • 919-957-8890 • www_prm-net.com • sales(cDprm-net.com
Butner, NC • Webster, NY • Lakeland, FL
* Actual equipment specifications may vary. Please contact Product Recovery Management, Inc. for additional details. E-07
Replacement Elements
35 - 6600 SCFM Flow Range
Small Elements
with Molded Endcaps
Features
• Pleated media for high dirt holding capacity
• Polyester: Reinforced with epoxy coated steel wire on both
sides of cloth
• Paper: Heavy duty industrial strength paper surrounded by
heavy gauge galvanized expanded metal
• 40 - 50% increased dust loading capacity with prefilter
(part number suffix P)
• Optimal surface area per given size
Technical Specifications
• Polyester: 99%+ removal efficiency to 5 micron
• Paper: 99%+ removal efficiency to 2 micron
• Temp (continuous): min -26°F (-15'C), max 220°F (104°C)
• Filter change out differential: 15-20" H2O over initial A P
Polyester Media Benefits
• Washable with lukewarm water & mild detergent
• Less maintenance due to longer durability
• Moisture resistant
• Handles hot air and oil mist from unload cycle of reciprocating/
piston compressor
..,4SOLBERG`
;IIIIIIIII�:
Compact & Large Elements
with Metal Endcaps
I� OD
I4 ID 0I
Paper Media Benefits
• Optimal surface area per given size
• Higher efficiency than many alternative media
• Cost effective
V SOLBERG.
Replacement Elements —up to 300 SUM flow
Replacement Elements
35 - 6600 SUM Flow Range
Note: Also available in wire mesh. Example part number for wire mesh: 230S Dimension tolerance + 1/4"
See Element Technical Data section for maintenance guidelines
Replacement Elements —up to 6600 SUM flow
Element Part
Number
Element SUM
Surface
Area ft2
•
• Endcap
PaperPolyester
Polyester
Paper
ID
••
HT
Features
235P
234P
570
8.3
22.8
4 3/4
7 7/8
9 5/8
M
335P
334P
800
12
34
4 3/4
7 7/8
14 1/2
M
237
236
550
8.6
22.6
4 2/3
7 3/4
8 1/2
GBN
239P
238P
570
11.5
52
4 7/8
9 1/4
10
GBN
245P
244P
880
14
35.5
6
9 3/4
9 5/8
GN I M
345P
344P
1100
22.1
57
6
9 3/4
14 1/2
GN
275P
274P
1100
19
45.4
8
11 3/4
9 5/8
GN
375P
374P
1500
28
68.1
8
113/4
14 1/2
GN
377P
376P
1825
50
125
9
14 5/8
14 1/2
GN
385P
384P
3300
50
140
14
19 5/8
14 1/2
GN
485P
484P
4705
75
200
14
19 5/8
21 1/2
GN
685P
--
6600
100
--
14
19 5 8
28 1 2
GN
Note: Most are available in wire mesh. Example part number for wire mesh: 244S Dimension tolerance ± 1/4
See Element Technical Data section for maintenance guidelines
Endcap Information Additional Media Options
M = Molded plastisol • 1, 4, 25, and 100 micron Polyester
B = Closed one end with bolt hole, open on other end • HEPA
G = Galvanized metal endcaps
N = Neoprene gaskets on open end(s)
• Stainless steel wire mesh
• High temperature Nomex
• Stainless steel Nomex reinforced by stainless steel
wire mesh & expanded metal
• Polypropylene
• Activated carbon
Note: Model offerings and design parameters may change without notice. See www.solbergmfg.com for most current offering.
Pressure and Temperature Limits
Models 912, 913, 918, 919: — Steam
3 to 250 psig [-20 to 17 barg] 1
-60' to 406°F [-51° to 208oC]
Models 912, 918: —Air/Gas/Liquid
3 to 300 psig [-20 to 21 barg]
-60' to 406°F [-51° to 208°C]
Models 913, 919: — Air/Gas/Liquid
3 to 900 psig [-20 to 62 barg]
-60° to 406°F [-51° to 208°C]
Vacuum — 6- through 29-inch HG
[200 through 1000 mbarg] — 300°F [149°C]
Maximum back pressure 50 psig [3 barg]
- threaded cap and packed lever
Applications
• Air/gas compressors - intercoolers -
aftercoolers.
• Liquid filled pressure vessels/systems
- ASME Section VI II (UV).
• Pressure vessels - containing gas, air,
liquid or steam. Including tanks and
receivers.
• Vacuum systems including pumps,
tanks and equipment.
• Optional materials for low temperature
- cryogenic applications.
• Oil/gas separators.
• Overpressure relief and protection
of pumps, tanks, lines and hydraulic
systems.
• By-pass relief or pressure regulation.
Models 912, 913, 918, 919 ASME Section Vill, Steam/Air/Gas/
Liquid, `UV' National Board Certified. Also available for Vacuum Service
Features and Benefits
• Available with soft seat.
• Threaded cap is standard (back pres-
sure tight).
• Hex on valve nozzle provides for
easy installation.
• Single control ring offers easy
adjustability of blowdown.
• Pivoting disc design corrects
misalignment and offers exceptional
performance.
• Guide to nozzle ratio reduces friction.
• Full nozzle design for optimum flow
performance.
• Threaded side outlet for piped off dis-
charge to eliminate fugitive emissions.
Model Descriptions
Model 912: Full nozzle design. SS warn
ring and disc with brass/bronze base.
Bronze/brass body and bonnet.
Model 913: Full nozzle design. Bronze/
brass body and bonnet. 316 SS trim
(base, disc and disc holder).
Model 918: Same as Model 912 except
resilient seat/seal. Superior 'leak -free' per-
formance.
Model 919: Same as Model 913 except
resilient seat/seal. Superior 'leak -free' per-
formance. Bronze body and bonnet. 316
SS trim (base, disc and disc holder).
Options
• Threaded cap. (Variation 01)
• Threaded cap with gag. (Variation 02)
• Plain lever. (Variation 03)
• Plain lever with gag. (Variation 04)
• Plain lever with vibration dampener.
(Variation 05)
• Packed lever. (Variation 06)
• Packed lever with gag. (Variation 07)
1. ASME standard valves for air or steam ser-
vice must have lift lever. For steam boilers
and generators.
Models 912, 913, 918, 919 ASME Section Vill, Steam/Air/Gas/ Liquid,
'UV' National Board Certified. Also available for Vacuum Service
Service Recommendations for Resilient Seat/Seal Materials
Seat/Seal Materials' Service Recommendation
Air, Anhydrous Ammonia, Butane, Carbon Dioxide, Diesel Oil, Ethyl Chloride, Ethyl Ether, Freons #11 and 12,
BUNA-N (-40° to 200°F) [-40° to 93°C]
Fuel Oil, Gasoline, Helium, Hydrogen Sulphide, Kerosene, Lube Oil, Natural Gas, Nitrogen, Oxygen (Gas),
Propane, Propylene, Sulphur Dioxide, Vinyl Chloride
Acetone, Air, Amyl Alcohol, Aniline, Benzine, Butane, Carbon Disulphide, Carbon Tetrachloride
Dowtherm 'A' and 'E', Ethyl Chloride, Ethylene, Ethylene Glycol, Ethyl Alcohol, Gasoline, Hexane,
VitoneA {-10' to 406`F) [-23° to 208'C]
Hydrogen Sulphide, isobutyl Alcohol, JP - 4 Fuel, JP - 5 Fuel, Kerosene, Lube Oil, Natural Gas, Naphtha,
Nitrogen, Propane, Propylene, Propyl Alcohol, Sulphur Dioxide, Toluene, Trichloroethylene, Turpentine,
Water, Xylene
Silicone (-100° to 406°F) [-73° to 208°C1
Air, Helium, Nitrogen, Oxygen (Gas)
Ethylene Propylene (-70° to 400°F) [-57° to 205°Cj
Steam, Hot Water
Air, Anhydrous Ammonia, Butane, Butyl Alcohol, Castor Oil Denatured Alcohol, Ethanol, Ethyl Alcohol,
Neoprene (-45° to 300°F)[-43° to 149°C1
Freons (12, 13, 14 and 22), Glycols, Natural Gas and Silicate Esters
s -
1. These recommendations are a guide only.
For the final selection of the proper material,
your experience with available elastomers of
various lading fluids should be considered.
Modell Orifice Connections
Number ANSI Standard
Inlet Outlet
Maximum Set Pressure
psig [barg]
912-9184 913-9195
------ ---
A
Dimensions, in [mm] -- ----
B C C
Plain Threaded
Lever Cap
-
C
Packed
Lever
Approx.
Weight
lb [kg]
9'BDC D 1/2" [12.71 3/4" [19.01
300 [20.71
900
[62.11
23/8
[601
15/a
[411
83/8 [2131
71/4
[1841
9 [2291
3 [1.4]
9"BDC D 112" [12.71 1" [25.41
300 [20.71
900
[62.11
231a
[601
15/8
[411
83/6 1213]
71/4
[184]
9 [229]
3 [1.4]
9'BDD3 D 3/4" [19.01 3/4" [19.0]
900
[62.11
23/8
[601
15/8
[41]
83/8 [213]
71/4
[1841
9 [229]
3 [1.4]
9-BDE3 D 1" [25.4] 1" [25.41
- -
900
[62.1]
25/e
[671
15/8
[411
85/8 [2191
71/2
[191]
91/a [232]-
3 [1.4]
9'BED E 3/4" [19.01 11/4" [31.81
300 [20,71
900
[62.11
25/s
[67]
2
[51]
83/4 [222]
75/8
[194]
93/8 [2381
4 [1.81
9`BEF3 E 11/4" (31.8) 11/4" [31.8]
- -
91)0
,:[62.1]
3
[76]
2
[511
91/8 [232]
8
[2031
93/4 [2481
4 [1.81
9'BFE F 1" [25.4] 11/2" [38.11
300 [20.71
600
[41.4]
27/8
1731
23/8
[601
91/8 [2511
83/4
[222]
10112 [2671
6 [2.7]
9"BFG3 F 11/2" [38.11 11/2" [38.11
-
600
[41.41
3
1761
23/8
[601
10 (2541
87/8
12251
10518 [2701
6 [2.71
9'BGF G 11/4" [31.8] 2" [50.81
300 120.71
600
[41.41
31/4
[89]
25/8
[67]
111/4 [286]
101/8
[2571
113/4 [298]
8 [3.6]
9-BGH3 G 2" [50.8] 2" [50.81
- -
600
[41.41
31/4
[89)
25/8
[671
11114 [2861
101/8
[2571
113/4 [298]
8 [3.6]
9'BHG H 11/2" [38.11 21/2" [63.51
300 [20.7]
500
[34.51
31/2
[89]
23/4
[701
13 [330]
111/e
1283]
121/2 [318]
11 [5.01
9"BJH J6 2" [50.8] 3" [76.21
300 [20.71
500
[34.51
4
11021
31/4
(891
141/2 [3681
121/2
[318)
151/8 (384]
15 [6.81
1. Maximum temperature controlled by resilient seat/seal
material.
Plain
Th aded C
P cked c
2. Replace asterisk with desired Model Number. Data
Lever
Ca'
ver
applicable to all models.
3. Available with SS trim only.
4. Maximum pressure on steam is 250°F.
�
5. Maximum pressure on steam is 300'F.
A
A
t«s
s
A
6. For C dimensions: pressures above 200 psig [14 barg]
add 1.25-inch (31.8 mm] to the overall height.
B
B
B
10
Models 912, 913, 918, 919 ASME Section Vlll, Steam/Air/Gas/
Liquid, `UV' National Board Certified. Also available for Vacuum Service
No. Part Name Materials
1
Nozzle'
Brass, B21 Alloy 485, (SS, A351-CF8M1 Models 913, 919 only)
r,Inp Body .'.
Teflon
3
Body
Bronze, B584 Alloy 84400
4
Warn Ring,::
:',SS A743-GF8M
5
DisC2
SS, A479-316
6
3et'Serew,Nut `
Brass,616,
7
Set Screw
Brass, B16
8
= opal.•: ..'
Teflon z ;,
9
Retainer Ring
SS, A313-316
folder
Qrass; B16, {SS A3.51 GF8M Models 913 919 oglyj
11
Guide3
Brass, B16
12 `
Bonnet 0 nng '.
Teflon 3.. - "
13
Screw
SS, Commercial 18-8
14 '
' Colled.Spring Pin
$S, A313-302
Steel A231/A231M, Cadmium Plated
15
Spring
SS: A313-302
SS: A313-316
Alloy steel: A681-1112
16
Bonnet4
Brass, 64JI
V , ., ��'�
17
Spring Step
Brass, B16
18
Stem
Brass, B16
19
Wire and Seal
SS wire and Lead seal, Commercial
20
Cap
Brass, Bib
21
Compression Screw
Brass, B16
22•
,tatn;Nut °l: F.OA
s, B1fi '.
23
Cap 0-ring
BUNA-N
24
Body'Plugs
Brass,.816
Guide
Brass, B16
25
Guide Locknut
Brass, B16
Shield
SS, A167-316
Disc Holder
Brass, B16 (Model 912 only)
26
Spindle
Brass, B16 (Model 912 only)
1.
F through J orifice nozzle material is 3. G through J orifice guide material is
Bronze, B62.
Bronze, B584, Alloy 84400.
2.
Material Letter Designation 4. F through J orifice bonnet material is
Vlton®-A A
Bronze, B584, Alloy 84400.
BUNA-N B
5. Body plug and tapped hole not available for
Silicone S
liquid service.
Models 912, 913, 918, 919 ASME Section Vill, Steam/Air/Gas/
Liquid, `UV' National Board Certified. Also available for Vacuum Service
Parts and Materials,7'.Model 912 Packed Lever
No. Part Name Materials
18 Cap 0-ring
BUNA-N 70 Duro, Commercial
19 Jam Nut
Brass, B16
20 Lift Cam
SS, A743 CF8M
21 Cotter Pin
Steel, Commercial
22 Lever
Zinc Plated Steel, A108
23 Drive Screw
SS, Commercial
24 Retainer Nut
Brass, B16
25 Retainer 0-'ring
BUNA-N 70 Duro, Commercial
26 Litt Cam 0-ring
BUNA-N 70 Duro, Commercial
27 Cap
Bronze, B584 Alloy 84400
28 Lift Nut
SS, A479 316
29 Lift Washer
SS, A479 316
30 Stem
Brass, B16
31 Compression Screw
Brass, B16
32 Coiled Spring Pin
SS, A313 302
33 Body PIug4
Brass, B16
Guide
Brass, B16
34 Guide Locknut
Brass, B16
Shield
SS, Al67 316
No.
ModelParts and Materials -
Part Name
Materials
Cadmium plated steel: A231/A231M
SS:A313-302
11
Spring
SS: A313-316
Alloy steel: A681-H12
12
Bonnet3
Brass, BIB a
.:
13
Jam Nut
Brass, B16
14
Compression Screw
Brass, B16
15
Lever
Steel Cadmium Plated, A109
16
Cap
Brass, 8179
17
Lift Nut
SS, A479-316
18
Lift Washer
SS, A479-316
19
Rivet
Steel, Commercial
20
Screw
SS, Commercial GR. 18-8
21
Spring Step
Brass, B16
22
Disc Holder
Brass, Bibs, .
Spindle
Brass, B16
23
22
21
20
19
18
15
14
13
12
ill
9d 9R 9R
27
28
29
30
31
16
17
18
19
20
21
Models 912, 913, 918, 919 ASME Section Vill, Steam/Air/Gas/
Liquid, `UV' National Board Certified. Also available for Vacuum Service
M. W.
Model
Number 0 1 1 1 2 1 3 1 4 1 5 1 6 1 7 1 8 1 9 10 1 11 1 12 1 13 1 14 1 15
Position
Example 9 1 1 2 1 B I J I H I M 1 0 1 1 1 - I K I C 1 0 1 3 FO 0
Model
912
913
918
919
Connection Model
B - Male x Female Threaded or NPT
Orifice
D G
E H
F J
Inlet Size
C - 1/2-inch [15 mm]
D - 3/4-inch [18 mm)
E - 1-inch [25 mm]
F - 11/4-inch [32 mm]
G - 1112-inch [40 mm]
H - 2-inch [50 mm]
Seat/Seal Material
M
Metal -to -metal
B
BUNA-N 200°F [9YC]
E -
EPR 350°F [177°C]
S -
Silicone 406°F [208°C]
V -
Vitone 406°F [208°C]
N -
Neoprene 3007 [149°C]
Variation (01 through 99)
Number provided only by manufacturer to cover specific
feature or option.
01 - Threaded cap
02 - Threaded cap with gag
03 - Plain lever
04 - Plain lever with gag
05 - Plain lever with vibration dampener
06 - Packed lever
07 - Packed lever with gag
Design Revision
Indicates non -interchangeable revision. Dash (-) if original design.
Valve Service
J - Liquid ASME Section VIII (Standard Cap/Packed Lever only)
K - Air/Gas ASME Section VIII (Plain Lever/Packed Lever required for air)
L - Steam ASME Section VIII (Plain Lever/Packed Lever required)
M - Liquid (Standard Cap/Packed Lever only)
Q - Vacuum (Standard Cap/Packed Lever only)
Spring Material
E - SS
Set Pressure
3 psig [0.2 barg] (0003) through 900 psig [62 barg] (0900)
Vacuum 6-inch HG [200 mbarg] (0006) through 29-inch HG [1000 mbarg] (0029)
Models 910, 911, 912, 913, 916, 917, 918, 919
Set Inches
Orifice
Area, in2
Mercury
O
E
F
G
H
J
(0.1213)
(0.2157)
(0.3369)
(0.553)
(0.864)
(1.415)
6
24
43
68
111
173
284
7
26
45
71
117
182
298
8
27
47
74
121
189
310
9
27
49
76
125
195
320
10
28
50
78
128
199
327
11
28
51
79
129
202
331
12
29
51
80
131
204
334
13
29
51
80
131
204
335
14
29
51
80
131
204
335
15
29
51
80
131
204
335
16
29
51
80
131
204
335
17
29
51
80
131
204
335
18
29
51
80
131
204
335
19
29
51
80
131
204
335
20
29
51
80
131
204
335
21
29
51
80
131
204
335
22
29
51
80
131
204
335
23
29
51
80
131
204
335
24
29
51
80
131
204
335
25
29
51
80
131
204
335
26
29
51
80
131
204
335
27
29
51
80
131
204
335
28
29
51
80
131
204
335
29- _.,
29
51
80
131
204
335
010.31
[0261.94mm]
0 YN� /// / \\\\ \�i ` 't 1
i
d II I I " I tl" II fl
I II � II II I 1 II IR
I II I I II I I II fl tl.
1 N + i II I I Y II Y
II R II II Y Y tt Itl I
7.22 1 Y I Y II 1 tl u Y Y I
[183.41mm]
I fl I II I fl tt 1 I 1
--w- --r-�r - - -�-- - --�-7
2.25
[57.15mm]
ITIMuyr
REVISIONS
Dilution air inlet Filter
REPLACEMENT ELEMENT# 31P
MATERIAL
I'0 yestcE
CFM FLOW
SURFACE AREA
I. D.
O.D.
HEIGHT
u
C
11 B
MODEL# HOUSING MATERIAL FINISH
Tn, m+wmaan <mL<Inoa n.r"m m <o"na.mlol ene m°
SaMrp uona«Lun,p Inc. e a 1m4—
SOLBERG MANUFACTURING INC.
proprty or ma
yev .;m m. ..R.«ea Nne.ncene ba a �n ,wi a
1151 W. ARDMORE AVE.
..ree,,..e. °°Pie '" °"y' "'�""'•'°°
VenMenee to e—A anEnaly er 'n Derr. nor u.ee t<.
onr wn,".e am uwn ro• .Ala rc — raeNere. a .1.
e
ITASCA, IL 60143
630/773-1363
na retumnd uDm rwasl b S< " MorMea Nv Inch
TM one.. mrraan ;. oeenx>n'h oea a« o"r
DescRlanON:
+er enn, mr ane..minalom .Nc mw Dopy .o ure
11
aw�nwoe <oaeb.a n...". Tn" m . u.<Nx teen. toe.
c
,
®
SCALE:
-
SHEET Wt. MAX_
/�
A
UNLESS OTHERWISE SRECIFlED FRACTIONS. S1/A
DECMALS:.XX }.126
DIMENSIONS ARE IN INCHES ,]
TOLERANCES ARE:
AN",S },083 3z
SALES REP:
ARRPM I_S DATE
I—N
ENCINCfl
SIZE : C
MATERIAL. FINISH:
DRAWING NUMBER.
CUSTOMER APPROVAL:
DATE:
2
1
PRM Level Controls PR
'e�NRW.MA
PRODUCT RECOVERY MANAGEMENT
Float Stem Assemblies: PRM manufactures
standard 1 Float, 3 Float, and 4 Float stem
assemblies for level control use in
environmental systems. PRM float stems are
kept in stock for immediate delivery.
• Stem and Floats are 316 Stainless Steel
• Delrin® Retention Rings
• Industrially Hardened, Rated for Millions
of Cycles
• Stem is 1/2"OD and Connection is 1/4"NPT
• All Assemblies come with 25' Petroleum
Resistant PVC Shielded Probe Cable.
• RoHS Compliant
Site Tube Assembly: PRM standard site tube
assemblies are manufactured from virgin
clear and Schedule 80 PVC and all joints are
fused with heavy body solvent glue.
• Schedule 80 Unions with VitonTM 0-rings
• Integral Flow Equalizer
• Cam Lock Assembly has Quick Removal
for Cleaning and Maintenance
• Can Retrofit to Existing Equipment
• Can Supply as a Field
Assembly Kit
Intrinsically Safe
Barrier Relays:
PRM uses Intrinsically
Safe Barrier Relays in
conjunction with 3 float it
stems and other switches
located in hazardous
locations. Barrier Relays offer low voltage
protection and Intrinsic Safety. These floats
and devices are useable in Division 1,
Division 2 and Standard Locations.
Absolute Quality is our Goal... Genuine Service is our Habit!
PRM can custom build a float assembly for your
requirements —contact sales@prm-net.com
with your specifications for a quick quotation.
Custom assemblies can ship within
24 hours of approval.
Product Recovery Management, Incorporated
(888) TREAT -IT
888-873-2848 • 919-957-8890 • www.prm-net.com • sales(EDprm-net.com
Butner, NC • Webster, NY Lakeland, FL
* Actual equipment specifications may vary. Please contact Product Recovery Management, Inc. for additional details. P-07
CONTINENTAL'
ULT-nAPU MF)
Pump Guide
How Progressing Cavity Pumps work:
Progressive Cavity Pumps have similar characteristics to rotary or reciprocating pumps, such as piston,
diaphragm, lobe, and screw pumps. They are also known as an eccentric screw pump due to the motion
of the rotor. The one common feature being the sealed cavities with operational similarities like being
able to pump at extremely low rates, to even high pressures. The similarity between other pumps and
progressive cavity pumps generally ends there. Of all the types of pumps available, progressive cavity
pumps are able to handle a wider range of fluid viscosities and properties than any other type of pump.
The unique design of the pump makes them useful for a variety of pumping applications, such as
transferring and metering while handling shear sensitive, abrasive and viscous fluids.
The rotors are made of hardened alloy steel or stainless steel and are covered with a chrome plating to
give resistance to corrosive and abrasive materials. Some types of liquids affect the chrome plating and in
those applications a non -plated rotor should be used.
Stators are metal tubes with internally molded cavities of synthetic or natural rubber
The rotor seals tightly against the flexible rubber inside the stator as it rotates, forming tightly sealed
cavities which carry the liquid toward the discharge port. The liquid does not change in shape or size
when pumped due to the tightly sealed cavities. The effect of the progressive cavity design is that the
fluid is moved at a very predictable and steady rate. Positive displacement of the pump starts the instant
the rotor turns. The liquid acts as the lubricant between the pumping elements and should not run dry.
HOW THEY WORK
J_1 Rotor turns within the flexible rubber
stator
i Tightly sealed cavities are formed
0.4 Forces materials to the discharge port
Pumping action begins when the rotor
tums. Liquid acts as a lubricant.
Continental Pump Company
29425 State Hwy B I Warrenton, Missouri 633831 Tel: 636-456-60061 Fax: 636-456-43371 Email: sales@con-pump.com
www.continentalultrapumps.com
[CON TiNENTAL
The reason progressive cavity pumps are used are because they are durable with only one moving part,
rated for longevity. In operation our pumps are primarily a fixed flow rate pump and offers long life and
reliable service transporting thick, viscous fluids. Abrasive fluids can shorten the life of the stator, but by
slowing down the RPM's will help reduce the wear. Slurries can also be pumped reliably if the slurry is
viscous enough to maintain a lubrication layer around the particles and protect the stator.
At the points where the rotor touches the stator, the surfaces are generally traveling diagonally, so these
areas need to be lubricated by the fluid being pumped. This means that more torque is required for
starting. Rapid deterioration of the stator can happen as a result of the pump operating without fluid,
this is called "Run Dry".
The 7 key advantages Progressing Cavity Pumps:
Positive Displacement
This occurs at the turning of the rotor which develops a positive pumping action similar to a piston
moving through a cylinder. The pump pressure developed does not depend upon the speed of the
rotating rotor. The capacity of the pump, the approximate viscosity, and pressure can be projected for
particular operating conditions.
Uniform Discharge Flow
Fluids are uniformly discharged without pulsation in a constant steady flow. Displacement remains the
same with each revolution of the rotor permitting accurate and predictable metering relative to the fluid
being pumped. Because of the unique flow characteristics, these pumps are well suited for low -shear
applications.
Internal Velocity of Fluids
When the pump is in process, all fluids are pumped with a minimum amount of turbulence, agitation,
pulsation or separation disturbance.
Self -Priming
Pumping action starts at the time the Rotor is turned and it is capable of 28 feet of suction lift based on
water in an appropriate installation. The liquid being pumped acts as a lubricant between the rotor and
stator, and forms a continuous seal to create good suction and discharge capabilities. Do Not Run Dry.
Continental Pump Company
29425 State Hwy B I Warrenton, Missouri 633831 Tel: 636-456-60061 Fax: 636-456-43371 Email: sales@con-pump.com
www.continentalultrapumps.com
CONT1NENTAW
ULTPl1PUMP
Solids in Suspension
Solid particles over a wide range of size and shapes, as large as 1 1/8 inches in diameter, are pumped with
no difficulty.
Reversible
Our pumps can be operated clockwise or counter -clockwise with effective performance in most
installations. Contact us to see if your application is suitable for reverse operation.
Installation
Our pumps can be purchased separately or built into complete units. These units can be mounted on
welded steel bases with specified couplings or belt guards and can either be driven by flexible couplings, v
belts, gearbox reducers, or hydraulic motor adapters. If variable speed drives are needed the units can be
driven by either electric motors, gasoline engines, diesel engines or air motors. Our pumps can also be
mounted horizontally or vertically and the Suction Port can be rotated up to 270 ° position for
appropriate entry of the liquid.
Pump Selection Guide
Understanding the pump terminology helps to properly select the best performing Continental
Progressive Cavity Pump to fit your pumping needs. Here are a few things you should know:
The Capacity or Volume is the rate of flow in gallons per minute or GPM.
Pressure is determined by how much is required to move the liquid that is being pumped through the
piping system and the kind of liquid being handled. The difference between the pressure required at the
pump discharge and the pressure being introduced into the pump suction is the differential pressure and
is expressed as pounds per square inch or PSI
Viscosi is the resistance to flow as expressed by various scales of measurement; however, the most
commonly used is centipoise. The viscosity usually changes with temperature and should always be
considered.
For conversion purposes the formulas below are of value:
Centipoises = centistokes x specific gravity
Centipoises = S5U x specific gravity
SSU= saybolt seconds universal
Continental Pump Company
29425 State Hwy B I Warrenton, Missouri 633831 Tel: 636-456-60061 Fax: 636-456-43371 Email: sales@con-pump.com
www.continentalultrapumps.com
II .
'PROGRESSING CAVITY
Temperature refers to the maximum and minimum temperatures at which the fluid is to be pumped. This
is a highly important factor in pump selection. High temperatures can cause distortion and swelling of
the stator materials and low temperatures can affect viscosity that reflects in flow characteristics and
horsepower requirements.
Operating Time or Operating Cycle of the pump should also be considered; whether the pump is to run
continuously or intermittently can be a factor in the selection of the drive.
Corrosion depends on whether the fluid being pumped is neutral, acid or alkaline. All should be
considered when selecting the proper materials of pump construction. The pH value of the fluid should
be known or determined. A pH of 7 is neutral, below 7 is acid and above 7 is alkaline.
Abrasion depends on the abrasive properties of the fluid to be pumped and how they are classified.
Abrasives can look alike and appear to have similar properties; however, they can produce different
wearing characteristics. You must classify the fluid in order to select the proper pump construction and
operating speed. These 4 classifications will serve as a guide and help in the determination of the
necessary materials needed in the pump construction:
No Abrasives
Example: Clear Water, Gasoline, Fuel Oil, Lubricating Oil.
Light Abrasives
Example: Dirty Water containing Silt and/or small amounts of Sand or Earth.
Medium Abrasives
Example: Clay Slurries, Potters Glazes, Porcelain Enamel, Frit, Sludge, Wood Dust in Water.
Heavy Abrasives
Example: Slurries containing large amounts of Sand, Emery Dust, Lapping Compounds, Mill Scale,
Plaster, Grout, Roof Gypsum.
Continental Pump Company
29425 State Hwy B I Warrenton, Missouri 633831 Tel: 636-456-60061 Fax: 636-456-43371 Email: sales@con-pump.com
www.continentalultrapumps.com
C�NTiNEPgTAL
ULTAF'UMP
Pump failure is a possibility if inaccurate pump application information is given.
The pump application data sheet is a convenient tool used to relay the required information to the
application specialists to help them assist in making the proper pump selection.
There are 6 key components that should be known about your pumping application. They are: flow rate,
pressure, pH, viscosity, temperature, and the material being pumped. All components are necessary for
proper sizing of pump for your specific application requirements.
Continental Progressive Cavity Pump Models
Rigid Stator Pumps
CL Model- Suitable for a wide variety of applications and are the most frequently used. When properly
applied they give excellent long life performance at the most economical cost. This model's suction
housing can be rotated from 90' to 270' upon request.
CM Model- Similar to the CL Model, except has a larger drive head to handle the increase horsepower
that is needed to produce the higher pressures that can be developed by these pumps. This model's
suction housing can be rotated from 90° to 270° upon request.
Rigid Stator Pump with Crown Gear Joint Connections
CG Model- Designed to handle the heavier applications of sewage, industrial waste, polluted liquids and
slurries. Incorporated into this more rugged pump is a drive train using crown gear joint connections to
the rotor and drive shaft. This model's suction housing can be rotated from 90° to 270° upon request.
Wobble Stator Pumps
CP Model- The CP Model, also known as a bare shaft pump, operates with low costs and are compact
making them ideal for light duty use. This model is available with horizontal or vertical suction.
CPM Model- Similar to the CP Model, except it is a closed coupled type pump that is driven by a
Continental spec. motor that is directly bolted to the pump. This model is available with horizontal or
vertical suction.
CPML Model- Similar to the CPM Model, except it is driven by a standard motor attached by specific
motor coupling for different drive arrangements. This model is available with horizontal or vertical
suction.
Continental Pump Company
29425 State Hwy B I Warrenton, Missouri 633831 Tel: 636-456-60061 Fax: 636-456-43371 Email: sales@con-pump.com
www.continentalultrapumps.com
PROGRESSING CgVITr'—
U I
CP Model Number Nomenclature:
Materials used in the pumps are based on the fluid to be handled and are indicated in the model number
nomenclature.
CPML56 - CSQMN
1 2 3 4 5 6 7 8
(1): Indicates the pump model designation (CP, CPM, CPML Model)
(2): Indicates the pump frame size designation
(3): Indicates the pump body casting material
(4): Indicates the rotor material
(5): Indicates the stator material
(6): Indicates seal type: mechanical seal or packed seal (For mechanical use M, for packed use D)
(7): Indicates if the drive shaft, flex joint, and rotor is pinned or threaded. (For pinned use P, for
threaded use T)
(8): Indicates if the pump has vertical suction housing. If horizontal is preferred no designation will be
used.
Material of Construction
Continental Part Description
Continental Letter
Designation
Part Materials
Pump Body
C
Cast Iron
S
316 Stainless Steel (CF8M)
Rotor
D
Chrome Plated Alloy Steel
S
Chrome Plated Stainless Steel
Stator
Q
Buna Nitrile
B
EPDM
F
Vitonm
Seal Type
M
Mechanical Seal
D
Packed Seal
Continental Pump Company
29425 State Hwy B I Warrenton, Missouri 633831 Tel: 636-456-60061 Fax: 636-456-43371 Email: sales@con-pump.com
www.continentalultrapumps.com
C�NTINENTA�®
�LTRAPUMi'
PERFORMANCE DATA
MODEL CP-44
NPSH REQUIRED 4.1
HP I GPM
0.8 16.0
0.7 14.0
0.6 12.0
0.5 10.0
0.4 8.0
0.3 6.0
0.2 4.0
0.1 2.0
TEST LIQUID . WATER AT 70"F
0 10 20 30 40 50
DIFFERENTIAL PRESSURE (P.S.I)
Continental Pump Company
29425 State Hwy B I Warrenton. Missouri 633831 Tel. 636456-6006 i Fax: 636-456-43371 Email: sales@con-pump.com
www.continentalultrapumps.com
PROGRESSING CAVITY
Performance Data
CP Model
PERFORMANCE DATA
CAPACITY- Gallons per Minute (Water at 70°F)
MOTOR
PUMP SPEED
PUMP
DIFFERENTIAL
PRESSURE
HORSE
POWER
1750
1150
870
180
430
RPM
RPM
RPM
RPM
RPM
0 1
1.9
1.3
1.0
0.7
0.5
So
1.5
0.9
0.2
CP-15
1/2
100
1.0
0.7
150
0.6
0.4
25
4.1
2.7
2.0
1.3
0.9
CP-22
1/2
75
2.6
1.7
1.3
0.8
0.6
0
9.4
6.0
4.6
3.1
2.3
CP-33
1/2
50
4.2
2.7
2.0
1.3
0.9
CP-44
25
0
12.0
24.0
7.8
15.6
5.9
11.7
4.0
7.9
3.0
5.8
3/4
CP-56
1 1/2
35
20.5
13.3
10.0
6.7
4.9
0
53.0
34.5
26.0
17.5
13.0
CP-67
20
43.0
28.0
21.0
14.0
10.3
2
50
25.0
16.3
12.3
8.3
6.1
Continental Pump Company
29425 State Hwy B I Warrenton, Missouri 633831 Tel: 636-456-6006 1 Fax: 636-456-4337 1 Email: sales@con-pump.com
www.continentalultrapumps.com
1
PROGRESSING CAVITY
2800
1750
1150 870 580 430
180
100
RPM
RPM
RPM RPM RPM RPM
RPM
RPM
VISCOSITY (Centipoise)
3
100 500 1000 3000
5000
10,000
1
to
to to to to
to
to
100
500 1000 3000 5000
10,000
20,000
30
Canned
Table
Peanut
Water
Weight
Honey
Molasses
Paste
Milk
Syrup
Butter
Oil
None
None
None
Light
Medium
I Medium
Heavy
Heavy
Lapping
Dirty
Clay Slurries
Compounds
Clear Water Gasoline
Water
Porcelain Enamel
Mill Scale in
Water
Continental Pump Company
29425 State Hwy B I Warrenton, Missouri 633831 Tel: 636-456-6006 1 Fax: 636-456-43371 Email: sales@con-pump.com
www.continentalultrapumps.com
CONTINENTAL
.,
ULTRAPUMP
Dimensions & Weights
CP Model
WEIGHT
PORT SIZES
PUMPS
DIMENSIONS (INCHES)
(CBS)
INLET
OUTLET
SUCTION
DISCHARGE
A
B
C
D
E
F
6
H
U
CP15 •
_._.,
CP22
12- 7/16"
6-13/16"
5- 5/8"
3- 1/2"
5- 3/4"
5- 1/2"
3- 1/4"
3- 11/16"
3- 3/8"
1- 7/16"
5/8'.
15
3/4"
3/4"
CP33
CP44
CP56
16 11/16"
9- 3/4"
6- 15/16"
4- 9/32"
7- 9/32"
7- 1/2"
6"
4- 3/4"
1- 9/16"
2- 3/8"
3/4"
40
1-1/2"
CP67
19- 9/16"
11- 15/16"
7- 5/8"
4- 1/2"
8- 1/4"
8- 1/4"'
6"
4- 7/8"
4- 9/16"
2- 1/8"
1"
85
2" 1
2"
PACKED
CP15
CP22
14- 3/4"
6- 1/4"
8- 10"
3- 1/2"
5- 7/8"
3 1/4"
3"
6- 7/16"
1- 7/16"
S/8"
18
3/4'
1��„
CP33
CP44
PACKED
18- 13/16"
9- 3/4"
9- 1/16"
4- 9/32"
7- 9/32"
7- 1/2"
6"
4- 3/4"
5- 11/16"
2- 3/8"
3/4"
44
1-1/2"
1-1/4"
CP56
PACKED
,
`
12"
10"
4- 1/2"
8- 1/4"
8- 1/4"
E"
4 3/4"
7 1/8"
/8"
1"
90
-
CP67
CPM15
CPM22
18- 3/4"
12"
6- 13/16"
3- 1/2"
5- 7/8"
5-,
6- 1/2"
4"
10- 3/4"
7"
48
3/4"
3/4"
CPM33
3/4
CPM44
CPM56
22- 15/16"
13- 3/16"
9- 3/4"
4- 1/2"
7- 1/2"
7- 1/2"
9"
10"
12- 15/16"
8- 1/4"
80
1-1/2"
1-1/4"
CPM67
25- 1/4"
13- 5/16"
12"
4- 1/2"
7- 3/4"
8- 1/4"
9"
10"
15- 5/16"
8- 5/8"
117
2"
2"
CPML15
CPML22
20- 3/8"
13- 9/16"
6- 13/16"
3- 1/2"
5- 3/4"
6- 1/2'
6- 1/2"
4"
13- 1/8"
6-3/4'
52
CPML33
CPML44
CPML56
25- 3/8"
13 3/4"
9- 3/4"
4- 1/2"
7- 1/2"
7- 1/2"
9"
10"
13- 1/12"
i 8- 1/4"
85
1-1/2"
1-1/4"
CPML67
27- 7/8"
15- 7/8"
12"
4- 1/2"
7- 3/4"
8- 3/8"
1 9"
10"
1 17- 7/8"
1 8- 11/16"
1
1 125
2'
7"
Dimensions are for reference only.
Do not use above dimensions for limited space installations, request certified drawing.
0 = diameter
All CP pumps are offered with vertical housing option. See vertical housing dimensions.
Continental Pump Company
29425 State Hwy B I Warrenton, Missouri 63383 ( Tel: 636-456-6006 1 Fax: 636-456-4337 1 Email:sales@con-pump.com
www.continentalultrapumps.com
, long
PROGRESSING CAVITY
-a IWO
ELE , '' -
CPM Model
CPM15 C PAA22 CPM33 CPMU
CPM56
Der tAC
Continental Pump Company
29425 State Hwy B I Warrenton, Missouri 63383 1 Tel: 636-456-6006 1 Fax: 636-456-43371 Email:sales@con-pump.com
www.continentalultrapumps.com
EeDEKKER
VACUUM TECHNOLOGIES, INC.
Why more and more customers are
switching to the system:
lr The only system on the market with a full 3-
year warranty!
-vr Patented, high -efficiency DX-5
separator eliminates oil carry-over
concerns.
Y Sturdy bearing pedestal mounts to
standard NEMA C-face motor.
1/ Rugged, high -quality, industrial system,
offering years of trouble free operation.
-Tr Extended -life seal -fluid is not used as a
lubricant. Change interval is not critical,
resulting in a minimum of 10,000 hours of
continuous operation.
l*' Direct drive at low speed (1750RPM)
eliminates the use of V-belts, resulting in
very low maintenance and zero downtime.
--vr Extremely low operating noise level
makes this system desirable in today's
workplace.
�/ Continuous operation over the full
vacuum range without overheating.
ll Carry-over of soft solids and/or minimal
amounts of liquid does not cause damage
to the internal parts of the pump.
-Y' Air-cooled design is standard with water-
cooling available at no extra charge.
-vr Improved compact design.
--Vr Now available with optional Variable
Frequency Drive, resulting in lower power
consumption.
Performance Characteristics
Nominal capacity:
300CFM
Motor: 50Hz/11 kW/15HP - 60Hz/15kW/20HP
Speed:
1450/175ORPM
Maximum vacuum:
29"Hg/982mbar
Weight (approximate):
593Kg/1305Lbs
Maximum gas inlet temperature:
212°F/100°C
Maximum noise level (at 3 feet):
76dBA
Oil capacity (approximate):
45Ltr/12 GAL
Performance based on atmospheric pressure
equal to 29.92"H - 1013mbarA
11. VMAX SYSTEMS
114*i4 - oil -sealed
vacuum pump system
VMX0303K
a
! DEKKER
JR&ps.
rl-
>c
VMX0303K Tolerance 10 %
Vacuum (Inch. Hg.)
29.5 29.2 29 28.5 28 27.5 27 26 25 24 23 22 20 18 14 10 5 2
OEM mom
Q30
2s
��20
a MEEM
Q 15
Q 10 ME
c
0 5
U
7
10 20 25 30 40 50 60 70 80 90 100 200 300 400 500 600 700
Absolute pressure (Torr)
Information contained in this document is for reference only. 5ubject to change without notice.
935 SOUTH WOODLAND AVENUE, MICHIGAN CITY, IN 46360-5672 Please visit our Website at Page number Reference
TOLL-FREE:888-925-5444 TEL.:219-861-0661 FAX:219-861-0662 www.dekkervacuum.com 11-222-NEW 0508/7/JD/ado
PRM Oil Water Separators
4 A & ILI
PRODUCT RECOVERY MANAGEMENT
Absolute Quality:
PRM Oil Water Separators provide high
efficient fluid separation with low
maintenance that can operate as a
standalone system or used with
integrated packages.
The PRM Difference: These industrial -
duty units are designed for flow rates
from 1 to 100 GPM. PRM separators are
manufactured using heavy gauge 304
stainless steel and can be supplied with
internal sumps or just the body only. Our
field adjustable skimmers provide
efficient separation for varying site
conditions.
For applications with heavy solids
loading we can incorporate slant rib
clarification plates for precipitating
solids into an integrated collection tank.
Flows up to 100 GPM
Typical Features Include:
• Table -Mounted, Painted Steel
Welded Frame
• Stainless Steel Welded Construction
• PVC Coalescing Media Pack
• Stainless Steel Media Anchor Hardware
• Adjustable PVC Oil Skimmer with
Viton O-Rings
• Removable Lid with SS Tee Bolts
• Vent Port, Sump Drain, Cleanout Port,
and Oil Outlet Port
• Sludge and Grit Chamber with
Manual Drain
Absolute Quality is our Goal... Genuine Service is our Habit!
' Options and Services I
• Optional Aluminum Construction
• Equalization Tanks for Increased Retention Times
• Reverse Configurations for DNAPL Separation
• Stainless Steel Coalescing Media
• UL 508A and 698A (US and Canada) Control Panels
for Pump Up, Pump Down, and High Level Alarm
• Custom Integration Into New or Existing Systems
• Field Installation, Startup and Operations Services
Contact PRM for Custom Requirements
We Can Manufacture It!
www.prm-net.com
Product Recovery Management, Incorporated
(888) TREAT -IT
888-873-2848 • 919-957-8890 • www.prm-net.com • salesO-prm-net.com
Butner, NC - Webster, NY • Lakeland, FL
* Actual equipment specifications may vary. Please contact Product Recovery Management, Inc. for additional details. E-02
PRM OWS-20
Absolute Quality:
PRM Oil Water Separators have been
designed with groundwater remediation
in mind, where petroleum products such
as gasoline, diesel fuel, jet fuel or other
petroleum products are pumped from
the subsurface. The oil water separator
units are designed to remove and skim
all free phase product from the water
stream down to 20 micron. The product
free water is stored in an integrated
sump located under the oil water
separator.
NOMINAL FLOW RATES:
OWS-20: 5-20 Gallons Per Minute
OWS-20 Features:
• 24"W x 60"L x 24"H 14 Gauge Stainless
Steel Construction
• 20"W x 60"L x 30"H sump under the
separator
• 2" Inlet/ Outlet
• 2" Adjustable Oil Skimmer, Outlet on
Both Sides
• Two 1" Air Vents
• 2" Wide Gasket Lid with Easy Turn
Retainers
s
PRODUCT RECOVERY MANAGEMENT
Absolute Quality is our Goal... Genuine Service is our Habit!
** Options and Services **
• Polypropylene Clarifier Plates
• Alternate coalescing media CPVC or other
• Equalization Tank
• Transfer Tank
• Product Storage Tanks with H/L Switches
• Bag Filtration
• Sight Tube Assembly
• Level Controls
Please talk to a PRM representative to
ensure that the separator you need is Contact PRM for Custom Requirements.
properly sized and specific for your We Can Manufacture It!
application. www.prm-net.com
Product Recovery Management, Incorporated
(888) TREAT -IT
888-873-2848 • 919-957-8890 - www.prm-net.com - salesO-prm-net.com
Butner, NC - Webster, NY - Lakeland, IF
* Actual equipment specifications may vary. Please contact Product Recovery Management, Inc. for additional details. E-02
2
PRM Level Controls e
'ew�NRW.M
PRODUCT RECOVERY MANAGEMENT
Float Stem Assemblies: PRM manufactures
standard 1 Float, 3 Float, and 4 Float stem
assemblies for level control use in
environmental systems. PRM float stems are
kept in stock for immediate delivery.
• Stem and Floats are 316 Stainless Steel
• Delrin® Retention Rings
• Industrially Hardened, Rated for Millions
of Cycles
• Stem is 1/2"OD and Connection is 1/4"NPT
• All Assemblies come with 25' Petroleum
Resistant PVC Shielded Probe Cable.
• RoHS Compliant
Site Tube Assembly: PRM standard site tube
assemblies are manufactured from virgin
clear and Schedule 80 PVC and all joints are
fused with heavy body solvent glue.
• Schedule 80 Unions with VitonTM 0-rings
• Integral Flow Equalizer
• Cam Lock Assembly has Quick Removal
for Cleaning and Maintenance
• Can Retrofit to Existing Equipment
• Can Supply as a Field
Assembly Kit
Intrinsically Safe
Barrier Relays:
PRM uses Intrinsically
Safe Barrier Relays in
conjunction with 3 float 10
stems and other switches
Absolute Quality is our Goal... Genuine Service is our Habit!
D
0
located in hazardous PRM can custom build a float assembly for your
locations. Barrier Relays offer low voltage requirements —contact sales@prm-net.com
protection and Intrinsic Safety. These floats with your specifications for a quick quotation.
and devices are useable in Division 1, Custom assemblies can ship within
Division 2 and Standard Locations. 24 hours of approval.
Product Recovery Management, Incorporated
(888) TREAT -IT
888-873-2848 • 919-957-8890 • www.prm-net.com • sales(a-prm-net.com
Butner, NC • Webster, NY • Lakeland, FL
* Actual equipment specifications may vary. Please contact Product Recovery Management, Inc. for additional details. P-07
High Head Pump
High Volume Pump
AMT Stainless Steel Solids Handling End Suction
Centrifugal pumps are designed for continuous duty
high flow and high pressure applications including:
chemical processing, liquid transfer, cooling,
pressure boosting, circulating, dirty water and
applications requiring contaminant free pumping.
Constructed of rugged deep drawn stainless steel
for durability and corrosion resistance. Investment
cast stainless steel closed impeller for enhanced
performance, high efficiencies and handles a
maximum of 1/8" diameter solids.
All models include Viton' Type 21 mechanical seals
and 0-rings which offer a broad range of chemical
compatibility. Cast iron motor adapter provides
a positive and rigid mounting to motor. Pumps
include Totally Enclosed Fan Cooled (fEFC)
motors or Open Drip Proof (ODP) motors by special
quote. Pumps are not self -priming and require
flooded suction.
St��njes�s Sze��►
Straight Centritkya/
PAF#MrC
• Stainless Steel Construction with
Viton' Mechanical Seal and O-Ring
Investment Cast Stainless Steel
Impeller
High Head and High Volume Models
Maximum Temperature 200° F
Maximum Flow 756 GPM
Maximum Head 730 Ft,
Chemical Resistant Design
Discharge Port Rotates in 90°
Increments
547 Series: 3/4"x 1/2'-Ports and
1-1 /4" x 3/4" Ports
548 & 553 Series: 1-1 /2""x 1-1 /4 "
549 Series: 2-x 1-1 /2"" Ports
Performance of Stainless Steel Straight Centrifugal Pumps
[m] [ft.']
40 i
NPSHr
[ft.'] Im]
20 6
15 4
10 2
5 0
0 20 40 60 80 100 120 140 160 [U.S.gpml
0 4 8 12 16 20 24 28 32 36 [m'/h]
Capacity @ 3450 RPM (60 Hz)
(')Convert to psi, divide by 2.31 Liquid - Water specific gravity 1.0
F
36 120
32
100
28
624 80
s
320
F 60
16
12 40
8
20
4
0 0
�■■
I�
(�\`,.■
N�
e 400 Spring Street • Royersford, PA 19468 USA
AMT www.amtpump.com 888-amt-pump (268-7867)
A Gorman -Rupp Company For use with non/larmnable liquids compatible with pump component materials. Viton and Teflon' are registered trademarks of E I. Dupont.
Stainless Steel Straight Centrifugal Pumps
High Volume Pump Dimensional & Specification Data
Voltage
Full Load
Ship Wt.
Model
Curve
PH
ENC
@ 60 Hz+
Amps
SUC'
DIS'
A"
B"
C..D
E
F
L"
W
H
(lbs.)
5475-98
A
r3/4
1
ODP
115/230
814
3/4
1/2
WA
5.1 [13.0]
6.4 [16.3]
WA
2.1 [5.5]
4.1 [10.51
12.7 [32.2]
8.2 [20.81
7.8 [14.6]
23
5471-98
1
115/230
9/5
5.4 [13.8]
5.1 [13.0]
6.4 [16.3]
WA
2.1 [5.5]
4.1 [10.5]
13.7 [34.8]
10.2 [26.0]
7.8 [14.6]
38
5473-98
B
3
TEFC
230/460
3/2
1Ye
3/4
5.4 (13.8]
N/A
6.4 [16.31
WA
2.1 [5.5]
4.1 [10.5]
13.2 [33.5]
10.2 [26.0]
7.8 [14.6]
31
5481-98
1
115/230
12/6
5.4 [13.8]
5.1 [13.0]
6.0 [15.4]
WA
1.8 [4.6]
4.0 [10.2]
13.6 [34.5]
10.6 (26.9]
7.8 [14.6]
40
5483-98
C
1
3
TEFC
230/460
4/2
114
t
1 e
5.4 [13.8]
N/A
6.0 [15.4]
WA
1.8 [4.6)
4.0 [10.2]
12.2 [30.1 ]
10.6 [26.9]
7.8 [14.6)
35
5485-98
1
115/230
18/9
5.4 [13.8]
5.1 [13.0]
6.0 [15.4]
WA
1.8 [4.6)
4.0 [10.2]
14.1 [35.8]
10.6 (26.9]
7.8 [14.6]
49
5487-98
D
1%
3
TEFC
230/460
5/3
111
1t/e
5.4 [13.8]
WA
6.0 [15.4]
WA
1.8 [4.61
4.0 [10.2]
13.9 [35.3]
10.6 [26.9]
7.8 [14.6]
38
5491.98
1
115/230
22/11
5.4 [13.8]
5.0 [12.71
6.1 [15.6]
WA
1.8 [4.6)
4.0 [10.2]
14.9 [37.8]
10.6 [26.9]
7.8 [14.6]
51
E
2
TEFC
2
1Y2
5493-98
3
230/460
6/3
5.4 [13.8]
N/A
6.1 [15.6]
WA
1.8 [4.6]
4.0 [10.21
14.5 [36.81
10.6 [26.9]
7.8 [14.6]
44
5495-98
1
230
16
5.4 [13.8]
5.0 [12.7]
6.1 [15.6]
WA
1.8 [4.6]
4.0 [10.2]
15.4 [39.1]
10.6 [26.9]
7.8 [14.6]
60
5497-98
F
3
3
TEFC
230/460
8/4
2
1
5.4 [13.8]
WA
6.1 [15.6]
WA
1.8 [4.6]
4.0 [10.2]
15.0 [38.1]
10.6 [26.9]
7.8 [14.6]
48
High Volume
aut:TK M-
r w
�- A-
pal
i
_4p. �-
p
High Head
1,403 at
Mott
�[ xt,
2.
High Head Pump Dimensional & Specification Data
Voltage
Full Load
Ship Wt.
Model
Curve
HP
PH
ENC
@60Hz+
Amps
SUC'
DIS'
A"
B"
C"
D
E
F
L'•
W
H
(Lbs.)
5539-98
1
115/230
18/9
5.4 [13.81
5.1 [13.0]
7.5 [19.11
0.8 [z.11
2.5 [6.51
2.2 [5.61
15.5 [39.41
9.8 [24.8]
12.8 [27.21
54
5538-98
G
1 Yz
3
TEFC
230/460
5/3
1 Yz
1 Y<
5.4 [13.81
WA
7.5 [19.11
0.8 [2.1]
2.5 [6.51
22 [5.61
15.3 [38.81
9.8 [24.81
12.8 [27.21
44
5535-98
1
115/230
22/11
5.4 [13.8)
5.1 [13.01
7.5119.11
0.812.11
2.5 [6.51
2.2 [5.61
16.3 [41.61
9.8 [24.8]
12.8127.21
56
5537-98
H
2
3
TEFC
230/460
6/3
1
1
5.4 [13.81
WA
7.5 [19.1]
0.8 [2.1]
2.5 [6.51
2.2 [5.61
15.8 [40.1]
9.8 [24.8]
12.8 [27.2)
49
5531 98
1
230
16
5.4 [13.81
5.1 (13.0)
7.5 [19.1]
0.8 [2.1]
2.5 [6.51
2.2 [5.61
16.8 [42.61
9.8 [24.81
12.8 [27.21
65
I
3
TEFC
1
1 t/a
5533-98
3
230/460
8/4
5.4 [13.81
WA
1 7.5 [19.1]
0.8 [2.1]
2.5 [6.5]
2.2 [5.6]
16.3 [41.6]
1 9.8 [24.8]
12.8 [27.21
53
(') Standard NPT (Female) pipe thread.
r) This dimension may vary due to motor manufacturer's specifications.
(+) 3-Phase motors can also operate on 50 Hz. (This will change full load amps, service factor and RPM)
NOTE: Dimensions are in inches (centimeters) and have a tolerance of ± 1/4".
NOTE: Electric supply for ALL motors must be within ±10% of nameplate voltage rating (e.g. 230V ±10%= 207 to 253).
Standard Features
• Stainless Steel Construction
• Viton" Mechanical Seal and 0-ring, Optional Buna-N Seal
and 0-ring Available
• Investment Cast Stainless Steel Impeller
• Cast Iron Motor Adapter Provides Rigid Mounting
• AeroSpace Fusion Welding
Maximum Solids Handling Capacity: 1/8" Diameter
• Stainless Steel Motor Shaft & Hardware
• 1/2 to 3 HP NEMA 56J TEFC Single & Three Phase Motors
• NEMA Base Mounted Motors
• Maximum Working Pressure 150 PSI
• Maximum Temperature 200' F
• QSP - Quick Ship Pump for Many Models
Hazardous Duty/Xplosion Proof motors available from stock ranging from 1 to 10 HP; CALL FOR QUOTATION & LEAD TIME!
® Manufacturer of AMT & IPT Pumps
. 400 Spring Street • Royersford, PA 19468 USA
Vvww.amtpump.com • 888-amt-pump (268-7867) PUMP
The Gorman -Rupp Company reserves the right to discontinue any model or change specifications at any tins; without incurring any obligation. rr
A Gorman -Rupp Company C2012 American Machine and Tool Company. All rights reserved. 40R1111 RUPP• 1212
STE-14
Nik
PRM Diffused Aeration Systems M.
PRODUCT RECOVERY MANAGEMENT
Absolute Quality is our Goal... Genuine Service is our Habit!
PRM manufactures a series of skid
mounted Diffused Aeration Systems for
biological oxidation of contaminated
water.
Features:
• Skid Mounted, Steel Welded Frame
• Aluminum Welded Construction
• Functionally Designed Systems
PRM
Model
Water
Flow
Blower
HP
Air Flow
Baffles
Water
Air
Outlet
Skid Size
Aeration
Chamber Size
Inlet
Outlet
DA-50
50 GPM
3 HP
400 CFM
4
2" NPT
3" NPT
4"
4' X 8'
4' X 4'
DA-100
100 GPM
7.5 HP
800 CFM
5
3" FLG
4" FLG
8"
5' X 12'
4' X 8'
DA-250
250 GPM
20 HP
2000 CFM
5
4" FLG
6" FLG
10"
6' X 14'
5' X 12'
DA-500
500 GPM
30 HP
4000 CFM
10
6" FLG
10" FLG
12"
TX 23'
6' X 20'
DA-1000
1000 GPM
40 HP
8000 CFM
15
6" FLG
12" FLG
18"
8' X 30'
8' X 20'
** Options **
• Remote Telemetry
• Installation and maintenance services
• Customized systems for your specific project
requirements
Product Recovery Management, Incorporated
(888) TREAT -IT
888-873-2848 • 919-957-8890 • www.prm-net.com • sales(a)prm-net.com
Butner, NC • Webster, NY • Lakeland, FL
Actual equipment specifications may vary. Please contact Product Recovery Management, Inc. for additional details E-30
GAST MANUFACTURING, INC.
PART NUMBER:
REV.
A Unit I Corporation
o
• T
GAS
Post Office Box Box 97
Benton Harbor, Michigan
LTD 18 2
A
Ph: 269/926-6171
Product Specifications
Fax:269/925-8288
MAX VAC
MAX PRESS
NET WT.
MODEL NUMBER
MOTOR SPECIFICATIONS
RPM
HP
kW
'H20
mbar
'H20
mbar
lbs.
kg
208-230/460-60-3
3450
80
199
100
249
4.0
3.0
R6340R-50
112
51
190-220/380-415-50-3
2850
65
162
75
187
3.0
2,2
SOUND LEVEL 72/69 dB(A) MAX. ® 60/50 Hz
NORMAL AMBIENT -290C TO 400C ILL AND CSA APPROVED MOTOR FOR EXPLOSIVE
RELATIVE HUMIDITY 0% - 100% NON CONDENSING GAS ATMOSPHERES CLASS 1, GROUP D.
ENVIRONMENT CLEAN DUST FREE THIS BLOWER IS DESIGNED FOR SOIL AND GROUND
WATER REMEDIATION.
Product Performance TECHNICAL DATA SUBJECT TO
CHANGE WITHOUT NOTICE.
100
0 80
i
z_ 60
DW 40
V)
V)
W 20
o:
o_
III 1 1 1 1 n 11 1
25 50 75 10012515017520022
AIR FLOW SCFM
100
80
0
N
S 60
x
z
z
c 40
f
Z)
u 20
a
0
250
200
150
E
af 100
Z)
V)
V) so
W
o:
a_
250
200
150
O
n
E 100
F
D
DU 50
a
0 25 50 75 100 125 150 175 200 225 0
AIR FLOW SCFM
�C DENOTES RECOMMENDED
MAXIMUM DUTY
T9 T8 T7 T9 T8 T7
T3 T2 T1 T3 T2 T1
TO LINE TO LINE
LOW VOLTAGE HIGH VOLTAGE
3 PHASE NINE LEAD MOTOR
J
J
THERMOSTATS (TO
MOTOR PROTECTION
CIRCUIT)
............... ...............
: PERFORMANCE DATA
................. .......
••• 60 Hz••• THE PERFORMANCE DATA SHOWN WAS DETERMINED
: UNDER THE FOLLOWING CONDITIONS:
50 Hz:;• •::::::: ::
LINE VOLTAGE ® 60 Hz.230V OR 460V FOR 3 PHASE
.. ... UNITS. 115V OR 230V FOR 1 PHASE UNITS.
.................... ....
................... ...... ....
LINE VOLTAGE ® 50 Hz. 220V FOR 3 PHASE OR 1
PHASE UNITS.
50 100 150 200 250 300 350 400
AIR FLOW (m Vh) UNITS IN A TEMPERATURE STABLE CONDITION.
DELIVERY MEASUREMENTS MADE WITH OUTPUT PORT
60 Hz ;; THROTTLED.
o HZN SUCTION MEASUREMENTS MADE WITH INPUT PORT
THROTTLED.
TEST CONDITIONS: INLET AIR DENSITY ® 0.075 lbs. per
cu. ft. [20°C (68°F), 29.92' Hg (14.7 PSIA)1.
50 100 150 200 250 300 350 400 NORMAL PERFORMANCE VARIATIONS ON THE RISISTANCE
AIR FLOW (m 3/h) CURVE WITHIN *10% OF SUPPLIED DATA CAN BE EXPECTED.
Product Dimensions mm / inches
478 389
LIFTING PLATE 15.30
18.82 CAN BE TURNED
OR REMOVED
AFTER BLOWER
INSTALLATION. r- 3/4 NPT
98 i 140
3.85 404 5.50
15.89
2x 2' NPT
15 FULL R.
59
11.42
REF. 1138
' REF.
TYP. (4)
391
15.38
197
7.75
_I 125 L
') �`
13
4.92
.52
289
11.36
290
11.42
329
12.96
K�.
ciu5cu iiiiNciici nianiiniLca Nciiuiiiiawc.
Pumps are close coupled to Totally Enclosed
Fan Cooled (TEFC) or Open Drip Proof (ODP)
motors. Pumps are not self -priming and
require flooded suction.
H gn neat" *gratym
Centrik9a/ Pumps
300 Series Investment Cast
Stainless Steel, Cast Bronze and
/`act /rIMn /ife�ctrii�tinrrs urrith
Id
d
Ind
leis
[e
its
"Ports
teller
5 PSI)
nps
NPSHr
Ift.'] [m]
30 8
20 4
10
0 0
0 10 20 30 40 50 60 70 80 90 100 110 120 130 [U.S.gpm]
0 4 8 12 16 20 24 28 [m31h]
Capacity @ 3450 RPM (60 Hz)
t (`IConvert to psi, divide by 2.31 Liquid - Water specific gravity 1.0
400 Spring Street - Royersford, PA 19468 USA
AM T www.amtpump.com 888-amt-pump (268-7867)
n Gorman -Rupp Company For use with nonflammable liquids compatible with pump component materials. Viton, and Teflon" are registered trademarks of E. I. Dupont.
p'wm• a om� High Head Straight
Pump Dimensional & Specification Data
Voltage
Full Load
# Ship Wt.
Model#
Curve
HP
PH
ENC
@ 60 Hz+
Amps
SUC*
OIS*
A**
B**
C**
D
E
F
L**
W**
H
(Lbs.)
4893
1/2
1
ODP
115/230
10/5
11/4
1
N/A
5.1 [13.0]
7.4 [18.9]
0.2 [0.6]
2.1 [5.3]
3.3 [8.5]
14.0 [35.51
8.2 [20.8]
8.6 [21.8]
43
489C
A
3/4
1
TEFC
115/230
9/5
1 %
1
5.4 [13.81
5.1 [13.0]
7.4 [18.91
0.2 [0.6]
2.1 [5.3]
3.3 [8.51
14.7 (37.3]
10.0 [25.4]
8.6 [21.81
51
4890
3/4
3
TEFC
230/460
312
114
1
5.4 [13.81
WA
7.4 [18.91
0.2 [O.6]
2.1 [5.31
3.3 [8.5]
14.2 [36.01
10.0 [25.41
8.6 [21.81
43
489E
1
1
TEFC
115/230
12/6
11/4
1
5.4 [13.81
5.1 [13.0]
7.4 [18.9]
0.2 [0.6]
2.1 [51
3.3 [8.51
14.9 [37.8]
10.0 [25.4]
8.6 [21.81
57
489E
B
1
3
TEFC
208-230/460
312
11/4
1
5.4113.81
WA
7.4118.91
0.2 [0.6]
2.1 [5.31
3.3 [8.913.5
[34.3]
10.0 [25.4]
8.6 [21.81
47
4690
1
1
ODP
111/230
17/9
1'/4
1
N/A
5.1 [13.01
8.1 [20.61
0.2 [0.6]
2.1 [5.3]
3.3 [8.914.7
[37.31
8.2 [20.8]
8.6 [21.81
54
489A
C
l Y2
1
TEFC
115/230
19/9
11/4
1
5.4 [13.81
5.1 [13.01
7.4 [18.91
0.2 [0.6]
2.1 t5.31
3.3 [8.51
15.4 [39.11
10.0 (25.4]
8.6 [21.81
61
489E
1 Y2
3
TEFC
2301460
5/3
11/4
1
5.4 [13.8]
WA
7.4 [18.9]
0.2 [0.6]
2.1 [5.3]
3.3 [8.5]
15.2 [38.6]
10.0 [25.4]
8.6 [21.8]
1 50
4902
1'1 i
1
OOP
115/230
22/11
1Y2
11/4
N/A
5.1 [13.01
8.7 [22.11
0.5 [1.4]
3.0 [7.6]
3.4 [8.9]
15.8 [40.11
8.7 (22.1]
9.0 [22.8]
58
490C
D
2
1
TEFC
115/230
22/11
1Y2
11/4
5.4 [13,81
5.1 [13.01
8.0 [20.41
0.5 [1.4]
3.0 FBI
3.4 [8.9]
16.8142.6]
10.2 [25.91
9.0 [22.8]
66
490D
2
3
TEFC
230/460
6/3
1 Y2
11/4
5.4 [13.81
WA
8.0 [20.41
0.5 [1.4]
3.0 [7.61
3.4 [8.9]
16.3 [41.41
10.2 [25.9]
9.0 [22.81
59
4904
2
1
ODP
115/230
28/14
1Y2
11/4
WA
5.1 [13.01
8.7122.11
0.5 [1.4]
3.0 t7.61
3.4 [8.9]
15.8 [40.11
8.7 [22.1]
9.0 [22.81
66
490A
E
3
1
TEFC
230
16
1 Y2
1'/
5.4 [13.81
5.0 [12.7]
8.0 [20.4]
0.5 [1.4]
3.0 [7.61
3.4 [8.9]
17.3 [43.91
10.2 [25.91
9.0 [22.8]
75
490B
3
3
TEFC
230/460
814
1 h
11/4
5.4 [13.8]
WA
8.0 [20.41
0.5 [1.4]
3.0 t7.6]
3.4 [8.9]
16.8 [42.61
10.2 [25.9]
9.0 [22.8]
63
4900
3
1
ODP
230
18
1Y2
1 A
WA
5.0 [12.7]
8.7 [22.11
0.5 [1.4]
3.0 [7.61
3.4 [8.9]
17.1 [43.4]
8.7 [22.1]
9.0 [22.81
73
4901
F
3
3
ODP
208-230/460
9/5
1 Y2
11/4
N/A
WA
8.0 [20.4]
0.5 [1.4]
3.0 [7.6]
3.4 [8.9]
16.8 [42.6]
8.7 [22.11
9.0 [22.81
73
C) Standard NPT (Female) pipe thread.
(*I This dimension may vary due to motor manufacturer's specifications.
(+) 3-Phase motors can also operate on 50 Hz. (This will change full load amps, service factor and RPM)
NOTE: Dimensions are in inches (centimeters) and have a tolerance of ± 1/4".
NOTE: Electric supply for ALL motors must be within ±10% of nameplate voltage rating (e.g. 230V ±10%= 207 to 253).
# When Ordering, Add the Correct
(-9X) Suffix to Model Number Indicating
Material Selection (Ex. 4893-95)
XCI (-95) Cast Iron Construction with
Buna-N Seals
XB (-97) Cast Bronze Construction with
Viton® Seals
XSS (-98) Cast Stainless Steel Construction
with Viton® Seals
(All Models Come Standard with Stainless
Steel Impeller)
Standard Features
Maximum Solids Handling Capacity:1/8" Diameter
• Stainless Steel, Bronze and Cast Iron Construction • High Efficiency Closed Stainless Steel Impeller
• Buna-N or Viton' Mechanical Sea[ and 0-ring, Depending • Discharge Rotates in 90' Increments
on Mode[ • Maximum Working Pressure 150 PSI
• Optional Silicon Carbide Mechanical Seals Available • Maximum Temperature
• Stainless Steel Motor Shaft and Hardware • Viton'W 200' F
• NEMA TEFC Single or Three Phase 3450 RPM Motors,
• Buna-N 180° F
Optional ODP Motors Available • (4) Front Drain Plugs, Located 90' Apart
• NEMA Base Mounted Motor • QSP - Quick Ship Pump for Many Models
Hazardous Duty/Xplosion Proof motors available from stock ranging from 1 to 10 HP; CALL FOR QUOTATION & LEAD 11ME!
® Manufacturer of AMT & IPT Pumps
. 400 Spring Street • Royersford, PA 19468 USA
www.amtpump.com • 888-amt-pump (268-7867) PUMP
The Gorman -Rupp Company reserves the right to discontinue any model or change specifications at any time without incurring any obligation.
A Gorman -Rupp Company C2012 American Machine and Tod Company. All rights reserved. GORNtAN�{IIPP" 1212
STE-10
PRM Bag Filter Housings -
Low Pressure Banded Housing 'ACN•
PRODUCT RECOVERY MANAGEMENT
Absolute Quality is our Goal... Genuine Service is our Habit!
Absolute Quality: PRM provides banded
top style bag filter housings for your
remediation and industrial filtration
needs. Our units come standard in
stainless steel and are available as a
stand- alone bare unit or completely
plumbed and ready to go when it
reaches the project site.
Typical Features Include:
• 304 Stainless Steel Construction
• 8"x 30" Trade Size # 2 Housing
• 2" NPT Inlet and Outlet Connections
• Viton® 0-rings standard
• 100 psi Maximum Working Pressure
• Stainless Steel Strainer Basket and
Internal Bag Support Rack
• Drain Port and Mounting Stand
• Quick Opening Clamp Top
• Safety Release Vent for Maintenance
q
* * Options and Services * *
• Skid Mounting, Pre Plumbed Filter Arrays
• Steel, Stainless Steel, or PVC Piping with Valves
• Custom Integration Into Existing Systems
• Design Assistance
• Field Installation, Startup, and Operations
• Replacement Bag filters available in stock
(5, 10, 25, 50, and 100 Micron rated filters)
• Custom Built Filter Packages Per Your Specs
Product Recovery Management, Incorporated
(888) TREAT -IT
888-873-2848 • 919-957-8890 • www.prm-net.com • sales(a)-prm-net.com
Butner, NC • Webster, NY • Lakeland, IF
* Actual equipment specifications may vary. Please contact Product Recovery Management, Inc. for additional details. E-13(1A)
PRM Bag Filter Housings -
Low Pressure Banded Housing
Product Name PRM Part No.
Bag Filter Housings 800, DBFSFGX2HBFL2
304 SS, 2" NPT In/Out
Dual System Skid
4=Nar.-I
PRODUCT RECOVERY MANAGEMENT
Absolute Quality is our Goal... Genuine Service is our Habit!
Product Name PRM Part No.
s
Bag Filter Housing 8x30, DBFHBFL2
304 SS, 2" NPT In/Out
Single Housing Only
Product Name
PRM part no.
100 Micron Bag Filters #2
DBFPE100P2S
DBFPE50P2S
DBFPE25P2S
DBFPE10P2S
TDBFPE5P2s
50 Micron Bag Filters #2
25 Micron Bag Filters #2
10 Micron Bag Filters #2
5 Micron Bag Filters #2
Product Recovery Management, Incorporated
(888) TREAT -IT
888-873-2848 - 919-957-8890 - www.prm-net.com - sales(Mprm-net.com
Butner. NC - Webster. NY - Lakeland. FL
* Actual equipment specifications may vary. Please contact Product Recovery Management, Inc. for additional details. E-13(113)
PRM Carbon Svstems PR
s
PRODUCT RECOVERY MANAGEMENT
PRM offers carbon systems for Groundwater
Remediation and Industrial Process Systems.
Vapor Phase Carbon Systems are designed for
the removal of contaminants from industrial and
remediation air streams.
Liquid Phase Carbon Systems are built to adsorb
contaminants from groundwater.
Absolute Quality:
• In-house Manufactured Carbon Vessels
• Heavy Duty Bases or Forks for Stability and
Ease of Use
• Inlet and Outlet Diffusers for Even Flow and
Excellent Backwash Ratios
• Heavy Duty Carbon Steel, Aluminum, or
Fiberglass Units Available
• UV Resistant Coated Exterior
• Single Bolt Gasketed Manway for Easy
Maintenance
PRM offers standardized, pre-engineered
systems, or can customize a carbon system to
specific project site requirements.
PRM can supply virgin and/or reactivated
liquid phase or vapor phase Granular
Activated Carbon for all of your environmental
remediation projects. Ask about carbon
change out service for existing systems.
sales@prm-net.com
Absolute Quality is our Goal... Genuine Service is our Habit!
Ctl!•RATINO
81
YEARS
PRODUCT RECOVERY MANAGEMENT
Product Recovery Management, Incorporated
(888) TREAT -IT
888-873-2848 • 919-957-8890 • www.prm-net.com • sales(a-)_prm-net.com
Butner, NC • Webster, NY • Lakeland, FL
* Actual equipment specifications may vary. Please contact Product Recovery Management, Inc. for additional details. E-05
4
10
PRM Liquid Phase Carbon Units M 41
PRODUCT RECOVERY MANAGEMENT
Absolute Quality is our Goal... Genuine Service is our Habit!
4 Liquid Phase Carbon Units:
3.5
a 3 Pre Engineered for Ranges of:
a 2.5
a
2 • 10 GPM to 250 GPM
1.5 90lbs to 4000lbs Sizes
0.5 f` 3/4" to 4" Inlet/Outlet
0
0 5 10 15 20 25 30 35 40 45 Uses 8x30 GAC
Flow (GPM)
�- HP-90 HP-125 HP-200
4
3.5
H P-90 H P-1000
a 25
° 2
1.5 X ' HP-1 25 H P-2000
3
a"`S
a 1 all -` H P-200 H P-2500
0.5
0 HP-250 H P-3000
0 10 20 30 40 50 60 70 s0
Flow (GPM) H P-500 H P-4000
--HP-250 HP-500
1.4 1.4
s
1.2 1 2
a 1 i 1
S 0.6 0 0.
0 0
.0.6
a 0.4 / d 0.4
a , a
0.2 0.2
0 0
0 20 40 60 80 100 120 140 0 50 100 150 200 250 300
Flow (GPM) Flow G(PM)
--41- HP-1000 HP-1000 High Flow ---W HP-2000 HP-2000 High Flow
Product Recovery Management, Incorporated
(888) TREAT -IT
888-873-2848 - 919-957-8890 - www.prm-net.com - sales(a)prm-net.com
Butner, NC - Webster, NY - Lakeland, FL
* Actual equipment specifications may vary. Please contact Product Recovery Management, Inc. for additional details. E-05
PRM Multi -Jet Water Meters PR
PRODUCT RECOVERY MANAGEMENT
Water Meters for Totalization and
Rate Indication with Pulse Output
PRM multi jet water meters are known for
their wide range, simplicity, and accuracy in
low quality water.
Absolute Quality:
• Pulse Output Components
• All Meters have Hydrocarbon Resistant
Seals and will not be damaged by
dissolved amounts of free product
• Sealed Dry Dial for Clear Readings
• Internal Strainer to Protect Meter from
Particulate Damage
• Magnetic Drive for lower resistance
Changing the pulse rate requires no
special tools and can be done in the field.
Specifications:
Class: B
Accuracy: Transitional Flow: ± 5%
Nominal Flow: ± 2%
Maximum Water Temperature: 104°F
Maximum Water Pressure: 232 psi
Mounting Orientation: Horizontal
PRM Part Number: Description
WM050PVX—
1/2" NPT multi -jet water meter
WM075PVX—
3/4" NPT multi -jet water meter
WM100PVX-1"
NPT multi jet water meter
WM1 25PVX—
1-1/4" NPT multi jet water meter
WM200PVX—
2" NPT multi -jet water meter
Absolute Quality is our Goal... Genuine Service is our Habit!
16
14
12
10
6
� 6
N
4
a
2
0
Head Loss Curve
0 20 40 60 80 100 120 140
Flow Rate (GPM)
Materials:
Body: Brass, polyethylene
Couplings: Brass
Measuring Chamber: Polyethylene
Paint: Epoxy Coated
Seal: Black: Buna-N, White: HDPE
Mounting Orientation: Horizontal
Not for use with Potable Water
Product Recovery Management, Incorporated
8( 88) .TREAT -IT
888-873-2848 • 919-957-8890 • www.prm-net.com • sales(&prm-net.com
Butner, NC • Webster, NY • Lakeland, FL
* Actual equipment specifications may vary. Please contact Product Recovery Management, Inc. for additional details. P-20
PRM Multi -Jet Water Meters =%N;n•
PRODUCT RECOVERY MANAGEMENT
Absolute Quality is our Goal... Genuine Service is our Habit!
.w«. cv nrm.nwt com
Materials:
Body: Brass, polyethylene
Couplings: Brass
Measuring Chamber: Polyethylene
Paint: Epoxy Coated
Seal: Black: Buna-N, White: HDPE
Mounting Orientation: Horizontal
Not for use with Potable Water
Max. Flow
Nom. Flow Range
Pulse
Part #:
Size:
*Length (in)
Height (in)
Weight (lbs)
Gallons Per Minute
WM050PVX
1/2" NPT
10.5
4.75
3.0
10
1-10
10 gal/pulse
WM075PVX
3/4" NPT
12
4.75
3.5
20
1-20
10 gal/pulse
WM100PVX
1" NPT
15
4.5
5.5
30
2-30
10 gal/pulse
WM125PVX
1-1/4" NPT
15
5
6
50
3-50
10 gal/pulse
WM200PVX
2" NPT
17.5
6.5
1 14
1 130
1 50-130
100 gal/pulse
*Water Meter body plus the Inline NPT fittings. Fittings add approximately 4" to overall length (2" per end).
Product Recovery Management, Incorporated
(88 ) TREAT -IT
888-873-2848 • 919-957-8890 • www.prm-net.com • sales(&prm-net.com
Butner, NC • Webster, NY • Lakeland, FL
* Actual equipment specifications may vary. Please contact Product Recovery Management, Inc. for additional details. P-20
V SERIES • LIGHTING
INCANDESCENT NEMA 4 - CLASS 1, DIV. 2 ALUMINUM FIXTURES
0
v—
09111111
Class I, Div. 2, Groups A,B,C,D 2
Class I, Zone 2, Groups IIC,IIB,IIA
NEMA 3,4
Listed - File E10514
UL-1571 Standard for incandescent fixtures
UL-844 Standard for hazardous location fixtures
�• Certified - File LR11713
PENDANT MOUNT WITH VGA SPLICE BOX
CATALOG NUMBER
CONSISTS OF
FIXTURE
LAMP
HUB
FIXTURE W/
MOUNTING
FIXTURE
CLEAR
GUARD
TYPE
WATT
SIZE
GLOBE &GUARD
BOX
BODY
GLOBE'
100
150
1/2
VUAGG-1-100PX t-
VGA-1
VXFC-100 N34
VCGP-100
VAG-100
3/4"
VUAGG-2-100PX
VGA-2
VXFC-100 N34
VCGP-100
VAG-100
200
300
1/2
VUAGG-1-200PX
VGA-1
VXFC-200 N34
VCGP-200
VAG-200
3/4"
1 VUAGG-2-200PX
VGA-2
VXFC-200 N34
VCGP-200
VAG-200
CEILING FIXTURE WITH VGX SPLICE BOX
CATALOG NUMBER
CONSISTS OF
FIXTURE
LAMP
HUB
FIXTURE W/
MOUNTING
FIXTURE
CLEAR
GUARD
TYPE
WATT
SIZE
GLOBE & GUARD
BOX
BODY
GLOBE*
100
150
112"
VUXGG-1-10OPX CV
VGX-1
VXFC-100 N34
VCGP-100
VAG-100
3/4"
VUXGG-2-100PX O
VGX-2
VXFC-100 N34
VCGP-100
VAG-100
20!
300
1/2"
VUXGG-1-200PX T
VGX-1
VXFC-200 N34
VCGP-200
VAG-200
3/4"
VUXGG-2-200PX)
VGX-2
VXFC-200 N34
I VCGP-200
I VAG-200
CEILING FIXTURE WITH MOUNTING FEET USING VBC SPLICE BOX & VBA ADAPTER
CATALOG NUMBER
CONSISTS OF
FIXTURE
LAMP
HUB
FIXTURE W/
MOUNTING
FIXTURE
CLEAR
GUARD
TYPE
WATT
SIZE
GLOBE & GUARD
BOX/ADAPTER
BODY
GLOBE*
100
150
112
VUXBGG-1-100PX O
VBC-1+VBA
VXFC-100 N34
VCGP-100
VAG-100
3/4"
VUXBGG-2-100PX ,O
VBC-2+VBA
VXFC-100 N34
VCGP-100
VAG-100
200
300
1/2
VUXBGG-1-200PXO
I VBC-1+VBA
VXFC-200 N34
VCGP-200
VAG-200
VUXBGG-2-200PXO
I VBC-2+VBA
I VXFC-200 N34
I VCGP-200
VAG-200
WALL FIXTURE WITH MOUNTING FEET USING VBC SPLICE BOX & VB ELBOW
CATALOG NUMBER
CONSISTS OF
FIXTURE
LAMP
HUB
FIXTURE W/
MOUNTING
FIXTURE
CLEAR
GUARD
TYPE
WATT
SIZE
GLOBE & GUARD
BOX/ELBOW
BODY
GLOBE*
100
150
1/2
VFBGG-1-100PX:1)
VBC-1 + V13-1
VXFC-100 N34
VCGP-100
VAG-100
3/4"
VFBGG-2-100PXO
VBC-2 + V13-2
VXFC-100 N34
VCGP-100
VAG-100
200
300
1/2
VFBGG-1-200PX O
VBC-1 + VB-1
VXFC-200 N34
VCGP-200
VAG-200
3/4"
VFBGG-2-200PX(1)
1 VBC-2 + V13-2
VXFC-200 N34
VCGP-200
VAG-200
r �dL "For other colors, order globes and mounting components separately.
+D Fixture supplied as component unit pack when ordered by this catalog number.
KIL LARK O See page L9 for temperature codes; NEMA 3, 4 when used with tempered glass.
AX SERIES MOTOR
EXPLOSION PROOF MOTOR
DIMENSIONS
n n
1
I
MODEL
AX08
14 3/4"
11 3/4"
61/2"
-
AX10
14 3/4"
11 3/4"61/2"
-
AX12
16 3/4"
13 3/4"
F5"
11"
13 3/4"
AX14
18 3/4"
15 3/4"
11"
13 3/4"
AX16
20 3/4"
17 3/4"
11"
13 3/4"
AX18
223/4"
193/4"
5
11 1/4"
14"
AX20
24 3/4"
21 3/4"
5"
11 1/4"
14"
AX24
28 3/4"
25 3/4"
5"
11"
13 3/4"
AX30
351/4"
323/4"
5"
13 1/4"
AX36
411/4"
1 383/4"
1 5"
131/2"
-
— Explosion Proof Motor
AX - SHUTTER MOUNTED FANS
Designed for Industrial, Commercial & Farming applications.
The AX series exhaust fan is a sturdily constructed, direct drive, horizontal discharge fan that
is typically use for general ventilation of factories, garages, warehouses and other industrial or
commercial buildings. The AX fans are available in multiple single -speed variations as well as
two -speed and variable speed models.
The AX series housings are constructed of heavy duty aluminum with built in shutters that
automatically open when the fan starts and gravity closes when the fan stops.
FEATURES
Sturdily constructed from all -aluminum extrusions. Cpq
Heavy duty OSHA motor mount/guard is standard. �](7
Heavy gauge, welded steel rod with plated finish. c us
Totally enclosed air over motor with overload protection.
SINGLE
PHASE
THREE BLADE
PHASE DIAMETE
.1' VOIXAGE
PHASE1 PHAsEj
AM
PHASE)
,G,- ,B(A) I'M @ STATIC PRESSURE FRAMING
@5 ft L__C DIMENSIONS
OAO' 0.10" 0.125" 0.25"
AX12.1V
VARIABLESINGLE SPEED -
AX12-1* 12"
1700 113 115/230
5.02.5
26 63 1650 1560 1525 1 1400 14' X 14'
AX12-1VHE
12'
1450 1115 115
1.0
22 60 1350 1290 1275 1150 14'X 14'
AX14-1V
AX14-1' 14'
1700 1/3 115/23D
5.02.5
29 67 2170 2030 1950 1900 16' X 16'
AX14-IVHE
- 14•
1450 1/15 116
1.0
25 64 1600 1525 15M 1300 16' X 16'
AX16-1V
AX16.1' 16,
1700 1/3 115/230
5.0/2.5
30 68 2570 2470 2410 1 18' X 18'
AX16-1VHE
16,
1450 1/15 115
1.0
26 63 1850 1750 1700 1550 18' X 18'
AX18-1V
AXIS-1' 18'
1700 1/3 115/230
3.8/1.9
36 71 3150 3000 29M 2575 20'X 20'
AX20.1V
AX2011• 20'
1700 1/3 115230
3N1.9
39 77 3620 3420 3340 3120 22'X22'
AX24-IV
AX24-1• 24'
1100 1/2 115230
6A/32
43 72 5500 5400 5310 5100 26'X 26'
1625
1 1/4 116
1.8
27 63
1640 l 1540 _
1510
1390
14' X 14'
AX12-2
—
12'
AX14-2
—
14'
1625
1/4 115
1.8
30 67
2170 2071
2030
1860
16' X 16'
AX16-2
—
16,
1625
1/4 115
1.8
31 68
2370 2270
2210
2000
18'X 18,
AX18-2
—
18,
1625
113 115
4.0
37 73
3200 3090
3040
2920
20' X 20'
AX20-2
—
20'
1625
1/3 115
4.0
39 77
3420 3220
3170
2920
22' X 22'
AX24-2
—
24'
1100
1/3 115
5.4
45 70
5000 4500
4300
3600
26' X 26'
AX30-2
—
1.
1100
12 115/230
6.4/32
72 82
8000 7.
6000
5000
.' X.-
AX36-7
—
36'
850
12 115230
6.6/3.3
88 72
12000 11000
10500
9500
39' X 39'
AX08-3
—
8'
1600/13M
1140 115
0.5
14 1 48
400/330
320260
280/230
180/140
12' X 12'
AX10-3
—
10'
1600/1300
1/40 115
0.5
14 56
690/580
590/460
570/390
550/340
12' X 12'
AX12-3
—
12'
1725/1140
114 115
3.4
27 64
1670/1100
1600/950
1575900
145OW
14' X 14"
AX14-3
—
14'
1725/1140
1/4 115
3.4
31 67
2190/1440
2080/1325
2000/1300
1950/850
16' X 16'
AX16-3
—
16'
1725/1140
1/4 115
3.4
34 89
2580/1 T70
2480/1620
2430/1560
2270/1020
18'X 18'
AX18-3
—
18'
1725/1140
1/3 115
5.3/2.9
38 74
3200/2310
3050/2030
2950/1960
2625/1750
20'X20'
AX20-3
—
20'
1725/1140
1/3 115
5.3/2.9
41 77
36402420
34402270
3360WO
3140MB90
22'X22'
:•
AX124
AX/24'
12'
1725
1/3
115/208-230
6.613.1-3.3
49 63
1670
1600
1575
1460
14' X 14'
AX144
AX144•
14'
1725
1/3
1151208-230
6.6/3.1-3.3
49 67
2190
2080
2000
1950
16' X 16'
AX1&4
AX164•
16'
1725
1/3
115/208-230
6.613.1-3.3
51 68
2580
2490
2430
2270
18' X 18'
AX184
AX184•
18'
1725
1/3
115'208-230
6.6/3.1-3.3
56 1 73
3200
3050
2950
2625
20'X20'
AX204
AX20.4•
1.
1725
1/3
115208-230
6.6/3.1-3.3
57 77
3640
3440
3360
3140
22'X22'
AX244
AX244•
24'
1725
1/3
115/208-230
6.6/3.1-3.3
57 77
I 5520
5410
1 5330
5130
26'X 26'
oree phase motors, substitute "*" with "M" for 208-230/460 volt or "P" for 575 volt
Other voltages in single or three phase are available. 50HZ voltages are available. Consult factory.
f)=1; 115 Speed controls Front guard
Thermostats Weather hoods
For a complete listing on all available accessories, see page 15.
For a complete listing of all available hoods, see page 11.
For a complete listing of all available control options, see pages 25-26.
SORIES ACCESSORIES FOR AX & P SERIES FANS
FRONT GUARD FOR AX & P SERIES FANS
18 gauge galvanized 3/4" expanded metal screen.
FITS FAN
FRONT GUARD
8"
XFG8-10
10"
XFG8-10
12"
XFG12
14"
XFG14
16"
XFG16
18"
XFG18
20''
XFG20
24"
XFG24
30''
XFG30
36"
XFG36
PANEL SLEEVES FOR P SERIES
Sleeves are 9 112" deep.
8"
PSL08
10"
PSL10
12"
PSL12
14"
PSL14
16'
PSL16
18"
PSL18
20"
PSL20
24"
PSL24
30"
PSL30
36"
PSL36
REPLACEMENT GUARDS
FAN
MODELFITS
8"
2X115
8" - 10" OSHA motor mount
10"
2X115
8" - 10" OSHA motor mount
12"
2X116
12" OSHA motor mount
14"
2X117
14" - 16" OSHA motor mount
16"
2X117
14" - 16" OSHA motor mount
18"
2X118
18" - 20" OSHA motor mount
20"
2X118
18" - 20" OSHA motor mount
24"
2X119
24" OSHA motor mount
30"
2X113
30" OSHA motor mount
36"
2X114
36" OSHA motor mount
MOTORIZED & GRAVITY DAMPERS FOR FRESH AIR INTAKE
BACK DRAFT DAMPER
The Motorized dampers listed above are 110V.
For 230V, replace X with Y.
For 24V AC, replace X with Z.
MOTORIZED DAMPER
CVTP
Explosion Proof
Convection Heater
• 1.6 - 9 kW
• 5,459 - 30,708 Btuh
• 120, 208, 240, 277, 480 and
575 Volt
• 1 & 3 Phase
• Built-in & Prewired Control
Options
• UL Listed and CSA Certified for
Class 1, Division 1 or 2, Group
B, C & D Environments
• CE Approved Models Available
Description
Type CVEP explosion proof convection heater
is designed to provide a rugged, corrosion -
resistant heat source for areas where volatile
flammable liquids, gases or vapors are
present. All basic models without controls
are UL listed and CSA certified for use in
areas designated as Class 1, Division 1 or 2
Group B, C or D locations.
Applications
• Petroleum Refineries, Gasoline Storage and
Dispensing Areas
• Industrial Areas Using Flammable Liquids
in Dip Tanks
• Petroleum Refineries
• Dry Cleaning Plants
• Utility and Natural Gas Plants
• Aircraft Hangers/Fueling Areas
• Solvent Extraction Plants
• Storage Areas for Flammable Products or
Batteries
• Sewage Treatment Plants
• Hydrogen Atmospheres
c *us
SP°
C E
Dimensions (Inches)
A 9
Ilfllllllflfffflll
•-----===—�aa—aa;a=
B
•
3-1/4
5-1/8
c
Dimensions (Inches)
1.6, 1.8 and 3.6
34 20
9
3.2 and 7.6
58
20
9
4.0, 4.5 and 9.0
70
20
9
Construction
Cabinet — Sloped top, constructed of heavy
16 gauge steel, polyester powder coated for
maximum corrosion resistance.
Explosion Proof Junction Box — For conduit
entry and ease of power wiring.
Heating Elements — Sealed, metal sheath,
heavy-duty, low watt density, enclosed high
grade resistance wire embedded in MgO
refractory core. Elements are inserted in a
copper tube with aluminum fins.
Features
Integral Mounting Brackets allow for easy wall
installation.
Sloped Top Cabinet ensures maximum
ventilation by preventing objects from being
placed on the top which would restrict air flow.
Designed for Areas Classified
• Class I, Division 1 or 2, Groups B, C, D
• Temperature Code T3A 1800C (356°F) or
T2A 280°C (536°F)
Optional Features (Factory Installed)
• Thermostat
• Magnetic Contactor
• Control Voltage Transformer
Advantages
• Easy Installation
• Clean, Safer Heat Source
• Pre -Wired Control Options
Refer to • Long Life
WR-80EP
in the Controls section.
Chromalox
CVEP
Convection Heater
For Hazardous
Locations
Specifications and Ordering Information
Temperature Code T3A (356°F, 180°C) Group B, C, and D
1.6
208
1
7.7
5,500
CVEP-16-81-00-00
NS
088336
58
1.6
208
3
4.5
5,500
CVEP-16-83-00-00
NS
086844
58
1.6
240
1
6.7
5,500
CVEP-16-21-00-00
NS
086852
58
1.6
240
3
3.8
5,500
CVEP-16-23-00-00
NS
086860
58
1.6
277
1
5.8
5,500
CVEP-16-71-00-00
NS
086879
58
1.6
480
1
3.3
5,500
CVEP-16-41-00-00
NS
086887
58
1.6
480
3
1.9
5,500
CVEP-16-43-00-00
NS
086895
58
1.6
575
1
2.8
5,500
CVEP-16-61-00-00
NS
086908
58
3.2
208
1
15.4
11,000
CVEP-32-81-00-00
NS
086916
94
3.2
208
3
9.0
11,000
CVEP-32-83-00-00
NS
086924
94
3.2
240
1
13.3
11,000
CVEP-32-21-00-00
NS
086932
94
3.2
240
3
7.7
11,000
CVEP-32-23-00-00
NS
086940
94
3.2
277
1
11.6
11,000
CVEP-32-71-00-00
NS
086959
94
3.2
480
1
6.7
11,000
CVEP-32-41-00-00
NS
086967
94
3.2
480
3
3.8
11,000
CVEP-32-43-00-00
NS
086975
94
3.2
575
1
5.6
11,000
CVEP-32-61-00-00
NS
086983
1 94
4
208
1
19.2
13,600
CVEP-40-81-00-00
NS
086991
112
4
208
3
11.1
13,600
CVEP-40-83-00-00
NS
087003
112
4
240
1
16.7
13,600
CVEP-40-21-00-00
NS
087011
112
4
240
3
9.6
13,600
CVEP-40-23-00-00
NS
087020
112
4
277
1
14.4
13,600
CVEP-40-71-00-00
NS
087038
112
4
480
1
8.3
13,600
CVEP-40-41-00-00
NS
087046
112
4
480
3
4.8
13,600
CVEP-40-43-00-00
NS
087054
112
4
575
1 1
7
13,600
CVEP-40-61-00-00
NS
1 087062
1 112
Temperature Code T2A (536°F, 280°C) Group B, C, and D
1.8
1.8
1.8
1.8
1.8
1.8
1.8
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
7.6
7.6
7.6
7.6
7.6
7.6
7.6
7.6
1.8
1.8
1.8
1.8
1.8
3.6
3.6
3.6
208
1
8.7
6,140
208
3
5
6,140
240
1
7.5
6,140
240
3
4.4
6,140
277
1
6.5
6,140
480
1
3.7
6,140
480
3
2.2
6,140
208
1
17.3
12,300
208
3
10
12,300
240
1
15
12,300
240
3
8.7
12,300
277
1
13
12,300
480
1
7.5
12,300
480
3
4.3
12,300
575
1
6.3
12,300
208 3 21.1 24,000
240 1 31.7 24,000
240 3 18.3 24,000
277 1 27.4 24,000
480 1 15.8 24,000
480 3 9.2 24,000
575 1 13.2 1 24,000
208 1 43.3 30,700
208 3 25 30,700
240 1 37.5 30,700
240 3 21.7 30,700
277 1 32.5 30,700
480 1 18.8 30,700
480 3 10.8 30,700
575 1 1 1 15.7 1 30,700
CVEP with Built-in Thermostat
120 1 15 6,140
208 1 8.7 6,140
240 1 7.5 6,140
277 1 6.5 6,140
480 1 3.7 6,140
208 1 17.3 12,300
240 1 15 12,300
480 1 7.5 12,300
CVEP-1 8-81 -00-00
CVEP-18-83-00-00
CVEP-1 8-21 -00-00
CVEP-18-23-00-00
CVEP-18-71-00-00
CVEP-18-41-00-00
CVEP-18-43-00-00
CVEP-36-81-00-00
CVEP-36-83-00-00
CVEP-36-21-00-00
CVEP-36-23-00-00
CVEP-36-71-00-00
CVEP-36-41-00-00
CVEP-36-43-00-00
CVEP-36-61-00-00
CVEP-76-81-00-00
CVEP-76-83-00-00
CVEP-76-21-00-00
CVEP-76-23-00-00
CVEP-76-71-00-00
CVEP-76-41-00-00
CVEP-76-43-00-00
CVEP-76-61-00-00
S 028767 46
NS 028775 46
S 028783 46
NS 028791 46
NS 028804 46
NS 028812 46
NS 028820 46
S 087070 58
NS 087089 58
S 087097 58
NS 087100 58
S 087118 58
S 087126 58
NS 087134 58
NS 087142 58
NS 085913 94
NS 085921 94
NS 085930 94
NS 085948 94
NS 085956 94
NS 085964 94
NS 085972 94
NS 085980 94
CVEP-90-83-00-00
NS
087249
112
CVEP-90-21-00-00
NS
087257
112
CVEP-90-23-00-00
NS
087265
112
CVEP-90-71-00-00
NS
087273
112
CVEP-90-41-00-00
NS
087281
112
CVEP-90-43-00-00
NS
087290
112
CVEP-90-61-00-00
NS
087302
112
CVEP-18-11-00-42
S
028839
59
CVEP-18-81-00-42
S
028847
59
CVEP-18-21-00-42
NS
028855
59
CVEP-18-71-00-42
NS
028863
59
CVEP-18-41-32-42'
NS
028871
69
CVEP-36-81-00-42
S
028644
60
CVEP-36-21-00-42
S
028660
60
CVEP-36-41-32-42'
NS
028652
70
Stock Status: S = stock AS = assembly stock NS = non -stock
To Order -Specify model, PCN, M, volts, phase and quantity.
CE approved models available. Contact your Chromalox representative.
Note -
1. Includes control transformer and contactor
2. Other sizes and configurations available, contact your Local Chromalox Sales office.
Chromalox°