Loading...
HomeMy WebLinkAboutWQ0040274_Application (FTSE)_20180920Kimley>>> Horn September 6, 2018 NCDEQ: Mooresville Regional Office Sanitary Sewer Permitting 610 E. Center Ave. Mooresville, North Carolina 28115 RECEIVED/NCDENR/DWR SEP 7 2018 V✓QROS MOORESVILLE REGIONAL OFFICE RE: Project Quattro - Fast Track Sewer System Extension Application To whom it may concern, The referenced project, "Project Quattro," is an approximately 95 -acre commercial development located between 1-85, 1-485, Wilkinson Boulevard, and Tuckaseegee Road in Charlotte, North Carolina. The development consists of a 2.4 million square foot warehouse building and associated parking and utilities. The development will be served by a combination of a new public and private sewer that will tie into an existing Charlotte Water 8" sewer main located south of the property in Wilkinson Boulevard. The following documents are enclosed: • Application (original and copy) • Application Fee ($480 check) • Flow Tracking/Acceptance Form (Charlotte Water) • Site Maps (Aerial and Topographic) Please do not hesitate to contact me by phone or by email at 704-954-7493 or matt.edwardsCabkimlev- horn.com should you need any additional information. Sincerely, ,46U-4 L�U Matt Edwards, P.E. Kimley-Horn 1200 South Tryon Street, Suite 200, Charlotte, NC 28202 State of North Carolina P_3kmwa� Department Environmental Quality Divisis ion of Water Resources 15A NCAC 02T.0300—FAST TRACK SEWER SYSTEM EXTENSION APPLICATION lvlslon of Water Resources FTA 04-16 & SUPPORTING DOCUMENTATION Application Number:4CV 77 (to be completed by DWR) All items must be completed or the application will be returned 1. APPLICANT INFORMATION: I. Applicant's name: Joe Scarborough, Seelried Properties, Inc. (company, municipality, HOA, utility, etc.) 2. Applicant type: ❑ Individual ® Corporation ❑ General Partnership ❑ Privately -Owned Public Utility ❑ Federal ❑ State/County ❑ Municipal ❑ Other 3. Signature authority's name: Joseph Scarborough per 15A NCAC 02T .0106(b) RECEIVEDINCDENRIDWR Title: Senior Development Manager SEP 7 2018 4. Applicant's mailing address: 3333 Riverwood Parkway, Suite 200 City: Atlanta State: GA Zip: 30339-_ WQROS 5. Applicant's contact information: MOORESVILLE REGIONAL OFFICE Phone number: (864) 612-8104 Email Address: JoeSgseefriedproperties.com II. PROJECT INFORMATION: I. Project name: Project Quattro 2. Application/Project status: ® Proposed (New Permit) ❑ Existing Permit/Project If a modification, provide the existing permit number: WQ00 and issued date: If new construction but part of a master plan, provide the existing permit number: W000 3. County where project is located: Mecklenburg 4. Approximate Coordinates (Decimal Degrees): Latitude: 35.245°Longitude: -80.965° 5. Parcel ID (if applicable): 05537123 (or Parcel ID to closest downstream sewer) III. CONSULTANT INFORMATION: L Professional Engineer: Matt Edwards License Number: 032640 Firm: Kimlev-Horn Mailing address: 200 South Tryon Street, Suite 200 City: Charlotte State: NC Zip: 28202 - Phone number: (704) 954-7493 Email Address: Matt.EdwardS�kimley-horn.com IV. WASTEWATER TREATMENT FACILITY (WWTF) INFORMATION: 1. Facility Name: Irwin/Sugar/McAlpine Permit Number: NC0024945, NC0024937, NCO024970 Owner Name: Charlotte Water V. RECEIVING DOWNSTREAM SEWER INFORMATION (if different than WWTF): 1. Permit Number(s): W00020120 Downstream (Receiving) Sewer Size: 8 inch System Wide Collection System Permit Number(s) (if applicable): WQCS Owner Name(s): Charlotte Water FORM: FTA 04-16 Page 1 of 5 Vl. GENERAL REQUIREMENTS 1. If the Applicant is a Privately -Owned Public Utility, has a Certificate of Public Convenience and Necessity been attached? ❑ Yes []No ®N/A 2. If the Applicant is a Developer of lots to be sold, has a Developer's Operational Agreement (FORM: DEV) been attached? ❑ Yes ❑No ®N/A 3. If the Applicant is a Home/Pro ep_rty Owners' Association, has an Operational Agreement (FORM: HOA) been attached? ❑ Yes ❑No ®N/A 4. Origin of wastewater: (check all that apply): ❑ Residential Owned ❑ Retail (stores, centers, malls) ❑ Car Wash ❑ Residential Leased ❑ Retail with food preparation/service ❑ Hotel and/or Motels ❑ School / preschool / day care ❑ Medical / dental / veterinary facilities ❑ Swimming Pool /Clubhouse ❑ Food and drink facilities ❑ Church ❑ Swimming Pool/Filter Backwash ® Businesses / offices / factories ❑ Nursing Home ❑ Other (Explain in Attachment) 5. Nature of wastewater: % Domestic/Conunercial 100 % Commercial % Industrial (See 15A NCAC 02T.0103(20)) " Is there a Pretreatment Program in effect? ❑ Yes ❑ No 6. Hasa flow reduction been approved under 15A NCAC 02T .01 l4(fl? ❑ Yes ® No ➢ If yes, provide a copy of flow reduction approval letter 7. Summarize wastewater generated by project: �y 0),V` B �o l ` � Establishment Type (see 021.0114(fl) Daily Design Flow No. of Unit Flow General business and office facilities 25 gal/day 1500 J 37,500 GPD Warehouse 100 gal/day 112 11,200 GPD gal/ GPD gal/ GPD gal/ GPD gal/ GPD Total 48,700 GPD a See 15A NCAC 02T .0114(b). (d). (e)(1) and (e)(2) for caveats to wastewater design flow rates (i.e., minimum flow per dwelling; proposed unknown non-residential development uses; public access facilities located near high public use areas; and residential property located south or east of the Atlantic Intracoastal Waterway to be used as vacation rentals as defined in G.S. 42A-4). b Per 15A NCAC 02T .0114(c), design flow rates for establishments not identified [in table 15A NCAC 02T.0114] shall be determined using available flow data, water using fixtures, occupancy or operation patterns, and other measured data. 8. Wastewater generated by project: 48700 GPD (per 15A NCAC 02T.01 14) ➢ Do not include future flows or previously permitted allocations If permitted flow is zero, indicate why: ❑ Pump Station or Gravity Sewer where flow will be permitted in subsequent permits that connect to this line ❑ Flow has already been allocated in Permit Number: ❑ Rehabilitation or replacement of existing sewer with no new flow expected ❑ Other (Explain): FORM: FTA 04-16 Page 2 of 5 VII. GRAVITY SEWER DESIGN CRITERIA (If Applicable) - 02T.0305 .','r MDC (Gravity Sewers): I. Summarize gravity sewer to be permitted: Size (inches) Length (feet) Material 6" 960 PVC 8" 1910 PVC ➢ Section II & III of the MDC for Permitting of Gravity Sewers contains infonnation related to design criteria ➢ Section III contains information related to minimum slopes for gravity sewer(s) ➢ Oversizing lines to meet minimum slope requirement is not allowed and a violation of the MDC VIII. PUMP STATION DESIGN CRITERIA (If Applicable) — 02T .0305 & MDC (Pump Stations/Force Mains): COMPLETE FOR EACH PUMP STATION INCLUDED IN THIS PROJECT 1. Pump station number or name: 2. Approximate Coordinates (Decimal Degrees): Latitude: Longitude: 3. Design flow of the pump station: millions gallons per day (firm capacity) 4. Operational point(s) of the pump(s): gallons per minute at feet total dynamic head (TDH) 5. Summarize the force main to be permitted (for this Pump Station): Size (inches) I Length (feet) Material 6. Power reliability in accordance with 15A NCAC 02T .0305(h)(1): ❑ Standby power source or pump with automatic activation and telemetry - 15A NCAC 02T .0305(h)(1)(B). ➢ Required for all pump stations with an average daily flow greater than or equal to 15,000 gallons per day ➢ Must be permanent to facility Or if the pump station has an average daily flow less than 15,000 gallons per day: ❑ Portable power source with manual activation, quick -connection receptacle and telemetry - 15A NCAC 02T .0305(h)(1)(C) or ❑ Portable pumping unit with plugged emergency pump connection and telemetry - 15A NCAC 02T .0305(h)(1)(C): ➢ It shall be demonstrated to the Division that the portable source is owned or contracted by the applicant (draft agreement) and is compatible with the station. ➢ If the portable power source or pump is dedicated to multiple pump stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump, including travel timeframes, shall be provided in the case of a multiple station power outage. FORM: FTA 04-16 Page 3 of 5 IX. SETBACKS & SEPARATIONS — (02B.0200 & ISA NCAC 02T.0305(0): 1. Does the project comply with all separations found in 15A NCAC 02T.0305(f) & (g) ® Yes ❑ No ➢ 15A NCAC 02T.0305( contains minimmn se arations that shall be rovided for sewers stems: Setback Parameter* Separation Required _ Storm sewers and other utilities not listed below (vertical) 24 inches _ Water mains (vertical -water over sewer including in benched trenches) 18 inches Water mains (horizontal) 10 feet Reclaimed water lines (vertical - reclaimed over sewer) 18 niches Reclaimed water lines horizontal - reclaimed over sewer) 2 feet **Any private or public water supply source, including any wells, WS -I waters of Class I or Class I1 impounded reservoirs used as a source of drinkin water 100 feet **Waters classified WS (except WS -I or WS -V), B, SA, ORW, HQW, or SB from normal high water or tide elevation) and wetlands see item IX.2 50 feet "Any other stream, lake, impoundment, or ground water lowering and surface drainage ditches 10 feet Any building foundation 5 feet Any basement 10 feet TOP sloe of embankment or cuts of 2 feet or more vertical height 10 feet Drainage systems and interceptor drains 5 feet Any swimming pools 10 feet Final earth grade (vertical) 36 inches ➢ 15A NCAC 02T.0305(g) contains alternatives where separations in 02T.0305(f) cannot be achieved. ➢ **Stream classifications can be identified using the Division's NC Surface Water Classifications webnaee ➢ If noncompliance with 02T.0305(f) or W. see Section X of this application 2. Does the project comply with separation requirements for wetlands? (50 feet of separation) ❑ Yes ❑ No ® N/A ➢ See the Division's draft separation requirements for situations where separation cannot be meet ➢ No variance is required if the alternative design criteria specified is utilized in design and construction ➢ As built documents should reference the location of areas effected 3. Does the project comply with setbacks found in the river basin rules per 15A NCAC 02B.0200? ❑ Yes ❑ No ® N/A ➢ This would include Trout Buffered Streams per 15A NCAC 2B.0202 4. Does the project require coverage/authorization under a 404 Nationwide or ® Yes ❑ No individual permits or 401 Water Quality Certifications? ➢ Information can be obtained from the 401 & Buffer Permitting Branch 5. Does project comply with 15A NCAC 02T.0105(c)(6) (additional permits/certifications)? ® Yes ❑ No Per 15A NCAC 02T.0105(c)(6), directly related environmental permits or certification applications are being prepared, have been applied for, or have been obtained. Issuance of this permit is contingent on issuance of dependent permits (erosion and sedimentation control plans, stormwater management plans, etc.). 6. Does this project include any sewer collection lines that are deemed "high-priority?" Per 15A NCAC 02T.0402, "high-priority sewer" means "any aerial sewer, sewer contacting surface waters, siphon, or sewer positioned parallel to streambanks that is subject to erosion that undermines or deteriorates the sewer. ❑ Yes ®No ❑ N/A ➢ If yes, include an attachment with details for each line, including type (aerial line, size, material, and location). High priority lines shall be inspected by the permittee or its representative at least once every six -months and inspections documented per 15A NCAC 02T.0403(a)(5) or the permitee's individual System -Wide Collection permit. FORM: FTA 04-16 Page 4 of 5 X. CERTIFICATIONS: 1. Does the submitted system comply with I SA NCAC 02T, the Minimum Design Criteria for the Permitting of PumpStatio m and Force Mains. (latest version), and the Gravity Sewer Minimum Design Criteria (latest versioal as applicable? ® Yes ❑ No If No, complete and submit the Variance/Alternative Design Request application (VADC 10-14) and supporting documents for review. Approval of the request is reouired Prior to submittal of the Fast Track Application and supportine documents 2. Professional Engipeer's Certification: name from Application Item Ill. L) that this application for has been reviewed by me and is accurate, complete and consistent with the information supplied in the plans, specifications, engineering calculations, and all other supporting documentation to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers (latest version), and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains (latest version). Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. NOTE — In accordance with General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000, as well as civil penalties up to $25,000 per violation. North Carolina Professional Engineer's seal, signature, and date: 3. Applicant's Certification per 15ANCAC 02T.0106(b): name r& application for has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. I understand that any discharge of wastewater from this non - discharge system to surface waters or the land will result in an immediate enforcement action that may include civil penalties, injunctive relief, and/or criminal prosecution. I will make no claim against the Division of Water Resources should a condition of this permit be violated. 1 also understand that if all required parts of this application package are not completed and that if all required supporting information and attachments are not included, this application package will be returned to me as incomplete. NOTE — In accordance with General Statutes 143-215.6A and 143-215.613 any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. Signature: / /„/s-- '!f��' Date: ql4 )b FORM: FIA 04-I6 Page 5 of 5 i Division of Water Resources State of North Carolina Department of Environmental Quality Division of Fater Resources Flow Tracking/Acceptance for Suver Extension Applications (FTSE 04-16) Entity Requesting Allocation: Kimley-Horn and Associates, Inc. Project Name for which flow is being requested: Quattro Wore than one P I SE may be required for a .Tingle project if the owner of the WH71' is not responsible for all puna) stations along the route of the proposed wastewater .flow. 1. Complete this section only if you are the owner of the wastewater treatment plant. a. WWTP Facility Name: Irwin/Sugar/McAlpine b. WWTP Facility Permit #: Nco024945, N00024937, NCO024970 A11 flows rine in MGD c. WWTP facility's permitted flow 890 d. Estimated obligated flow not yet tributary to the WWTP 11.895 e. WWTP facility's actual avg. flow 63767 f Total flow for this specific request 0.0487 g. Total actual and obligated flows to the facility 75661 h. Percent of permitted flow used 76.4 Complete this section for each pump station you are responsible for along the route of this proposed wastewater flow. List pump stations located between the project connection point and the WWTP: Paw Creek 10.5 4.20 (B) (A) (D)=(B+C) Design Pump Average Daily Station Firm Flow"* (Name or Capacity, " (Firm / pf), Number) MGD MGD Paw Creek 10.5 4.20 (B) (C) (D)=(B+C) (E)=(A-D) Obligated, Approx. Not Yet Total Current Current Avg. Tributary Flow Plus Daily Flow, Daily Flow, Obligated Available MGD MGD Flow Capacity*** 4.69 0.564 5.254 -1.054 * The Firm Capacity of any pump station is defined as the maximum pumped flow that can be achieved with the largest pump taken out of service. ** Design Average Daily Flow is the firm capacity of the pump station divided by a peaking factor (pf) not less than 2.5. *** A Planning Assessment Addendum shall be attached for each pump station located between the project connection point and the WWTP where the Available Capacity is < 0. Downstream Facility Name (Sewer): Long Creek Pumping Station Downstream Permit Number: WQ0020120 Page 1 of 6 FTSE 04-16 III. Certification Statement: 1 Keri C,antreII certify to the best of my knowledge that the addition of the volume of wastewater to be permitted in this project has been evaluated along the route to the receiving wastewater treatment facility and that the flow from this project is not anticipated to cause any capacity related sanitary sewer overflows or overburden any downstream pump station en route to the receiving treatment plant under normal circumstances, given the implementation of the planned improvements identified in the planning assessment where applicable. This analysis has been performed in accordance with local established policies and procedures using the best available data. This certification applies to those items listed above in Sections I and II plus all attached planning assessment addenclums for which I aro the responsible party. Signature of this form indicates acceptance of this wastewater flow. Signing Official Signature KA., Qom. --rte 9/5/2018 Page 2 of 6 FTSE 04-16 PLANNING ASSESSMENT ADDENDUM (PAA) Submit a planning assessment addendum for each pump station listed in Section 11 where Available Capacity is < 0. Pump Station (Name or Number): Given that: a. The proportion and amount of Obligated, Not Yet Tributary Daily Flow (C) accounts for 10.7 % and 0.564 MGD of the Available Capacity (E) in Pump Station Paw Creek ; and that b. The rate of activation of this obligated, not yet tributary capacity is currently approximately 0664 MGD per year; and that c. A funded Capital Project that will provide the required planned capacity, namely Paw Creek Force Main Replacement is in design or under Construction With planned completion in Paw creek FM -m-2021 ; and/or d. The following applies: Charlotte Waters Community Investment Plan has allocated funds for improvements to the Paw Creek force main and a five -million gallon EO basin at Long Creek Pump alalion. Long Creek and Paw Creek pump stationsoperste as a system using SCADAdats redetermine the rate offlowdryiversd from the upstream pump station, Long Creek, to Paw Creek the downstream facility. Long Creek pump station has the ability to transfer flows to flow equalization tanks during peak flow events and then meter outflow to Paw Creek as flow condilionsallow. In addition, the basins for both stations are large and result in a daily peaking factor of 2.06 at Paw Creek Pump Station, which allows the stations to operate safely at flaws greater than 40% of the firm pumping capacity. Therefore: Given reasonably expected conditions and planning information, there is sufficient justification to allow this flow to be permitted, without a significant likelihood of over -allocating capacity in the system infrastructure. I understand that this does not relieve the collection system owner from complying with G.S. 143-215.67(a) which prohibits the introduction of any waste in excess of the capacity of the waste disposal system. Signing Official Signature 1'A,. aria' Page 3 of 6 915(2018 Date FTSE 04-16 CHARLOTTE W()T E R February 27, 2018 Ms. McKenzie Publicover Kimley-Horn 200 South Tryon St Suite 200 Charlotte, NC 28202 SUBJECT: WILLINGNESS TO SERVE PROJECT QUATTRO TODD ROAD, CHARLOTTE NC RECEIVEDrNCDENR/DWR SEP 19 i(118 MOORESVILLE OROS REGIONAL OFFICE After an analysis of the sanitary sewer system associated with the proposed project, Project Quattro, it was determined that there is sufficient capacity to accommodate the proposed sewer flows from this project at the connection point(s) indicated on the submitted exhibit plan for transmission to the McAlpine Creek Wastewater Treatment Plant (NPDES Permit# NCO024970). Please note that the availability of flow is subject to change, and that this willingness to serve review in no way guarantees future capacity. Further review of the project through the Charlotte Water Capacity Assurance Program is required prior to acceptance of the proposed flows. Charlotte Water (CLTWater) agrees to furnish water to the subject project. The water quality to the subject project is regulated by the State Drinking Water Act Amendments of 1986 and The Water Supply Management Plan, PWS ID # 0160010 on file with the Public Water Supply Section of NCDEQ. However, CLTWater cannot guarantee a constant pressure or quality of flow. Due to the involvement of other agencies and continuing growth of the water and sewer system, the ability to provide service for future projects cannot be guaranteed nor reserved. Connection to the CLTWater and sewer system is accepted on a first come first served basis. The applicant should understand that this letter is not an authorization to construct or extend private water or sewer systems, as the appropriate local or State permits are required prior to construction. If you have any questions, please do not hesitate to contact me at (704) 432-5801. Barbara Gross Engineering Assistant Charlotte Water 5100 Brookshire Blvd, Charlotte, NC 28216 charlottewater.org qb Operated by the City of Charlotte MCEIVED/NCDENR/DWR SEP 19 2018 WORDS MOORESVILLE REGIONAL OFFICE Capacity Assurance Program Application Flow Analysis ID: 10018572 Customer Name: Matt Edwards, Kimley- Service City: Horn and Associates, Service State: Inc. Submittal Date: 7/19/2018 Reviewer: Jon Beam Project Name: Quattro Service Address: 8300 Tuckaseegee Rd Service City: Charlotte Service State: NC Service ZIP: 28214 Tax Parcel Number: 05537123 Approval Type: Conditional Flow Tracking Status: Inactive - Condition Connection Type: Major Certification Date: 7/26/2018 Project Type:: Non Exempt Basin:: PAW Requested Average Daily Flow (gpd): 48,700 Peaking Factor: 2.5 Percent of Flow Applied: 100 Surcharges or Downstream SSO's: No Nodes and Flows Affected by this Application (Values shown for Flow/capacity are in gallons per day) Node Name Re uested Flow Baseline CaPaGity Available Capacity Remainin Ca aci Percent Remaining 28 121,750 16,000,000 -145,816 -267,566 183.5 35+36 121,750 2,800,000 2,800,000 2,678,250 95.7 8 121,750 30,000,000 -2,500,625 -2,622,375 104.9 9 121,750 27,500,000 -4,826,115 -4,947,865 102.5 McAlpine Creek 54,544 9,400,000 4,440,381 4,385,837 98.8 PAW CREEK 121,750 -121,750 I Requested peak Flow and available capacities for pumping stations and flow monitors are reported as peak flow. Requested peak flow and available capacities for WWiPs are reported as maximum month flow. The available capacities presented for WW --Ps are approximate and for informational purposes only; consult Technical Memorandum 15 — Guidelines for Evaluating Treatment Capacity for more information. Comments: After an analysis of the sanitary sewer system associated with proposed design of project 10018572, Quattro, it was determined that there is currently sufficient capacity to accommodate the proposed average daily flow of 48,700 gallons per day at the connection point(s) indicated on the submitted utility plan. 6/25/2018 North Carolina Secretary of State Search Resu is File an Annual Report/Amend an Annual Report - Upload a PDF Filing • Order a Document Online Add Entity to My Email Notification List ^ View Filings • Print an Amended a Annual Report form Business Corporation Legal Name Seefried Industrial Properties, Inc. Information Sosld: 1715973 Status: Current -Active Annual Report Status: Current Citizenship: Foreign Date Formed: 6/14/2018 State of Incorporation: Registered Agent: COGENCY GLOBAL INC. Addresses Reg Office 212 South Tryon Street Suite 1000 Charlotte, NC 28281 Reg Mailing 212 South Tryon Street Suite 1000 Charlotte, NC 28281 Mailing Principal Office 3333 Riverwood Pkwy SE Ste 200 3333 Riverwood Pkwy SE Ste 200 Atlanta, GA 30339 Officers Stock Atlanta, GA 30339 https:// ✓ .sosnc.gov/online_services/Search/Business_Registration_profile?Id=14330417 1/1 Central Files: APS _ SWP _ 9/20/2018 Permit Number WQ0040274 Program Category Non -discharge Permit Type Gravity Sewer Extension, Pump Stations, & Pressure Sewer Extensions Primary Reviewer barry.love Coastal SWRuIe Permitted Flow 48,700 Facility Permit Tracking Slip Status Project Type Active New Project Version Permit Classification 1.00 Individual Permit Contact Affiliation Facility Name Major/Minor Region Project Quattro Minor Mooresville Location Address County Mecklenburg Facility Contact Affiliation Owner Owner Name Owner Type Seefried Properties Inc Non -Government Owner Affiliation Joseph Scarborough 3333 Riverwood Pkwy Dates/Events Atlanta GA 30339 Scheduled Orig Issue App Received Draft Initiated Issuance Public Notice Issue Effective Expiration 9/20/2018 9/7/2018 9/20/2018 9/20/2018 Regulated Activities Requested /Received Events Office Additional information requested Wastewater collection Additional information received Outfall Waterbody Name Streamindex Number Current Class Subbasin