HomeMy WebLinkAboutNC0073393_NOD-2018-PC-0281_20180830 North Carolina Department of Environmental Quality | Division of Water Resources 2090 U.S. 70 Highway, Swannanoa, NC 28778 828-296-4500 August 29, 2018 Vito Montaperto Dana-Hill Corporation 1010 Dana Rd Hendersonville, NC 28792 SUBJECT: NOTICE OF DEFICIENCY Tracking Number: NOD-2018-PC-0281 Permit No. NC0073393 Dana Hill WWTP Henderson County Dear Permittee: The North Carolina Division of Water Resources conducted an inspection of the Dana Hill WWTP on August 29, 2018. This inspection was conducted to verify that the facility is operating in compliance with the conditions and limitations specified in NPDES WW Permit No. NC0073393. A summary of the findings and comments noted during the inspection are provided in the enclosed copy of the inspection report. The Compliance Evaluation inspection was conducted by Division of Water Resources staff from the Asheville Regional Office. The following deficiencies were noted during the inspection: Inspection Area Description of Deficiency _________________________________________________________________________________________________________________________________________________________________________ Effluent Sampling Composite sampling is currently time based, but must be flow proportional. _________________________________________________________________________________________________________________________________________________________________________ Flow Measurement - Effluent Mrs. James said that the meter had been calibrated last year, but there was no documentation of that calibration event. The meter readout was having issues during the inspection. The LCD display was flashing through different screens and seemed to be displaying glitches. _________________________________________________________________________________________________________________________________________________________________________ DocuSign Envelope ID: C36D71F6-1AF5-469E-8140-3943F1F09BBF North Carolina Department of Environmental Quality | Division of Water Resources 2090 U.S. 70 Highway, Swannanoa, NC 28778 828-296-4500 Inspection Area Description of Deficiency _________________________________________________________________________________________________________________________________________________________________________ Aeration Basins The blowers for the aeration basins did not have the guards covering the belts and pulleys. The uncovered belts and pulleys are a safety hazard and need to be addressed. _________________________________________________________________________________________________________________________________________________________________________ In addition, the issues below must also be addressed: Compliance Issue(s): One of the secondary clarifiers had a lot of pin floc and floating sludge. Ms. Hunter said that the skimmer could not run for long without causing sludge to rise in that clarifier. Remedial actions should have already been taken to correct this problem and prevent further occurrences in the future. The Division of Water Resources may pursue enforcement action for this and any additional violations of State law. To prevent further action, carefully review these deficiencies and address the causes of non-compliance to prevent the recurrence of similar situations. If you should have any questions, please do not hesitate to contact Daniel Boss with the Water Quality Regional Operations Section in the Asheville Regional Office at 828-296-4500. Sincerely, G. Landon Davidson, P.G., Regional Supervisor Water Quality Regional Operations Section Asheville Regional Office Division of Water Resources, NCDEQ ATTACHMENTS Ec: WQS ARO Server Laserfiche James & James Environmental 20180829_NC0073393_NOD2018PC0281.rtf DocuSign Envelope ID: C36D71F6-1AF5-469E-8140-3943F1F09BBF