HomeMy WebLinkAboutSW3171201_Design Calculations_20180827STORMWATER BMP CALCULATIONS
VILLAGE AT GRANITE QUARRY - PHASE 1
Granite Quarry, Rowan County, North Carolina
Prepared for:
LGI HOMES
Contact: Jeff Webb
3037 Sherman Drive
Lancaster, SC
P. 844-566-4300
Prepared by:
DPR Associates, Inc.
420 Hawthorne Lane
Charlotte, NC 28204
P. 704-332-1204
F. 704-332-1210
www.dprassociates.net
DPR Project No.: 17031
November 27, 2017
February 26, 2018
March 30, 2018
June 25, 2018
6-25-2018
_______________________ _____________________
DPR Associates, Inc. Hy V. Nguyen, PE
DPR Associates, Inc. Michael Barefoot, PE
TABLE OF CONTENTS
I. NARRATIVE
II. BMP SUMMARY
III. BMP EXHIBITS AND CALCULATIONS
- Vicinity Map and Aerial Photo
- Pre-Development Drainage Map
- Post-Development Drainage Map
- Pre-Development TOC Map
- TOC Calculations
- Run-Off Curve Number
- Soils Map
IV. BMP DESIGN AND CALCULATIONS
V. BMP HYDROGRAGH ANALYSIS
- Hydrograph Summary Report
- Hydrograph Pond Report
- Hydrograph Report
VI. APPENDIX
I. NARRATIVE
T:\PROJECTS\2017 PROJECTS\17031 The Village At Granite - LGI\CALCS\BMP\Phase 1\17031-Ph 1 BMP
Narrative.doc Page 1 of 3
VILLAGE AT GRANITE QUARRY – PHASE 1
BMP STORMWATER DESIGN NARRATIVE
DPR No. 17031
November 20, 2017
Revised 12‐21‐17
Revised 3‐30‐18
Revised 6‐25‐18
The enclosed package shows the results of the stormwater BMP design calculations for Phase 1 of Village
at Granite subdivision. The development is in Granite Quarry, Rowan County, North Carolina, at 3040
Faith Road. The net site area is approximately +/‐108 acres and the existing conditions consist of covered
buildings with pavement, open space and woods. This project’s proposed development will be a 118 lot
single‐family residential subdivision.
Phase 1 has 5 proposed BMP facilities for the site, one wet pond, one dry detnetion and three sand filters.
All were designed per the most recent NCDENR Stormwater design manual. Topographic maps and field
observations were used to delineate the watershed basins and hydraulic path feeding into the study
conveyance system. With this information, hydraulic lengths, time of concentrations (TOC), and basin
slopes were determined for the pre‐developed conditions. TOC of 5 minutes was used for all post‐
developed conditions. The total impervious areas of the development were calculated. The composite
curve numbers (CN) were calculated based on the hydrologic soil types and groups from the U.S.
Department of Agriculture, SCS method for the pre‐developed and post‐developed conditions.
Surface areas of BMPs 1‐4 were sized to handle the first‐inch of rainfall based on total impervious area of
the watershed. The BMP facilities are designed to treat the 1st‐Inch of rainfall water quality volume using
the Schueler simple method and to provide for channel protection using the 1‐year, 24‐hr storm.
Modeling results indicate that 2‐year and 10‐year (24‐hr storm events, using SCS Method) release peak
flow rates for the post‐development detention routed conditions are less than that of pre‐developed
conditions.
The proposed dry detention pond near Faith Road, BMP #6 is designed for detention purposes only. We
have made the commitment that the future multi‐family and future commercial developments will treat
the water quality/detention during that permit process.
Refer to the detailed maps, calculations, results, and details as shown in this package and in the civil
engineering subdivision plans.
T:\PROJECTS\2017 PROJECTS\17031 The Village At Granite - LGI\CALCS\BMP\Phase 1\17031-Ph 1 BMP
Narrative.doc Page 2 of 2
Table 1: DRAINAGE AREAS:
Basin No.
Drainage Area
Pre‐Developed
(+/‐ Ac.)
Drainage Area
Post‐Developed
(+/‐ Ac.)
Phase 1 BMP #1 5.5 5.0
Phase 1 BMP #2 9.5 9.0
Phase 1 BMP #3 16.0 22.0
Phase 1 BMP #4 5.0 4.0
Phase 1 Temp. BMP #5 2.5 ‐‐‐‐‐
Phase 1 BMP #6 5.5 6
Phase 1 Undetained Areas*4.3 5.0
TABLE 2: PRE‐DEVELOPED DISCHARGES:
1 ‐Year 2 ‐Year (cfs)10 ‐ Year (cfs)
Phase 1 BMP #1 1.670 3.289 8.897
Phase 1 BMP #2 7.971 12.240 25.190
Phase 1 BMP #3 8.685 14.040 30.470
Phase 1 BMP #4 1.415 3.036 8.691
Phase 1 Temp. BMP #5 2.098 3.221 6.628
Phase 1 BMP #6 3.112 5.599 13.530
Phase 1 Undetained Areas* 1.675 3.607 10.010
TABLE 3: POST‐DEVELOPED DISCHARGES:
1 ‐Year 2 ‐Year (cfs)10 ‐ Year (cfs)
Phase 1 BMP #1 11.410 15.410 26.390
Phase 1 BMP #2 22.590 29.950 49.890
Phase 1 BMP #3 50.190 67.800 116.130
Phase 1 BMP #4 7.892 10.870 19.460
Phase 1 BMP #6 7.398 11.200 22.510
Phase 1 Undetained Areas* 5.743 8.836 18.110
TABLE 4: ROUTED‐DEVELOPED DISCHARGES:
1 ‐Year 2 ‐Year (cfs)10 ‐ Year (cfs)
Phase 1 BMP #1 0.204 0.278 6.437
Phase 1 BMP #2 0.255 0.503 15.770
Phase 1 BMP #3 0.411 1.514 28.610
Phase 1 BMP #4 0.163 0.241 6.751
Phase 1 BMP #6 0.256 0.910 10.200
Phase 1 Undetained Areas* 5.743 8.836 18.110
*Undetained areas include areas that are disturbed during construction but covered with grass in
the final condition (5.0ac) and BUA (0.30ac)
III. BMP EXHIBITS AND CALCULATIONS
- Vicinity Map and Arial Photo
- Pre-Development Drainage Map
- Post-Development Drainage Map
- Pre-Development TOC Map
- TOC Calculations
- Run-Off Curve Number
- Impervious Calculation
- Soils Map
Project: Village at Granite
DPR Job #: 17031
Location: Granite Quarry, NC
Impervious Calculation
Phase 1
Prepared by: RJ
Checked by: HVN
Date:
Estimated Impervious Area Breakdown for Phase 1 BMP 1
Proposed 50' Wide Single Family Lots
3,210 sf x 9 lots…………………………..…………………..………………………………28,890 sq ft =0.66 ac
(avg house pad 40' x 60' + 18' x 20lf Driveway
+ 5' x 20' sidewalk + 150 sf Patio + 200 sf Future Allocated BUA)
Proposed 60' Wide Single Family Lots
3,210 sf x 9 lots………………………………………………..……………………………28,890 sq ft =0.66 ac
(avg house pad 40' x 60' + 18' x 20lf Driveway
+ 5' x 20' sidewalk + 150 sf Patio + 200 sf Future Allocated BUA)
Proposed 70' Wide Single Family Lots
4,060 sf x 1.75 lots……………………………………….……..……………………………7,105 sq ft =0.16 ac
(avg house pad 50' x 65' + 18' x 20lf Driveway
+ 5' x 20' sidewalk + 150 sf Patio + 200 sf Future Allocated BUA)
Total Proposed Lots:64,885 sq ft =1.49 ac
Proposed Streets:
Winding Creek Road, B/C-B/C (approx. 26' x 770 lf)…………………………………20,020 sq ft =0.46 ac
Sidewalk (approx. 5' x 770lf x 2)………………………….……………………….7,700 sq ft =0.18 ac
Driveway within R/W (20 x 6' x 18 lf)……………………………………………………2,160 sq ft =0.05 ac
Emergency Fire Access (20' x 100 lf)……………………………………………………2,000 sq ft =0.05 ac
Total Proposed Streets:31,880 sq ft =0.73 ac
Total Impervious Area…………………………………………………………………….96,765 sq ft = 2.22 ac
Total Net Site Area = …………………………………………….…………………………………………………..107.90 ac
Phase 1 Site Area = …………………………………………….…………………………………………………..41.54 ac
BMP 1 Watershed Area = ………………..…………..………………………………………………………………..5.00 ac
Impervious Area Summary
Imperv. Area % of Imp. Area of % of Imp. Area of % of Imp. Area of
(Ac) Site Area Phase 1 Site Area BMP 1 WS Area
Proprosed Lots 1.49 1.38%3.59%29.79%
Prop. Amenity Area +
Misc. Site Features 0.00 0.00%0.00%0.00%
Proposed Streets 0.73 0.68% 1.76% 14.64%
Future Muilti-Famly 0.00 0.00% 0.00% 0.00%
Total Imp. Area 2.22 2.06%5.35%44.43%
USED 48% IN
DESIGN
T:\PROJECTS\2017 PROJECTS\17031 The Village At Granite - LGI\CALCS\BMP\Phase 1\17031-PH1-Impervious.xlsplotted: 2/27/2018 Sheet 1 of 1
Project: Village at Granite
DPR Job #: 17031
Location: Granite Quarry, NC
Impervious Calculation
Phase 1
Prepared by: RJ
Checked by: HVN
Date:
Estimated Impervious Area Breakdown for Phase 1 BMP 2
Proposed 50' Wide Single Family Lots
3,210 sf x 6 lots…………………………………..………………………………..19,260 sq ft =0.44 ac
(avg house pad 40' x 60' + 18' x 20lf Driveway
+ 5' x 20' sidewalk + 150 sf Patio + 200 sf Future Allocated BUA)
Proposed 60' Wide Single Family Lots
3,210 sf x 0.25 lots…………………………………..………………………………..0,803 sq ft =0.02 ac
(avg house pad 40' x 60' + 18' x 20lf Driveway
+ 5' x 20' sidewalk + 150 sf Patio + 200 sf Future Allocated BUA)
Proposed 70' Wide Single Family Lots
4,060 sf x 20.5 lots…………………………………..………………………………..83,230 sq ft =1.91 ac
(avg house pad 50' x 65' + 18' x 20lf Driveway
+ 5' x 20' sidewalk + 150 sf Patio + 200 sf Future Allocated BUA)
Total Proposed Lots:103,293 sq ft =2.37 ac
Proposed Streets:
Winding Creek Road, B/C-B/C (approx. 26' x 772 lf)…………………………………20,072 sq ft =0.46 ac
Village Commons Drive, B/C-B/C (approx. 26' x 488 lf)………………………………12,688 sq ft =0.29 ac
Sidewalk (approx. 5' x 1,260 lf x 2)………………………….……………………….12,600 sq ft =0.29 ac
Driveway within R/W (23 x 6' x 18 lf)……………………………………………………2,484 sq ft =0.06 ac
Emergency Fire Access (20' x 260 lf)……………………………………………………5,200 sq ft =0.12 ac
Total Proposed Streets:53,044 sq ft =1.22 ac
Total Impervious Area…………………………………………………………………….156,337 sq ft = 3.59 ac
Total Net Site Area=…………………………………………….…………………………………………………..107.90 ac
Phase 1 Site Area = …………………………………………….…………………………………………………..41.54 ac
BMP 2 Watershed Area = ………………..…………..………………………………………………………………..8.50 ac
Impervious Area Summary
Imperv. Area % of Imp. Area of % of Imp. Area of % of Imp. Area of
(Ac) Site Area Phase 1 Site Area BMP 2 WS Area
Proprosed Lots 2.37 2.20%5.71%27.90%
Prop. Amenity Area +
Misc. Site Features 0.00 0.00%0.00%0.00%
Proposed Streets 1.22 1.13% 2.93% 14.33%
Future Muilti-Famly 0.00 0.00% 0.00% 0.00%
Total Imp. Area 3.59 3.33%8.64%42.22%
USED 48% IN
DESIGN
T:\PROJECTS\2017 PROJECTS\17031 The Village At Granite - LGI\CALCS\BMP\Phase 1\17031-PH1-Impervious.xlsplotted: 2/27/2018 Sheet 1 of 1
Project: Village at Granite
DPR Job #: 17031
Location: Granite Quarry, NC
Impervious Calculation
Phase 1
Prepared by: RJ
Checked by: HVN
Date:
Estimated Impervious Area Breakdown for Phase 1 BMP 3
Proposed 50' Wide Single Family Lots
3,210 sf x 19.25 lots…………………………………..………………………………..61,793 sq ft =1.42 ac
(avg house pad 40' x 60' + 18' x 20lf Driveway
+ 5' x 20' sidewalk + 150 sf Patio + 200 sf Future Allocated BUA)
Proposed 60' Wide Single Family Lots
3,210 sf x 16.75 lots…………………………………..………………………………..53,768 sq ft =1.23 ac
(avg house pad 40' x 60' + 18' x 20lf Driveway
+ 5' x 20' sidewalk + 150 sf Patio + 200 sf Future Allocated BUA)
Proposed 70' Wide Single Family Lots
4,060 sf x 22.25 lots…………………………………..………………………………..90,335 sq ft =2.07 ac
(avg house pad 50' x 65' + 18' x 20lf Driveway
+ 5' x 20' sidewalk + 150 sf Patio + 200 sf Future Allocated BUA)
Total Proposed Lots:205,895 sq ft =4.73 ac
Proposed Amenity Areas…………………..………………………………………… 10,000 sq ft =0.23 ac
Play Ground Equipment, Metal Gazebo Pavilion
Proposed Cluster Mailbox, Entry monuments, Misc ………………………………………20,000 sq ft =0.46 ac
On-Street Parking (approx. 1,015 sq ft)
Proposed Streets:
Limestone Terrace, B/C-B/C (approx. 36' x 650 lf )……………………………………23,400 sq ft =0.54 ac
Winding Creek Road, B/C-B/C (approx. 26' x 150 lf)……………………………………3,900 sq ft =0.09 ac
Village Commons Drive, B/C-B/C (approx. 26' x 940 lf)………………………………24,440 sq ft =0.56 ac
Standing Oak Drive, B/C-B/C (approx. 26' x 650 lf)………………..……………………16,900 sq ft =0.39 ac
Trailwood Court, B/C-B/C (approx. 26' x 200 lf + 4,931 sq ft)…………………………10,131 sq ft =0.23 ac
Ramses Rock Run, B/C-B/C (approx. 6,885 sq ft)………………………………………6,885 sq ft =0.16 ac
Sidewalk (approx. 5' x 3,481 lf x 2)………………………….……………………….34,810 sq ft =0.80 ac
Driveway within R/W (10 x 4' x 18 lf)………………………………………………………720 sq ft =0.02 ac
Driveway within R/W (50 x 6' x 18 lf)………………………………………………………5,832 sq ft =0.13 ac
Emergency Fire Access (20' x 225 lf)……………………………………………………4,500 sq ft =0.10 ac
Total Proposed Streets:131,518 sq ft =3.02 ac
Future Multi Family Site
BUA = 50% Inpervious of 3.5 ac……………...…………………………………………76,230 sq ft =1.75 ac
BMP 3 Premanent Water Surface Are a……………...……………………………………16,200 sq ft =0.37 ac
Total Impervious Area……………………………………………………………………..459,843 sq ft = 10.56 ac
Total Net Site Area=…………………………………………….…………………………………………………..107.90 ac
Phase 1 Site Area = …………………………………………….…………………………………………………..41.54 ac
BMP 3 Watershed Area = ………………..…………..………………………………………………………………..22.50 ac
Impervious Area Summary
Imperv. Area % of Imp. Area of % of Imp. Area of % of Imp. Area of
(Ac) Site Area Phase 1 Site Area BMP 3 WS Area
Proprosed Lots 4.73 4.38%11.38%21.01%
Prop. Amenity Area +
Misc. Site Features 0.69 0.64%1.66%3.06%
Proposed Streets 3.02 2.80%7.27%13.42%
Future Muilti-Famly 1.75 1.62%4.21%7.78%
BMP 3 PWS 0.37 0.34%0.90%1.65%
Total Imp. Area 10.56 9.78%25.41%46.92%
USED 48% IN
DESIGN
T:\PROJECTS\2017 PROJECTS\17031 The Village At Granite - LGI\CALCS\BMP\Phase 1\17031-PH1-Impervious.xlsplotted: 2/27/2018 Sheet 1 of 1
Project: Village at Granite
DPR Job #: 17031
Location: Granite Quarry, NC
Impervious Calculation
Phase 1
Prepared by: RJ
Checked by: HVN
Date:
Estimated Impervious Area Breakdown for Phase 1 BMP 4
Proposed 50' Wide Single Family Lots
3,210 sf x 7.75 lots…………………………………..………………………………..24,878 sq ft =0.57 ac
(avg house pad 40' x 60' + 18' x 20lf Driveway
+ 5' x 20' sidewalk + 150 sf Patio + 200 sf Future Allocated BUA)
Proposed 70' Wide Single Family Lots
4,060 sf x 5.5 lots…………………………………..………………………………..22,330 sq ft =0.51 ac
(avg house pad 50' x 65' + 18' x 20lf Driveway
+ 5' x 20' sidewalk + 150 sf Patio + 200 sf Future Allocated BUA)
Total Proposed Lots:47,208 sq ft =1.08 ac
Proposed Streets:
Standing Oak Drive, B/C-B/C (approx. 26' x 285 lf)………………..…………………7,410 sq ft =0.17 ac
Sidewalk (approx. 5' x 285 lf x 2)………………………….……………………….2,850 sq ft =0.07 ac
Driveway within R/W (9 x 6' x 18 lf)………………………………………………………972 sq ft =0.02 ac
Total Proposed Streets:11,232 sq ft =0.26 ac
Total Impervious Area…………………………………………………………………….58,440 sq ft = 1.34 ac
Total Net Site Area=…………………………………………….…………………………………………………..107.90 ac
Phase 1 Site Area = …………………………………………….…………………………………………………..41.54 ac
BMP 4 Watershed Area = ………………..…………..………………………………………………………………..4.00 ac
Impervious Area Summary
Imperv. Area % of Imp. Area of % of Imp. Area of % of Imp. Area of
(Ac) Site Area Phase 1 Site Area BMP 4 WS Area
Proprosed Lots 1.08 1.00%2.61%27.09%
Prop. Amenity Area +
Misc. Site Features 0.00 0.00% 0.00% 0.00%
Proposed Streets 0.26 0.24% 0.62% 6.45%
Future Muilti-Famly 0.00 0.00% 0.00% 0.00%
Total Imp. Area 1.34 1.24%3.23%33.54%
USED 48% IN
DESIGN
T:\PROJECTS\2017 PROJECTS\17031 The Village At Granite - LGI\CALCS\BMP\Phase 1\17031-PH1-Impervious.xlsplotted: 2/27/2018 Sheet 1 of 1
Project: Village at Granite
DPR Job #: 17031
Location: Granite Quarry, NC
Impervious Calculation
Phase 1
Prepared by: RJ
Checked by: HVN
Date:
Estimated Impervious Area Breakdown for Phase 1 BMP 6
Existing Streets:
Faith Road………………..……………………………………………………………..…30,492 sq ft =0.70 ac
Proposed Streets:
Faith Road, B/C-B/C………………………………..……..…………………………….11,700 sq ft =0.27 ac
Limestone Terrace, B/C-B/C …………………………………..……………..…………18,600 sq ft =0.43 ac
Sidewalk (approx. 5' x 370 lf x 2)………………………….……………………….3,700 sq ft =0.08 ac
Emergency Access #1…………………………………….…..…………………………8,000 sq ft =0.18 ac
Total Proposed Streets:42,000 sq ft =0.96 ac
Total Impervious Area…………………………………………………………………….72,492 sq ft = 1.66 ac
Total Net Site Area=…………………………………………….…………………………………………………..107.90 ac
Phase 1 Site Area = …………………………………………….…………………………………………………..41.54 ac
BMP 6 Watershed Area = ………………..…………..………………………………………………………………..5.00 ac
Impervious Area Summary
Imperv. Area % of Imp. Area of % of Imp. Area of % of Imp. Area of
(Ac) Site Area Phase 1 Site Area BMP 6 WS Area
Existing Streets 0.70 0.65% 1.69% 14.00%
Proposed Streets 0.96 0.89% 2.32% 19.28%
Total Imp. Area 1.66 1.54%4.01%33.28%
T:\PROJECTS\2017 PROJECTS\17031 The Village At Granite - LGI\CALCS\BMP\Phase 1\17031-PH1-Impervious.xlsplotted: 8/13/2018 Sheet 1 of 1
Hydrologic Soil Group—Rowan County, North Carolina
(17031-Soils)
Natural Resources
Conservation Service
Web Soil Survey
National Cooperative Soil Survey
9/21/2017
Page 1 of 43940200394030039404003940500394060039407003940800394090039402003940300394040039405003940600394070039408003940900547900548000548100548200548300548400548500
548000 548100 548200 548300 548400 548500
35° 36' 38'' N 80° 28' 16'' W35° 36' 38'' N80° 27' 52'' W35° 36' 12'' N
80° 28' 16'' W35° 36' 12'' N
80° 27' 52'' WN
Map projection: Web Mercator Corner coordinates: WGS84 Edge tics: UTM Zone 17N WGS84
0 150 300 600 900
Feet
0 50 100 200 300
Meters
Map Scale: 1:3,890 if printed on A portrait (8.5" x 11") sheet.
Soil Map may not be valid at this scale.
MAP LEGEND MAP INFORMATION
Area of Interest (AOI)
Area of Interest (AOI)
Soils
Soil Rating Polygons
A
A/D
B
B/D
C
C/D
D
Not rated or not available
Soil Rating Lines
A
A/D
B
B/D
C
C/D
D
Not rated or not available
Soil Rating Points
A
A/D
B
B/D
C
C/D
D
Not rated or not available
Water Features
Streams and Canals
Transportation
Rails
Interstate Highways
US Routes
Major Roads
Local Roads
Background
Aerial Photography
The soil surveys that comprise your AOI were mapped at
1:24,000.
Warning: Soil Map may not be valid at this scale.
Enlargement of maps beyond the scale of mapping can cause
misunderstanding of the detail of mapping and accuracy of soil
line placement. The maps do not show the small areas of
contrasting soils that could have been shown at a more detailed
scale.
Please rely on the bar scale on each map sheet for map
measurements.
Source of Map: Natural Resources Conservation Service
Web Soil Survey URL:
Coordinate System: Web Mercator (EPSG:3857)
Maps from the Web Soil Survey are based on the Web Mercator
projection, which preserves direction and shape but distorts
distance and area. A projection that preserves area, such as the
Albers equal-area conic projection, should be used if more
accurate calculations of distance or area are required.
This product is generated from the USDA-NRCS certified data as
of the version date(s) listed below.
Soil Survey Area: Rowan County, North Carolina
Survey Area Data: Version 13, Sep 20, 2016
Soil map units are labeled (as space allows) for map scales
1:50,000 or larger.
Date(s) aerial images were photographed: Jun 14, 2015—Mar
15, 2017
The orthophoto or other base map on which the soil lines were
compiled and digitized probably differs from the background
imagery displayed on these maps. As a result, some minor
shifting of map unit boundaries may be evident.
Hydrologic Soil Group—Rowan County, North Carolina
(17031-Soils)
Natural Resources
Conservation Service
Web Soil Survey
National Cooperative Soil Survey
9/21/2017
Page 2 of 4
Hydrologic Soil Group
Hydrologic Soil Group— Summary by Map Unit — Rowan County, North Carolina (NC159)
Map unit symbol Map unit name Rating Acres in AOI Percent of AOI
CcB Cecil sandy loam, 2 to 8
percent slopes
B 2.5 5.7%
CeB2 Cecil sandy clay loam, 2
to 8 percent slopes,
moderately eroded
B 10.1 23.0%
ChA Chewacla loam, 0 to 2
percent slopes,
frequently flooded
B/D 0.4 0.8%
VnB2 Vance sandy clay loam,
2 to 8 percent slopes,
moderately eroded
C 19.2 43.7%
VnC2 Vance sandy clay loam,
8 to 15 percent
slopes, moderately
eroded
C 11.8 26.8%
Totals for Area of Interest 43.9 100.0%
Hydrologic Soil Group—Rowan County, North Carolina 17031-Soils
Natural Resources
Conservation Service
Web Soil Survey
National Cooperative Soil Survey
9/21/2017
Page 3 of 4
Description
Hydrologic soil groups are based on estimates of runoff potential. Soils are
assigned to one of four groups according to the rate of water infiltration when the
soils are not protected by vegetation, are thoroughly wet, and receive
precipitation from long-duration storms.
The soils in the United States are assigned to four groups (A, B, C, and D) and
three dual classes (A/D, B/D, and C/D). The groups are defined as follows:
Group A. Soils having a high infiltration rate (low runoff potential) when
thoroughly wet. These consist mainly of deep, well drained to excessively
drained sands or gravelly sands. These soils have a high rate of water
transmission.
Group B. Soils having a moderate infiltration rate when thoroughly wet. These
consist chiefly of moderately deep or deep, moderately well drained or well
drained soils that have moderately fine texture to moderately coarse texture.
These soils have a moderate rate of water transmission.
Group C. Soils having a slow infiltration rate when thoroughly wet. These consist
chiefly of soils having a layer that impedes the downward movement of water or
soils of moderately fine texture or fine texture. These soils have a slow rate of
water transmission.
Group D. Soils having a very slow infiltration rate (high runoff potential) when
thoroughly wet. These consist chiefly of clays that have a high shrink-swell
potential, soils that have a high water table, soils that have a claypan or clay
layer at or near the surface, and soils that are shallow over nearly impervious
material. These soils have a very slow rate of water transmission.
If a soil is assigned to a dual hydrologic group (A/D, B/D, or C/D), the first letter is
for drained areas and the second is for undrained areas. Only the soils that in
their natural condition are in group D are assigned to dual classes.
Rating Options
Aggregation Method: Dominant Condition
Component Percent Cutoff: None Specified
Tie-break Rule: Higher
Hydrologic Soil Group—Rowan County, North Carolina 17031-Soils
Natural Resources
Conservation Service
Web Soil Survey
National Cooperative Soil Survey
9/21/2017
Page 4 of 4
Project: Village at GraniteDPR Job No.: 17031Location: Granite Quarry, NCDPR ASSOCIATES, INCRUN-OFF CURVE NUMBERPrepared by: RJChecked by: MBDate: 11-17-171Total Drain. Area (Ac.)5.50Site Soil TypeSoil GroupPercentage of BasinCeB2B1.0 ac18.2%VnB2, VnC2C4.0 ac72.7%5.0 ac90.9%Hydrologic Soil Group UsedLand UseNo. AcresPercent of Drainage AreaCN for Group BGroup B Weighted CN CN for Group B/DGroup B/D Weighted CN CN for Group CGroup C Weighted CN Total Weighted CN Weighted CN %Wood (Good Cond.)0.509.1%5510.0660.07050.9 60.9 5.5Open Space - Grass and Shurbs (Good Cond.)5.0090.9%6111.1710.07453.8 64.9 59.0Impervious0.000.0%9817.8980.09871.3 89.1 0.064.5Total5.5100%Composite Curve Number (CN):651Total Drain. Area (Ac.)5.00Site Soil TypeSoil GroupPercentage of BasinCeB2B1.0 ac20.0%VnB2, VnC2C4.0 ac80.0%5.0 ac100.0%Hydrologic Soil Group UsedLand UseNo. AcresPercent of Drainage AreaCN for Group BGroup B Weighted CN CN for Group B/DGroup B/D Weighted CN CN for Group CGroup C Weighted CN Total Weighted CN Weighted CN %Wood (Good Cond.)0.000.0%5511.0660.07056.0 67.0 0.0Open Space - Grass and Shurbs (Good Cond.)2.6052.0%6112.2710.07459.2 71.4 37.1Impervious2.4048.0%9819.6980.09878.4 98.0 47.084.2Total5.0100%Composite Curve Number (CN):84Existing Condition Watershed BMP #Proposed Development Watershed BMP #T:\PROJECTS\2017 PROJECTS\17031 The Village At Granite - LGI\CALCS\BMP\Phase 1\17031-PH1-Runoff CN.xlsSheet: 1 of 6 3/30/2018
Project: Village at GraniteDPR Job No.: 17031Location: Granite Quarry, NCDPR ASSOCIATES, INCRUN-OFF CURVE NUMBERPrepared by: RJChecked by: MBDate: 11-17-172Total Drain. Area (Ac.)9.50Site Soil TypeSoil GroupPercentage of BasinVnB2, VnC2C9.5 ac100.0%9.5 ac100.0%Hydrologic Soil Group UsedLand UseNo. AcresPercent of Drainage AreaCN for Group BGroup B Weighted CN CN for Group B/DGroup B/D Weighted CN CN for Group CGroup C Weighted CN Total Weighted CN Weighted CN %Wood (Good Cond.)4.0042.1%550.0660.07070.0 70.0 29.5Open Space - Grass and Shurbs (Good Cond.)5.0052.6%610.0710.07474.0 74.0 38.9Impervious0.505.3%980.0980.09898.0 98.0 5.273.6Total9.5100%Composite Curve Number (CN):742Total Drain. Area (Ac.)9.00Site Soil TypeSoil GroupPercentage of BasinVnB2, VnC2C9.0 ac100.0%9.0 ac100.0%Hydrologic Soil Group UsedLand UseNo. AcresPercent of Drainage AreaCN for Group BGroup B Weighted CN CN for Group B/DGroup B/D Weighted CN CN for Group CGroup C Weighted CN Total Weighted CN Weighted CN %Wood (Good Cond.)0.000.0%550.0660.07070.0 70.0 0.0Open Space - Grass and Shurbs (Good Cond.)4.6852.0%610.0710.07474.0 74.0 38.5Impervious4.3248.0%980.0980.09898.0 98.0 47.085.5Total9.0100%Composite Curve Number (CN):86Existing Condition Watershed BMP #Proposed Development Watershed BMP #T:\PROJECTS\2017 PROJECTS\17031 The Village At Granite - LGI\CALCS\BMP\Phase 1\17031-PH1-Runoff CN.xlsSheet: 1 of 1 6/22/2018
Project: Village at GraniteDPR Job No.: 17031Location: Granite Quarry, NCDPR ASSOCIATES, INCRUN-OFF CURVE NUMBERPrepared by: RJChecked by: MBDate: 11-17-173Total Drain. Area (Ac.)16.00Site Soil TypeSoil GroupPercentage of BasinCcB, CeB2B3.0 ac18.8%ChAB/D1.0 ac6.3%VnB2, VnC2C12.0 ac75.0%16.0 ac100.0%Hydrologic Soil Group UsedLand UseNo. AcresPercent of Drainage AreaCN for Group BGroup B Weighted CN CN for Group B/DGroup B/D Weighted CN CN for Group CGroup C Weighted CN Total Weighted CN Weighted CN %Wood (Good Cond.)1.408.8%5510.3664.17052.5 66.9 5.9Open Space - Grass and Shurbs (Good Cond.)13.4083.8%6111.4714.47455.5 71.4 59.8Impervious1.106.9%9818.4986.19873.5 98.0 6.772.4Total15.999%Composite Curve Number (CN):723Total Drain. Area (Ac.)22.00Site Soil TypeSoil GroupPercentage of BasinCcB, CeB2B3.9 ac17.7%ChAB/D0.3 ac1.4%VnB2, VnC2C17.8 ac80.9%22.0 ac100.0%Hydrologic Soil Group UsedLand UseNo. AcresPercent of Drainage AreaCN for Group BGroup B Weighted CN CN for Group B/DGroup B/D Weighted CN CN for Group CGroup C Weighted CN Total Weighted CN Weighted CN %Wood (Good Cond.)0.000.0%559.8660.97056.6 67.3 0.0Open Space - Grass and Shurbs (Good Cond.)11.4452.0%6110.8711.07459.9 71.7 37.3Impervious10.5648.0%9817.4981.39879.3 98.0 47.084.3Total22.0100%Composite Curve Number (CN):84Existing Condition Watershed BMP #Proposed Development Watershed BMP #T:\PROJECTS\2017 PROJECTS\17031 The Village At Granite - LGI\CALCS\BMP\Phase 1\17031-PH1-Runoff CN.xlsSheet: 1 of 1 6/22/2018
Project: Village at GraniteDPR Job No.: 17031Location: Granite Quarry, NCDPR ASSOCIATES, INCRUN-OFF CURVE NUMBERPrepared by: RJChecked by: MBDate: 11-17-174Total Drain. Area (Ac.)5.00Site Soil TypeSoil GroupPercentage of BasinCcB, CeB2B2.6 ac52.0%ChAB/D0.4 ac8.0%VnB2, VnC2C2.0 ac40.0%5.0 ac100.0%Hydrologic Soil Group UsedLand UseNo. AcresPercent of Drainage AreaCN for Group BGroup B Weighted CN CN for Group B/DGroup B/D Weighted CN CN for Group CGroup C Weighted CN Total Weighted CN Weighted CN %Wood (Good Cond.)3.5070.0%5528.6665.37028.0 61.9 43.3Open Space - Grass and Shurbs (Good Cond.)1.5030.0%6131.7715.77429.6 67.0 20.1Impervious0.000.0%9851.0987.89839.2 98.0 0.063.4Total5.0100%Composite Curve Number (CN):634Total Drain. Area (Ac.)4.00Site Soil TypeSoil GroupPercentage of BasinCcB, CeB2B2.5 ac62.5%ChAB/D0.3 ac7.5%VnB2, VnC2C1.2 ac30.0%4.0 ac100.0%Hydrologic Soil Group UsedLand UseNo. AcresPercent of Drainage AreaCN for Group BGroup B Weighted CN CN for Group B/DGroup B/D Weighted CN CN for Group CGroup C Weighted CN Total Weighted CN Weighted CN %Wood (Good Cond.)0.000.0%5534.4665.07021.0 60.3 0.0Open Space - Grass and Shurbs (Good Cond.)2.0852.0%6138.1715.37422.2 65.7 34.1Impervious1.9248.0%9861.3987.49829.4 98.0 47.081.2Total4.0100%Composite Curve Number (CN):81Existing Condition Watershed BMP #Proposed Development Watershed BMP #T:\PROJECTS\2017 PROJECTS\17031 The Village At Granite - LGI\CALCS\BMP\Phase 1\17031-PH1-Runoff CN.xlsSheet: 4 of 6 3/30/2018
Project: Village at GraniteDPR Job No.: 17031Location: Granite Quarry, NCDPR ASSOCIATES, INCRUN-OFF CURVE NUMBERPrepared by: RJChecked by: MBDate: 11-17-175Total Drain. Area (Ac.)2.50Site Soil TypeSoil GroupPercentage of BasinCcB, CeB2B0.0 ac0.0%ChAB/D0.0 ac0.0%VnB2, VnC2C2.5 ac100.0%2.5 ac100.0%Hydrologic Soil Group UsedLand UseNo. AcresPercent of Drainage AreaCN for Group BGroup B Weighted CN CN for Group B/DGroup B/D Weighted CN CN for Group CGroup C Weighted CN Total Weighted CN Weighted CN %Wood (Good Cond.)0.000.0%550.0660.07070.0 70.0 0.0Open Space - Grass and Shurbs (Good Cond.)2.50100.0%610.0710.07474.0 74.0 74.0Impervious0.000.0%980.0980.09898.0 98.0 0.074.0Total2.5100%Composite Curve Number (CN):74Existing Condition Watershed BMP #T:\PROJECTS\2017 PROJECTS\17031 The Village At Granite - LGI\CALCS\BMP\Phase 1\17031-PH1-Runoff CN.xlsSheet: 5 of 6 3/30/2018
Project: Village at GraniteDPR Job No.: 17031Location: Granite Quarry, NCDPR ASSOCIATES, INCRUN-OFF CURVE NUMBERPrepared by: RJChecked by: MBDate: 11-17-176Total Drain. Area (Ac.)5.50Site Soil TypeSoil GroupPercentage of BasinCeB2B4.3 ac78.2%ChAB/D0.0 ac0.0%VnB2, VnC2C1.2 ac21.8%5.5 ac100.0%Hydrologic Soil Group UsedLand UseNo. AcresPercent of Drainage AreaCN for Group BGroup B Weighted CN CN for Group B/DGroup B/D Weighted CN CN for Group CGroup C Weighted CN Total Weighted CN Weighted CN %Wood (Good Cond.)0.0%5543.0660.07015.3 58.3 0.0Open Space - Grass and Shurbs (Good Cond.)5.0090.9%6147.7710.07416.1 63.8 58.0Impervious0.509.1%9876.6980.09821.4 98.0 8.966.9Total5.5100%Composite Curve Number (CN):66.96Total Drain. Area (Ac.)6.00Site Soil TypeSoil GroupPercentage of BasinCeB2B4.8 ac80.0%ChAB/D0.0 ac0.0%VnB2, VnC2C1.2 ac20.0%6.0 ac100.0%Hydrologic Soil Group UsedLand UseNo. AcresPercent of Drainage AreaCN for Group BGroup B Weighted CN CN for Group B/DGroup B/D Weighted CN CN for Group CGroup C Weighted CN Total Weighted CN Weighted CN %Wood (Good Cond.)0.000.0%5544.0660.07014.0 58.0 0.0Open Space - Grass and Shurbs (Good Cond.)4.4073.3%6148.8710.07414.8 63.6 46.6Impervious1.6026.7%9878.4980.09819.6 98.0 26.172.8Total6.0100%Composite Curve Number (CN):73Existing Condition Watershed BMP #Proposed Development Watershed BMP #T:\PROJECTS\2017 PROJECTS\17031 The Village At Granite - LGI\CALCS\BMP\Phase 1\17031-PH1-Runoff CN.xlsSheet: 1 of 1 8/13/2018
Project: Village at GraniteDPR Job No.: 17031Location: Granite Quarry, NCDPR ASSOCIATES, INCRUN-OFF CURVE NUMBERPrepared by: RJChecked by: MBDate: 11-17-17Total Drain. Area (Ac.)4.30Site Soil TypeSoil GroupPercentage of BasinCeB2B3.0 ac69.8%ChAB/D0.0 ac0.0%VnB2, VnC2C1.3 ac30.2%4.3 ac100.0%Hydrologic Soil Group UsedLand UseNo. AcresPercent of Drainage AreaCN for Group BGroup B Weighted CN CN for Group B/DGroup B/D Weighted CN CN for Group CGroup C Weighted CN Total Weighted CN Weighted CN %Wood (Good Cond.)3.0069.8%5538.4660.07021.2 59.5 41.5Open Space - Grass and Shurbs (Good Cond.)1.2027.9%6142.6710.07422.4 64.9 18.1Impervious0.102.3%9868.4980.09829.6 98.0 2.361.9Total4.3100%Composite Curve Number (CN):61.9Total Drain. Area (Ac.)5.00Site Soil TypeSoil GroupPercentage of BasinCeB2B1.0 ac20.0%ChAB/D2.6 ac52.0%VnB2, VnC2C1.4 ac28.0%5.0 ac100.0%Hydrologic Soil Group UsedLand UseNo. AcresPercent of Drainage AreaCN for Group BGroup B Weighted CN CN for Group B/DGroup B/D Weighted CN CN for Group CGroup C Weighted CN Total Weighted CN Weighted CN %Wood (Good Cond.)0.000.0%5511.06634.37019.6 64.9 0.0Open Space - Grass and Shurbs (Good Cond.)4.7094.0%6112.27136.97420.7 69.8 65.6Impervious0.306.0%9819.69851.09827.4 98.0 5.971.5Total5.0100%Composite Curve Number (CN):72Existing Condition Undetain AreaProposed Development Undetain AreaT:\PROJECTS\2017 PROJECTS\17031 The Village At Granite - LGI\CALCS\BMP\Phase 1\17031-PH1-Runoff CN.xlsSheet: 1 of 1 8/13/2018
Project: Village at Granite
DPR Job No.: 17031
Location: Granite Quarry, NC
Sheet: 1 of 4
DPR ASSOCIATES
TIME OF CONCENTRATION
BMP 1
Prepared by:RJ
Checked by:HN
Date: 11-17-17
EXISTING CONDITION - TIME OF CONCENTRATION (BMP #1)
SHEET FLOW:
Surface Description = grass
Manning's Roughness (n) = 0.24
Flow Length (ft) = 150
Slope (%) = 2.0
P-2yr (in.) = 3.12
T(t) (min.) =20.0
SHALLOW CONCENTRATED FLOW:
Surface Description unpaved
Flow Length (ft) =470
Water Course Slope (%) = 6.00
Average Velocity (fps) =3.95
T(t) (min.) =2.0
T(t) Sum of Travel Time (min)= 22.0 Time =22 (min.)
Hydraulic Length = 620 ft
Basin Slope = 5.0
POST DEVELOPMENT - TIME OF CONCENTRATION
Time =5 (min.)
T:\PROJECTS\2017 PROJECTS\17031 The Village At Granite - LGI\CALCS\BMP\Phase 1\17031-TOCPlotted 12/21/2017 Sheet: 1 of 1
Project: Village at Granite
DPR Job No.: 17031
Location: Granite Quarry, NC
Page: 2 of 4
DPR ASSOCIATES
TIME OF CONCENTRATION
BMP 2
Prepared by: RJ
Checked by: HN
Date: 11-17-17
EXISTING CONDITION - TIME OF CONCENTRATION (BMP #2)
SHEET FLOW:
Surface Description = grass
Manning's Roughness (n) = 0.24
Flow Length (ft) = 150
Slope (%) = 4.0
P-2yr (in.) = 3.12
T(t) (min.) =15.1
SHALLOW CONCENTRATED FLOW:
Surface Description unpaved
Flow Length (ft) =430
Water Course Slope (%) = 7.00
Average Velocity (fps) =4.27
T(t) (min.) =1.7
CHANNEL FLOW:
Average Channel Area (sf) =4.00 Bottom Width (ft) = 2
Hydraulic Radius =0.618 Side Slope (X:1) = 2
Flow Length (ft) =235
Channel Slope (%) = 2 Depth (ft) =1
Manning's Coefficient (n) = 0.048
Velocity (fps) =3.19
T(t) (min.) =1.2
T(t) Sum of Travel Time (min)= 18.1 Time =18 (min.)
Hydraulic Length = 815 ft
Basin Slope = 5.0
POST DEVELOPMENT - TIME OF CONCENTRATION
Time =5 (min.)
T:\PROJECTS\2017 PROJECTS\17031 The Village At Granite - LGI\CALCS\BMP\Phase 1\17031-TOCPlotted 12/21/2017 Sheet: 1 of 1
Project: Village at Granite
DPR Job No.: 17031
Location: Granite Quarry, NC
Sheet: 3 of 4
DPR ASSOCIATES
TIME OF CONCENTRATION
BMP 3
Prepared by: RJ
Checked by: HN
Date: 11-17-17
EXISTING CONDITION - TIME OF CONCENTRATION (BMP #3)
SHEET FLOW:
Surface Description = grass
Manning's Roughness (n) = 0.24
Flow Length (ft) = 150
Slope (%) = 2.0
P-2yr (in.) = 3.12
T(t) (min.) =20.0
SHALLOW CONCENTRATED FLOW:
Surface Description unpaved
Flow Length (ft) =1180
Water Course Slope (%) = 3.50
Average Velocity (fps) =3.02
T(t) (min.) =6.5
T(t) Sum of Travel Time (min)= 26.5 Time =27 (min.)
Hydraulic Length = 1330 ft
Basin Slope = 3.3
POST DEVELOPMENT - TIME OF CONCENTRATION
Time =5 (min.)
T:\PROJECTS\2017 PROJECTS\17031 The Village At Granite - LGI\CALCS\BMP\Phase 1\17031-TOCPlotted 12/21/2017 Sheet: 1 of 1
Project: Village at Granite
DPR Job No.: 17031
Location: Granite Quarry, NC
Sheet: 4 of 4
DPR ASSOCIATES
TIME OF CONCENTRATION
BMP 4
Prepared by: RJ
Checked by: HN
Date:10-17-17
EXISTING CONDITION - TIME OF CONCENTRATION (BMP #4)
SHEET FLOW:
Surface Description = grass
Manning's Roughness (n) = 0.24
Flow Length (ft) = 150
Slope (%) = 6.7
P-2yr (in.) = 3.12
T(t) (min.) =12.3
SHALLOW CONCENTRATED FLOW:
Surface Description unpaved
Flow Length (ft) = 635
Water Course Slope (%) = 5.00
Average Velocity (fps) =3.61
T(t) (min.) =2.9
T(t) Sum of Travel Time (min)= 15.3 Time =15 (min.)
Hydraulic Length = 785 ft
Basin Slope = 5.3
POST DEVELOPMENT - TIME OF CONCENTRATION
Time =5 (min.)
T:\PROJECTS\2017 PROJECTS\17031 The Village At Granite - LGI\CALCS\BMP\Phase 1\17031-TOC.xlsPlotted 3/30/2018 Sheet: 1 of 1
Project: Sample
DPR Job No.: 00000.0
Location: Mecklenburg Co.
DPR ASSOCIATES
BMP
(Charlotte-Meck. Storm Water Design Manual)
Prepared by:XXX
Checked by:XXX
Date:X-XX-XX
EXISTING CONDITION - TIME OF CONCENTRATION (BMP #5)
SHEET FLOW:
Surface Description = grass
Manning's Roughness (n) = 0.24
Flow Length (ft) = 150
Slope (%) = 3.0
P-2yr (in.) = 3.12
T(t) (min.) =17.0
SHALLOW CONCENTRATED FLOW:
Surface Description unpaved
Flow Length (ft) = 130
Water Course Slope (%) = 3.00
Average Velocity (fps) =2.79
T(t) (min.) =0.8
T(t) Sum of Travel Time (min)= 17.8 Time =18 (min.)
Hydraulic Length = 280 ft
Basin Slope = 3.0
T:\PROJECTS\2017 PROJECTS\17031 The Village At Granite - LGI\CALCS\BMP\Phase 1\17031-TOC.xlsPlotted 3/30/2018 Sheet: 1 of 1
Project: Village at Granite
DPR Job No.: 17031
Location: Granite Quarry, NC
DPR ASSOCIATES
TIME OF CONCENTRATION
Prepared by: RJ
Checked by: HN
Date: 4-18-18
EXISTING CONDITION - TIME OF CONCENTRATION (BMP #6)
SHEET FLOW:
Surface Description = grass
Manning's Roughness (n) = 0.24
Flow Length (ft) = 100
Slope (%) = 5.5
P-2yr (in.) = 3.12
T(t) (min.) =9.6
CHANNEL FLOW:
Average Channel Area (sf) =4.00 Bottom Width (ft) = 2
Hydraulic Radius =0.618 Side Slope (X:1) = 2
Flow Length (ft) = 315
Channel Slope (%) = 2 Depth (ft) = 1
Manning's Coefficient (n) = 0.048
Velocity (fps) =3.19
T(t) (min.) =1.6
CHANNEL FLOW:
Average Channel Area (sf) =4.00 Bottom Width (ft) = 2
Hydraulic Radius =0.618 Side Slope (X:1) = 2
Flow Length (ft) = 148
Channel Slope (%) = 2 Depth (ft) = 1
Manning's Coefficient (n) = 0.048
Velocity (fps) =3.19
T(t) (min.) =0.8
T(t) Sum of Travel Time (min)= 12.1 Time =12 (min.)
Hydraulic Length = 563 ft
Basin Slope = 2.4
POST DEVELOPMENT - TIME OF CONCENTRATION
Time =5 (min.)
T:\PROJECTS\2017 PROJECTS\17031 The Village At Granite - LGI\CALCS\BMP\Phase 1\17031-PH1-TOC.xlsPlotted 8/13/2018 Sheet: 1 of 1
IV. BMP DESIGN AND CALCULATIONS
Project: Village at Granite
Job No.: 17031
Location: Granite Quarry, NC
Sheet: 1 of 3
DPR ASSOCIATES, INC
SAND FILTER-1 DESIGN
Prepared By: RJ
Checked By: HN
Date: 10-17-17
Revised: 12-21-17
DESIGN CRITERIA PER NCDENR STORMWATER DESIGN MANUAL DATED JAN 2017
* BMP - SAND FILTER - WATER QUALITY CONTROL ONLY 1
* Total Drainage Area (A):5.00 ac
* Total Impervious Area "I" USED = 2.40 ac
(See attached Impervious Calcs)
* Total Water Quality Volume To Treat (First 1" of Rainfall):
WQv = (P/12) (A) (Rv) (43560) =8,748 cf
(Simple Method, Schueler)
P: Water Quality Design Storm, 1st Inch of Rainfall 1 inch
A: Drainage Area (Impervious Area Only) 5.00 ac.
Rv: 0.05 + 0.009 (I) = 0.482
I: % of Impervious Area 48.0%
* Total Storm Water Volume Control 1-yr, 24-hr Post-Dev:
Qv = (P-0.2S)^2/ (P+0.8S) * A * (43560/12) =24,564 cf
(SCS Method)
P: Design Storm, 1-yr 24-hr Storm Rainfall depth 2.80 inch
A: Drainage Area 5.00 ac.
S = 1,000/CN-10 =1.90 inch
CN: Curve Number 84
* Estimated Storm Water Volume 10-yr, 24-hr Post-Dev:
Qv = (P-0.2S)^2/ (P+0.8S) * A * (43560/12) =34,526 cf
(SCS Method)
P: Design Storm, 10-yr 24-hr Storm Rainfall depth 3.46 inch
A: Drainage Area 5.00 ac.
S = 1000/CN-10 =1.90 inch
CN: Curve Number 84
* Sedimentation Chamber Volume Min. Required:
Vol-Pre = (0.2)(WQv) =1,750 cf
* Sedimentation Chamber Volume Provided:9,200 cf
* Filtration Media Surface Area Required:
Af=[(WQv) (Df)]/ [(k) (Hf + Df) (Tf)] =949 sf
(From Mecklenburg BMP Manual, Based on Darcy's Law)
WQv: Water quality volume 8,748 cf
Df: Filter bed depth (2'.5 for Optimal Efficiency)2.5 ft
k: Permeability coefficient of filter media 3.50 ft/day
(1.75" per hour, or 3.5' per day)
Hf: Average height of water above filter bed, (half of pond depth, 1' max)0.60 ft
Tf = Design filter bed drain time in days, (2 days beyond center 6-hr storm)2.125 days
Depth of Pond Water (24" Max.)=24 inch
* Filtration Media Surface Area Provided:1,000 sf
BMP Storage Volume Provided:
Elevation Surface Area Storage Total Storage
(ft) (sf) (cf) (cf)
729.5 Bottom of Stone - Provide liner per geo recommendation
730.5 Top of Stone/Bottom of Sand
733.0 Top of Sand Filter/ Bottom of Extended Dry Detention Pond
733.0 6,700 00Bottom of Pond
734.0 7,800 7,250 7,250
736.0 10,100 17,900 25,150
737.5 12,000 16,575 41,725 Top of Embankment
Static Water Quality Elevation @ 734.21 ft
Static Channel Protection Elevation @ 735.93 ft
48.0% (for Design)
SHWTE and groundwater @ 733.86' per Summit Geo Report letter dated 11-14-17
FEMA 100 Year Flood Elevation @ 727.8' (Flood Insurance Study dated 6-16-2009)
T:\PROJECTS\2017 PROJECTS\17031 The Village At Granite - LGI\CALCS\BMP\Phase 1\17031-PH1-BMP Sandfilter.xls
printed 8/13/2018
page 1 of 3
Project: Village at Granite
Job No.: 17031
Location: Granite Quarry, NC
Sheet: 2 of 3
DPR ASSOCIATES, INC
SAND FILTER-1 DESIGN
Prepared By: RJ
Checked By: HN
Date: 10-17-17
Revised: 12-21-17
* BMP - SAND FILTER 1
* Water Draw Down Flow Rate Thru Sand Filter Media
Qo = WQv / Tf = (Af)(k)(Hf+Df)/Df = 0.0692 cfs
(Darcy's Law)
k: Permeability coefficient of filter media 3.50 ft/day
Af: Surface area, sf 949 sf
Hf: Average height of water above filter bed 2.00 ft
Df: Depth of soil filter bed 2.5 ft
Q O @ Top of Media 733.0 = 0.0000 cfs
Q O @ Median of WQv storage 733.6 =0.0506 cfs
Q O @ Top of WQv storage 734.2 =0.0620 cfs
* Time Drawdown from Inundation to Saturation surface
Tf = WQv / Qo 35.13 hrs
* Sizing Under Drain Pipes
Q: Draw down rate thru sand filter 0.0692 cfs
Use [2]-17 lf of 6" PVC or Sch 40, Use 2 of
w/ 3/8" perforations spaced 3" on center, 4 rows w/ 90-deg apart 17 LF of 6 inch
# of Perforation = (# pipes)(4 rows/ft) (Linear feet/per pipe -2') (4 holes/row)
= (2 pipes)(4)(17 lf)(4)20 holes
Capacity of one hole (3/8") = CA(2gh)^(0.5)(orifice equation)0.0078 cfs
c= Discharge Coefficient 0.6
g= Accelleration, ft/sq.sec 32.2
a= Orifice Area (sf) of 3/8" hole 0.0008
h= head above perforation 4.5
Total Capacity = Capacity of 1 hole x # of holes 0.1566 cfs
Total Capacity w/ 50% lost to clogging 0.0783 cfs
Underdrain Pipe Capacity= 1.49/n(A)(A/P)^(2/3) (S)^0.5 (Manning Eq)0.395 cfs
n= pipe coefficient 0.013
A= Area (sf) of 6" dia pipe 0.1963
P= Pipe Perimeter, ft 1.57
s= slope, 0.5% 0.005
Underdrain Pipe Capacity w/ 50% lost to clogging 0.1974 cfs
Both Flow Rates thru Perforation and Pipe are greater than that of Flow rate of Sand Filter. OK
* Orifice Calcs For Channel Protection Dewatering Time 2 days (48 hrs) Beyond Center of 24-hr Storm
(Sized for the Volume of 1-yr Storm with 50% remained at 36th Hour, 5% remained at 60th Hour,
and drained completely at 120th Hour).
1-yr Storm Volume, Less 50% Remain Beyond 36th Hour 12,282 cf
Average Surface Area 4,192 sf
Area of Outlet Orifice (sf), a = (2)(A)h^(1/2))/(c)(t)(2g)^(1/2)) (NCDENR, Orifice Equation)
a = 0.023 where:
A= Resevoir Area, sf 4,192
Max. Orifice Diameter (inch), d = 2.04 h= Falling Head, ft 2.83
c= Discharge Coefficient 0.6
Orifice Diameter (inch) Used, d =2.5 t= Time ( 36 hrs), sec.129,600
g= Accelleration, ft/sq.sec 32.2
a= Orifice Area (sf)
d= Orifice Diameter (inch)
* 1-yr Storm CPv Draw Down Flow Rate Thru Sand Media
Qo = WQv / Tf 0.1137 cfs
(Darcy's Law)
CPv: 1-yr Storm Volume 24,564 cf
Tf: 2 days beyond center of 24hr-storm, 60 hours 216,000 sec
T:\PROJECTS\2017 PROJECTS\17031 The Village At Granite - LGI\CALCS\BMP\Phase 1\17031-PH1-BMP Sandfilter.xls
printed 8/13/2018
page 2 of 3
Project: Village at Granite
Job No.: 17031
Location: Granite Quarry, NC
Sheet: 3 of 3
DPR ASSOCIATES, INC
SAND FILTER-1 DESIGN
Prepared By: RJ
Checked By: HN
Date: 10-17-17
Revised: 12-21-17
* BMP - SAND FILTER 1
Anti-Seep Collar Sizing
Outlet Pipe Size (I.D.) = 18 in
Outlet Pipe Size (O.D.) = 1.92 ft
L, Length of Outlet Pipe = 40 lf
Min. Flow Length = 46.0 ft Min. Flow Length = 115% of outlet pipe
Total Lengh of Collar offset = 6.0 ft
Number of anti-seep collars 2
Offset per collar 3.0 ft
Min. Outside dimension of each collar 4.92 ft
Designed collars 2 at 5.0' x 5.0'
T:\PROJECTS\2017 PROJECTS\17031 The Village At Granite - LGI\CALCS\BMP\Phase 1\17031-PH1-BMP Sandfilter.xls
printed 8/13/2018
page 3 of 3
Pond Report 17
Hydraflow Hydrographs Extension for AutoCAD® Civil 3D® 2018 by Autodesk, Inc. v12 Monday, 08 / 13 / 2018
Pond No. 1 - PH1 BMP 1 - SANDFILTER
Pond Data
Contours -User-defined contour areas. Average end area method used for volume calculation. Begining Elevation = 733.00 ft
Stage / Storage Table
Stage (ft) Elevation (ft) Contour area (sqft) Incr. Storage (cuft) Total storage (cuft)
0.00 733.00 6,700 0 0
1.00 734.00 7,800 7,250 7,250
3.00 736.00 10,100 17,900 25,150
4.50 737.50 12,000 16,575 41,725
Culvert / Orifice Structures Weir Structures
[A] [B] [C] [PrfRsr] [A] [B] [C] [D]
Rise (in)= 18.00 3.00 6.00 0.00
Span (in)= 18.00 3.00 160.00 0.00
No. Barrels = 1 110
Invert El. (ft)= 728.35 734.10 736.00 0.00
Length (ft)= 66.00 0.50 0.50 0.00
Slope (%)= 0.50 0.00 0.00 n/a
N-Value = .013 .013 .013 n/a
Orifice Coeff.= 0.60 0.60 0.60 0.60
Multi-Stage = n/a Yes Yes No
Crest Len (ft)= 10.00 0.00 0.00 0.00
Crest El. (ft)= 736.50 0.00 0.00 0.00
Weir Coeff.= 2.60 3.33 3.33 3.33
Weir Type = Broad --- --- ---
Multi-Stage = No No No No
Exfil.(in/hr)= 0.000 (by Contour)
TW Elev. (ft)= 0.00
Note: Culvert/Orifice outflows are analyzed under inlet (ic) and outlet (oc) control. Weir risers checked for orifice conditions (ic) and submergence (s).
0.00 5.00 10.00 15.00 20.00 25.00 30.00 35.00 40.00 45.00 50.00
Stage (ft)
0.00 733.00
1.00 734.00
2.00 735.00
3.00 736.00
4.00 737.00
5.00 738.00
Elev (ft)
Discharge (cfs)
Stage / Discharge
Total Q
Project: Village at Granite
Job No.: 17031
Location: Granite Quarry, NC
Sheet: 1 of 3
DPR ASSOCIATES, INC
SAND FILTER-2 DESIGN
Prepared By: RJ
Checked By: HN
Date: 11-17-17
Revised: 12-21-17
DESIGN CRITERIA PER NCDENR STORMWATER DESIGN MANUAL DATED JAN 2017
* BMP - SAND FILTER - WATER QUALITY CONTROL ONLY 2
* Total Drainage Area (A):9.00 ac
* Total Impervious Area "I" USED = 4.32 ac
(See attached Impervious Calcs)
* Total Water Quality Volume To Treat (First 1" of Rainfall):
WQv = (P/12) (A) (Rv) (43560) =15,747 cf
(Simple Method, Schueler)
P: Water Quality Design Storm, 1st Inch of Rainfall 1 inch
A: Drainage Area (Impervious Area Only) 9.00 ac.
Rv: 0.05 + 0.009 (I) = 0.482
I: % of Impervious Area 48.0%
* Total Storm Water Volume Control 1-yr, 24-hr Post-Dev:
Qv = (P-0.2S)^2/ (P+0.8S) * A * (43560/12) =48,760 cf
(SCS Method)
P: Design Storm, 1-yr 24-hr Storm Rainfall depth 2.8 inch
A: Drainage Area 9.00 ac.
S = 1,000/CN-10 =1.63 inch
CN: Curve Number 86
* Estimated Storm Water Volume 10-yr, 24-hr Post-Dev:
Qv = (P-0.2S)^2/ (P+0.8S) * A * (43560/12) =67,398 cf
(SCS Method)
P: Design Storm, 10-yr 24-hr Storm Rainfall depth 3.46 inch
A: Drainage Area 9.00 ac.
S = 1000/CN-10 =1.63 inch
CN: Curve Number 86
* Sedimentation Chamber Volume Min. Required:
Vol-Pre = (0.2)(WQv) =3,149 cf
* Sedimentation Chamber Volume Provided:13,000 cf
* Filtration Media Surface Area Required:
Af=[(WQv) (Df)]/ [(k) (Hf + Df) (Tf)] =1,616 sf
(From Mecklenburg BMP Manual, Based on Darcy's Law)
WQv: Water quality volume 15,747 cf
Df: Filter bed depth (2'.5 for Optimal Efficiency)2.5 ft
k: Permeability coefficient of filter media 3.50 ft/day
(1.75" per hour, or 3.5' per day)
Hf: Average height of water above filter bed, (half of pond depth, 1' max)0.78 ft
Tf = Design filter bed drain time in days, (2 days beyond center 6-hr storm)2.125 days
Depth of Pond Water (24" Max.)=24 inch
* Filtration Media Surface Area Provided:2,000 sf
BMP Storage Volume Provided:
Elevation Surface Area Incremental Storage Total Storage
(ft) (sf) (cf) (cf)
724.5 Bottom of Stone
725.5 Top of Stone/Bottom of Sand
728.0 Top of Sand Filter/ Bottom of Extended Dry Detention Pond
728.0 5,300 00Bottom of Pond
730.0 13,500 18,800 18,800
732.0 17,100 30,600 49,400
734.0 20,900 38,000 87,400 Top of Embankment
Static Water Quality Elevation @ 729.68 ft
Static Channel Protection Elevation @ 731.96 ft
48.0% (for Design)
SHWTE and groundwater @ 719.73' per Summit Geo Report letter dated 11-14-17
FEMA 100 Year Flood Elevation @ 725.0' (Flood Insurance Study dated 6-16-2009)
T:\PROJECTS\2017 PROJECTS\17031 The Village At Granite - LGI\CALCS\BMP\Phase 1\17031-PH1-BMP Sandfilter.xls
printed 8/13/2018
page 1 of 3
Project: Village at Granite
Job No.: 17031
Location: Granite Quarry, NC
Sheet: 2 of 3
DPR ASSOCIATES, INC
SAND FILTER-2 DESIGN
Prepared By: RJ
Checked By: HN
Date: 11-17-17
Revised: 12-21-17
* BMP - SAND FILTER 2
* Water Draw Down Flow Rate Thru Sand Filter Media
Qo = WQv / Tf = (Af)(k)(Hf+Df)/Df = 0.1178 cfs
(Darcy's Law)
k: Permeability coefficient of filter media 3.50 ft/day
Af: Surface area, sf 1,616 sf
Hf: Average height of water above filter bed 2.00 ft
Df: Depth of soil filter bed 2.5 ft
Q O @ Top of Media 728.0 = 0.0000 cfs
Q O @ Median of WQv storage 728.8 =0.0506 cfs
Q O @ Top of WQv storage 729.7 =0.0620 cfs
* Time Drawdown from Inundation to Saturation surface
Tf = WQv / Qo 37.12 hrs
* Sizing Under Drain Pipes
Q: Draw down rate thru sand filter 0.1178 cfs
Use [2]-17 lf of 6" PVC or Sch 40, Use 2 of
w/ 3/8" perforations spaced 3" on center, 4 rows w/ 90-deg apart 17 LF of 6 inch
# of Perforation = (# pipes)(4 rows/ft) (Linear feet/per pipe -2') (4 holes/row)
= (2 pipes)(4)(17 lf)(4)20 holes
Capacity of one hole (3/8") = CA(2gh)^(0.5)(orifice equation)0.0078 cfs
c= Discharge Coefficient 0.6
g= Accelleration, ft/sq.sec 32.2
a= Orifice Area (sf) of 3/8" hole 0.0008
h= head above perforation 4.5
Total Capacity = Capacity of 1 hole x # of holes 0.1566 cfs
Total Capacity w/ 50% lost to clogging 0.0783 cfs
Underdrain Pipe Capacity= 1.49/n(A)(A/P)^(2/3) (S)^0.5 (Manning Eq)0.395 cfs
n= pipe coefficient 0.013
A= Area (sf) of 6" dia pipe 0.1963
P= Pipe Perimeter, ft 1.57
s= slope, 0.5% 0.005
Underdrain Pipe Capacity w/ 50% lost to clogging 0.1974 cfs
Both Flow Rates thru Perforation and Pipe are greater than that of Flow rate of Sand Filter. OK
* Orifice Calcs For Channel Protection Dewatering Time 2 days (48 hrs) Beyond Center of 24-hr Storm
(Sized for the Volume of 1-yr Storm with 50% remained at 36th Hour, 5% remained at 60th Hour,
and drained completely at 120th Hour).
yr Storm Volume, Less 50% Remain Beyond 36th Hour 24,380 cf
Average Surface Area 14,512 sf
Area of Outlet Orifice (sf), a = (2)(A)h^(1/2))/(c)(t)(2g)^(1/2)) (NCDENR, Orifice Equation)
a = 0.058 where:
A= Resevoir Area, sf 14,512
Max. Orifice Diameter (inch), d = 3.28 h= Falling Head, ft 1.58
c= Discharge Coefficient 0.6
Orifice Diameter (inch) Used, d =2.5 t= Time ( 36 hrs ), sec.129,600
g= Accelleration, ft/sq.sec 32.2
a= Orifice Area (sf)
d= Orifice Diameter (inch)
* 1-yr Storm CPv Draw Down Flow Rate Thru Sand Media
Qo = WQv / Tf 0.2257 cfs
(Darcy's Law)
CPv: 1-yr Storm Volume 48,760 cf
Tf: 2 days beyond center of 24hr-storm, 60 hours 216,000 sec
T:\PROJECTS\2017 PROJECTS\17031 The Village At Granite - LGI\CALCS\BMP\Phase 1\17031-PH1-BMP Sandfilter.xls
printed 8/13/2018
page 2 of 3
Project: Village at Granite
Job No.: 17031
Location: Granite Quarry, NC
Sheet: 3 of 3
DPR ASSOCIATES, INC
SAND FILTER-2 DESIGN
Prepared By: RJ
Checked By: HN
Date: 11-17-17
Revised: 12-21-17
* BMP - SAND FILTER 2
Anti-Seep Collar Sizing
Outlet Pipe Size (I.D.) = 36 in
Outlet Pipe Size (O.D.) = 3.67 ft
L, Length of Outlet Pipe = 38 lf
Min. Flow Length = 43.7 ft Min. Flow Length = 115% of outlet pipe
Total Lengh of Collar offset = 5.7 ft
Number of anti-seep collars 2
Offset per collar 2.9 ft
Min. Outside dimension of each collar 6.52 ft
Designed collars 2 at 6.5' x 6.5'
T:\PROJECTS\2017 PROJECTS\17031 The Village At Granite - LGI\CALCS\BMP\Phase 1\17031-PH1-BMP Sandfilter.xls
printed 8/13/2018
page 3 of 3
Pond Report 19
Hydraflow Hydrographs Extension for AutoCAD® Civil 3D® 2018 by Autodesk, Inc. v12 Monday, 08 / 13 / 2018
Pond No. 2 - PH1 BMP 2 - SANDFILTER
Pond Data
Contours -User-defined contour areas. Average end area method used for volume calculation. Begining Elevation = 728.00 ft
Stage / Storage Table
Stage (ft) Elevation (ft) Contour area (sqft) Incr. Storage (cuft) Total storage (cuft)
0.00 728.00 5,300 0 0
2.00 730.00 13,500 18,800 18,800
4.00 732.00 17,100 30,600 49,400
6.00 734.00 20,900 38,000 87,400
Culvert / Orifice Structures Weir Structures
[A] [B] [C] [PrfRsr] [A] [B] [C] [D]
Rise (in)= 36.00 3.00 6.00 0.00
Span (in)= 36.00 3.00 204.00 0.00
No. Barrels = 1 110
Invert El. (ft)= 724.33 729.80 731.80 0.00
Length (ft)= 32.00 0.50 0.50 0.00
Slope (%)= 1.00 0.00 0.00 n/a
N-Value = .013 .013 .013 n/a
Orifice Coeff.= 0.60 0.60 0.60 0.60
Multi-Stage = n/a Yes Yes No
Crest Len (ft)= 0.00 0.00 0.00 0.00
Crest El. (ft)= 0.00 0.00 0.00 0.00
Weir Coeff.= 3.33 3.33 3.33 3.33
Weir Type = --- --- --- ---
Multi-Stage = No No No No
Exfil.(in/hr)= 0.000 (by Contour)
TW Elev. (ft)= 0.00
Note: Culvert/Orifice outflows are analyzed under inlet (ic) and outlet (oc) control. Weir risers checked for orifice conditions (ic) and submergence (s).
0.00 6.00 12.00 18.00 24.00 30.00 36.00 42.00 48.00 54.00 60.00
Stage (ft)
0.00 728.00
1.00 729.00
2.00 730.00
3.00 731.00
4.00 732.00
5.00 733.00
6.00 734.00
Elev (ft)
Discharge (cfs)
Stage / Discharge
Total Q
Project: Village at Granite - Phase1
Job No.: 17031
Location: Granite Quarry, NC
Sheet: 1 of 2
DPR ASSOCIATES
BMP WETPOND #3 DESIGN
Prepared By: RJ
Checked By: HN
Date: 10-17-17
Revised: 2-26-18, RJ
DESIGN CRITERIA PER NCDENR STORMWATER DESIGN MANUAL DATED JAN 2017
* BMP WET DETENTION POND 3
* Total Drainage Area (A):22.00 ac
* Total Impervious Area "I" USED = 10.56 ac
(See attached Impervious Calcs)
* Total Water Quality Volume To Treat (First 1" of Rainfall):
WQv = (P/12) (A) (Rv) (43,560) =38,493 cf
(Simple Method, Schueler)
P: Water Quality Design Storm, 1st 1-Inch of Rainfall 1 inch
A: Drainage Area 22.00 ac.
Rv: 0.05 + 0.009 (I) = 0.482
I: % of Impervious Area 48.0%
* Main Pool:
Pool Average Depth (H)=6.5 ft
Surface Area to Drainage Area Ratio (SA/DA)= (NCDENR Table 1 )1.04
Required Surface Area (SA)=9,967 sf
Provided Surface Area (SA) @ Perm. W.S. Elev.=18,000 sf
Required Pool Volume (V= SA*H)=64,782 cf
Provided Pool Volume (V) @ Perm. W.S. Elev.=74,500 cf
* Forebay:
Required Forebay Volume (20% of Pool Volume)=12,956 cf
Provided Forbay Volume @ Perm. W.S. Elev.=13,000 cf
* Estimated Storm Water Volume 1-yr, 24-hr Post-Dev:108,082 cf
Qv = (P-0.2S)^2/ (P+0.8S) * A * (43,560/12) =
(SCS Method)
P: Design Storm, 1-yr 24-hr Storm Rainfall depth 2.8 inch
A: Drainage Area 22.00 ac.
S = 1000/CN-10 =1.90 inch
CN: Curve Number 84
* Estimated Storm Water Volume 10-yr, 24-hr Post-Dev:
Qv = (P-0.2S)^2/ (P+0.8S) * A * (43,560/12) =151,915 cf
(SCS Method)
P: Design Storm, 10-yr 24-hr Storm Rainfall depth 3.46 inch
A: Drainage Area 22.00 ac.
S = 1000/CN-10 =1.90 inch
CN: Curve Number 84
BMP Pond Storage Volume Provided:
Stage Surface Area Incremental Storage Total Storage
(ft) (sf) (cf) (cf) Notes
716.0 2,000 0 0 Bottom of Pond
718.0 11,300 13,300 13,300
720.0 13,200 24,500 37,800
722.0 15,200 28,400 66,200
722.5 (Perm. W.S.) 18,000 8,300 74,500 Top of Perm. Pool
722.5 (Perm. W.S.) 18,000 0 0 Bottom of Temp. Pool
723.0 21,400 9,850 9,850
724.0 23,500 22,450 32,300
724.5 24,600 12,025 44,325
726.0 27,900 39,375 83,700
728.0 32,400 60,300 144,000
729.0 34,800 33,600 177,600
729.5 36,200 17,750 195,350 Top of Embankment
Static Water Quality Elevation @ 724.26 ft
Static Channel Protection Elevation @ 726.81 ft
48.0% (for Design)
SHWTE and groundwater @ 722.28' per Summit Geo Report letter dated 11-14-17
FEMA 100 Year Flood Elevation @ 724.14' (DPR Flood Study dated 6-1-2018)
T:\PROJECTS\2017 PROJECTS\17031 The Village At Granite - LGI\CALCS\BMP\Phase 1\17031-PH1-BMP Wet Pond.xls printed 8/13/2018
Project: Village at Granite - Phase1
Job No.: 17031
Location: Granite Quarry, NC
Sheet: 2 of 2
DPR ASSOCIATES
BMP WETPOND #3 DESIGN
Prepared By: RJ
Checked By: HN
Date: 10-17-17
Revised: 2-26-18, RJ
* BMP POND 3
* Orifice Calculations For Detawering Time Between 24 hrs to 120 hrs
WQv 38,493 cf
Average Surface Area 21,871 sf
Area of Outlet Orifice (sf), a = (2)(A)h^(1/2))/(c)(t)(2g)^(1/2)) (NCDENR, Orifice Equation)
a =0.084 where:
A= Resevoir Area, sf 21,871
Min. Orifice Diameter (inch), d =3.93 h= Falling Head, ft 1.76
c= Discharge Coefficient 0.5
Orifice Diameter (inch) Used, d =3.0 t= Time (48 Hrs), sec. 172,800
g= Accelleration, ft/sq.sec 32.2
a= Orifice Area (sf)
d= Orifice Diameter (inch)
Emergency Drain Orifice Calculations For Permanent Pond Within 24 hrs
Permanent Pool Volume 74,500 cf
Average Surface Area 11,462 sf
Area of Outlet Orifice (sf), a = (2)(A)h^(1/2))/(c)(t)(2g)^(1/2)) (NCDENR, Orifice Equation)
a =0.169 where:
A= Resevoir Area, sf 11,462
Min. Orifice Diameter (inch), d =5.58 h= Falling Head, ft 6.50
c= Discharge Coefficient 0.5
Orifice Diameter (inch) Used, d =5.0 t= Time (24 Hrs), sec. 86,400
g= Accelleration, ft/sq.sec 32.2
a= Orifice Area (sf)
d= Orifice Diameter (inch)
Anti-Seep Collar Sizing
Outlet Pipe Size (I.D.) = 36 in
Outlet Pipe Size (O.D.) = 3.67 ft
L, Length of Outlet Pipe = 96 lf
Min. Flow Length = 110.4 ft Min. Flow Length = 115% of outlet pipe length
Total Lengh of Collar offset = 14.4 ft
Number of anti-seep collars 2
Offset per collar 7.2 ft
Min. Outside dimension of each collar 10.87 ft
Designed collars 2 at 10' x 10'
T:\PROJECTS\2017 PROJECTS\17031 The Village At Granite - LGI\CALCS\BMP\Phase 1\17031-PH1-BMP Wet Pond.xls printed 8/13/2018
Pond Report 21
Hydraflow Hydrographs Extension for AutoCAD® Civil 3D® 2018 by Autodesk, Inc. v12 Monday, 08 / 13 / 2018
Pond No. 3 - PH1 BMP 3 - WET POND
Pond Data
Contours -User-defined contour areas. Average end area method used for volume calculation. Begining Elevation = 722.50 ft
Stage / Storage Table
Stage (ft) Elevation (ft) Contour area (sqft) Incr. Storage (cuft) Total storage (cuft)
0.00 722.50 18,000 0 0
0.50 723.00 21,400 9,850 9,850
1.50 724.00 23,500 22,450 32,300
2.00 724.50 24,600 12,025 44,325
3.50 726.00 27,900 39,375 83,700
5.50 728.00 32,400 60,300 144,000
6.50 729.00 34,800 33,600 177,600
7.00 729.50 36,200 17,750 195,350
Culvert / Orifice Structures Weir Structures
[A] [B] [C] [PrfRsr] [A] [B] [C] [D]
Rise (in)= 36.00 3.00 6.00 0.00
Span (in)= 36.00 3.00 204.00 0.00
No. Barrels = 1 110
Invert El. (ft)= 719.45 722.50 726.50 0.00
Length (ft)= 90.00 0.50 0.50 0.00
Slope (%)= 0.50 0.00 0.00 n/a
N-Value = .013 .013 .013 n/a
Orifice Coeff.= 0.60 0.60 0.60 0.60
Multi-Stage = n/a Yes Yes No
Crest Len (ft)= 10.00 0.00 0.00 0.00
Crest El. (ft)= 728.00 0.00 0.00 0.00
Weir Coeff.= 2.60 3.33 3.33 3.33
Weir Type = Broad --- --- ---
Multi-Stage = No No No No
Exfil.(in/hr)= 0.000 (by Contour)
TW Elev. (ft)= 723.00
Note: Culvert/Orifice outflows are analyzed under inlet (ic) and outlet (oc) control. Weir risers checked for orifice conditions (ic) and submergence (s).
0.0 10.0 20.0 30.0 40.0 50.0 60.0 70.0 80.0 90.0 100.0 110.0 120.0
Stage (ft)
0.00 722.50
2.00 724.50
4.00 726.50
6.00 728.50
8.00 730.50
Elev (ft)
Discharge (cfs)
Stage / Discharge
Total Q
Project: Village at Granite
Job No.: 17031
Location: Granite Quarry, NC
Sheet: 1 of 3
DPR ASSOCIATES, INC
SAND FILTER-4 DESIGN
Prepared By: RJ
Checked By: HN
Date: 11-17-17
Revised 12-21-17
DESIGN CRITERIA PER NCDENR STORMWATER DESIGN MANUAL DATED JAN 2017
* BMP - SAND FILTER - WATER QUALITY CONTROL ONLY 4
* Total Drainage Area (A):4.00 ac
* Total Impervious Area "I" USED = 1.92 ac
(See attached Impervious Calcs)
* Total Water Quality Volume To Treat (First 1" of Rainfall):
WQv = (P/12) (A) (Rv) (43560) =6,999 cf
(Simple Method, Schueler)
P: Water Quality Design Storm, 1st Inch of Rainfall 1 inch
A: Drainage Area (Impervious Area Only) 4.00 ac.
Rv: 0.05 + 0.009 (I) = 0.482
I: % of Impervious Area 48.0%
* Total Storm Water Volume Control 1-yr, 24-hr Post-Dev:
Qv = (P-0.2S)^2/ (P+0.8S) * A * (43560/12) =16,868 cf
(SCS Method)
P: Design Storm, 1-yr 24-hr Storm Rainfall depth 2.8 inch
A: Drainage Area 4.00 ac.
S = 1,000/CN-10 =2.35 inch
CN: Curve Number 81
* Estimated Storm Water Volume 10-yr, 24-hr Post-Dev:
Qv = (P-0.2S)^2/ (P+0.8S) * A * (43560/12) =24,339 cf
(SCS Method)
P: Design Storm, 10-yr 24-hr Storm Rainfall depth 3.46 inch
A: Drainage Area 4.00 ac.
S = 1000/CN-10 =2.35 inch
CN: Curve Number 81
* Sedimentation Chamber Volume Min. Required:
Vol-Pre = (0.2)(WQv) =1,400 cf
* Sedimentation Chamber Volume Provided:3,200 cf
* Filtration Media Surface Area Required:
Af=[(WQv) (Df)]/ [(k) (Hf + Df) (Tf)] =684 sf
(From Mecklenburg BMP Manual, Based on Darcy's Law)
WQv: Water quality volume 6,999 cf
Df: Filter bed depth (2'.5 for Optimal Efficiency)2.5 ft
k: Permeability coefficient of filter media 3.50 ft/day
(1.75" per hour, or 3.5' per day)
Hf: Average height of water above filter bed, (half of pond depth, 1' max)0.94 ft
Tf = Design filter bed drain time in days, (2 days beyond center 6-hr storm)2.125 days
Depth of Pond Water (24" Max.)=24 inch
* Filtration Media Surface Area Provided:700 sf
BMP Storage Volume Provided:
Elevation Surface Area Incremental Storage Total Storage
(ft) (sf) (cf) (cf)
720.5 Bottom of Stone
721.5 Top of Stone/Bottom of Sand
724.0 Top of Sand Filter/ Bottom of Extended Dry Detention Pond
724.0 3,600 00Bottom of Pond
726.0 5,600 9,200 9,200
728.0 7,800 13,400 22,600
730.0 10,300 18,100 40,700 Top of Embankment
Static Water Quality Elevation @ 725.52 ft
Static Channel Protection Elevation @ 727.14 ft
48.0% (for Design)
SHWTE and groundwater @ 708.71' per Summit Geo Report letter dated 11-14-17
FEMA 100 Year Flood Elevation @ 723.37' (DPR Flood Study dated 6-1-2018)
T:\PROJECTS\2017 PROJECTS\17031 The Village At Granite - LGI\CALCS\BMP\Phase 1\17031-PH1-BMP Sandfilter.xls
printed 8/13/2018
page 1 of 3
Project: Village at Granite
Job No.: 17031
Location: Granite Quarry, NC
Sheet: 2 of 3
DPR ASSOCIATES, INC
SAND FILTER-4 DESIGN
Prepared By: RJ
Checked By: HN
Date: 11-17-17
Revised 12-21-17
* BMP - SAND FILTER 4
* Water Draw Down Flow Rate Thru Sand Filter Media
Qo = WQv / Tf = (Af)(k)(Hf+Df)/Df = 0.0499 cfs
(Darcy's Law)
k: Permeability coefficient of filter media 3.50 ft/day
Af: Surface area, sf 684 sf
Hf: Average height of water above filter bed 2.00 ft
Df: Depth of soil filter bed 2.5 ft
Q O @ Top of Media 724.0 = 0.0000 cfs
Q O @ Median of WQv storage 724.8 =0.0506 cfs
Q O @ Top of WQv storage 725.5 =0.0620 cfs
* Time Drawdown from Inundation to Saturation surface
Tf = WQv / Qo 38.99 hrs
* Sizing Under Drain Pipes
Q: Draw down rate thru sand filter 0.0499 cfs
Use [2]-17 lf of 6" PVC or Sch 40, Use 2 of
w/ 3/8" perforations spaced 3" on center, 4 rows w/ 90-deg apart 17 LF of 6 inch
# of Perforation = (# pipes)(4 rows/ft) (Linear feet/per pipe -2') (4 holes/row)
= (2 pipes)(4)(17 lf)(4)20 holes
Capacity of one hole (3/8") = CA(2gh)^(0.5)(orifice equation)0.0078 cfs
c= Discharge Coefficient 0.6
g= Accelleration, ft/sq.sec 32.2
a= Orifice Area (sf) of 3/8" hole 0.0008
h= head above perforation 4.5
Total Capacity = Capacity of 1 hole x # of holes 0.1566 cfs
Total Capacity w/ 50% lost to clogging 0.0783 cfs
Underdrain Pipe Capacity= 1.49/n(A)(A/P)^(2/3) (S)^0.5 (Manning Eq)0.395 cfs
n= pipe coefficient 0.013
A= Area (sf) of 6" dia pipe 0.1963
P= Pipe Perimeter, ft 1.57
s= slope, 0.5% 0.005
Underdrain Pipe Capacity w/ 50% lost to clogging 0.1974 cfs
Both Flow Rates thru Perforation and Pipe are greater than that of Flow rate of Sand Filter. OK
* Orifice Calcs For Channel Protection Dewatering Time 2 days (48 hrs) Beyond Center of 24-hr Storm
(Sized for the Volume of 1-yr Storm with 50% remained at 36th Hour, 5% remained at 60th Hour,
and drained completely at 120th Hour).
1-yr Storm Volume, Less 50% Remain Beyond 36th Hour 8,434 cf
Average Surface Area 5,549 sf
Area of Outlet Orifice (sf), a = (2)(A)h^(1/2))/(c)(t)(2g)^(1/2)) (NCDENR, Orifice Equation)
a = 0.021 where:
A= Resevoir Area, sf 5,549
Max. Orifice Diameter (inch), d = 1.98 h= Falling Head, ft 1.42
c= Discharge Coefficient 0.6
Orifice Diameter (inch) Used, d =2.5 t= Time ( 36 hrs), sec.129,600
g= Accelleration, ft/sq.sec 32.2
a= Orifice Area (sf)
d= Orifice Diameter (inch)
* 1-yr Storm CPv Draw Down Flow Rate Thru Sand Media
Qo = WQv / Tf 0.0781 cfs
(Darcy's Law)
CPv: 1-yr Storm Volume 16,868 cf
Tf: 2 days beyond center of 24hr-storm, 60 hours 216,000 sec
T:\PROJECTS\2017 PROJECTS\17031 The Village At Granite - LGI\CALCS\BMP\Phase 1\17031-PH1-BMP Sandfilter.xls
printed 8/13/2018
page 2 of 3
Project: Village at Granite
Job No.: 17031
Location: Granite Quarry, NC
Sheet: 3 of 3
DPR ASSOCIATES, INC
SAND FILTER-4 DESIGN
Prepared By: RJ
Checked By: HN
Date: 11-17-17
Revised 12-21-17
* BMP - SAND FILTER 4
Anti-Seep Collar Sizing
Outlet Pipe Size (I.D.) = 24 in
Outlet Pipe Size (O.D.) = 2.50 ft
L, Length of Outlet Pipe = 40 lf
Min. Flow Length = 46.0 ft Min. Flow Length = 115% of outlet pipe
Total Lengh of Collar offset = 6.0 ft
Number of anti-seep collars 2
Offset per collar 3.0 ft
Min. Outside dimension of each collar 5.50 ft
Designed collars 2 at 5.5' x 5.5'
T:\PROJECTS\2017 PROJECTS\17031 The Village At Granite - LGI\CALCS\BMP\Phase 1\17031-PH1-BMP Sandfilter.xls
printed 8/13/2018
page 3 of 3
Pond Report 23
Hydraflow Hydrographs Extension for AutoCAD® Civil 3D® 2018 by Autodesk, Inc. v12 Monday, 08 / 13 / 2018
Pond No. 4 - PH1 BMP 4 - SANDFILTER
Pond Data
Contours -User-defined contour areas. Average end area method used for volume calculation. Begining Elevation = 724.00 ft
Stage / Storage Table
Stage (ft) Elevation (ft) Contour area (sqft) Incr. Storage (cuft) Total storage (cuft)
0.00 724.00 3,600 0 0
2.00 726.00 5,600 9,200 9,200
4.00 728.00 7,800 13,400 22,600
6.00 730.00 10,300 18,100 40,700
Culvert / Orifice Structures Weir Structures
[A] [B] [C] [PrfRsr] [A] [B] [C] [D]
Rise (in)= 24.00 3.00 6.00 0.00
Span (in)= 24.00 3.00 160.00 0.00
No. Barrels = 1 110
Invert El. (ft)= 720.40 725.60 727.20 0.00
Length (ft)= 40.00 0.50 0.50 0.00
Slope (%)= 1.00 0.00 0.00 n/a
N-Value = .013 .013 .013 n/a
Orifice Coeff.= 0.60 0.60 0.60 0.60
Multi-Stage = n/a Yes Yes No
Crest Len (ft)= 0.00 0.00 0.00 0.00
Crest El. (ft)= 0.00 0.00 0.00 0.00
Weir Coeff.= 3.33 3.33 3.33 3.33
Weir Type = --- --- --- ---
Multi-Stage = No No No No
Exfil.(in/hr)= 0.000 (by Contour)
TW Elev. (ft)= 0.00
Note: Culvert/Orifice outflows are analyzed under inlet (ic) and outlet (oc) control. Weir risers checked for orifice conditions (ic) and submergence (s).
0.00 4.00 8.00 12.00 16.00 20.00 24.00 28.00 32.00 36.00 40.00 44.00
Stage (ft)
0.00 724.00
1.00 725.00
2.00 726.00
3.00 727.00
4.00 728.00
5.00 729.00
6.00 730.00
Elev (ft)
Discharge (cfs)
Stage / Discharge
Total Q
Project: Village at Granite
Job No.: 17031
Location: Granite Quarry, NC
Sheet: 1 of 2
DPR ASSOCIATES, INC
SAND FILTER-1 DESIGN
Prepared By: RJ
Checked By: HN
Date: 10-17-17
Revised: 12-21-17
DESIGN CRITERIA PER NCDENR STORMWATER DESIGN MANUAL DATED JAN 2017
* BMP - DRY POND 6
* Total Drainage Area:6.00 ac
* Total Storm Water Volume Control 1-yr, 24-hr Post-Dev:
Qv = (P-0.2S)^2/ (P+0.8S) * A * (43560/12) =12,315 cf
(SCS Method)
P: Design Storm, 1-yr 24-hr Storm Rainfall depth 2.80 inch
A: Drainage Area 6.00 ac.
S = 1,000/CN-10 =4.49 inch
CN: Curve Number 69
* Estimated Storm Water Volume 10-yr, 24-hr Post-Dev:
Qv = (P-0.2S)^2/ (P+0.8S) * A * (43560/12) =20,257 cf
(SCS Method)
P: Design Storm, 10-yr 24-hr Storm Rainfall depth 3.46 inch
A: Drainage Area 6.00 ac.
S = 1000/CN-10 =4.49 inch
CN: Curve Number 69
BMP Storage Volume Provided:
Elevation Surface Area Storage Total Storage
(ft) (sf) (cf) (cf)
753.0 50 00Bottom of Pond
754.0 5,000 2,525 2,525
756.0 7,000 12,000 14,525
758.0 23,100 30,100 44,625
760.0 58,300 81,400 126,025 Top of Embankment
Static Channel Protection Elevation @ 755.64 ft
* Orifice Calcs For Channel Protection Dewatering Time 2 days (48 hrs) Beyond Center of 24-hr Storm
(Sized for the Volume of 1-yr Storm with 50% remained at 36th Hour, 5% remained at 60th Hour,
and drained completely at 120th Hour).
1-yr Storm Volume, Less 50% Remain Beyond 36th Hour 6,158 cf
Average Surface Area 2,332 sf
Area of Outlet Orifice (sf), a = (2)(A)h^(1/2))/(c)(t)(2g)^(1/2)) (NCDENR, Orifice Equation)
a = 0.012 where:
A= Resevoir Area, sf 2,332
Max. Orifice Diameter (inch), d = 1.49 h= Falling Head, ft 2.58
c= Discharge Coefficient 0.6
Orifice Diameter (inch) Used, d =1.5 t= Time ( 36 hrs), sec.129,600
g= Accelleration, ft/sq.sec 32.2
a= Orifice Area (sf)
d= Orifice Diameter (inch)
T:\PROJECTS\2017 PROJECTS\17031 The Village At Granite - LGI\CALCS\BMP\Phase 1\17031-PH1-BMP Dry Detention.xls
printed 8/13/2018
page 1 of 2
Project: Village at Granite
Job No.: 17031
Location: Granite Quarry, NC
Sheet: 2 of 2
DPR ASSOCIATES, INC
SAND FILTER-1 DESIGN
Prepared By: RJ
Checked By: HN
Date: 10-17-17
Revised: 12-21-17
* BMP - SAND FILTER 6
Anti-Seep Collar Sizing
Outlet Pipe Size (I.D.) = 15 in
Outlet Pipe Size (O.D.) = 1.63 ft
L, Length of Outlet Pipe = 53 lf
Min. Flow Length = 61.0 ft Min. Flow Length = 115% of outlet pipe
Total Lengh of Collar offset = 8.0 ft
Number of anti-seep collars 2
Offset per collar 4.0 ft
Min. Outside dimension of each collar 5.60 ft
Designed collars 2 at 5.5' x 5.5'
T:\PROJECTS\2017 PROJECTS\17031 The Village At Granite - LGI\CALCS\BMP\Phase 1\17031-PH1-BMP Dry Detention.xls
printed 8/13/2018
page 2 of 2
Pond Report 25
Hydraflow Hydrographs Extension for AutoCAD® Civil 3D® 2018 by Autodesk, Inc. v12 Monday, 08 / 13 / 2018
Pond No. 5 - PH1 BMP 6 - DRY DETENTION
Pond Data
Contours -User-defined contour areas. Average end area method used for volume calculation. Begining Elevation = 753.00 ft
Stage / Storage Table
Stage (ft) Elevation (ft) Contour area (sqft) Incr. Storage (cuft) Total storage (cuft)
0.00 753.00 50 0 0
1.00 754.00 500 275 275
3.00 756.00 2,400 2,900 3,175
5.00 758.00 23,100 25,500 28,675
7.00 760.00 58,300 81,400 110,075
Culvert / Orifice Structures Weir Structures
[A] [B] [C] [PrfRsr] [A] [B] [C] [D]
Rise (in)= 15.00 1.50 6.00 0.00
Span (in)= 15.00 1.50 138.00 0.00
No. Barrels = 1 110
Invert El. (ft)= 753.00 753.00 756.50 0.00
Length (ft)= 53.00 0.50 0.50 0.00
Slope (%)= 0.56 0.00 0.00 n/a
N-Value = .013 .013 .013 n/a
Orifice Coeff.= 0.60 0.60 0.60 0.60
Multi-Stage = n/a Yes Yes No
Crest Len (ft)= 0.00 0.00 0.00 0.00
Crest El. (ft)= 0.00 0.00 0.00 0.00
Weir Coeff.= 3.33 3.33 3.33 3.33
Weir Type = --- --- --- ---
Multi-Stage = No No No No
Exfil.(in/hr)= 0.000 (by Contour)
TW Elev. (ft)= 0.00
Note: Culvert/Orifice outflows are analyzed under inlet (ic) and outlet (oc) control. Weir risers checked for orifice conditions (ic) and submergence (s).
0.00 2.00 4.00 6.00 8.00 10.00 12.00 14.00 16.00
Stage (ft)
0.00 753.00
2.00 755.00
4.00 757.00
6.00 759.00
8.00 761.00
Elev (ft)
Discharge (cfs)
Stage / Discharge
Total Q
DPR ASSOCIATES, INC
BMP OUTLET STRUCTURE
BOUYANCY CALCULATION
OUTLET STRUCTURE BOUYANCY CALCULATION NCDOT #840.04
BMP Number BMP #1 BMP #2 BMP #3 BMP #4 BMP #6
Structure Number 1-400 2-200 3-400 4-200 5-106
WEIGHT OF DISPLACED WATER BY STRUCTURE
Volume of riser:
Outlet Pipe Diameter (in) =18 36 36 24 15
Length (ft) =5.00 5.50 5.50 5.00 3.50
Width (ft) =3.67 5.00 5.00 3.67 2.25
Wall thickness (ft) = 0.50 0.50 0.50 0.50 0.50
Weir Elev (ft) =736.00 736.00 731.80 726.50 727.20
Invert Out (in) =728.36 728.35 724.33 719.45 720.40
Height of Riser to Weir (ft) = 7.64 7.65 7.47 7.05 6.80
Riser Volume (cu.ft) =140.07 210.37 205.42 129.25 53.55
Volume of base:
Length (ft) = 6.00 6.50 6.50 6.00 4.50
Width (ft) = 4.67 6.00 6.00 4.67 3.25
Hight (ft) = 0.67 0.67 0.67 0.67 0.67
Base Volume (cu.ft) = 18.76 26.00 26.00 18.67 9.75
Area Loss for outlet pipe opening (sf): 2.25 4.00 4.00 2.83 1.96
Volume Loss for outlet pipe opening (cu.ft): -3.98 -12.57 -12.57 -6.31 -3.01
Total Volume of Structure: 154.85 223.81 218.86 141.61 60.29
Weight of Water (lbs/cu.ft) = 62.4 62.4 62.4 62.4 62.4
Weight of Water Displaced (lbs)9,663 13,966 13,657 8,837 3,762
WEIGHT OF STRUCTURE
Volume of Base (cu ft) = 18.76 26.00 26.00 18.67 9.75
Volume of riser:
Outside area (sf) = 18.33 27.50 27.50 18.33 7.88
Inside area (sf) = 10.67 18.00 18.00 10.67 3.13
Net area (sf) = 7.67 9.50 9.50 7.67 4.75
Height of Riser to Weir (ft) = 7.64 7.65 7.47 7.05 6.80
Volume of Riser (cu ft) = 58.57 72.67 70.96 54.05 32.30
Area Loss for outlet pipe opening (sf): 2.25 4.00 4.00 2.83 1.96
Volume Loss for outlet pipe opening (cu.ft): -3.98 -12.57 -12.57 -6.31 -3.01
Net Volume of Riser (sf) = 54.60 60.11 58.40 47.74 29.29
Volume of Posts (cu.ft):
Weir Height (in) = 6.00 7.00 8.00 9.00 10.00
Volume of Posts (cu.ft) = 0.90 1.04 1.19 1.33 1.48
Volume of Top Slab (cu.ft):
Length (ft) = 6.00 6.50 6.50 6.00 4.50
Width (ft) = 4.67 6.00 6.00 4.67 3.25
Thickness (in) = 4.00 5.00 6.00 7.00 8.00
Volume of Top slab (cu.ft) = 9.33 16.25 19.50 16.33 9.75
Volume Loss for Opening for Frame/Cover (cu ft) = 1.22 1.53 1.83 2.14 2.44
Volume of Top slab (cu.ft) = 8.11 14.72 17.67 14.20 7.31
Weight of Concrete in Structure (lbs) = 12,355 15,280 15,488 12,291 7,174
Weight of Ring and Cover (lbs) = 230 231 232 233 234
Total Weight Structure (lbs) =12,585 15,511 15,720 12,524 7,408
Anchor Block:
Length (ft) = 6.00 6.50 6.50 6.00 4.50
Width (ft) = 4.67 6.00 6.00 4.67 3.25
Height (ft) =0.00 0.00 0.00 0.00 0.00
Anchor Block Volume (cu.ft) = 0.0 0.0 0.0 0.0 0.0
Weight of Water (lbs/cu.ft) = 62.4 62.4 62.4 62.4 62.4
Weight of Water Displaced by Anchor Block (lbs)0000 0
Weight of Anchor Block (lbs)0000 0
Not Required Not Required Not Required Not Required Not Required
NET BOUYANCY***
Weight of Water Displaced (lbs) 9,663 13,966 13,657 8,837 3,762
Total Weight Structure (lbs) = 12,585 15,511 15,720 12,524 7,408
Bouyancy (lbs) = 2,922 1,546 2,063 3,688 3,646
Safety Factor = 1.30 1.11 1.15 1.42 1.97
*** Includes anchor block, if needed
T:\PROJECTS\2017 PROJECTS\17031 The Village At Granite - LGI\CALCS\BMP\Phase 1\17031-PH1 BMP Anchor Block.xls printed 8/13/2018