Loading...
HomeMy WebLinkAboutNCG030317_Compliance Inspection Evaluation_20150713Directions to Facility: System Classifications: Primary ORC: Secondary ORC(s): On -Site Representative(s): Related Permits: Inspection Date: 07/13/2015 Primary Inspector: Darlene J Kucken Secondary Inspector(s): Certification: Phone: Entry Time: 01:OOPM Exit Time: 02:30PM Phone: Reason for Inspection: Routine Inspection Type: Compliance Evaluation Permit Inspection Type: Metal Fabrication Stormwater Discharge COC Facility Status: Compliant ❑ Not Compliant Question Areas: 0 Storm Water (See attachment summary) Page: 1 Compliance Inspection Report Permit: NCG030317 Effective: 11/01/12 Expiration: 10/31/17 Owner: -Geie e SOC: Effective: Expiration: Facility: Coleman Cable - Hayesville County: Clay 788 Tusquittee Rd Region: Asheville Hayesville NC 28904 •�� � 0LVP_ ll C04 3 A \ Contact Person: - r7 h i -w rsv Title: Phone: 704-389-8011 Directions to Facility: System Classifications: Primary ORC: Secondary ORC(s): On -Site Representative(s): Related Permits: Inspection Date: 07/13/2015 Primary Inspector: Darlene J Kucken Secondary Inspector(s): Certification: Phone: Entry Time: 01:OOPM Exit Time: 02:30PM Phone: Reason for Inspection: Routine Inspection Type: Compliance Evaluation Permit Inspection Type: Metal Fabrication Stormwater Discharge COC Facility Status: Compliant ❑ Not Compliant Question Areas: 0 Storm Water (See attachment summary) Page: 1 Permit: NCG030317 Owner - Facility: Coleman Cable Inspection Date: 07/13/2015 Inspection Type : Compliance Evaluation Reason for Visit: Routine Inspection Summary: 1 This inspection was conducted to assess the results of the Tier I sampling and request for no exposure (NE). The facility was previously inspected in January 2014 in response to a NE request and was found to be non compliant and the NE request was not granted based on site coonditions 2. A recycling program has been instituted at the facility, as well as some housekeeping practices. These changes have resulted in lower Zn levels (2014 = .080 mg/L and 2015 = 045 mg/L) and lower Cu levels (2014 =.048 mg/L and 2015 = .020 mg/L). Current benchmarks for these metals are: Zn = .067 mg/L and Cu = .007 mg/L. Upon permit renewal, these benchmarks will increase to Zn = 126 mg/L and Cu = 010 mg/L. 3 The facility appears to not exceed the Zn benchmark, but is above the benchmark for Cu. Given that the facility has copper on site for processing, there appears to be a need for further investigation as to the source of the copper. 4 There are still two large uncovered dumpsters that now contain primarily waste that can not be recycled. These uncovered dumpsters constitute an exposure. Covering or placing the dumpsters under cover would remove this exposure. 5. The new pallets stored on site are not considered to be an exposure; however, the used pallets on site are an exposure. Storing used pallets under cover would eliminate this exposure. 6. The previously noted floor drains were inspected and determined to be in the location of a removed restroom. These drains discharge to a municipal wastewater system. 7. The facility will need to cover and/or remove the two dumpsters and the used pallets to be considered for a no exposure permit Additional effort may be needed to investigate the source of Cu to assure smaple values are at or below benchmark levels. Semi-annual analytical monitoring should be continued Page: 2 Permit: NCG030317 Owner - Facility: Coleman Cable Inspection Date: 07/13/2015 Inspection Type : Compliance Evaluation Reason for Visit: Routine Stormwater Pollution Prevention Plan Yes No NA NE Does the site have a Stormwater Pollution Prevention Plan? N ❑ ❑ ❑ # Does the Plan include a General Location (USGS) map? E ❑ ❑ ❑ # Does the Plan include a "Narrative Description of Practices"? 0 ❑ ❑ ❑ # Does the Plan include a detailed site map including outfall locations and drainage areas? E ❑ ❑ ❑ # Does the Plan include a list of significant spills occurring during the past 3 years? ❑ ❑ N ❑ # Has the facility evaluated feasible alternatives to current practices? 0 ❑ ❑ ❑ # Does the facility provide all necessary secondary containment? 0 ❑ ❑ ❑ # Does the Plan include a BMP summary? ❑ ❑ ❑ # Does the Plan include a Spill Prevention and Response Plan (SPRP)? ❑ ❑ ❑ # Does the Plan include a Preventative Maintenance and Good Housekeeping Plan? ❑ ❑ ❑ # Does the facility provide and document Employee Training? E ❑ ❑ ❑ # Does the Plan include a list of Responsible Party(s)? E ❑ ❑ ❑ # Is the Plan reviewed and updated annually? 0 ❑ ❑ ❑ # Does the Plan include a Stormwater Facility Inspection Program? E ❑ ❑ ❑ Has the Stormwater Pollution Prevention Plan been implemented? E ❑ ❑ ❑ Comment Qualitative Monitoring Yes No NA NE Has the facility conducted its Qualitative Monitoring semi-annually? E ❑ ❑ ❑ Comment: Analytical Monitoring Yes No NA NE Has the facility conducted its Analytical monitoring? N 1:111 ❑ # Has the facility conducted its Analytical monitoring from Vehicle Maintenance areas? ❑ ❑ ■ ❑ Comment: Permit and Outfalls Yes No NA NE # Is a copy of the Permit and the Certificate of Coverage available at the site? ❑ ❑ ❑ # Were all outfalls observed during the inspection? ❑ ❑ ❑ # If the facility has representative outfall status, is it properly documented by the Division? ❑ ❑ 0 ❑ # Has the facility evaluated all illicit (non stormwater) discharges? ❑ ❑ 0 ❑ Comment: Page: 3