Loading...
HomeMy WebLinkAboutWQCSD0042_Inspection_20180823DocuSign Envelope ID: 97E185A5-1778-4589-9814-OA39F1C32759 Comoliance Insoection Resort Permit: WQCSD0042 Effective: 03/01/00 Expiration: Owner: Town of Rhodhiss SOC: Effective: Expiration: Facility: Rhodhiss Collection System County: Burke Region: Asheville Contact Person: Chris Wagoner Title: Phone: 828-396-8400 Directions to Facility: System Classifications: CS1, Primary ORC: Secondary ORC(s): On -Site Representative(s): Related Permits: Inspection Date: 08/15/2018 EntryTime: 10:OOAM Primary Inspector: Linda S Wiggs EW Secondary Inspector(s): Certification: Phone: Exit Time: 02:30PM Phone: 828-296-4500 Ext.4653 Reason for Inspection: Routine Inspection Type: Collection System Inspect Non Sampling Permit Inspection Type: Deemed permitted collection system management and operation Facility Status: ❑ Compliant Not Compliant Question Areas: Miscellaneous Questions Performance Standards Operation & Maint Reqmts Records Monitoring & Rpting Reqmts Inspections Pump Station Manhole Lines (See attachment summary) Page: 1 DocuSign Envelope ID: 97E185A5-1778-4569-9814-OA39F1C32759 Permit: WQCSD0042 Owner - Facility: Town of Rhodhiss Inspection Date: 08/15/2018 Inspection Type : Collection System Inspect Non Sampling Reason for Visit: Routine Inspection Summary: The inspector, Linda Wiggs, met with the new Town Manager Chris Wagoner and Will Dennis Public Works Director. The Town is not meeting all the 15A NCAC 02T.04O3 requirements. This has been an issue for the Town in the past, if these requirements cannot be consistently met requiring an Individual Collection System Permit may be warranted. Given the proximity to the lake and past issues, it is essential that proper reporting and documentation take place. Refer to question section for details. Page: 2 DocuSign Envelope ID: 97E185A5-1778-4589-9814-OA39F1C32759 Permit: WQCSDO042 Owner - Facility: Town of Rhodhiss Inspection Date: 08/15/2018 Inspection Type : Collection System Inspect Non Sampling Reason for Visit: Routine Performance Standards Yes No NA NE Is Public Education Program for grease established and documented? 0 ❑ ❑ ❑ What educational tools are used? Newsletter, website. Suggest adding flushables langauge. Is Sewer Use Ordinance/Legal Authority available? 0 ❑ ❑ ❑ Does it appear that the Sewer Use Ordinance is enforced? ❑ ❑ ❑ 0 Is Grease Trap Ordinance available? ❑ ❑ ❑ Is Septic Tank Ordinance available (as applicable, i.e. annexation) ❑ ❑ ❑ List enforcement actions by permittee, if any, in the last 12 months None. Has an acceptable Capital Improvement Plan (CIP) been implemented? ❑ ❑ ❑ Does CIP address short term needs and long term \"master plan\" concepts? ❑ ❑ ❑ Does CIP cover three to five year period? ❑ ❑ ❑ Does CIP include Goal Statement? ❑ ❑ ❑ Does CIP include description of project area? ❑ ❑ ❑ Does CIP include description of existing facilities? ❑ ❑ ❑ Does CIP include known deficiencies? ❑ ❑ ❑ Does CIP include forecasted future needs? ❑ ❑ ❑ Is CIP designated only for wastewater collection and treatment? ❑ ❑ ❑ Approximate capital improvement budget for collection system? Total annual revenue for wastewater collection and treatment? CIP Comments West Consultants assists Rhodhiss with CIP, Asset Mgt. THE TOWN IS CURRENTLY ENGAGED IN A SEWERLINE REHAB/REPLACEMENT PROJECT; ANTICIPATING I&I REDUCTION. Is system free of known points of bypass? ❑ ❑ ❑ If no, describe type of bypass and location A questionable line was observed in the Catawba St. PS, this line needs to be evaluated to make sure it is not a bypass/overflow line. Is a 24-hour notification sign posted at ALL pump stations? ❑ ❑ ❑ # Does the sign include: Instructions for notification? ❑ ❑ ❑ Pump station identifier? ❑ ❑ ❑ 24-hour contact numbers ❑ ❑ ❑ If no, list deficient pump stations The three PS visited had signage. # Do ALL pump stations have an "auto polling" feature/SCADA? ❑ ❑ ❑ Number of pump stations 5 Page: 3 DocuSign Envelope ID: 97E185A5-1778-4569-9814-OA39F1C32759 Permit: WQCSDO042 Owner - Facility: Town of Rhodhiss Inspection Date: 08/15/2018 Inspection Type : Collection System Inspect Non Sampling Reason for Visit: Routine Number of pump stations that have SCADA Number of pump stations that have simple telemetry Number of pump stations that have only audible and visual alarms Number of pump stations that do not meet permit requirements # Does the permittee have a root control program? # If yes, date implemented? Describe: Town has a jetter. Comment: Refer to PS section. Inspections Are maintenance records for sewer lines available? Are records available that document pump station inspections? Are SCADA or telemetry equipped pump stations inspected at least once a week? Are non-SCADA/telemetry equipped pump stations inspected every day? Are records available that document citizen complaints? # Do you have a system to conduct an annual observation of entire system? 5 ❑❑■❑ Yes No NA NE ❑■❑❑ ■❑❑❑ # Has there been an observation of remote areas in the last year? ❑ ❑ ❑ Are records available that document inspections of high-priority lines? ❑ ❑ ❑ Has there been visual inspections of high-priority lines in last six months? 0 ❑ ❑ ❑ Comment: Rhodhiss staff stated thev inspect the PS and view the hiah-Drioritv (force main) line under the bridge from the Caldwell PS weekly. However, they are not documenting these inspections. This is a small system and many repairs are under construction, so observation of the entire system and remote areas is likely taking place. Documentation is lacking. Not meeting all 15A NCAC 02T.0403 requirements. Operation & Maintenance Requirements Are all log books available? Does supervisor review all log books on a regular basis? Does the supervisor have plans to address documented short-term problem areas? What is the schedule for reviewing inspection, maintenance, & operations logs and problem areas? Construction under way of line replacement. Are maintenance records for equipment available? Is a schedule maintained for testing emergency/standby equipment? What is the schedule for testing emergency/standby equipment? Do pump station logs include: Inside and outside cleaning and debris removal? Inspecting and exercising all valves? Inspecting and lubricating pumps and other equipment? Inspecting alarms, telemetry and auxiliary equipment? Yes No NA NE ❑■❑❑ ❑ ❑ ❑ ❑ ❑ ❑ Need to document. ❑■❑❑ ❑■❑❑ ❑■❑❑ ❑■❑❑ Page: 4 DocuSign Envelope ID: 97E185A5-1778-4589-9814-OA39F1C32759 Permit: WQCSDO042 Owner - Facility: Town of Rhodhiss Inspection Date: 08/15/2018 Inspection Type : Collection System Inspect Non Sampling Reason for Visit: Routine Is there at least one spare pump for each pump station w/o pump reliability? ❑ 0 ❑ ❑ Are maintenance records for right-of-ways available? ❑ 0 ❑ ❑ Are right-of-ways currently accessible in the event of an emergency? ❑ ❑ ❑ Are system cleaning records available? ❑ ❑ ❑ Has at least 10% of system been cleaned annually? ❑ ❑ ❑ What areas are scheduled for cleaning in the next 12 months? Pump stations and capacity STAFF STATED LINES ARE BEING CLEANED IN CONCERT WITH CONSTRUCTION ACTIVITIES. If no, what percent is complete? Is a Spill Response Action Plan available? ❑ ❑ ❑ Does the plan include: The map will be updated once construction activities are complete. 24-hour contact numbers ❑ ❑ ❑ Response time ❑ ❑ ❑ Equipment list and spare parts inventory ❑ ❑ ❑ Access to cleaning equipment ❑ ❑ ❑ Access to construction crews, contractors, and/or engineers ❑ ❑ ❑ Source of emergency funds ❑ ❑ ❑ Site sanitation and cleanup materials ❑ ❑ ❑ Post-overflow/spill assessment ❑ ❑ ❑ Is a Spill Response Action Plan available for all personnel? ❑ ❑ ❑ Is the spare parts inventory adequate? ❑ 0 ❑ ❑ Comment: A Spill/Overflow Response Plan is required to be developed and implemented. Records Yes No NA NE Are adequate records of all SSOs, spills and complaints available? ❑ ❑ ❑ Are records of SSOs that are under the reportable threshold available? ❑ ❑ ❑ Do spill records indicate repeated overflows (2 or more in 12 months) at same location? ❑ ❑ ❑ If yes, is there a corrective action plan? ❑ ❑ ❑ Is a map of the system available? ❑ ❑ ❑ Does the map include: Pipe sizes 0 ❑ ❑ ❑ Pipe materials ❑ ❑ ❑ Pipe location ❑ ❑ ❑ Flow direction ❑ ❑ ❑ Approximate pipe age ❑ ❑ ❑ Number of service taps ❑ ❑ ❑ Pump stations and capacity ❑ ❑ ❑ If no, what percent is complete? List any modifications and extensions that need to be added to the map The map will be updated once construction activities are complete. Page: 5 DocuSign Envelope ID: 97E185A5-1778-4569-9814-OA39F1C32759 Permit: WQCSDO042 Owner - Facility: Town of Rhodhiss Inspection Date: 08/15/2018 Inspection Type : Collection System Inspect Non Sampling Reason for Visit: Routine # Does the permittee have a copy of their permit? ❑ ❑ 0 ❑ Comment: Documentation is required. An Individual Permit may be warranted, 15A NCAC 02T.0403 (c). Monitoring and Reporting Requirements Yes No NA NE Are copies of required press releases and distribution lists available? ❑ 0 ❑ ❑ Are public notices and proof of publication available? ❑ 0 1:11:1 # Is an annual report being prepared in accordance with G.S. 143-215.1 C? ❑ ❑ 0 ❑ # Is permittee compliant with all compliance schedules in the permits? ❑ ❑ 0 ❑ If no, which one(s)? Comment: Overflow reporting requirements were discussed. UPSTR CALDWELL PS - Manhole Yes No NA NE Is manhole accessible? 0 ❑ ❑ ❑ # Is manhole cover/vent above grade? ❑ 0 ❑ ❑ Is the manhole free of visible signs of overflow? 0 ❑ ❑ ❑ Is the manhole free of sinkholes and depressions? ❑ ❑ ❑ Is manhole cover present? 0 ❑ ❑ ❑ # Is manhole properly seated? ❑ ❑ ❑ # Is manhole in good condition? ❑ ❑ ❑ # Is invert in good condition? ❑ ❑ ❑ Is line free-flowing and unrestricted in manhole? ❑ 0 ❑ ❑ Is manhole free of excessive amounts of grease? ❑ ❑ ❑ Is manhole free of excessive roots? ❑ ❑ ❑ Is manhole free of excessive sand? ❑ ❑ ❑ Is manhole's extended vent screened? ❑ ❑ ❑ Are vents free of submergence? ❑ ❑ ❑ Are manholes free of bypass structures or pipes? 0 ❑ ❑ ❑ Comment: A root wad was present, it was removed by staff. MH had evidence of surging. #157 WALNUT - Manhole Yes No NA NE Is manhole accessible? ❑ ❑ ❑ # Is manhole cover/vent above grade? ❑ ❑ ❑ Is the manhole free of visible signs of overflow? ❑ ❑ ❑ Is the manhole free of sinkholes and depressions? ❑ ❑ ❑ Is manhole cover present? 0 ❑ ❑ ❑ Page: 6 DocuSign Envelope ID: 97E185A5-1778-4589-9814-OA39F1C32759 Permit: WQCSDO042 Owner - Facility: Town of Rhodhiss Inspection Date: 08/15/2018 Inspection Type : Collection System Inspect Non Sampling Reason for Visit: Routine # Is manhole properly seated? 0 ❑ ❑ ❑ # Is manhole in good condition? 0 ❑ ❑ ❑ # Is invert in good condition? ❑ 0 ❑ ❑ Is line free-flowing and unrestricted in manhole? ❑ ❑ ❑ Is manhole free of excessive amounts of grease? ❑ ❑ ❑ Is manhole free of excessive roots? 0 ❑ ❑ ❑ Is manhole free of excessive sand? ❑ ❑ ❑ Is manhole's extended vent screened? ❑ ❑ ❑ Are vents free of submergence? ❑ ❑ ❑ Are manholes free of bypass structures or pipes? ❑ ❑ ❑ Comment: Invert is crumbling and needs to be repaired #14 DOLLAR GENERAL - Manhole Yes No NA NE Is manhole accessible? ❑ ❑ ❑ # Is manhole cover/vent above grade? ❑ ❑ ❑ Is the manhole free of visible signs of overflow? ❑ ❑ ❑ Is the manhole free of sinkholes and depressions? ❑ ❑ ❑ Is manhole cover present? 0 ❑ ❑ ❑ # Is manhole properly seated? ❑ ❑ ❑ # Is manhole in good condition? ❑ ❑ ❑ # Is invert in good condition? ❑ ❑ ❑ Is line free-flowing and unrestricted in manhole? ❑ ❑ ❑ Is manhole free of excessive amounts of grease? ❑ ❑ ❑ Is manhole free of excessive roots? 0 ❑ ❑ ❑ Is manhole free of excessive sand? ❑ ❑ ❑ Is manhole's extended vent screened? ❑ ❑ ❑ Are vents free of submergence? ❑ ❑ ❑ Are manholes free of bypass structures or pipes? 0 ❑ ❑ ❑ Comment: MH receives 2 force mains. Town uses a cap to prevent stormwater inflow. The top of the MH is degraded and will allow matter to fall into the system. #2 CATAWBA ST. PS - Pump Station Yes No NA NE Pump station type Duplex Are pump station logs available? ❑ ❑ ❑ Is it accessible in all weather conditions? ❑ ❑ ❑ # Is general housekeeping acceptable? ❑ ❑ ❑ Page: 7 DocuSign Envelope ID: 97E185A5-1778-4589-9814-OA39F1C32759 Permit: WQCSDO042 Owner - Facility: Town of Rhodhiss Inspection Date: 08/15/2018 Inspection Type : Collection System Inspect Non Sampling Reason for Visit: Routine Are all pumps present? 0 ❑ ❑ ❑ Are all pumps operable? 0 ❑ ❑ ❑ Are wet wells free of excessive debris? 0 ❑ ❑ ❑ Are upstream manholes free of excessive debris/signs of overflow? ❑ ❑ ❑ Are floats/controls for pumps/alarms operable? ❑ ❑ ❑ Is "auto polling" feature/SCADA present? ❑ ❑ ❑ Is "auto polling" feature/SCADA operational? ❑ ❑ ❑ Is simple telemetry present? ❑ ❑ ❑ Is simple telemetry operational? ❑ ❑ ❑ Are audio and visual alarms present? ❑ ❑ ❑ Are audio and visual alarms operable? ❑ ❑ ❑ Is the Pump station inspected as required? ❑ ❑ ❑ Are backflow devices in place? ❑ ❑ ❑ Are backflow devices operable? ❑ ❑ ❑ Are air relief valves in place? ❑ ❑ ❑ Are air relief valves operable? ❑ ❑ ❑ # Is an emergency generator available? ❑ ❑ ❑ Can the emergency generator run the pumps? ❑ ❑ ❑ Is the pump station equipped for quick hook-up? ❑ ❑ ❑ Is the generator operable? ❑ ❑ ❑ # Is fuel in tank and sufficient? ❑ ❑ ❑ Is the generator inspected according to their schedule? ❑ ❑ ❑ Is a 24-hour notification sign posted? 0 ❑ ❑ ❑ Does it include: Instructions for notification? 0 ❑ ❑ ❑ Pump station identifier? 0 ❑ ❑ ❑ Emergency phone number ❑ ❑ ❑ Is public access limited? ❑ ❑ ❑ Is pump station free of overflow piping? ❑ ❑ ❑ Is the pump station free of signs of overflow? ❑ ❑ ❑ Are run times comparable for multiple pumps? Comment: Not meeting 15A NCAC 02T.0403 documentation requirements. A line near the top of the wet well needs evaluation to verify it is not an overflow/bypass line. A high water line with grease and debris was observed up to this line. Pump 2 dial needs to be checked, it did not rotate during test: staff stated it does register on SCADA. Staff stated that Bumqarner Septic pumps clean the Towns PS 2/year. #1 CALDWELL PS - Page: 8 DocuSign Envelope ID: 97E185A5-1778-4569-9814-OA39F1C32759 Permit: WQCSD0042 Owner - Facility: Town of Rhodhiss Inspection Date: 08/15/2018 Inspection Type : Collection System Inspect Non Sampling Reason for Visit: Routine Pump Station Yes No NA NE Pump station type Duplex Are pump station logs available? ❑ 0 ❑ ❑ Is it accessible in all weather conditions? 0 ❑ ❑ ❑ # Is general housekeeping acceptable? 0 ❑ ❑ ❑ Are all pumps present? 0 ❑ ❑ ❑ Are all pumps operable? 0 ❑ ❑ ❑ Are wet wells free of excessive debris? 0 ❑ ❑ ❑ Are upstream manholes free of excessive debris/signs of overflow? ❑ 0 ❑ ❑ Are floats/controls for pumps/alarms operable? ❑ ❑ ❑ Is "auto polling" feature/SCADA present? ❑ ❑ ❑ Is "auto polling" feature/SCADA operational? ❑ ❑ ❑ Is simple telemetry present? ❑ ❑ ❑ Is simple telemetry operational? ❑ ❑ ❑ Are audio and visual alarms present? ❑ ❑ ❑ Are audio and visual alarms operable? ❑ ❑ ❑ Is the Pump station inspected as required? ❑ ❑ ❑ Are backflow devices in place? ❑ ❑ ❑ Are backflow devices operable? ❑ ❑ ❑ Are air relief valves in place? ❑ ❑ ❑ Are air relief valves operable? ❑ ❑ ❑ # Is an emergency generator available? ❑ ❑ ❑ Can the emergency generator run the pumps? ❑ ❑ ❑ Is the pump station equipped for quick hook-up? ❑ ❑ ❑ Is the generator operable? ❑ ❑ ❑ # Is fuel in tank and sufficient? ❑ ❑ ❑ 0 Is the generator inspected according to their schedule? ❑ ❑ ❑ Is a 24-hour notification sign posted? ❑ ❑ ❑ Does it include: Instructions for notification? ❑ ❑ ❑ Pump station identifier? ❑ ❑ ❑ Emergency phone number ❑ ❑ ❑ Is public access limited? ❑ ❑ ❑ Is pump station free of overflow piping? ❑ ❑ ❑ Is the pump station free of signs of overflow? ❑ ❑ ❑ Are run times comparable for multiple pumps? Page: 9 DocuSign Envelope ID: 97E185A5-1778-4589-9814-OA39F1C32759 Permit: WQCSDO042 Owner - Facility: Town of Rhodhiss Inspection Date: 08/15/2018 Inspection Type : Collection System Inspect Non Sampling Reason for Visit: Routine Comment: Not meeting 15A NCAC 02T.0403 documentation requirements. #86 UPSTR CTB PS - Manhole Is manhole accessible? # Is manhole cover/vent above grade? Is the manhole free of visible signs of overflow? Is the manhole free of sinkholes and depressions? Is manhole cover present? # Is manhole properly seated? # Is manhole in good condition? # Is invert in good condition? Is line free-flowing and unrestricted in manhole? Is manhole free of excessive amounts of grease? Is manhole free of excessive roots? Is manhole free of excessive sand? Is manhole's extended vent screened? Are vents free of submergence? Are manholes free of bypass structures or pipes? Comment: Yes No NA NE ■❑❑❑ ❑ ❑ ❑ ❑ ❑ ❑ ■❑❑❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ Page: 10