Loading...
HomeMy WebLinkAboutNC0022209_Compliance Evaluation Inspection_20180814 4447 NORTH CAROLINA ROY COOPER Environmmero&Qn°8ty Governor MICHAEL S. REGAN Secretary LINDA CULPEPPER ) RECD!V E.D,'? :"\`r4ik Interim Director August 14, 2018 AUG 2 2 2018 Water Resources Mr. Otto Muha, Terminal Superintendent Permitting Section Motiva Enterprises, LLC 101 South Chimney Rock Road Greensboro, NC 27409 SUBJECT: Compliance Evaluation Inspection Motiva Enterprises, LLC —Greensboro Terminal NPDES Permit No. NC0022209 Guilford County Dear Mr. Muha: On August 9, 2018, Jenny Graznak, of this office, met with you and Doug Witten to perform a Compliance Evaluation Inspection on Motiva Enterprises, LLC — Greensboro Terminal stormwater/wastewater treatment system. This type of inspection consists of two basic parts: an in-office file review and an on-site inspection of the treatment facility. The attached EPA inspection form notes the areas that were evaluated for this inspection. The findings and observations are outlined below: I. Permit The NPDES permit became effective January 1, 2017 and expires August 31, 2021. The facility had.a copy of the current permit available during the inspection. The treatment structures seen during the inspection match those listed in the permit. • II. Self-Monitoring Program A review of the monthly discharge monitoring reports (DMRs) for the period July 2017 through June 2018 showed that the facility complied with all permit limits. Regarding the permit monitoring requirements, it was noted that all sampling was performed per the frequencies specified in the permit. All laboratory analysis is performed by Research & Analytical Laboratories, Inc. except Acute Whole Effluent Toxicity Testing, which is performed by Environmental Testing Solutions, Inc. Mr.Witten collects the monthly and/or quarterly grab samples, and a representative from the laboratory picks them up at the site. Ill. Records/Reports Mr. Witten fills out a Retention Pond Draining Report for every discharge event. Chain of custody forms and lab data sheets are in good order. All the required monitoring was D Q North Carolina Department of Environmental Quality I Division of Water Resources Winston-Salem Regional Office 1450 W.Hanes Mill Road,Suite 300 I Winston-Salem,North Carolina 27105 336-776-9800 r i Motive Enterprises,LLC—Greensboro Terminal,August 14,2018 performed per the frequencies specified in the NPDES permit. Ms. Graznak noted no data transcription discrepancies from lab sheets to DMRs in her documentation review. IV. Flow Measurement The permit requires episodic flow monitoring. Flow is measured using a totalizing flow meter on the effluent pipe. The discharge is controlled manually by a locked release valve. The flow meter was calibrated on December 4, 2017. Flow is recorded on the Retention Pond Draining Report. V. Operations and Maintenance The facility appeared to be well operated and maintained. No issues were noted during the inspection. VI. Facility Site Review The truck loading area drains to a concrete holding pit and then is pumped to an 8,000- gallon above ground storage tank with a hydrocarbon detector. If no hydrocarbon is detected, the water is transferred to the secondary containment area surrounding the aboveground storage tanks. From there, it drains to the settling pond. VII. Effluent/Receivinq Waters The system discharges to a rip rap lined ditch just outside of the perimeter fence. The effluent eventually reaches an unnamed tributary of Long Branch, class Water Supply IV Waters in the Cape Fear River Basin. No effluent was being discharged on the day of the inspection. If you have any questions regarding the inspection or this report, please contact Jenny Graznak or me at (336) 776-9800. • Sincerely, Sherri V. Knight, P.E. Regional Supervisor Water Quality Regional Operations Division of Water Resources Attachments: EPA Water Compliance Inspection Report cc: Central Files WSRO NPDES Unit 2 i - United States Environmental Protection Agency Form Approved. E PA Washington,D C 20460 OMB No.2040-0057 Water Compliance Inspection Report Approval expires 8-31-98 Section A.National Data System Coding(i.e.,PCS) Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type 1 E 2 LI 3 1 NC0022209 111 12 1 18/08/09 117 18 LI 19 1 c I 201 I 21111111 111111111111111111 I I I1111 1111111II I I P6 Inspection Work Days Facility Self-Monitoring Evaluation Rating B1 QA Reserved 67 I 1 70 LI 71 Ii 72 I _JN I 73[ I 174 751 1 1 1 1 1 1 180 Section B:Facility Data L Name and Location of Facility Inspected(For Industrial Users discharging to POTW,also include Entry Time/Date Permit Effective Date POTW name and NPDES permit Number) 08 OOAM 18/08/09 17/01/01 Greensboro Terminal Exit Time/Date Permit Expiration Date 101 S Chimney Rock Rd 09 30AM 18/08/09 21/08/31 Greensboro NC 27409 Name(s)of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) Other Facility Data /// Not Required/ORC/919-807-6353/ Name,Address of Responsible Official/Title/Phone and Fax Number Contacted Sam Baker,101 S Chimney Rock Rd Greensboro NC 274099661//336-299-0331/3362924494 No Section C.Areas Evaluated During Inspection(Check only those areas evaluated) • Permit • Flow Measurement • Records/Reports MI Self-Monitoring Program • Facility Site Review MI Effluent/Receiving Waters Section D:Summary of Finding/Comments(Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s)and Signature(s)of Inspector(s) Agency/Office/Phone and Fax Numbers P Date Jennifer F Graznakckeyoix.f.4.e WSRO WQ//336-771-5000/ r g/I Z VC 8 Signature nagement Q A Reviewer Agency/Office/Phone and Fax Numbers Date /4" 2.) EPA Form 3560-3(Rev 9-94)Previous editions are obsolete. Page# 1 NPDES yr/mo/day Inspection Type (Cont.) 1 31 NC0022209 I11 12[ 18/08/09 117 18 LI Section D.Summary of Finding/Comments(Attach additional sheets of narrative and checklists as necessary) I. Permit The NPDES permit became effective January 1, 2017 and expires August 31, 2021.The facility had a copy of the current permit available during the inspection.The treatment structures seen during the inspection match those listed in the permit. II. Self-Monitoring Program A review of the monthly discharge monitoring reports(DMRs) for the period July 2017 through June 2018 showed that the facility complied with all permit limits. Regarding the permit monitoring requirements, it was noted that all sampling was performed per the frequencies specified in the permit. All laboratory analysis is performed by Research &Analytical Laboratories, Inc. except Acute Whole Effluent Toxicity Testing,which is performed by Environmental Testing Solutions, Inc. Mr.Witten collects the monthly and/or quarterly grab samples, and a representative from the laboratory picks them up at the site. III. Records/Reports Mr. Witten fills out a Retention Pond Draining Report for every discharge event. Chain of custody forms and lab data sheets are in good order.All the required monitoring was performed per the frequencies specified in the NPDES permit. Ms. Graznak noted no data transcription discrepancies from lab sheets to DMRs in her documentation review. IV. Flow Measurement The permit requires episodic flow monitoring. Flow is measured using a totalizing flow meter on the effluent pipe. The discharge is controlled manually by a locked release valve. The flow meter was calibrated on December 4, 2017. Flow is recorded on the Retention Pond Draining Report. V. Operations and Maintenance The facility appeared to be well operated and maintained. No issues were noted during the inspection. VI. Facility Site Review The truck loading area drains to a concrete holding pit and then is pumped to an 8,000-gallon above ground storage tank with a hydrocarbon detector. If no hydrocarbon is detected,the water is transferred to the secondary containment area surrounding the aboveground storage tanks. From there, it drains to the settling pond. VII. Effluent/Receiving Waters The system discharges to a rip rap lined ditch just outside of the perimeter fence. The effluent eventually reaches an unnamed tributary of Long Branch, class Water Supply IV Waters in the Cape Fear River Basin. No effluent was being discharged on the day of the inspection. Page# 2 ' Permit: NC0022209 Owner-Facility: Greensboro Terminal Inspection Date: 08/09/2018 Inspection Type: Compliance Evaluation Permit Yes No NA NE (If the present permit expires in 6 months or less). Has the permittee submitted a new 0 0 IN 0 application? Is the facility as described in the permit? • 0 0 0 #Are there any special conditions for the permit? 0 ❑ • 0 Is access to the plant site restricted to the general public? • 0 0 0 Is the inspector granted access to all areas for inspection? • 0 0 0 Comment: The facility had a copy of the current permit available during the inspection Flow Measurement-Effluent Yes No NA NE #Is flow meter used for reporting? • 0 0 0 Is flow meter calibrated annually? • 0 0 0 Is the flow meter operational? • 0 0 0 (If units are separated) Does the chart recorder match the flow meter? 0 II 0 0 Comment: Flow is measured with a totalizing meter on the effluent pipe. Effluent Pipe Yes No NA NE Is right of way to the outfall properly maintained? • ❑ 0 0 Are the receiving water free of foam other than trace amounts and other debris? 0 0 0 U If effluent (diffuser pipes are required) are they operating properly? 0 0 MI 0 Comment: The system was not discharging on the day of the inspection so no effluent was observed. Page# 3