HomeMy WebLinkAboutNC0022209_Compliance Evaluation Inspection_20180814 4447
NORTH CAROLINA
ROY COOPER Environmmero&Qn°8ty
Governor
MICHAEL S. REGAN
Secretary
LINDA CULPEPPER )
RECD!V E.D,'? :"\`r4ik
Interim Director
August 14, 2018 AUG 2 2 2018
Water Resources
Mr. Otto Muha, Terminal Superintendent Permitting Section
Motiva Enterprises, LLC
101 South Chimney Rock Road
Greensboro, NC 27409
SUBJECT: Compliance Evaluation Inspection
Motiva Enterprises, LLC —Greensboro Terminal
NPDES Permit No. NC0022209
Guilford County
Dear Mr. Muha:
On August 9, 2018, Jenny Graznak, of this office, met with you and Doug Witten to
perform a Compliance Evaluation Inspection on Motiva Enterprises, LLC — Greensboro
Terminal stormwater/wastewater treatment system. This type of inspection consists of two
basic parts: an in-office file review and an on-site inspection of the treatment facility. The
attached EPA inspection form notes the areas that were evaluated for this inspection. The
findings and observations are outlined below:
I. Permit
The NPDES permit became effective January 1, 2017 and expires August 31, 2021.
The facility had.a copy of the current permit available during the inspection. The treatment
structures seen during the inspection match those listed in the permit.
•
II. Self-Monitoring Program
A review of the monthly discharge monitoring reports (DMRs) for the period July 2017
through June 2018 showed that the facility complied with all permit limits. Regarding the
permit monitoring requirements, it was noted that all sampling was performed per the
frequencies specified in the permit. All laboratory analysis is performed by Research &
Analytical Laboratories, Inc. except Acute Whole Effluent Toxicity Testing, which is performed
by Environmental Testing Solutions, Inc. Mr.Witten collects the monthly and/or quarterly grab
samples, and a representative from the laboratory picks them up at the site.
Ill. Records/Reports
Mr. Witten fills out a Retention Pond Draining Report for every discharge event. Chain
of custody forms and lab data sheets are in good order. All the required monitoring was
D Q
North Carolina Department of Environmental Quality I Division of Water Resources
Winston-Salem Regional Office 1450 W.Hanes Mill Road,Suite 300 I Winston-Salem,North Carolina 27105
336-776-9800
r i
Motive Enterprises,LLC—Greensboro Terminal,August 14,2018
performed per the frequencies specified in the NPDES permit. Ms. Graznak noted no data
transcription discrepancies from lab sheets to DMRs in her documentation review.
IV. Flow Measurement
The permit requires episodic flow monitoring. Flow is measured using a totalizing flow
meter on the effluent pipe. The discharge is controlled manually by a locked release valve.
The flow meter was calibrated on December 4, 2017. Flow is recorded on the Retention Pond
Draining Report.
V. Operations and Maintenance
The facility appeared to be well operated and maintained. No issues were noted during
the inspection.
VI. Facility Site Review
The truck loading area drains to a concrete holding pit and then is pumped to an 8,000-
gallon above ground storage tank with a hydrocarbon detector. If no hydrocarbon is detected,
the water is transferred to the secondary containment area surrounding the aboveground
storage tanks. From there, it drains to the settling pond.
VII. Effluent/Receivinq Waters
The system discharges to a rip rap lined ditch just outside of the perimeter fence. The
effluent eventually reaches an unnamed tributary of Long Branch, class Water Supply IV
Waters in the Cape Fear River Basin. No effluent was being discharged on the day of the
inspection.
If you have any questions regarding the inspection or this report, please contact Jenny
Graznak or me at (336) 776-9800.
•
Sincerely,
Sherri V. Knight, P.E.
Regional Supervisor
Water Quality Regional Operations
Division of Water Resources
Attachments: EPA Water Compliance Inspection Report
cc: Central Files
WSRO
NPDES Unit
2
i -
United States Environmental Protection Agency Form Approved.
E PA Washington,D C 20460 OMB No.2040-0057
Water Compliance Inspection Report Approval expires 8-31-98
Section A.National Data System Coding(i.e.,PCS)
Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type
1 E 2 LI 3 1 NC0022209 111 12 1 18/08/09 117 18 LI 19 1 c I 201 I
21111111 111111111111111111 I I I1111 1111111II I I P6
Inspection Work Days Facility Self-Monitoring Evaluation Rating B1 QA Reserved
67 I 1 70 LI 71 Ii 72 I _JN I 73[ I 174 751 1 1 1 1 1 1 180
Section B:Facility Data L
Name and Location of Facility Inspected(For Industrial Users discharging to POTW,also include Entry Time/Date Permit Effective Date
POTW name and NPDES permit Number) 08 OOAM 18/08/09 17/01/01
Greensboro Terminal
Exit Time/Date Permit Expiration Date
101 S Chimney Rock Rd
09 30AM 18/08/09 21/08/31
Greensboro NC 27409
Name(s)of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) Other Facility Data
///
Not Required/ORC/919-807-6353/
Name,Address of Responsible Official/Title/Phone and Fax Number
Contacted
Sam Baker,101 S Chimney Rock Rd Greensboro NC
274099661//336-299-0331/3362924494 No
Section C.Areas Evaluated During Inspection(Check only those areas evaluated)
• Permit • Flow Measurement • Records/Reports MI Self-Monitoring Program
• Facility Site Review MI Effluent/Receiving Waters
Section D:Summary of Finding/Comments(Attach additional sheets of narrative and checklists as necessary)
(See attachment summary)
Name(s)and Signature(s)of Inspector(s) Agency/Office/Phone and Fax Numbers P Date
Jennifer F Graznakckeyoix.f.4.e
WSRO WQ//336-771-5000/ r
g/I Z VC 8
Signature nagement Q A Reviewer Agency/Office/Phone and Fax Numbers Date
/4" 2.)
EPA Form 3560-3(Rev 9-94)Previous editions are obsolete.
Page# 1
NPDES yr/mo/day Inspection Type (Cont.) 1
31 NC0022209 I11 12[ 18/08/09 117 18 LI
Section D.Summary of Finding/Comments(Attach additional sheets of narrative and checklists as necessary)
I. Permit
The NPDES permit became effective January 1, 2017 and expires August 31, 2021.The facility had a
copy of the current permit available during the inspection.The treatment structures seen during the
inspection match those listed in the permit.
II. Self-Monitoring Program
A review of the monthly discharge monitoring reports(DMRs) for the period July 2017 through June
2018 showed that the facility complied with all permit limits. Regarding the permit monitoring
requirements, it was noted that all sampling was performed per the frequencies specified in the permit.
All laboratory analysis is performed by Research &Analytical Laboratories, Inc. except Acute Whole
Effluent Toxicity Testing,which is performed by Environmental Testing Solutions, Inc. Mr.Witten
collects the monthly and/or quarterly grab samples, and a representative from the laboratory picks
them up at the site.
III. Records/Reports
Mr. Witten fills out a Retention Pond Draining Report for every discharge event. Chain of custody forms
and lab data sheets are in good order.All the required monitoring was performed per the frequencies
specified in the NPDES permit. Ms. Graznak noted no data transcription discrepancies from lab sheets
to DMRs in her documentation review.
IV. Flow Measurement
The permit requires episodic flow monitoring. Flow is measured using a totalizing flow meter on the
effluent pipe. The discharge is controlled manually by a locked release valve. The flow meter was
calibrated on December 4, 2017. Flow is recorded on the Retention Pond Draining Report.
V. Operations and Maintenance
The facility appeared to be well operated and maintained. No issues were noted during the inspection.
VI. Facility Site Review
The truck loading area drains to a concrete holding pit and then is pumped to an 8,000-gallon above
ground storage tank with a hydrocarbon detector. If no hydrocarbon is detected,the water is
transferred to the secondary containment area surrounding the aboveground storage tanks. From
there, it drains to the settling pond.
VII. Effluent/Receiving Waters
The system discharges to a rip rap lined ditch just outside of the perimeter fence. The effluent
eventually reaches an unnamed tributary of Long Branch, class Water Supply IV Waters in the Cape
Fear River Basin. No effluent was being discharged on the day of the inspection.
Page# 2
'
Permit: NC0022209 Owner-Facility: Greensboro Terminal
Inspection Date: 08/09/2018 Inspection Type: Compliance Evaluation
Permit Yes No NA NE
(If the present permit expires in 6 months or less). Has the permittee submitted a new 0 0 IN 0
application?
Is the facility as described in the permit? • 0 0 0
#Are there any special conditions for the permit? 0 ❑ • 0
Is access to the plant site restricted to the general public? • 0 0 0
Is the inspector granted access to all areas for inspection? • 0 0 0
Comment: The facility had a copy of the current permit available during the inspection
Flow Measurement-Effluent Yes No NA NE
#Is flow meter used for reporting? • 0 0 0
Is flow meter calibrated annually? • 0 0 0
Is the flow meter operational? • 0 0 0
(If units are separated) Does the chart recorder match the flow meter? 0 II 0 0
Comment: Flow is measured with a totalizing meter on the effluent pipe.
Effluent Pipe Yes No NA NE
Is right of way to the outfall properly maintained? • ❑ 0 0
Are the receiving water free of foam other than trace amounts and other debris? 0 0 0 U
If effluent (diffuser pipes are required) are they operating properly? 0 0 MI 0
Comment: The system was not discharging on the day of the inspection so no effluent was observed.
Page# 3