Loading...
HomeMy WebLinkAboutNC0033430_Inspection_20180815EPA United States Environmental Protection Agency Washington, D.C. 20460 Water Compliance Inspection Report Form Approved. OMB No. 2040-0057 Approval expires 8-31-98 Section A: National Data System Coding (i.e., PCS) Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type 1 N 52 NC0033430 18/08/15 C S31112171819 20 21 66 Inspection Work Days Facility Self-Monitoring Evaluation Rating B1 QA ----------------------Reserved------------------- N67707172 73 74 75 80 Section B: Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include POTW name and NPDES permit Number) Camp Judaea WWTP US Hwy 64 E Hendersonville NC 28792 Entry Time/Date Permit Effective Date Exit Time/Date Permit Expiration Date 10:10AM 18/08/15 16/01/01 Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) /// Kevin C White/ORC/828-289-2165/ Other Facility Data 11:05AM 18/08/15 20/11/30 Name, Address of Responsible Official/Title/Phone and Fax Number Ari Kurtz,1996 Cliff Vly Wayste Atlanta GA 30329//404-634-7883/Contacted No Section C: Areas Evaluated During Inspection (Check only those areas evaluated) Permit Operations & Maintenance Sludge Handling Disposal Effluent/Receiving Waters Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s) and Signature(s) of Inspector(s)Agency/Office/Phone and Fax Numbers Date Daniel J Boss ARO WQ//828-296-4658/ Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete. Page#1 DocuSign Envelope ID: 2BFB4C65-B1D3-427C-A088-765C34E743AF 8/17/2018 8/17/2018 NPDES yr/mo/day 18/08/15 Inspection Type C3111218 1 Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) I (Daniel Boss) conducted a compliance evaluation inspection of the Camp Judaea WWTP on 8/13/2018. I met with Kevin White (ORC) for the inspection. There was no flow to the plant at the time. Mr. White said that all the campers had left about 2 weeks prior. The campground is only active for 2 months per year according to Mr. White. Overall the plant appeared to be operated and maintained well. There is evidence of some deterioration at the plant, but mostly just rust on grates and basin walls. The outfall pipe stops short of discharging into the creek by about 12 feet. There is a shallow channel that the effluent runs through into the creek from the outfall, but it's becoming filled in with sediment and should be cleared out. NC0033430 17 (Cont.) Page#2 DocuSign Envelope ID: 2BFB4C65-B1D3-427C-A088-765C34E743AF Permit:NC0033430 Inspection Date:08/15/2018 Owner - Facility: Inspection Type: Camp Judaea WWTP Compliance Evaluation Operations & Maintenance Yes No NA NE Is the plant generally clean with acceptable housekeeping? Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable Solids, pH, DO, Sludge Judge, and other that are applicable? Comment: Permit Yes No NA NE (If the present permit expires in 6 months or less). Has the permittee submitted a new application? Is the facility as described in the permit? # Are there any special conditions for the permit? Is access to the plant site restricted to the general public? Is the inspector granted access to all areas for inspection? Comment: Bar Screens Yes No NA NE Type of bar screen a.Manual b.Mechanical Are the bars adequately screening debris? Is the screen free of excessive debris? Is disposal of screening in compliance? Is the unit in good condition? Comment: Equalization Basins Yes No NA NE Is the basin aerated? Is the basin free of bypass lines or structures to the natural environment? Is the basin free of excessive grease? Are all pumps present? Are all pumps operable? Are float controls operable? Are audible and visual alarms operable? # Is basin size/volume adequate? Page#3 DocuSign Envelope ID: 2BFB4C65-B1D3-427C-A088-765C34E743AF Permit:NC0033430 Inspection Date:08/15/2018 Owner - Facility: Inspection Type: Camp Judaea WWTP Compliance Evaluation Equalization Basins Yes No NA NE There was no flow to the plant, but Mr. White turned on the air to the basin and checked the floats and alarm. Comment: Secondary Clarifier Yes No NA NE Is the clarifier free of black and odorous wastewater? Is the site free of excessive buildup of solids in center well of circular clarifier? Are weirs level? Is the site free of weir blockage? Is the site free of evidence of short-circuiting? Is scum removal adequate? Is the site free of excessive floating sludge? Is the drive unit operational? Is the return rate acceptable (low turbulence)? Is the overflow clear of excessive solids/pin floc? Is the sludge blanket level acceptable? (Approximately ¼ of the sidewall depth) There was no flow through the plant at this time, but the clarifier was still full and had no floating sludge or scum. Comment: Aeration Basins Yes No NA NE Mode of operation Ext. Air Type of aeration system Diffused Is the basin free of dead spots? Are surface aerators and mixers operational? Are the diffusers operational? Is the foam the proper color for the treatment process? Does the foam cover less than 25% of the basin’s surface? Is the DO level acceptable? Is the DO level acceptable?(1.0 to 3.0 mg/l) There was no flow, but Mr. White turned on the blowers to assess mixing and aeration.Comment: Disinfection-Tablet Yes No NA NE Are tablet chlorinators operational? Are the tablets the proper size and type? Number of tubes in use?2 Page#4 DocuSign Envelope ID: 2BFB4C65-B1D3-427C-A088-765C34E743AF Permit:NC0033430 Inspection Date:08/15/2018 Owner - Facility: Inspection Type: Camp Judaea WWTP Compliance Evaluation Disinfection-Tablet Yes No NA NE Is the level of chlorine residual acceptable? Is the contact chamber free of growth, or sludge buildup? Is there chlorine residual prior to de-chlorination? Comment: De-chlorination Yes No NA NE Type of system ?Tablet Is the feed ratio proportional to chlorine amount (1 to 1)? Is storage appropriate for cylinders? # Is de-chlorination substance stored away from chlorine containers? Comment: Are the tablets the proper size and type? Are tablet de-chlorinators operational? Number of tubes in use?2 Comment: Effluent Pipe Yes No NA NE Is right of way to the outfall properly maintained? Are the receiving water free of foam other than trace amounts and other debris? If effluent (diffuser pipes are required) are they operating properly? The outfall pipe was partially filled with sediment and the channel from the outfall to the creek has excessive sediment built up. This channel should be kept clear of debris and sediment. Comment: Aerobic Digester Yes No NA NE Is the capacity adequate? Is the mixing adequate? Is the site free of excessive foaming in the tank? # Is the odor acceptable? # Is tankage available for properly waste sludge? The digester was empty.Comment: Page#5 DocuSign Envelope ID: 2BFB4C65-B1D3-427C-A088-765C34E743AF