Water Compliance Inspection Report
Form Approved.
OMB No. 2040-0057
Approval expires 8-31-98
Section A: National Data System Coding (i.e., PCS)
Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type
1 N 52 NC0087106 18/08/14 C S31112171819 20
21 66
Inspection Work Days Facility Self-Monitoring Evaluation Rating B1 QA ----------------------Reserved-------------------
N67707172 73 74 75 80
Section B: Facility Data
Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include
POTW name and NPDES permit Number)
Champion Hills WWTP
Champion Hills WWTP
Hendersonville NC 28739
Entry Time/Date Permit Effective Date
Exit Time/Date Permit Expiration Date
09:00AM 18/08/14 16/01/01
Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s)
///
Danielle Ann Hunter/ORC/828-697-0063/
Other Facility Data
01:00PM 18/08/14 20/11/30
Name, Address of Responsible Official/Title/Phone and Fax Number
Craig Galloway,1 Hagen Dr Hendersonville NC 28739/Director of Grounds &
Facilities/828-696-1662/8286962097
Contacted
No
Section C: Areas Evaluated During Inspection (Check only those areas evaluated)
Permit Flow Measurement Operations & Maintenance Self-Monitoring Program
Sludge Handling Disposal Effluent/Receiving Waters
Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary)
(See attachment summary)
Name(s) and Signature(s) of Inspector(s)Agency/Office/Phone and Fax Numbers Date
Daniel J Boss ARO WQ//828-296-4658/
Beverly Price Division of Water Quality//828-296-4500/
Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date
EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete.
Page#1
DocuSign Envelope ID: ECBA9C32-B2E2-40E4-8504-F6821657E714
8/22/2018
8/22/2018
8/22/2018
NPDES yr/mo/day
18/08/14
Inspection Type
C3111218
1
Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary)
Beverly Price and I (Daniel Boss) conducted a compliance evaluation inspection of the Champion Hills
WWTP on 8/14/2018. We met with Danielle Hunter (ORC), Juanita James (Backup ORC), and Craig
Galloway (Grounds Manager) for the inspection. The plant appeared to be functioning okay (the effluent
looked fairly clear), although there were high blankets in the clarifiers and some pin floc coming over
the weirs.
The two items of greatest concern at this facility are the tertiary filters and the effluent sampling. The
backwash operations are non-functional for both filters. This results in much of the wastewater simply
bypassing the filters. The composite sampling is not flow proportional as required by the permit. The
effluent composite sampling point is currently in the chlorine contact chamber. According to the
permit, the effluent sampling needs to take place beyond all treatment units. In this case, that would be
beyond the dechlorinator.
NC0087106 17 (Cont.)
Page#2
DocuSign Envelope ID: ECBA9C32-B2E2-40E4-8504-F6821657E714
Permit:NC0087106
Inspection Date:08/14/2018
Owner - Facility:
Inspection Type:
Champion Hills WWTP
Compliance Evaluation
Operations & Maintenance Yes No NA NE
Is the plant generally clean with acceptable housekeeping?
Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable
Solids, pH, DO, Sludge Judge, and other that are applicable?
Comment:
Permit Yes No NA NE
(If the present permit expires in 6 months or less). Has the permittee submitted a new
application?
Is the facility as described in the permit?
# Are there any special conditions for the permit?
Is access to the plant site restricted to the general public?
Is the inspector granted access to all areas for inspection?
Comment:
Pump Station - Influent Yes No NA NE
Is the pump wet well free of bypass lines or structures?
Is the wet well free of excessive grease?
Are all pumps present?
Are all pumps operable?
Are float controls operable?
Is SCADA telemetry available and operational?
Is audible and visual alarm available and operational?
Comment:
Bar Screens Yes No NA NE
Type of bar screen
a.Manual
b.Mechanical
Are the bars adequately screening debris?
Is the screen free of excessive debris?
Is disposal of screening in compliance?
Is the unit in good condition?
A screening basket is used in addition to the bar screen.Comment:
Page#3
DocuSign Envelope ID: ECBA9C32-B2E2-40E4-8504-F6821657E714
Permit:NC0087106
Inspection Date:08/14/2018
Owner - Facility:
Inspection Type:
Champion Hills WWTP
Compliance Evaluation
Equalization Basins Yes No NA NE
Is the basin aerated?
Is the basin free of bypass lines or structures to the natural environment?
Is the basin free of excessive grease?
Are all pumps present?
Are all pumps operable?
Are float controls operable?
Are audible and visual alarms operable?
# Is basin size/volume adequate?
Facility is currently using air lift pumps in place of submersible pumps. The level in the EQ
basin is kept high for the airlift pumps, limiting the ability to mitigate high flows.
Comment:
Aeration Basins Yes No NA NE
Mode of operation Ext. Air
Type of aeration system Diffused
Is the basin free of dead spots?
Are surface aerators and mixers operational?
Are the diffusers operational?
Is the foam the proper color for the treatment process?
Does the foam cover less than 25% of the basin’s surface?
Is the DO level acceptable?
Is the DO level acceptable?(1.0 to 3.0 mg/l)
Last settleable solids measurements 60% and 40%.
AB#1- D.O.=2.02 mg/L, pH=6.76
AB#2- D.O.=3.08 mg/L, pH=6.56
Comment:
Secondary Clarifier Yes No NA NE
Is the clarifier free of black and odorous wastewater?
Is the site free of excessive buildup of solids in center well of circular clarifier?
Are weirs level?
Is the site free of weir blockage?
Is the site free of evidence of short-circuiting?
Is scum removal adequate?
Is the site free of excessive floating sludge?
Is the drive unit operational?
Is the return rate acceptable (low turbulence)?
Page#4
DocuSign Envelope ID: ECBA9C32-B2E2-40E4-8504-F6821657E714
Permit:NC0087106
Inspection Date:08/14/2018
Owner - Facility:
Inspection Type:
Champion Hills WWTP
Compliance Evaluation
Secondary Clarifier Yes No NA NE
Is the overflow clear of excessive solids/pin floc?
Is the sludge blanket level acceptable? (Approximately ¼ of the sidewall depth)
There was substantial pin floc and the blankets measured approximately 11' out of 12.5'
depth.
Comment:
Filtration (High Rate Tertiary)Yes No NA NE
Type of operation:Down flow
Is the filter media present?
Is the filter surface free of clogging?
Is the filter free of growth?
Is the air scour operational?
Is the scouring acceptable?
Is the clear well free of excessive solids and filter media?
The filters backwash operations are not working, and consequently much of the wastewater
is bypassing the tertiary filters. Pump #1 was not working and Pump #2 needs a reverse
thread coupling.
Comment:
Disinfection-Tablet Yes No NA NE
Are tablet chlorinators operational?
Are the tablets the proper size and type?
Number of tubes in use?4
Is the level of chlorine residual acceptable?
Is the contact chamber free of growth, or sludge buildup?
Is there chlorine residual prior to de-chlorination?
Comment:
De-chlorination Yes No NA NE
Type of system ?Tablet
Is the feed ratio proportional to chlorine amount (1 to 1)?
Is storage appropriate for cylinders?
# Is de-chlorination substance stored away from chlorine containers?
Comment:
Are the tablets the proper size and type?
Are tablet de-chlorinators operational?
Page#5
DocuSign Envelope ID: ECBA9C32-B2E2-40E4-8504-F6821657E714
Permit:NC0087106
Inspection Date:08/14/2018
Owner - Facility:
Inspection Type:
Champion Hills WWTP
Compliance Evaluation
De-chlorination Yes No NA NE
Number of tubes in use?4
Comment:
Aerobic Digester Yes No NA NE
Is the capacity adequate?
Is the mixing adequate?
Is the site free of excessive foaming in the tank?
# Is the odor acceptable?
# Is tankage available for properly waste sludge?
There is a crack in the digester wall that is shared with the equalization basin. This needs to
be repaired.
Comment:
Effluent Sampling Yes No NA NE
Is composite sampling flow proportional?
Is sample collected below all treatment units?
Is proper volume collected?
Is the tubing clean?
# Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees
Celsius)?
Is the facility sampling performed as required by the permit (frequency, sampling type
representative)?
Samples are being collected from the chlorine contact chamber when they should be taken
from a location past all treatment units. Ms. Hunter said that she does collect fecal coliform
samples from the outfall for the NPDES permit.
Comment:
Effluent Pipe Yes No NA NE
Is right of way to the outfall properly maintained?
Are the receiving water free of foam other than trace amounts and other debris?
If effluent (diffuser pipes are required) are they operating properly?
Comment:
Flow Measurement - Effluent Yes No NA NE
# Is flow meter used for reporting?
Is flow meter calibrated annually?
Is the flow meter operational?
Page#6
DocuSign Envelope ID: ECBA9C32-B2E2-40E4-8504-F6821657E714
Permit:NC0087106
Inspection Date:08/14/2018
Owner - Facility:
Inspection Type:
Champion Hills WWTP
Compliance Evaluation
Flow Measurement - Effluent Yes No NA NE
(If units are separated) Does the chart recorder match the flow meter?
Comment:
Pump Station - Effluent Yes No NA NE
Is the pump wet well free of bypass lines or structures?
Are all pumps present?
Are all pumps operable?
Are float controls operable?
Is SCADA telemetry available and operational?
Is audible and visual alarm available and operational?
Comment:
Standby Power Yes No NA NE
Is automatically activated standby power available?
Is the generator tested by interrupting primary power source?
Is the generator tested under load?
Was generator tested & operational during the inspection?
Do the generator(s) have adequate capacity to operate the entire wastewater site?
Is there an emergency agreement with a fuel vendor for extended run on back-up power?
Is the generator fuel level monitored?
This is a natural gas powered generator.Comment: